Loading...
HomeMy WebLinkAboutPS 2024-0047; PRANA; Sign Permits/Programs (PS) P-11 Page 1 of 2 Rev. 3/22 Development Services Planning Division 1635 Faraday Avenue (442) 339-2610 www.carlsbadca.gov SIGN PERMIT P-11 SUBMIT ONLINE THIS APPLICATION IS TO BE SUBMITTED ELECTRONICALLY. VISIT OUR ONLINE PERMIT PORTAL AT HTTPS://EG.CARLSBADCA.GOV/. NO PROCESSING WILL BEGIN UNTIL CITY HAS RECEIVED ALL REQUIRED SUBMITTAL ITEMS Background For land use permitting and requirements on signs, refer to chapter 21.41 of the Carlsbad Municipal Code, including an applicable specific plan, master plan or sign program. Depending on the scope of construction, a building permit may also be required. Please note ground-mounted/monument signs within the coastal zone also require a minor Coastal Development Permit. Requirements for signs may be subject to an existing sign program on file with the city. Have questions? Please visit the city website on options to contact Planning. TYPE OF PERMIT APPLYING FOR: Sign Permit (Also use for Temporary Banners and ground mounted/monument signs) Sign Program or Modified Sign Program? Use P-11(D) Name of Project: Related Planning Case Number(s), if any: PROPERTY OWNER/PROPERTY MANAGER APPLICANT NAME (PRINT OR TYPE) NAME (PRINT OR TYPE) MAILING ADDRESS MAILING ADDRESS CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE SIGNATURE DATE Attached SIMON authorization P-11 Page 2 of 2 Rev. 3/22 SUBMITTAL REQUIREMENTS: PRIOR TO PERMIT PROCESSING, APPLICANT MUST SUBMIT ALL ITEMS BELOW: 1. Sign/Site Plans Application for sign permits require plans be submitted consisting of a minimum of a title sheet, site plan and sign elevations containing the following information*: 1. Project Name 2. Site Address 3. Applicants contact information: Name, address, phone number and email 4. North arrow and scale. 5. Location of existing buildings or structures, parking areas, and vehicular access points to the property. For monument/ground mounted signs, provide location of the sign relative to existing driveways, easements, objects, mature landscaping, and city right-of-way. 6. Location of all existing and proposed signs for the property. 7. Distance to the property line(s) for all proposed freestanding sign(s). 8. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area (square feet) for all existing and proposed sign(s). B. Materials and color the sign(s) will be constructed of. C. Type of mounting D. Source of Illumination, if any. E. Proposed sign copy (text/lettering/design of proposed sign). *Additional supporting information may be required from applicant depending on standards, requirements, scope, design and/or property constraints. 2. Certificate of Accuracy, form P-37, signed/executed 3. Completed/signed application form 4. Application Fee (Invoiced/paid after application screened) P-37 Page 1 of 1 Rev. 2/2022 Development Services Planning Division 1635 Faraday Avenue (442) 339-2610 www.carlsbadca.gov Certificate of Accuracy P-37 Project Name__________________________ Type of permit(s) applying for____________________________ CITY OF CARLSBAD - PLANNING DIVISION CERTIFICATE OF ACCURACY I certify all documents and plans clearly and accurately show all existing and all proposed buildings, structures, access roads, and utilities/utility easements. All proposed land use activities, improvements to land, and/or building modifications or additions are clearly labeled on the site plan of the approved plan set. I understand that any potentially existing detail within these plans inconsistent with the site plan are not approved and may be required to be altered or removed. The submitted documents and plans show the correct dimensions of the property, the buildings, and structures and their setbacks from property lines and from one another, access roads/easements, and utilities. The existing and proposed use of land and of each building as stated is true and correct. Further, all improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. All easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. Applicant: _______ Date: _____________ 2208 Riding Ridge Rd. Columbia, SC 29223 803-530-3255 www.Signwav.com PROJECT: PAGE TITLE: DRAWING DATE: CLIENT: CLIENT APPROVAL: APPROVAL DATE: PROJECT # SHEET:1/7 Cover Columbia Sportswear Company NOTE: This drawing supersedes all drawings with dates prior to the date of this drawing. 11 July 2024 Carlsbad Premium Outlets 5600 Paseo Del Norte Space #A126 Carlsbad, CA 92008 SWE24-050 URGENT: ATTENTION ELECTRICIANSSign Transformer requires that allcircuits must have dedicated hot,neutral ground, terminating at panel.Questions: call 803.530.3255 SIGN MUST BE GROUNDED IN COMPLIANCE WITH ARTICLE 600OFTHE NATIONAL ELECTRIC CODE. CIRCUITS REQUIREDOne [ 1 ] 20 AMP120 VOLT circuitdedicatedto sign ONLYREQUIRED PS2024-0047 JUSTYN CHAMBERLAIN 8/1/2024 14-916 03/20/15 LR/EK ST CALIFORNIA 162 ISSUED FOR LANDLORD REVIEW SITE PLAN 1/64" = 1'-0" Sign Location Plan - NTS 2208 Riding Ridge Rd. Columbia, SC 29223 803-530-3255 www.Signwav.com PROJECT: PAGE TITLE: DRAWING DATE: CLIENT: CLIENT APPROVAL: APPROVAL DATE: PROJECT # SHEET: Project Location Details Columbia Sportswear CompanyColumbia Sportswear Company NOTE: This drawing supersedes all drawings with dates prior to the date of this drawing. Location Map Site Plan Aerial View 11 July 2024 Carlsbad Premium Outlets 5600 Paseo Del Norte Space #A126 Carlsbad, CA 92008 SWE24-050 prAna SPACE # A126 AA Primary Sign A Blade Sign B 41 ' - 1 0 " AP P R O X . L E A S E L I N E T O L E A S E L I N E 2/7 URGENT: ATTENTION ELECTRICIANSSign Transformer requires that allcircuits must have dedicated hot,neutral ground, terminating at panel.Questions: call 803.530.3255 SIGN MUST BE GROUNDED IN COMPLIANCE WITH ARTICLE 600OF THE NATIONAL ELECTRIC CODE. CIRCUITS REQUIREDOne [ 1 ] 20 AMP120 VOLT circuitdedicatedto sign ONLYREQUIRED Storefront Elevation AA - 1/4” = 1’-0” ***NOTE 2: ALL SIGN AREA DIMENSIONS PROVIDED FOR REFERENCE ONLY BASED ON SCALING! SIGN TO BE CENTERED ON SIGN AREA (LEFT-TO-RIGHT & TOP-TO-BOTTOM) AS SHOWN. ***NOTE: AFF dimension provided for reference only! Sign to be centered vertically on sign area. 2208 Riding Ridge Rd. Columbia, SC 29223 803-530-3255 www.Signwav.com PROJECT: PAGE TITLE: DRAWING DATE: CLIENT: CLIENT APPROVAL: APPROVAL DATE: PROJECT # SHEET: Elevation Columbia Sportswear CompanyColumbia Sportswear Company NOTE: This drawing supersedes all drawings with dates prior to the date of this drawing. 11 July 2024 Carlsbad Premium Outlets 5600 Paseo Del Norte Space #A126 Carlsbad, CA 92008 SWE24-050 3/7 URGENT: ATTENTION ELECTRICIANSSign Transformer requires that allcircuits must have dedicated hot,neutral ground, terminating at panel.Questions: call 803.530.3255 SIGN MUST BE GROUNDED IN COMPLIANCE WITH ARTICLE 600OF THE NATIONAL ELECTRIC CODE. CIRCUITS REQUIREDOne [ 1 ] 20 AMP120 VOLT circuitdedicatedto sign ONLYREQUIRED B.5 B.3 A5 AA LE A S E L I N E LE A S E L I N E 0'-0" A.F.F.T.O. FINISH FLOOR 8'-11 1/4" A.F.F.T.O. STOREFRONT 14'-4 3/4" A.F.F.B.O. PARAPET 18'-2 1/2" A.F.F.B.O. PARAPET EXISTING STOREFRONT GLAZING TO REMAIN.GC TO CLEAN TO LIKE NEW CONDITION EXISTING STOREFRONT GLAZING TO REMAIN.GC TO CLEAN TO LIKE NEW CONDITIONEXISTING STOREFRONT GLAZING TO REMAIN.GC TO CLEAN TO LIKE NEW CONDITIONNEW PRANA BLADE SIGN - TYP.EXISTING STOREFRONT DOOR, DOOR HARDWARE TOREMAIN. GC TO CLEAN TO LIKE NEW CONDITION. 5'-3"5'-5 3/4"6'-0"5'-5 1/2"5'-2 3/4" 17'-6 1/4"3'-2 1/2"5'-4 3/4"2'-11 3/4"3'-2 1/4" EXISTING EXTERIOR FACADE TO REMAIN. GC TO PROTECTAS REQUIRED DURING CONSTRUCTION - TYP.EXISTING EXTERIOR FACADE TO REMAIN. GC TO PROTECTAS REQUIRED DURING CONSTRUCTION - TYP. PREVIOUS TENANT SIGNAGE TO BE REMOVED. EXISTING EXTERIOR FACADE TOREMAIN. GC TO PATCH AND REPAIR AS REQUIRED DURING CONSTRUCTION - TYP. 5'-5 3/4" 8'- 0 " 1 3 / 4 " 1'- 8 " 1 3 / 4 " 6'- 1 0 " 1 3 / 4 " 1"1"1 3/4"1 3/4"1 3/4"1 3/4"1"1" 1 3 / 4 " 1'- 8 " 1 3 / 4 " 6'- 1 0 " 1 3 / 4 " 1 3 / 4 " 1'- 8 " 1 3 / 4 " 6'- 1 0 " 1 3 / 4 " 1 3 / 4 " 1'- 8 " 1 3 / 4 " 6'- 1 0 " 1 3 / 4 " 4 3 / 4 " 5'- 8 1 / 2 " 10 1 / 2 " 4"2'-3 3/4"4 1/4"4 1/4"2'-3 3/4"4" 1 3 / 4 " 1'- 8 " 1 3 / 4 " EQ EQ CL EQEQCL Blade Sign AB ** * +/ - 1 0 ’ - 6 ” A F F NOTE: Sign A is installed on curved facade. A B NOTE: Preliminary rendering! Survey required to confirm facade area. 2208 Riding Ridge Rd. Columbia, SC 29223 803-530-3255 www.Signwav.com PROJECT: PAGE TITLE: DRAWING DATE: CLIENT: CLIENT APPROVAL: APPROVAL DATE: PROJECT # SHEET: Rendering Columbia Sportswear CompanyColumbia Sportswear Company NOTE: This drawing supersedes all drawings with dates prior to the date of this drawing. 11 July 2024 Carlsbad Premium Outlets 5600 Paseo Del Norte Space #A126 Carlsbad, CA 92008 SWE24-050 4/7 URGENT: ATTENTION ELECTRICIANSSign Transformer requires that allcircuits must have dedicated hot,neutral ground, terminating at panel.Questions: call 803.530.3255 SIGN MUST BE GROUNDED IN COMPLIANCE WITH ARTICLE 600OF THE NATIONAL ELECTRIC CODE. CIRCUITS REQUIREDOne [ 1 ] 20 AMP120 VOLT circuitdedicatedto sign ONLYREQUIRED URGENT: ATTENTION ELECTRICIANSSign Transformer requires that allcircuits must have dedicated hot,neutral ground, terminating at panel.Questions: call 803.530.3255 SIGN MUST BE GROUNDED IN COMPLIANCE WITH ARTICLE 600OF THE NATIONAL ELECTRIC CODE. CIRCUITS REQUIREDOne [ 1 ] 20 AMP120 VOLT circuitdedicatedto sign ONLYREQUIRED 2208 Riding Ridge Rd. Columbia, SC 29223 803-530-3255 www.Signwav.com PROJECT: PAGE TITLE: DRAWING DATE: CLIENT: CLIENT APPROVAL: APPROVAL DATE: PROJECT # SHEET: Sign Details Columbia Sportswear Company NOTE: This drawing supersedes all drawings with dates prior to the date of this drawing. 11 July 2024 Carlsbad Premium Outlets 5600 Paseo Del Norte Space #A126 Carlsbad, CA 92008 SWE24-050 Sign Elevation - 1” = 1’-0” Sign Sq. Ft. = 25.33A 5/7 General Notes • Signage will be comprised of a fabricated seamless .125" thick aluminum face & returns with push-through face-lit graphics on face. • All exposed surfaces of the cabinet will be primed with reduced etching primer, and painted with low VOC polyurethane enamel, to match RAL 9005 Jet Black (satin finish). • 3/16” sanded Lexan back. • Interior sign cabinet to be painted StarBrite reflective White. • Face of cabinet will be router cut for push-thru graphics. • "prAna" logo graphic letters will be 1" thick white acrylic components, pushed through and protruding 3/4" through the face of the cabinet. • 6500K Bitro LED modules, Mounted to Lexan Back facing into cabinet for face and halo illumination. [ no hot spots ] • Cabinet will have tented weep holes, to prevent light leakage. • There will be no registered trademarks installed on exposed sign surface. • UL labels to be installed on top of cabinet out of view of public. • Installation contractor will determine the number of anchors required, and will seal all penetrations according to Tenant Sign Criteria. • Remote transformers will be mounted behind wall facade within 20 feet [MAX] of sign. • Primary electrical feed to be provided by others (verify if existing can be reused). • Sign to be mounted to facade with 1/4”-20 zip toggles with 3/8” diameter x 2-1/2” long spacers painted to match facade (TBD), installed in pre-drilled mounting holes with clear silicone. (NO VISIBLE FASTENERS). • Quantity: [ 1 ] sign cabinet Sign Section - NTS 4”2-1/2” 3/16” sanded Lexan back Existing storefront finish 4" deep Fabricated Aluminum Cabinet, Painted to match RAL 9005 Jet Black (satin finish) 2x2x1/8 aluminum L angle internal framing 1” thick White Acrylic Letter w/ 3/4” Push-Through Projection Interior sign cabinet to be painted StarBrite reflective White Waterproof sign disconnect switch Countersunk flush fasteners in top & bottom return of cabinet face to secure face to back Minimum of 2” from bottom of sign cabinet Tented weep holes at lowest point of sign cabinet 1/4”-20 zip toggles with 3/8” dia x 3/4” long stand-off spacers painted to match wall (TBD). Install with clear silicone in pre-drilled mounting holes. Transformer located inside junction box on inside of storefront bulkhead. G.C. to provide access panel at junction box location for access to back of sign. NOTE: Wireway may be required on back side of wall. Verify w/survey to determine location for transformer that is not visible to customers. 6500K Bitro LED modules, Mounted to Aluminum Back facing into cabinet for face and halo illumination. [ no hot spots ] .125" thick Aluminum Face & returns, face routed for Push-Though Letters Secondary wire feeds to sign cabinet through water-tight flexible conduit. Seal all penetrations water tight with clear silicone during installation. 16 ” 38 ” 5’-4-15/16” 8’-0” Simulated Night View - NTS URGENT: ATTENTION ELECTRICIANSSign Transformer requires that allcircuits must have dedicated hot,neutral ground, terminating at panel.Questions: call 803.530.3255 SIGN MUST BE GROUNDED IN COMPLIANCE WITH ARTICLE 600OF THE NATIONAL ELECTRIC CODE. CIRCUITS REQUIREDOne [ 1 ] 20 AMP120 VOLT circuitdedicatedto sign ONLYREQUIRED 2208 Riding Ridge Rd. Columbia, SC 29223 803-530-3255 www.Signwav.com PROJECT: PAGE TITLE: DRAWING DATE: CLIENT: CLIENT APPROVAL: APPROVAL DATE: PROJECT # SHEET: Blade Sign Details Columbia Sportswear Company NOTE: This drawing supersedes all drawings with dates prior to the date of this drawing. Blade Sign Elevation - 1”= 1’-0” Blade Sign Letter Detail - 3”= 1’-0” Quantity: [ 1 ] ONE Double Sided Blade Sign Quantity: [ 1 ] ONE Double Sided Blade Sign 1.5” Blade Sign Section - NTS McMaster Carr 31665T1 - NTS McMaster Carr 31665T1 tie-down ring with self-tapping mechanical fasteners into aluminum frame, paint Satin Black 1/8” thick White acrylic 1/8” thick White acrylic Internal aluminum framing 1.5” deep aluminum blade sign panel painted to match RAL 9005 Jet Black (satin finish) on all exposed surfaces SPECIFICATIONS Depth: 1.5” deep aluminum blade sign panel painted to match RAL 9005 Jet Black (satin finish) on all exposed surfaces with 1/8” thick White acrylic CNC/Laser Cut logo on each side. Illumination: NONE Mounting: Eye Bolts/Carabiners Environment: Outdoor NOTES: Survey required to verify existing bracket (if existing) or attachment method to soffit. Quantity: [ 1 ] B 36” EQ EQ 24 ” 18” Max Weight 16lbs CL EQEQ CL Carabiner style attachment clip 1.5” deep aluminum blade sign panel painted to match RAL 9005 Jet Black (satin finish) on all exposed surfaces. 7. 4 ” 30” 11 July 2024 Carlsbad Premium Outlets 5600 Paseo Del Norte Space #A126 Carlsbad, CA 92008 SWE24-050 6/7 McMaster Carr 31665T1 tie-down ring with self-tapping mechanical fasteners into aluminum frame, paint Satin Black 1.5x1.5x.125 Aluminum C channel frame .080” aluminum faces painted Satin to match RAL 9005 “Jet Black” edges of exposed frame painted Satin to match RAL 9005 “Jet Black” NOTE: Ensure clean edges. If necessary, fill, sand, prime and paint. As long as edges of faces blend into inner frame neatly, filling may not be necessary. McMaster Carr 90420A330 8-18 SS No.8x1/2” self tapping fasteners [ 8 ] URGENT: ATTENTION ELECTRICIANSSign Transformer requires that allcircuits must have dedicated hot,neutral ground, terminating at panel.Questions: call 803.530.3255 SIGN MUST BE GROUNDED IN COMPLIANCE WITH ARTICLE 600OF THE NATIONAL ELECTRIC CODE. CIRCUITS REQUIREDOne [ 1 ] 20 AMP120 VOLT circuitdedicatedto sign ONLYREQUIRED 2208 Riding Ridge Rd. Columbia, SC 29223 803-530-3255 www.Signwav.com PROJECT: PAGE TITLE: DRAWING DATE: CLIENT: CLIENT APPROVAL: APPROVAL DATE: PROJECT # SHEET: Blade Sign Details Columbia Sportswear Company NOTE: This drawing supersedes all drawings with dates prior to the date of this drawing. LORD 201 urethane adhesive LORD 304-1 / 304-2 epoxy adhesive 1/8” thick White acrylic logo 11 July 2024 Carlsbad Premium Outlets 5600 Paseo Del Norte Space #A126 Carlsbad, CA 92008 SWE24-050 7/7