Loading...
HomeMy WebLinkAboutSDP 2018-0004; ROMERIA POINTE APARTMENTS; GEOTECHNICAL UPDATE REPORT; 2021-08-17THESE PLANS/DOCUMENTS HAVE BEENREVIEWED FOR COMPLIANCE WITH THEAPPLICABLE CALIFORNIA BUILDING STANDARDSCODES AS ADOPTED BY THE STATE OFCALIFORNIA AND AMENDED BY THEJURISDICTION. PLAN REVIEW ACCEPTANCE OFDOCUMENTS DOES NOT AUTHORIZECONSTRUCTION TO PROCEED IN VIOLATION OFANY FEDERAL, STATE, NOR LOCAL REGULATION.BY: _________________ DATE: ________________ True North Compliance Services, Inc. THIS SET OF THE PLANS AND SPECIFICATIONSMUST BE KEPT ON THE JOB SITE AT ALL TIMESAND IT IS UNLAWFUL TO MAKE ANY CHANGESOR ALTERATIONS WITHOUT PERMISSION FROMTHE CITY. OCCUPANCY OF STRUCTURE(S) ISNOT PERMITTED UNTIL FINAL APPROVAL ISGRANTED BY ALL APPLICABLE DEPARTMENTS. Scott Weisse 07/23/24 GEOTECHNICAL UPDATE ROMERIA POINTE APARTMENTS 7527 ROMERIA STREET CARLSBAD SAN-DI ~ 009 ASSESSOR' , ND -13-00 Cl 04 • BNR.JNVESTMl§bl'T AND DEVELOPM -----28000 VIA DEi: RIO ---- YORBA LINDA, CALIFORNIA 92887 W.O. 7297-A4-SC AUGUST 17, 2021 • Geotechnical • Geologic • Coastal • Environmental 5741 Palmer Way • Carlsbad, California 92010 • (760) 438-3155 • FAX (760) 931-0915 • www.geosoilsinc.com August 17, 2021 BNR Investment and Development, LLC 28000 Via Del Rio Yorba Linda, California 92887 Attention: Mr. Neal Desai W.O. 7297-A4-SC Subject: Geotechnical Update, Romeria Pointe Apartments, 7527 Romeria Street, Carlsbad, San Diego County, California 92009, Assessor's Parcel Numbers (APNs) 216-300-12-00 and -13-00, City of Carlsbad Project No.: SDP2018-0004 Dear Mr. Desai: In accordance with your request and authorization, GeoSoils, Inc. (GSI) is pleased to present this geotechnical update relative to the planned multi-family residential development at the subject site. The purpose of our study was to update the geotechnical aspects of the planned development to the currently recognized building codes (i.e., the 2019 California Building Code [California Building Standards Commission, 2019] and the American Society of Civil Engineers 7-16 [American Society of Civil Engineers, 2017] -see the Appendix). The scope of our services has included reviews of the referenced documents, listed in the Appendix, and the preparation of this summary report, which provides updated geotechnical recommendations for seismic shaking parameters, earthwork construction, and foundation design. Unless specifically superceded herein, the conclusions and recommendations presented in the referenced geotechnical reports (see the Appendix) remain valid and applicable, and should be appropriately implemented during the balance of project design and construction. UPDATED SEISMIC DESIGN PARAMETERS The following table summarizes the updated site-specific seismic design criteria obtained from the 2019 California Building Code (CBC), Chapter 16 Structural Design, Section 1613, Earthquake Loads (California Building Standards Commission [CBSC], 2019) and American Society of Civil Engineers (ASCE) 7-16 (ASCE, 2017). The computer program Seismic Design Maps, provided by the California Office of Statewide Health Planning and Development (OSHPD) and the Structural Engineers Association of California (SEAOC) was utilized to calculate the mapped seismic design parameters (https://seismicmaps.org). The short spectral response utilizes a period of 0.2 seconds. Based on a review of the existing subsurface data summarized in the project geotechnical reports (see the Appendix), it remains our conclusion that Site Class "D" conditions are applicable. I 2019 CBC SEISMIC DESIGN PARAMETERS I MAPPED VALUE PER SITE SPECIFIC PARAMETER OSHPD/SEAOC VALUE PER 2019 CBC or REFERENCE ASCE7-16 Risk Category(1l II II Table 1604.5 Site Class D D Section 1613.2.2/Chap. 20 ASCE 7-16 (p. 203-204) Spectral Response -(0.2 sec), s. 0.968 g 0.840g Section 1613.2.1 Figure 1613.2.1 (1) Spectral Response -(1 sec), S1 0.352 g 0.633 9 Section 1613.2.1 Figure 1613.2.1 (2) Site Coefficient, F. 1.2 1.164(2) Table 1613.2.3(1) Site Coefficient, Fv null -see Section 11 .48 2_5(3) Table 1613.2.3(2) ASCE 7-16 (Section 21 .3) Maximum Considered Earthquake Spectral 1.161 g 1.263 9(4) Section 1613.2.3 Response Acceleration (0.2 sec), SMS (Section 21.4) (Eqn 16-36) Maximum Considered Earthquake Spectral null -see Section 11 .48 1.026 9(5) Section 1613.2.3 Response Acceleration (1 sec),SM1 ASCE 7-16 (Section 21.4) (Eqn 16-37) 5% Damped Design Spectral Response 0.774g 0.8429(6) Section 1613.2.4 Acceleration (0.2 sec), Sos (Eqn 16-38) 5% Damped Design Spectral Response null -see Section 11 .48 0.6849(7) Section 1613.2.4 Acceleration (1 sec), S01 ASCE 7-16 (Section 21.4) (Eqn 16-39) PG~ -Probabilistic Vertical Ground Acceleration may be assumed as about 50% 0.507g 0.5289 ASCE 7-16 (Eqn 11 .8.1) of these values. Seismic Design Category null -see Section 11 .48 D(B) Section 1613.2.5/ASCE 7-16 ASCE 7-16 /Section 11.6) /o. 85: Table 11.6-1 or 11.6-2) 1. Risk Category to be confirmed by the Project Architect or Structural Engineer. 2. Per Table 11.4-1 of ASCE 7-16. 3. Per Section 21.3 of ASCE 7-16, if S1 ~ 0.2 then F v is taken as 2.5. 4. Per Section 21.4 of ASCE 7-16, SMS = (1.5)(Sos) = (1.5)(0.842 g) = 1.263 g. 5. Per Section 21.4 of ASCE 7-16, SM1 = (1 .5)(S01) = (1 .5)(0.684 g) = 1.026 g. 6. Per Section 21.4 of ASCE 7-16, Sos shall be taken as 90 percent of the maximum spectral acceleration (SJ obtained from the site-specific spectrum at any period within the range from 0.2 to 5 seconds, inclusive. 7. Per Section 21.4 of ASCE 7-16, S01 shall be taken as the maximum value of the product TS. obtained from the site-specific spectrum from the period within the range of 1 to 5 seconds, inclusive. 8. Per Table 11.6-1 of ASCE 7-16 Sn, ;, 0.2 = > 0.858 ;, 0.2. Thus the seismic desian cateaorv is "D". UPDATED SEISMIC SURCHARGE FOR RETAINING WALL DESIGN For building walls and site retaining walls with more than 6 feet of retained materials, as measured vertically from the bottom of the wall footing at the heel to daylight, or retaining walls that could present ingress/egress constraints to emergency equipment and personnel in the event of failure, GSI recommends that the walls be evaluated for seismic surcharge in general accordance with 2019 CBC requirements. The retaining walls in this category should maintain an overturning Factor-of-Safety (FOS) of approximately 1.25 when the seismic surcharge (increment), is applied. For restrained walls, the seismic surcharge should be applied as a uniform surcharge load from the bottom of the footing (excluding shear keys) to the top of the backfill at the heel of the wall footing. For cantilevered walls, the seismic increment should be applied as an inverted triangular pressure distribution from 0.6H above the bottom of the wall footing to the top of the wall. BNR Investment and Development, LLC 7527 Romeria Street, Carlsbad File:e:\wp21 \7200\7297a4.gur GeoSoils, Inc. W.O. 7297-A4-SC August 17, 2021 Page2 The seismic surcharge pressure (seismic increment) may be taken as 15H where "H" is the wall dimensions for restrained and cantilevered retaining walls previously noted in the preceding paragraph. For the evaluation of the seismic surcharge, the bearing pressure may exceed the static value by one-third, considering the transient nature of this surcharge. Please note this is for local wall stability only. The seismic lateral earth pressure (increment) for the proposed retaining walls be obtained from the following equation developed by the City of Los Angeles Department of Building and Safety ([LADBS], 2020), which is based on Seed and Whitman (1970). Where: Y EFP(seismic) Ysoi/ YEFP (seismic) = ¾khYsoil is the seismic increment expressed as equivalent fluid pressure (pounds per cubic foot [pcf]); is the seismic lateral earth pressure coefficient equivalent to one-half of two-thirds of PG~ (0.528 g x % x ½ = 0.176 g); is the total unit weight of the retained soils (115 pcf) Thus, for the proposed retaining walls: Y EFP (seismic) = ¾ x ½ x % x 0.528 x 115 pcf = 15.2 pcf (use 15 pcf [15H]) UPDATED PRELIMINARY EARTHWORK CONSTRUCTION RECOMMENDATIONS In addition to the preliminary recommendations contained in the referenced geotechnical reports (see the Appendix), all earthwork should conform to the guidelines presented in Appendix Chapter J of the 2019 California Building Code, and the requirements of the City of Carlsbad. Grading should be performed under the observation and testing of GSI. UPDATED PRELIMINARY RECOMMENDATIONS -FOUNDATIONS The design and construction of the building foundations should conform to the preliminary recommendations provided in the referenced geotechnical reports and the guidelines presented in the 2019 California Building Code and American Society of Civil Engineers 7-16. BNR Investment and Development, LLC 7527 Romeria Street, Carlsbad File:e:\wp21 \7200\7297a4.gur GeoSoils, Inc. W.O. 7297-A4-SC August 17, 2021 Page3 LIMITATIONS The materials encountered on the project site and utilized for our analysis are believed representative of the area; however, soil and bedrock materials vary in character between excavations and natural outcrops or conditions exposed during mass grading. Site conditions may vary due to seasonal changes or other factors. Inasmuch as our study is based upon our review and engineering analyses and laboratory data, the conclusions and recommendations are professional opinions. These opinions have been derived in accordance with current standards of practice, and no warranty, either express or implied, is given. Standards of practice are subject to change with time. GSI assumes no responsibility or liability for work or testing performed by others, or their inaction; or work performed when GSI is not requested to be onsite, to evaluate if our recommendations have been properly implemented. Use of this report constitutes an agreement and consent by the user to all the limitations outlined above, notwithstanding any other agreements that may be in place. In addition, this report may be subject to review by the controlling authorities. Thus, this report brings to completion our scope of services for this portion of the project. BNR Investment and Development, LLC 7527 Romeria Street, Carlsbad File:e:\wp21 \7200\7297a4.gur GeoSoils, Inc. W.O. 7297-A4-SC August 17, 2021 Page4 The opportunity to be of service is sincerely appreciated. If you should have any questions, please do not hesitate to contact our office. Respectfully submitted, GeoSoils, Inc. ~~-1:::!- Engineering Geologist, !B1!e, - Staff Geologist RBB/JPF /DWS/sh Attachments: Distribution: Appendix -References (1) Addressee (via email) ~~ Civil Engineer, ACE 47857 (1) Streamline Development Group BNR Investment and Development, LLC 7527 Romeria Street, Carlsbad File:e:\wp21 \7200\7297a4.gur GeoSoils, Inc. W.O. 7297-A4-SC August 17, 2021 Page5 APPENDIX REFERENCES American Society of Civil Engineers, 2017, minimum design loads and associated criteria for buildings and other structures, provisions, ASCE Standard ASCE/SEI 7-16. California Building Standards Commission, 2019, California Building Code, California Code of Regulations, Title 24, Part 2, Volumes 1 and 2, based on the 2018 International Building Code. City of Los Angeles Department of Building and Safety, 2020, Information bulletin/ public - building code, reference no.: LABC 1610.1, 1807.2, document no.: P/BC 2020-083, dated January 1 . GeoSoils, Inc., 2019, Geotechnical response to issues raised at the June 11, 2019 City of Carlsbad City Council meeting pertaining to the geotechnical conditions at the Romeria Pointe Apartments project site and near vicinity, 7527 Romeria Street, Carlsbad, San Diego County, California 92009, Assessor's Parcel Numbers (APNs) 216-300-12 &-13, City of Carlsbad project no.: SDP2018-0004, W.O. 7297-A3-SC, dated November 30. __ , 2018a, Geotechnical response to City of Carlsbad review comments dated October 19, 2018, Romeria Pointe Apartments, 7527 Romeria Street, Carlsbad, San Diego County, California 92009, Assessor's Parcel Numbers (APNs) 216-300-12 &-13, City of Carlsbad Project No.: SDP2018-0004, W.O. 7297-A2-SC, dated December 6. __ , 2018b, Geotechnical review of title sheet and preliminary grading plans for: Romeria Pointe, 7527 Romeria Street, Carlsbad, San Diego County, California 92009, Assessor's Parcel Numbers (APNs) 216-300-12 & -13, W.O. 7297-A1-SC, dated September 12. __ , 2017, Geotechnical update evaluation, Romeria Pointe, multi-family residential development, Assessor's Parcel Numbers (APNs) 216-300-12 & -13, Carlsbad, San Diego County, California, W.O. 7297-A-SC, dated November 21. __ , 2007a, Final geotechnical review offoundation (drilled pier and post-tensioned slab) plans, notes, and details, Romeria Pointe Townhomes, Carlsbad, San Diego County, California, W.O. 4460-A6-SC, dated November 14. __ , 2007b, Geotechnical review of structural plans, Romeria Pointe Townhomes, Carlsbad, San Diego County, California, W.O. 4460-A4-SC, dated February 22. __ , 2006a, Memorandum: General discussion of recent cone penetration tests, Building A, Romeria Point, Carlsbad, California, W.O. 4460-A3-SC, dated October 13. GeoSoils, Inc. __ , 2006b, Revised geotechnical review of grading, post-tension foundation, and structural plans, Romeria Pointe Townhomes, Carlsbad, San Diego County, California, W.O. 4460-A3-SC, dated July 26. __ , 2006c, Geotechnical review of grading, post-tension foundation, and structural plans, Romeria Pointe Townhomes, Carlsbad, San Diego County, California, W.O. 4460-A3-SC, dated July 21. __ , 2005, Geotechnical review of post-tension foundation and structural plans, Romeria Pointe Town homes, Carlsbad, San Diego County, California, W.O. 4460-A 1-SC, dated March 8. __ , 2004, Preliminary geotechnical evaluation, Romeria Pointe, APNs 216-300-12 and -13, Carlsbad, San Diego County, California, W.O. 4460-A-SC, dated September 27. Seed, H. B. and Whitman, R. V., 1970, Design of earth retaining structures for dynamic loads, ASCE Specialty Conference, Lateral Stresses in the Ground and Design of Earth Retaining Structures, pp. 103-147. BNR Investment and Development, LLC . File:e:\wp12\7200\7297a4.gur Ge0S01ls, Inc. Appendix Page2