Loading...
HomeMy WebLinkAbout1672 AMANTE CT; ; CBR2022-1412; PermitBuilding Permit Finaled Print Date: 05/07/2024 Job Address: 1672 AMANTE CT, Permit Type: B~DG-Residential Parcel#: 2159004500 Valuation: $41,912.00 Occupancy Group: R3/U #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: 2019 Sprinkled: Project Title: VENIER RESIDENCE Residential Permit CARLSBAD, CA 92011-4041 Work Class: Pool Track#: Lot#: Project#: DEV2022-0l 71 Plan#: Construction Type:VB Orig. Plan Check #: Plan Check#: Permit No: Status: ( City of Carlsbad CB 2022-1412 Closed -Finaled Applied: 04/22/2022 Issued: 07/12/2023 Fina led Close Out: 05/07/2024 Final Inspection: 04/11/2024 INSPECTOR: Alvarado, Tony Renfro, C ris Description: VENIER: PATIO COVER (270 SF)//RET WALL//POOL REMODEL//GAS & ELECTRIC FOR BBQ & FIREPLACE Applicant: Property Owner: CARRIE JONES 9921 CARMEL MOUNTAIN RD, # STE 189 SAN DIEGO, CA 92129-2898 VENIER FAMILY TRUST 08-31-17 1672 AMANTE CT (619) 343-5908 FEE BUILDING PLAN CHECK FEE (manual) BUILDING PLAN CHECK FEE (manual) CARLSBAD, CA 92011-4041 BUILDING PLAN REVIEW -MINOR PROJECTS (LDE) BUILDING PLAN REVIEW -MINOR PROJECTS (PLN) PATIO -FRAME WITH COVER PLUMBING, MECHAN ICAL & ELECTRICAL PERMITS RETAINING WALL -NON-ENGINEERED -CITY STANDARD SB1473-GREEN BUILDING STATE STANDARDS FEE STRONG MOTION -RESIDENTIAL (SM IP) SWIMMING POOL -RESIDENTIAL SWPPP INSPECTION FEE TIER 1 -Medium BLDG SWPPP PLAN REVIEW FEE TIER 1 -Mediur'n Total Fees: $1,549.65 Total Payments To Date: $1,549.65 Balance Due: AMOUNT $120.00 $148.20 $194.00 $98.00 $100.00 $193.00 $100.00 $2.00 $5.45 $228.00 $292.00 $69.00 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance w ith Carlsbad Municipal Co e Section 3.32 .030. Failure t o timely follow that procedure will ba r any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to an y fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov Cicyof CarlsDad RESIDENTIAL BUILDING PERMIT APPLICATION 8-1 Plan Check CJ3j?2oU-JlJ/'2_. Est. Value 'ti,· qa,_ ,,--- ,;[ ~::;,;;_a PC Deposit Date Job Address _Unit: ____ APN:_c)_\_--_q_(X) __ -'-t_._.f'"_-0) __ CT/Project #: ________________ Lot #: ____ Vear Built: ________ _ Fire Sprinklers: 0,EsQNo Air Conditioning:Q YESQ NO BRIEF DESCRJe_TION OF WORK: Pt;h~ Covl,.r I Cl\ Electrical Panel Upgrade:OYESQNO b-l ~r v-el 1 / foo\ ~ G {e \1:>1 ~ b 1=-. \o~ New SF : _____ Living SF, ___ Deck SF, ___ Patio SF,--""'----=-,__Garage SF __ _ Is this to create an Accessory Dwelling Unit? QY ON New Fireplace? QY ON, if yes how many? __ D Remodel: ____ SF of affected area Is the area a conversion or chanff of use? Ov ON D Pool/Spa: ____ SF Additional Gas or Electrical Features? l)0~\~, f"1'ff \c.c..C: OSolar: ___ KW, ___ Modules, Mounted:ORoof OGround, Tilt: OvO N, RMA: Qy ON, Battery:Ov ON, Panel Upgrade: Ov ON D Reroof: _______________________________ _ D Plumbing/Mechanical/Electrical El)only: Other: L= kt w c.l \ c,-t1 $1:c( l~~ L -1. M'Y \.i 5t 1:/; ~e-l ~· '°"'"1) .etQ>\ PRIMARY ~CANA-. _ J PROPERTV~'?'NER Name: ~rie .~ Name: vC.Vl,(,_/ Address: f'j :[l 3 M I O I :>I\ Cei\s=o:f!.,(. Addres-s:-..... l ..... b"l__,, ..... _d-----,x-~-...... fe.-......... -c----.-t _____ _ City: S'.P t: . State: Cf" Zip: J -e)-l vf' City: Uf' ls..~ State: CA Zip: C/;?f) i I Phone: V l ~ ... 3¼ 3 'J'r 6t Phone: Email: C'Sfi•,.-M•tS<>/yla~d ("~ Email:----------------- DESIGN PROFESSIONAL CONTRACTOR OF RECORD Name: ________________ Business Address: Addre ... s5.:----"l~--------~'.lr""""----=~----r---- City: _______ State: ___ .Zip: ____ City:_.....;....\J_,,.;,,_,,.... ........ ..._,..,-· Phone: Phone: --E J)-½..Q Email: Email: Con!,!;ltY'e,,;e c,\l•c~ Architect State License: CSLB License#: [lJ @bOI) Class:._c=;rJ'---"-~ ----- Carlsbad Business License# (Required): ______ _ APPLICANT CERT/FICA T/ON: I certify tha t I have read the application and state that the above information is correct and that the information on the plans; accurate. /agree to comply with all City or • nces and State laws relating to building construction. f\' ~ J / NAME (PRINT): 'C(_✓ /',C,,, \JC SIGN:__.....;l""'"'-------DATE: t( ( t<; "c)c) 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Fax: 760-602-85S8 Email: Building@carlsbadca.gov REV. 07/21 nt?i-1}\ peu_,~/Ol--t THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _ A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LITTER IS REQUIRED P IOR TO PERMIT ISSUANCE. (OPTION A): LICENSED CONTRACTOR DECLARATION: I herebyaffirm under penalty of perjury that I am /icensedunderprovisionsof Chapter9 (commencing with Section 7000)of Division 3 of the Business and Professions Code, and my license is in full force and effect. I a/so affirm under penalty of perjury one of the fol lowing declarations (CHOOSE ONE): Di have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit ls issued. PollcyNo. _____________________________________ _ -OR- DI have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit Is issued. My workers' compensation insurance carrier and policy number are: lnsuranceCompany Name: ____________________ _ Policy No. __________________________ Expiration Date: ______________ _ 'tdJOR- ~ertificate of Exemption: I certify that in the performance of the work for which this permit is Issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject a employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: ____________________ Lender's Address: ___________________ _ CONTRACTOR CERT/FICA TION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. /agree to comply with all City ordinances and State laws relating to buildi g construction. NAME (PRINT): Cov r•e 1eceJ SIGNATURE: ~ DATE: -----------------------------Note: If the person signing above is an authorized agent for the contractor provide a letter of authorization on contractor letterhead. -OR - (OPTION 8): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: [9 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not Intended or off ere for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or Improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). -OR- DI, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). -OR- DI am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: A 0, D FORM 8·61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner. By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors./ understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is submitted orat the following Web site: http://www.leginfo.ca.gov/calaw.html. OWNER CERTIFICATION: lcertifythatlhaveread the applicationandstate that theaboveinformation is correct and that the information on the plans is accurate. /agree to comply with all City ordinances and State laws relating to building construction. NAME (PRINT}: SIGN: __________ DATE: _____ _ Note: If the person signing above is an authorized agent for the property owner Include form B·6Z signed by property owner. 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442·339·2719 Fax: 760-602-BSSB Email: Bullding@carlsbadca.gov 2 REV. 07/21 Building Permit Inspection History Finaled ( City of Carlsbad Permit Type: Work Class: Status: Scheduled Date 08/11/2023 PERMIT INSPECTION HISTORY for {CBR2022-1412) BLDG-Residential Pool Closed -Finaled Actual Inspection Type Start Date 08/11/2023 BLDG-11 Foundation/Ftg/Piers (Rebar) Checklist Item Application Date: 04/22/2022 Issue Date: 07/12/2023 Expiration Date: 06/17/2024 IVR Number: 40192 Inspection No. Inspection Status 220397-2023 Passed COMMENTS Owner: TRUST VENIER FAMILY TRUST 08-31-17 Subdivision: CARLSBAD TCT#92-03 AVIARA PHASE 03 UNIT#04 Address: 1672 AMANTE CT CARLSBAD, CA 92011-4041 Primary Inspector Reinspection Inspection Tony Alvarado Complete Passed BLDG-Building Deficiency City CMU block retaining wall with slope surcharge, engineered fireplace, and engineered, freestanding patio structure - foundation, fooling, steel. reinforcement rebarrebar-approved. Yes BLDG-SW-Inspection 220506-2023 Partial Pass Tony Alvarado Reinspectio Incomplete Tuesday, May 7, 2024 Page 1 of 12 PERMIT INSPECTION HISTORY for (CBR2022-1412) Permit Type: BLDG-Residential Application Date: 04/22/2022 Owner: TRUST VENIER FAMILY TRUST 08-31-17 Work Class: Pool Issue Date: 07/12/2023 Subdivision: CARLSBAD TCT#92-03 AVIARA PHASE 03 UNIT#04 Status: Closed -Finaled Expiration Date: 06/17/2024 Address: 1672 AMANTE CT IVR Number: 40192 CARLSBAD, CA 92011-4041 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed Are inactives slopes properly Yes stabilized? Are areas flatter than 3:1 Yes covered or protected? Are sediment controls properly Yes maintained? Are erosion control BMPs Yes functioning properly? Are natural areas protected Yes from erosion? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Have materials collected Yes around the storm drains? Has sediment accumulated on Yes impervious surfaces? Are dumpsters and trash Yes receptacles covered? Has trash/debris accumulated Yes throughout the site? Are stockpiles and spoils Yes protected from runoff? Are ail storage areas clean Yes and maintained? Were spills/leaks observed Yes during the inspection? Were there any discharges Yes during the inspection? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? Are BMPs stockpiled for Yes emergency deployment? 09/07/2023 09/07/2023 BLDG-21 223236-2023 Partial Pass Tony Alvarado Relnspectlon Incomplete Underground/Underflo or Plumbing Tuesday, May 7, 2024 Page 2 of 12 PERMIT INSPECTION HISTORY for (CBR2022-1412) Permit Type: BLDG-Residential Work Class: Poot Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item Application Date: 04/22/2022 Owner: TRUST VENIER FAMILY TRUST 08-31-17 Issue Date: 07/12/2023 Subdivision: CARLSBAD TCT#92-03 AVIARA PHASE 03 UNIT#04 Expiration Date: 06/17/2024 Address: 1672 AMANTE CT IVR Number: 40192 CARLS BAD, CA 92011-4041 Inspection No. Inspection Primary Inspector Reinspection Inspection Status COMMENTS Passed BLDG-Building Deficiency September 7, 2023: Yes Tuesday, May 7, 2024 BLDG-66 Grout Checklist Item 1. CMU, block retaining wall, located the rear side of the property, grout lift inspection-approved. 2. retaining wall, drain pipe, filter, fabric, and gravel inspected-Ok. 3. SWPPPS and BM PS-sediment and erosion control devices installed -OK. 223093-2023 COMMENTS Partial Pass Tony Alvarado BLDG-Building Deficiency September 7, 2023: BLDG-SW-Inspection 1. CMU, block retaining wall, located the rear side of the property, grout lift inspection-approved. 2. retaining wall, drain pipe, filter, fabric, and gravel inspected-Ok. 3. SWPPPS and BMPS-sediment and erosion control devices installed -OK. 223238-2023 Partial Pass Tony Alvarado Reinspectioh Incomplete Passed Yes Reinspection Incomplete Page 3 of 12 PERMIT INSPECTION HISTORY for (CBR2022-1412) Permit Type: BLDG-Residential Application Date: 04/22/2022 Owner: TRUST VENIER FAMILY TRUST 08-31 -17 Work Class: Pool Issue Date: 07/12/2023 Subdivision: CARLSBAD TCT#92-03 AVIARA PHASE 03 UNIT#04 Status: Closed -Finaled Expiration Date: 06/17/2024 Address: 1672 AMANTE CT IVR Number: 40192 CARLSBAD, CA 92011-4041 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed Are inactives slopes properly Yes stabilized? Are areas flatter than 3:1 Yes covered or protected? Are sediment controls properly Yes maintained? Are erosion control BMPs Yes functioning properly? Are natural areas protected Yes from erosion? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Have materials collected Yes around the storm drains? Has sediment accumulated on Yes impervious surfaces? Are dumpsters and trash Yes receptacles covered? Has trash/debris accumulated Yes throughout the site? Are stockpiles and spoils Yes protected from runoff? Are all storage areas clean Yes and maintained? Were spills/leaks observed Yes during the inspection? Were there any discharges Yes during the inspection? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? Are BMPs stockpiled for Yes emergency deployment? 09127/2023 09/27/2023 BLDG-12 Steel/Bond 225346-2023 Passed Tony Alvarado Complete Beam Tuesday, May 7, 2024 Page 4 of 12 PERMIT INSPECTION HISTORY for (CBR2022-1412) Permit Type: BLDG-Residential Application Date: 04/22/2022 Owner: TRUST VENIER FAMILY TRUST 08-31 -17 Work Class: Pool Issue Date: 07/12/2023 Subdivision: CARLSBAD TCT#92-3 AVIARA Status: Scheduled Date 10/16/2023 PHASE 03 UNIT#04 Closed -Finaled Expiration Date: 06/17/2024 IVR Number: 40192 Address: 1672 AMANTE CT CARLSBAD, CA 92011-4041 Actual Inspection Type Start Date Checklist Item Inspection No. COMMENTS Inspection Primary Inspector Status BLDG-Building Deficiency September 27. 2023: footing, steel. reinforcement approved. For detached patio structure. 10/16/2023 BLDG-23 Gas/Test/Repairs Checklist Item 1. (2) footings, 32" x 32" x 36" deep (4) number #4 steel reinforcement rebar each way -OK. Per structural engineer's plans and detail specifications. 226999-2023 Partial Pass Tony Alvarado COMMENTS BLDG-Building Deficiency Underground gas plumbing lines, and electrical conduit lines for existing inground, gunite swimming pool remodel and new freestanding, wood patio engineered structure and outdoor masonry fireplace, scope of work -plumbing, and electrical, underground conduit and lines-OK. BLDG-31 Underground/Conduit - Wiring Checklist Item 227142-2023 Partial Pass Tony Alvarado COMMENTS BLDG-Building Deficiency Underground gas plumbing lines. and electrical conduit lines for existing inground, gunite swimming pool remodel and new freestanding, wood patio engineered structure and outdoor masonry fireplace, scope of work -plumbing, and electrical, underground conduit and lines-OK. BLDG-SW-Inspection 227145-2023 Partial Pass Tony Alvarado Reinspection Inspection Passed Yes Reinspectio Incomplete Passed Yes Reinspection Incomplete Passed Yes Relnspectlon Incomplete Tuesday, May 7, 2024 Page 5 of 12 PERMIT INSPECTION HISTORY for (CBR2022-1412) Permit Type: BLDG-Residential Application Date: 04/22/2022 Owner: TRUST VENIER FAMILY TRUST 08-31-17 Work Class: Pool Issue Date: 07/12/2023 Subdivision: CARLSBAD TCT#92-03 AVIARA PHASE 03 UNIT#04 Status: Closed -Finaled Expiration Date: 06/17/2024 Address: 1672 AMANTE CT CARLSBAD, CA 92011-4041 IVR Number: 40192 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed Are inactives slopes properly Yes stabilized? Are areas flatter than 3:1 Yes covered or protected? Are sediment controls properly Yes maintained? Are erosion control BMPs Yes functioning properly? Are natural areas protected Yes from erosion? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Have materials collected Yes around the storm drains? Has sediment accumulated on Yes impervious surfaces? Are dumpsters and trash Yes receptacles covered? Has trash/debris accumulated Yes throughout the site? Are stockpiles and spoils Yes protected from runoff? Are all storage areas clean Yes and maintained? Were spills/leaks observed Yes during the inspection? Were there any discharges Yes during the inspection? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? Are BMPs stockpiled for Yes emergency deployment? 10/31/2023 10/31/2023 BLDG-51 228891-2023 Partial Pass Chris Renfro Re inspection Incomplete Excav/Steel(Pools) Checklist Item COMMENTS Passed BLDG-Building Deficiency Partial pass on pool renovation portion. Spa Yes add on excavation and steel on separate permit. Tuesday, May 7, 2024 Page 6 of 12 PERMIT INSPECTION HISTORY for (CBR2022-1412) Permit Type: BLOG-Residential Application Date: 04/22/2022 Owner: TRUST VENIER FAMILY TRUST 08-31-17 Work Class: Pool Issue Date: 07/12/2023 Subdivision: CARLSBAD TCT#92-03 AVIARA Status: Scheduled Date 11/06/2023 PHASE 03 UNIT#04 Closed -Finaled Expiration Date: 06/17/2024 IVR Number: 40192 Address: 1672 AMANTE CT CARLSBAD, CA 92011-4041 Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Status BLDG-52 Pool Plumbing 228892-2023 Partial Pass Chris Renfro Checklist Item BLDG-Building Deficiency COMMENTS Pool plumbing for Pool remodel, Spa added on separate permit, plumbing ok 11/06/2023 BLDG-14 229474-2023 Partial Pass Tony Alvarado Frame/Steel/Bolting/We lding (Decks) Checklist Item BLDG-Building Deficiency COMMENTS November 6, 2023 1. Missing A-35 metal connector clips, ST -18 metal connector straps, on structural engineered plan sheet S-4, structural details, number #3 and number #4, not built per structural engineers plan. 2. The rest of Construction built framing for new freestanding engineered patio wood structure -OK .. BLDG-15 Roof/ReRoof (Patio) 229622-2023 Partial Pass Tony Alvarado Checklist Item COMMENTS BLDG-Building Deficiency BLDG-SW-Inspection 229625-2023 Partial Pass Tony Alvarado Reinspection Inspection Reinspectio Passed Yes Reinspectio Passed Yes Incomplete Incomplete Reinspection Incomplete Passed Yes Reinspecti n Incomplete Tuesday, May 7, 2024 Page 7 of 12 PERMIT INSPECTION HISTORY for (CBR2022-1412) Permit Type: BLDG-Residential Application Date: 04/22/2022 Owner: TRUST VENIER FAMILY TRUST 08-31-17 Work Class: Pool Issue Date: 07/12/2023 Subdivision: CARLSBAD TCT#92-03 AVIARA PHASE 03 UNIT#04 Status: Closed -Finaled Expiration Date: 06/17/2024 Address: 1672 AMANTE CT CARLSBAD, CA 92011-4041 Scheduled Date 12/11/2023 12/20/2023 IVR Number: Actual Inspection Type Start Date Inspection No. Checklist Item Are inactives slopes properly stabilized? Are areas flatter than 3:1 covered or protected? Are sediment controls properly maintained? Are erosion control BMPs functioning properly? Are natural areas protected from erosion? Are perimeter control BMPs maintained? Is the entrance stabilized to prevent tracking? Have sediments been tracked on to the street? Have materials collected around the storm drains? Has sediment accumulated on impervious surfaces? Are dumpsters and trash receptacles covered? Has trash/debris accumulated throughout the site? Are stockpiles and spoils protected from runoff? Are all storage areas clean and maintained? Were spills/leaks observed during the inspection? Were there any discharges during the inspection? Are portable restrooms properly positioned? Do portable restrooms have secondary containment? Are BMPs stockpiled for emergency deployment? COMMENTS 12/11/2023 BLDG-54 Equipotential 232967-2023 Bond(Pools) Checklist Item COMMENTS BLDG-Building Deficiency 12/20/2023 BLDG-55 234437-2023 Fence/Prep laster Tuesday, May 7, 2024 40192 Inspection Primary Inspector Reinspection Inspection Status Passed Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Passed Tony Alvarado Complete Passed Yes Passed Tony Alvarado Complete Page 8 of 12 PERMIT INSPECTION HISTORY for (CBR2022-1412) Permit Type: BLDG-Residential Application Date: 04/22/2022 Owner: TRUST VENIER FAMILY TRUST 08-31-17 Work Class: Pool Issue Date: 07/12/2023 Subdivision: CARLSBAD TCT#92-03 AVIARA PHASE 03 UNIT#04 Status: Closed -Finaled Expiration Date: 06/17/2024 Address: 1672 AMANTE CT IVR Number: 40192 CARLSBAD, CA 92011-4041 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-SW-Inspection 234449-2023 Partial Pass Tony Alvarado Reinspectio Incomplete Checklist Item COMMENTS Passed Are inactives slopes properly Yes stabilized? Are areas flatter than 3:1 Yes covered or protected? Are sediment controls properly Yes maintained? Are erosion control BMPs Yes functioning properly? Are natural areas protected Yes from erosion? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Have materials collected Yes around the storm drains? Has sediment accumulated on Yes impervious surfaces? Are dumpsters and trash Yes receptacles covered? Has trash/debris accumulated Yes throughout the site? Are stockpiles and spoils Yes protected from runoff? Are all storage areas clean Yes and maintained? Were spills/leaks observed Yes during the inspection? Were there any discharges Yes during the inspection? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? Are BMPs stockpiled for Yes emergency deployment? 03/29/2024 03/29/2024 BLDG-Final Inspection 243630-2024 Failed Chris Renfro Reinspection Incomplete Tuesday, May 7, 2024 Page 9 of 12 PERMIT INSPECTION HISTORY for (CBR2022-1412) Permit Type: BLDG-Residential Work Class: Pool Status: Closed -Finaled Scheduled Actual Inspection Type Date Start Date Checklist Item Application Date: 04/22/2022 Owner: TRUST VENIER FAMILY TRUST 08-31-17 Issue Date: 07/12/2023 Subdivision: CARLSBAD TCT#92-03 AVIARA PHAS E 03 UNIT#04 Expiration Date: 06/17/2024 Address: 1672 AMANTE CT CARLSBAD, CA 92011-4041 IVR Number: 40192 Inspection No. Inspection Primary Inspector Reinspection Inspection Status COMMENTS Passed BLDG-Building Deficiency Not ready. No plans or permit card on site. No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No 04/11/2024 04/11/2024 BLDG-Final Inspection 244856-2024 Passed Tony Alvarado Complete Checklist Item COMMENTS Passed BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes BLDG-SW-Inspection 245024-2024 Passed Tony Alvarado Complete Tuesday, May 7, 2024 Page 10 of 12 I PERMIT INSPECTION HISTORY for (CBR2022-1412) Permit Type: BLDG-Residential Application Date: 04/22/2022 Owner: TRUST VENIER FAMILY TRUST 08-3 1-17 Work Class: Pool Issue Date: 07/12/2023 Subdivision: CARLSBAD TCT#92-03 AVIARA PHASE 03 UNIT#04 Status: Closed -Finaled Expiration Date: 06/17/2024 Address: 1672 AMANTE CT CARLSBAD, CA 92011-4041 Scheduled Date IVR Number: Actual Inspection Type Start Date Inspection No. Checklist Item Are inaclives slopes properly stabilized? Are areas flatter than 3:1 covered or protected? Are sediment controls properly maintained? Are erosion control BMPs functioning properly? Are natural areas protected from erosion? Are perimeter control BMPs maintained? Is the entrance stabilized to prevent tracking? Have sediments been tracked on to the street? Have materials collected around the storm drains? Has sediment accumulated on impervious surfaces? Are dumpsters and trash receptacles covered? Has trash/debris accumulated throughout the site? Are stockpiles and spoils protected from runoff? Are all storage areas clean and maintained? Were spills/leaks observed during the inspection? Were there any discharges during the inspection? Are portable restrooms properly positioned? Do portable restrooms have secondary containment? Are BMPs stockpiled for emergency deployment? COMMENTS Tuesday, May 7, 2024 40192 Inspection Primary Inspector Reinspectio Inspection Status Passed Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Page 11 of 12 PERMIT INSPECTION HISTORY for (CBR2022-1412) Permit Type: BLDG-Residential Application Date: 04/22/2022 Owner: TRUST VENIER FAMILY TRUST 08-31 -17 Work Class: Pool Issue Date: 07/12/2023 Subdivision: CARLSBAD TCT#92-03 AVIARA PHASE 03 UNIT#04 Status: Closed -Finaled Expiration Date: 06/17/2024 Address: 1672 AMANTE CT CARLSBAD, CA 92011-4041 Scheduled Date IVR Number: Actual Inspection Type Start Date Inspection No. Checklist Item Are inactives slopes properly stabilized? Are areas flatter than 3:1 covered or protected? Are sediment controls properly maintained? Are erosion control BMPs functioning properly? Are natural areas protected from erosion? Are perimeter control BMPs maintained? Is the entrance stabilized to prevent tracking? Have sediments been tracked on to the street? Have materials collected around the stonm drains? Has sediment accumulated on impervious surfaces? Are dumpsters and trash receptacles covered? Has trash/debris accumulated throughout the site? Are stockpiles and spoils protected from runoff? Are all storage areas clean and maintained? Were spills/leaks observed during the inspection? Were there any discharges during the inspection? Are portable restrooms properly positioned? Do portable restrooms have secondary containment? Are BMPs stockpiled for emergency deployment? COMMENTS Tuesday, May 7, 2024 40192 Inspection Status Primary Inspector Reinspection Inspection Passed Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Page 12 of 12 Transmittal Letter February 15, 2023 City of Carlsbad Community Development Department -Building Division 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review: Residential Patio Cover/ Pool Remodel Address: 1672 Amante Ct, Carlsbad CA Applicant Name: Carrie Jones Applicant Email: cjpermitservice@gmail.com rfr11e No rth COMPLIANC S RVIC S FIRST REVIEW City PennitNo: CBR2022-1412 True North No.: 22-18-088 True North Compliance Services, Inc. has completed the first review of the following documents for the project referenced above on behalf of the City of Carlsbad: 1. 2. Drawings: Electronic copy dated January 24, 2023, by CJ Designs. Structural Calculations: Electronic copy dated, by Daniel Korntved. Attn: Permit Technician, the plans have been reviewed for coordination with the permit application. See below for additional information: Valuation: Scope of Work: Floor Area: Notes: NIA Confirmed Confirmed Confirmed Our comments follow on the attached list. Please call if you have any questions or if we can be of further assistance. Sincerely, True North Compliance Services Review By: Amer Atassi -Plan Review Engineer True North Compliance Services, Inc. 3939 Atlantic Avenue Suite 224, Long Beach, CA 90807 T / 562. 733.8030 STORM WATER POLLUTION PREVENTION NOTES 1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN IS EMINENT. 2. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY INSPECTOR AFTER EACH RUN-OFF PRODUCING RAINFALL. 3. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 4. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT ( 40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 5. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MIN IMUM AGGREGATE. 6. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED . 7. THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED TO ENSURE COMPLIANCE WITH CITY STORM WATER QUALITY REGULATIONS. OWNER'S CERTIFICATE: I UNDERSTAND AND ACKNOWLEDGE TI-lAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES TO TI-lE MAXIMUM EXTENT PRACTICABLE TO AVOID TI-lE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO AVOID TI-lE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITI-l TI-US CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT TI-lE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL TI-lE CONSTRUCTION WORK IS COMPLETE AND APPROVED BY TI-lE CITY OF CARLSBAD. f'Ct G'&--e--J S AGENT NAME PRINT ~ SIGNATURE DATE E-29 STORM WATER COMPLIANCE FORM TIER 1 CONSTRUCTION SWPPP BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE Erosion Control Sediment Control BMPs Tracking Non-Storm Water Waste Management and Materials BMPs Control BMPs Management BMPs Pollution Control BMPs C: C: C: 0 ..., ..... 0 0 :.;::; C: C: -0 :.;::; :.;::; Ol 0 Cl) -0 Cl) -0 Cl) C: u u C: C: Ol E C: E C: ..... 0 ..... ::, ::, 0 !a ·c .Q-0 0 0 E ~ ,._ ,._ ::;::; ,._ Q) ::E " V, Ol ... ..... ...., 0 C: ' ::, >, Ol C: Cl) ... -~ Cl) ..!: Cl) Cl) V, ·c O" ,._ 0 C: Ol Oc, a. Cl) ·c C: V, C: > L. w -~ 0 Best Management Practice* o:d .£ 0 CD a. ,._ 0 Cl.> 0 ,._ (.!) Cl.> C: :;:; V, ,I:: Cl) ~ Cl.> _. Cl.> 0 _. ..c: C: E Cl) 0 C: u ... u en 0 -0 Q) en ::E C: Cl.> C: (BMP) Description ➔ en u Cl.> en ·o Cl.> en Ol Cl.> Ol CD ·e C: Ol C: -0 en 3: C: C) ::::> ~ _. Cl.> ~ s ~ Cl.> _. 0 0 ,I:: C: -ow -0 >, 0 en C: C: 0 ~ E ::;::; ... u C: C) 0 CD en ·-Ol C) .Q Cl.>-........ u Cl.> Oo Ol Cl.> Cl.> ::E 0 Ol 0 C: Cl.> 0::: E 0 ...., N en i!:l 0 u Cl:.:; Cl.> Cl.> C: ~~ 0 = L. -3:: (I) X Cl.> a. a. e Cl.> 0 Q) LL E .:,,{_ 1 _.::, ..c E ~ = en = ,I:: ,._•-C: 0 ]5 u·c ,._ 0 ·c .:,,{_ Ol _. -0 ..c: C: u ,._ Q) ::, -0 ·-Cl.> ·--u (I)_. 0 (I) ,._ (I) ..... -0 0 ...... _ a. !a ,._...., ..c ... ..c 0 ..... u ·-... ·-0 u 0 0 L... 0 ..., Cl.> Cl.> 0 Cl.> 0 C: 0 0 0 Ol .B 0 0 0 Ej ~ ..... ..c: Cl.> ...., 0 +-' 0 ;=: C: ·-C: Cl.> 0 0 ,._ 0 <n Cl.> ..c: ..c ... ~o 0 ...., L... ...., C: ;:ct 0 Cl.)_ o..., 0 ...., a. 0 oo <..:> 3: WO c7i en u 1L (.!) en> en (/) a. (/)_ (/) 0::: a.o c... >U ::E en ::E (/) C/lU en ::E CASQA Designation ➔ I'-a) ~ -.:t-I'-a) 0 N I") I'-a) ~ N I") -.:t-lO 0) ' ~ I") lO CD ~ ~ -I I I I I I I I I I I I I I I I I I I I I I (.) u u u w w w w w w w w g: g: en en (/) (/) ::E ::E ::E ::E ::E Construction Activity w w w w en (/) en en en en en en z z z z 3: 3: 3: 3: 3: I~ Gradinq/Soil Disturbance ~ ~ ~ Trenchinq/Excavation ~ "f,- 'f. Stockoilinq IV'i Drillina/Borina 11 '" Concrete/Asphalt Sawcutting .... Concrete Flatwork "" Pavinq Conduit/Pipe Installation Stucco/Mortar Work \. Waste Disposal ~ Staqinq/Lay Down Area Equipment Maintenance and Fuel inq Hazardous Substance Use/Storaae Dewaterinq Site Access Across Dirt Other (list): Instructions: 1. Check the box to the left of all applicable construction activity ( first column) expected to occur during construction. 2. Located along the top of the BMP Table is a list of BM P's with it's corresponding California Storm water Quality Association (CASQA) designation number. Choose one or more BMPs you intend to use during construction from the list. Check the box where the chosen activity row intersects with the BMP column. 3. Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project. PROJECT INFORMATION Site Address: \ ") ~ fwlC</\ ~ Ct Assessor's Parcel Number: _;)_~\ 't_-_q~O_D_.,_'-[_S-:_,(P_ Emergency Con~ct: (ll.,. )Cf"i...) Nome:_...c:{JA-r;._ __________ _ 24 Hour Phone: b I'? • '3 \(? ,. S'z D£ Construction Threat to Storm Water Quality (Check Box) ~EDIUM □ LOW Cl) ..., Cl) 0 3:..., C: en Cl.> ::, E 0 Cl.> °E Ol oo N C: 00 I ::E CD I i Cl) ..... Cl) O+' 3: C: Cl.> Cl.> E ...., Cl.> ~ Ol uo C: C: oo U::E a) I i X. )C >-- Page 1 of 1 REV 11/17