Loading...
HomeMy WebLinkAbout2850 GAZELLE CT; ; CBC2022-0325; PermitBuilding Permit Finaled (cityof Carlsbad Commercial Permit Print Date: 06/14/2024 Job Address: 2850 GAZELLE CT, CARLSBAD, CA 92010 Permit No: Status: CBC2022-0325 Closed -Finaled Permit Type: BLDG-Commercial Work Class: Tenant Improvement Parcel#: 2091202700 Track#: Valuation: $235,689.96 Lot#: Occupancy Group: A & B Project#: #of Dwelling Units: Plan #: Bedrooms: Bathrooms: Occupant Load: 200 Code Edition: 2019 Sprinkled: Yes Project Title: Construction Type: II-A Orig. Plan Check#: Plan Check#: Applied: 08/31/2022 Issued: 01/10/2023 Finaled Close Out: 06/14/2024 Final Inspection: 04/27/2023 INSPECTOR: Dreibelbis, Peter Alvarado, Tony Kersch, Tim Description: IONIS: COM-Tl (4,089 SF) REMODEL LARGE CONFRENCE ROOM TO SMALLER CONFERENCE ROOMS AND STORAGE Applicant: DGA ARCHITECTS JON OHLSON 2550 5TH AVE, # STE 115 SAN DIEGO, CA 92103-6615 FEE BUILDING PLAN CHECK Property Owner: IONIS GAZELLE LLC 2855 GAZELLE CT CARLSBAD, CA 92010-6670 (760) 603-2582 BU ILDING PLAN REVIEW -MINOR PROJECTS (LDE) BU ILDING PLAN REVIEW -MINOR PROJECTS (PLN) CERTIFICATE OF OCCUPANCY COMM/IND Tl -NON-STRUCTURAL FIRE A-2 & A-3 Occupancies -Tl SB1473 -GREEN BUILDING STATE STANDARDS FEE STRONG MOTION -COMMERCIAL (SMIP) Total Fees: $3,467.45 Total Payments To Date: $3,467.45 Contractor: GOOD AND ROBERTS INC 2455 IMPALA DR CARLSBAD, CA 92010-7227 Balance Due: AMOUNT $887.77 $194.00 $98.00 $16.00 $1,451.69 $744.00 $10.00 $65.99 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov V .. (_ City of ~arlsbad ,dress 2050 Gazelle Court. Carlsbad, CA 92010 it Name ti: lonis Pharmaceuticals, Inc Built: 2020 ---Occupancy: A & 6 COMMERCIAL BUILDING PERMDT APPLICATION B-2 C-ec,z.o~z. .. o 3~ Plan Checl< Est. Value .f 2.ss-; t,9't. 'lb PC Deposit I\ ~ 77 • 77 Date -.,hs,--z..o~"Z.- Suite: APN: 209-120-20-00 , ____ _, Lot ti: Vear Built: 2020 ,____ ---------- Construction Type:_11A __ Fire sprinlders 0 YESQ NO A/C:QYES()NO ,Ef DESCRIPTION OF WORK: Interior Tenant Improvement& consisting of converting 4,089 square leet ol oxisling conloronce space into smaller ,nferenco rooms and storage space. Ll Addltion/New: ____________ New SF and Use, __________ New SF and Use ______ SF Deck, SF Patio Cover, SF Other (Specify) ___ _ [ii Tenant Improvement: _____ SF, Existing Use: _______ Proposed Use: ______ _ _4._oo_9 ____ SF, Existing Use: Conforencel1ooms Proposed Use: Conleronc:oAooms D Other: _________ "'--_..;.."o_l,_-.-. __ l_-c. __ __;:~,,___l?_°=l_•_=l__._P __________ _ PRIMARY APPLICANT ,·• Name: Jon Ohlson Address: 2550 Filth Ave. City: San Diogo Phone: 619-820-4021 Email: johlson@dga-sd.com DESIGN PROFESSIONAL State:._c_A ____ Zip:92103 Name: Jon Ohlson, AIA, C/O DGA Archllects Address: 2550 Flllh Ave. <::lty: San Diego Phone: 619.820.4021 State:_c_A __ .Zip: o21 oa PROPERTY OWNER Name: lonls Pharmaceullcals, Inc. -rJo Wayne Sanders Address: 2855 Gazelle Court City: Carlsbad Phone: 760.931.9200 Email: wsanders@lonlsph.com State:_c_A __ .Zlp: 92010 CONTRACTOR OF RECORD Business Name:-"000A Robed& 11 c Address~6,lss;pela o,1,e City: e,_ I I J Phone: '6eo61le"i'atit State~ Zip:_9_28_18 _____ _ Emall: johlson@doa-sd.com Email~g11,o.cu:: LI.. Architect State license: _c_-2_22_9_1 _________ CSLB License#: '.39,l ! j5' Class: _____ 1> _______ _ Carlsbad Business License# (Required): (3L-N R,@) /4:1-12.-20 ]~ APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information ts correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. ~~:~:::~~c:!,:b-:.-~-,:-9-~-::-:-s_o_n _____ P_h:-44_2 __ ,,,:;:N(Yt bA Email: Bulhtloo@carlsl>pc/siJ,t:0V REV. 04/22 THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECI< NUMBER: ______ _ A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE. {OPTION A): LICENSED CONTRACTOR DECLARATION: lherebyafflrmunderpena/tyofper)urythatlamlicensedunderprovisionsofChapter9(commencingwithSection7000)ofDivision3 of the Business and Professions Code, and my license is inf ul/ force and ef feet. I a/soaffirm under penalty of perjury one of the following declarations (CHOOSE ONE): 01 have and will maintain a certificate of consent to self-Insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit Is Issued. PollcyNo. ____________________________________ _ m;~:~ and wlll maintain work. er's compensation, as required by Section 3700 of the Labor Code, for the p forman o the work for which this ~ workers' comp_ersatlon Insurance carrier and pollcy number are: Insurance Company Name: V ' Polley No. 5 ':t 2 ( 0 ,:> D 5 E><piratlon Date: __,_~0~-"-'-<~-=~:£..:..-L----- -OR- O certlficate of Exemption: I certify that In the performance of the work for which this permit Is Issued, I shall not employ any person In any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage Is unlawful and shall subject an employer to criminal penalties and clvll fines up to $100,000.00, In addition the to the cost of compensation, damages as provided for In Section 3706 of the Labor Code, Interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there Is a construction lending agency for the performance of the work this permit Is Issued (Sec. 3097 (I) Civil Code). Lender's Name: ___________________ Lender's Address: ___________________ _ CONTRACTOR CERTIFICATION: /certify that I have read the applicationandstate that the above information is correct and that the informatlonon the plans ls accurate. /agree to comply with all City ordinances and State laws relating to building construction. Note: If the person signing above Is an authorized agent for the contractor provide a I -OR - (OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: n I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure Is not Intended or offered for sale (Sec. ~44, Business and Professions Code: The Contractor's Lkense Law does not apply to an owner of property who builds or Improves thereon, and who does such work himself or through his own employees, provided that such Improvements are not Intended or offered for sale. If, however, the building or improvement Is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or Improve for the purpose of sale). -OR- D1, as owner of the property, am exclusively contracting with llcensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and contracts for such projects with contractor(s) lkensed pursuant to the Contractor's License Law). -OR-□1 am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: AND, D FORM B-61 "Owner Builder Acknowledgement and Verification Form" Is required for any permit Issued to a property owner. By my signature below I acknowledge that, except for my personal residence In which I musl have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder If It has not been constructed In Its entirety by licensed contractors./ understand that ocopy af the appl /cable law, Section 7044 of the Business and Praf essions Code, Is ava/loble upon request when this application is submitted arat the following Web site: http://www.leginfo.ca.gov/calaw.html. OWNER CERT/FICA TION: /certify that I have read the application and state that the above information is correct and that the Information on the plans Is accurate. /agree to comply with all City ordinances and State laws relating to building construction. NAME (PRINT): ________ _ SIGN: _________ DATE: _____ _ Note: If the person signing above Is an authorized agent for the property owner Include form B-62 signed by property owner. 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Fax: 760-602-8558 Email: Bullding@carlsbadca.gov 2 REV. 07/21 Building Permit Inspection History Finaled {cityof Carlsbad PERMIT INSPECTION HISTORY for (CBC2022-0325) Permit Type: BLDG-Commercial Application Date: 08/31/2022 Owner: IONIS GAZELLE LLC Work Class: Tenant Improvement Issue Date: 01/10/2023 Subdivision: PARCEL MAP NO 21705 Status: Closed -Finaled Expiration Date: 09/18/2023 Address : 2850 GAZELLE CT IVR Number: 43029 CARLSBAD, CA 92010 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 01/11/2023 01/11/2023 BLDG-44 200451-2023 Passed Tim Kersch Complete Rough/Ducts/Dampers Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01/12/2023 01/12/2023 BLDG-17 Interior 200588-2023 Passed Tim Kersch Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Dry partially. Ok for second. Yes 01/23/2023 01/23/2023 BLDG-84 Rough 201191-2023 Passed Tim Kersch Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 01 /25/2023 01/25/2023 BLDG-1 6 lnsulatlon 201446-2023 Passed Tim Kersch Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01/30/2023 01/30/2023 BLDG-17 Interior 201757-2023 Passed Tim Kersch Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 02/02/2023 02/02/2023 BLDG-17 Interior 202128-2023 Partial Pass Tony Alvarado Reinspectlon Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Drywall lower sections vertical wall Yes partitions -OK. 03/03/2023 03/03/2023 BLDG-31 204638-2023 Passed Peter Dreibelbis Complete Underground/Conduit - Wiring Checklist Item COMMENTS Passed BLDG-Building Deficiency Conduit Ok No Friday, June 14, 2024 Page 1 of 3 PERMIT INSPECTION HISTORY for {CBC2022-0325) Permit Type: BLDG-Commercial Application Date: 08/31/2022 Owner: IONIS GAZELLE LLC Work Class: Tenant Improvement Issue Date: 01/10/2023 Subdivision: PARCEL MAP NO 21705 Status: Closed -Finaled Expiration Date: 09/18/2023 Address: 2850 GAZELLE CT IVR Number: 43029 CARLSBAD, CA 92010 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection Date Start Date Status NOTES Created By TEXT Created Date Angie Teanio 714-906-1135 Randy 03/02/2023 BLDG-34 Rough 204635-2023 Passed Peter Dreibelbis Complete Electrlcal Checklist Item COMMENTS Passed BLDG-Building Deficiency Conduit ok No NOTES Created By TEXT Created Date Angie Teanio 714-906-11 35 Randy 03/02/2023 03/06/2023 03/06/2023 BLDG-12 Steel/Bond 204741-2023 Passed Tim Kersch Complete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes NOTES Created By TEXT Created Date Becky Falk RANDY 714-906-1135 03/03/2023 03/21/2023 03/21/2023 BLDG-85 T-Bar, Celling 205884-2023 Passed Tim Kersch Complete Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers NOTES Created By TEXT Created Date Angie Teanio 714-906-1 135 Randy 03/20/2023 04/11/2023 04/11/2023 BLDG-Flnal Inspection 207679-2023 Partial Pass Tim Kersch Relnspectlon Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency List for final. No BLDG-Plumbing Final Yes BLDG-Mechanical Final No BLDG-Structural Final Yes BLDG-Electrical Final No NOTES Created By TEXT Created Date Angie Teanio 714-906-1135 Randy II Pre-final walk thru 04/10/2023 04/27/2023 04/27/2023 BLDG-Final Inspection 209250-2023 Passed Tim Kersch Complete Friday, June 14, 2024 Page 2 of 3 PERMIT INSPECTION HISTORY for (CBC2022-0325) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Closed -Finaled Application Date: 08/31/2022 Owner: IONIS GAZELLE LLC Issue Date: 01/10/2023 Subdivision: PARCEL MAP NO 21705 Expiration Date: 09/18/2023 IVR Number: 43029 Address: 2850 GAZELLE CT CARLSBAD, CA 92010 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Frida~June 1~2024 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final NOTES Created By Angie Teanio Angie Teanio Status COMMENTS List for final. TEXT 714-906-11 35 Randy II Pre-final walk thru 714-906-1135 Randy Passed Yes Yes Yes Yes Yes Created Date 04/10/2023 04/26/2023 Page 3 of 3 MBO Inc. 4830 Viewridge Ave, Suite A San Diego, CA 92123 (858) 751-5702 www.mbol.com Ion is Conference Center 1st Floor MB0.2839 Prepared for: Jake Lopez Issued: Apex Mechanical Systems, Inc. 7440 Trade Street, Suite A, 4.25.2023 San Diego, CA 92121 Jlopez@apexmech.com CERTIFICATION# 3306 NEBB CERTIFIED TESTING, ADJUSTING & BALANCING REPORT PROJECT NAME: Ion is Conference Center 1st Floor PROJECT ADDRESS: 2850 Gazelle Court Carlsbad, CA 92010 ENGINEER: exp. 5670 Oberlin Drive, San Diego, CA 92121 HVAC CONTRACTOR: Apex Mechanical Systems, Inc. 7440 Trade Street, Suite A, San Diego, CA 92121 NEBB CONTRACTOR: MBO, Inc. 4619 Viewridge Ave. Suite C San Diego, CA 92123 MBO JOB NUMBER: MBO.2839 NATIONAL ENVIRONMENTAL BALANCING BUREAU NEBB CERTIFICATION PAGE PROJECT: Ion is Conference Center 1st Floor ADDRESS: 2850 Gazelle Court Carlsbad CA 92010 CERTIFICATION # 3306 MBO JOB NO.: MBO.2839 ~~-'=;;;;..;;;..;;;;..._ _______________________ _ THE DATA PRESENTED IN THIS REPORT IS AN EXACT RECORD OF SYSTEM PERFORMANCE AND WAS OBTAINED IN ACCORDANCE WITH NEBB STANDARD PROCEDURES. ANY VARIANCES FROM DESIGN QUANTITIES WHICH EXCEED NEBB TOLERANCES ARE NOTED THROUGHOUT THIS REPORT. THE AIR DISTRIBUTION SYSTEMS HAVE BEEN TESTED & BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH NEBB "PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, BALANCING OF ENVIRONMENTAL SYSTEMS" AND THE PROJECT SPECIFICATIONS. NEBB TAB FIRM: MBO, Inc. REG. NO.: 3306 CERTIFIED BY: Dawayne Trobaugh DATE: 04.25.2023 THE HYDRONIC DISTRIBUTION SYSTEMS HAVE BEEN TESTED & BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH NEBB "PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, BALANCING OF ENVIRONMENTAL SYSTEMS" AND THE PROJECT SPECIFICATIONS. NEBB TAB FIRM: MBO, Inc. REG. NO.: 3306 CERTIFIED BY: Dawayne Trobaugh DATE: N/A ...:...:.;...:.....:.... ____ _ ---- SUBMITTED AND CERTIFIED BY: NEBB TAB FIRM:_M_B_O.:.., l_n_c. ___ _ REG. NO.: 3306 ------- TAB SUPERVISOR: Dawayne Trobaugh SIGNATURE/ DATE: DAWAYNE C. TROBAUGH CERTIFICATION Dawayne Trobau 3306 Exp. 3/31/24 dron· Dig' ally signed by 0awayne Trobaugh w. ~-C-US, E•dtrobaugh@mbo1.com, 111 Oi-'):'BO Inc., CN•Dawayne Trobaugh Date: 2023.04.25 21 :33:08·07'00' '------------------------1 NATIONAL ENVIRONMENTAL BALANCING BUREAU +--· -------t ' l 8l ·-50 Ez -- i 111 11 111 11 rn, i I ~~ 11111 1111111 H i ~ * I +:-i- 1 I i I ' I ' -+ r --____ , AIR DISTRIBUTION TEST SHEET TEST DATE: SYSTEM: 24-Jan-2023 ZONEDVAVs TAB SUPERVISOR: Dawayne Trobaugh TAB TECH: Micah Daley LOCATION: 1ST FLOOR TERMINAL K -DESIGN PRELIM TERMINAL NUMBER ROOM NUMBER TYPE SIZE VAV-303-Dl-Zl-Sl CONFERENCE E136 CD 12"0 VAV-303-Dl-Zl-S2 CONFERENCE El36 CD 12"0 VAV-303-Dl-Zl-S3 CIRCULATION El41 CD 8"0 VAV-303-Dl-Zl-S4 CIRCULATION El41 CD 8"0 TOTAL VAV-303-D2-Zl-S1 STORAGE E137 CD VAV-303-D2-Z2-Sl PHONEE138 CD 6"0 VAV-303-D2-Z2-S2 PHONE El39 CD 6"0 VAV-303-D2-Z2-S3 PHONE El40 CD 6"0 TOTAL COMMENTS VAV-3-3 MEASURED 1312 CFM, BMS READING 1320. K-FACTOR 1.95 AHU STATIC PRESSURE: 0.72" VAV-303 DAMPER: 69% VAV-303 STATIC PRESSURE 0.37" DUCT 1 D-1 CONFERENCE 100% DUCT 2 ZONE 1 PHONE ROOMS 100% DUCT 2 ZONE 2 STORAGE 60% FACTOR 1 1 1 1 1 1 1 1 COMMENTS MIN VAV-3-3 MEASURED 1312 CFM, BMS READING 1320. K-FACTOR 1.95 AHU STATIC PRESSURE: 0.72" VAV-303 DAMPER: 27.5% VAV-303 STATIC PRESSURE 0.37" DUCT 1 D-1 CONFERENCE 45% DUCT2ZONE1PHONEROOMS30% DUCT 2 ZONE 2 STORAGE 0% CFM 340 340 170 170 1020 170 50 50 50 320 DUCT 2 ZONE 2 UNABLE TO READ INDIVIDUAL REGISTERS, TOTAL FLOW WAS MEASURED CERTIFIED MEMBER · NATIONAL ENVIRONMENTAL BALANCING BUREAU CFM 334 417 117 118 986 187 80 82 98 447 FINAL CFM FINAL MIN MAX % 91 325 96% 84 317 93% 40 174 102% 44 175 103% 259 991 97% 0 163 96% • 55 110% • 53 106% . 50 100% 47 321 100% AIR DISTRIBUTION TEST SHEET TEST DATE: SYSTEM: 24-Jan-2023 ZONEDVAVs TAB SUPERVISOR: Dawayne Trobaugh TAB TECH: Micah Daley LOCATION: 1st FLOOR TERMINAL TERMINAL NUMBER ROOM NUMBER TYPE SIZE VAV-302-Dl-Sl CONFERENCE E144 CD 14"0 VAV-302-D2-Sl CONFERENCE El42 CD 10"0 VAV-302-D2-S2 CONFERENCE El42 CD 10"0 TOTAL COMMENTS VAV-3-3 MEASURED 974 CFM, BMS READING 992. K-FACTOR 2.24 AHU STATIC PRESSURE: 0.72" VAV-302 DAMPER: 53.3 VAV-302 STATIC PRESSURE 0.57 DAMPER 1 POSITION 100% DAMPER 2 POSITION 55% K- FACTOR COMMENTS MIN VAV-3-3 MEASURED 1312 CFM, BMS READING 1320. K-FACTOR 2.24 AHU STATIC PRESSURE: 0.72" VAV-302 DAMPER: 99% VAV-302 STATIC PRESSURE 0.53 DAMPER 1 POSITION 38% DAMPER 2 POSITION 22% DESIGN PRELIM CFM CFM 240 204 240 218 490 574 970 996 CERTIFIED MEMBER-NATIONAL ENVIRONMENTAL BALANCING BUREAU FINALCFM FINAL MIN MAX % 96 223 93% 104 244 102% 97 507 103% 297 974 100% AIR DISTRIBUTION TEST SHEET TEST DATE: SYSTEM: 24-Jan-2023 ZONEDVAVs TAB SUPERVISOR: Dawayne Trobaugh TAB TECH: Micah Daley LOCATION: 1st FLOOR TERMINAL K- TERMINAL NUMBER ROOM NUMBER TYPE SIZE FACTOR VAV-301-Sl CONFERENCE 110 CD 14"0 VAV-301-S2 CONFERENCE 110 CD 14"0 VAV-301-S3 CONFERENCE 110 CD 14"0 VAV-301-S4 CONFERENCE 110 CD 14"0 VAV-301-SS CONFERENCE 110 CD 14"0 VAV-301-S6 CONFERENCE 110 CD 14"0 TOTAL COMMENTS VAV-3-3 MEASURED 2307 CFM, BMS READING 2232 CFM . K-FACTOR 2.03 AHU STATIC PRESSURE: 0.72" VAV-301 DAMPER: 89.8% 1 1 1 1 1 1 DESIGN PRELIM CFM CFM 385 0 375 0 375 0 385 445 375 654 375 689 2270 1788 CERTIFIED MEMBER-NATIONAL ENVIRONMENTAL BALANCING BUREAU FINAL CFM FINAL MIN MAX % 132 380 99% 127 387 103% 135 404 108% 139 400 104% 121 377 101% 124 359 96% 778 2307 102% p; -;;;:;;;;;("1iiii;;;;;;;n:=:::1 ABBREVIATIONS PAGE ---· AC AH AHU AMS ATM AVG BHP BMS CD CFM DIFF EA EF EG FPM GPM HP Hz MAU Misc. NA NEBB NS NT OSA QTY RH RPM SA SWD TAB VAV VFD = Air Conditioning Unit = Air Handler = Air Handling Unit = Air Monitoring Station = Atmosphere = Average = Brake Horsepower = Building Management System = Ceiling Diffuser = Cubic Feet per Minute = Differential = Exhaust Air = Exhaust Fan = Exhaust Grill = Feet per Minute = Gallonsper Minute = Horsepower = Hertz = Make-up Air = Miscelaneous = Not Accesible = National Environmental Balancing Bureau = Not Specified = Not Tested = Outside Air = Quantity = Reheat = Revolutions per Minute = Supply Air = Side Wall Diffuser = Testing, Adjusting, and Balancing = Variable Air Volume = Variable Frequency Drive CERTIFIED MEMBER -NATIONAL ENVIRONMENTAL BALANCING BUREAU .. I) ,; >I.,, ~ '".~ ,. I ' 'pl ,. I• _.. ·. ... ,,""" .-.._ " -. ·•·c~"n i•':i"' •• .,..· '·:~,.. ·--.'..~~~: .. ->·· ""~ hi •f\V:'• "\\••l ,1 ~"-"' ~1111 ' .,, ,,, • \\"-''-- n,#11wu11~~~ • jftrm Certtftcatton MBO, INC. HAS MET ALL REQUIREMENTS FOR NEBB CERTIFIED STATUS IN THE FOLLOWING DISCIPLINE Testing, Adjusting and Balancing of Environmental Systems 3306 NEBB Certification Number March 31, 2024 Expiration Date <!Certif itation DAW A YNE C. TROBAUGH HAS MET ALL REQUIREMENTS FOR NEBB CERTIFIED PROFESSIONAL STATUS IN THE FOLLOWING DISCIPLINE Testing, Adjusting and Balancing of Environmental Systems This Certificate, as well as individual affiliation with a NEBB Certified Firm and associated NEBB Certification Stamp are REQUIRED to provide a NEBB Certified Report. Participation in the NEBB Quality Assurance Program requires the Certificant be affiliated with a NEBB Certified Firm CP-23715 NEBB Certification Number March 31, 2024 Expiration Date ettrtification PETER MICHAEL GARCIA HAS MET ALL REQUIREMENTS FOR NEBB CERTIFIED TECHNICIAN STATUS IN THE FOLLOWING DISCIPLINE Testing, Adjusting and Balancing of Environmental Systems This Certificate, as well as individual affiliation with a NEBB Certified Firm and associated NEBB Certification Stamp are REQUIRED to provide a NEBB Certified Report. Participation in the NEBB Quality Assurance Program requires the Certificant be affiliated with a NEBB Certified Firm CT-21848 NEBB Certification Number ~Pr dent December 31, 2023 Expiration Date dxu~ NEBB President-Elect AIRDATA MULTIMETER CERTIFICATE OF CALIBRATION Customer ID: a I '3' 5 0 .3 S/N: r:1 -z_ z 5 7 6 Customer: t1 B O I J;N C , City:5A~ DI£ fro State: LA Model#: AD n-'i5' 6 0 C PO#:. ________ Calibration Due Date:. ______ Order#: 2 3 011 l Rh 2 Y % Ambient Temperature 7 O °F Barometric Pressure Z <g' • 6q in Hg ABSOLUTE PRESSURE TEST (in Hg) TEST METER TOLERANCE = :t 2 .0 % :t .1 in Hg Pressure Standard: Heise #12A-R SIN: 45605148491 Pressure Standard: Heise #02-R SIN: 41741142451 Pressure Standard: Heise #04-R SIN: 41743142453 Pressure Standard: Heise #06-R SIN: 41742/42452-1 Pressure Standard: Heise #08-R SIN: 42186143328 Pressure Standard: Heise #10-R SIN: 42203143352 Pressure Standard: Heise #14-R SIN: 43412/45043-2 __ _ Pressure Standard: Heise #16-R SIN: 43413145044 Pressure Standard: Heise #18-R SIN: 44581146845 Pressure Standard: Heise #20-R SIN: 44582/46847 A rox Set Point Standard Test Meter % Diff 14.0 3 -, 7 ' 28.4 zg-, g 3g 40.0 0 ,3 7 DIFFERENTIAL PRESSURE TEST (in we) TEST METER TOLERANCE= :t 2 .0 % :t 0.001 in we Pressure Standard: Heise #01-L SIN: 41739142449 Pressure Standard: Heise #01-R SIN: 41739142446 Pressure Standard: Heise #02-L SIN: 41741142454 Pressure Standard: Heise #03A-L SIN: 45570148461 Pressure Standard: Heise #03A-R SIN: 45570148460 Pressure Standard: Heise #04-L SIN: 41743142456 Pressure Standard: Heise #05-L SIN: 41740142450 Pressure Standard: Heise #05-R SIN: 41740142447 Pressure Standard: Heise #06-L SIN: 41742/42455 Pressure Standard: Heise #07-L SIN: 42185142186 Pressure Standard: Heise #07-R SIN: 42185143326 Pressure Standard: Heise #08-L SIN: 42186143329 Pressure Standard: Heise #09-L SIN: 42202/43351 Pressure Standard: Heise #09-R SIN: 42202/43350 Pressure Standard: Heise #10-L SIN: 42203143353 Approx Set Point Standard ✓ ✓ ✓ .0500 0 501... .1250 , 17. 67 .2250 . 'L25o 1.000 Looi 2.000 Z,017 3.600 3 .614 4.400 4,405 27.00 27,02 50.00 jo, oL/ Over Pressure NA Pressure Standard: Heise #11-L SIN: 43165144551-1 Pressure Standard: Heise #11-R SIN: 43165144730 Pressure Standard: Heise #12A-L SIN: 45605148490-1 Pressure Standard: Heise #13-L SIN: 43415145041 Pressure Standard: Heise #13-R SIN: 43415145039 Pressure Standard: Heise #14-L SIN: 43412/45045 Pressure Standard: Heise #15-L SIN: 43416145042 Pressure Standard: Heise #15-R SIN: 43416145040-1 Pressure Standard: Heise #16-L SIN: 43413145046 Pressure Standard: Heise #17-L SIN: 44579146842 Pressure Standard: Heise #17-R SIN: 44579146841 Pressure Standard: Heise #18-L SIN: 44581146846 Pressure Standard: Heise #19-L SIN: 44580146844 Pressure Standard: Heise #19-R SIN: 44580146843 Pressure Standard: Heise #20-L SIN: 44582/46848 Test Meter % Diff ,r'J50o -. ~o , I 2-5C/ -• ZLj 7.:2. s I .04 I, 007 -. lo L, O I 'i -,10 3,607 -. J 'J Lj, l\ 13 1'6 2 7, ( o , '3r) 50,06 4 O<-i / NA Shortridge Instruments, Inc. ADM Calibration Rev 28 -02-22-22 7855 East Redfield Road Scottsdale, Arizona 85260 (480) 991-6744 • Fax (480) 443-1267 • www.shortridge.com 1 of 2 02/22/2022 AIRDATA MULTIMETER CERTIFICATE OF CALIBRATION LOW VELOCITY CONFIRMATION (FPM) TEST METER TOLERANCE=± 3.0% ± 7 FPM Vel Eqv Trans Std: SIN: M02009 Vel Eqv Trans Std: SIN: M02903 Vel Eqv Trans Std: SIN: M10839 Vel Eqv Trans Std: SIN: M10840 Vel Eqv Trans Std: SIN: M10897 Vel Eqv Trans Std: SIN: M10901 Vel Eqv Trans Std: SIN: M13492 Vel Eqv Trans Std: SIN: M19325 Approx Set Point Standard Test Meter II 100 500 sos S/N: M 7,,Z5 76 Order#: L 3 0 I I S: .z Diff -t ADM-880C, ADM-870C and ADM-860C AirData Multi meters are read in AirFoil Mode. ADM-850L AirData Multi meters are read in Pitot Tube Mode. Equivalent Set Point 35.60 95.00 154.40 TEMPERATURE TEST -AIRDATA MULTIMETER(° F) TEST METER TOLERANCE = ± 0.2° F RTD Simulator: SIN 249 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 250 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 253 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 254 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 256 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 257 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 292 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 293 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 294 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 313 Set Point: @D 95° F 154.4° F RTD Simulator: SIN 314 Set Point: 35.6° F @£) 154.4° F RTD Simulator: SIN 315 Set Point: 35.6° F 95° F ~ RTD Simulator: SIN 316 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 317 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 318 Set Point: 35.6° F 95° F 154.4° F RTD Simulator Temperature Test Meter Diff NOTES:---------------------------------------- Procedure used: Procedure for Differential Pressure, Absolute Pressure and Temperature Calibration of AirData Multimeters SIP-CP01 Revision: 17 Dated: 12/10115. There were no additions to or deviations from the calibration procedure during this calibration process. This instrument has been calibrated using Calibration Standards which are traceable to NIST (National Institute of Standards and Technology). Test accuracy ratio is 4: 1 for pressures and temperature. Quality Assurance Program and calibration procedures meet the requirements for ANSI/NCSL 2540-1, ISO 17025, MIL-STD 45662A and manufacturer's specifications. Calibration accuracy is certified when meters are used with properly functioning accessories only. All Uncertainties are expressed in expanded terms (twice the calculated uncertainty). This report shall not be reproduced, except in full, without the written approval of Shortridge Instruments, Inc. Results relate only to the item calibrated. Limitations on use: See Shortridge Instruments, Inc. Instruction Manual for the use of AirData Multimeters Any calibration due date shown is specified by the customer. The enclosed ADM Calibration Standards for Pressure and Temperature form is an integral part of this calibration and must remain with this Certificate of Calibration. Calibration Technician(s): --13. J.._, Calibration Date: 0 I / '2-'t / 2o L :Z Calibration Approved by:__,,J;C);::........Je,~ ..... oxJo=;;......;..---------Title: Co.Q • ~. ADM Calibration Rev 28 • 02-22-22 Shortridge Instruments, Inc. 7855 East Redfield Road Scottsdale, Arizona 85260 (480) 991-6744 • Fax (480) 443-1267 • www.shortridge.com 2 of 2 02/22/2022 Shortridge Instruments, Inc. AirData Multimeter Calibration Equipment Order Number: Z. ~ 0 I I S Serial Number: M Z 7..5 7 6 Test Type: ~ As-Received Final ADM#02-R SIN: 41741/42451 ADM#04-R SIN: 41743142453 ADM#06-R 5/N: 41742/42452-1 ADM #08-R 5/N: 42186143328 ADM #10-R SIN: 42203/43352 ADM#12A-R 5/N: 45605/48491 ADM #14-R 5/N: 43412/45043-2 ADM#16-R SIN: 43413/45044 ADM #18-R 5/N: 44581/48845 Heise Model: PPM-2 Heise Model: PPM-2 Heise Model: PPM-2 Heise Model: PPM-2 Heise Model: PPM-2 Heise Model: PPM-2 Heise Model: PPM-2 Heise Model: PPM-2 Heise Model: PPM-2 ABSOLUTE PRESSURE STANDARDS Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 04/28/22 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 11/19/21 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 09/01/22 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/26/22 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03107122 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 08/01/22 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 09128/22 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 01/27122 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 10/26/21 ADM #20-R SIN: 44582/46847 Heise Model: PPM-2 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 07107/22 Resolution: 0.01 Resolution: 0.001 #02-R, 04-R, 06-R, 08-R, 10-R, 12A-R, 14-R, 16-R Rated Accuracy: 0.05% fs (0.0305 In Hg) Range: 0-30 psia #18-R, 20-R Rated Accuracy: 0.05% fs (0.0305 in Hg) Range: 0-60 In Hg DIF FERENTIAL PRESSURE STANDARDS ADM#01-L SIN: 41739142449 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 04128122 ADM #01-R SIN: 41739142446 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 04/29122 ADM #02-L SIN: 41741142454 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 04/28/22 ADM #03A-L SIN: 45570148481 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 11/24121 ADM #03A-R SIN: 45570/48460 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 11/24121 ADM#04-L SIN: 41743/42456 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 11123/21 ADM#05-L SIN: 417 40/42450 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 09101/22 ADM#05-R SIN: 41740142447 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 09101/22 ADM#06-L SIN: 41742/42455 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 09/01122 ADM #07-L SIN: 42185/42166 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/29/22 ADM #07-R SIN: 42185143326 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/29122 ADM#08-L SIN: 42188143329 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/28/22 ADM#09-L SIN: 42202/43351 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/07122 ADM#09-R SIN: 42202/43350 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03107/22 ADM #10-L SIN: 42203/43353 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/07122 ADM #11-L SIN: 43165/44551-1 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 08/04122 ADM #11-R SIN: 43165/44730 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 08/04/22 ADM #12A-L SIN: 45605/48490-1 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 08/03122 ADM #13-L 5/N: 43415/45041 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 10/11122 ADM#13-R SIN: 43415/45039 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 10111122 ADM#14-L SIN: 43412/45045 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 10/11/22 ADM #15-L 5/N: 43416/45042 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 02/07122 ADM #15-R SIN: 43416145040-1 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 02/07/22 ADM #16-L SIN: 43413145046 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 02/07122 ADM#17-L SIN: 44579146842 Heise Model: PPM-1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 10/29121 ADM #17-R SIN: 44579/46841 Heise Model: PPM-1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 10/29/21 ADM #18-L SIN: 44581/46846 Heise Model: PPM-1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 10129/21 ADM #19-L SIN: 44580146844 Heise Model: PPM-1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 07 /14122 ADM #19-R 5/N: 44580/46843 Heise Model: PPM-1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 07/14122 ADM #20-L SIN: 44582/46848 Heise Model: PPM-1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 07114/22 #01-L, 03A-L, 05-L, 07-L, 09-L, 11-L, 13-L, 15-L, 17-L, 19-L Rated Accuracy: > 0.07% fs (0.000175 In we) Range: 0.0-0.25 in we Res.: 0.00001 #01-R, 03A-R, 05-R, 07-R, 09-R, 11-R, 13-R, 15-R, 17-R, 19-R Rated Accuracy: > 0.06% fs ( 0.003 in we) Range: 0.0-5.0 in wc Res.: 0.0001 #02-L, 04-L, 06-L, 08-L, 10-L, 12A-L, 14-L, 16-l, 18-L, 20-L Rated Accuracy: > 0.06% fs (0.03 in we) Range: 0.0-50.0 in wc ADM Cal Stnds Rev 17 02-22-22 Shortridge Instruments, Inc. 7855 East Redfield Road Scottsdale, Arizona 85260 (480) 991-6744 • Fax (480) 443-1267 • www.shortridge.com 1 of 2 Res.: 0.001 Due Date· 04/2023 Due Date: 12/2022 Due Date: 09/2023 Due Date· 02/2023 Due Date: 0312023 Due Date: 06/2023 Due Date: 09/2023 Due Date: 02/2023 Due Date: 11/2022 Due Date: 07/2023 Uncertainty: < 0.0358 Uncertainty: < 0.0358 Due Date: 04/2023 Due Date: 04/2023 Due Date: 04/2023 Due Date: 12/2022 Due Date: 12/2022 Due Date: 12/2022 Due Date: 09/2023 Due Date: 09/2023 Due Date: 09/2023 Due Date: 02/2023 Due Date: 02/2023 Due Date: 02/2023 Due Date: 0312023 Due Date: 03/2023 Due Date: 03/2023 Due Date: 08/2023 Due Date: 08/2023 Due Date: 0812023 Due Date: 09/2023 Due Date: 09/2023 Due Date: 09/2023 Due Date: 0212023 Due Date: 02/2023 Due Date: 02/2023 Due Date: 1112022 Due Date: 11/2022 Due Date: 11/2022 Due Date: 0712023 Due Date: 0712023 Due Date: 07/2023 Uncertainty: < 0.00035 Uncertainty: < 0.00348 Uncertainty: < 0.0346 01/03/2023 Shortridge Instruments, Inc. AirData Multimeter Calibration Equipment Customer Order Number, Meter Serial Number, and Test Type are referenced on page 1 LOW VELOCITY EQUIVALENT CONFIRMATION STANDARDS Vel Eqv Transfer Standard SIN: M02009 Model ADM-870C Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 08116/22 Vel Eqv Transfer Standard SIN: M02903 Model ADM-870C Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 12/28122 Vel Eqv Transfer Standard SIN: M10839 Model ADM-870C Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 10126/22 Vel Eqv Transfer Standard SIN: M10840 Model ADM-870C Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 10/26122 Vel Eqv Transfer Standard SIN: M10897 Model ADM-870C Mfg'd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 01125122 Vel Eqv Transfer Standard SIN: M10901 Model ADM-870C Mfg'd & Calibrated by Shortridge Instruments, inc. Calibration Date: 12/29122 Vel Eqv Transfer Standard SIN: M13492 Model ADM-870C Mfg'd & Calibrated by Shortridge Instruments, inc. Calibration Date: 08116122 Vel Eqv Transfer Standard SIN: M19325 Model ADM-870C Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 06130122 Due Date: 0812023 Due Date: 12/2023 Due Date: 1012023 Due Date: 10/2023 Due Date: 0112023 Due Date: 12/2023 Due Date: 0812023 Due Date: 0612023 Rated Accuracy: Velocity :t 1.5 % :t 3.5 fpm Range: 100-5000 fpm Resolution: 0.1 Uncertainty: <5.00 fpm at 100 fpm; <7.50 fpm at 500 fpm TEMPERATURE STANDARDS RTD Simulator SIN: 249 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 250 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 253 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 254 Model RTD-1000I500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 256 Model RTD-1000I500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 257 Model RTD-1000I500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 292 Model RTD-1000I500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 293 Model RTD-1000I500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 294 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 313 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 314 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 315 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 316 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 317 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 318 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs Rated Accuracy: 0.025% of setting Range: 100.00 n to 11111.10 n Thermometer #1 SIN 8A089/Thermistor SIN A410660 Thermometer #2 SIN 8B 104/Thermistor SIN 871507 Thermometer #5 SIN B11780/Thermistor SIN B10505 Thermometer #6 SIN B11782/Thermistor SIN B10509 Thermometer #7 SIN B49938/Thermistor SIN B482202 Model 150415610 Model 150415610 Model 150415610 Model 15041561 0 Model 15041561 0 Mfgd by Hart Scientific Calibrated by Fluke Mfgd by Hart Scientific Calibrated by Fluke Mfgd by Hart Scientific Calibrated by Fluke Mfgd by Hart Scientific Calibrated by Fluke Mfgd and Calibrated by Fluke Calibration Date: 04102120 Due Date: 0312024 Calibration Date: 04102/20 Due Date: 03/2024 Calibration Date: 04102120 Due Date: 03/2024 Calibration Date: 05104120 Due Date: 04/2024 Calibration Date: 05104/20 Due Date: 0412024 Calibration Date: 05104120 Due Date: 04/2024 Calibration Date: 01103120 Due Date: 0112024 Calibration Date: 01103120 Due Date: 0112024 Calibration Date: 01103120 Due Date: 01/2024 Calibration Date: 03/25122 Due Date: 0312026 Calibration Date: 03125122 Due Date: 03/2026 Calibration Date: 03/25122 Due Date: 03/2026 Calibration Date: 06106122 Due Date: 0512026 Calibration Date: 05123122 Due Date: 05/2026 Calibration Date: 05123/22 Due Date: 05/2026 Resolution: 0.01 n Uncertainty. $ 32 ppm Calibration Date: 02/24122 Due Date: 02/2024 Calibration Date: 11/04/20 Due Date: 11 /2022 Calibration Date: 05116/22 Due Date: 05/2024 Calibration Date: 06109122 Due Date: 06/2024 Calibration Date: 10/13121 Due Date: 10/2023 Rated Accuracy(combined): 0.0324° F Range: 32° F to 176° F Resolution: 0.001° F Combined Uncertainty with Baths: $ 0.040° F Temp Transfer Standard S/N M00136 Temp Transfer Standard SIN M96100 Rated Accuracy: 0.03° F Model ADM-870 Model ADM-870 Mf9d & Calibrated by Shortridge Instruments. Inc. Mfgd & Calibrated by Shortridge Instruments, Inc. Range: 33• F to 158° F Resolution: 0.01° F Total combined Uncertainty for MultiTemp and TemProbe testing : $ 0.046° F Calibration Date: 10/26/22 Calibration Date: 03115122 Uncertainty.< 0.023° F Due Date: 10/2023 Due Date: 0312023 This form must remain with the Certificate of Calibration corresponding to the Customer Order Number and Meter Serial Number referenced on page 1. ADM Cal Stnds Rev 17 02-22-22 Shortridge Instruments, Inc. 7855 East Redfield Road Scottsdale, Arizona 85260 (480) 991-6744 • Fax (480) 443-1267 • www.shortridge.com 2 of 2 01/03/2023 TEMPROBES CALIBRATION TEST REPORT Customer ID: 0 \ ~ 5 0 3 Multimeter Serial Number: Customer:!:~ 1 JtJc. City:,2/JJJ D+~6o State: ca Order#: Test By: -~~....__,~,.______________ Date: 0 I /~I /2.Q l3 Calibration Due Date: _____ _ Rh: 2 1.-) % Ambient Temperature: 7 l. ° F Barometric Pressure Z. g , 1,/ 7in Hg TEMPERATURE TEST(° F) _ I.E.MPIWBE TOLERANCE=± 0.3° F TEMPROBE MODEL NUMBER: ltl!J'L Y z_ TEMPROBE ID#: fP-M l2576 Test(s) with Customer's Meter D Test(s) with In-house Temperature Calibration Standard ✓ All Within Specification Yes CiYNo D Temperature Standard Thermometer #1 SIN 8A089 I Thermistor SIN A410660 Temperature Standard Thermometer #2 SIN 88104 I Thermistor SIN 871507 Temperature Standard Thermometer #5 SIN 811780 I Thermistor SIN 810505 Temperature Standard Thermometer #6 SIN 811782 I Thermistor SIN 810509 Temperature Standard Thermometer #7 SIN 849938 I Thermistor SIN 8482202 Temperature Standard AirData Multimeter SIN M00136 Temperature Standard AirData Multimeter SIN M96100 Approx Set Point Uncertainty • F Thermometer/Thermistor • F 35 ° F 0.00324 35,o 95 ° F 0.00324 95,0 155 ° F 0.00324 l55,o Set Poin~ 95° F 155° F Set Point: 35° F 95° F 155° F Set Point: 35° F 95° F ~ Set Point: 35° F 95° F 155° F Set Point: 35° F ~ 155° F Set Point: 35° F 95° F 155° F Set Point~ TemProbe • F Offset• F 3Y.'1 -I ' q 't. er -I' I 5 5, I I / TEMPERATURE TEST{° Fl,.. TEMPROBE TOLERANCE=± 0.3° F TEMP ROBE MODEL NUMBER: n VT Y L/ h TEMPROBE ID#: IP:: M l Z-57 6 Test(s) with Customer's Meter D Test(s) with In-house Temperature Calibration Standard ~ All Within Specification Yes ut' No D Temperature Standard Thermometer #1 SIN 8A089 I Thermistor SIN A410660 Temperature Standard Thermometer #2 SIN 88104 I Thermistor SIN 871507 Temperature Standard Thermometer #5 SIN 811780 I Thermistor SIN 810505 Temperature Standard Thermometer #6 SIN 811782 I Thermistor SIN 810509 Temperature Standard Thermometer #7 SIN 849938 I Thermistor SIN 8482202 Temperature Standard AirData Multimeter SIN M001 36 Temperature Standard AirData Multimeter SIN M96100 Approx Set Point Uncertainty • F Thermometer/Thermistor • F 35 ° F 0.00324 ,CJ 95 ° F 0.00324 ,o 155 ° F 0.00324 IS Set Poin@ 95° F 155° F Set Point: 35° F 95° F 155° F Set Point: 35° F 95° F (@!> Set Point: 35° F 95° F 155° F Set Point: 35° F ~155° F Set Point: 35° F 95° F 155° F SetPoi~ TemProbe • F Offset • F ,0 Procedure used: Procedure for Calibration/Recalibration of MultiTemps and/or TemProbes SIP-CP14 Rev: 03 Dated: 07/31/14. There were no additions to or deviations from the calibration procedure during this calibration process. Calibration standards used by Shortridge Instruments, Inc. are traceable to NIST (National Institute of Standards and Technology). Calibration is performed in accordance with ANSI/NCSL 2540-1, ISO 17025, MIL-STD 45662A and manufacturer's specifications. Calibration accuracy is certified when meters are used with properly functioning accessories onlY.. This report shall not be reproduced, except in full, without the written approval of Shortridge Instruments, Inc. Results relate only to the item calibrated. Limitations on use: See Shortridge Instruments, Inc. Instruction Manual for the use of AirData Multimeters. The enclosed ADM or HOM Calibration Standards form(s) is/are an integral part of this calibration and must remain with this Certificate of Calibration. Any calibration due date shown is specified by the customer. Calibration Approved by: \ ). B oJo)o Title:Co.Q..~. Date: o ;q 0 -i /4 {)~ TemProbes Cal Rev 02 04/25/2022 Shortridge Instruments, Inc. 7855 East Redfield Road Scottsdale, Arizona 85260 (480) 991 -6744 • Fax (480) 443-1267 • www.shortridge.com 1 of 1 04/25/22 Shortridge Instruments, Inc. AirData Multimeter Calibration Equipment Order Number: -Z. 2 0 I I 5' Serial Number:Tf>-M Z2576 Test Type: @ As-Received Final AOM#02·R ADM#04-R ADM#06-R ADM #08-R ADM #10-R SIN: 41741/42451 SIN: 417 43/42453 SIN: 41742/42452-1 SIN: 42186143328 SIN: 42203143352 Heise Model: PPM-2 Heise Model: PPM-2 Heise Model: PPM-2 Heise Model: PPM-2 Heise Model: PPM-2 ABSOLUTE PRESSURE STANDARDS Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 04128122 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 11119121 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 09101122 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03126122 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03107122 ADM #12A-R SIN: 45605148491 Heise Model: PPM-2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 08101/22 ADM #14-R SIN: 43412/45043-2 Heise Model: PPM-2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 09128122 ADM #16-R SIN: 43413/45044 Heise Model: PPM-2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 01/27122 ADM #18-R SIN: 44581146845 Heise Model: PPM-2 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 10126/21 ADM #20-R SIN: 44582/46847 Heise Model: PPM-2 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 07107/22 #02-R, 04-R, 06-R, 08-R, 10-R, 12A-R, 14-R, 16-R Rated Accuracy: 0.05% fs (0.0305 in Hg) Range: 0-30 psia Resolution: 0.01 #18-R, 20-R Rated Accuracy: 0.05% fs (0.0305 in Hg) Range: 0-60 in Hg Resolution: 0.001 DIFFERENTIAL PRESSURE STANDARDS ADM #01-L SIN: 41739142449 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 04/28/22 ADM#01-R SIN: 41739142446 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 04/29/22 ADM#02-L SIN: 41741/42454 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 04/28/22 ADM#03A-L SIN: 45570/48461 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 11124/21 ADM #03A-R SIN: 45570148460 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 11/24121 ADM#04-L SIN: 41743142456 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 11 /23121 ADM#05-L SIN: 41740142450 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 09101 /22 ADM#05-R SIN: 41740/42447 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 09101122 ADM#06-L SIN: 41742/42455 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 09101/22 ADM #07-L SIN: 42185142186 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/29122 ADM #07-R SIN: 42185143326 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03129/22 ADM #08-L SIN: 42186143329 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/28/22 ADM #09-L SIN: 42202/43351 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/07/22 ADM#09-R SIN: 42202/43350 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/07/22 ADM #10-L SIN: 42203/43353 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/07/22 ADM #11-L SIN: 43165144551-1 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 08104/22 ADM #11-R SIN: 43165144730 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 08/04122 ADM #12A-L SIN: 45605148490-1 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 08103/22 ADM #13-L SIN: 43415/45041 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 10/11122 ADM #13-R SIN: 43415/45039 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 10111122 ADM#14-L SIN: 43412/45045 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 10/11/22 ADM#15-L SIN: 43416145042 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 02/07/22 ADM #15-R SIN: 43416145040-1 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 02/07/22 ADM #16-L SIN: 43413145046 Heise Model: PPM-1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 02/07 /22 ADM #17-L SIN: 44579146842 Heise Model: PPM-1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 10/29/21 ADM #17-R SIN: 44579/46841 Heise Model: PPM-1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 10/29/21 ADM #18-L SIN: 44581/46846 Heise Model: PPM-1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 10/29/21 ADM #19-L SIN: 44580146844 Heise Model: PPM-1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 07114/22 ADM#19-R SIN: 44580/46843 Heise Model: PPM-1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 07/14/22 ADM#20-L SIN: 44582/46848 Heise Model: PPM-1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 07114122 #01-L, 03A-L, 05-L, 07-l, 09-L, 11-L, 13-L, 15-L, 17-L, 19-L Rated Accuracy: > 0.07% fs (0.000175 in we) Range: 0.0-0.25 in we Res.: 0.00001 #01-R, 03A-R, 05-R, 07-R, 09-R, 11-R, 13-R, 15-R, 17-R, 19-R Rated Accuracy:> 0.06% fs ( 0.003 in we) Range: 0.0-5.0 in we Res.: 0.0001 #02-L. 04-L, 06-L, 08-L, 10-L, 12A-L, 14-L, 16-L, 1 8-L, 20-L Rated Accuracy: > 0.06% fs (0.03 in we) Range: 0.0-50.0 in we Res.: 0.001 Shortridge Instruments, Inc. 7855 East Redfield Road Scottsdale, Arizona 85260 (480) 991-6744 • Fax (480) 443-1267 • www.shortridge.com ADM Cal Stnds Rev 17 02-22-22 1 of 2 Due Date: 0412023 Due Date: 12/2022 Due Date: 09/2023 Due Date: 02/2023 Due Date: 03/2023 Due Date: 0812023 Due Date: 09/2023 Due Date: 02/2023 Due Date: 1112022 Due Date: 07/2023 Uncertainty: < 0.0358 Uncertainty: < 0.0358 Due Date: 04/2023 Due Date: 04/2023 Due Date: 04/2023 Due Date: 12/2022 Due Date: 12/2022 Due Date: 12/2022 Due Date: 09/2023 Due Date: 0912023 Due Date: 09/2023 Due Date: 02/2023 Due Date: 02/2023 Due Date: 02/2023 Due Date: 03/2023 Due Date: 03/2023 Due Date: 03/2023 Due Date: 08/2023 Due Date: 08/2023 Due Date: 08/2023 Due Date: 09/2023 Due Date: 09/2023 Due Date: 09/2023 Due Date: 02/2023 Due Date: 02/2023 Due Date: 02/2023 Due Date: 1112022 Due Date: 11/2022 Due Date: 11 /2022 Due Date: 0712023 Due Date: 0712023 Due Date: 07/2023 Uncertainty: < 0.00035 Uncertainty: < 0.00348 Uncertainty: < 0.0346 01/03/2023 Shortridge Instruments, Inc. AirData Multimeter Calibration Equipment Customer Order Number, Meter Serial Number, and Test Type are referenced on page 1 LOW VELOCITY EQUIVALENT CONFIRMATION STANDARDS Vel Eqv Transfer Standard SIN: M02009 Model ADM-870C Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 08116122 Vel Eqv Transfer Standard SIN: M02903 Model ADM-870C Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 12/28122 Vel Eqv Transfer Standard SIN: M10839 Model ADM-870C Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 10126/22 Vel Eqv Transfer Standard SIN: M10840 Model ADM-870C Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 10126122 Vel Eqv Transfer Standard SIN: M10897 Model ADM-870C Mfg'd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 01125122 Vel Eqv Transfer Standard SIN: M10901 Model ADM-870C Mfg'd & Calibrated by Shortridge Instruments, inc. Calibration Date: 12/29122 Vel Eqv Transfer Standard SIN: M13492 Model ADM-870C Mfg'd & Calibrated by Shortridge Instruments, inc. Calibration Date: 08116122 Vel Eqv Transfer Standard SIN: M19325 Model ADM-870C Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 06130122 Due Date: 0812023 Due Date: 12/2023 Due Date: 1012023 Due Date: 1012023 Due Date: 0112023 Due Date: 1212023 Due Date: 0812023 Due Date: 0612023 Rated Accuracy: Velocity± 1.5 % ± 3.5 fpm Range: 100-5000 fpm Resolution: 0.1 Uncertainty: <5.00 fpm at 100 fpm: <7.50 fpm at 500 fpm TEMPERATURE STANDARDS RTD Simulator SIN: 249 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 250 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 253 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 254 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 256 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 257 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 292 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 293 Model RTD-1000I500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 294 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 313 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 314 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 315 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 316 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 317 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs RTD Simulator SIN: 318 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs Rated Accuracy: 0.025% of setting Range: 100.00 Oto 11111.10 0 Thermometer #1 SIN 8A089/Thermistor SIN A410660 Thermometer #2 SIN 8B104/Thermistor SIN 871507 Thermometer #5 SIN B11780/Thermistor SIN B10505 Thermometer #6 SIN B11782/Thermistor SIN B10509 Thermometer #7 SIN B49938/Thermistor SIN B482202 Model 150415610 Model 150415610 Model 15041561 0 Model 15041581 O Model 15041561 0 Mfgd by Hart Scientific Calibrated by Fluke Mfgd by Hart Scientific Calibrated by Fluke Mfgd by Hart Scientific Calibrated by Fluke Mfgd by Hart Scientific Calibrated by Fluke Mfgd and Calibrated by Fluke Calibration Date: 04102/20 Due Date: 0312024 Calibration Date: 04102/20 Due Date: 0312024 Calibration Date: 04102/20 Due Date: 0312024 Calibration Date: 05104120 Due Date: 0412024 Calibration Date: 05104120 Due Date: 0412024 Calibration Date: 05104120 Due Date: 0412024 Calibration Date: 01/03120 Due Date: 0112024 Calibration Date: 01103120 Due Date: 0112024 Calibration Date: 01103120 Due Date: 0112024 Calibration Date: 03125122 Due Date: 0312026 Calibration Date: 03125122 Due Date: 0312026 Calibration Date: 03125122 Due Date: 0312026 Calibration Date: 06106122 Due Date: 0512026 Calibration Date: 05123122 Due Date: 0512026 Calibration Date: 05/23122 Due Date: 0512026 Resolution: 0.01 0 Uncertainty: s 32 ppm Calibration Date: 02/24122 Due Date: 02/2024 Calibration Date: 11104/20 Due Date: 1112022 Calibration Date: 05116/22 Due Date: 05/2024 Calibration Date: 0610912.2 Due Date: 06/2024 Calibration Date: 10113121 Due Date: 1012023 Rated Accuracy(combined): 0_0324• F Range: 32• F to 176° F Resolution: 0.001 • F Combined Uncertainty with Baths: s 0.040° F Temp Transfer Standard SIN M00136 Temp Transfer Standard SIN M96100 Rated Accuracy: 0.03° F Model ADM-870 Model ADM-870 Mfgd & Calibrated by Shortridge Instruments. Inc. Mfgd & Calibrated by Shortridge Instruments, Inc. Range: 33• F to 155• F Resolution: 0.01 • F Total combined Uncertainty for MultiTemp and TemProbe testing : s 0.046° F Calibration Date: 10126122 Calibration Date: 03115122 Uncertainty: < 0.023 • F Due Date: 10/2023 Due Date: 03/2023 This form must remain with the Certificate of Calibration corresponding to the Customer Order Number and Meter Serial Number referenced on page 1 . ADM Cal Stnds Rev 17 02-22-22 Shortridge Instruments, Inc. 7855 East Redfield Road Scottsdale, Arizona 85260 (480) 991 -67 44 • Fax (480) 443-1267 • www.shortridge.com 2 of 2 01/03/2023 AIRDATA MULTIMETER CERTIFICATE OF CALIBRATION -AIR FLOW Customer ID: 0 \ '35 0 _3 Customer: M BO , rtJ C, • City: S 8N Dif &-0 S/N: M 225 76 State: __ C~/>,~-- Model#: ADn-'8"6oc Order #: '-;>O I I S This instrument has been calibrated using Calibration Standards which are traceable to NIST (National Institute of Standards and Technology). Test accuracy ratio is 2:1 for air flow calibration. Quality Assurance Program and calibration procedures meet the requirements for ANSI/NCSL 2540-1, ISO 17025, MIL-STD 45662A and manufacturers specifications. Calibration accuracy is certified when meters are used by a properly trained technician using properly functioning accessories only. If this meter has been calibrated for air flow using Shortridge Instruments, Inc. In-house Calibration Standard FlowHood Assembly: S/N:IH1284 with Shortridge Instruments, Inc. In-House FlowHood Grid Assembly S/N:IH1284-A, these airflow readings may not be indicative of the readings obtained with a less well maintained Flowhood Assembly. This report shall not be reproduced, except in full, without the written approval of Shortridge Instruments, Inc. Results relate only to the item calibrated. Procedure used: Procedure for Air Flow Calibration of AirData Multi meters on a FlowHood SI P-CP15 Revision: 04 Dated: 07/31/14. There were no additions to or deviations from the calibration procedure during this calibration process. Any calibration due date shown is specified by the customer. Limitations on use: See Shortridge Instruments, Inc. Instruction Manuals for the use of AirData Multimeters and FlowMeters. AIR FLOW TEST (cfm) TEST METER TOLERANCE: ± 3.0% of reading ± 7 cfm Calibration Equipment: FlowHood Stand Calibration Transfer Standard AirData Multimeter Model ADM-870, Serial Number M99083 or M98543 and FlowHood Calibration Stand SIN 7401 calibrated as a system. Manufactured by Shortridge Instruments, Inc. System Calibration Date: 05124- 0512712021 . System Calibration Due Date: 0512023. FlowHood Stand Calibration Transfer Standard AirData Multimeter Model ADM-870, Serial Number M99420 and M96452 and FlowHood Calibration Stand SIN 7401 calibrated as a system. Manufactured by Shortridge Instruments, Inc. System Calibration Date: 04125-04/2812022. System Calibration Due Date: 0412024. Rated accuracy of system is± 1.5% of reading ± 3.5 cfm. Resolution: 0.1 cfm. Uncertainty of system is as stated at each Set Point. All specified uncertainties are expressed in expanded terms (twice the calculated uncertainty). All readings are compensated for the density effects of barometric pressure and temperature. AIR FLOW TEST CONDITIONS FlowHood Stand Calibration Transfer Standard AirData Multimeter used for air flow calibration: M96452 □ M98543 □ M99083 □ M99420 ~ Test performed using: Customer's: FlowHood Assembly 0' Shortridge Instruments, Inc.: In-House FlowHood Assembly □ Relative Humidity: _ __.-'2e:........:h'--__ % Ambient Temperature: 7 5 ° F Barometric Pressure: '2..8. '-i 2 in Hg Calibration Technician(s): ~<:::::::_ Calibration Date: 02/0 6/2,0 Z '3 ' Calibration Approved by: __,8)...._..:...., B.....,.o.)o,b~=:......_ ______ Title: CoQ 9-~. Date: D;}. / D "7 /°d-o ;L;, Approx Set Point Uncertainty Transfer Standard cfm Test Meter cfm Difference 100 <5.0 % /t>6 /OS' 2 500 < 1.5 % S-3/ S-s.59 ~ 1000 < 1.5 % 10415 101>! (;, 1500 < 1.25 % /5°>5 i q68 /3 2000 < 1.25 % ,Z c::>D c:::, -z_ol/4-'-I 'f Notes:-------------------------------------------- Shortridge Instruments, Inc. 7855 East Redfield Road Scottsdale, Arizona 85260 (480) 991-6744 • Fax (480) 443-1267 • www.shortridge.com Cal -850-860-870-880 Multimeter Air Flow -Rev13 -12-29-21 1 of 1 04/29/2022 GFFIGE USE ONLY I ~I Malling Address City Slate Zip Code I~ 2855 Gazelle Court Cartsbad CA 9201 0 Plan File# Project Contact Applicant E-mail Telephone# Wayne Sanders wsanders@lonisph.com 760-603-2562 \ The following questions represent the facility's activities, NOT the specific project description. t PART I: Fl p -MATERIALS DI s ONt OCCUPANGY -SSIFIO:ATION· ot utred ft>t tb iJtt! Wltfiln me Cil of I I I o : n icate by circling the ,tern, whether your business wtll use, process. or store any or the oUowmg hazardous mater als. I any o the items are circled. I I applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. (The project is an office tenant Improvement) r\ Occupancy Rating: A & B Facility's Square Footage (including proposed project): 69,200 s.f. 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives 2. Compressed Gases 6. Oxidizers 10. Cryogenics J.4. Other Health Hazards 3. Flammable/Combustible Liquids 7. Pyrophorfcs 11. Highly Tox,c or Toxic Materials \!;I None of These. 4. Flammable Solids 8. Unstable Reactives 12. Rad oacllves PART II: SAN DIEGO COUNTY DEPARTM MEN AL HEAL T : II the answer to any of the questions s yes, app ,cant must contact the aunty of an ego Hazardous Mater as 1v1sion, 55 n Diego, CA 92123. Call (858) 505-6700 prior lo the issuance of a building permit. FEES ARE REQUIRED Project Completion Dale: Expected Date of Occupancy: December. 2022 1. 2. 3. 4. 5. 6. 7. 8. YES NO (The project is an office tenant improvement) (fOf new construction or remodeling projects) D IE Is your business listed on the reverse side of this form? (check all that apply). D Ix) Will your business dispose of Hazardous Substances or Medical Waste in any amount? D 00 Will your business store or handle Hezardous Substances in quantit1es great~r thlltt ~I' equal lo 55 gallons. 500 pounds and/or 200 cubic feet? 0 00 Will your buSiness store or handle carcinogens/reproductive toxins in any quantity? D IX] WIN your business use an existing or install an underground storage tank? D Ix) Will your business store or handle Regulated Substances (CatARP)? D 00 Will your busi~s use or Install a Hazardous Waste Tank System (Title 22, Article 10)? 0 ~ Will your busine~e petroleum in tanks or containers at your facility with a total facility storage capacity equal to or realer than 1.320 atlons? California's Above round Petroleum Stora e Act . 0 CalARP Exempt I Date Initials d CalARP Required Date Initials 0 CalARP Complete I Date Initials PA R POLLut 6N (!<'.)lfffiOL D TR° CT APCD • Any YES' answer requires a stamp from APCD 10124 Old Grove Road, San Diego, A 1 . v 58) 6 -650). ['No stamp required if 01 Yes a!1Q 03 Yes and 04-06 No]. The following questions are Intended to identify the majority of air pollution issues at t planning stage. Projects may require additional measures not Identified by these questions. For comprehensive requirements oontact APCD. Residences are typically exempt, except -those with more than one building' on the property; single buildings \1/ilh more than four dwelling units; townhomes; condos; mixed-commerclal use; deliberate bums; residences forming part of a larger project. rExcludes garages & small outbuildings.) YES NO D 00 WiU any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition. ti 2 1_. Ix) D Will the project disturb 160 square feet or more of existing building materials? 3. IX) D (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been petfottttell by a Cei\mea Asbestos Consultant or Site Surveillance 1 r] Technician? h11 4. 0 IX) (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the proJect disturb any asbestos containing material? NotiflC8tion U,1 may be required 10 working days prior to commencing asbestos removal. ; ~I 5. 0 00 Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCO factsheel 1 I,. (www.sdaooo.org/jnfo/facls/peQDtts.pdfl for typical equipment requiring an APCD permit. J ~1 6. 0 1XJ {ANSWER ONLY IF QUESTION 5 IS YES) WIii the project or associated construction equipment be located within 1,000 feel of a school i I bounda ! ~1 BrieOy describe business activities· ; • Conference center and offices Brieny J~ribe proposed project: Conference center and offices true and correct. , 11 declare under penalty of perjury that lo the best of my know1edge and bef 1,, Wayne Sanders ::::_--,1-,µ~~~~~~=:.J.....::'-------I I Name or Owner or Authorized A ent Si u of 1 Dale !i. FOR OFFICAL US FIRE DEPARTMENT OCCUPANCY Ct.ASSIFICATION: ________________ 1 .....-__ 1 ___________ _ DATE· EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY Rl!LEASED FOR OCCUPANCY COUNTY-HMO' APCD COUNTY-HMO APCD COUNTY-HMO APCD ' . . 'A stamp ,n this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other perm1tt1ng requirements may still apply . HM-9171 (M/15) County or San Diego -DEH -Hazardous Materials Division