Loading...
HomeMy WebLinkAboutPS 2024-0046; STANDARD CONSTRUCTION; Sign Permits/Programs (PS) P-37 Page 1 of 1 Rev. 2/2022 Development Services Planning Division 1635 Faraday Avenue (442) 339-2610 www.carlsbadca.gov Certificate of Accuracy P-37 Project Name__________________________ Type of permit(s) applying for____________________________ CITY OF CARLSBAD - PLANNING DIVISION CERTIFICATE OF ACCURACY I certify all documents and plans clearly and accurately show all existing and all proposed buildings, structures, access roads, and utilities/utility easements. All proposed land use activities, improvements to land, and/or building modifications or additions are clearly labeled on the site plan of the approved plan set. I understand that any potentially existing detail within these plans inconsistent with the site plan are not approved and may be required to be altered or removed. The submitted documents and plans show the correct dimensions of the property, the buildings, and structures and their setbacks from property lines and from one another, access roads/easements, and utilities. The existing and proposed use of land and of each building as stated is true and correct. Further, all improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. All easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. Applicant: _______ Date: _____________ Stand Sign Permit Matthew Kenney (Kenney Signs)07/16/2024 P-29 Page 1 of 2 07/11 Development Services Planning Division 1635 Faraday Avenue (442) 339-2610 www.carlsbadca.gov PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 DATE: 7/30/2024 PROJECT NAME: STANDARD CONSTRUCTION APN: 212-092-3900 PLAN CHECK NO: PS2024-0046 SET#: 1 ADDRESS: 5864 OWENS AVE UNIT 200 This plan check review is complete and has been APPROVED by the PLANNING Division. By: JUSTYN CHAMBERLAIN A Final Inspection by the PLANNING Division is required Yes No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to applicant’s email and are available online at: Carlsbad's Customer Self Service Portal For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 442-339-2610 ENGINEERING 442-339-2750 FIRE PREVENTION 442-339-2665 Justyn Chamberlain 442-339-5104 Justyn.Chamberlain@carlsbadca.gov P-29 Page 2 of 2 07/11 Development Services Planning Division 1635 Faraday Avenue (442) 339-2610 www.carlsbadca.gov PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Comment: PLEASE REVISE SHEET 3 OF PLANS TO CONFORM TO THE SIGN PROGRAM FOR “PALOMAR HEIGHTS” [PAGE 3] WHICH REQUIRES ¾ INCH PEGGING FOR LETTER SIGNS [IMAGES BELOW]: 1 COLOR DISCLAIMER Due to the limitations of desktop scanners and the relative inconsistencies of various display monitors and printers, the colors you see on your screen or on paper may not be a totally accurate reproduction of the actual product. We strive to make our colors as accurate as possible, but screen and printed images are intended as a guide only and should not be regarded as absolutely correct. Site conditions and onsite lighting can also affect how the product appears (i.e. LED, different Florescent bulbs, Natural Light, Backlit, Halolit, Facelit). We recommend that you request a color sample as CMYK (Cyan, Magenta, Yellow and Black) are the colors used in the printing process, whereas RGB (Red, Green and Blue) are the colors used by screen displays such as your monitor. For this reason and due to variations introduced by light and various equipment, the colors on your screen or a print may not exactly match the finished product. If you would like to see a sample of any color, please request an actual sample from your Salesperson or Project Manager. WITHOUT A SIGNED COLOR SAMPLE, KENNEY SIGNS, ITS VENDORS AND AFFILIATES ARE NOT RESPONSIBLE FOR DIFFERENCES, REAL OR PERCEIVED, BETWEEN THE WAY YOUR PRODUCT APPEARS ON SCREEN OR PAPER AND THE FINAL PRODUCT. Client Name (Please Print) _________________________ Date ____/____/____ Client Name (Signature) ____________________________________________ PLEASE INITIAL ALL PAGES Pages: 6 (Including Cover Sheet) Approved Revise & Resubmit Approved as Noted Rejected Conceptual Package Production Package Permit Package A C Scope of Work / Contents: 3 Sign Description Sign Number Page PUSH THROUGH CABINET $3100 SIGN TYPE SIGN NUMBER QTY SQ FTILLUM 22.4201REVERSE-LIT CHANNEL LETTERS WITH PUSH THROUGH LOGO YA Sign Schedule: REVERSE-LIT CHANNEL LETTERS WITH PUSH THROUGH LOGO STANDARD CONSTRUCTION Prepared for: Project Address: 5864 Owens Avenue, Suite 200 Carlsbad, CA 92008 United States Tenant: STANDARD CONSTRUCTION 5864 Owens Avenue, Suite 200 Carlsbad, CA 92008 United States McKenzie Murrey 760-277-5650 mckenzie@standardcnst.com Property Owner / Landlord: STANDARD CONSTRUCTION 5864 Owens Avenue, Suite 200 Carlsbad, CA 92008 United States McKenzie Murrey 760-277-5650 mckenzie@standardcnst.com Legal Description: APN Number: 2120923900 Legal Description: LOT 2\ From: Matt Kenney cell: 760-213-4220 email: matt@relicsigns.com Landlord (Please Print) _________________________ Date ____/____/____ Landlord (Signature) ____________________________________________ + City Fee’s (billed at cost) +California Sales Tax tbd 1420 GRAND AVE SUITE B & C SAN MARCOS, CA 92078 760-459-1119 C-45 LIC.#1082555 PS2024-0046 JUSTYN CHAMBERLAIN 8/1/2024 2 NORTH SITE MAP This is an original unpublished drawing created by KENNEY SIGNS. It is submitted for your personal use in conjunction with a project being planned for you by KENNEY SIGNS. It is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied or exhibited in any fashion without written permission from KENNEY SIGNS STANDARD CONSTRUCTION 5864 Owens Avenue, Suite 200 Carlsbad, CA 92008 1420GRANDAVE SUITEB SANMARCOS,CA92078 760-459-1119 C-45Lic.#1082555 file path: \\ADS11\Design\ADS Drawings\Widget Control Center\job 12345\ Client:Project:Revisions:Project No: Date: Sign Type: Sheet No: 00 00 00 240507 2024-05-30 05/30/24 document title: 11x 17HorizTitleblock20190103a LINEAR FOOTAGE 23’ 84’ LI N E A R F O O T AG E A 3 NIGHTVIEW OPTION B - REVERSE LIT CHANNELS WITH PUSH THROUGH LOGO - QTY: [01] SCALE:NTSB SIGN A This is an original unpublished drawing created by KENNEY SIGNS. It is submitted for your personal use in conjunction with a project being planned for you by KENNEY SIGNS. It is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied or exhibited in any fashion without written permission from KENNEY SIGNS STANDARD CONSTRUCTION 5864 Owens Avenue, Suite 200 Carlsbad, CA 92008 1420GRANDAVE SUITEB SANMARCOS,CA92078 760-459-1119 C-45Lic.#1082555 file path: \\ADS11\Design\ADS Drawings\Widget Control Center\job 12345\ Client:Project:Revisions:Project No: Date: Sign Type: Sheet No: 00 00 00 240507 2024-05-30 05/30/24 document title: 11x 17HorizTitleblock20190103a ThissignisintendedtobeinstalledinaccordancewiththerequirementsofArticle600oftheNationalElectricalCodeand/orotherapplicablelocalcodes.Thisincludespropergroundingandbondingofthesign. ____ Dedicated ____ Amp Circuit at _____ Volts201201 REQUIREMENTSFORELECTRICALILLUMINATION:E-Note #1: All requirements not in sign company’s scope of work must be in place prior to installation. E-Note #2: Electrical to be brought to base of sign(by others) and not in sign company's scope of work. E-Note #3: Timers and/or photocells for signs to be furnished and installed by the customer's electrician, who should also ensure that the completed electrical system is code compliant. ALL COMPONENTS TO BE APPROVED ALL SIGNS TO BE LISTEDThelocationofthedisconnectswitchafterinstallationshallcomplywith Article600.6(A)(1)oftheNationalElectricalCode. WHITE - LED POWER SUPPLY DISCONNECT PRIMARY POWER WITHIN 6’ (BY OTHERS) 1 5 6 7 1 12 5 6 7 15 11 3/4” 17 1 12 5 15 11 17 9 10 REVERSE LIT CHANNEL LETTERS *HARDWARE NOTE LAG BOLT, TOGGLE BOLT OR SHEET METAL SCREWS DEPENDING ON WALL CONDITIONS. MINIMUM 4 PER LETTER SEALED TO PREVENT MOISTURE 9 MOUNTING HARDWARE (4 PER LETTER)* 10 ¼” DRAIN HOLES IN BACK OF LETTERS 11 .040 ALUM. RETURNS 12 .125 ALUM. FACES 15 .177 LEXAN BACKS 17 WEATHER-PROOF ELECTRICAL PASS-THROUGH 18 PUSH THROUGH ACRYLIC (ON LOGO ONLY) 18 2'-0" 11'-2 1/2" 2'-5 3/4" 0'-11" 0'-7 1/4" QUANTITY:ONE (1) OVERALL HEIGHT: 2’-0” OVERALL LENGTH: 11’-2 1/2” RETURNS: 3” .063” ALUMINUM PAINTED SILVER FACE:.125” ALUMINUM PAINTED SILVER (LOGO TO HAVE 1/2” ACRYLIC PUSH THROUGH W/ VINYL) VINYL:LOGO - 3M 3630-22 BLACK ILLUMINATION:WHITE LEDS BACKS:.177” CLEAR POLY AREA: 22.42 ft² 4 OPTION A - REVERSE LIT CHANNELS WITH PUSH THROUGH LOGO - QTY: [01]A ELEVATION A This is an original unpublished drawing created by KENNEY SIGNS. It is submitted for your personal use in conjunction with a project being planned for you by KENNEY SIGNS. It is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied or exhibited in any fashion without written permission from KENNEY SIGNS STANDARD CONSTRUCTION 5864 Owens Avenue, Suite 200 Carlsbad, CA 92008 1420GRANDAVE SUITEB SANMARCOS,CA92078 760-459-1119 C-45Lic.#1082555 file path: \\ADS11\Design\ADS Drawings\Widget Control Center\job 12345\ Client:Project:Revisions:Project No: Date: Sign Type: Sheet No: 00 00 00 240507 2024-05-30 05/30/24 document title: 11x 17HorizTitleblock20190103a SCALE:3/16”=1’