HomeMy WebLinkAboutSeaside Heating & Air Conditioning Inc; 2024-08-12; PWM25-3498FACPWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 1 City Attorney Approved 6/5/24 CITY OF CARLSBAD MINOR PUBLIC WORKS CONTRACT FARADAY HEAT PUMP #8 SPLIT SYSTEM REPLACEMENT This contract is made on the ______________ day of _________________________, 2024 (“Contract”), by the City of Carlsbad, California, a municipal corporation (“City”) and Seaside Heating & Air Conditioning, Inc., a California corporation whose principal place of business is 1359 Rocky Point Drive, Oceanside, California 92056 (“Contractor”). City and Contractor agree as follows: DESCRIPTION OF WORK. Contractor shall perform all work specified in the Contract documents for the project described by these Contract Documents (hereinafter called “Project”). PROVISIONS OF LABOR AND MATERIALS. Contractor shall provide all labor, materials, tools, equipment, and personnel to perform the work specified by the Contract Documents unless excepted elsewhere in this Contract. CONTRACT DOCUMENTS. The Contract Documents consist of this Contract, exhibits to this Contract, Contractor's Proposal, the Plans and Specifications, the General Provisions, as contained in the Standard Specifications for Public Works Construction “Greenbook,” latest edition and including all errata; Part 1 General Provisions, addendum(s) to said Plans and Specifications, and all proper amendments and changes made thereto in accordance with this Contract or the Plans and Specifications, all of which are incorporated herein by this reference. When in conflict, this Contract will supersede terms and conditions in the Contractor’s proposal. LABOR. Contractor will employ only skilled workers and abide by all State laws and City of Carlsbad Ordinances governing labor. GUARANTEE. Contractor guarantees all labor and materials furnished and agrees to complete the Project in accordance with directions and subject to inspection approval and acceptance by Brian Bacardi (City Project Manager). PAYMENT. The City shall withhold retention as required by Public Contract Code Section 9203. PREVAILING WAGE RATES. Any construction, alteration, demolition, repair, and maintenance work, including work performed during design and preconstruction such as inspection and land surveying work, cumulatively exceeding $1,000 and performed under this Contract constitute “public works” under California Labor Code Section 1720 et seq., and are subject to state prevailing wage laws. The general prevailing rate of wages, for each craft or type of worker needed to execute the contract, shall be those as determined by the Director of Industrial Relations pursuant to the Sections 1770, 1773 and 1773.1 of the California Labor Code. Consistent with the requirement of Section 1773.2 of the California Labor code, a current copy of applicable wage rates may be obtained via the internet at: www.dir.ca.gov/dlsr/. Contractor shall not pay less than the said specified prevailing rates of wages to all such workers employed by him or her in the execution of the Contract. Contractor and any subcontractors shall comply with Section 1776 of the California Labor Code, which requires keeping accurate payroll records, verifying and Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B August12th PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 2 City Attorney Approved 6/5/24 certifying payroll records, and making them available for inspection. Contractor shall require any subcontractors to comply with Labor Code Section 1776. DIR REGISTRATION. California Labor Code Section 1725.5 requires the Contractor and any subcontractor or subconsultant performing any public work under this Contract to be currently registered with the California Department of Industrial Relations (‘DIR’), as specified in Labor Code Section 1725.5. Labor Code Section 1771.1 provides that a contractor or subcontractor/subconsultant shall not be qualified to engage in the performance of any contract for public work, unless currently registered and qualified to perform public work pursuant to Labor Code section 1725.5. Prior to the performance of public work by any subcontractor or subconsultant under this Contract, Contractor must furnish the City with the subcontractor or subconsultant's current DIR registration number. CALIFORNIA AIR RESOURCES BOARD (CARB) ADVANCED CLEAN FLEETS REGULATION. Contractor’s vehicles with a gross vehicle weight rating greater than 8,500 lbs. and light-duty package delivery vehicles operated in California may be subject to the California Air Resources Board (CARB) Advanced Clean Fleets regulations. Such vehicles may therefore be subject to requirements to reduce emissions of air pollutants. For more information, please visit the CARB Advanced Clean Fleets webpage at https://ww2.arb.ca.gov/our-work/programs/advanced-clean-fleets. CALIFORNIA AIR RESOURCES BOARD (CARB) IN-USE OFF-ROAD DIESEL FUELED FLEETS REGULATION. Contractors are required to comply with the requirements of the In-Use Off-Road Diesel-Fueled Fleet regulations, including, without limitation, compliance with Title 13 of the California Code of Regulations section 2449 et seq. throughout the term of the Project. More information about the requirements and Contractor’s required certification is provided in Exhibit C. CONSTRUCTION MANAGEMENT SOFTWARE. Procore Project Management and Collaboration System. This project may utilize the Owner’s Procore (www.procore.com) online project management and document control platform. The intent of utilizing Procore is to reduce cost and schedule risk, improve quality and safety, and maintain a healthy team dynamic by improving information flow, reducing non- productive activities, reducing rework and decreasing turnaround times. The Contractor is required to create a free web-based Procore user account(s) and utilize web-based training / tutorials (as needed) to become familiar with the system. Unless the Engineer approves otherwise, the Contractor shall process all project documents through Procore because this platform will be used to submit, track, distribute and collaborate on project. If unfamiliar or not otherwise trained with Procore, Contractor and applicable team members shall complete a free training certification course located at http://learn.procore.com/procore-certification-subcontractor. The Contractor is responsible for attaining their own Procore support, as needed, either through the online training or reaching out to the Procore support team. It will be the responsibility of the Contractor to regularly check Procore and review updated documents as they are added. There will be no cost to the Contractor for use of Procore. It is recommended that the Contractor provide mobile access for Windows, iOS located at https://apps.apple.com/us/app/procore-construction-management/id374930542 or Android devices located at https://play.google.com/store/apps/details?id=com.procore.activities with the Procore App installed to at least one on-site individual to provide real-time access to current posted drawings, specifications, RFIs, submittals, schedules, change orders, project documents, as well as any deficient observations or punch list items. Providing mobile access will improve communication, efficiency, and productivity for all parties. The use of Procore for project management does not relieve the contractor of any other requirements as may be specified in the contract documents. Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 3 City Attorney Approved 6/5/24 FALSE CLAIMS. Contractor hereby agrees that any contract claim submitted to the City must be asserted as part of the contract process as set forth in this Contract and not in anticipation of litigation or in conjunction with litigation. Contractor acknowledges that California Government Code sections 12650 et seq., the False Claims Act, provides for civil penalties where a person knowingly submits a false claim to a public entity. These provisions include false claims made with deliberate ignorance of the false information or in reckless disregard of the truth or falsity of the information. The provisions of Carlsbad Municipal Code sections 3.32.025, 3.32.026, 3.32.027 and 3.32.028 pertaining to false claims are incorporated herein by reference. Contractor hereby acknowledges that the filing of a false claim may subject the Contractor to an administrative debarment proceeding wherein the contractor may be prevented from further bidding on public contracts for a period of up to five (5) years and that debarment by another jurisdiction is grounds for the City of Carlsbad to disqualify the Contractor or subcontractor from participating in contract bidding. Signature: ___________________________________ Print Name: __________Charles Balcar______________ REQUIRED INSURANCE. The successful contractor shall provide to the City of Carlsbad, a Certification of Commercial General Liability and Property Damage Insurance and a Certificate of Workers’ Compensation Insurance indicating coverage in a form approved by the California Insurance Commission. The certificates shall indicate coverage during the period of the contract and must be furnished to the City prior to the start of work. The minimum limits of liability insurance are to be placed with California admitted insurers that have a current Best's Key Rating of not less than “A-:VII”; OR with a surplus line insurer on the State of California’s List of Approved Surplus Line Insurers (LASLI) with a rating in the latest Best’s Key Rating Guide of at least “A:X”; OR an alien non-admitted insurer listed by the National Association of Insurance Commissioners (NAIC) latest quarterly listings report. Commercial General Liability Insurance written on an “occurrence” basis, including personal & advertising injury, with limits no less than $2,000,000 per occurrence. If a general aggregate limit applies, either the general aggregate limit shall apply separately to this project/location or the general aggregate limit shall be twice the required occurrence limit. Property damage insurance in an amount of not less than……..$2,000,000 Automobile Liability Insurance in the amount of $2,000,000 combined single limit per accident for bodily injury and property damage. In addition, the auto policy must cover any vehicle used in the performance of the contract, used onsite or offsite, whether owned, non-owned or hired, and whether scheduled or non-scheduled. The automobile insurance certificate must state the coverage is for “any auto” and cannot be limited in any manner. The above policies shall have non-cancellation clauses providing that 30 days written notice shall be given to the City prior to such cancellation. Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 4 City Attorney Approved 6/5/24 The policies shall name the City of Carlsbad as an additional insured. The full limits available to the named insured shall also be available and applicable to the City as an additional insured. WORKERS’ COMPENSATION AND EMPLOYER’S LIABILITY. Workers’ Compensation limits as required by the California Labor Code. Workers’ Compensation will not be required if Contractor has no employees and provides, to City’s satisfaction, a declaration stating this. BUSINESS LICENSE. The Contractor and all subcontractors are required to have and maintain a valid City of Carlsbad Business License for the duration of the contract. INDEMNITY. Contractor agrees to defend (with counsel approved by the City), indemnify, and hold harmless the City and its officers, elected and appointed officials, employees and volunteers from and against all claims, loss, damage, injury and liability of every kind, nature and description, directly or indirectly arising from or in connection with the performance of the Contract or work; or from any failure or alleged failure of Contractor to comply with any applicable law, rules or regulations including those related to safety and health; and from any and all claims, loss, damages, injury and liability, howsoever the same may be caused, resulting directly or indirectly from the nature of the work covered by the Contract, except for loss or damage caused by the sole or active negligence or willful misconduct of the City. The expenses of defense include all costs and expenses including attorneys’ fees for litigation, arbitration, or other dispute resolution method. THIRD PARTY RIGHTS. Nothing in this Agreement should be construed to give any rights or benefits to any party other than the City and Contractor. JURISDICTION AND VENUE. This Agreement shall be interpreted in accordance with the laws of the State of California. The Contractor agrees and hereby stipulates that the proper venue and jurisdiction for resolution of any disputes between the parties arising out of this Contract is San Diego County, California. Start Work: Contractor agrees to start within thirty (30) working days after receipt of Notice to Proceed. Completion: Contractor agrees to complete work within thirty (60) working days after receipt of Notice to Proceed. Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 5 City Attorney Approved 6/5/24 CONTRACTOR’S INFORMATION. Seaside Heating & Air Conditioning, Inc. 1359 Rocky Point Drive (name of Contractor) 790514 (street address) Oceanside, CA 92056 (Contractor’s license number) C-20, C-38, C-4 1/31/2025 (city/state/zip) 760-643-1100 (license class. and exp. date) 1000005586 6/30/2025 (telephone no.) cb@seasidehvac.com (DIR registration number/exp. date) (e-mail address) AUTHORITY. The individuals executing this Contract and the instruments referenced in it on behalf of Contractor each represent and warrant that they have the legal power, right and actual authority to bind Contractor to the terms and conditions of this Contract. [signatures on following page] Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 6 City Attorney Approved 6/5/24 CONTRACTOR SEASIDE HEATING & AIR CONDITIONING, INC., a California corporation CITY OF CARLSBAD, a municipal corporation of the State of California By: By: (sign here) Charles Balcar, President Paz Gomez, Deputy City Manager, Public Works, as authorized by the City Manager (print name, title) By: ATTEST: SHERRY FREISINGER, City Clerk (sign here) Taylor Sebring, Chief Financial Officer By: (print name, title) Deputy City Clerk If required by City, proper notarial acknowledgment of execution by Contractor must be attached. If a corporation, Contract must be signed by one corporate officer from each of the following two groups: Group A Group B Chairman, President, or Vice-President Secretary, Assistant Secretary, CFO or Assistant Treasurer Otherwise, the corporation must attach a resolution certified by the secretary or assistant secretary under corporate seal empowering the officer(s) signing to bind the corporation. APPROVED AS TO FORM: CINDIE K. McMAHON, City Attorney BY: _____________________________ Assistant City Attorney Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 7 City Attorney Approved 6/5/24 EXHIBIT A LISTING OF SUBCONTRACTORS BY GENERAL CONTRACTOR Set forth below is the full name and location of the place of business of each subcontractor whom the Contractor proposes to subcontract portions of the Project in excess of one-half of one percent of the total bid, and the portion of the Project which will be done by each subcontractor for each subcontract. NOTE: The Contractor understands that if it fails to specify a subcontractor for any portion of the Project to be performed under the contract in excess of one-half of one percent of the bid, the contractor shall be deemed to have agreed to perform such portion, and that the Contractor shall not be permitted to sublet or subcontract that portion of the work, except in cases of public emergency or necessity, and then only after a finding, reduced in writing as a public record of the Awarding Authority, setting forth the facts constituting the emergency or necessity in accordance with the provisions of the Subletting and Subcontracting Fair Practices Act (Section 4100 et seq. of the California Public Contract Code). If no subcontractors are to be employed on the project, enter the word “NONE.” SUBCONTRACTORS Type of Work to be Subcontracted Business Name and Address DIR Registration No. & Expiration Date License No., Classification & Expiration Date % of Total Contract Total % Subcontracted: _______________ The Contractor must perform no less than 50% of the work with its own forces. Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B Crane Brewer Crane LLC 12570 Hwy 67, lakeside CA 92404 1033838 12/31/2025 1000054471 12/31/2024 x 3 x 3 xxx 6/30/2025I PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 8 City Attorney Approved 6/5/24 EXHIBIT B Faraday Heat Pump #8 Split System Replacement Contractor to provide all labor, tools, and materials to replace Heat Pump #8 with a new 5-ton Bryant 215S Heat Pump and Carrier FJ4 Fan Coil at the Faraday Building located at 1635 Faraday Avenue, Carlsbad California, 92008. All work and materials to be consistent with the contactor’s proposal dated July 31, 2024, which is incorporated into this document as Exhibit D. Notes: • Contractor to remove and dispose of all replaced equipment. • Contractor to test and verify operation of system. • Contractor shall maintain the worksite in a clean workman like manner. JOB QUOTATION ITEM NO. UNIT QTY DESCRIPTION PRICE 1 LS 1 Faraday Heat Pump #8 Split System Replacement $17,753 TOTAL* $17,753 *Includes taxes, fees, expenses and all other costs. Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 9 City Attorney Approved 6/5/24 EXHIBIT C In-Use Off-Road Diesel-Fueled Fleet Regulation Requirements CARB implemented amendments to the In-Use Off-Road Diesel Fueled Fleets Regulations that apply broadly to all self-propelled off-road diesel vehicles 25 horsepower or greater and other forms of equipment used in California. More information about the requirements can be found at https://ww2.arb.ca.gov/our-work/programs/use-road-diesel-fueled-fleets-regulation Contractors are required to comply with the requirements of the In-Use Off-Road Diesel-Fueled Fleet regulations, including, without limitation, compliance with Title 13 of the California Code of Regulations section 2449 et seq. throughout the term of the Project. The City is a “Public Works Awarding Body,” as that term is defined under Title 13 California Code of Regulations Section 2449(c)(46). Accordingly, the Contractor must submit, with their pre-award contract documents, valid Certificates of Reported Compliance (CRC) for the Contractor’s fleet, and for the fleets of any listed subcontractors (including any applicable leased equipment or vehicles). Failure to provide a valid CRC, will limit the city’s ability to proceed with awarding this Contract. Contractor has an on-going obligation for term of this Agreement to provide copies of Contractor’s, as well as all listed subcontractors, most recent CRC issued by CARB. Throughout the Project, and for three (3) years thereafter, Contractor shall make available for inspection and copying any and all documents or information associated with Contractor’s and subcontractors’ fleet including, without limitation, CRC, fuel/refueling records, maintenance records, emissions records, and any other information the Contractor is required to produce, keep or maintain pursuant to the Regulation upon two (2) calendar days’ notice from the City. Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 10 City Attorney Approved 6/5/24 EXHIBIT C (CONT.) IN-USE OFF-ROAD DIESEL-FUELED FLEET REGULATION CERTIFICATION Contractor hereby acknowledges that they have reviewed the CARB’s policies, rules and regulations and are familiar with the requirements of In-Use Off-Road Diesel-Fueled Fleet Regulation. Contractor hereby certifies, subject to the penalty of perjury, that the option checked below relating to the Contractor’s fleet, and/or that of their subcontractor(s) (“Fleet”) is true and correct: ☐ The Fleet is subject to the requirements of the Regulation, and the appropriate Certificate(s) of Reported Compliance have been attached hereto. ☐ The Fleet is exempt from the Regulation under Section 2449.1(f)(2), and a signed description of the subject vehicles, and reasoning for exemption has been attached hereto. ☐ Contractor and/or their subcontractor is unable to procure R99 or R100 renewable diesel fuel as defined in the Regulation pursuant to Section 2449.1(f)(3).Contractor shall keep detailed records describing the normal refueling methods, their attempts to procure renewable diesel fuel and proof that shows they were not able to procure renewable diesel (i.e., third party correspondence or vendor bids). ☐ The Fleet is exempt from the requirements of the Regulation pursuant to Section 2449(i)(4) because this Project has been deemed an “emergency”, as that term is defined in Section 2449(c)(18). Contractor shall only operate the exempted vehicles in the emergency situation and records of the exempted vehicles must be maintained, pursuant to Section 2449(i)(4). ☐ The Fleet does not fall under the Regulation or are otherwise exempt and a detailed reasoning is attached to this certification. Name of Contractor: Seaside Heating & Air Conditioning, Inc. Signature: Name: Charles Balcar Title: President Date: Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B X 8/9/2024 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 11 EXHIBIT D Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B Seaside Heating & Air Conditioning Inc. 1359 Rocky Point Dr. Oceanside, CA 92056 Phone# Fax# 760-643-1100 760-842-5642 Lie. #790514 City of Carlsbad Facilities 405 Oak Ave Carlsbad, CA 92008 ATTN: Facilities Division Job Location 1635 Faraday Ave Carlsbad, CA 92008 Description Split System heat pump #8 is a 25 year old 5 ton split system has a refrigerant leak in the coil, the unit is not repairable. Proposal to replace the existing 5 ton system with a new 5 ton heat pump condensing unit Bryant M#2 l 5SAN06000A with a matching fan coil. The scope of work includes condenser coil coating, disposal, care, labor paid at prevailing wage and tax PURCHASER'S ACCEPTANCE: I Total By: Date: Proposal Date Proposal # 7/31/2024 61 77 Rep CB Total 17,753.00 $17,753.00 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 12 Materials Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B 215S Legacy™ Line Single-Stage Heat Pump with Puron® Refrigerant 1-1/2 To 5 Tons Product Data Titis unit hos been designed utilizing Bryant's non-ozone depicting Puron® refiigerant. I !eat pwnps with Puron® refrigerant provide a collection of features unmatched by any other family of equipment. NOTE: Ratings contained in tltis document arc subject to change at any time. Always refer to the AHR.I directory (www.ahridircctory.org) for the most up-to-dale ratings infonnation. Efficiency Industry leading Features/ Benefits 14.3 -15.2 SEER2 / I 1.0 -12.5 EER2 /7.5 -8.1 IISPF2 (depending on unit size and indoor combination installed) i\ficrotubc technology refrigeration system Indoor air quality accessories available Sound • Sound levels as low as 69 dBA with accessory sound blanket Comfort • System suppor1s programmable or standard thcnnoslal controls Reliability 'on-ozone depleting Puron® refrigerant Scroll compressor Internal pressure relief valve Internal lhennal overload Loss of charge switch Filler drier Balanced refrigeration system for ma.ximwn reliability Durability D uraGuardTM Prolcction Pad.age: • Solid, durable sheet metal construction • Dense wire coil guard Applications Long-line -up 10 250 feet (76.20 m) total equivalent length, up lo 200 feel (60.96 m) condenser above evaporator, or up to 80 n. (24.38 m) evaporator above condenser (See Longlinc Guide for rnor,:; infonnation.) Low ambient cooling (down lo O"F/-17.8°C) with approved low ambient accessory kits PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 13 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B 215S: Product Data MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7,8,9 10 2 1 5 s A N 018 0 Product Tier& SEER2 OD Design Major Series Voltage Cooling Feature Family Refrigerant Type Capacity 2=HP 1 = Legacy 5 = 14.3 S = Single A-Z=Major N = 208-230-1 or 018 = 18,000 BTUH (1.5 Tons) O= R410A SEER2 Stage Series 2081230.1 024 = 24,000 BTUH (2 Tons) Standard P = 208-230.3 or 030 = 30,000 BTUH (2.5 Tons) 2081230.3 036 = 36,000 BTUH (3 Tons) E = 460.3 042 = 42,000 BTUH (3.5 Tons) 048 = 48,000 BTUH (4 Tons) 060 = 60,000 BTUH (5 Tons) WM-fiii,l•i U.dlhtAHAlc.n.d TMMlrtniclliNa . ..-,.., ,-tk:IIJllllonl'I.,. piqarsnFcr..ilGdon DfOlll'lifiollionlorilllllillidull prvdu:111,!iJOI,;, __,~11111- I @ C US Q.llllty 1509001 •-~ ~ ~ =-- Tested AHRI Combination Ratings NOTE: Ratings contained in this document are subject to change at any time. For AHR! ratings certificates, please refer to the AHR! directory www.alindirectory.org 11 0 Special Feature 0 = Standard Additional ratings and system combinations can be accessed via the Ratings Database here: www.MyBryantRatings.com CATALOG ORDERING NUMBERS Size Model Number 18 215SAN01800A 24 215SAN02400A 30 215SAN03000A 36 215SAN03600A 42 215SAN04200A 48 21 5SAN04800A 60 215SAN06000A Standard Features Feature 18 24 JO 36 42 48 Puron Refrigerant X X X X X X Scroll Compressor X X X X X X Field Installed Filter Drier X X X X X X Front Seating Service Valves X X X X X X Intern al Pressure Relief Valve X X X X X X Intern al Thermal Overload X X X X X X Long Line capability X X X X X X Low Ambient capability with Kit X X X X X X Suction LineAccumulator X X X X X X Loss of Charge Switch X X X X X X X = standard Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 2 12 A Region A= Standard HP 60 X X X X X X X X X X PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 14 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B 215S: Product Data Physical Data Unit Size 18 24 30 36 42 Compressor Type scroll Refrigerant Puron®(R-410A) Contrci TXV (Puron® Hard Shutoff) Charge (lb) 5.9 6.3 9.0 9.0 9.9 Outdoor Htg. Piston# 42 46 52 57 61 Cond Fan Forward Swept or Propeller Type, Direct Drive Air Discharge Vertical Air Uty \._,m,) LJ•□ LOJL LOJL JJJV j /lb Motor HP 1/12 1/10 1/10 1/4 1/4 Motor RPM 800 825 825 825 1110 Cond Coil Face Area (Sq ft) 15.0 17.2 15.0 15.0 17.2 Fins per In. 20 20 20 20 20 Rows 1 1 2 2 2 Circuits 6 6 7 7 10 Valve Connect (In. ID) Vapor 5/8 5/8 3/4 3/4 7/8 Liquid 3/8" tcemgerant Iuoes (In. vu1 Rated Vaport (0-80 Fl Tube Length) 5/8 5/8 3/4 3/4 7/8 Rated Liquid Linet (0-80 Fl Tube Length) 3/8" *. For 1.5 ft. lineset t. Units are rated with 2.5 ft (7.6 m) oflineset length. SeeVapOf Line Sizing and Cooling Capacity Loss table when u:ing other :izes and lengths oflineset. t-See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables. Note: See unit Installation Instruction for proper installation. Vapor Line Sizing and Cooling Capacity Loss 48 60 10.8 13.7 65 76 J , lb . , 1/4 1/4 1110 825 19.3 25.1 20 20 2 2 12 12 7/8 7/8 7/8 1 1/8 Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for HP systems with Puron® refrigerant: Vapor Line Sizing and Cooling Capacity Losses-Puron® Refrigerant 1-Stage Heat Pump Applications Cooling Capacity Loss (%) Acceptable Total Equivalent Line Length (ft) Unit Nominal Size Vapor Line Standard Application Long Line Application Requires Accessortes (Btuh) Diameters (In. OD) 25 50 80 so+ 100 125 150 175 200 225 (7.62) (15.2) (24.4) (24.4+) (30.48) (38.10) (45.72) (53.34) (60.96) (68.58) 1/2 1 2 3 3 4 6 7 8 9 10 18,000 5/8 0 0 1 1 1 1 2 2 3 3 5/8 0 1 1 1 2 3 3 4 4 5 24,000 3/4 0 0 0 0 0 1 1 1 1 1 5/8 1 2 3 3 3 4 5 6 7 8 30,000 3/4 0 0 1 1 1 1 2 2 2 3 7/8 0 0 0 0 0 1 1 1 1 1 5/8 1 2 4 4 5 6 7 9 10 11 36,000 3/4 0 0 1 1 1 2 2 3 3 4 7/8 0 0 0 0 0 1 1 1 1 2 3/4 0 1 2 2 2 3 4 4 5 6 42,000 7/8 0 0 1 1 1 1 2 2 2 3 3/4 0 1 2 2 3 4 5 5 6 7 48,000 7/8 0 0 1 1 1 2 2 2 3 3 3/4 1 2 4 4 5 6 7 9 10 11 60,000 7/8 0 1 2 2 2 3 4 4 5 5 1 1/8 0 0 0 0 1 1 1 1 1 1 standard Length= 80 ft. (24.4 m) or less total equivalent length Applications in this area are long line. Accessories are re(J.lired as shown recommended on Long line Application Guidelines Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3 250 (76.20) 12 3 6 2 9 3 1 13 4 2 6 3 8 4 12 6 2 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 15 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B 215S: Product Data Refrigerant Piping Length Limitations Maximum Line Lengths: The maximum allowable total equivalent length for heat pumps varies depending on the vertical separation. See the tables below for allowable lengths depending on whether the outdoor unit is on the same level, above or below the outdoor unit. Maximum Line Lengths for Heat Pump Applications MAXIMUM ACTUAL LENGTH MAXIMUM EQUIVALENT LENGTH{ MAXIMUM VERTICAL SEPARATION n(m) n(m) rt(m) Units on equal level 200 (61) 250 (76.2) N/A Outdoor unit ABOVE 200 (61) 250 (76.2) 200 (61) indoor unit Outdoor unit BELOW See Table 'Maximum Total Equivalent l ength: Outdoor Unit BELOW Indoor Unit' indoor unit *.* Maximwn actual length not to exceed200 ft (61 m) Maximum Total Equivalent Length• { -Outdoor Unit BELOW Indoor Unit Liquid Line HP with t'UIOTT® Refrigerant - Maximum Total Equivalent Length Size Diameter Vertical Separation n (m) Outdoor unit BELOW Indoor unit; w/ TXV 0-20 21-30 31-40 41-50 51-60 61-70 71-80 (0 • 6.1) (6.4 • 9.1) (9.4 • 12.2) (12.5 • 15.2) (15.5 • 18.3) (18.6-21.3) (21.6 • 24.4) 18,000 318 250' 250' 250' 24,000 3/8 250' 250' 250' 30,000 3/8 250' 250' 250' 36,000 3/8 250' 250' 250' 42,000 3/8 250' 250' 250' 48,000 3/8 250' 250' 250' 60,000 3/8 250' 225' 190 *.Total equivalent length accounts for losses due to elbows or fitting. See the Loog Line Guideline for details. -= outside acceptable range Long Line Applications 250' 250' 250' 250' 250' 250' 250' 250' 250' 250' 250' 250' 250' 250' 250' 250' 250' 250' 250' 150 250' 230 160 - 150 110 -- An application is considered Long Line when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. Defining a system as long line depends on the liquid line diameter, actual length of the 1ubing, and vertical separation between the indoor and outdoor units. For Heat Pump systems, the chart below shows when an application is considered Long Line. Beyond these lengths, long line accessories are required: Liquid Line Size 3/8 Note: See Long Line Guideline for details HP with Puron® Refrigerant Long Line Description ft (m) Beyond these lengths, long line accessories are required Units On Same Level Outdoor Below Indoor BO (24.4) 20 (6.1) vertical or 80 (24.4) Iota! Outdoor Above Indoor 80 (24.4) Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 4 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 16 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B 215S: Product Data Accessories KIT NUMBER KMCH1701AAA KMCH1601AAA KMTD0101TDR KHAIR0201AAA KHALS0401 L LS KHASS0606M PK KSACY0101AAA KSAFT0101 AAA KSAHl0401 PUR KSAHS2501AAA KSALA030141 0 KSALA1001AAA KSATX0201 PUR KSATX0301 PUR KSATX0401 PUR KSBTX0201 PUR KSBTX0301PUR KSBTX0401PUR KSASH2301COP KSASH2401COP KSASF0201AAA X =Accessory S= Standard KIT NAME 18 24 30 36 42 48 Crankcase Healer X X X X Crankcase Heater X X Time Delay Relay X X X X X X lsolalion Relay X X X X X X Solenoid Valve Kil X X X X X X Snow Sland X X X X X X Cycle Protector X X X X X X Evaporator Freeze stat X X X X X X High Pressure Switch Kit X X X X X X Hard start X X X X X X Low Ambient Cooling Pressure Switch X X X X X X MotorMaster X X X X X X TXVKil X X X TXVKil X X TXVKil X TXVKit X X X TXVKil X X TXVKil X Sound Blanket X X X X Sound Blanket X X Support Feet X X X X X X Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 5 60 s X X X X X X X X X X X X X X PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 17 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B 215S: Product Data Accessory Usage Guideline REQUIRED FOR LOW-AMBIENT REQUIRED FOR REQUIRED FOR Accessory COOLING APPLICATIONS LONG LINE APPLICATIONS SEA COAST APPLICATIONS (Below 55'F / 12.B'C) (Within 2 miles/ 3.22 km) Accumulator Standard Standard Standard Ball Bearing Fan Motor Standard Standard Standard Compressor start Assist Capacitor and Yes Yes No Relay Crankcase Heater Yest Yew No Evaporator Freeze Thennostat Yes No No Hard Shutoff TXV Yes Yes No Isolation Relay Yes No No Liquid Line Solenoid Valve No See Long-Line Application Guideline No Motor Master® Control or Yes No No Low Ambient Switch Support Feet Recommended No Recommended *. For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 fl. (6.09 m) vertical differential, refer to Residential Split-System Longline Application Guideline. t. Standard on 3 phase units only Accessory Description and Usage (Listed Alphabetically) 1. Ball-Bearing Fan Motor A fan motor with ball bearings which pennits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when MotorMaster® is used. 2. Compressor Start Assist -Capacitor and Relay Start capacitor and relay gives a ''hard" boost to compressor motor at each start up. Usage Guideline: Required for single-phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 3. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance ofliquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 4. Cycle Protector The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling. 5. Evaporator Freeze Thermostat An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Usage Guideline: Required when low ambient kit has been added. 6. Low-Am hient Pressure Switch Kit A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low-ambient temperatures down to 0°F (-l 8°C) when properly installed and also using wind baffles. Instructions provided in accessory kit. Usage Guideline: A Low-Ambient Pressure Switch or MotorMaster® Low-Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55°F (12.8°C). 7. MotorMaster'" Low-Ambient Controller A fan-speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to 0°F/-l 7.8°C), it maintains condensing temperature at I 00'F ±10°F (37.8°C ±5.5°C). Usage Guideline: A MotorMaster® Low Ambient Controller or Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55°F (12.8°C). Suggested for all commercial applications. 8. Outdoor Air Temperature Sensor This device enables the thermostat to display the outdoor temperature. This device is also required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for use with compatible Bryant thermostats. 9. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level of the compressor. Usage Guideline: Suggested when unit is installed closer than 15 ft ( 4.57 m) to quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft (3 m) apart. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 6 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 18 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B 215S: Product Data Accessory Description and Usage (Listed Alphabetically) Continued 10. Support Feet Four or five stick-on plastic feet that raise the unit 4 in. (101.6 mm) above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion. Usage Guideline: Suggested in the following applications: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound ratings. 11. Thermostatic Expansion Valve (TXV) A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available. Usage Guideline: Required to achieve AHR! ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications. Required for use on all zoning systems. 12. Time-Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to AHR! Directory of Certified Product Performance (AHR! Directory). When a Time-Delay Relay (TDR) is called for in the AHR! Directory, use a 30 second TDR for MicroChannel Indoor units and use a 90 second TDR for Round Tube Plate Fin Indoor units. 13. Winter Start Control This control is designed to alleviate nuisance opening of the low-pressure switch by bypassing it for the first 3 minutes of operation. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 7 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 19 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B 215S: Product Data Electrical Data OPERVOLTS UNIT SIZE V/PH MAX MIN 18 24 30 36 208-230-1 253 197 42 48 60 *. Perrmissible limits of the voltage range at which the unit will operate satisfactorily t. Time•Delay fuse. FLA-Full Load Amps LRA-Locked Rotor Amps MCA-Minimum Circuit Amps RLA-Rated LoadAmps COMPR LRA RLA 45.7 10.3 59.5 11.1 67.9 14.1 83.1 15.3 110.0 18.6 120.0 25.0 150.0 25.6 NOTE: Control circuit is 24· Von all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with requirements ofASHRAE Standards 90.1 Short Circuit Current Rating (SCCR): 5kA nns Sound Power Level Without Sound Hood FAN FLA MCA 0.50 13.4 0.60 14.5 0.60 18.2 1.20 20.3 1.40 24.7 1.52 32.8 1.20 33.2 STANDARD TYPICAL OCTAVE BAND SPECTRUM (dB, without tone adjustment) UNIT SIZE RATING 125 250 500 1000 2000 4000 (dBA) 18 71 70.2 66.4 65.1 67.4 62.8 58.2 24 76 66.3 68.4 69.4 67.7 64.4 61.4 30 76 70.1 71.3 70.8 69.6 64.0 60.6 36 76 74.0 72.5 71 .7 70.5 66.1 61.7 42 76 72.1 72.6 70.0 67.6 62.9 60.5 48 76 75.5 72.4 71.4 68.3 63.1 60.5 60 76 65.2 67.0 67.4 70.0 62.6 59.7 NOTE: Tested in compliance with AHRI 270 but not listed with AHRI. Sound Power Level With Sound Hood STANDARD TYPICAL OCTAVE BAND SPECTRUM (dB, without tone adjustment) UNIT SIZE RATING 125 250 500 1000 2000 4000 (dBA) 18 69 70.6 66.2 64.8 65.7 61 .2 57.5 24 74 66.7 68.1 68.7 66.5 63.1 60.0 30 74 71.4 70.5 70.5 68.3 63.4 60.3 36 74 74.7 72.7 71.8 68.6 64.3 59.0 42 74 72.8 73.7 70.3 67.3 62.6 5~.8 48 74 76.3 71.9 710 68.1 62.9 60.0 60 73 65.4 67.5 67.5 68.8 61.5 58.5 NOTE: Tested in compliance with AHRl 270 but not listed with AHRI. Charging Subcooling (TXV-Type Expansion Device) UNIT SIZE-VOLTAGE REQUIRED SUBCOOLING "F ("C) 18 7 (3.9) 24 7 (3.9) 30 12 (6.7) 36 12 (6.7) 42 10 (5.6) 48 13 (7.2) 60 10 (5.6) HP Only Replacement with Piston Indoors This heat pump may only be installed with piston metered indoor units as replacement components in a piston system MAXFUSE or CKTBRK AMPS 20 25 30 30 40 50 50 8000 52.5 55.9 54.9 55.6 56.0 55.5 55.5 8000 51.3 53.1 53.5 51.6 53.4 53.9 52.9 When installing a non-rated heat pump with a piston indoor unit, the correct piston must be installed, which should be listed in the indoor unit Installation Instmctions or Product Data. Replacement pistons can be ordered from Replacement Components (RC). Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 8 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 20 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B Dimensions T L~ C(:lnOL &.PPI.' (OM t-'r~·:0 n?J >'.IL( ~JI&':¢~ ~) lCJnl·lt{ COU !J.'• ] n' / ~---'~"L·•:_:!!L;_, -~Li ', = ,' .;ciHOiL11,cc11lj ----Y~----1 1------x,,------< •·1.11.,.,c,,o..._:,o,,., 1·0.ot',.O.>tM"; ~~JJ_y,..,..,~ .... ,., ........ _, __ .,. ... ,y, I 1 n111· Ill.)) H J ,,,-G-('l n NOTE: ALL DIMENSIONS IN INCH (MM) F-- ,OTES 1, ~ OF GRAVITY ;,,.. 0 )1!':0!.~\ I/Eton ~IOCIOIIS n:? i,,:.-~ U.S. ECCN: Not Subject to Regulation (N.S.R.) PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 21 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B Clearances 24" (609.6) Service 18" (457.2) Wall 6" (152.4 mm) 12" (304.8) 24" (609.6) Service Note: Numbers In () = mm Allow 48" above unit 12" (304.8) 18" (457.2) Clearances (various examples) Wall 24" (609.6) Service 12" (304.8) 18" (457.2) Wall 24" Service 12" (304.8) 24" (609.6) Service 6" ~ (152.4) ~ IMPORTAJ"'i"T: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re-circulation of discharge air. PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 22 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B ~ Balance Point Worksheet ~ 80 0 f ,( 70 0 c., z ~ 60 ::c C w 50 ~ c., ::c w::, !z Iii 40 ;:: :IE z ::, ui U) 0 .J ~ ::c c., z c .J 5 m 30 20 10 0 . ,~ . -. -10 0 ,_ -,_ ,_ ,- ------- 10 ,- ~ - ~ --------,_ --- , __ , __ --, __ 20 30 40 23.4 215SAN060 .. A~I--FJ4DNXD60L • ,~ 20.5 ,,, -215SAN048"A~~ ~ -i... FJ4DNXC48L" 17.6 --,.15SAN042"0Alj J4DNXC42L" , -7 7 ... -1 -1 14.6 215SAN036"A~r FJ4DNXB36L" . . 215SAN030"A~~ ' -,_ FJ4DNXB30L" 11.7~ -215SAN024"A1 FJ4DNXB24L" 8.8 --, __ 215SAN018""A FJ4DNXA18L" 5.9 2.9 I BASED ON INDOOR ENT. AIR AT 70 °F I~ I AND AT RATED CFM 50 70 0.0 80 OUTDOOR TEMPERATURE, °F PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 23 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B DETAILED COOLING CAPACITIES# 525 600 075 700 780 ... 875 , ... 1125 .,. ,., ... u ~-... 57.u ,1.:>.~ "· "7.0 (19.4 D.:I.U l••• 72.0 (22.2) tu ... ,,.,,..1 0,J.U\ll.~1 til.V\IU,1/ o,. ,•---, (2. :.2) 67.0(19.4) ... u "'· 57. "·' "· 67.u ,l<I."< .... n. tu .... , .. .., "'· , .. o,. ,•-·- fZ.u \LL.~ 01.u(, ....... , 63.0 (17.2)tt 0.£. ,, .... o;l,U l''·"', 62.0(16. :i, ... ,, .... 76.0(23.9) C■p■cltyMBtuh Total Sys. Total Sens; KW"" ,.ou 21.lJ4 11.lU .,u .,1 1;:i,::11 .., 17.18 .,_,., Ll.;>4 11.DU 19.,0 14.5" ,o.u, JO 28.31 14.39 .!:.J.0!1 11.\R:! £1.41 -;t.· .UL =·•· 2tf.f:l 4.W 26.13 18.68 "'·" '°·"' 23.45 .£l:l . .£l Hl.10 26.57 .,..,, ... ,. ..... 3'.r.l ..... '°·'° ,,.,. <O.OU "'·"' ,,.,, 29.00 ,OJU '"·" 29.35 '"··· 22.65 ···" ... .H . ,. .,. .,. ·" .,. .1• ·'" 1.20 ·'" 1.20 1.54 ... .00 .,. .o, ... 1.57 ... .,. .,. ·'" 1.B0 1.,. .., .. , ·" .. , .,, ... 1.93 .. , 1.05 ... 1.05 86.0(29.4} Capaclt'f MBtuh Total Sys. Total sens:i: .. .. , '"·'" 16.41 ... ·" .w Zl.03 ..... "·" "·"° "-41 24.89 22.54 ,,_ .. 25.30 "·" ,,.-"·"" 32.26 '"·'" =·•· ,,_ .. 26.20 '·" ,._,. 13.91 .. , 14AH 18.18 ' .• , ,,.uu HUO '"·'" "· .,, 1.>, . .. ."4 ,.,. 1.34 ,.,. 1.35 . .. .,. ,. .. 1.72 ., . o.,o ,.,. o.,o .,. 1.76 1.7 ,., 1.79 ... . ou ... 2.08 ,.u• ,.uo ,.uo ,.uo ,.,. '·'° 2.13 '·'° 2.15 '·" 2.15 ,.,. CONDENSER ENTERING AIR TEMPERATURES "F ("C) 95.0(36.0) 106.0(40.6) 116.0(Ml.1) 126.0(61.7) Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Svs. Total Sens; l~.llil Hl.H:I 1!U:ltj; 1u.;;,::, ..::u l.J.lU , .... ..... 15.79 15.79 '"·'" 17A2 , .. ,. ,o.,u 25.65 13.40 23.60 17.68 .£1,0{ .£1.01 26.27 21.57 '"·" ,u . , ... 21A4 ... ... .OU . .. .OU 1.50 .OU 1.51 ·"' ·°' 1.93 . .. ... . .. ... . .. 1.97 ·"" ... ... ... 2.00 '·"' ,.u, ,.u, 2.32 ,.,, ,.,, 2.39 , ... 2.30 Total Sens; ... o, , .. , . '"·" "·"' "·" ,,... , .... 24.16 "-"" , .... 22.18 ..... '"··· 20.50 ,._,. 22.50 '"·"° 13.47 12.86 '"·'" 10.41 17.09 '"·" £1.£1 £ ·"'' "1 . .£4 ".£ .".£4 £<1.U 15,78 =·• ,._., ..... , .... .oo ... , .. , .. , .., 1.o, ... . .. ... 1.69 ... 1.70 2.16 ,.,. ,.,u au ,.,u ,.,. 220 ,.,, ,~, 2.22 a, 2.23 ,~, , ... ao 2.59 ,.,. ,.o, ,.,, ,.,, , ... Total Sens,i 14.1U 22.53 , .. ,. 20.63 "·" o.uu , ... .... , • .• u "·" ,,_ .. 12.28 , .... , .. ,. 16.47 "" 15.11 '"·" ,o.ou £0.tJ £1,0£ £,0..J £1,IU 24.77 20.79 2.63 23.06 20.18 .. , ,. .. .... ,. .. ... ... .OU .OU LOU 1.90 ,.., 1.92 2A3 , .. . , .. . , .. . , ... ,Ao 2AB , .• u , ... 2.49 , ... 2.50 , ... '·"' '·"' 2.69 , .. . , .. . , .. . , .. . , .. . , ... 2.93 Total Sens; 1.:..rr 1.:. lt> . .r.:, 11.W l.J.tlll .Hl n.10 '°·" 13.20 13.20 .... 13.95 12.46 20.76 11.66 Hf.ff 14.!t:I 11 . .JO l"l-.£Q ·" .04 1,.,. 18.98 15.82 10.uo , .... 18.0, ...:1.-10 1.£.1:10 ,.. 17.0, ... ,. ·•·= , .... 25.19 14.'9 .£.£.f4 ltl.4,l £U.<IO .QQ Z 1.24 ZL.!4 £. £1.£1 .. ... £..J.IQ £U • .:M: 21.39 19.27 '·" ,.,. .,. ,.14 .,. 2.14 .,. 2.16 .,. ·'" 2.74 ,.,. ,.,, 2.79 ,.01 ,.ou 2.B0 ,.,. 2.01 3.24 .. ,, '·" .. ,, ,.,, '·'" ,.,. 3.27 ::: ___ =":;'·"'::.:==~:··;:;··;;;·~~;··:::'··"":=~=:::''·:··;::=1 a:i.11:1 £.tu 10.l:ftl ..J .• :n 2.96 "'"·"'.. 21.01 3.30 L4.l:f.:, ".£ 1.4/ Z.00 L.l:fO :£1.0 ltl.l:IU .:, . .:,u 25.50 I ,,.,u 2.65 I 24.11 I 24.11 2.95 "·" 22.57 '-'O , ... PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 24 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B DETAILED COOLING CAPACITIES# (Continued) 1060 1200 1350 1240 1400 1575 1390 1600 1800 75.0(23.9) Capac:ltyMBtuh Total Sys. Total Sens; KW" 1.:.. : . .&.J !jf.U(Hf.4) o.>.U\ll.~1 ~,. ,, ... 72.0(22.2) .,. ,., ~-U\''·"JI OL.u\'"·' 57.u \I.:>.~ "· 67.0 (19.4 0,:,.u 11. , .. 1:1, .... , ...... .,_ , .. ., .. ••·- 72.u, ... , or.u(,..,..., 63.0 (17.2)tt t1.: ... ,, .... l) .,. ,, ... , "· 01. ,•---, ti;:I.U [11. 62.0(16.7) bl.U(1;:I, o.,.u 11. "'· ., .. , .. . 72.u, ... , .... , 42.35 '"·°' "'·"' '°· 34.46 ""·"' 39.04 '"·" =·•· "'·"" ·•-~ ..... ., ... 4U.34 ..... 49.37 ..... 41.72 41.UO oo.,. 00.Ul ..... ""·" 41.94 41.04 ... •u. 4 .,.u, ... .. ... 56.98 Df.u ·'"'·"' :n.rt1 63.o -•l "t 49.01 D:l. 4f.:l::t o,. "IO.- f:l. Of.f'd 01. 0.::.0.:l tl-1.U 4tl.f:.! 0.::. (10. 40 . .::i, 57.0 (13.9) 47.99 22.32 ., ... ... ,. 31.77 41.55 41.04 "· 4 , ... 47.99 ,.,. ,.,. 2.38 ,.,. .,. ,.,. .,. ,.,. .,. 2.83 , . 2.80 ,.,u .OU ,.,. .., ,.,. 2.85 ··" ,.,. '·" '·" '·" ,. 3.21 '·" 3.18 '·" ,.,. '·" , ... ,_,. ,. 4 3.24 86.0(2:U) Capaclt-, MBtuh Total Sys. Total sens:i: .>l.tlO .,J, 40.36 21.58 ;:io.,., .:.,.-1, "·" ,,_ .. "·" . ... , ,a.01 .:ll.~ ..J/.:JU 47.01 4:.:.tlU .>.o::.HS 39.75 30.88 '"·" , ... , .,. .. ., ... 4U.,O 40.30 39.64 '"·"" ... ,u 44.12 41.22 ., .. , 54.35 41:1 . .:l/ ,lf.lf 45.92 -.,u ..... ,u 00.UO OU.U, ..... ..... 46.14 46.14 , .. , ... , 2.59 ... , , .. . , .. . 2.65 , .. , 2.67 , ... .... , ... ,.uo ,.u, , ... ,.u, ,.u, 3.10 ,.u, 3.07 ,.u, ,.u, ,.1• ,.,. '·" 3.12 '·" , ... , ... , ... 3.55 , ... 3.51 '·" ,.ou ,.01 , ... '·°' , .. , 3.57 CONDENSER ENTERING AIR TEMPERATURES "F ("C) 96.0(36.0) 106.0(40.6) Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Total Sens; 38.26 20.80 ,._,, 4u.ou ;,1 . .:.1 37.67 29.95 ,, .• , 38.33 38.33 "·"' 4ti.UU ;:,;:,. 4 41.9b 4U.14 . ·" 43.42 --• 44.16 44.18 ... , , .. , ... , 2.84 .... 3.37 '·" '·" , ... , __ ,.., 3.43 , ... , ... , .• 1 , .. , 3.92 , ... 3.99 , ... , ... , ... , ... , ... , ... , ... Total Sens; ... - .al.l" .::ti, 36.01 19.99 .. ... "'·" '"·" :,0.14 ,._,. ~.03 &./,U 35.43 28.96 "'·'" ,._,. .,.,, '"·°' "'·"' 36.38 36.38 ..... 41.J.Hil .l •"'1:1 ..... ,._,, 49.55 27.43 .. ... 40.99 .. ... "IU./;, "1-U,l;I .. ... --= .,.,, . .. ,. 42.00 42.00 ,.,u '·'" ,.,. 3.13 ,. '·" , ... 3.19 ,. , .. . , .. . , .. . , .. . , .. . 3.74 '·" 3.71 ,. ,.,. ,. 3.77 , . ·~· . ... ·~· 4.35 4.0, 4.30 ..,u •. ,u 4.41 .. ,. ·~· .. ,, 4.37 116.0(46.1) Capac:ltyMBtuh Total Sys, Tot,J ,. ., ... 33.63 ... , . ,u. 33.03 34.28 ,,_ .. .,_,, , .. ,, ... ,. ... .. 39.63 Sens,i , .... 19.14 26.12 27.90 "'A• 34.28 ... ., ;:,1,4 '"· ..... 39.63 KW" , ... ,.oo , .• u '·°" 3.50 '·°' , ... , ... 3.54 , ... 3.50 , ... , ... , ... . ... 4.UO 4.UO 4.U• 4.00 4.13 .. 4.10 4.1U ··'" .... .. 4.10 4.16 4.10 . .,. 4.,o .. 4. .. , 4.83 •.• u 4.70 ··" .. ,. .... . ... .... .... 4.05 126.0(61.7) Capacity MBtuh Total Sys. Total Sens; ,,_,, "-" :lb.ti( :lb.Hf ,._., 31.06 18.23 .::tJ.ll .::.l.tJI ,, ... , .... 26.65 ;:,1,;:, H:1.1,1 25.12 ,,_,, .,_ .. "·" . ... , ;:,;.:,4,;,! :l!l.;;!::I .lU.IU .::~.£\/ '"·"' ·•·= 21.47 '"·"' 30.43 26.73 ;;, . .:"' ;;!1.£.o:: .l .Ill' .ll.Uil a.•1 ,._,, ,._,, 31.98 31.98 ;:11.!M .,,.~ . .... ;M.t!ti ::K.tfti ,._., 41.84 24.99 ..... 35.16 30.'4 -10.lU -1!1.lU , .... ,._,. ,._., ,,_,. "·"' 37.02 37.02 '·" , ... ,.,. , ... 3.98 ··" 4.Ul o.u, 4.01 •.u, 4.05 4.UO . ... 4.UO ... , •. ,u .... 4.40 .... 4.56 4.00 4.54 4.04 .... 4.01 .... .... 4.60 4.0U . ... ..,. .... 5.36 "·" 5.31 0.'1 '·" ... , 0.,0 ._,, .. ,. 5.38 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 25 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B DETAILED COOLING CAPACITIES# (Continued) EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES "F ("C) 75.0(23.9) 86.0(2:U) 96.0(36.0) 106.0(40.6) 116.0(46.1) 126.0(61.7) CFM EWB Capac:ltyMBtuh Total Sys. Capaclt-,MBtuh Total Sys. Capai:ltyMBtuh Total Sys. Capac:ltyMBtuh Total Sys. Capac:ltyMBtuh Total Sys. CapacltyMBtuh Total Sys. Tobi Sens; KW" Tot• sens:i: KW" Tot• Sens; KW"" Total Sens; -· To!O Sens,i KW" Total Sens; KW" , .. ... , . ... , ,.,. oo.u, .... .. ,, , .. , , ... .... ou.,o ••. ,u .... !jf.U(Hf.4) .,_,., ""·'° ,. •. ,u .,.,.., ..,, OD , ... "·" .. ,, 1735 o.>.U\ll.~1 ..... ,.,u ... ,. . ... .... . . .... , .... . .. , ,.,u 04.0U 4.20 ..,, 4/.uo ,2, , ... .,_,. "·"' 0.01 .,. .... , ..... , ... .,.ou .. ,, .,.,u .,.,u ··" ....... .... .... "·" ... , 72.0(22.2) 70.52 37.55 4.00 67.19 36.32 4A0 63.64 35.03 4.85 59.83 33.66 5.38 55.71 32.20 5.98 51.29 30.64 6.64 I .,. ... ,, .,.,. '·" "·" .. ,. ,,_ .. .... .. ... .., . OU.JO .,., . , ... 4U. . .. , 2000 ~-U\''·"JI .... 1 ,.,. ..... •. ,, . .. ,. ..... '"·"' 41.0J '·'" ., ... .... '"·"' .... OL.v\'"·' 00.JO ,.,. '"·" .. ,, ... , OU.O, ,., . ··-__ ,, ..... 0.0U I 57.u \I.:>.~ 57.95 ., ... 3.98 55.74 55.74 4.37 4.92 50.75 5.34 ., .. , 5.94 44.ll9 6.60 "· .. ,. "·"" 4M 4.00 , ... o.uo ,, ... ''·" "·" 67.0(19.4 65.05 48.9" 4.07 01.91 4A6 47.34 4.92 55.03 6.44 51.19 44.33 6.03 47.06 42.83 6.70 2250 !j,:,,u tH. 00.40 ..,. "·" .... 4.00 ,,.,. .... , ... 0.Ul 4U.01 ,.,. ... ,•-· ... ., 4.UO .,. .. .... •. ,u .. ... .. ., o.u. ·•·= .... ~, ... ,, ... ~ "'·"' 4.00 ,,_., ,,_., 4.40 4.00 0,.1. ,_., O.UL .,_.., , ... ,! i :; I #Detailed cooling capacities are based on indoor and outdooc unit at the S&me dwalim per AHRI standardll0/240-2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variatim in capacity may occur. Ill :j:Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For Sfflsible capacities at otherthBD 80°F (27°C), dEdutt 835 Btuh (245 kW) J>f!f 1000 CFM (480 US) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh ~ ~!~:=~:~rt!t::::::::;<!!:i~::.: above80°F (27°C). wi :~Aii"~:!:e~=::::n~t:!'we::;~b~~llda~,7n=:a:~:::~=:~~atim is not an acceptable practice. EWB -Entering Wet Bulbl PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 26 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B HEAT PUMP HEATING PERFORMANCE INDOOR AIR OUTDOOR COIL ENTERING AIR TEMPERATURES "F {°C) -3.0(-19.4) 7.0(-13.9) 17.0(-8.3) 27.0(.2.8) 37.0(2.8) 47.0(8.3) fn.0(13.9) 67.0(19.4} Capacity TotalSys. Capacity TotalSys. Capacity Total Sys. Capacity TotalSys. Capacity Total Sys. Capacity TotalSys. Capacity TolllSys. Capacity Total Sys. EDB CFM ~~ Kwt _____!!~ Kwt _____!!B~ KWt ~B~ Kwt ~B~ KWt ~~ KWt _____!!B~ KWt ____!!B~ KWt Total lnteg• Total lnteg• Total lnteg• Total lnteg• Total lnteg• Total lnteg• Total lnteg• Total lnteg• 525 631 5.80 1.06 824 7.57 112 10.33 9.42 1.18 1282 11.39 125 14.99 1364 132 1743 17.43 1.39 19.89 1989 146 2225 22.25 1.53 66.0(18.3) 600 644 592 107 839 771 113 1049 957 118 1298 1153 124 1517 1381 130 1765 1765 137 2005 2005 142 2235 2235 149 675 656 603 1.09 852 783 114 10.64 970 119 1311 11.65 124 1533 1395 129 1784 1764 1.35 2016 2016 140 2239 2239 1.46 525 598 5.50 1.11 794 7.30 117 10.04 9.15 1.24 1260 11.19 131 14.79 1346 138 1718 17.16 1.46 19.51 1951 153 2199 21.99 1.61 70.0(21.1) 600 610 561 112 808 7.42 118 1020 930 1.24 1276 1133 130 1496 1361 136 1740 1740 143 19.80 1980 150 2201 22.Q1 157 675 621 571 113 821 754 118 1034 943 124 1290 1146 130 1511 1375 135 1759 1759 142 1993 1993 147 2216 2216 153 525 566 5.21 1.15 764 7.Q2 1.22 976 8.90 129 1212 10.77 1.36 14.59 1328 145 1693 16.93 1.53 19.52 1952 161 21.74 21.74 1.69 76.0(23.9) 600 577 5.31 116 778 7.15 123 9.91 904 129 1236 10.98 136 14.75 1342 143 1715 17.15 1.50 19.69 1969 157 2185 21.85 1.64 675 588 541 1.18 790 728 124 10.05 918 119 1268 1126 138 1490 1356 142 1733 1733 149 1979 1979 155 2189 2189 161 700 925 8.51 146 11.80 1084 1.51 14.65 1336 1.57 1755 15.59 1.64 20.48 1864 170 2372 23.72 1.76 26.48 2648 181 2922 29.22 1.87 66.0(18.3) 780 937 862 147 1195 1098 151 1504 1371 158 1771 1573 162 2068 1882 168 2386 2386 173 2651 2651 178 2914 2914 183 900 954 8.77 1.49 12.15 1116 1.52 15.24 1390 1.58 1792 15.92 1.62 20.93 1905 167 2393 23.93 1.71 26.50 2650 175 2695 28.95 1.79 700 892 8.20 152 1147 1054 158 14.22 1297 1.64 1733 15.39 172 20.20 1838 178 2345 23.45 1.85 26.22 2622 190 2863 28.63 1.96 70.0(21.1) 780 904 831 154 1162 1068 158 1440 1313 164 1748 1553 171 2040 1856 176 2360 2360 182 2626 2626 187 2888 2888 192 900 921 8.47 1.55 11.81 10.85 1.59 14.66 1337 1.64 1769 1571 1.70 20.65 1879 175 2386 2386 1.79 26.27 2627 183 26.80 28.80 187 700 857 7.88 1.59 11.12 1022 165 13.86 1264 171 1709 15.18 181 19.92 1813 187 2312 23.12 1.95 25.95 2595 200 2841 28.41 2.05 76.0(23.9) 780 869 799 160 1127 1036 165 1403 1279 171 1725 1532 179 2011 1630 185 2332 2332 192 2600 2600 196 2660 2860 201 900 886 8.15 1.62 11.47 10.54 1.67 14.26 1300 172 1745 15.50 1.78 2036 1853 184 2349 23.49 1.88 26.03 2603 193 2848 28.48 1.97 875 10.57 9.72 164 13.85 1273 1.72 17.26 1576 1.79 2123 18.66 1.89 24.67 2245 196 2851 28.51 2.04 32.89 3289 215 3606 38.06 2.26 66.0(18.3) 1055 1065 998 167 1416 1303 174 1766 1610 181 2156 1915 188 2507 2281 194 2901 2901 201 3355 3355 211 3662 3862 220 1125 10.95 10.07 1.68 14.29 13.13 1.75 17.79 1622 181 2168 1926 1.89 25.21 2294 194 2917 2917 2.01 33.76 3376 210 38.73 38.73 2.19 875 10.06 9.27 1.70 13.39 1230 179 16.83 1535 187 2092 18.58 197 24.34 2215 205 2812 28.12 2.14 32.38 3238 225 3746 37.46 2.39 70.0(21.1) 1055 1037 954 173 1372 1261 181 1720 1568 188 2126 1889 197 2473 2250 203 2860 2860 211 3302 3302 220 3812 3812 230 1125 10.47 9.63 1.75 1383 1271 1.82 17.33 1580 189 2139 19.00 1.97 24.86 2262 203 2876 28.76 2.10 33.23 3323 220 38.25 3825 2.29 '" rn '" 1,o "" "' "" 14~ 1.so '"1 "" ,~ :.!1ij4 '" n4 1.» 1" rn "4 '' 76.0(23.9) 1055 987 9.08 180 1324 1217 188 1675 1527 196 2093 18.59 205 2439 2220 212 2820 2820 220 3250 3250 230 3759 3759 2.41 1125 996 918 181 1335 1227 189 1687 1538 197 2105 1870 208 2452 2231 212 2836 2836 220 3270 3270 230 3775 3775 239 1060 13.57 1248 218 17.01 1563 2.19 21.01 1916 2.26 2584 22.95 2.39 30.04 2734 249 3458 34.56 2.60 39.39 3939 269 4472 44.72 2.76 66.0(18.3) 1200 1382 1271 220 1730 1590 220 2135 1947 227 2614 2322 238 3041 2767 248 3506 3506 258 3998 3998 267 4547 4547 274 1350 14.06 12.93 2.23 1757 1614 2.22 21.65 1974 228 2643 23.48 2.39 30.76 2799 248 3549 35.49 2.57 40.51 4051 265 46.11 4611 2.71 1061) 12.97 1193 228 16.42 1509 2.29 20.40 1860 2.35 2537 22.54 2.48 29.53 2687 259 3400 34.00 2.69 38.63 3863 279 4393 43.93 2.89 70.0(21.1) 1200 13.24 1218 231 1672 1536 231 2074 1691 237 2571 22.64 248 29.91 2722 258 3447 34.47 268 3926 3926 276 4465 4465 285 1350 1347 1239 234 1699 1561 233 2106 1920 239 2601 2310 249 3027 2755 256 3490 3490 287 3981 3981 275 4529 4529 282 1061) 12.31 1132 2.36 15.76 14.46 2.37 19.74 1600 244 2424 21.53 2.55 29.02 2641 268 3342 33.42 279 37.92 3792 290 4317 43.17 3.01 76.0(23.9) 1200 12.56 1155 239 1605 1475 239 2006 1831 2.45 2477 22.00 256 29.40 2675 267 3388 3388 278 3868 3868 288 4386 4388 2.96 1350 1281 1178 243 1634 1501 242 2040 1860 247 2551 2266 259 2974 2706 266 3430 3430 277 3906 3906 286 4447 4447 293 1240 16.99 1563 2.54 21.52 19.77 2.66 28.46 2415 2.78 3194 28.37 2.92 36.96 3365 305 4260 42.80 3.19 48.96 4696 338 5533 55.33 3.53 66.0(18.3) 1400 1730 1591 257 2165 2008 268 2693 2456 279 3229 28.68 292 37.43 3406 303 4309 43.09 316 4958 4958 332 5568 5568 347 1575 1760 1619 281 2218 2038 270 2739 2498 281 3263 2899 292 3782 3442 303 4357 4357 315 5005 5005 329 5608 5608 343 1240 16.32 15.01 2.64 2066 1917 2.76 25.60 2353 2.89 3150 27.98 3.05 36.49 3321 317 4200 42.00 3.33 48.21 4621 352 54.61 54.61 3.66 70.0(21.1) 1400 16.61 1528 267 2121 1949 278 2619 2388 2.90 3184 28.28 304 36.90 3358 316 4266 42.66 330 4864 4884 346 5506 5506 361 1575 1691 1555 270 2153 1978 280 2656 2422 291 3219 2859 305 3729 3393 315 4296 4296 328 4937 4937 342 5539 5539 357 1240 1556 1433 2.73 20.17 18.53 2.68 25.12 2291 300 3106 27.59 3.16 3599 3275 331 4141 41.41 3.47 47.45 4745 367 5391 53.91 3.63 76.0(23.9) 1400 15.88 1460 276 20.52 1885 288 25.50 2325 301 3140 27.89 3.17 36.38 3311 329 4189 41.89 3.43 48.08 4808 361 5436 54.36 3.76 1575 1617 1487 280 2084 1915 291 2586 2358 302 3174 2819 317 3663 3333 328 4235 4235 342 4884 4864 357 5467 5467 372 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 27 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B HEAT PUMP HEATING PERFORMANCE (Continued) INDOOR AIR OUTDOOR COIL ENTERING AIR TEMPERATURES 'F {°C) -3.0(-19.4) 7.0(-13.9) 17.0(-8.3) 27.0(.2.8) 37.0(2.8) 47.0(8.3) fn.0(13.9) 67.0(19.4} Capacity TotalSya. Capacity TotalSys. Capacity Total Sys. Capacity TotalSya. Capacity Total Sys. Capacity TotalSys. Capacity Total Sys. Capacity Total Sys. EDB CFM ~~ Kwt ~~ Kwt __!B.!:!.!!._ KWt ~B.!!:!!!._ Kwt ~B.!!:!!!._ KWt ~~ Kwt __!B~ KWt _!:!_B~ KWt Tot• lnteg• Tot• lnteg• Tot• lnteg• Tot• lnteg• Tot,I lnteg• Total lnteg• Tot• lnteg• Total lnteg• 1390 19.57 1800 2.85 24.39 22.41 2.96 29.74 2712 3.Q7 3556 31.59 3.20 41.01 3732 331 4717 47.17 3.45 54.37 5437 363 6201 6201 3.78 65.0(18.3) 1600 19.94 1834 24.80 2279 30.31 2764 3598 31.96 41.51 3778 4781 47.61 3.41 55.1S 5519 6247 62.47 1800 2025 1862 291 2515 2311 300 3102 2829 311 3632 3226 320 4192 3815 328 4832 4832 339 5575 5575 351 6268 6268 363 1390 18.83 17.32 2.96 23.72 2179 3.08 29.00 2644 319 3511 31.19 3.35 40.48 3684 346 4650 46.50 3.61 53.55 5355 379 61.23 6123 3.95 70.0(21.1) 1600 19.20 1766 24.11 2215 29.46 2686 3551 31.54 3.34 40.96 3727 4713 47.13 54.36 5436 6168 61.68 1800 1951 1794 2445 2247 2987 2724 3587 3186 334 4137 3765 4763 4763 354 5497 5497 6195 6195 1390 1807 1662 308 2300 2113 320 2829 2580 333 3468 3081 3998 3638 382 4584 4584 377 5273 5273 396 6036 6036 412 75.0(23.9) 1600 18.43 1695 3.11 23.40 2150 3.22 2875 2622 334 3507 31.15 3.49 40.45 3681 359 4645 46.45 3.12 53.53 5353 389 6089 60.89 4.02 1800 1874 1723 314 2374 2181 325 2913 2656 3543 3147 349 4085 3717 4695 4695 5415 5415 384 6118 6118 1735 24.41 2245 3.46 30.46 2799 3.55 36.84 3359 366 4394 39.03 3.80 51.13 4653 397 5777 57.77 4.12 65.36 6536 431 7343 7343 4.46 65.0(18.3) 2000 24.94 22.94 3.51 31.05 28.53 3.59 37.49 3418 3.68 4549 40.41 3.84 51.76 4712 395 5957 58.57 4.09 66.39 6639 425 7412 74.12 4.37 2250 2538 2334 357 3153 2897 363 3804 3469 372 4599 4085 386 5240 4769 5921 5921 6722 6722 422 7460 7460 432 1735 2325 2138 359 2939 2700 3.68 3580 3284 380 4269 3792 3.95 5048 4594 414 5700 5700 431 8436 6436 450 7244 7244 466 70.0(21.1) 2000 23.77 21.86 3.84 29.96 2753 3.72 36.45 3324 3.83 4352 38.66 3.96 51.26 4665 413 5774 57.74 4.26 65.36 6536 444 73.17 73.17 4.56 2250 2421 2227 3044 2797 3698 3372 4415 3922 5161 4697 413 5836 5836 425 6617 6617 440 7365 7365 451 1735 2205 2028 372 2828 2598 382 3475 3189 395 4182 3897 411 4979 4531 433 5623 5823 450 '" 75.0(23.9) 2000 22.56 2075 3.77 28.85 26.51 3.86 35.38 3226 398 4237 37.64 4.11 50.41 4587 431 5698 56.98 4.45 64.35 6435 463 7218 72.18 4.76 2250 22.99 2114 29.32 2694 35.92 3275 401 4296 38.16 50.91 4633 431 5748 57.48 4.44 65.12 6512 460 7265 72.65 4.70 NOTE: When the required data falls between the puW.shed data,intetpolation may be performed Extrapolatioo. is oot an acceptable praetice. * The Btuh heating capacity values shown are net integrated values from which the de1i'ost effect has been wbtracted The Btuh heating from supplement beaters should be added to those values to obtain total sys. capacity. t The kW values include the compressor, outdoor fan motoc, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total Sys. kilowatts. EDB-EnteringDryBulb2 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 28 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B 215S: Product Data Guide Specifications General System Description Outdoor-mounted, air-cooled, split-system heat pump unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air-cooled coil, propeller-type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit. Quality Assurance -Unit will be rated in accordance with the latest edition of AHR! Standard 210/240. -Unit will be certified for capacity and efficiency, and listed in the latest AHR! directory. -Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. -Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have C-UL approval. -Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500-hr salt spray test. -Air-cooled condenser coils are pressure tested and the outdoor unit is leak tested. -Unit constructed in ISC9001 approved facility. Delivery, Storage, and Handling Unit will be shipped as single package only and is stored and handled per unit manufacturer's recommendations. Warranty (for inclusion by specifying engineer) U.S. and Canada only. PRODUCTS Equipment Factory assembled, single piece, air-cooled heat pump unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Puron®, and special features required prior to field start-up. Unit Cabinet Unit cabinet will be constructed of galvanized steel and coated with pre-paint. Available with dense grille only Fans Condenser fan will be direct-drive propeller type, discharging air upward. Condenser fan motors will be totally enclosed, I-phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. Fan blades will be statically and dynaruically balanced. Condenser fan openings will be equipped with steel wire safety guards. Compressor Compressor will be hermetically sealed. Compressor will be mounted on rubber vibration isolators. Condenser Coil Condenser coil will be air cooled. Coil will be constructed of aluminum fins mechanically bonded to copper or aluminum tubes which are then cleaned, dehydrated, and sealed. Air-Cooled, Split-System Heat Pump 215S 1-1/2 to 5 nominal tons Refrigeration Components Refrigeration circuit components will include liquid-line shutoff valve with sweat connections, vapor-line shutoff valve with sweat connections, system charge of Puron® refrigerant, POE compressor oil, accumulator, and reversing valve. Operating Characteristics The capacity of the unit will meet or exceed __ Btuh at a suction temperature of __ °F/'C. The power consumption at full load will not exceed kW. Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of __ Btuh or greater at conditions of __ CFM entering air temperature at the evaporator at __ °F wet bulb and __ °F/°C dry bulb, and air entering the unit at °Fi°C. The system will have a SEER of __ Btuh/watt or greater at DOE conditions. Electrical Requirements Nominal unit electrical characteristics will be __ v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of __ v to __ v. Unit electrical power will be single point connection. Control circuit will be 24v. Special Features Refer to section of this Ii terature identifying accessories and descriptions for specific features and available enhancements. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 17 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 29 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B FJ4 Base Series Fan Coil Sizes 18 -60 Turn to the experts Product Data ' I - AIR HANDLER TECHNOLOGY AT ITS FINEST AI0082 The FJ4 fan coil has the proven technology of Carrier fan coil units with Puron® refrigerant. as well as vertical and horizontal applications. The design features contmu·ed condensate pans with n1gged drain connections, ensuring that little waler is Jeft in the lmit at the end of the cooling duty cycle. The lack of standing condensate and corrosion free pans improves IAQ and product life, features homeO\mers appreciate. Standard features include grooved tubing and louvered fins. Coil cin.:uiling has also been updated to make the most of all Carrier heal pumps and air conditioners. Units come with solid state fan controls, I-inch (25111111) thick insulation \\ith R-value of 4.2, multi-speed motors, and fully-wettable coils. Units can accommodate factory-and/or ticld-insta1led heaters from 3 to 30 kW. Assembled at the factory compliant with low leak requirements of less than 2% cabinet leakage rate at 0.5 inches WC. and 1.4% cabinet leakage rate at 0.5 inches W.C. when tested in accordance ,vith ASHRAE I 93 standard. The F.14 fan coil design is loaded \\ith popular features. 'lhesc fan coils utilize the latest in electronic commutation motor (ECM) technology through the use of high efficiency, multi-lap ECM motors allowing reliable air dcl ivcry "~th increased static pressure. It comes in a pre-painted (taupe meta1lic) galvani7.ed steel casing and a factory-supplied power plug for ease of ins1allalion. The unit is shipped with a Puron refrigerant TXV (sizes 18--{i0). STANDARD FEATURES Multi-tap ECM (electronic conunutaling motor) motors-all sizes Integrated motor controls, wiU1 90-sec off TDR fllllclion, have replaced integrated circuit board Five available speed tags lo meet.a wide rnnge of applications Large, grooved tube, louvered fin coils E1liciem, quiet, time-tested blower housings and diffusers Sturdy, drninable condensate pans Cabinet constmction features innovations designed to prevent cabinet sweating. Tested for condensate disposal in much tougher conditions than Air Conditioning and Refrigeration Institute requirements. Super-thick R-4.2 insulation with vapor barrier Pre-painted galvanized steel cabinet (taupe metallic) Design meets stringent regulations for cabinet air leakage of less than 2% when tested al 0.5 inches W.C., and cabinet air leakage less U1an I .4% at 0.5 inches W.C. when tested in accordance \\ilh ASHRAE 193 standard. lnsta11ation-0exible, multipoise units 2-piccc modular design available for 42 thru 60 sizes. Facilitates attic imd crawlspace installations. Horizontal hanging provisions on cabinet No tools required to access tilter. Newly improved filter rack area filter door insulation added for improved air seal. Factory-installed heater packages available on select models (5 through 15 kW). 3 through 30 kW accessory heaters -field installed Factory-supplied power plug Easy plug-in provisions for heater installation. Entty options for high and low voltage wiring hook-up Leak-preventing sweat connections Thcnnostatic expansion valve, TXV, on an coils Designed for manufactured housing applications. PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 30 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B FJ4: Product Data MODEL NUMBER NOMENCLAl\JRE Product F-FanCoil Type/Tier J-Comfort"" Refrigerant Type 4-Puron® Major Series D Electri:al N -2081230V, 1 ph, 60 Hz l F 2 J 3 4 Cabinet Type /Metering Device B -Modular, TXV X -Singular, TXV Cabinet Width A-14";B -17'' C -21";D -24" A.'91 CElmFIED-• ---- Use of 1heAHRICenified TM Mark ind~les a manufaclurer's par1icipa10n in 1he program Fo, verific:a10n ofoer1ifica1ion for indi'VidlEII produ-cts,goti www.ahridirecbry.org. 4 D 5 N 6 X I 110 llllD1 -- C 8 3 9 6 10 ll 12 L 0 0 Electric Heater Size 00 -No Heat 05 -5kW 08 -8kW 10-l0kW 11-llkW 15-15kW Coil Type L-Aluminum Nominal Capacity 18-18,000 24 -24,000 30 -30,000 36 -36,000 42-42,000 48 -48,000 60 -60,000 ~ Armor Tech· Marufactl.l"er-reserves the rigtt to charge, at any tirre, specifications and designs v.ithout nctice and v.itho'1 obligations. 2 .A.200B5 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 31 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B DIMENSIONS ~ LOWER.CONTROL. 3ELECTRICHEATER ACCESS PAm FRONT VIEW LJmM'rn~"t;F~~LJEM~i~.c~~~mmoNS ELECTRICAL CHARACTmms X H 11118' 14 5116' 12 JIU" 12 5116' 10 1118' 18 118' 18 518" 12" X FJ4DWBU& 1.mmllUIGNATIONISTHE14THPOSlTION OFUNITPRODUCTNUNBER 2. ALL OINENSIO~S ARE IN "UCHES" UNLESS NOTED UNIT CONNECTION SIZES SLOPE COIL DETAILS C0NNECTJ0M LOCHIONS SHOWN roRUPFLOIORHORIL LEFTAPPLICUIONS sa 7/H' 21 He· ,s 114• u 11e" u 112• 21114• a 1s1a• 2s s11&" X=lES O=NO •:lES,DUETOAVAILA!ILEFIELD lNSHLLrn HEAHRS. tlOTE:ALLml21"FRONFRONT FOR HRVICE 1 114'~ 1---,~P~~m.______j RIGHT SIDE VIEW ~ Fig.1-FJ4-English(sheet 1) SHIPPING WT ILBSl 120 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 32 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B DIMENSIONS (cont.) NOTES 1 CONDENSAH PAN DRAIN CAPS HOT SHOWN FOR CLAR!TY. 2. ALL DIME~SJONS ARE IN ·rncHES' UNLESS NOTED. ~-~□ HP,t 118" m., HORIZ. LEFT IAS SHIPPED! -~□ ,,,. HP• 1(8' HP• HORIZ. LEFT IAS SHIPPED) SI OPE COIi ri 1/16'11P. AlRFLOW (2PLACESJ• t r====l}-'- AIRFLOW I DOWN FLOW [ w•;I -i ' IL~_J_~--1f"i=~~~---' ''m•: L,t· UPFLOW (AS SHIPPED! (FIELD CONVERTED) HORIZ. RIGHT I FIELD CONVERTED I UP FLOW CAS SHIPPED! A..:..C.filL Fig. 2-FJ4-Engllm (meet 2) PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 33 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B DIMENSIONS (cont.) FRONT VIEW LO"ll[R. COIIUOL, tELICTRlCHEAfER ACCESSPANH SHOWN WITH "A' COIL DElAILS CO~NECTION LOCATIONS FOR UPFLOWOR HORIZ. APPLICAHONS INT FJ40N~C42 SER[ES u ELECTRICAL CHARACTERSTICS 1.SERlESDESIGNATl0NlSTHE14THPOSITlOM OF UNll PRODUCT NUMBER 2. ALL DIMENSIONS ARE lN 'Mlil' UNLESS NOlED. UNIT CONNECTION SIZES SUCfIOM 0181HRU 024 -15 88 I 0. SIIEAT 030 &03S -HI 05 1.D. 511UT 042 lHRU UQ -22.23 LO. SWEAT ~~~~~~Afi:~31 U· F~~EAT mu 536.6 m.o 485.a ~=YES O=~O •:YES, DUE TO AV~lLABLE FIELD INSHLLED HHH~S NOTE; ALL0\11 Sl3 4 FRC4ol FRONT FOR SERVICE 39U m.3 587.4 \ OPllO!IAL FIELD CON~ERTED RHiHT SUE RETURNOPEMUG !SL0PEC0[LUNI1S0NLTJ --------- ---- - SHIPm61/T ({g,I 15.4 r H fOR ~--+~---------------~+·-·_·1·· 31 8 ---l ~ om~~G ~ SLOPE COIL DETAILS COMNECTIONLOCATIONSSHOWN FORUPFLOWORHOR[Z. LEFT APPLICATIONS Fig. 3-FJ4 -Metric (sheet 1) RIGHT SIDE VIEW ~ PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 34 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B DIMENSIONS (cont.) NOTES 1 . CONDENSAlE PAN ORA IN CAPS NOT SHOWN FOR CLARITY. 2.ALLOIMENSIONSARE!N"MM"UNLESSIIOfED. -~q 12.1 m., 22.2 HP.t HORIZ. LEFT IAS SHIPPED) HORIZONTALNOUNTLOCAHONS·DIMPLESPROVIDEDrnTOPPANEL, ANO BACK Of CABINET. IH c~ernn BOTlOM. HOLES PROVIDED 3.45 DIA. HORJZONUL HANGING HARDWARE T08E FIELD SUPPLIED SECONDAn DRAI PRltu.RlDRArn UP FLOW SI OPE COIi .L2S.4HP. (2PLACESJ• CAS SHIPPED I ~-~' □ ':Jo L HP• 22.2 TYP• HORlZ. LEFT I AS SHIPPED I UPFLOW CAS SHIPPED! A.:..C.ill.L Fig. 4-FJ4 -Metric (sheet 2) PRl~ARY ORA.I SECONDARY ORA.I HORlZ. RlGHT !FIELD CONVERTED) PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 35 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B FJ4: Product Data Table 1-PHYSICAL DATA NOMINAL COOLING DIMENSIONS -IN (mm) SHIPPING WEIGHT UNIT SIZE CAPACITY (Btuh) Height Width Depth LB (KG) 18 18,000 42-11/16 in. 14-5/16 in. 22-1 /1 6 in. 120 Singular (1084mm) (364mm) (560mm) (54.4) 24 24,000 49-5/8 in. 17-5/8 in. 22-1 /16 in. 131 Singular (1260mm) (448mm) (560mm) (59.4) 30 30,000 49-5/8 in. 17-5/8 in. 22-1 /1 6 in. 148 Singular (1260mm) (448mm) (560mm) (671) 36 36,000 49-5/8 in. 17-5/8 in. 22-1/1 6 in. 148 Singular (1260mm) (448mm) (560mm) (67.1) 42 42,000 49-5/8 in. 21-1/8 in. 22-1 /16 in. 166 Singular (1260mm) (537mm) (560mm) (75.3) 42 42,000 53-7/16 in. 21-1/8 in. 22-1 /1 6 in. 166 Modular (1357mm) (537mm) (560mm) (75.3) 48 48,000 53-7/16 in. 21-1/8 in. 22-1/16 in. 182 Singular & Modular (1357mm) (537mm) (560mm) (82 5) 60 60,000 59-3/16 in. 24-11/16 in. 22-1/16 in. 210 Singular & Modular (1503mm) (627mm) (560mm) (95.2) Table 2-SPECIFICATIONS SIZE 18 I 24 I 30 I 36 I 42 I 48 I 60 EVAPORATOR COIL Face Area (sq. II) 2.23 I 2.97 I 3.96 I 4.45 I 5.93 I 7.42 Configuration Slope I A Metering Device Puron® TXV FILTER SIZE (W x L) 13-in x 20-in I 16-in x 20-in I 20-in x 20-in I 23-in x 20-in (330.2 x 508 mm) (406.4 x 508 mm) ( 508 x 508 mm) (584.2 x 508.0 mm) BLOWER ASSEMBLY Motor Type (ECM) Multi-lap ECM Motor HP 1/3 I 1/3 I 1/2 I 1/2 I 1/2 I 3/4 I 3/4 CFM 525 I 700 I 875 I 1050 I 1225 I 1400 I 1750 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 7 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 36 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B FJ4: Product Data PERFORMANCE DATA Table 3 -Airflow Performance (CFM) Wet Ton Blower External Static (In. we) (Size) Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Tap 5 754 737 717 694 668 641 605 572 528 Tap 4 695 678 655 628 600 573 551 520 479 1-1/2 Tap 3 695 678 655 628 600 573 551 520 479 (18) Tap 2 643 620 591 557 534 506 477 439 408 Tap 1 487 448 428 394 358 325 281 NA NA Tap 5 1021 1003 964 925 876 838 797 761 726 Tap 4 936 907 873 805 779 732 696 661 626 2 Tap 3 936 907 873 805 779 732 696 661 626 (24) Tap 2 846 831 792 739 702 651 609 548 536 Tap 1 746 697 629 567 521 477 446 389 364 Tap 5 1247 1215 1188 1154 1122 1083 1053 1017 971 Tap 4 1133 1114 1082 1044 1009 968 924 873 835 2-1/2 Tap 3 1133 1114 1082 1044 1009 968 924 873 835 (30) Tap 2 1040 997 961 929 883 828 782 725 708 Tap 1 896 862 805 740 689 648 597 NA NA Tap 5 1433 1404 1363 1328 1282 1251 1201 1145 1095 Tap 4 1304 1277 1256 1230 1207 1168 1122 1080 1073 3 Tap 3 1304 1277 1256 1230 1207 1168 1122 1080 1073 (36) Tap 2 1183 1148 1124 1094 1051 1005 955 901 846 Tap 1 1020 995 958 921 881 840 791 735 693 Tap 5 1571 1551 1508 1473 1439 1407 1372 1317 1253 Tap 4 1517 1493 1458 1425 1392 1358 1328 1295 1253 3-1/2 Tap 3 1517 1493 1458 1425 1392 1358 1328 1295 1253 (42) Tap 2 1369 1339 1299 1263 1226 1188 1155 1112 1068 Tap 1 1260 1231 1172 1143 1077 1041 995 949 896 Tap 5 1896 1853 1821 1795 1760 1737 1702 1670 1665 Tap 4 1711 1673 1643 1607 1570 1549 1509 1490 1446 4 Tap 3 1711 1673 1643 1607 1570 1549 1509 1490 1446 (48) Tap 2 1547 1504 1466 1416 1388 1369 1324 1290 1239 Tap 1 1397 1347 1312 1269 1232 1172 1135 1086 1038 Tap 5 2109 2067 2043 1996 1967 1928 1899 1848 1812 Tap 4 2109 2067 2043 1996 1967 1928 1899 1848 1812 5 Tap 3 2109 2067 2043 1996 1967 1928 1899 1848 1812 (60) Tap 2 1901 1868 1825 1785 1737 1710 1662 1620 1584 Tap 1 1583 1557 1499 1451 1392 1358 1313 1259 1194 NOTES: 1. Airflow based upon dry coil at 230V with factory-approved filter and electric heater (2 element heater sizes 018 through 036, 3 element heater sizes 042 through 060). 2. To avoid potential for condensate blowing out of drain pan prior to making drain trap: Return static pressure must be less than 0.40 in. wc. Horizontal awlications of042 -060 sizes must have supply static greater than 0.20 in. wc. Airflow above 400 cfm/ton on 048-060 size could result in condensate blowing off coil or splashing out of drain pan. 3. At higher pextstats (above 0.6 in/we), water blow off is more likely to ocrur depencing on the user's setup. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 8 1.0 481 421 421 378 NA 689 591 591 491 326 915 785 785 667 NA 1021 983 983 783 649 1189 1193 1193 1012 867 1619 1411 1411 1200 989 1766 1766 1766 1521 1138 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 37 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B FJ4: Product Data PERFORMANCE DATA (cont.) Table 4-Airflow Performance (CFM) Dry Ton Blower External Static (In. we) (Size) Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Tap 5 762 741 721 698 672 656 635 577 547 Tap 4 695 679 655 628 600 580 559 534 505 1-1/2 Tap 3 695 679 655 628 600 580 559 534 505 (18) Tap 2 634 615 585 547 522 506 475 444 407 Tap 1 498 470 434 390 356 300 272 NA NA Tap 5 1046 1013 978 958 925 877 830 752 722 Tap 4 992 950 916 869 81 2 763 705 660 611 2 Tap 3 992 950 916 869 812 763 705 660 611 (24) Tap 2 900 862 814 769 709 644 594 548 507 Tap 1 762 723 651 599 531 471 428 385 345 Tap 5 1277 1244 1226 1193 1169 1122 1094 1058 1014 Tap 4 1179 1142 1114 1070 1039 998 937 915 867 2-1/2 Tap 3 1179 1142 1114 1070 1039 998 937 915 867 (30) Tap 2 1066 1030 997 960 916 863 795 746 703 Tap 1 923 878 832 784 723 658 616 563 NA Tap 5 1489 1463 1428 1388 1345 1305 1262 1213 1160 Tap 4 1357 1337 1310 1283 1249 1212 1165 1114 1064 3 Tap 3 1357 1337 1310 1283 1249 1212 1165 1114 1064 (36) Tap 2 1211 1190 1162 1132 1100 1066 1016 959 905 Tap 1 1059 1038 1004 967 925 887 843 791 747 Tap 5 1647 1620 1583 1548 1505 1464 1424 1379 1319 Tap 4 1569 1539 1506 1476 1442 1404 1370 1336 1299 3-1/2 Tap 3 1569 1539 1506 1476 1442 1404 1370 1336 1299 (42) Tap 2 1393 1355 1329 1288 1248 1223 1180 1138 1091 Tap 1 1265 1234 1195 1154 1111 1062 1022 964 914 Tap 5 1956 1917 1887 1855 1831 1798 1763 1743 1707 Tap 4 1773 1743 1704 1667 1634 1612 1571 1536 1500 4 Tap 3 1773 1743 1704 1667 1634 1612 1571 1536 1500 (48) Tap 2 1566 1524 1483 1451 1414 1376 1340 1303 1266 Tap 1 1413 1373 1328 1283 1246 1204 1168 1120 1075 Tap 5 2148 2123 2084 2048 2002 1974 1939 1891 1893 Tap 4 2148 2123 2084 2048 2002 1974 1939 1891 1893 5 Tap 3 2148 2123 2084 2048 2002 1974 1939 1891 1893 (60) Tap 2 1955 1913 1868 1833 1796 1757 1711 1654 1632 Tap 1 1646 1590 1527 1496 1442 1373 1315 1294 1221 NOTES: l.Airflow based upon dry coil at 230V with factory-approved filter and electric heater (2 element heater sizes 018 through 036, 3 element heater sizes 042 through 060). 2. To avoid potential for condensate blowing out of drain pan prior to making drain trap: Return static pressure must be less than 0.40 in. we. Horizontal awlications of042 -060 sizes must have supply static greater than 0.20 in. wc. Airflow above 400 cfm/ton on 048-060 size could result in condensate blowing off coil or splashing out of drain pan. 3. At higher pextstats (above 0.6 in/we), water blowoff is more likely to occur dependng on the user's setup. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 9 1.0 509 452 452 371 NA 687 585 585 451 319 969 825 825 674 NA 1093 1014 1014 838 681 1250 1219 1219 1037 865 1683 1464 1464 1217 1012 1812 1812 1812 1570 1164 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 38 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B FJ4: Product Data Unit Size 18 24 30 36 Table 5 -Gross Cooling Capacities INDOOR COIL SATURATED TEMPERATURE LEAVING EVAPORATOR (°F / °C) AIR 35/2 40/4 45/7 50/10 CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC 72/22 42.80 20.80 0.00 38.40 18.70 0.00 33.50 16.50 0.01 27.90 14.10 0.02 21.70 525 67/19 34.90 21.40 0.03 30.40 19.20 0.03 25.30 16.80 0.03 19.80 14.50 0.03 13.90 62/17 27.70 21.90 0.03 23.20 19.60 0.03 18.50 17.30 0.04 14.90 14.90 0.13 12.20 72/22 46.90 22.80 0.00 42.10 20.50 0.00 36.70 18.10 0.02 30.60 15.60 0.03 23.80 600 67/19 38.30 23.70 0.04 33.40 21.20 0.04 27.80 18.70 0.04 21.60 16.1 0 0.04 15.20 62/17 30.40 24.30 0.04 25.40 21 .80 0.04 20.30 19.30 0.06 16.50 16.50 0.15 13.60 72/22 50.60 24.60 0.00 45.40 22.20 0.02 39.60 19.70 0.03 33.00 17.00 0.04 25.60 675 67/19 41.40 25.70 0.05 36.10 23.10 0.05 30.10 20.40 0.05 23.40 17.60 0.05 16.50 62/17 32.90 26.60 0.05 27.50 23.90 0.05 22.10 21.10 0.07 18.10 18.10 0.17 14.90 72/22 54.40 26.40 0.00 49.20 24.00 0.00 43.30 21.40 0.01 36.40 18.50 0.02 28.60 700 67/19 44.80 27.70 0.03 39.30 25.00 0.03 33.00 22.10 0.03 26.00 19.10 0.03 18.50 62/17 35.80 28.60 0.03 30.20 25.80 0.03 24.30 22.90 0.04 19.70 19.70 0.13 16.30 72/22 59.10 28.70 0.00 53.50 26.20 0.01 47.00 23.40 0.02 39.70 20.30 0.03 31.20 800 67/19 48.70 30.40 0.04 42.90 27.60 0.04 36.10 24.50 0.04 28.30 21.20 0.04 20.20 62/17 39.10 31 .60 0.04 33.00 28.60 0.05 26.60 25.40 0.06 21.90 21 .90 0.16 18.10 72/22 63.20 30.80 0.00 57.20 28.20 0.02 50.40 25.20 0.04 42.60 22.00 0.04 33.50 900 67/19 52.30 32.80 0.05 46.10 29.90 0.05 38.90 26.70 0.05 30.50 23.20 0.05 21.80 62/17 42.10 34.50 0.05 35.60 31.30 0.06 28.80 27.90 0.07 24.00 24.00 0.18 19.80 72/22 71.60 34.70 0.00 64.40 31.30 0.00 56.30 27.70 0.00 47.20 23.80 0.02 36.80 875 67/19 58.70 36.00 0.02 51.30 32.30 0.03 42.90 28.40 0.03 33.60 24.40 0.03 23.70 62/17 46.70 36.80 0.03 39.20 33.00 0.03 31.20 29.10 0.04 25.00 25.00 0.12 20.60 72/22 78.30 38.00 0.00 70.50 34.40 0.00 61.60 30.50 0.02 51.70 26.30 0.03 40.30 1000 67/19 64.30 39.70 0.03 56.30 35.80 0.03 47.10 31.50 0.04 36.80 27.1 0 0.04 26.00 62/17 51.40 40.90 0.04 43.10 36.70 0.04 34.40 32.40 0.05 27.90 27.90 0.14 23.00 72/22 84.30 41 .00 0.00 75.90 37.20 0.00 66.80 33.20 0.02 55.80 28.60 0.04 43.60 1125 67/19 69.40 43.10 0.04 60.80 38.90 0.04 51 .00 34.50 0.05 39.80 29.70 0.05 28.10 62/17 55.60 44.80 0.05 46.70 40.30 0.05 37.30 35.60 0.06 30.60 30.60 0.16 25.20 72/22 64.89 33.39 0.00 58.38 30.18 0.00 51 .08 26.68 0.02 42.84 22.99 0.03 33.40 1050 67/19 53.14 34.96 0.04 46.48 31.47 0.04 38.88 27.72 004 30.22 23.74 0.04 21.13 62/17 42.35 36.1 8 0.04 35.45 32.44 0.04 28.12 28.54 0.05 22.73 22.73 0.15 18.64 72/22 70.55 36.42 0.00 63.54 32.99 0.02 55.62 29.26 0.03 46.67 25.30 0.04 36.48 1200 67/19 57.90 38.43 0.05 50.70 34.71 0.05 42.55 30.74 0.05 33.13 26.44 0.05 23.14 62/17 46.31 40.09 0.05 38.86 3609 0.05 31.02 31.87 0.07 25.31 25.31 0.17 20.78 72/22 75.52 39.17 0.00 68.14 35.55 0.03 59.70 31.64 0.04 50.12 27.45 0.05 39.26 1350 67/19 62.18 41.63 0.06 54.49 37.72 0.06 45.77 33.52 0.06 35.75 28.98 0.06 25.00 62/17 49.84 43.73 0.06 42.00 39.53 0.07 33.71 35.01 0.09 27.74 27.74 0.20 22.79 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 10 55/13 SHC BF 11.70 0.02 12.10 0.04 12.20 0.28 13.00 0.03 13.40 0.05 13.60 0.30 14.10 0.04 14.80 0.06 14.90 0.32 15.50 0.03 16.10 0.04 16.30 0.28 31.20 0.04 17.90 0.05 18.10 0.30 18.60 0.05 19.60 0.06 19.80 0.32 19.70 0.02 20.30 0.04 20.60 0.27 21 .90 0.03 22.70 0.05 23.00 0.29 23.80 0.04 24.90 0.06 25.20 0.31 19.04 0.03 19.74 0.05 18.64 0.29 21 .08 0.05 22.04 0.06 20.78 0.31 23.00 0.06 24.22 0.08 22.79 0.33 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 39 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B FJ4: Product Data Table 5 -Gross Cooling Capacities INDOOR COIL SATURATED TEMPERATURE LEAVING EVAPORATOR (°F / °C) Unit AIR 35/2 40/4 45/7 50/10 55/13 Size CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF 72/22 79.15 40.41 0.00 70.85 36.31 0.00 61 .59 31.90 0.02 51.15 27.24 0.03 39.41 22.38 0.04 1225 67/19 64.55 42.04 0.04 56.05 37.58 0.04 46.51 32.90 0.04 35.85 28 04 0.04 24.90 23.25 0.05 62/17 51.09 43.18 0.04 42.46 38.53 0.05 33.59 33.84 0.06 27.05 27.05 0.15 22.11 22.11 0.30 72/22 86.34 44.20 0.00 77.30 39.79 0.01 67.22 35.05 0.03 55.91 30.07 0.04 43.10 24.80 0.05 42 1400 67/19 70.55 46.30 0.05 61.37 41.55 0.05 50.95 36.50 0.05 39.20 31.18 0.06 27.27 25.94 007 62/17 56.04 47.92 0.06 46.63 42.89 0.06 36.98 37.71 0.08 30.12 30.12 0.18 24.63 24.62 0.32 72/22 92.81 47.68 0.00 83.15 42.98 0.03 72.31 37.96 0.05 60.17 32.67 0.06 46.45 27.07 0.06 1575 67/19 76.00 50.25 0.06 66.13 45.22 0.06 55.01 39.88 0.07 42.37 34.20 0.07 29.47 28.50 0.08 62/17 60.57 52.40 0.07 50.47 47 01 0.07 40.22 41.43 0.09 3301 3301 0.20 26.99 26.99 0.34 72/22 83.95 44.30 0.00 75.71 40.05 0.00 66.36 35.45 0.01 55.84 30.58 0.02 43.82 25.38 0.03 1400 67/19 68.80 46.22 0.03 60.32 41.61 0.03 50.67 36.70 0.03 39.64 31.45 0.03 27.80 26.12 0.04 62/17 54.96 47.71 0.03 46.12 42.77 0.03 36.69 37.67 0.04 29.32 29.32 0.13 24.10 24.10 0.28 72/22 91.53 48.40 0.00 82.59 43.90 0.00 72.47 38.97 0.02 61.02 33.73 0.03 48.01 28.16 0.04 48 1600 67/19 75.19 50.91 0.04 65.98 45.99 004 55.57 40.75 0.04 43.57 3509 0.04 30.49 29.21 0.05 62/17 60.21 52.94 0.04 5073 47.68 0.04 40.48 42.10 0.06 32.72 32.72 0.15 26.92 26.92 0.30 72/22 98.31 52.15 0.00 88.79 47.39 0.02 77.99 42.21 0.03 65.70 36.65 0.04 51.81 30.76 0.05 1800 67/19 80.94 55.25 0.05 71.10 5006 0.05 59.93 44.50 0.05 47.14 38.52 0.05 32.96 32.14 0.06 62/17 64.96 57.83 0.05 54.92 52.30 0.05 44.06 46.35 0.07 35.97 35.97 0.17 29.59 29.59 0.31 72/22 118.17 60.42 0.00 106.56 54.57 0.00 93.41 48.24 0.02 78.64 41 .59 0.02 62.13 34.63 0.03 1600 67/19 96.74 62.87 0.03 84.83 56.56 0.03 71.43 49.91 0.03 56.41 42.93 0.03 39.37 35.48 0.04 62/17 77.24 64.78 0.03 65.10 58.16 0.03 51.83 51.23 0.04 41.00 41.00 0.12 33.67 33.67 0.27 72/22 129.14 66.15 0.00 116.46 59.92 0.00 102.18 53.13 0.02 8608 45.94 0.03 68.00 38.39 0.03 60 1750 67/19 105.94 69.36 0.04 92.95 62.59 0.04 78.33 55.41 0.04 61.93 47.86 0.04 43.49 39.82 0.05 62/17 84.76 71.94 0.04 71.53 64.80 0.04 57.37 57.38 0.05 45.94 45.94 0.14 37.65 37.65 0.29 72122 139.03 71.41 0.00 125.46 64.82 0.01 110.15 57.64 0.03 92.83 49.99 0.04 73.33 41.92 0.04 2000 67/19 114.27 75.38 0.05 100.34 68.21 0.05 84.61 60.58 0.05 66.92 52.51 0.05 47.25 43.94 0.06 62/17 91.59 78.67 0.05 77.41 71.08 0.05 62.32 63.11 0.07 50.60 50.60 0.16 41.54 41.54 0.31 CFM -Cubic Fl per Minute EWB -Entering Wet Bulb 0f (°C) LWB -Leaving Wet Bulb 0f (0C) TC -Gross Cooling Capacity 1000 Btuh SHC-Gross Sensible Capacity 1000 Btuh BF -Bypass Factor MBH - 1000 Btuh NOTES: SHC CORRECTION FACTOR 1. Contact manufacturer for cooling capacities at conditions other than shown in table. ENTERING AIR DRY-BULB TEMPERATURE (°F) 2. Formulas: 79 78 77 76 75 Under 75 81 82 83 84 85 Over 85 Leaving db = entering db -sensible heat cap l.09x CFM Leaving wb = wb corresponding to enthalpy of air leaving coil (hlwb) h1wb = hcwb -total capacity (Btuh) BYPASS ENTERING AIR DRY-BULB TEMPERATURE (°C) FACTOR 4.5 xCFM where hcwb = enthalpy of air entering coil. Direct interpolation is permissible. Do not extrapolate. 3. SHC is based on 80°F (27°C) db temperature of air entering coil. Below 80°F (27°C) db, subtract (Correction Factor x CFM) from SHC. Above 80°F (27°C) db, add (Correction Factor x CFM) to SHC. 4. Bypass Factor= 0 indicates no psychometric solution. Use bypass factor of next lower EWB for approximation. 26 25 25 24 27 28 28 29 Correction Factor 0.10 .098 1.96 2.94 3.92 0.20 0.87 1.74 2.62 3.49 0.30 0.76 1.53 2.29 3.05 Interpolation is pem1issible. Correction Factor= 1.09 x (1 • BF) x (db-80) Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 11 24 Under 75 29 Over 85 4.91 Use 4.36 formula shown 3.82 below PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 40 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B FJ4: Product Data PERFORMANCE DATA (cont.) Table 6-Electric Heater Static Pressure Drop (in we) SIZES SIZES 18 -36 42 -60 HEATER EXTERNAL STATIC HEATER EXTERNAL STATIC ELEMENTS kW PRESSURE ELEMENTS kW PRESSURE CORRECTION CORRECTION 0 0 +.02 0 0 +.04 1 3, 5 +.01 1 3, 5 +.03 2 8, 10 0 2 8, 10 +.02 3 9, 15 -.02 3 9, 15 0 4 20 -.04 4 20 -.02 6 18, 24, 30 -.10 The airtlow perfonnance data was developed using fan coils with 10-kW electric heaters (2 elements) in the 018 through 036 size units and 15-kW heaters (3 elements) in the 042 through 061 size units. For fan coils with heaters ofa different number of elements, the external available static at a given CFM from the curve may be corrected by adding or subtracting available external static pressure as indicated above. Table 7 -Minimum CFM and Motor Speed Selection HEATER kW SIZE 3 5 8 9 10 15 18 20 24 18 525 525 525 -600 ---- 24 700 700 700 -700 775 --- 30 -875 875 -875 875 -1060 - 36 -1050 970 970 970 920 -1040 - 42 --1225 1225 1225 1225 1225 1225 - 48 --1400 1400 1400 1400 1400 1400 1400 60 --1750 1750 1750 1750 1750 1750 1750 Speed Tap 4 (white wire) is used for electric heat ooly. White wire must remain on tap 4. Table 8 -Estimated Sound Power Level ( dBA)• CONDITIONS OCTAVE BAND CENTER FREQUENCY SIZE Ext Static CFM Pressure 63 125 250 500 1000 2000 18 525 0.50 70.8 66.8 62.8 59.8 57.8 55.8 24 700 0.50 72.0 68.0 64.0 61.0 59.0 57.0 30 875 0.50 73.0 69.0 65.0 62.0 60.0 58.0 36 1050 0.50 73.8 69.8 65.8 62.8 60.8 58.8 42 1225 0.50 74.4 70.4 66.4 63.4 61.4 59.4 48 1400 0.50 75.0 71.0 67.0 64.0 62.0 60.0 60 1750 0.50 76.0 72.0 68.0 65.0 63.0 61.0 * Estimated sound power levels have been derived using the method described in the 1987 ASHRAE HVAC Systems & Applications Handbook, Chapter 52, p. 52.7. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 12 30 - - - - - 1400 1750 4000 51.8 53.0 54.0 54.8 55.4 56.0 57.0 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 41 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B FJ4: Product Data PERFORMANCE DATA (cont.) Table 9-EH Heater Table HEATER kW VOLTS/PH STAGES(kW INTERNAL CIRCUIT FAN COIL SIZE USED PART NO. @240V OPERATING) PROTECTION WITH KFFEH8401 N03 3 230/1 3 None 18 KFFEH8501 NOS 5 230/1 5 None 18 KFFEH8801 N08 8 230/1 8 None 18 KFFEH8901 N10 10 230/1 10 None 18 KFFEH0401 N03 3 230/1 3 None 24-25 KFFEH0501 NOS 5 230/1 5 None 24-60 KFFEH0801 NOB 8 230/1 8 None 24-60 KFFEH0901 N10 10 230/1 10 None 24-60 KFFEH3201 F20 20 230/1 5, 20 Fuset 30-60 KFFEH8401 COS 5 230/1 5 Circuit Breaker 18 KFFEH8501 COB 8 230/1 8 Circuit Breaker 18 KFFEH8601C10 10 230/1 10 Circuit Breaker 18 KFFEH2401 COS 5 230/1 5 Circuit Breaker 24-60 KFFEH2501 COB 8 230/1 8 Circuit Breaker 24-60 KFFEH2601C10 10 230/1 10 Circuit Breaker 24-60 KFFEH3301 C20 20 230/1 5, 20 Circuit Breaker 30-60 KFFEH2901 N09 9 230/1+ 3, 9 None 36-60 KFFEH3001F15 15 230/1 5, 15 Fuset 24-60 KFFEH3101C15 15 230/1 5, 15 Circuit Breaker 24-60 3 Phase Only KFFEH1601315 15 230/3 5, 15 None 36-60 KFFEH2001318 18 230/3 6, 12, 18 None 42-60 3 Phase, Factory Shipped (field convertible to single phase) KFFEH3401 F24 24 230/3 KFFEH3501 F30 30 230/3 *. Does not indude heat :from blower mater. t-Single point wiring kit required for these heaters. !, Field coovertible to 3 phase. 8, 16, 24 Fuse 48, 60 10, 20, 30 Fuse 48, 60 Table 10-Electrical Data for Units without Electric Heat SINGLE CIRCUIT MODEL SIZE MTR MTR VOL TSIPH/HZ MAXMUM HP FLA MCA OVERCURRENT PROTECION 18 1/3 2.9 208/230/1 /60 3.6 15 24 1/3 2.9 208/230/1 /60 3.6 15 30 1/2 4.2 208/230/1 /60 5.3 15 36 1/2 4.2 208/230/1 /60 5.3 15 42 1/2 4.2 208/230/1 /60 5.3 15 48 3/4 6.1 208/230/1 /60 7.6 15 60 3/4 6.1 208/230/1 /60 7.6 15 HEATING CAP.' @230V 9.400 15.700 25,100 31,400 9,400 15,700 25,100 31,400 62,800 15,700 25,100 31,400 15,700 25,100 31,400 62,800 28,200 47,100 47,100 47,100 56,500 78,300 94,100 BRANCH CIRCUIT MIN WIRE SIZE* AWG 14 14 14 14 14 14 14 * Use copper wire only. Use75 °Conly in tbisapplicatioo. When using non-metallic (NM) sheathed cable, wire Sze required should be based on 1hatof60°C conductors. instead of wire sizes shown in talie aboveperNECArticle336-26. NOTE: If branch circuit wire length exceeds 100 ft (30 m), consult NEC 215-2 to determine maximwn wire length. Use 2% voltage drop. FLA • Full LoadAmps SCCR (Short Circuit Current Ra1ing) -5kA rms, synnne1rical, 230V Manufacturer reserves the rli,,t to change, at any time, specifications and designs without notice and without obllgatlons. 13 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 42 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B FJ4: Product Data PERFORMANCE DATA (cont.) Table 11-Electrical Data for Units with Factory-Installed Heat Single Circuit Dual Circuit Size Motor Motor Volts Heat Pack Heater MCA MOCP Heater MCA MOCP HP FLA I Ph/ Hz Installed Heater MCA MOCP Amps Amps Amps L 1/L2 L 1/L2 L 1/L2 L3/L4 L3/L4 L3/L4 018L05 113 2.9 208/23011160 MKFFEH8501N05A 18.1120.0 26.3/28.6 30130 NIA NIA NIA NIA NIA NIA 018L08 113 2.9 2081230/1160 MKFFEH8801N08A 28.9/32.0 39.8/43.6 45150 NIA NIA NIA NIA NIA NIA 024L05 113 2.9 208/23011160 MKFFEH0501N05A 18.1120.0 26.3/28.6 30130 NIA NIA NIA NIA NIA NIA 024L10 113 2.9 208/23011160 MKFFEH0901N10A 36.2/40.0 48.9153.6 50160 NIA NIA NIA NIA NIA NIA 030L08 112 4.2 208/23011160 MKFFEH0801N08A 28.9132.0 41.4145.3 45150 NIA NIA NIA NIA NIA NIA 030L 10 112 4.2 208/23011160 MKFFEH0901N10A 36.2/40.0 50.5/55.3 60160 NIA NIA NIA NIA NIA NIA 036L 10 112 4.2 208/23011160 MKFFEH0901N10A 36.2/40.0 50.5/55.3 60160 NIA NIA NIA NIA NIA NIA 036L15 112 4.2 208/23011160 MKFFEH1501F15 54.2/59.9 73.0180.1 80190 36.2/40.0 50.5155.3 60160 18.1120.0 22.6125.0 25/25 042L10 112 4.2 2081230/1160 MKFFEH0901N10A 36.2/40.0 50.5155.3 60/60 NIA NIA NIA NIA NIA NIA 042L 15 112 4.2 208/23011160 MKFFEH1501F15 54.2/59.9 73.0190.1 80190 36.2/40.0 50.5155.3 50160 18.1120.0 22.6125.0 25/25 048L 10 3/4 6.1 208/23011160 MKFFEH0901 N10A 36.2/40.0 52.9157.6 60160 NIA NIA NIA NIA NIA NIA 048L 15 3/4 6.1 2081230/1 /60 MKFFEH1501F15 54.2/59.9 75.4/82.5 80/90 36.2/40.0 52.9/57.6 60/60 18.1120.0 22.6125.0 25125 HEATER ELECTRICAL DATA Table 12-Electric Heater Internal Protection HEATER kW PHASE FUSE QTY/SIZE CKT BKR' QTY/SIZE 5 1 -1/60 8 1 -1/60 9 1/3 -- 10 1 -1/60 15 1 2/30-2/60 2/60 15 3 -- 18 3 -- 20 1 4/60 2/60 24 1/3 6/60 - 30 1/3 6/60 - * All circuit breakers are 2 pole. 'When using units with 20-, 24-, and 30-kW electric heaters, maintain a 1-in. (25mm) clearance from combustible materials to discharge plenum and ductwork and maintain a dstance of36-in (914mm) frcm the unit. Use an accessory down.flow base to maintain proper clearance on downflow installations. Use flexible connectors between ductwork and unit to prevent transmission of vibration. 'When electric heater is installed, use heat resistant material for flexible connector between ductwork and unit at discharge connection. Ductwork passing through unconditioned space must be insulated and covered with vapor barrier. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 14 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 43 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B PERFORMANCE DATA (cont.) Table 1J-Acet>ssory Healer Ek>ctrical Data HEATER AMPS ,.._NAWACJTY BRANCH CIRCUIT • INTERNAL Mnw;~~~~WC) Min Cnd Wire Size Max FuselClct Bkr HEATER PART NO. kW H CIRCUIT 2081230V 2081230V 2081230V Amps 2081230V :e PROTECTION Single DualClrC\111 $Ingle Dual Circuit Slngle Dual Circuit Single Dual Circuit Single DuaJClreult ~208V Circuit L1,L2 Ll,L-4 Circuit L1,L2 Ll,L-4 Clrcuil l1,L2 L~LA Circuit L1,L2 Ll,LA Cin:ut L1,L2 L3,U KFFEH0401 N03A 3 2.3 Nooo 10.9112.0 17.3118.6 12/12 12/12 2<>'20 KFFEH8404N03A 2.3 Nooo 10.9112.0 17.3118.6 12/12 12/12 2<1120 KFFEH0501N05Atl 3.8 1 Nooo 18.1/20.0 26.Q/28.4 10/10 10/10 30'30 KFFEH8501 N05A 3.8 1 Nooo 18.1/20.0 26.3/28.6 10/10 10/10 30/30 KFFEH8501 C05A 3.8 1 Nooo 18.1120.0 26.3/28.6 10/10 10/10 30/30 KFFEH0501N05A" 38 1 Nooo 18.1/20.0 31.2/33.5 "" 10/10 35135 KFFEH2401C05A .. l .8 1 c•""' 18.1/20.0 31.2/33.5 "" 10/10 35135 KFFEH0801 NOBA • 0 1 Nooo 28-9132.0 44.7/48.5 "" 10/10 4 .... 0 KFFEH8801 N08A 6.0 Nooo 28.9132.0 39.8143.6 "" 10/10 4 .... 0 KFFEH8501C08A. 6.0 Nooo 28.9132.0 39.8143.6 818 10/10 4 .... 0 KFFEH2S01C08A. '0 Ckt Bkr 28.9132.0 44.7148.5 818 10/10 4 .... 0 KFFEH2901N09A 6.8 Nooo 32.8136.0 49.5'53.5 "' 10/10 50}60 KFFEH2901NOMtt 6.8 ' Nooo 18.8/20.8 32.<ni.5 "" 10/10 >5135 KFFEH0901 N10A 10 7.5 1 Nooo 36.2/40.0 53.8158.5 616 10/10 60'60 KFFEH8901 N10A 10 7.5 1 Nooo 36.2140.0 48.9153.6 616 10/10 60'60 KFFEH8601CHIA 10 7.5 Nooo 36.2/40.0 48.9/53.6 "' 10/10 60'60 KFFEH2601C10A 10 7.5 Ck1 Bkr 36.2140.0 53.8158.5 "' 10/10 """' KFFEH3001F1l1Atl 15 11.3 1 ,, .. 54.2159.9 36.2140.0 18.1/20.0 76.3183.4 :53.8158.5 22.7/25.0 414 616 1Qf10 "" 10,10 10/10 81)'9() 6(Y60 25125 KFFEH3101C15A 15 11.3 Ckt Bkr 36.1/40.0 18.1/20.0 :53.8158.5 22.7/25.0 "' 1Qf10 10110 10/10 6(Y60 25125 KFFe-t1601316A 15 11.3 Nooo 31.3134.6 47,7/51.8 ... 10/10 50}60 KFFEH200131BA " 13.5 3 Nooo 37.6.141.5 55.5160.4 616 10'8 60/70 KFFEH3201F20AH 20 15.0 1 ,, .. 72.3179.8 36.1/40.0 36.2140.0 88.81108.4 :53.8158.5 45.3150.0 312 616 .,. "' 10110 10/10 100/110 6(Y60 50/50 KFFEJ-13301 C20A 20 15.0 Ckt Bkr 36.2/40.0 36.2140.0 :53.8158.5 45.3/50.0 616 .,. 10fl0 10/10 60'60 50/50 KFFEH3401 F24A ... 24 18.0 '"'' 50.1155.4 71.2/n.8 414 ... 80/80 24 18.0 1 ,, .. 86.7195.5 116.81127.9 1N "' 1251150 KFFEH3501 F30A0 .. 30 225 3 ,, .. 62.6169.2 88.8196.0 313 ... 90/100 30 22.5 1 ,, .. 109.0/120.0 144,&'158.5 0/00 616 1501175 •. lododn: blow et mouw ampt: of lll!toll fan ooil used wilb beaur. t-Copper11i·ire DlllSf be1111ed. lf01bu lb1n un«111ed(ooo-pllled). 73"C 1mbien1,wpperwire (tolid 11i·ire !Of 10 AWO and smaller, etnndotdwire for l11Atrlb1n 10 AWO) is used, cooillll applicable hble11 oflbeNEC(A.NSUNFPA 10). t-Forflneoilliizes:U-42. ".Forf1neoil9izes4S-<60. if. Pifldco1wcrtiblt-toJpl'ul11t. ll-Single circuit tpplication o(FI, •nd F20 hn tersnquirn liinglt-•point wiring kit 1«nsory. •••.f"ield convertible lo I phau, .,,;n.§le or multiple -Wy dmiil Table 14-Field M ulllpolnt Wiring or 24--and 30-k\V Single Phaw HEATER PART NO. kW PHASE HEATER At.PS 2081230V MIN At.PA.CITY 2081230V. f.tN WIRE SIZE (AWG) 208/230vt 240V 208V L1,L2 I L3,l.4 I L5,LIJ L1.L2 I L3,L4 I L5,Lli Ll,L2 I L3,L◄ LS,Lli KFFEH3401F24 •• 24 18.0 28.91l2.o I za.9132.0 I 20.9132.0 44. 1He.5 I 36.2.140.0 I 36.2140.o "" I 8m .,. KFFEl-!3501 F30 30 22.5 36.2140.o I 36.2140.o I 36.2140.o 53.8158.5 I 45.MO.O I 45.3150.0 "' I 8m .,. •. lndudtt:H0Wff mol<>t ampt:0flll!toll fan ooil osedwilb be-ahr. MIN GHO MAX FUSEJCKTBKR MAX WIR.E LENGTH WIRE SIZE AMPS 20&/230V 208J230V (FT)°' 20&'2J0V L 1,L2 I L3,L◄ I L5,L6 L1,L2 I L3,L4 LS,Lli 10'10 4SJSO I 40J4o I 40J4o s918o I 73n3 7,m 1()'10 60/60 I SOM I SOM 78180 J 59~9 """' f. Copper11i·ire moSf be11,ed.1f01btrlbtn un«111ed(ooo-pllled). 73"C ambient,ropperwire (tolid 11i·i1e !Of 10 AWO andamalltr, Nrllldedwire for l11ger1h1n 10 AWO) isus-ed.. cooillll tR)licable hblet oflbeNEC(ANSUNFPA 10). l-Lfflglh dlolli·n is timnwrtd I WI)' along 11iire p.01 belWeen uni I andsetVi(eptnel for 1voltqedropn011oexned2,-. ••. fitld (Uwcrtiblelo I phut-, linglt or multiple aipply cim1it. PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 44 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B FJ4: Product Data Table 15 -Accessories ITEM ACCESSORY PART NO.* FAN COIL SIZE USED WITH 1. Disconnect Kit KFADK0301 DSC All single phase 3kW-10kW heaters KFACB0101 CF B 18 2. Downflow Base Kil KFACB0201CFB 24, 30, 36 KFACB0301CFB 42, 48 KFACB0401CFB 60 KFADC0201 SLP Slope Coil Units-18, 24 3. Oownflow Conversion Kitt KFADC0401 AGL A-Coil Units-30, 36, 42, 48, 60 4. Downflow/Horizootal Conversioo Gasket Kil KFAHD0101 SLP All 5. Horizontal Water Management Kit (25 pack) t KFAHC0125AAA A-Coil Units-30, 36, 42, 48, 60 6. Single-Point Wiring Kil KFASP0101 SPK Only with 15-and 20-kW Fused Heaters 7. Filter Available at retail big-box hardware stores. See Table 2 for sizes. FNCCABCC0014 (FILXXFNC0014) Fan Coil Filter Cabinet FNCCABCC0017 (FILXXFNC0017) 8. (Fan Coil Filter Media) FNCCABCC0021 (FILXXFNC0021) FNCCABCC0024 (FILXXFNC0024) 9. PVC Gooden sate Trap Kit (50 pack) KFAET0150ETK KSBTX0201 PU R KSBTX0301 PUR 10. TXV Kit, Puron (R-410A), Aluminum Coils Only KSBTX0401 PUR KSBTX0501 PU R 11. Door Gasket Kit •• 344994-751 12. Accessory Quick Coonect Kit KFAPS0110KIT * Factory authorized and listed, field•installed. ** This kit is for replacement of factory installed gaskets if they are damaged or removed from the fan coil. t KFAHD0I0lSLP must also be purchased for down flow applications. t KFAHDOl0lSLP must also be purchased for down flow or horizontal applications. 18 24, 30, 36 42, 48 60 All 18L, 24L, 30L, 36L, 42L 48L 60L 60L All All Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 16 PWM25-3498FAC Faraday Heat Pump #8 Split System Replacement Page 45 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B FJ4: Product Data Accessory Kits Description -Suggested and Required Use I. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or mamtenance may be performed safely. SUGGESTED USE: Units for 3-through I 0-kW electric resistance heaters and cooling controls. 2. Downflow Base Kit This kit is designed to provide a I-in. (25mm) minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides a gap-free seal with the floor. REQUIRED USE: This kit must be used whenever fan coils are used in downflow applications. 3. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal-left applications. Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications. Separate kits are available for slope coils and A-coils. REQUIRED USE: This kit must be used whenever fan coils are used in downflow applications. 4. Downflow/Horizontal Conversion Gasket Kit This kit provides the proper gasketing of units when applied in either a downflow or horizontal application. REQUIRED USE: Fan coils in either downflow or horizontal applications. 5. Horizontal Applications -Water Management Kit This kit provides proper installation of fan coils under conditions of high static pressure and high relative humidity. SUGGESTED USE: All fan coils. 6. Single Point Wiring Kit The single point wiring kit acts as a jumper between LI and L3 lugs, and between the L2 and L4 lugs. This allows the installer to run two heavy-gauge, high-voltage wires into the fan coil rather than 4 light-gauge, high-voltage wires. SUGGESTED USE: Fan coils with 15-and 20-kW fused heaters only. 7. Filter Kit (12 pack) The kit consists of 12 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and, in hnn, the efficiency of the system. SUGGESTED USE: To replace filters in fan coils. REQUIRED USE: All units unless a filter grille is used. 8. Fan Coll Filter Cabinet This cabinet is mounted to the fan coil on the return air end and designed to slip over the outer fan coil casing. The cabinets are insulated using the same insulation as production fan coils. They are designed for the removal of particulates from indoor air using FILXXFNC00(l4, 17, 21, 24) media filter cartridges. These fan coil media filter cartridge kits are designed for the removal of particles from indoor air. The cartridge is installed in the return air duct next to the air handler or further upstream. SUGGESTED USE: All fan coils. 9. PVC Condensate Drain Trap Kit This kit consists of 50 PVC condensate traps. Each trap is pre-formed and ready for field installation. This deep trap helps the system make and hold proper condensate flow even during blower initiation. SUGGESTED USE: All fan coils. 10. TXVKlt These kits are designed to add TXVs to piston fan coils or convert Puron (R-410A) fan coils to R-22 TXVs. 11. Door Gasket Kit This kit consists of specific adhesive-backed foam strips which are applied to the unit door and frame, limiting air leakage. 12. Accessory Quick Connect Kit This kit enables the installer to easily connect a 230V IAQ accessory (air purifier, electronic air cleaner, UV light, etc.) kit to a fan coil unit, eliminating the need to run a separate power supply to the accessory. Use of this kit may eliminate the requirement for a licensed electrician to complete the job ( check local codes). © 2022 Carrier. All rights reserved. Edition Date: 12/22 Catalog No: FJ4D-0IPD Manufacturer reserves the rli,,t to ch111ge, at any time, specifications and designs without notice and without obllgatlons. 17 Replaces:: New SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. INSURER(S) AFFORDING COVERAGE INSURER F : INSURER E : INSURER D : INSURER C : INSURER B : INSURER A : NAIC # NAME:CONTACT (A/C, No):FAX E-MAILADDRESS: PRODUCER (A/C, No, Ext):PHONE INSURED REVISION NUMBER:CERTIFICATE NUMBER:COVERAGES IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. OTHER: (Per accident) (Ea accident) $ $ N / A SUBR WVD ADDL INSD THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THISCERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. $ $ $ $PROPERTY DAMAGE BODILY INJURY (Per accident) BODILY INJURY (Per person) COMBINED SINGLE LIMIT AUTOS ONLY AUTOSAUTOS ONLY NON-OWNED SCHEDULEDOWNED ANY AUTO AUTOMOBILE LIABILITY Y / N WORKERS COMPENSATION AND EMPLOYERS' LIABILITY OFFICER/MEMBER EXCLUDED?(Mandatory in NH) DESCRIPTION OF OPERATIONS belowIf yes, describe under ANY PROPRIETOR/PARTNER/EXECUTIVE $ $ $ E.L. DISEASE - POLICY LIMIT E.L. DISEASE - EA EMPLOYEE E.L. EACH ACCIDENT EROTH-STATUTEPER LIMITS(MM/DD/YYYY)POLICY EXP(MM/DD/YYYY)POLICY EFFPOLICY NUMBERTYPE OF INSURANCELTRINSR DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) EXCESS LIAB UMBRELLA LIAB $EACH OCCURRENCE $AGGREGATE $ OCCUR CLAIMS-MADE DED RETENTION $ $PRODUCTS - COMP/OP AGG $GENERAL AGGREGATE $PERSONAL & ADV INJURY $MED EXP (Any one person) $EACH OCCURRENCE DAMAGE TO RENTED $PREMISES (Ea occurrence) COMMERCIAL GENERAL LIABILITY CLAIMS-MADE OCCUR GEN'L AGGREGATE LIMIT APPLIES PER: POLICY PRO-JECT LOC CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) CANCELLATION AUTHORIZED REPRESENTATIVE ACORD 25 (2016/03) © 1988-2015 ACORD CORPORATION. All rights reserved. CERTIFICATE HOLDER The ACORD name and logo are registered marks of ACORD HIREDAUTOS ONLY 2/26/2024 Burnham WGB Insurance SolutionsCA Insurance License 0F6977115901 Red Hill AvenueTustin CA 92780 Bobbie Mace 714-824-8373 714-573-1770 Bobbie.Mace@wgbib.com Middlesex Insurance Co 23434 SEASI-1 Insurance Company of the West 27847Seaside Heating & Air Conditioning, Inc.1359 Rocky Point Dr.Oceanside CA 92056-5864 2041081098 A X 1,000,000 X 100,000 X 1,000 5,000 1,000,000 3,000,000 Y Y A0112596004 9/18/2023 9/18/2024 2,000,000 A 1,000,000 X X X X Comp $500Ded X Coll $500Ded Y Y A0112596001 9/18/2023 9/18/2024 A X X 5,000,000YA01125960049/18/2023Y 9/18/2024 5,000,000 X NIL B XYWSD5025920 10 3/1/2024 3/1/2025 1,000,000 1,000,000 1,000,000 City of Carlsbad/CMWD, its officers, officials, employees, agents and volunteers are named as additional insured on the General Liability per attached CG 2010 04 13 and CG 20 37 04 13 as required by written contract subject to the terms and conditions of the policy. Waiver of Subrogation applies to the Workers'Compensation per attached WC 99 06 34. City of Carlsbad/CMWDc/o EXIGIS Insurance Compliance ServicesP.O. Box 947Murrieta CA 92564 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B ACORD® I ~ I ~ □ □ ~ ~ Fl □ □ ~ ~ ~ ~ ~ ~ ~ ~ H I I I I I □ I POLICY NUMBER: © Insurance Services Office, Inc., 2012 COMMERCIAL GENERAL LIABILITY CG 20 37 04 13 THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. ADDITIONAL INSURED - OWNERS, LESSEES OR CONTRACTORS - COMPLETED OPERATIONS This endorsement modifies insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART PRODUCTS/COMPLETED OPERATIONS LIABILITY COVERAGE PART SCHEDULE Name Of Additional Insured Person(s) Or Organization(s) Location And Description Of Completed Operations City of Carlsbad/CMWD c/o EXIGIS Insurance Compliance Services All locations and jobs performed that have a written contract, agreement or permit Information required to complete this Schedule, if not shown above, will be shown in the Declarations. A.Section II - Who Is An Insured is amended to include as an additional insured the person(s) or organization(s) shown in the Schedule, but only with respect to liability for "bodily injury" or "property damage" caused, in whole or in part, by "your work" at the location designated and described in the Schedule of this endorsement performed for that additional insured and included in the "products-completed operations hazard". However: 1.The insurance afforded to such additional insured only applies to the extent permitted by law; and 2.If coverage provided to the additional insured is required by a contract or agreement, the insurance afforded to such additional insured will not be broader than that which you are required by the contract or agreement to provide for such additional insured. B.With respect to the insurance afforded to these additional insureds, the following is added to Section III - Limits Of Insurance: If coverage provided to the additional insured is required by a contract or agreement, the most we will pay on behalf of the additional insured is the amount of insurance: 1.Required by the contract or agreement; or 2.Available under the applicable Limits of Insurance shown in the Declarations; whichever is less. This endorsement shall not increase the applicable Limits of Insurance shown in the Declarations. A0112596004 Change effective 09/18/2023 Page 1 of 1CG 20 37 04 13 10/02/2023A0112596 Middlesex Insurance Company 00001 0000000000 23275 0 N1 444eea33-7121-408b-9578-871e79483b54444eea33-7121-408b-9578-871e79483b54 Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B Change effective 09/18/2023 Page 1 of 2CG 20 10 04 13 10/02/2023A0112596 Middlesex Insurance Company POLICY NUMBER: © Insurance Services Office, Inc., 2012 COMMERCIAL GENERAL LIABILITY CG 20 10 04 13 THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. ADDITIONAL INSURED - OWNERS, LESSEES OR CONTRACTORS - SCHEDULED PERSON OR ORGANIZATION This endorsement modifies insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART SCHEDULE Name Of Additional Insured Person(s) Or Organization(s)Location(s) Of Covered Operations City of Carlsbad/CMWD c/o EXIGIS Insurance Compliance Services All locations per written contract, agreement or permit Description: All jobs performed that have a written contract, agreement or permit Information required to complete this Schedule, if not shown above, will be shown in the Declarations. A.Section II - Who Is An Insured is amended to include as an additional insured the person(s) or organization(s) shown in the Schedule, but only with respect to liability for "bodily injury", "property damage" or "personal and advertising injury" caused, in whole or in part, by: 1.Your acts or omissions; or 2.The acts or omissions of those acting on your behalf; in the performance of your ongoing operations for the additional insured(s) at the location(s) designated above. However: 1.The insurance afforded to such additional insured only applies to the extent permitted by law; and 2.If coverage provided to the additional insured is required by a contract or agreement, the insurance afforded to such additional insured will not be broader than that which you are required by the contract or agreement to provide for such additional insured. B.With respect to the insurance afforded to these additional insureds, the following additional exclusions apply: This insurance does not apply to "bodily injury" or "property damage" occurring after: 1.All work, including materials, parts or equipment furnished in connection with such work, on the project (other than service, maintenance or repairs) to be performed by or on behalf of the additional insured(s) at the location of the covered operations has been completed; or 2.That portion of "your work" out of which the injury or damage arises has been put to its intended use by any person or organization other than another contractor or subcontractor engaged in performing operations for a principal as a part of the same project. A0112596004 00001 0000000000 23275 0 N1 c7296a25-6a96-4fec-ab73-bade3ff0758bc7296a25-6a96-4fec-ab73-bade3ff0758b Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B C.With respect to the insurance afforded to these additional insureds, the following is added to Section III - Limits Of Insurance: If coverage provided to the additional insured is required by a contract or agreement, the most we will pay on behalf of the additional insured is the amount of insurance: 1.Required by the contract or agreement; or 2.Available under the applicable Limits of Insurance shown in the Declarations; whichever is less. This endorsement shall not increase the applicable Limits of Insurance shown in the Declarations. © Insurance Services Office, Inc., 2012 Change effective 09/18/2023 CG 20 10 04 13Page 2 of 2 10/02/2023A0112596 Middlesex Insurance Company Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B INSURED This endorsement changes the policy to which it is attached and is effective on the date issued unless otherwise stated. (The information below is required only when this endorsement is issued subsequent to preparation of the policy.) Endorsement Effective Policy No. Endorsement No. Insured Premium $ Insurance Company Countersigned By WSD 5025920 10 03/01/2024 INSURANCE COMPANY OF THE WEST SEASIDE HEATING & AIR INCL. WC 99 06 34 (Ed. 8-00) WORKERS COMPENSATION AND EMPLOYERS LIABILITY INSURANCE POLICY WC 99 06 34 (Ed. 8-00) WAIVER OF OUR RIGHT TO RECOVER FROM OTHERS ENDORSEMENT - BLANKET We have the right to recover our payments from anyone liable for an injury covered by this policy. We will not enforce our right against the person or organization named in the Schedule. (This agreement applies only to the extent that you perform work under a written contract that requires you to obtain this agreement from us). The additional premium for this endorsement shall be % of the total California Workers’ Compensation premium otherwise due. Schedule Person or Organization Job Description 2 ANY PERSON OR CALIFORNIA ORGANIZATION FOR OPERATIONS ONLY. WHOM THE NAMED INSURED IS REQUIRED UNDER WRITTEN CONTRACT TO FURNISH THIS WAIVER. Docusign Envelope ID: 7BCEC491-8DFB-4DEE-A0D4-94873DC7888B