Loading...
HomeMy WebLinkAboutPD 2023-0008; 3229 HIGHLAND; DRAINAGE STUDY FOR 3229 HIGHLAND DRIVE; 2024-04-01DRAINAGE STUDY FOR PD 2023-0008 / GR 2023-0012 Proposed Single Story Residence, Accessory Dwelling Unit and Associated Site Improvements 3229 Highland Drive DWG. 541-9A Prepared for: John Collins and Jeannine Woo February 2023 Updated August 2023 Updated December 2023 Updated March 2024 Prepared by: __________________________ John L. Majocha RCE 81240 Residential Remodel and Associated Site Improvements – 3229 Highland Drive 2 METHODOLOGY AND PROCEDURE 1) The project is classified as a Standard Project per the E-34 Storm Water Standards Questionnaire. Per the requirements in the Carlsbad BMP Design Manual (Updated January 2, 2024), Standard Projects are only required to meet Source Control and Site Design Requirements. The proposed project has been designed to comply with Source Control and Site Design Requirements. 2) Proposed drainage Area B exceeds the above criteria utilizing stone area under the proposed underdrain to capture and infiltrate its associated Design Capture Volume generated by the 85th percentile rainfall. 3) The 85th percentile rainfall value for the site is 0.59 inches per Figure B.1-1 of the Carlsbad BMP Design Manual. 4) Design Capture Volume was determined using methodology presented in Appendix B.1 of the City of Carlsbad BMP Design Manual. Design Capture Volume calculations are provided in Appendix D 5) The proposed permeable pavers in proposed Area B have been sized to treat the 85th percentile rainfall volume due to the development of the portion of the site located in proposed Area B. The paver section volume calculations for pavers located in proposed Area Bare are included in Appendix E of this report. 6) The proposed permeable paver base section has been designed to have a drawdown time of less than 36 hours per the requirements indicated in Section B.4.1 of the Carlsbad BMP Design Manual. The design infiltration rate was determined as indicated in the Infiltration Testing Report for the Subject Property Located at 3229 Highland Drive, Carlsbad, CA 92008 dated July 27, 2023. The safety factor utilized in the infiltration testing report was determined using information in Tables D.2-3 and D.2-4 in the Carlsbad BMP Design Manual. The infiltration testing report and drawdown calculations are included in Appendix F of this report. 7) The on-site soils are characterized as hydrologic soil group of “B” per USDA National Resources Conservation Service (NRCS) Web Soil Survey information. Site NRCS soil mapping is included in Appendix B. 8) The runoff coefficient “C” was selected based on estimated percent imperviousness of each sub area and Table 3-1 of the San Diego County Hydrology Manual. Runoff coefficient calculations are provided in Appendix C. 9) Runoff intensities were developed using methodology from Section 3.1.3 of the San Diego County Hydrology Manual. 6-hour point precipitation estimates were taken from recent NOAA precipitation data included in Appendix C. 10) The site storm drain infrastructure has been designed using 10-year flows. Pipe calculations are included in Appendix G. Residential Remodel and Associated Site Improvements – 3229 Highland Drive 3 11) The velocity of the swale along the eastern property line was calculated using the 100-year flow. Swale calculations are included in Appendix H. These calculations support the drainage improvements associated with the proposed single-family residence, accessory dwelling unit, and associated site improvements to the residence located at 3229 Highland Drive. The proposed site drainage will maintain existing drainage patterns. Area A will include a portion of the roof areas of the proposed accessory dwelling unit and proposed single family residence, the proposed gravel pavement driveway, concrete driveways, and landscaped areas along the southern and southwestern portions of the site. Runoff from the proposed improvements in Area A will be treated using Source Control and Site Design Measures . Runoff from larger storm events will discharge to the Pine Avenue right-of-way similar to existing conditions. Area B includes the remainder of the accessory dwelling unit roof area, a portion of the single-family residence roof area, the proposed pool and associated patio, and landscape area north of the single-family residence. 85th percentile runoff generated from the proposed improvements will infiltrate into the proposed permeable paver patio. Runoff from larger storm events and the remainder of Area B will drain to the Pine Avenue right-of-way similar to existing conditions. Area C includes the eastern portion of the single-family residence roof, the concrete porch and paver walkway east of the single-family residence, and the concrete stairs at the retaining wall along the eastern property line. Runoff from the proposed improvements in Area C will be treated using Source Control and Site Design Measures. Runoff from larger storm events and the remainder of Area C will drain to the Pine Avenue right-of-way similar to existing conditions. Site impervious area is increased by approximately 279 SF. However, this impervious area increase did not increase the composite C-value of the project site. As a result, the site overall site runoff does not increase under proposed conditions as depicted on the tables below and on the drainage area maps depicting the existing and proposed on-site drainage areas included in Appendix A. Existing Conditions Proposed Conditions Area = 0.59 Acres Area = 0.59 Acres Q100 = 1.97 cfs Q100 = 1.97 cfs Residential Remodel and Associated Site Improvements – 3229 Highland Drive 4 APPENDIX A DRAINAGE MAP NORTH ~ I Gx---- T Gx --+- c; o; 'v I I c; "' 7J <] I m Cl .J~ X -cl ll_ AREA A EXISTING DESIGN FL □'w'S TOTAL TOTAL C 100-YR 100-YR AREA AREA TC CMIN) RUNOFF INTENSITY Ccfs) (sf) CACRES) COEFFICIENT CIN/HR) 25,730 0,59 5,0 0,46 7.25 1.97 I I ~ ( ,3 ~, ,,c,l \U( i -.,L---;r+'--,,--------,.~,x ------'---~;,.e--,,.+(---r:'--, '+JU"",J"--U "--(-+-se-,,-----s L'(_::F_' _s,-_1~,,,h,<Jl-----,5¼,,-t+-l+--""?T-'" ~) l.1 PINEf VENUE ( ( ( ~l Ul+(-----1(__ ( I I I \ I I " I ( =, ~ - \ ~ ( I I Cl X I _ l ,lll ,( ,( ASSUMPTIONS 1. TIME OF CONCENTRATION FOR ALL EXISTING DRAINAGE AREAS ARE ASSUMED TO BE 5 MINUTES DUE TO THEIR SMALL SIZE. 2. COMPOSITE C-VALUE CALCULATED USING C-VALUES OBTAINED FROM TABLE .3-1 OF THE 200.3 SAN DIEGO COUNTY HYDROLOGY MANUAL. 05-051-03-0 -C C u \ ) -, 7 I I I -----}- I J fi I D:\DRA\NING FILES\TllLE SHEETS\GRADING TITLE SHEET.DWG REVISED:02/15/17 J ( \ \ ·,., ~ ' " " " ' ' \ \ I I 11r I I ( 11 ; ~ I ~ /I l'I'' \ I II I I ,1,, I W X \ e-, "" _,,/ -- X V) V) X ,_ ~--::+;-+:__-}liq_ • i~ c~ \ ) ~ \ \Cai m D \ \ ' m " \ X " I X X 'JC, X Cl I \ ' ' ,J c,• ,j'i T.co \ o :Uc, ',·ie:--,, c. v/x------1---lwx---+---wx-------,-~ vi ,.c_ /I._., /, '~'W\~~,. L•l·-" fl I I 1.:J ,_ (_') ~ .3. INTENSITIES WERE DETERMINED USING [l=7.44*P6*DA{-.645}} PER SECTION .3.1 . .3 OF THE SAN DIEGO COUNTY HYDROLOGY MANUAL. 4. INTENSITY FOR 100-YEAR EVENT IS BASED ON 100-YR 6-HR PRECIPITATION OF 2.75-/NCHES -EXISTING 1=7.25 in/hr. 5. EXISTING INTENSITIES ARE IND/CA TED IN THE TABLE ABOVE. \ \ I I I 7 I I I I ! I I j I I O ) / I ( I I ( m _,,. I ( I \ \ ( m '-" \ I I I I I fr I f -- / I 1 I + I j I I I 11 I ) ) \ -m m I I \ I I - = I I / I I I I -, ,, ,~c~?'r:J s'i c, ,,,, / ',< 1)A1,, -,, nv,1c 7J:'5]-'7 ,, I I I I 1 I 7J 7J ( I ,11, ,--------t-------;, 'w x ----+,;;---w x -+-----+1~-+-+--w x/ I / c, ' /, /:, -,'-·I ___ ., , r /fY j _ '_{ I ) I Cl X ,( X ,( X Cl X Cl X Cl X Cl X Cl X Cl X ,-/ I I X V) '~ i_; '~ u - '~-VJ X wx ( J u Q-_ ~LJ I)_ Q- 1.Lj 0 ~ ~ I ,-=-,·; I ::-,•, f"1 ,( ,: -- x X X ,Cc_ ,c X :f X ,( ,c, ,: X ~~'.'. X ,( ,( X X ' I I I ____I r I I I I I I ,( ,( I X X I I I I I l I I \ I \ ~ I -l "' I I I I ,c \ ,c ; X X I I I \J ' ' ' ' ! ' ' ,c ' ,c ' X X ' I I ' O' 10 20 SCALE, I' = 10' "AS BUILT" RCE __ EXP, __ _ DATE REVIE'w'ED BY, INSPECTOR DA TE I SH~ET I CITY OF CARLSBAD I SH~ETS I t-----+----+---------------+--1---+----+----1 ENGINEERING DEPARTMENT l----+---+---------------+--1---+----+----I 3229 HIGHLAND DRIVE 1----+---+---------------+--1---+----+----1 GR 2023-0012 EXISTING DRAINAGE AREAS APPROVED:JASON S. GELDERT ENGINEERING MANAGER RCE 63912 EXP. 9/30/24 DATE l---cc-c=-+ccc=,..+<...._ ___________ -+--1----t-----+----I DWN BY: JLM DATE INITIAL ,__DA_TE~_INl_llA_L -+-D_ATE~_IN_l1l_Al_, CHKD BY: JLM ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWD BY: PROJECT NO. PD 2023-0008 DRAWING NO. 541-9A NORTH Gx--Gx~---- 1-ss A~----,\-- ,,,, ill\=-\JI D5-051-03-00 ., .. D:\DRA\NING FILES\TllLE SHEETS\GRADING TITLE SHEET.DWG REVISED:02/15/17 ' ' I ' I I _, - APN: 205-051-02-00 -------~ -----·; I I I I ' ' ' ' I C) C\J X : ,( X I ;J c, I I >< I I I I I I I I I I C) X C:', I / ':·) / Lt-) •.-._ / ;' C-2 C1 X C) X C) X C) X C1 X I X ' ' L ' u' +I? U_v? X " I l ) () I 0 ,( X l,l ' c:r_ X ,( X C, ,c X C_, X ,( X ,( X I I -------1 r-c c I X X X X I I I I I I I ;1 ! ! I I I ' I I I I z 1 X I I, : I I " I I I I I I I I I I I I I I I I I I I I I I I AREA A B C ASSUMPTIONS PROPOSED DESIGN FL □~S TOTAL AREA Csf) 9,675 9,478 6,577 TOTAL AREA CACRES) 0,22 0,22 TC CMIN) 5,0 5,0 5,0 C RUNOFF COEFFICIENT 0,44 0,52 0,41 100-YR INTENSITY CIN/HR) 7,25 7,25 7,25 TOTAL 100-YR Ccfs) 0,70 0,83 0,44 1.97 1. TIME OF CONCENTRATION FOR ALL PROPOSED DRAINAGE AREAS ARE ASSUMED TO BE 5 MINUTES OUE TO THEIR SMALL SIZE. 2. COMPOSITE C-VALUE CALCULATED USING C-VALUES OBTAINED FROM TABLE 3-1 OF THE SAN DIEGO COUNTY HYDROLOGY MANUAL. 3. INTENSmES WERE DETERMINED USING [l=7.44'P6•D-(-.645}] PER SECTION 3.1.3 OF THE SAN DIEGO COUNTY HYDROLOGY MANUAL. 4. INTENSITY FOR 100-YEAR EVENT IS BASED ON 100-YR 6-HR PRECIPITATION OF 2.75-INCHES -PROPOSED 1=7.25 in/hr. 5. PROPOSED INTENSITIES ARE INDICATED IN THE PROPOSED TABLES ABOVE. O' 10 2,0 -- ' SCALE, I' = 10' !?1i u, II z z X X I I I I I I I I "AS BUILT" I I I I I RCE __ _ EXP, ___ _ DATE REVIE'w'ED BY, INSPECTOR DA TE t---+-----+-------------+---+----+----+-----t I SH~ET I CITY OF CARLSBAD I SH~ETS I :==::::::'....::::::=:::EN:::G::::I=NE:::E::::R:::IN=G::::::::D:::E=PA:::R=T=M:::E=NT==:::::'....'.==::::::: 3229 HIGHLAND DRIVE 1---+-----11------------------+---+---t---t----1 GR 2023-0012 PROPOSED DRAINAGE AREAS DAlE INITIAL DAlE INlllAL DAlE INlllAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL APPROVED:JASON S. GELDERT ENGINEERING MANAGER DWN BY: JLM CHKD BY: JLM RVWD BY: RCE 63912 EXP. 9/30/24 DAlE PROJECT NO. PD 2023-0008 DRAWING NO. 541-9A Residential Remodel and Associated Site Improvements – 3229 Highland Drive 5 APPENDIX B NRCS SOIL SURVEY INFORMATION Soil Map—San Diego County Area, California(3229 Highland Drive) Natural Resources Conservation Service Web Soil SurveyNational Cooperative Soil Survey 2/20/2023Page 1 of 3 36 6 9 4 1 0 36 6 9 4 2 0 36 6 9 4 3 0 36 6 9 4 4 0 36 6 9 4 5 0 36 6 9 4 6 0 36 6 9 4 7 0 36 6 9 4 8 0 36 6 9 4 1 0 36 6 9 4 2 0 36 6 9 4 3 0 36 6 9 4 4 0 36 6 9 4 5 0 36 6 9 4 6 0 36 6 9 4 7 0 36 6 9 4 8 0 468600 468610 468620 468630 468640 468650 468660 468670 468680 468690 468700 468600 468610 468620 468630 468640 468650 468660 468670 468680 468690 468700 33° 9' 49'' N 11 7 ° 2 0 ' 1 2 ' ' W 33° 9' 49'' N 11 7 ° 2 0 ' 8 ' ' W 33° 9' 46'' N 11 7 ° 2 0 ' 1 2 ' ' W 33° 9' 46'' N 11 7 ° 2 0 ' 8 ' ' W N Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 11N WGS84 0 25 50 100 150Feet 0 5 10 20 30Meters Map Scale: 1:537 if printed on A landscape (11" x 8.5") sheet. Soil Map may not be valid at this scale. USDA = MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Map Unit Polygons Soil Map Unit Lines Soil Map Unit Points Special Point Features Blowout Borrow Pit Clay Spot Closed Depression Gravel Pit Gravelly Spot Landfill Lava Flow Marsh or swamp Mine or Quarry Miscellaneous Water Perennial Water Rock Outcrop Saline Spot Sandy Spot Severely Eroded Spot Sinkhole Slide or Slip Sodic Spot Spoil Area Stony Spot Very Stony Spot Wet Spot Other Special Line Features Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation ServiceWeb Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: San Diego County Area, CaliforniaSurvey Area Data: Version 18, Sep 14, 2022 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Mar 14, 2022—Mar 17, 2022 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Soil Map—San Diego County Area, California(3229 Highland Drive) Natural Resources Conservation Service Web Soil SurveyNational Cooperative Soil Survey 2/20/2023Page 2 of 3 § □ (I D (b 'C1 {j □ .... ~ 181 ,,,....., • +-H ◊ ~ X ~ . .. ~ 0 ~ A. • ~ 0 0 V + .... . . 0 J, %f USDA = Map Unit Legend Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI MlC Marina loamy coarse sand, 2 to 9 percent slopes 0.5 100.0% Totals for Area of Interest 0.5 100.0% Soil Map—San Diego County Area, California 3229 Highland Drive Natural Resources Conservation Service Web Soil SurveyNational Cooperative Soil Survey 2/20/2023Page 3 of 3USDA = San Diego County Area, California MlC—Marina loamy coarse sand, 2 to 9 percent slopes Map Unit Setting National map unit symbol: hbdz Elevation: 0 to 430 feet Mean annual precipitation: 9 to 12 inches Mean annual air temperature: 57 to 61 degrees F Frost-free period: 330 to 350 days Farmland classification: Prime farmland if irrigated Map Unit Composition Marina and similar soils:85 percent Minor components:15 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Marina Setting Landform:Ridges Down-slope shape:Linear Across-slope shape:Linear Parent material:Eolian sands derived from mixed sources Typical profile H1 - 0 to 10 inches: loamy coarse sand H2 - 10 to 57 inches: loamy sand H3 - 57 to 60 inches: sand Properties and qualities Slope:2 to 9 percent Depth to restrictive feature:More than 80 inches Drainage class:Somewhat excessively drained Runoff class: Medium Capacity of the most limiting layer to transmit water (Ksat):Moderately high to high (0.57 to 1.98 in/hr) Depth to water table:More than 80 inches Frequency of flooding:None Frequency of ponding:None Maximum salinity:Nonsaline to very slightly saline (0.0 to 2.0 mmhos/cm) Available water supply, 0 to 60 inches: Low (about 4.7 inches) Interpretive groups Land capability classification (irrigated): 3s Land capability classification (nonirrigated): 4e Hydrologic Soil Group: B Ecological site: F019XG915CA - Sandy Hills <30"ppt Hydric soil rating: No Map Unit Description: Marina loamy coarse sand, 2 to 9 percent slopes---San Diego County Area, California 3229 Highland Drive Natural Resources Conservation Service Web Soil SurveyNational Cooperative Soil Survey 2/20/2023Page 1 of 2~ Minor Components Carlsbad Percent of map unit:5 percent Hydric soil rating: No Corralitos Percent of map unit:5 percent Hydric soil rating: No Chesterton Percent of map unit:5 percent Hydric soil rating: No Data Source Information Soil Survey Area: San Diego County Area, California Survey Area Data: Version 18, Sep 14, 2022 Map Unit Description: Marina loamy coarse sand, 2 to 9 percent slopes---San Diego County Area, California 3229 Highland Drive Natural Resources Conservation Service Web Soil SurveyNational Cooperative Soil Survey 2/20/2023Page 2 of 2~ Hydrologic Soil Group—San Diego County Area, California(3229 Highland Drive) Natural Resources Conservation Service Web Soil SurveyNational Cooperative Soil Survey 2/20/2023Page 1 of 4 36 6 9 4 1 0 36 6 9 4 2 0 36 6 9 4 3 0 36 6 9 4 4 0 36 6 9 4 5 0 36 6 9 4 6 0 36 6 9 4 7 0 36 6 9 4 8 0 36 6 9 4 1 0 36 6 9 4 2 0 36 6 9 4 3 0 36 6 9 4 4 0 36 6 9 4 5 0 36 6 9 4 6 0 36 6 9 4 7 0 36 6 9 4 8 0 468600 468610 468620 468630 468640 468650 468660 468670 468680 468690 468700 468600 468610 468620 468630 468640 468650 468660 468670 468680 468690 468700 33° 9' 49'' N 11 7 ° 2 0 ' 1 2 ' ' W 33° 9' 49'' N 11 7 ° 2 0 ' 8 ' ' W 33° 9' 46'' N 11 7 ° 2 0 ' 1 2 ' ' W 33° 9' 46'' N 11 7 ° 2 0 ' 8 ' ' W N Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 11N WGS84 0 25 50 100 150Feet 0 5 10 20 30Meters Map Scale: 1:537 if printed on A landscape (11" x 8.5") sheet. Soil Map may not be valid at this scale. USDA = MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Rating Polygons A A/D B B/D C C/D D Not rated or not available Soil Rating Lines A A/D B B/D C C/D D Not rated or not available Soil Rating Points A A/D B B/D C C/D D Not rated or not available Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation ServiceWeb Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: San Diego County Area, CaliforniaSurvey Area Data: Version 18, Sep 14, 2022 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Mar 14, 2022—Mar 17, 2022 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Hydrologic Soil Group—San Diego County Area, California(3229 Highland Drive) Natural Resources Conservation Service Web Soil SurveyNational Cooperative Soil Survey 2/20/2023Page 2 of 4USDA = □ D D D D D D D D ,,..,,,. ,,..,,,. □ ■ ■ □ □ ,,..._., t-+-t ~ tllWI ,..,,. ~ • Residential Remodel and Associated Site Improvements – 3229 Highland Drive 6 APPENDIX C RUNOFF COEFFICIENT CALCULATIONS & NOAA PRECIPITATION DATA 17,454 SF 8,276 SF 25,730 SF 3229 HIGHLAND EXISTING C‐VALUE CALCULATIONS  15‐Feb‐2023 EXISTING C‐VALUES Pervious Area C‐Value (Cp)= 0.25 Per Table 3‐1 of the 2003 San Diego County Hydrology  Manual , LDR, Soil Type B Weighted Runoff Coefficient Equation in Section 3.1.2  of the 2003 San Diego County Hydrology Manual                 (C=0.90*(% Impervious)+Cp*(1‐% Impervious) AREA A Pervious Area =  Impervious Area =  Total Area =  Weighted C‐Value = 0.46 7,603 SF 2,796 SF 10,399 SF 5,470 SF 4,008 SF 9,478 SF 4,102 SF 1,751 SF 5,853 SF 3229 HIGHLAND PROPOSED C-VALUE CALCULATIONS 1-Dec-2023 PROPOSED C-VALUES AREA A Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B Impervious Area = Pervious Area = Impervious Area = Total Area = Weighted C-Value = AREA B Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B Pervious Area = 0.42 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) Total Area = Total Area = Weighted C-Value = 0.52 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA C Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B Pervious Area = Impervious Area = Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) Weighted C-Value = 0.44 2.75 inches 5.00 minDuration (D) = Rainfall Intensity (I) = 7.25 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual 3229 HIGHLAND DRIVE Existing Intensity Calculations 2/15/2023 I = 7.44P 6 D^-0.645 EX-AREA A 100-Year Precipitation (P6) = 2.75 inches 5.00 min 2.75 inches 5.00 min 2.75 inches 5.00 min I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA A 100-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) = 7.25 I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual 100-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) = 7.25 in/hr 3229 HIGHLAND DRIVE Proposed Intensity Calculations 2/15/2023 I = 7.44P 6 D^-0.645 in/hr PROP-AREA B PROP-AREA C 100-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) = 7.25 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual ------ □: D I D I D I D I D I D I D I D I D I D I D I D I D I D I D I D I D I D I D I 35 30 ~ 25 ..r:. .µ c.. QJ 20 -c C: 0 ·.;::; 15 B '5. .., ~ 10 c.. 5 0 C: E I U"l 35 30 c 25 -..r:. .µ c.. ~ 20 C: 0 ·.;::; 15 B '5. -~ 10 c.. 5 0 1 C: .E I 0 r-1 PDS-based depth-duration-frequency (DDF) curves Latitude: 33.1634°, Longitude: -117 .3361 ° • • • I. • • • • , l • • • • • J • • • • • .J • • • J • • • •• J • • • • • •'• • • • • • ~ • • • • • l • • • '• • J • • • • .J • • •'• • • • • • . ' . ' ' ' -. -:---. -. ; . ----·'. ---. --: . -. ~ --. -. -: -. -. -. : ----. -:--. --. ~ . -. :-. -: . --. -: . -. : ------ . -. : ----. -:--. --. ~ . ' ' ' """r"00•··r •····\·····-.•··1·····--.·•····,······i····•r···,··-.·· C: ~ ~ ... ... ... ... ... >, >, >, >, >, >, .E .E .E .r::; .r::; .r::; .r::; .r::; I'll I'll I'll I'll I'll I'll rlJ rri ,.h I I -c -c -c "C -c -c N ~ I I I r-1 rlJ rri s:t I I I U"l 0 0 r--0 0 r-1 rr'l \0 r-1 N Du1ration ·-----•:------------:--------i-·---------:--- . . ·····-············· .. -·-·····1· >, I'll -c I 0 rr'l 2 5 10 25 50 100 200 500 Average recurrence interval (years) >, >, I'll I'll -c -c I I U"lO s;t \0 1000 NOAA Atlas 14, Volume 6, Version 2 Created (GMT): Mon Feb 20 22:07:24 2023 Average recummce inleM'I (years} 1 2 5 10 25 50 100 200 500 1000 Duration 5-min 10-imln 15-<mln 30-mln 60-smln 2-hr 3-hr ·6-t1,r 12-hr 24-hr 2--day 3--day 4-day 7-day 10-day 20-day 30-day 45-day 60-day -Victorville SANe-.E. . -Rlv-4.{' Rivers1.de lJ. z,.IJVo .. • • iYr....,~M B h An ah~1m Ca-thedral tjty lj' Long eac • .. , _ •;e • .. s anta ;A.na • aim D-,iser t Indio rffifBarb,:iro Oxnard 0 Morr1et,a • Oceansi4- • Santa Cl arita I San Diego Ensenada p Salton Se.i Residential Remodel and Associated Site Improvements – 3229 Highland Drive 7 APPENDIX D PROPOSED AREA B DESIGN CAPTURE VOLUME CALCULATIONS 0.90 0.14 0.10 4,008 SF 3,682 SF 1,788 SF 9,478 SF 0.22 ACRES 0.45 211 CF 85th Percentile, 24-hour rainfall (d) = 0.59 IN Design Capture Volume (DCV) = 3229 HIGHLAND RESIDENCE DCV CALCULATIONS 1-Dec-2023 Proposed Design Control Volume Weighted C Factor = Impervious Area = Landscape Area = Permeable Paver Area = Total Area = Total Area = AREA B Roofs, Concrete, or Asphalt (C) = Natural B Soil (C) = Permeable Pavers (C) = Table B.1-1 of the Carlsbad BMP Design Manual updated January 2024 Table B.1-1 of the Carlsbad BMP Design Manual updated January 2024 Residential Remodel and Associated Site Improvements – 3229 Highland Drive 8 APPENDIX E PROPOSED AREA B PAVER SECTION VOLUME CALCULATIONS 1788 SF 3.75 IN 0.31 FT 224 CFVolume Beneath the Underdrain =Assumes 40% Void Ratio Stone Section Beneath the Underdrain = Base Course Thickness = 3229 HIGHLAND RESIDENCE Paver Base Sizing 1-Dec-2023 Pavers - Area B Permeable Paver Area = Residential Remodel and Associated Site Improvements – 3229 Highland Drive 9 APPENDIX F INFILTRATION TESTING REPORT AND PAVER DRAWDOWN TIME CALCULATIONS ~= -=225aS?APPLIED CONSULTANTS geotechnfca/ & forensic engineering JC Collins and Jeannine Woo 2633 Lincoln Blvd, Unit 941 Santa Monica, CA 90405 January 12, 2024 1941-A Friendship Drive El Cajon, CA 92020 TEL (619) 258-9000 www.applied-consultants.com Subject: Updated Infiltration Testing Report for the Subject Property Located at 3229 Highland Drive, Carlsbad, CA, 92008 Dear Mr. Collins & Mrs. Woo, In accordance with your request, we have prepared this Infiltration Testing Report for the property located at the aforementioned address. The purpose of this report was to provide a feasibility analysis for infiltration with respect to geotechnical and groundwater conditions. We performed design phase infiltration testing as part of our study. It is our professional opinion that a design infiltration rate of 0.38 inches per hour may be used for the design ofBMP infiltration devices of this project. The grading plans for the subject property dated December 26, 2023 prepared by John L. Majocha P .E. propose gravel pavement and permeable pavers for driveways and hardscape. The proposed permeable surfaces are mapped adjacent to proposed foundations. Infiltration at these areas can cause reductions in soil strength. In order to prevent reductions in soils strength, the proposed foundations adjacent to permeable pavers and gravel pavement shall be extended or cut-off-walls bottoms shall be constructed such that the foundations or cut-off-walls extend two feet below the bottom of the base rock storage section. Additionally, the proposed permeable pavement is mapped over an existing sewer lateral. In order to prevent damage to sewer utilities from stormwater infiltration, sewer pipes located within ten feet of infiltration areas shall be encased with concrete or steel. We appreciate this opportunity to be of service. Should you have any questions, please call our office at (619) 258-9000. Sincerely, Jorge L. Val. Gonzalez, PE 92051 Project Engineer 3229 Highland Drive -Updated Infiltration Testing Report JLVG/JED 1/12/2024 Page I of 7 1.0 SITE EVALUATION The location of the property is at latitude 33° 9'48"N and longitude 117°20'1 0"W. The subject property is located in a residential neighborhood of Carlsbad, California (Figure 1 ). For the purpose of this report the front of the subject property which faces Highland Dr is assumed to be east. The subject property is bounded on the north by Pine Ave; to the east by Highland Drive; and to west and south by other existing residential dwellings. Review of the current topographic map for the site indicates that the subject property is at approximately 171 feet with respect to the North American Vertical Datum of 1988 (NA VD 88) The subject property is a rectangular shaped parcel of approximately 0.48 acres that moderately slopes (10-15%) from east to west. The lot is currently occupied by an existing one-story wood framed single family residence, a single-story companion unit and a detached garage. The proposed development is the construction of a new two-story residence with a partial daylight basement, a detached single-story ADU and a below grade swimming pool. Based upon the local topography, historical aerials and our subsurface investigation, we feel that the majority of the subject property is underlain by native soils. As part of our study, we reviewed the State of California, State Water Resources Control Board Geotracker system. There are no active cleanup sites or contaminated sites within a 400 feet radius of the subject property. There are no "Brown fields" adjacent to the subject property. According to the County of San Diego Hydrology Manual -Soil Hydrologic Group. The County of San Diego Hydrology Manual categorizes the soils at the subject property as Hydrologic Group B . The Hydrologic Group B is characterized as "Soils have moderate infiltration rate when thoroughly wetted; chiefly soils that are moderately deep to deep, moderately well drained to well drained, and moderately coarse textured. Rate of water transmission is moderate." Groundwater was not encountered during our investigation. Based on our field investigation and review of available published groundwater data and historical information from the monitoring well of project T0608170198 (Geotracker) located 0.3 miles west of the subject property and published from geotechnical exploration performed for project T10000011547 (Geotracker) located 0.4 miles north of the subject property, groundwater is not anticipated to be within 10 feet of the lowest elevation of the site. The properties surrounding the subject property are highly developed with piped water and sewer systems. Based upon the density of the development, there are no water supply wells, septic systems, or underground storage tanks, or permitted gray water systems within 100 feet of the proposed infiltration areas. 3229 Highland Drive - Updated Infiltration Testing Report JLVG/JED 1/12/2024 Page 2 of7 Geographic Location ~~APPLIED CONSULTANTS geotechnical & forensic engmeer,ng 3229 Highland Drive, Carlsbad, CA,92008 GeoTracker Map (1,000 feet radi us) 3229 Highland Drive -Updated Infiltration Testing Report JLVG/JED 1/12/2024 Page 3 of7 i N Fig. 1 Geographic Location Soil Groups CJ GroupA 1111 GroupB CJ Groupe CJ GroupD CJ Undetermined CJ Data Unavailable geolechnical & forensic engineering 3229 Highland Drive, Carlsbad, CA,92008 Soil Hydrology Groups Map County of San Diego 3229 Highland Drive -Updated Infiltration Testing Report JLVG/JED 1/12/2024 Page 4 of7 i N Fig. 2 2.0 SUBSURFACE EXPLORATION 2.1 Initial Field Investigation On May 26, 2022, a representative of this firm visited the site to perform physical reconnaissance and field work at the subject property for purposes of our preliminary geotechnical investigation. Soil samples were taken from the proposed site to be evaluated. We hand augered four borings as part of our reconnaissance. The borings were taken within the subject property to a maximum depth of four feet below grade. Locally the materials encountered are generally: -From grade to fourteen inches below grade a fine to medium grained, loose, reddish brown silty sand (SM) was encountered. -From fourteen inches below grade to forty-eight inches below grade a fine to medium graded, reddish light brown silty sand (SM) was encountered. No ground water was encountered during our site reconnaissance. 3.0 INFILTRATION TESTING On June 22, 2023, a representative of our firm performed infiltration testing with "Borehole Percolation Tests" at the subject property. Four borings were excavated within the area proposed infiltration areas. Location of proposed infiltration areas and elevations are referenced by the grading & drainage plan for the subject property dated December 26, 2023 prepared by John L. Majocha P .E. 3.1 Methodology We performed design phase infiltration testing as part of our study. Four borings were excavated to a maximum depth of two feet at various elevations to perform "Borehole Percolation Tests" for determination of infiltration rates in conformance with the City of Carlsbad BMP Manual. Prior to percolation testing, all borings were filled with water to top of hole for a minimum of four hours. After four hours, the water column was allowed to drop overnight. Our test was performed within 15-30 hours after the initial four-hour presoak. The holes were refilled to approximately top of hole and the rate of fall was measured and recorded for a minimum of six hours, refilling every 30 minutes until consistent result were obtained. Regarding lateral infiltration, the Porchet Correction was applied for the final hour of percolation rates to obtain infiltration rates. 3229 Highland Drive -Updated Infiltration Testing Report JLVG/JED 1/12/2024 Page 5 of7 3.2 Infiltration Test Results On June 22, 2023, Percolation Hand Boring #1 through #4 were tested. Field data for each boring is attached to the report figures. The following table presents the final percolation results converted to infiltration rates: PERCOLATION RATE CONVERSION TO INFILTRATION -PORCHET METHOD (IN/HR) PHB-1 PHB-2 PHB-3 PHB-4 Dt (in) Depth of hole 24.00 24.00 24.00 24.00 Do (in) Initial depth to water 4.00 4.00 4.00 4.00 Df (in) Final depth to water 10.75 11.25 12.50 8.50 Ho (in) 20.00 20.00 20.00 20.00 Hf (in) 13.25 12.75 11.50 15.50 Delta H (in) 6.75 7.25 8.50 4.50 Have (in) 16.63 16.38 15.75 17.75 radius (in) 6.00 6.00 6.00 6.00 Time interval (min) 30.00 30.00 30.00 30.00 Percolation rate (in/hr) 13.50 14.50 17.00 9.00 Infiltration Rate (in/hr) 2.06 2.25 2.72 1.30 The design infiltration rate is = corrected infiltration/ F.S. (Table D.2-3) = 1.3 in/hr/ 3.38 = 0.38 in/hr 4.0 INFILTRATION STUDY CONCLUSIONS We performed design phase infiltration testing as part of our study. It is our professional opinion that a design infiltration rate of 0.38 inches per hour may be used for the design ofBMP infiltration devices of this project. The grading plans for the subject property dated December 26, 2023 prepared by John L. Majocha P.E. propose gravel pavement and permeable pavers for driveways and hardscape. The proposed permeable surfaces are mapped adjacent to proposed foundations. Infiltration at these areas can cause reductions in soil strength. In order to prevent reductions in soils strength, the proposed foundations adjacent to permeable pavers and gravel pavement shall be extended or cut-off-walls bottoms shall be constructed such that the foundations or cut-off-walls extend two feet below the bottom of the base rock storage section. Additionally, the proposed permeable pavement is mapped over an existing sewer lateral. In order to prevent damage to sewer utilities from stormwater infiltration, any sewer pipes located within ten feet of infiltration areas shall be encased with concrete or steel. 3229 Highland Drive -Updated Infiltration Testing Report JLVG/JED 1/12/2024 Page 6 of7 FIGURES AND FIELD DATA 3229 Highland Drive -Updated Infiltration Testing Report JL VG/JED 1/12/2024 Page 7 of7 .APPLIED CONSULTANTS ~t a! 9«)laf1Y ~ f1119lnHrlng PtH& AIIE>IU& LEGEND: ~HB-1 INFILTRATION TEST BORING LOCATION FIGURE 1: INFILTRATION TESTING MAP (GRADING PLAN BASE) 3229 HIGHLAND DRIVE, CARLSBAD, CA 92008 [?;;:.:~;;~~~ oo(::x ~:i~~~~o-~ [!]J· >-Q{ ()(Jr'!f,,,, /"J. fi':i~itSU<RS @JCCWCR!lr P,of)/[llf fi]LG-.Cffl'l' C~9 P(f?' ~(. ,t...!/l' CV.~ I.MJ ;]Pr.vt,H'.( P,Ht"'!' f ".iklllQI.£ C-»STIHC M L]j.RlU"l.f" f»~ ,-.C ~ B: :'UI'.)\.£ {X,Sr,Hf; 1 fil~\.£{Jt!S&i(;}f b.3lM_,.,\.£CXJSr.HC ~/iOIO',f' {Jt1Sr:N(; /)r-,, :~J;Clr.'.)',[' AS/'Htl,J. f (J.<I' ~Rtll'::i~r 02:",N';,, REFERENCE: This map was prepared from a Grading Plan by John Majocha P.E. and from the field investigation performed by APPLIED CONSULTANTS. Date: 7/14/23 Drawn by: JLVG PERCOLATION TESTING FIELD DATA Proiect Name and Test Location: 3229 Hiohland Drive, Carlsbad, CA, 92008 Test pit#: 1 Hole diameter (in): 6 Test By: JV Hole depth (in): 24 Liauid Used: Water USCS Class: SM Date of Test: 6/22/2023 Deoth to Water Table: > 10 feet Liquid Level Maintained by usinq: Manually Additional Comments: Time Time Dt (min) Readings interval (hr:min) & Total Depth to Percolation Rate (in/hr) Remarks Water (in.) ~H (in) 1-Start 9:00 0:30 4.000 14.000 28.000 End 9:30 0:30 18.000 2-Start 9:30 0:30 4.000 12.000 24.000 End 10:00 1:00 16.000 3-Start 10:00 0:30 4.000 9.000 18.000 End 10:30 1:30 13.000 4-Start 10:30 0:30 4.000 9.000 18.000 End 11 :00 2:00 13.000 5-Start 11:00 0:30 4.000 9.000 18.000 End 11:30 2:30 13.000 6-Start 11:30 0:30 4.000 8.500 17.000 End 12:00 3:00 12.500 7-Start 12:00 0:30 4.000 8.500 17.000 End 12:30 3:30 12.500 8-Start 12:30 0:30 4.000 6.750 13.500 End 13:00 4:00 10.750 9-Start 13:00 0:30 4.000 6.750 13.500 End 13:30 4:30 10.750 10-Start 13:30 0:30 4.000 6.750 13.500 End 14:00 5:00 10.750 11-Start 14:00 0:30 4.000 6.750 13.500 End 14:30 5:30 10.750 12-Start 14:30 0:30 4.000 6.750 13.500 End 15:00 6:00 10.750 PERCOLATION TESTING FIELD DATA Project Name and Test Location: 3229 HiQhland Drive, Carlsbad, CA, 92008 Test pit#: 2 Hole diameter (in): 6 Test Bv: JV Hole deoth (in): 24 Liquid Used: Water USCS Class: SM Date of Test: 6/22/2023 Depth to Water Table: > 10 feet Liauid Level Maintained by usina: Manually Additional Comments: Time Time Dt (min) Readings interval (hr:min) & Total Depth to Percolation Rate (in/hr) Remarks Water (in.) LiH (in) 1-Start 9:00 0:30 4.000 14.500 29.000 End 9:30 0:30 18.500 2-Start 9:30 0:30 4.000 12.000 24.000 End 10:00 1:00 16.000 3-Start 10:00 0:30 4.000 11.500 23.000 End 10:30 1:30 15.500 4-Start 10:30 0:30 4.000 9.000 18.000 End 11:00 2:00 13.000 5-Start 11:00 0:30 4.000 9.000 18.000 End 11:30 2:30 13.000 6-Start 11:30 0:30 4.000 8.500 17.000 End 12:00 3:00 12.500 7-Start 12:00 0:30 4.000 8.500 17.000 End 12:30 3:30 12.500 8-Start 12:30 0:30 4.000 7.250 14.500 End 13:00 4:00 11.250 9-Start 13:00 0:30 4.000 7.250 14.500 End 13:30 4:30 11.250 10-Start 13:30 0:30 4.000 7.250 14.500 End 14:00 5:00 11.250 11-Start 14:00 0:30 4.000 7.250 14.500 End 14:30 5:30 11.250 12-Start 14:30 0:30 4.000 7.250 14.500 End 15:00 6:00 11.250 PERCOLATION TESTING FIELD DATA Proiect Name and Test Location: 3229 Hiqhland Drive, Carlsbad, CA, 92008 Test pit#: 3 Hole diameter (in): 6 Test By: JV Hole depth (in): 24 Liquid Used: Water uses Class: SM Date of Test: 6/22/2023 Deoth to Water Table: > 10 feet Liquid Level Maintained by usinq: Manually Additional Comments: Time Time Dt (min) Readings interval (hr:min) & Total Depth to Percolation Rate (in/hr) Remarks Water (in.) ~H (in) 1-Start 9:00 0:30 4.000 11.000 22.000 End 9:30 0:30 15.000 2-Start 9:30 0:30 4.000 11.000 22.000 End 10:00 1:00 15.000 3-Start 10:00 0:30 4.000 10.500 21.000 End 10:30 1:30 14.500 4-Start 10:30 0:30 4.000 10.500 21.000 End 11:00 2:00 14.500 5-Start 11:00 0:30 4.000 10.500 21.000 End 11:30 2:30 14.500 6-Start 11:30 0:30 4.000 10.000 20.000 End 12:00 3:00 14.000 7-Start 12:00 0:30 4.000 10.000 20.000 End 12:30 3:30 14.000 8-Start 12:30 0:30 4.000 9.000 18.000 End 13:00 4:00 13.000 9-Start 13:00 0:30 4.000 8.500 17.000 End 13:30 4:30 12.500 10-Start 13:30 0:30 4.000 8.500 17.000 End 14:00 5:00 12.500 11-Start 14:00 0:30 4.000 8.500 17.000 End 14:30 5:30 12.500 12-Start 14:30 0:30 4.000 8.500 17.000 End 15:00 6:00 12.500 PERCOLATION TESTING FIELD DATA Project Name and Test Location: 3229 Highland Drive, Carlsbad, CA, 92008 Test pit#: 4 Hole diameter (in): 6 Test By: JV Hole depth (in): 24 Liquid Used: Water uses Class: SM Date of Test: 6/22/2023 De_pth to Water Table: > 10 feet Liquid Level Maintained by using: Manually Additional Comments: Time Time Dt (min) Readings interval (hr:min) & Total Depth to Percolation Rate (in/hr) Remarks Water (in.) 6H (in) 1-Start 9:00 0:30 4.000 8.500 17.000 End 9:30 0:30 12.500 2-Start 9:30 0:30 4.000 8.000 16.000 End 10:00 1:00 12.000 3-Start 10:00 0:30 4.000 6.000 12.000 End 10:30 1:30 10.000 4-Start 10:30 0:30 4.000 5.000 10.000 End 11 :00 2:00 9.000 5-Start 11:00 0:30 4.000 4.500 9.000 End 11:30 2:30 8.500 6-Start 11:30 0:30 4.000 4.500 9.000 End 12:00 3:00 8.500 7-Start 12:00 0:30 4.000 4.500 9.000 End 12:30 3:30 8.500 8-Start 12:30 0:30 4.000 4.500 9.000 End 13:00 4:00 8.500 9-Start 13:00 0:30 4.000 4.500 9.000 End 13:30 4:30 8.500 10-Start 13:30 0:30 4.000 4.500 9.000 End 14:00 5:00 8.500 11-Start 14:00 0:30 4.000 4.500 9.000 End 14:30 5:30 8.500 12-Start 14:30 0:30 4.000 4.500 9.000 End 15:00 6:00 8.500 Appendix D: Geotechnical Engineer Analysis endix D Geo echnica E Ana ysis ~nee D.1 Analysis of Infiltration Restrictions This section is only applicable if the analysis of infiltration restrictions is performed by a licensed engineer practicing in geotechnical engineering. The SWQMP Preparer and Geotechnical Engineer must work collaboratively to identify any infiltration restrictions identified in Table D.1-1 below. Upon completion of this section, the Geotechnical Engineer must characterize each DMA as Restricted or Unrestricted for infiltration and provide adequate support/discussion in the geotechnical report. A DMA is considered restricted when one or more restrictions exist which cannot be reasonably resolved through site design changes. Table D.1-1: Considerations for Geotechnical Analysis oflnfiltration Restrictions Restriction Element BMP is within 100' of Contaminated Soils BMP is within 100' of Industrial Activities Lacking Source Control BMP is within 100' of Well/Groundwater Basin BMP is within SO' of Septic Tanks/Leach Fields BMP is within 1 O' of Groundwater Table BMP is within Hydric Soils BMP is within Highly Liquefiable Soils and has Connectivity to Structures BMP is within 1.5 Times the Height of Adjacent Steep Slopes (2':25%) County Staff has Assigned ''Restricted" Infiltration Category BMP is within Predominantly Type D Soil BMP is within 1 0' of Property Line BMP is within Fill Depths of 2':S' (Existing or Proposed) BMP is within 1 0' of Underground Utilities BMP is within 250' of Ephemeral Stream Other (Provide detailed geotechnical support) Based on examination of the best available information, Is Element Applicable? (Yes/No) IIIIDDIIIII I have not identified any restrictions above. Unrestricted Based on examination of the best available information, D I have identified one or more restrictions above. Restricted Table D.1-1 is divided into Mandatory Considerations and Optional Considerations. Mandatory D-1 Jan.2024 Appendix D: Geotechnical Engineer Analysis Considerations include elements that may pose a significant risk to human health and safety and must always be evaluated. Optional Considerations include elements that are not necessarily associated with human health and safety, so analysis is not mandated through this guidance document. All elements presented in this table are subject to the discretion of the Geotechnical Engineer if adequate supporting information is provided. Applicants must evaluate infiltration restrictions through use of the best available data. A list of resources available for evaluation is provided in Section B.2 D.2 er inati 0 sign lnfiltra ion a es This section is only applicable if the determination of design infiltration rates is performed by a licensed engineer practicing in geotechnical engineering. The guidance in this section identifies methods for identifying observed infiltration rates, corrected infiltration rates, safety factors, and design infiltration rates for use in structural BMP design. Upon completion of this section, the Geotechnical Engineer must recommend a design infiltration rate for each DMA and provide adequate support/ discussion in the geotechnical report. Table D.2-1: Elements for Determination of Design Infiltration Rates Item Value Unit - Initial Infiltration Rate qr) Identify per Section D.2.1 in/hr Corrected Infiltration Rate \ ;7:J Identify per Section D.2.2 in/hr Safety Factor Identify per Section D.2.3 ~✓i6 unitless Design Infiltration Rate 0,~i in/hr Corrected Infiltration Rate -;.. Safety Factor D-2 Jan.2023 Consideration Suitability Assessment (A) Design (B) Appendix D: Geotechnical Engineer Analysis Table D.2-3: Determination of Safety Factor Assigned Factor Product (p) Weight (w) Value (v) p=wxv Infiltration Testing Method 0.25 o.s Soil Texture Class 0.25 Refer to o.s Soil Variability 0.25 Table D.2-4 G ,1-S Depth to Groundwater/Obstruction 0.25 O ,J .. C: Suitability Assessment Safety Factor, SA = I:p \ .c; Pretreatment 0.50 \.o Resiliency 0.25 Refer to 0 :~ TableD.2-4 Compaction 0.25 o.~ Design Safety Factor, Sa = I:p L2~ Safety Factor, S = SA x Sa ~,~5 (Must be always greater than or equal to 2) The geotechnical engineer should reference Table D.2-4 below in order to determine appropriate factor values for use in the table above. The values in the table below are subjective in nature and the geotechnical engineer may use professional discretion in how the points are assigned. D-12 Jan.2023 0.38 3.75 0.31 0.40 0.13 4 Design Infiltration Rate (I) = 3229 HIGHLAND RESIDENCE PAVER DRAWDOWN TIME CALCULATIONS 1-Dec-2023 PAVERDRAWDOWN TIME - Section B.3.2 of the Carlsbad BMP Design Manual (Updated January 2024) TR = ED/(I/12) Area B Pavers in/hr in ft Table B.3-1 of the Jan 2024 Carlsbad BMP Manual ft hours Stone Depth Below Underdrain = Stone Depth Below Underdrain = Retention Pore Space Factor = Effective Depth (ED) = Drawdown Time (TR) = Residential Remodel and Associated Site Improvements – 3229 Highland Drive 10 APPENDIX G PIPE CALCULATIONS NORTH ( APN: 205-051-02-00 O' 10 2,0 ' SCALE, 1' = 10' D:\DRA\NING FILES\TllLE SHEETS\GRADING TITLE SHEET.DWG REVISED:02/15/17 ,: X Q C\J X I ~ u X ,: X I I I I AREA Al A2 A3 A4 AS A6 A7 AB A9 Al0 Bl B2 B3 B4 BS B6 B7 BB B9 Bl0 Bll B12 Cl C2 C3 C4 ASSUMPTIONS PROPOSED DESIGN FLD\./S TOTAL AREA (sf) 752 1,232 326 532 135 192 510 346 323 1,203 370 698 555 233 226 196 288 608 374 1,684 279 149 1,113 1,141 1,183 373 TOTAL AREA (ACRES) 0,02 0,03 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,03 0,01 0,02 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,04 0,01 0,01 0,03 0,03 0,03 0,01 TC CMIN) 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 C RUNOFF COEFFICIENT 0,28 0,73 0,27 0,69 0,25 0,25 0,81 0,25 0,25 0,49 0,30 0,68 0,25 0,25 0,25 0,25 0,25 0,41 0,25 0,84 0,78 0,25 0,57 0,55 0,62 0,25 10-YR INTENSITY (IN/HR) 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 4,61 10-YR (cfs) 0,03 0.10 0,01 0,03 0,01 0,01 0,04 0,01 0,01 0,07 0,01 0,06 0,01 0,01 0,01 0,01 0,01 0,02 0,01 0.15 0,04 0,01 0,08 0,08 0,09 0,01 1. TIME OF CONCENTRATION FOR ALL PROPOSED DRAINAGE AREAS ARE ASSUMED TO BE 5 MINUTES OUE TO THEIR SMALL SIZE. 2. COMPOSITE C-VALUE CALCULATED USING C-VALUES OBTAINED FROM TABLE 3-1 OF THE SAN DIEGO COUNTY HYDROLOGY MANUAL. 3. INTENSmES WERE DETERMINED USING [l=7.44'P6•D-(-.645}] PER SECTION 3.1.3 OF THE SAN DIEGO COUNTY HYDROLOGY MANUAL. 4. INTENSITY FOR 10-YEAR EVENT JS BASED ON 10-YR 6-HR PRECIPITATION OF 1.75-/NCHES -PROPOSED 1=4.61 in/hr. 5. PROPOSED INTENSITIES ARE INDICATED IN THE PROPOSED TABLES ABOVE. "AS BUILT" RCE __ _ EXP, ___ _ DATE REVIE'w'ED BY, INSPECTOR DA TE I SH;ET I CITY OF CARLSBAD I SH~ETS I t-----+--+---------------+---+--+---+----1 ENGINEERING DEPARTMENT 1-----+--+---------------+---+--+----+----I 3229 HIGHLAND DRIVE 1-----+--+---------------+---+--+----+----1 GR 2023-0012 PIPE DRAINAGE AREAS DAlE INITIAL DAlE INlllAL DATE INlllAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL APPROVED:JASON S. GELDERT ENGINEERING MANAGER RCE 63912 EXP. 9/30/24 DAlE DWN BY: JLM CHKD BY: JLM RVWD BY: PROJECT NO. PD 2023-0008 DRAWING NO. 541-9A 722 SF 30 SF 752 SF 319 SF 913 SF 1,232 SF 314 SF 12 SF 326 SF Weighted C-Value = 0.27 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) Pervious Area = Impervious Area = Total Area = Total Area = Weighted C-Value = 0.73 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA A3 Pervious Area = Impervious Area = Pervious Area = Impervious Area = Total Area = Weighted C-Value = 0.28 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B 3229 HIGHLAND PIPE C-VALUE CALCULATIONS 1-Dec-2023 PIPE C-VALUES AREA A1 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B AREA A2 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B 175 SF 357 SF 532 SF 135 SF 0 SF 135 SF 192 SF 0 SF 192 SF 68 SF 442 SF 510 SFTotal Area = Weighted C-Value = 0.81 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA A7 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B Pervious Area = Impervious Area = Pervious Area = Impervious Area = Total Area = Weighted C-Value = 0.25 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) Total Area = Weighted C-Value = 0.25 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA A6 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B AREA A5 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B Pervious Area = Impervious Area = Pervious Area = Impervious Area = Total Area = Weighted C-Value = 0.69 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA A4 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B 346 SF 0 SF 346 SF 323 SF 0 SF 323 SF 761 SF 442 SF 1,203 SF Weighted C-Value = 0.49 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) Pervious Area = Impervious Area = Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B Total Area = Total Area = Weighted C-Value = 0.25 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA A10 AREA A9 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B Pervious Area = Impervious Area = Pervious Area = Impervious Area = Total Area = Weighted C-Value = 0.25 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA A8 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B 344 SF 26 SF 370 SF 237 SF 461 SF 698 SF 55 SF 0 SF 55 SF 233 SF 0 SF 233 SFTotal Area = Weighted C-Value = 0.25 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA B4 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B Pervious Area = Impervious Area = Pervious Area = Impervious Area = Total Area = Weighted C-Value = 0.25 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) Total Area = Weighted C-Value = 0.68 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA B3 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B AREA B2 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B Pervious Area = Impervious Area = Pervious Area = Impervious Area = Total Area = Weighted C-Value = 0.30 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA B1 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B 226 SF 0 SF 226 SF 196 SF 0 SF 196 SF 288 SF 0 SF 288 SF 460 SF 148 SF 608 SFTotal Area = Weighted C-Value = 0.41 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA B8 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B Pervious Area = Impervious Area = Pervious Area = Impervious Area = Total Area = Weighted C-Value = 0.25 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) Total Area = Weighted C-Value = 0.25 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA B7 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B AREA B6 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B Pervious Area = Impervious Area = Pervious Area = Impervious Area = Total Area = Weighted C-Value = 0.25 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA B5 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B 374 SF 0 SF 374 SF 165 SF 1,519 SF 1,684 SF 53 SF 226 SF 279 SF 149 SF 0 SF 149 SFTotal Area = Weighted C-Value = 0.25 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA B12 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B Pervious Area = Impervious Area = Pervious Area = Impervious Area = Total Area = Weighted C-Value = 0.78 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) Total Area = Weighted C-Value = 0.84 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA B11 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B AREA B10 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B Pervious Area = Impervious Area = Pervious Area = Impervious Area = Total Area = Weighted C-Value = 0.25 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA B9 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B 569 SF 538 SF 1,107 SF 610 SF 531 SF 1,141 SF 501 SF 682 SF 1,183 SF Pervious Area = Impervious Area = Total Area = Weighted C-Value = 0.62 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) Total Area = Weighted C-Value = 0.55 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA C3 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B AREA C2 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B Pervious Area = Impervious Area = Pervious Area = Impervious Area = Total Area = Weighted C-Value = 0.57 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA C1 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B 373 SF 0 SF 373 SFTotal Area = Weighted C-Value = 0.25 Weighted Runoff Coefficient Equation in Section 3.1.2 of the 2003 San Diego County Hydrology Manual (C=0.90*(% Impervious)+Cp*(1-% Impervious) AREA C4 Pervious Area C-Value (Cp)= 0.25 Per Table 3-1 of the 2003 San Diego County Hydrology Manual , LDR, Soil Type B Pervious Area = Impervious Area = 1.75 inches 5.00 min 1.75 inches 5.00 min 1.75 inches 5.00 min 1.75 inches 5.00 min 1.75 inches 5.00 min in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA A5 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual 10-Year Precipitation (P6) = 3229 HIGHLAND DRIVE Pipe Intensity Calculations 2/15/2023 I = 7.44P 6 D^-0.645 PROP-AREA A1 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA A2 Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA A3 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA A4 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 1.75 inches 5.00 min 1.75 inches 5.00 min 1.75 inches 5.00 min 1.75 inches 5.00 min 1.75 inches 5.00 minDuration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA A9 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA A10 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA A8 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA A6 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA A7 10-Year Precipitation (P6) = 1.75 inches 5.00 min 1.75 inches 5.00 min 1.75 inches 5.00 min 1.75 inches 5.00 min 1.75 inches 5.00 min 1.75 inches 5.00 min Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA B1 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA B2 10-Year Precipitation (P6) = PROP-AREA B3 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA B5 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA B4 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA B6 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual 1.75 inches 5.00 min 1.75 inches 5.00 min 1.75 inches 5.00 min 1.75 inches 5.00 min 1.75 inches 5.00 min 1.75 inches 5.00 min PROP-AREA B7 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA B8 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA B9 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA B10 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA B11 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA B12 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual 1.75 inches 5.00 min 1.75 inches 5.00 min 1.75 inches 5.00 min 1.75 inches 5.00 min PROP-AREA C1 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA C2 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA C3 10-Year Precipitation (P6) = Duration (D) = Rainfall Intensity (I) =4.61 in/hr I = 7.44P6D^-0.645 Figure 3-1 of the San Diego Hydrology Manual PROP-AREA C4 10-Year Precipitation (P6) = Hydraflow DOT Report 1 Line To Line Line Length Incr. Area Total Area Runoff Coeff. Incr C x A Total C x A Inlet Time Time Conc Rnfal Int Total Runoff Adnl Flow Total Flow Capac Full Veloc Pipe Size Pipe Slope Inv Elev Dn Inv Elev Up HGL Dn HGL Up (ft)(ac)(ac)(C)(min)(min)(in/hr)(cfs)(cfs)(cfs)(cfs)(ft/s)(in)(%)(ft)(ft)(ft)(ft) 1 Outfall 26.210 0.00 0.00 0.49 0.00 0.00 5.0 8.3 0.0 0.00 0.07 0.32 0.25 3.67 4 0.99 154.26 154.52 154.59 155.01 2 1 47.790 0.00 0.00 0.25 0.00 0.00 5.0 8.0 0.0 0.00 0.01 0.25 0.27 2.87 4 1.21 154.52 155.10 155.08 155.57 3 2 40.760 0.00 0.00 0.00 0.00 0.00 5.0 7.8 0.0 0.00 0.00 0.24 0.25 2.75 4 1.01 155.10 155.51 155.59 155.97 4 3 2.710 0.00 0.00 0.81 0.00 0.00 5.0 7.8 0.0 0.00 0.04 0.23 0.26 2.64 4 1.11 155.51 155.54 156.09 156.11 5 3 4.340 0.00 0.00 0.25 0.00 0.00 5.0 5.0 0.0 0.00 0.01 0.01 0.27 0.11 4 1.15 155.51 155.56 156.09 156.09 6 4 9.430 0.00 0.00 0.25 0.00 0.00 5.0 7.7 0.0 0.00 0.01 0.19 0.43 2.18 4 3.08 155.54 155.83 156.19 156.25 7 6 35.430 0.00 0.00 0.25 0.00 0.00 5.0 7.4 0.0 0.00 0.01 0.18 0.73 2.37 4 8.81 155.83 158.95 156.30 159.19 8 7 30.490 0.00 0.00 0.27 0.00 0.00 5.0 7.1 0.0 0.00 0.01 0.17 0.54 2.58 4 4.76 158.95 160.40 159.19 160.63 9 8 13.550 0.00 0.00 0.27 0.00 0.00 5.0 7.0 0.0 0.00 0.00 0.16 1.00 2.51 4 16.24 160.40 162.60 160.63 162.83 10 9 16.940 0.00 0.00 0.73 0.00 0.00 5.0 6.8 0.0 0.00 0.10 0.13 1.00 2.21 4 16.23 162.60 165.35 162.83 165.55 11 9 18.980 0.00 0.00 0.02 0.00 0.00 5.0 5.0 0.0 0.00 0.03 0.03 0.35 0.98 4 2.00 162.60 162.98 162.83 163.07 12 10 37.670 0.00 0.00 0.28 0.00 0.00 5.0 5.0 0.0 0.00 0.03 0.03 0.77 1.01 4 9.69 165.35 169.00 165.55 169.09 Hydraflow DOT Report 2 Line Grnd/Rim Dn Grnd/Rim Up Line ID (ft)(ft) 1 154.76 156.78 A10 TO OUTFALL 2 156.78 158.74 A9 TO A10 3 158.74 157.80 4X6 TEE TO A9 4 157.80 157.34 A7 TO 4X6 TEE 5 157.80 156.09 A8 TO 4X6 TEE 6 157.34 157.90 A6 TO A7 7 157.90 161.45 A5 TO A6 8 161.45 164.60 A3 TO A5 9 164.60 166.50 4X4 TEE TO A3 10 166.50 168.60 A2 TO 4X4 TEE 11 166.50 166.40 A4 TO 4X4 TEE 12 168.60 172.02 A1 TO A2 (/) 0 3 (/) <D :E <D ijl I I G) r :::0 CD Q) () ::r 2 0 I\) 0, 0, 0 -.J 0, ~ 0 0 ~ I\) 0, ~ 0, 0 ~ -.J 0, I\) 0 0 I\) I\) 0, I\) 0, 0 I\) -.J 0, ~ .i:,. CXl 0 0 ~ .i:,. CXl 0 0 ;i! ~ "" "'= (§) 8 ~ ~ ~ "" ~ I~ "" e ~ ·~ ~ . (l ~ '~ ~ ~ 0, a, a, .i:,. 0 0 0 0 \ ~ \ --i'\ ~~ : \ to, i,. . '~ "" ~ ~ V / I/ ./ -~ -,-\ ... "'\ ~) ~ \ \ 1 \ I~-~ \ ' ' \ ~ ICE l ~ ~ \ ! ~ ~--,,-1\ ' \ \ ~ (E ,~~ 0 \ 0 -~ I ci \ ' ;: " • II ~ ~ ij t;; ~ ;:,. ~ ~ ~ ~ e" 0 ' .i,.. ,, : D 8) ~ t» '" ~ ~ ~ (i) ~ ,1 i (~ f2-Ii,, ~ r. '"' "' ~ 0, a, 0 <D ~ 0) a, <D .i:,. 'cf2. 6 0 0 ~ -.J I\) 0 0 -, \ \1-1\ \ \ \ .,_ -~-, ~ l ~ ' \ ' \ \ \ ""--- ~ -.J I\) 0 0 \ " \ ~ CXl <:) 0 0 ~ CXl 0 0 0 ~ CXl CXl 0 0 ~ CXl CXl 0 0 m <D < :§ Sta 0+00.00 - Grnd. El. 154. Outfall -6 Inv. El. 154.26 Sta 0+26.21 - Rim El. 156.78 Inv. El. 154.52 Inv. El. 154.52 Sta 0+74.00 -l Rim El. 158.74 Inv. El.155.10 Inv. El. 155. 1 0 Sta 1+14.76-l Grnd. El. 157.e Inv. El. 155.51 Inv. El. 155.51 Sta 1+17.47 -l Rim El. 157.34 Inv. El. 155.54 Inv. El. 155.54 Sta 1 +26.90 -l Rim El. 157.90 Inv. El. 155.83 Inv. El. 155.83 Sta 1 +62.33 -l Rim El.161.45 Inv. El. 158.95 Inv. El. 158.95 Sta 1 +92.B2 -l Rim El. 164.60 Inv. El. 160.40 Inv. El. 160.40 Sta 2+06.37 - l Grnd. El. 166.e Inv. El. 162.60 Inv. El. 162.60 Sta 2+23.31 -l Rim El. 168.60 Inv. El. 165.35 Inv. El. 165.35 Sta 2+60.98 - l Rim El. 172.02 Inv. El. 169.00 n n: 1 Out ·n n: 2 Out ·n n:3 0 Out ·n n:4 Out ·n n:6 Out ·n n:7 Out ·n n:8 Out ·n n:9 0 Out ·n n: 10 Out ·n n: 12 Out CJ) r+ 0 -, 3 CJ) (1) :e (1) -, "'tJ -, 0 ...._ -· (1) iJ .Q, ::::!, ~ I G5 I s;: z 0 (/) -I 0 :::0 s:: 0 :::0 ~ z )> (/) 3 Storm Sewer Profile :i oQE Elev. (ft) IC? 0 0 oigft!«! OT""'NN • CD CD O....,;.T""'T""' 'i"W_:_: ouWW ~E>> C/l C!> E.: 175.00 172.00 169.00 / 166.00 163.00 . • r-.., nnO/~ 10 ..... ---- 160.00 0 10 ----HGL C ....I ' CX) ~ CX) .... + 0 al ci5 :i 0 Ocx, s:1'.m CD • CON .... ~ iiiui .s > a:= 20 30 40 50 60 70 Reach (ft) Proj. file: HIGHLAND STORM DRAIN A.stm 80 90 175.00 172.00 169.00 166.00 163.00 160.00 100 Storm Sewers Storm Sewer Profile Elev. (ft) 168.00 165.00 162.00 159.00 156.00 153.00 :i oQE IX) o~~~ OT""'LOLO • IO IO O....,;.T""'T""' 'i"W_:_: ouWW ~E>> C/l C!> E.: V " \. / \. ( ~ ~ ' II I IO C ..J ' "<t C') -,i 0 + 0 m cii / , ..,._.., .. .., ... , :i 0 mco ~IO (0 • ,o:g ........ iii u:i Ji> a::.= "' ---.. ~ ,., .... ,o 0 10 ----HGL 20 30 40 50 60 Reach (ft) 70 Proj. file: HIGHLAND STORM DRAIN A.stm 80 90 168.00 165.00 162.00 159.00 156.00 153.00 100 Storm Sewers Hydraflow DOT Report 1 Line To Line Line Length Incr. Area Total Area Runoff Coeff. Incr C x A Total C x A Inlet Time Time Conc Rnfal Int Total Runoff Adnl Flow Total Flow Capac Full Veloc Pipe Size Pipe Slope Inv Elev Dn Inv Elev Up HGL Dn HGL Up (ft)(ac)(ac)(C)(min)(min)(in/hr)(cfs)(cfs)(cfs)(cfs)(ft/s)(in)(%)(ft)(ft)(ft)(ft) 1 Outfall 49.260 0.00 0.00 0.25 0.00 0.00 5.0 9.7 0.0 0.00 0.01 0.35 0.29 4.06 4 1.38 157.99 158.67 158.30 159.24 2 1 25.300 0.00 0.00 0.78 0.00 0.00 5.0 9.6 0.0 0.00 0.04 0.34 0.27 3.90 4 1.23 158.67 158.98 159.48 159.96 3 2 16.330 0.00 0.00 0.25 0.00 0.00 5.0 9.5 0.0 0.00 0.01 0.30 0.27 3.44 4 1.22 158.98 159.18 160.20 160.44 4 3 12.990 0.00 0.00 0.41 0.00 0.00 5.0 9.0 0.0 0.00 0.02 0.04 0.35 0.46 4 2.00 159.18 159.44 160.62 160.63 5 4 20.130 0.00 0.00 0.25 0.00 0.00 5.0 7.6 0.0 0.00 0.01 0.02 0.37 0.23 4 2.19 159.44 159.88 160.63 160.63 6 5 17.770 0.00 0.00 0.30 0.00 0.00 5.0 5.0 0.0 0.00 0.01 0.01 0.35 0.11 4 1.97 159.88 160.23 160.63 160.63 7 3 23.430 0.00 0.00 0.25 0.00 0.00 5.0 7.8 0.0 0.00 0.01 0.10 0.25 1.15 4 1.02 159.18 159.42 160.62 160.66 8 7 13.630 0.00 0.00 0.25 0.00 0.00 5.0 7.6 0.0 0.00 0.01 0.09 0.28 1.03 4 1.32 159.42 159.60 160.68 160.70 9 8 19.460 0.00 0.00 0.25 0.00 0.00 5.0 7.2 0.0 0.00 0.01 0.08 0.28 0.92 4 1.28 159.60 159.85 160.71 160.73 10 9 19.510 0.00 0.00 0.68 0.00 0.00 5.0 6.8 0.0 0.00 0.06 0.07 0.25 0.80 4 1.03 159.85 160.05 160.73 160.75 11 10 12.510 0.00 0.00 0.25 0.00 0.00 5.0 5.0 0.0 0.00 0.01 0.01 0.52 0.18 4 4.40 160.05 160.60 160.76 160.76 12 3 13.010 0.00 0.00 0.84 0.00 0.00 5.0 5.0 0.0 0.00 0.15 0.15 0.35 1.72 4 2.00 159.18 159.44 160.62 160.67 Hydraflow DOT Report 2 Line Grnd/Rim Dn Grnd/Rim Up Line ID (ft)(ft) 1 158.49 159.96 B12 TO OUTFALL 2 159.96 161.92 B11 TO B12 3 161.92 162.16 B7 TO B11 4 162.16 162.20 B8 TO B7 5 162.20 162.20 B9 TO B8 6 162.20 162.17 B1 TO B9 7 162.16 162.22 B6 TO B7 8 162.22 162.20 B5 TO B6 9 162.20 162.20 B4 TO B5 10 162.20 162.19 B2 TO B4 11 162.19 162.19 B3 TO B2 12 162.16 162.40 B10 TO B7 Storm Sewer Profile C Elev. (ft) I ~;;; ...J ' 0 :g ~ co 0 .... I'-N • lO ai g w ,-st c!:, -ci ii:i + 0 ,2!E> .s Cl) C) -= Cl) 170.00 167.00 164.00 161.00 -i------------158.00 A" Im ,138% s -· 155.00 0 10 20 30 40 ----HGL =i QC -co I'-I'-~coco CJ) • • lO Cl0 Cl0 ,-~~ iii ii:i ii:i .s > > a::-=-= ~ --~ LiJ.--- 50 60 ~ A" Im 1 ~ ~ N C ...J ' co lO si I'-+ 0 .s Cl) L..---"" f~D/n 70 =i QC -Nco CO ~(J)(J) ,-a:i CX) COio lO ............ iii ii:i ii:i .s > > a::-=-= 80 Reach (ft) ~ l") C ...J ' CJ) co 0 CJ) + 0 m cii =i QC -co co co ~~r: CO CJ) CJ) IOIO ............ iii ii:i ii:i .s > > a::-=-= 16. 330Lf -4" I ..... C ...J ' co co <') 0 + .... m cii =i QC -o,...,... "!vv N .. CO CJ) CJ) IOIO ............ iii ii:i ii:i .s > > a::-=-= IL.cl::IULI ~ 1.22% ' ,.,, '+ \81 L.UI Proj. file: HIGHLAND STORM DRAIN B.stm ...J ' .... 0 si N + .... m cii =i QC -0 coco "!coco N .. co~~ .... ........ iii ii:i ii:i .s >> a::-=-= ' ~ co C ...J ' co I'-: ~ + .... .l!! Cl) =i Q I'-<') '<""'.N N ' cog ........ iii ii:i .s > a::-= 17. l770Lf-4" I~ 1 'lnl f A" I,;;,') 1COL - tO 170.00 167.00 164.00 161 .00 90 100 110 120 130 140 155.00 150 Storm Sewers ~I 3 (J) <D :E <D ijl I G) r :::0 CD Q) 0 ~ 0 I\) 0 (,.) 0 ./>. 0 () 01 ::r 0 2 a, 0 ..... 0 0) 0 co 0 ~ 0 0 ~ 01 ..... 0 0 ( ; l ~ ' a~ i ' I ~ I\) ~ 0 r ' -I'; @ .IS, :i,. 0 'if. ~ 01 ..... 0 0 ~ a, 0 0 0 ! : "' ~ (~ '"" 13 ~ t ' j~ a~ .. -~ ,-1/. ~ ~ .... ' ~ te, 0 t,) :,'!!. .. \ \ , ~ a, 0 0 0 ~ ~ ~ ~ a, a, a, ..... (,.) c:n <O I\) 0 0 0 0 0 0 0 0 I\ ~ ~ ~ ~ a, a, a, ..... (,.) a, co I\) 0 0 0 0 0 0 0 0 m <D < :§ Sta 0+00.00 Rim El. 162.11 Inv. El. 159.1B Inv. El. 159.1B Sta 0+23.43 - Rim El. 162.2: Inv. El. 159.42 Inv. El. 159.42 Sta 0+37.06 - Rim El. 162.2[ Inv. El. 159.60 Inv. El. 159.60 Sta 0+56.52 - Rim El. 162.21 Inv. El. 159.B5 Inv. El. 159.85 Sta 0+76.03 - Rim El. 162.1! Inv. El. 160.05 Inv. El. 160.05 Sta 0+BB.54 - Out In Ln:7 Out In Ln:B Out In Ln:9 Out In Ln: 10 Out In Ln: 11 Out Rim El. 162.19 Inv. El. 160.60 CJ) r+ 0 -, 3 CJ) (1) :e I~ "'tJ -, 0 ...._ -· -(1) iJ .Q, ::::!, ~ I G5 I s;: z 0 (/) -I 0 :::0 s:: 0 :::0 ~ z OJ (/) 3 Storm Sewer Profile Proj. file: HIGHLAND STORM DRAIN B.stm Elev. (ft) 172.00 ~----~----~----~----~----~----~---~~---~----~----~ 172.00 169.00 -+--+------+--+-----------+------+-----+-----+-----------------+-------169.00 166.00 -+--+------+--+-----------+------+-----+-----+-----------------+-------166.00 163.00 -+/--+------+--+-----------+------+-----+-----+-----------------+-------163.00 ~-V ...,._, ---,. ~ "-I'-""' /U 157.00 ~----~----~----~----~----~----~---~~---~----~----~157.00 0 10 20 30 40 50 60 70 80 90 100 ----HGL Reach (ft) Storm Sewers Hydraflow DOT Report 1 Line To Line Line Length Incr. Area Total Area Runoff Coeff. Incr C x A Total C x A Inlet Time Time Conc Rnfal Int Total Runoff Adnl Flow Total Flow Capac Full Veloc Pipe Size Pipe Slope Inv Elev Dn Inv Elev Up HGL Dn HGL Up (ft)(ac)(ac)(C)(min)(min)(in/hr)(cfs)(cfs)(cfs)(cfs)(ft/s)(in)(%)(ft)(ft)(ft)(ft) 1 Outfall 32.730 0.00 0.00 0.25 0.00 0.00 5.0 5.9 0.0 0.00 0.01 0.26 0.23 3.15 4 0.89 168.99 169.28 169.27 169.60 2 1 23.490 0.00 0.00 0.62 0.00 0.00 5.0 5.7 0.0 0.00 0.09 0.25 0.27 2.98 4 1.15 169.28 169.55 169.63 169.84 3 2 31.060 0.00 0.00 0.55 0.00 0.00 5.0 5.5 0.0 0.00 0.08 0.16 0.25 2.19 4 1.00 169.55 169.86 169.94 170.09 4 3 25.210 0.00 0.00 0.57 0.00 0.00 5.0 5.0 0.0 0.00 0.08 0.08 0.19 1.58 4 1.03 169.86 170.12 170.10 170.28 Hydraflow DOT Report 2 Line Grnd/Rim Dn Grnd/Rim Up Line ID (ft)(ft) 1 169.49 171.18 C4 TO OUTFALL 2 171.18 171.45 C3 TO C4 3 171.45 171.50 C2 TO C3 4 171.50 171.52 C1 TO C2 Storm Sewer Profile I ~;;; a~~ o..--co • co g w r- c!:, -ci ii:i Elev. (ft) ,2!E> Cl) C) -= 182.00 179.00 176.00 173.00 ---170.00 / ---------- 3 . f;jULf -.q, \!! u ..... "',o 167.00 0 10 20 ----HGL C ...J ' M I'-; N M + a 19 Cl) 30 :i QC -co co co -r:NN T"9 CJ) 0) t--co co .................. iiJ ii:i ii:i -~ > > a::-=-= ~o •• Ill f -4• (ru 1 15% 40 50 N C ...J ' N N co LO + a 19 Cl) :i QC - LO LO LO 'SI: LOLO ~mm t--co co .................. iiJ ii:i ii:i -~ > > a::-=-= 60 -,) I.UOUL --. ""' 70 Reach (ft) 80 M C ...J ' co N ~ co + a llJ en Proj. file: HIGHLAND STORM DRAIN C.stm :i QC -0 coco ~coco T"""aiCD t--co co .................. iiJ ii:i ii:i -~ > > a::.=.= '>'-?10Lf -4" (a} 1.03"/o 90 100 '<I' C ...J ' m '<I' C'\i + ..-- llJ en 110 :i Q NN ~ ...... ..--c::i ........ ..--...... iiJ ii:i -~ > a::.= 182.00 179.00 176.00 173.00 170.00 167.00 120 Storm Sewers Residential Remodel and Associated Site Improvements – 3229 Highland Drive 11 APPENDIX H SWALE CALCULATIONS NORTH APN: 205-051-02-00 D:\DRA\NING FILES\TllLE SHEETS\GRADING TITLE SHEET.DWG REVISED:02/15/17 7J ,, 0100=0.0XCFS v,100=1 .. 'JFPS . I I ~ )7J ) ,:,, • ( :' I I AREA A I I Q C\J X Q X C:', I / ':·) / Lt-) •.-._ / ;' C-2 ,( X ,( X Q X Q X Q X Q X Cl X X I • L • u. +I? U_v? X " I l ) () I 0 ,( X l,l ' c:r_ X ,( X ,(, ,( X C_, X ,( X ,( X I I -------1 r-,c ,c I X X I I I I I ;1 I I I I I I I I I I I I I I I I I PROPOSED DESIGN FL □~S AREA TOTAL AREA Csf) TOTAL AREA CACRES) TC CMIN) C RUNOFF COEFFICIENT 100-YR INTENSITY CIN/HR) 100-YR Ccfs) A 1,696 0,04 5,0 0,25 7,25 0,07 ASSUMPTIONS 1. TIME OF CONCENTRATION FOR ALL PROPOSED DRAINAGE AREAS ARE ASSUMED TO BE 5 MINUTES DUE TO THEIR SMALL SIZE. 2. COMPOSITE C-VALUE CALCULATED USING C-VALUES OBTAINED FROM TABLE 3-1 OF THE SAN DIEGO COUNTY HYDROLOGY MANUAL. 3. INTENSmES WERE DETERMINED USING [l=7.44'P6•D-(-.645}] PER SECTION 3.1.3 OF THE SAN DIEGO COUNTY HYDROLOGY MANUAL. 4. INTENSITY FOR 100-YEAR EVENT IS BASED ON 100-YR 6-HR PRECIPITATION OF 2.75-INCHES -PROPOSED 1=7.25 in/hr. 5. PROPOSED INTENSITIES ARE INDICATED IN THE PROPOSED TABLES ABOVE. O' 10 2,0 -- ' SCALE, I' = 10' "AS BUILT" RCE __ _ EXP, ___ _ REVIE'w'ED BY, DATE INSPECTOR DA TE t---+-----+-------------+---+----+---+----t I SH!ET I CITY OF CARLSBAD I SH~ETS I :==::::::'....::::::=:::EN:::G::::I=NE:::E::::R:::IN=G::::::::D:::E=PA:::R=T=M:::E=NT==:::::'....'.==::::::: 3229 HIGHLAND DRIVE 1---+-----11------------------+---+---t---t-----1 GR 2023-0012 PROPOSED SWALE DRAINAGE AREA APPROVED:JASON S. GELDERT DAlE INITIAL DAlE INlllAL DAlE INlllAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL ENGINEERING MANAGER DWN BY: JLM CHKD BY: JLM RVWD BY: RCE 63912 EXP. 9/30/24 DAlE PROJECT NO. PD 2023-0008 DRAWING NO. 541-9A Channel Report Hydraflow Express Extension for Autodesk® Civil 3D® by Autodesk, Inc.Sunday, Mar 24 2024 EAST SWALE ADJACENT TO WALL Triangular Side Slopes (z:1) = 3.00, 3.00 Total Depth (ft) = 0.25 Invert Elev (ft) = 173.10 Slope (%)= 2.30 N-Value = 0.025 Calculations Compute by:Known Q Known Q (cfs) = 0.07 Highlighted Depth (ft)= 0.13 Q (cfs)= 0.070 Area (sqft)= 0.05 Velocity (ft/s)= 1.38 Wetted Perim (ft) = 0.82 Crit Depth, Yc (ft) = 0.13 Top Width (ft)= 0.78 EGL (ft)= 0.16 0 .5 1 1.5 2 2.5 Elev (ft)Depth (ft)Section 172.75 -0.35 173.00 -0.10 173.25 0.15 173.50 0.40 173.75 0.65 174.00 0.90 Reach (ft) ~ ~ ~ - ............. -V ----- "-/ -