HomeMy WebLinkAbout2342 LONGFELLOW RD; ; CBR2022-1645; PermitBuilding Permit Finaled
Residential Permit
Print Date: 07/19/2024
Job Address: 2342 LONGFELLOW RD,
Permit Type: BLDG-Residential
Parcel#: 2121424200
Valuation: $78,471.56
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Occupant Load:
Code Edition:
Sprinkled:
Project Title:
CARLSBAD, CA 92008-3829
Work Class:
Track#:
Lot#:
Project#:
Plan#:
Construction Type:
Orig. Plan Check#:
Plan Check#:
Addition
Description: REGER/MAEROWITZ: ADDITION (36 SF)/REMODEL (1556 SF)/PATIO (321 SF)
Applicant: Property Owner:
DEBORAH SHEWAGA
2600 ARGONAUTA ST
CARLSBAD, CA 92009-6501
CO-OWNERS PAMELA REGER AND TODD
MAEROWITZ
FEE
BUILDING PLAN CHECK
BUILDING PLAN CHECK
BUILDING PLAN CHECK FEE (manual)
2342 LONGFELLOW RD
CARLSBAD, CA 92008-3829
BUILDING PLAN REVIEW-MINOR PROJECTS (PLN)
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
PATIO-FRAME WITH COVER
SB1473 -GREEN BUILDING STATE STANDARDS FEE
SFD & DUPLEXES
STRONG MOTION -RESIDENTIAL (SMIP)
SWPPP IN SPECTION FEE TIER 1 -Medium BLDG
SWPPP PLAN REVIEW FEE TIER 1 -Medium
Total Fees: $3,315.53 Total Payments To Date: $3,315.53
{"cityof
Carlsbad
Permit No:
Status:
CBR2022-1645
Closed -Fina led
Applied: 05/11/2022
Issued: 12/12/2022
Finaled Close Out: 07/19/2024
Final Inspection: 06/27/2024
INSPECTOR: Alvarado, Tony
Contractor:
CHAPARRAL BU ILDERS LLC
3712 JETTY PT
CARLSBAD, CA 92010-5537
(760) 715-7740
Balance Due:
AMOUNT
$65.00
$755.30
$611.03
$98.00
$175.00
$100.00
$4.00
$1,162.00
$10.20
$271.00
$64.00
$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City M anager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Building Division Page 1 of 1
1635 Faraday Avenue, Ca rlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
( City of
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
8-1
Plan Check {!ft?U/l-2-/UJ'-{rs'
Est. Value J,Jt L//) I . ,,,,,..---
PC Deposit ff i 30
Date 5/~7-k:
Job Address 2342 LONGFELLOW RD, CARLSBAD, CA 92008
CT/Project#: TRACK NO 91-3 EVANS POINT, MAP 13189
Suite: APN: 212-142-42-00 ------
Lot#: 122 Year Built: 1999 ---------
Fire Sprinklers: C)vEs@ NO Air Condltloning:@YES Q NO
BRIEF DESCRIPTION OF WORK:
EI e ctr ic a I Panel Upgrade: QvEs® NO
SFD REMODEL AND ADDITION OF COVERED OUTDOOR PATIO
[ii Addltlon/New: _____ Living SF, 36 Deck SF, ___ Patio SF, 321 Garage SF __ _
Is this to create an Accessory Dwelling Unit? Ov 0 N New Fireplace? 0Y ON, if yes how many? ~
liJRemodel:_1_55_6 ___ .SF of affected area Is the area a conversion or change of use? 0v ON
0 Pool/Spa: ____ SF Additional Gas or Electrical Features? YES ------------
OSolar: ___ KW, ___ Modules, Mounted: 0Roof 0Ground, Tilt: 0 vO N, RMA: Ov ON,
Battery: Ov ON, Panel Upgrade: Ov ON
D Reroof: ----------------------------------11) Plumbing/Mechanical/Electrical
Ii] Only: Other:
13 S.F. OF GARAGE AREA CONVERTED TO LIVABLE AREA THIS IS INCLUDED IN ABOVE NUMBERS
This permit Is to be Issued in the name of the Property Owner as Owner-Builder, licensed contractor or Authorized A,ent of the
owner or contractor. The person listed as the Applicant below will be the main point of contact throughout the permit process.
PROPERTY OWNER
Name: Todd Maerowitz & Pamela Reger
Address: 2342 Longfellow Rd.
City: Carlsbad State: CA Zip: 92008
Phone: 760-271-1876
Email: deborah(@,sandieqoarchitects.com
DESIGN PROFESSIONAL
Name: Deborah Shewaga, Architect
Address: 2500 Argonauta St.
PRIMARY APPLICANT/ AUTHORIZED AGENT
Name: Deborah Shewaoa. Architect
Address: 2600 Argonauta St.
City: Carlsbad State: CA Zlp:_9_20_0_9 __ _
Phone: 760-560-6773
Email: deborah(@.sandieqoarchitects.com
CONTRACTOR OF RECORD
Name: T.B.D. 0°'0 f/N CL~!:, 1 N
City: Carlsbad State: CA Zip:_9_20_0_9 __
Address: ~ 7 / 2. Jr TTJL bf•
City: @ilUS(M h State: c5f Zip: q ZO ) 0
Phone: 7 b0 -71 ~-77L/O Phone: 760-560-6773
Email: deborah@sandiegoarchitects.com
Architect State License: C31 246 ----------
Email: ✓ f<..C ~ II @ OU rt OJ/'-. I C,J th
CA State License#: :3' 53J>J5 7 Class: Z3 • I
City Business License# (Required): 'f!ifU {)1 I ,9tq.., D~ v 2.~ 2. ?--
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
C/c~A-Aft-A I B(f;/tl~ 7 oV 7':3 REV. 08/20
IDENTIFY WHO WILL PERFORM THE WORK BY COMPLETING (OPTION A) OR (OPTION B) BELOW:
(OPTION A): LICENSED CONTRACTOR DECLARATION:
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code, and my license is in full force and effect. I also affirm under penalty of perjury one of the
following declarations:
l"xf1 have and will maintain a certificate of consent to self-Insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
~rk which this permit Is issued. Policy No. ______________________________________ _
DI have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensation insurance carrier and policy number are: Insurance Company Name: ____________________ _
Polley No. __________________________ Explratlon Date: ______________ _
D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person In any manner so as to become
subject to the workers' compensation Laws of California. WARNING: failure to seaire workers compensation coverace Is unlawful and shall subject an employer to
almlnal penalties and dvil fines up to $100,000.00, In addition the to the cost of compensation, damaces as provided for In Section 3706 of the Labor Code,
Interest and attorney's fees.
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there i a construction lending agency for the performance
lender's Name:_J-~~----------------
(OPTION B): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
DI, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who does such work
himself or through his own employees, provided that such improvements are not Intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
DI, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
DI am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
G0wner Builder acknowledgement and verification form# has been filled out, signed and attached to this application.
D Owners "Authorized Agent Form" has been filled out, signed and attached to this application giving the agent authority to obtain the permit on the owner's behalf
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the
improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed
contractors. I understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is
submitted or at the following Web site: http://www.leglnfo.ca.gov/calaw.html.
OWNER PRINT: __________ _ SIGN: __________ DATE: ______ _
APPLICANT CERTIFICATION: SIGNATURE REQUIRED AT THE TIME OF SUBMITTAL
By my signature below, I certify that: I am the property owner or State of California Licensed Contractor or authorized to act on the property
owner or contractor's behalf. I certify that I have read the application and state that the above information Is correct and that the information on
the plans Is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for Inspection purposes. I ALSO AGREE TO SAVE,
INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL UABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE
AGAINST SAID QTY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit Is required for excavations over 5'0' deep and
demolition or construction of structures aver 3 stories in height.
APPLICANT PRINT: Deborah Shewaga SIGN: ! ,, ,.11//Mci DATE: 5/5/22 ------------------------
1635 Faraday Ave carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
2 REV. 08/20
( Cicyof
Carlsbad
OWNERS
AUTHORIZED
AGENT FORM
B-62
Development Services
Building Division
1635 Faraday Avenue
76Q-602-2719
www .carlsbadca.gov
OWNER'SAUTHORIZED AGENT FORM
Only a property owner, contractor or their authorized agent may submit plans and applications for building
permits. To authorize a thlrd~party agent to sign for a building permit, the owner's third party agent must bring
this signed form, which identifies the agent and the owner who s/he is representing, and for what jobs s/he
may obtain permits. The form must be completed In Its entirety to be accepted by the City for each separate
permit application.
Note: The following Owner's Authorized Agent form Is required to be completed by the
property owner only when designating on agent to apply for o construction permit
on his/her behalf.
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Property Owner Acknowledgement, the execution of which I understand is my personal responsibility,
I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and flle the documents necessary
to obtain an Owner-Builder Permit for my project.
. Residential Remodel/Addition Scope of Construction Project (or Description of Work): __________________ _
Project Location or Address: 2342 Longfellow Rd ., Carlsbad, CA 92008
Name of Authorized Agent: Deborah Shewaga 760-560-6773 Tel No. ________ _
AddressofAuthorizedAgent:2600 Argonauta St. Carlsbad, CA 92009
i declare under penalty of perjury that I am the property owner for the address listed above and I personally filled
out the above information and certify its accuracy.
Property Owner's Signature: Date: l/)29/:W, 2
Building Permit Inspection History Finaled
{city of
Carlsbad
PERMIT INSPECTION HISTORY for (CBR2022-1645)
Permit Type: BLDG-Residential Application Date: 05/11/2022 Owner: CO-OWNERS PAMELA REGER AND
TODD MAEROWITZ
Work Class: Addition Issue Date: 12/12/2022 Subdivision: CARLSBAD TCT#91-03
Status: Closed -Finaled Expiration Date: 05/20/2024 Address: 2342 LONGFELLOW RD
CARLSBAD, CA 92008-3829 IVR Number: 40586
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection
Date Start Date Status
01/24/2023 01/24/2023 BLDG-11 201327 -2023 Partial Pass Tony Alvarado Reinspection
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency January 24, 2023: Yes
1. (Two)interior retrofit engineered footings
and (two) exterior patio structure footings,
and (one) exterior foundation slab footing
for new/altered fireplace slab on grade
foundation systems, scope of work per
engineered plans and detail
specifications-approved.
03/29/2023 03/29/2023 BLDG-18 Exterior 206509-2023 Passed Tony Alvarado
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
NOTES Created By TEXT Created Date
Angie Teanio 760-715-7740 John 03/28/2023
05/31/2023 05/31/2023 BLDG-24 Rough/Topout 212518-2023 Cancelled Tony Alvarado Reinspectlon
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Cancelled per owner representative John No
Clasen.
NOTES Created By TEXT Created Date
Angie Teanio 760-715-7740 John 05/30/2023
BLDG-34 Rough 212517-2023 Cancelled Tony Alvarado Reinspection
Electrical
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Cancelled per owner representative John No
Clasen.
NOTES Created By TEXT Created Date
Angie Teanio 760-715-7740 John 05/30/2023
06/01/2023 06/01/2023 BLDG-24 Rough/Topout 212840-2023 Partial Pass Tony Alvarado Reinspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Friday, July 19, 2024
Inspection
Incomplete
Complete
Incomplete
Incomplete
Incomplete
Page 1 of 9
PERMIT INSPECTION HISTORY for (CBR2022-1645)
Permit Type: BLDG-Residential Application Date: 05/11/2022 Owner: CO-OWNERS PAMELA REGER AND
TODD MAEROWITZ
Work Class: Addition Issue Date: 12/12/2022 Subdivision: CARLSBAD TCT#91-03
Status:
Scheduled
Date
Closed -Finaled Expiration Date: 05/20/2024
IVR Number: 40586
Address: 2342 LONGFELLOW RD
CARLSBAD, CA 92008-3829
Actual Inspection Type
Start Date
Inspection No.
NOTES Created By
Angie Teanio
Angie Teanio
BLDG-34 Rough
Electrical
212839-2023
NOTES Created By
Angie Teanio
Angie Teanio
Inspection Primary Inspector
Status
TEXT
760-715-7740 John
760-715-7740 John
Partial Pass Tony Alvarado
TEXT
760-715-7740 John
760-715-7740 John
BLDG-SW-Inspection
Checklist Item
213036-2023
COMMENTS
Partial Pass Tony Alvarado
Are inactives slopes properly
stabilized?
Are areas flatter than 3:1
covered or protected?
Are sediment controls properly
maintained?
Are erosion control BMPs
functioning properly?
Are natural areas protected
from erosion?
Are perimeter control BMPs
maintained?
Is the entrance stabilized to
prevent tracking?
Have sediments been tracked
on to the street?
Have materials collected
around the storm drains?
Has sediment accumulated on
impervious surfaces?
Are dumpsters and trash
receptacles covered?
Has trash/debris accumulated
throughout the site?
Are stockpiles and spoils
protected from runoff?
Are all storage areas clean
and maintained?
Were spills/leaks observed
during the inspection?
Were there any discharges
during the inspection?
Reinspection Inspection
Created Date
05/30/2023
05/31/2023
Reinspection Incomplete
Created Date
05/30/2023
05/31/2023
Reinspection Incomplete
Passed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Friday, July 19, 2024 Page 2 of 9
PERMIT INSPECTION HISTORY for {CBR2022-1645)
Permit Type: BLDG-Residential Application Date: 05/11/2022 Owner: CO-OWNERS PAMELA REGER AND
TODD MAEROWITZ
Work Class: Addition Issue Date: 12/12/2022 Subdivision: CARLSBAD TCT#91-03
Status:
Scheduled
Date
06/02/2023
Closed -Finaled Expiration Date: 05/20/2024
IVR Number: 40586
Address: 2342 LONGFELLOW RD
CARLSBAD, CA 92008-3829
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector
06/02/2023 BLDG-23 213099-2023 Partial Pass Tony Alvarado
Gas/Test/Repairs
Checklist Item
BLDG-Building Deficiency
COMMENTS
1. Rough electrical, plumbing, gas line
under pressure test, elevator shaft drywall
nailing, rough combination inspection for
new 3/4"inch 3,000 lb. steel I-beam with 6"
x 6" tube steel flag poles, welded
connections top and bottom, per structural
plan -partial pass.
2. Acquired weld certification
letter-pending.
BLDG-24 Rough/Topout 213089-2023 Partial Pass Tony Alvarado
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Angie Teanio
Angie Teanio
COMMENTS
1. Rough electrical, plumbing, gas line
under pressure test, elevator shaft drywall
nailing, rough combination inspection for
new 3/4"inch 3,000 lb. steel I-beam with 6"
x 6" tube steel flag poles, welded
connections top and bottom, per structural
plan -partial pass.
2. Acquired weld certification
letter-pending.
TEXT
760-715-7740 John
760-715-7740 John
BLDG-34 Rough
Electrical
213090-2023 Partial Pass Tony Alvarado
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Angie Teanio
Angie Teanio
COMMENTS
1. Rough electrical, plumbing, gas line
under pressure test, elevator shaft drywall
nailing, rough combination inspection for
new 3/4"inch 3,000 lb. steel I-beam with 6"
x 6" tube steel flag poles, welded
connections top and bottom, per structural
plan -partial pass.
2. Acquired weld certification
letter-pending.
TEXT
760-715-7740 John
760-715-7740 John
BLDG-84 Rough
Combo(14,24,34,44)
213100-2023 Partial Pass Tony Alvarado
Reinspection Inspection
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Created Date
05/30/2023
05/31/2023
Reinspection Incomplete
Passed
Yes
Created Date
05/30/2023
05/31/2023
Reinspection Incomplete
Friday, July 19, 2024 Page 3 of 9
PERMIT INSPECTION HISTORY for (CBR2022-1645)
Permit Type: BLDG-Residential Application Date: 05/11/2022 Owner: CO-OWNERS PAMELA REGER AND
Work Class: Addition
Status: Closed -Finaled
TODD MAEROWITZ
Issue Date: 12/12/2022 Subdivision: CARLSBAD TCT#91-03
Expiration Date: 05/20/2024
IVR Number: 40586
Address: 2342 LONGFELLOW RD
CARLSBAD, CA 92008-3829
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection Primary Inspector Reinspection Inspection
06/06/2023
Checklist Item
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
Status
COMMENTS
1. Rough electrical, plumbing, gas line
under pressure test, elevator shaft drywall
nailing, rough combination inspection for
new 3/4"inch 3,000 lb. steel I-beam with 6"
x 6" tube steel flag poles, welded
connections top and bottom, per structural
plan -partial pass.
2. Acquired weld certification
letter-pending.
BLDG-SW-Inspection
Checklist Item
213101-2023
COMMENTS
Partial Pass Tony Alvarado
Are inactives slopes properly
stabilized?
Are sediment controls properly
maintained?
Are natural areas protected
from erosion?
Is the entrance stabilized to
prevent tracking?
Have sediments been tracked
on to the street?
Have materials collected
around the storm drains?
Has sediment accumulated on
impervious surfaces?
Are dumpsters and trash
receptacles covered?
Has trash/debris accumulated
throughout the site?
Are stockpiles and spoils
protected from runoff?
Are all storage areas clean
and maintained?
Were spills/leaks observed
during the inspection?
Were there any discharges
during the inspection?
06/06/2023 BLDG-16 Insulation
Checklist Item
213369-2023
COMMENTS
Passed Tony Alvarado
BLDG-Building Deficiency June 6, 2023:
1. Energy efficient, thermal insulation
(typical throughout) -approved.
Friday, July 19, 2024
Passed
Yes
Yes
Yes
Yes
Reinspection Incomplete
Passed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Complete
Passed
Yes
Page 4 of 9
PERMIT INSPECTION HISTORY for (CBR2022-1645)
Permit Type: BLDG-Residential Application Date: 05/11/2022 Owner: CO-OWNERS PAMELA REGER AND
TODD MAEROWITZ
Work Class: Addition Issue Date: 12/12/2022 Subdivision: CARLSBAD TCT#91-03
Status: Closed -Finaled Expiration Date: 05/20/2024 Address: 2342 LONGFELLOW RD
CARLSBAD, CA 92008-3829 IVR Number: 40586
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector
Date Start Date
Friday, July 19, 2024
Status
BLDG-84 Rough
Combo(14,24,34,44)
213264-2023 Passed Tony Alvarado
Checklist Item
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
NOTES Created By
Angie Teanio
COMMENTS
June 6, 2023:
1. Rough electrical, plumbing, gas line
under pressure test, elevator shaft drywall
nailing. rough combination inspection for
new 3/4"inch 3.000 lb. steel I-beam with 6"
x 6" tube steel flag poles, welded
connections top and bottom, per structural
plan -partial pass.
2. All minor corrections lists, straps, and
(Dottie)-metal nail plates (typical)-approved
throughout residential-alterations/remodel,
scope of work-approved.
3. Acquired weld certification letter-still
pending.
TEXT
760-715-77 40 John
BLDG-SW-Inspection 213370-2023 Partial Pass Tony Alvarado
Reinspection Inspection
Passed
Yes
Yes
Yes
Yes
Created Date
06/05/2023
Complete
Reinspection Incomplete
Page 5 of 9
PERMIT INSPECTION HISTORY for {CBR2022-1645)
Permit Type: BLDG-Residential Application Date: 05/11/2022 Owner: CO-OWNERS PAMELA REGER AND
TODD MAEROWITZ
Work Class: Addition Issue Date: 12/12/2022 Subdivision: CARLSBAD TCT#91 -03
Status:
Scheduled
Date
06/30/2023
11/21/2023
Closed -Finaled Expiration Date: 05/20/2024
40586
Address: 2342 LONGFELLOW RD
CARLSBAD, CA 92008-3829
IVR Number:
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector
Checklist Item
Are inactives slopes properly
stabilized?
Are sediment controls properly
maintained?
Are natural areas protected
from erosion?
Is the entrance stabilized to
prevent tracking?
Have sediments been tracked
on to the street?
Have materials collected
around the storm drains?
Has sediment accumulated on
impervious surfaces?
Are dumpsters and trash
receptacles covered?
Has trash/debris accumulated
throughout the site?
Are stockpiles and spoils
protected from runoff?
Are all storage areas clean
and maintained?
Were spills/leaks observed
during the inspection?
Were there any discharges
during the inspection?
COMMENTS
06/30/2023 BLDG-17 Interior
Lath/Drywall
216107-2023 Passed Tony Alvarado
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Angie Teanio
COMMENTS
Gypsum board/drywall at all remodel
locations. kitchen, and bathroom locations,
also includes moisture resistive drywall
membrane product -approved.
TEXT
760-715-77 40 John
11/21/2023 BLDG-14 231119-2023 Partial Pass Tony Alvarado
Frame/Steel/Bolting/We
lding (Decks)
Reinspection Inspection
Passed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Passed
Yes
Created Date
06/29/2023
Complete
Reinspection Incomplete
Friday, July 19, 2024 Page 6 of 9
PERMIT INSPECTION HISTORY for (CBR2022-1645)
Permit Type: BLDG-Residential
Work Class: Addition
Status:
Scheduled
Date
Closed -Finaled
Actual Inspection Type
Start Date
Checklist Item
Application Date: 05/1 1/2022 Owner: CO-OWNERS PAMELA REGER AND
TODD MAEROWITZ
Issue Date: 12/12/2022 Subdivision: CARLSBAD TCT#91-03
Expiration Date: 05/20/2024
IVR Number:
Inspection No.
COMMENTS
40586
Inspection
Status
Address: 2342 LONGFELLOW RD
CARLSBAD, CA 92008-3829
Primary Inspector Reinspection Inspection
Passed
BLDG-Building Deficiency 1. Exterior, attached, gable, roof,
structural, steel and wood frame, Gabel
roof patio structure, per engineer, plans,
and detail specification -partial pass.
Yes
Friday, July 19, 2024
BLDG-15 Roof/ReRoof
(Patio)
Checklist Item
2. PENDING:
A) A-35 metal seismic connector missing
at perimeter to buy freeze block.
Connection to header beam -not installed
-failed.
B) informed contractor, representative,
letter from structural engineer, not requiring
A-35 metal connector clips, or letter,
indicating A-35 metal connector clips are
not required.
3. The rest of patio framing, scope of
work, per engineered , plans, and detail
specifications -OK.
231120-2023 Passed Tony Alvarado
COMMENTS
BLDG-Building Deficiency November 21 , 2023:
BLDG-SW-Inspection
1. Roof nailing for attached, gable, roof,
engineered patio structure with metal, ST
strap, connectors, located at Ridge and
rafter connection -approved.
231300-2023 Partial Pass Tony Alvarado
Complete
Passed
Yes
Reinspection Incomplete
Page 7 of 9
PERMIT INSPECTION HISTORY for (CBR2022-1645)
Permit Type: BLDG-Residential Application Date: 05/11/2022 Owner: CO-OWNERS PAMELA REGER AND
TODD MAEROWITZ
Work Class: Addition Issue Date: 12/12/2022 Subdivision: CARLSBAD TCT#91-03
Status: Closed -Finaled Expiration Date: 05/20/2024 Address: 2342 LONGFELLOW RD
IVR Number: 40586 CARLSBAD, CA 92008-3829
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
Are inactives slopes properly Yes
stabilized?
Are sediment controls properly Yes
maintained?
Are natural areas protected Yes
from erosion?
Is the entrance stabilized to Yes
prevent tracking?
Have sediments been tracked Yes
on to the street?
Have materials collected Yes
around the storm drains?
Has sediment accumulated on Yes
impervious surfaces?
Are dumpsters and trash Yes
receptacles covered?
Has trash/debris accumulated Yes
throughout the site?
Are stockpiles and spoils Yes
protected from runoff?
Are all storage areas clean Yes
and maintained?
Were spills/leaks observed Yes
during the inspection?
Were there any discharges Yes
during the inspection?
06/27/2024 06/27/2024 BLDG-Final Inspection 253208-2024 Passed Tony Alvarado Complete
Checklist Item COMMENTS Passed
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
BLDG-SW-Inspection 253265-2024 Passed Tony Alvarado Complete
Friday, July 19, 2024 Page 8 of 9
PERMIT INSPECTION HISTORY for (CBR2022-1645)
Permit Type: BLDG-Residential Application Date: 05/11/2022 Owner: CO-OWNERS PAMELA REGER AND
TODD MAEROWITZ
Work Class: Addition Issue Date: 12/12/2022 Subdivision: CARLSBAD TCT#91-03
Status: Closed -Finaled Expiration Date: 05/20/2024 Address: 2342 LONGFELLOW RD
CARLSBAD, CA 92008-3829
Scheduled
Date
IVR Number:
Actual Inspection Type
Start Date
Inspection No.
Checklist Item
Are inactives slopes properly
stabilized?
Are sediment controls properly
maintained?
Are natural areas protected
from erosion?
Is the entrance stabilized to
prevent tracking?
Have sediments been tracked
on to the street?
Have materials collected
around the storm drains?
Has sediment accumulated on
impervious surfaces?
Are dumpsters and trash
receptacles covered?
Has trash/debris accumulated
throughout the site?
Are stockpiles and spoils
protected from runoff?
Are all storage areas clean
and maintained?
Were spills/leaks observed
during the inspection?
Were there any discharges
during the inspection?
COMMENTS
Friday, July 19, 2024
40586
Inspection
Status
Primary Inspector Reinspection Inspection
Passed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Page 9 of 9
( City of
Carlsbad
SPECIAL INSPECTION
AGREEMENT
B~45
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed
requires special inspection, structural observation and construction material testing.
ProjecUPermit: CB-CBR2022-1645 Project Address: 2342 LONGFELLOW RD
A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder
0 . (If you checked as owner-builder you must also complete Section 8 of this agreement.}
Name: (Please prlntJodd Maerowitz
(Firsl) (M l.) (Last)
Mailing Address: 2342 Longfellow R_d_,_C_a_rl_s_ba_d_,_C_A_92_0_0_8 _________________ _
Email· todd@todd m aerowitz.com Phone: 760-271-1876 _
I am: iiiiilProperty Owner □Property Owner's Agent of Record □Architect of Record □Engineer of Record
State of California Registration Numbe • _______ Expiration Date: ________ _
AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read ,
understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural
observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of
special inspections noted on the approved plans and, as required by the California Building Code.
Signature· C./. Date: 6/9/22 _ __ __ __ _
B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the
contractor I builder/ owner-builder.
Contractor's Company Name: _ _ ________ Please check if you are Owner-Builder 0
Name: (Please print) _
(Fir,,t) (M l) (Last)
Mailing Address: ___________________________________ _
Email: _________________________ Phone: ____ _
State of California Contractor's License Number: ______ _ Expiration Date: _______ _
• I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on
the approved plans:
• I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the
building official;
• I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and
frequency of reporting and the distribution of the reports; and
• I certify that I will have a qualified person within our (the contractor's) organization to exercise such control.
• I will provide a final report I letter in compliance with CBC Section 1704.1.2 prior to requesting final
inspection.
Signature:,... _______________ _ _______ Date: ___________ _
B-45 Page 1 of 1 Rev. 03/20
David Thomas
Engineering, A.P .C.
Structural Engineering Services
Structural Calculations
(Remodel to Existing 2-Story SFR)
Project
REGER/MAEROWITZ Residence/ 22124
2 342 Longfellow Road
San Diego, California 92008
Prepared For
Deborah Shewaga
Ideal Design Systems,lnc.
2600 Argonauta Street
Carlsbad, California 92008
4-25-2022
ITY
Mailing: 3525 Del Mar I-Ieights Road, #331, San Diego, California 92130
Physical: 12625 High Bluff Drive, Suite 302, San Diego, California 92130
Office Phone: (858) 201 -3072 Cell Phone: (858) 336-9902
Website: www.dtengsd.com Email: david@dtengsd.com
.. I Job Reger-Maerowitz Residence 22124
I ,
/D \ ' \ C .... , ... ,, ........ )
Calculated by __ --=D-"--T-Date ____ _
David Thomas Engineering
TABLE OF CONTENTS
1.. PROJECT SCOPE / DESIGN CRITERIA. ............................................................................................................ ..
2.. DESIGN LOADS ....................................................................................................................................................................... ..
3. VERTICAL ANALYSIS:
PAGE
2
3
A. HORIZONTAL MEMBER DESIGN (BEAMS, HEADERS, JOISTS, ETC .. )........ 4-18
B. VERTICAL MEMBER DESIGN (COLUMNS, STUDS, ETC.) ......................................... __ _
4.. LATERAL ANALYSIS:
A. SEISMIC/WIND LOADING ANALYSIS & LATERAL DISTRIBUTION..................... 19-20
B.. LATERAL LOAD-RESISTING DESIGN:
I. SHEARWALL DESIGN.......................................................................................................................... 21-23
II. CANTILEVERED STEEL COLUMN ELEMENTS....................................................... 24-26
Ill. STEEL MOMENT FRAMES ...................................................................................................... .
IV. ________ .................................................................................................... ..
5.. FOUNDATION DESIGN:
A. CONTINUOUS & SPREAD FOOTINGS ............................................................................................... __ _
B.. RETAINING WALLS .................................................................................................................................... __ _
C.. CONCRETE GRADE BEAMS ......................................................................................................................... ·------==--
D.. DEEPENED CONCRETE PIERS/CAISSONS ................................................................................... ---=2:..:..7 __
E.. ______________ .................................................................................... __ _
6.. SCHEDULES:
A. SHEARWALL SCHEDULE...................................................................................................................................... 28
B.. HOLD DOWN SCHEDULE........................................................................................................................ 29
C.. SPREAD FOOTING SCHEDULE .. .. .... .. .. .. . .... . . . . .. . .. .... .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . .. .. .. .. .. .. . . .. . .. .. . .... .. ... 30
I of 30
~I L~
Job Reger-Maerowitz Residence 22124
Calculated by __ _____,D"""T~ Date ____ _
David Thomas Engineering
PROJECT SCOPE
Provide vertical and lateral load calculations for a proposed Remodel to existing 2-story single family-residence
at 2342 Longfellow Road, Carlsbad, California 92008. Residence to be constructed utilizing primarily wood-
frame construction. Roof framing to consist of a combination of conventional stick-frame and prefabricated wood
roof trusses (designed by other), and the foundation system to consist of a Post Tensioned slab & conventional
slab-on-grade with deepened perimeter footings. A soils report was not provided for this project. Therefore, the
foundation design will be based on the minimum soil bearing capacity as specified in the current version of the
Governing Code -2019 California Building Code. David Thomas Engineering makes no representations
concerning the suitability of the soils and/or minimum soil values allowed by the CBC.
These calculations have been prepared for the exclusive use of Todd Maerowitz & Pamela Reger and
their design consultants for the specific site listed above. Should modifications be made to the project
subsequent to the preparation of these calculations, David Thomas Engineering should be notified to review
the modifications with respect to the recommendations/conclusions provided herein, to determine if any
additional calculations and/or recommendations are necessary. Our professional services have been
performed, our findings obtained, and our recommendations prepared in accordance with generally
accepted engineering principles and practices.
GOVERNING CODE:
CONCRETE:
MASONRY:
REINFORCING STEEL:
STRUCTURAL STEEL:
SAWN LUMBER:
E.W.P.:
GLULAMS:
SOIL:
DESIGN CRITERIA SUMMARY
2019 C.B.C.
f c = 2500 PSI (MIN.), NO SPECIAL INSPECTION REQ'D, (U.N.O.)
ASTM C90, f'm = 1500 PSI, SPECIAL INSPECTION REQ'D, (U.N.O.)
ASTM A615, Fy = 60 KSI FOR #4 AND LARGER (U.N.O.)
ASTM A992, Fy = 50 KSI (ALL 'W' SHAPES, ONLY)
ASTM A36, Fy = 36 KSI (STRUCTURAL PLATES, ANGLES, CHANNELS)
ASTM A500, GRADE B, Fy = 46 KSI (STRUCTURAL TUBES-HSS)
ASTM A53, GRADE B, Fy = 35 KSI (STRUCTURAL PIPES)
DOUG FIR LARCH, ALLOWABLE UNIT STRESSES PER 2018 NDS.
BOISE-CASCADE: BCI-JOIST (ICC-ESR-1336), VERSA-LAM (ICC-ESR-1 040)
DOUGLAS FIR OR DOUGLAS FIR/HEM
GRADE 24F-V4 (SIMPLE SPANS) GRADE 24F-V8 (CANTILEVERS)
EXISTING NATURAL SOIL VALUES PER CBC TABLE 1806.2 (1,500 PSF)
2 of 30
I\ I •
Job Reger-Maerowitz Residence 22124
;E \ I \ ...................... )
Calculated by __ _.__F...,R_ Date ____ _
David Thomas Engineering
DESIGN LOADS
CASE 1 CASE II
MATERIAL: -'-Tl=LE=-----
ROOF SLOPE: PITCHED
WATERPROOF
FLAT
DEAD LOAD:
ROOFING MATERIAL ............................................................................ .
SHEATHING ................................................................................................. .
RAFTERS/C.J. (or) TRUSSES ........................................................................ .
INSULATION ................................................................................................... .
DRYWALL ......................................................................................................... .
OTHER (ELEC., MECH., MISC.) ..................................................................... .
TOT AL DEAD LOAD:
LIVE LOAD:
TOTAL LOAD:
15.0 PSF
1.5
4.0
1.5
2.5
0.5
25.0 PSF
20.0 PSF
45.0 PSF
FLOOR
FLOOR MATERIAL: -----'T'""'IL=E=------
DEAD LOAD:
10 PSF
1.5
4.0
1.5
2.5
0.5
20.0 PSF
20.0 PSF
40.0 PSF
DECK
TILE
FLOORING FINISH ........................................................................................ . 19.0 PSF 19.0 PSF
LT. WEIGHT CONCRETE (_in.) ................................................................. .
SHEATHING .................................................................................................... .
JOISTS ............................................................................................................. .
DRYWALL ........................................................................................................ .
OTHER (ELEC., MECH., MISC.) .......................................................................... .
TOT AL DEAD LOAD:
LIVE LOAD:
TOTAL LOAD:
2.0
3.5
2.5
3.0
30.0 PSF
40.0 PSF
70.0 PSF
EXTERIOR WALL FINISH: STUCCO
2.0
3.5
2.5
3.0
30.0 PSF
60.0 PSF
90 .0 PSF
STUDS ........... ................................................. ........................................... ....... 1.0 PSF 1.0 PSF
DRYWALL ...... .............................................. ................. ............................. ..... 2.5 2.5
I NS ULA TION .. . .. .. . .. .. . .. .. .. ... .. . . . .. . .. ... .. ....... .. . .. . .. .. .. . . ... .. . .. . . . .. . .. .. .. ........ .. .. . . . ... .. .. . . 1.5 1.5
EXTERIOR FINISH ............................................................................................ 10.0 .0
OTHER ................................................................................................................. _il ---1.,Q
TOTAL LOAD: 16.0 PSF .0 PSF
INTERIOR WALL
STUDS .................................................................................................................................. .
DRYWALL ........................................................................................................................... .
OTHER ...................................................................................................................................... .
TOTAL LOAD:
1.0 PSF
5.0
1.0
7.0 PSF
3 of 30
i \ ' \ I \ • I D \ '···-···· .. ···········i
DAVID THOMAS ENGINEERING,APC
, Structural Engineering Services
/ \ Office: (858) 201-3072
I E \ Cell: (858) 336-9902
c.~.""··'~' david@dtengsd.com
Wood Beam
Project Title:
Engineer:
Project ID:
Project Descr:
Reger/Maerowitz Residence
David Thomas, SE
21124
Project File: Reger-Maerowitz Residence.ec6
UC#: KW-06015405, Build:20.22.3.31
DESCRIPTION: RR-1
DAVID THOMAS ENGINEERING, A.P.C. (c) ENERCALC INC 1983-2022
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
Analysis Method : Allowable Stress Design
Load Combination : ASCE 7-16
Wood Species
Wood Grade
Beam Bracing
Douglas Fir -Larch
No.2
Completely Unbraced
Fb +
Fb -
Fe -Prll
Fe -Perp
Fv
Ft
900 psi
900 psi
1350 psi
625psi
180 psi
575 psi
E : Modulus of Elasticity
Ebend-xx 1600ksi
Eminbend-xx 580ksi
Density 31.21 pcf
,:----------------.---------__::cD:,.::0.:..:.0=5 _9L""r 0.:.:·.::.04.:.,_ ________ ~----------~
4x8
Span = 11.0 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loading
Uniform Load : D = 0.0250, Lr = 0.020 ksf, Tributary Width = 2.0 ft, (W1, ROOF)
DESIGN SUMMARY Design OK
Maximum Bending Stress Ratio = 0.395 1 Maximum Shear Stress Ratio = 0.123 : 1
Section used for this span 4x8 Section used for this span 4x8
fb: Actual = 565.31 psi fv: Actual = 27.65 psi
Fb: Allowable = 1 ,432.41 psi Fv: Allowable = 225.00 psi
Load Combination +D+Lr Load Combination +D+Lr
Location of maximum on span = 5.500ft Location of maximum on span = 10.398 ft
Span # where maximum occurs = Span# 1 Span # where maximum occurs = Span# 1
Maximum Deflection
Max Downward Transient Deflection 0.075 in Ratio= 1771 >=360 Span: 1 : Lr Only
Max Upward Transient Deflection 0 in Ratio= 0 <360 n/a
Max Downward Total Deflection 0.178in Ratio = 741 >=240 Span: 1 : +D+Lr
Max Upward Total Deflection O in Ratio= 0 <240 n/a
Maximum Forces & Stresses for Load Combinations
Load Combination Max S!ress Ra!tos Momeni Values Sfiear Values
Segment Length Span# M V Cd CFN Ci Cr Cm Ct CL M fb F'b V fv F'v
DOnly 0.00 0.00 0.00 0.00
Length = 11 .0 ft 1 0.316 0.099 0.90 1.300 1.00 1.00 1.00 1.00 0.99 0.84 328.53 1038.81 0.27 16.07 162.00
+D+Lr 1.300 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00
Length = 11.0 fl 0.395 0.123 1.25 1.300 1.00 1.00 1.00 1.00 0.98 1.44 565.31 1432.41 0.47 27.65 225.00
+D+0.750Lr 1.300 1.00 1.00 1.00 1.00 0.98 0.00 0.00 0.00 0.00
Length = 11.0 ft 0.353 0.110 1.25 1.300 1.00 1.00 1.00 1.00 0.98 1.29 506.11 1432.41 0.42 24.75 225.00
+0.60D 1.300 1.00 1.00 1.00 1.00 0.98 0.00 0.00 0.00 0.00
Length = 11 .0 ft 1 0.108 0.033 1.60 1.300 1.00 1.00 1.00 1.00 0.97 0.50 197.12 1817.40 0.16 9.64 288.00
Overall Maximum Deflections
Load Combination Span Max.·-· Defl Location in Span Load Combination Max.•+· Defl Location in Span
+D+Lr 1 0.1779 5.540 0.0000 0.000
4 of 30
DAVID THOMAS ENGINEERING,APC Project Title: i . Structural Engineering Services
/ \ Office: (858) 201-3072
I E \ Cell: (858) 336-9902
L,,=,.,ccc> david@dtengsd.com
Wood Beam
UC#: KW-06015405, Build:20.22.3.31
DESCRIPTION: RR-1
Engineer:
Project ID:
Project Descr:
DAVID THOMAS ENGINEERING, A.P.C.
Reger/Maerowitz Residence
David Thomas, SE
21 124
Project File: Reger-Maerowitz Residence.ec6
(c) ENERCALC INC 1983-2022
Vertical Reactions Sup port notation : Far left is # 1 Values in KIPS
Load Combination
Overall MAXimum
Overall MINimum
DOnly
+D+Lr
+D+0.750Lr
+0.60D
Lr Only
Support 1 Support 2
0.525 0.525
0.220 0.220
0.305 0.305
0.525 0.525
0.470 0.470
0.183 0.183
0.220 0.220
5 of 30
Job Re2er/Maerovitz Residence 21124
Calculated by _..,.._..,D,.._.T_ Date __ _
David Thomas Engineering
DESIGN 'LEVEL: 2.~,) -----------
Beam Design
LABEL: f B -J · SPAN= ,~ FT .
. W1 = ?v fSf (tf) "::: ?'° pLf
W2= l 71
ALT: _____ GRADE: ___ C: __ E= _____ ksl
LABEL: fJ:::'k: SPAN= '1,,,1,_,, FT.
W2= •
P1 = [.r!3-! I 121, 1 ~ 4-,•7~ ~
• ALT: _____ GRADE: ___ C: --,---E= ___ ksl
~ ' , ' ~· . j• • I I ' •
w,, .Wt.-· :.· . ,;
'Jl'o----11
P1 = ~ • -~ , -·
P2 = • -• • : -• '✓ • -• • ;· 4 .
~ =-1>~~t~ '1~ rtr
USE: 4 X 11 9 t/'4~ •. GRADE: ,31@
ALT: ____ ____,GRADE: ___ C: __
~ ' ...... ,
' ,, '~
r4, F3
C: -Rt :a~;;.ft~j_ lbs .• Ra.-·[~ 1 lt:,j:° . Jbs .
E= ___ ·ksl i ,;:a:3i1-zo: Us
~.' .· .. .._,:,J' <.~:,:. , ,r
iJt == I<,, fi-r 'r__,:1·;: 166 ~ :~~,-~ 6 of 30
DAVID THOMAS ENGINEERING,APC
/, Structural Engineering Services
/ \ Office: (858) 201-3072
Project Title:
Engineer:
Reger/Maerowitz Residence
David Thomas, SE
I E \ Cell: (858) 336-9902
c__,, __ ,, ____ ) david@dtengsd.com
Project ID:
Project Descr:
22124
Wood Beam Project File: Reger-Maerowitz Residence.ec6
LIC#: KW-06015405, Build:20.22.3.31
DESCRIPTION: FB-1
CODE REFERENCES
DAVID THOMAS ENGINEERING, A.P.C.
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set: ASCE 7-16
Material Properties
(c) ENERCALC INC 1983-2022
Analysis Method : Allowable Stress Design
Load Combination : ASCE 7-16
Fb +
Fb -
2,400.0 psi
1,850.0psi
1,650.0 psi
E : Modulus of Elasticity
Wood Species
Wood Grade
Beam Bracing
OF/OF
24F -V4
Completely Unbraced
········ ..... -------------------
Fe -Prll
Fe -Perp
Fv
Ft
D 0.385 Lr 0.22
8.75x12
650.0 psi
265.0psi
1,100.0 psi
Ebend-xx 1,800.0ksi
Eminbend -xx 950.0 ksi
Ebend-yy 1,600.0 ksi
Eminbend -yy 850.0ksi
Density 31.210pcf
Span= 15.0 ft
-------------1
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loading
Uniform Load : D = 0.0350, Lr= 0.020 ksf, Tributary Width = 11 .0 ft, (W1, ROOF)
DESIGN SUMMARY Design OK
Maximum Bending Stress Ratio = 0.343 1 Maximum Shear Stress Ratio = 0.176 : 1
Section used for this span 8.75x12 Section used for this span 8.75x12
fb: Actual = 1,008.90psi fv: Actual = 58.42 psi
Fb: Allowable = 2,941 . 05 psi Fv: Allowable = 331.25 psi
Load Combination +D+Lr Load Combination +D+Lr
Location of maximum on span = 7.500ft Location of maximum on span = 14.015ft
Span# where maximum occurs = Span# 1 Span # where maximum occurs = Span# 1
Maximum Deflection
Max Downward Transient Deflection 0.111 in Ratio= 1619 >=360 Span: 1 : Lr Only
Max Upward Transient Deflection 0 in Ratio= 0<360 n/a
Max Downward Total Deflection 0.317 in Ratio= 567 >=180 Span: 1 : +D+Lr
Max Upward Total Deflection O in Ratio= 0<180 n/a
Maximum Forces & Stresses for Load Combinations
Load Combination Max S{ress Raf,os Momenf 'ilalues Sfiear 'ilalues
Segment Length Span# M V Cd CFN C; Cr Cm Ct CL M fb F'b V fv F'v
DOnly 0.00 0.00 0.00 0.00
Length = 15.0 fl 1 0.309 0.159 0.90 0.980 1.00 1.00 1.00 1.00 0.99 11.47 655.32 2117.56 2.66 37.95 238.50
+D+Lr 0.980 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00
Length = 15.0 ft 1 0.343 0.176 1.25 0.980 1.00 1.00 1.00 1.00 0.99 17.66 1,008.90 2941 .05 4.09 58.42 331 .25
+D+0.750Lr 0.980 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00
Length = 15.0 fl 0.313 0.161 1.25 0.980 1.00 1.00 1.00 1.00 0.99 16.11 920.50 2941 .05 3.73 53.30 331.25
+0.600 0.980 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00
Length= 15.0 fl 1 0.104 0.054 1.60 0.980 1.00 1.00 1.00 1.00 0.99 6.88 393.19 3764.55 1.59 22.77 424.00
Overall Maximum Deflections
Load Combination Span Max."-" Dell Location in Span Load Combination Max."+" Defl Location in Span
+D+Lr 0.3171 7.555 0.0000 0.000
7 of 30
DAVID THOMAS ENGINEERING,APC Project Title: Reger/Maerowitz Residence
David Thomas, SE , Structural Engineering Services
LD I i \ ;I~:::11:::~:~Y2
Wood Beam
LIC#: KW-06015405, Build:20.22.3.31
DESCRIPTION: FB-1
Vertical Reactions
Engineer:
Project ID: 22124
Project Descr:
Project File: Reger-Maerowitz Residence.ec6
DAVID THOMAS ENGINEERING, A.P.C. (c) ENERCALC INC 1983-2022
Support notation : Far left is #1 Values in KIPS
Load Combination Support 1 Support 2
Overall MAXimum
Overall MINimum
D Only
+D+Lr
+D+0.750Lr
+0.600
Lr Only
4.708 4.708
1.650 1.650
3.058 3.058
4.708 4.708
4.296 4.296
1.835 1.835
1.650 1.650
8 of 30
;\
lo'\ I \ <--···.'. ··•·••····~
DAVID THOMAS ENGINEERING,APC !\ Structural Engineering Services
/ \ Office: (858) 201-3072
L1i:\ ~=~i~:~~!~!:/::~
Wood Beam
Project Title:
Engineer:
Project ID:
Project Descr:
Reger/Maerowitz Residence
David Thomas, SE
22124
Project File: Reger-Maerowitz Residence.ec6
UC#: KW-06015405, Build:20.22.3.31
DESCRIPTION: FB-2
DAVID THOMAS ENGINEERING, A.P.C. (c) ENERCALC INC 1983-2022
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
Analysis Method : Allowable Stress Design
Load Combination : ASCE 7-16
Fb +
Fb -
2,400.0 psi
1,850.0 psi
1,650.0psi
E : Modulus of Elasticity
Wood Species
Wood Grade
Beam Bracing
DF/DF
24F -V4
Completely Unbraced
Fe -Prll
Fe -Perp
Fv
Ft
0(3.65) 1,(1.65)
8.75x12
Span = 22.0 ft
650.0psi
265.0psi
1,100.0 psi
Ebend-xx 1,800.0ksi
Eminbend -xx 950.0ksi
Ebend-yy 1,600.0ksi
Eminbend -yy 850.0ksi
Density 31.21 O pcf
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loading
Point Load : D = 3.650, Lr= 1.650 k@ 11 .0 ft, (P1, FB-1, R2)
DESIGN SUMMARY Design OK
Maximum Bending Stress Ratio = 0.616 1 Maximum Shear Stress Ratio = 0.124 : 1
Section used for this span 8.75x12 Section used for this span 8.75x12
fb: Actual = 1,744.39psi fv: Actual = 41 .12 psi
Fb: Allowable = 2,830.54psi Fv: Allowable = 331.25 psi
Load Combination +D+Lr Load Combination +D+Lr
Location of maximum on span = 11.000ft Location of maximum on span = 21.036 ft
Span# where maximum occurs = Span# 1 Span# where maximum occurs = Span# 1
Maximum Deflection
Max Downward Transient Deflection 0.280 in Ratio= 941 >=360 Span: 1 : Lr Only
Max Upward Transient Deflection Qin Ratio= 0<360 nla
Max Downward Total Deflection 0.954 in Ratio = 276 >=180 Span: 1 : +D+Lr
Max Upward Total Deflection O in Ratio= 0 <180 nta
Maximum Forces & Stresses for Load Combinations
Load Combination l'Jlax Stress Raf,os l'Jlomen! 'values Sfiear 'values
Segment Length Span# M V Cd CFN Ci Cr Cm Ct CL M fb F'b V fv F'v
D Only 0.00 0.00 0.00 0.00
Length = 22. 0 ft 1 0.601 0.123 0.90 0.944 1.00 1.00 1.00 1.00 0.99 21.45 1,225.82 2037.99 2.05 29.33 238.50
+D+Lr 0.944 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00
Length = 22.0 ft 0.616 0.124 1.25 0.944 1.00 1.00 1.00 1.00 0.99 30.53 1,744.39 2830.54 2.88 41 .12 331.25
+D+0.750Lr 0.944 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00
Length = 22.0 ft 0.570 0.115 1.25 0.944 1.00 1.00 1.00 1.00 0.99 28.26 1,614.75 2830.54 2.67 38.17 331.25
+0.60D 0.944 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00
Length = 22.0 ft 1 0.203 0.042 1.60 0.944 1.00 1.00 1.00 1.00 0.98 12.87 735.49 3623.09 1.23 17.60 424.00
Overall Maximum Deflections
Load Combination Span Max. • -" Defl Location in Span Load Combination Max. "+" Defl Location in Span
+D+Lr 1 0.9539 11.080 0.0000 0.000
9 of 30
DAVID THOMAS ENGINEERING,APC
/\ Structural Engineering Services
/ \ Office: (858) 201-3072
Project Title:
Engineer:
Project ID:
Reger/Maerowitz Residence
David Thomas, SE
22124
IE \ Cell: (858) 336-9902
c"~""··'"' david@dtengsd.com
Wood Beam
UC#: KW-06015405, Build:20.22.3.31
DESCRIPTION: FB-2
Vertical Reactions
Load Combination
Overall MAXimum
Overall MINimum
D Only
+D+Lr
+D+0.750Lr
+0.60D
Lr Only
Project Descr:
Project File: Reger-Maerowitz Residence.ec6
DAVID THOMAS ENGINEERING, A.P.C. (c) ENERCALC INC 1983-2022
Support notation : Far left is #1 Values in KIPS
Support 1 Support 2
2.900 2.900
0.825 0.825
2.075 2.075
2.900 2.900
2.694 2.694
1.245 1.245
0.825 0.825
10 of 30
DAVID THOMAS ENGINEERING,APC
/\ Structural Engineering Services
/ \ Office: (858) 201-3072
I E \ Cell: (858) 336-9902
(, •• ~ '"J david@dtengsd.com
Project Title:
Engineer:
Project ID:
Project Descr:
Reger/Maerowitz Residence
David Thomas, SE
22124
Wood Beam Project File: Reger-Maerowitz Residence.ec6
LIC#: KW-06015405, Build:20.22.3.31
DESCRIPTION: FB-3
DAVID THOMAS ENGINEERING, A.P.C. (c) ENERCALC INC 1983-2022
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
Analysis Method : Allowable Stress Design
Load Combination · ASCE 7-16
Boise Cascade Wood Species
Wood Grade Versa Lam 2.0 3100 West
Beam Bracing Completely Unbraced
D 0.16
v v D(0.216) L(0.288) • •
Fb +
Fb -
Fe -Prll
Fe -Perp
Fv
Ft
•
3,100.0psi
3,100.0 psi
3,000.0psi
750.0psi
285.0psi
1,950.0 psi
E : Modulus of Elasticity
Ebend-xx 2,000.0ksi
Eminbend -xx 1,036.83 ksi
Density 41 .760pcf
D(0.42) L(0.56)
D{0.2925) L{0.39)
1 ~ 7x11 .875 ----¼..---7X11.8~75 -l
Span= 18.0 II Span = 11.0 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loading
Load for Span Number 1
Uniform Load : D = 0.030, L = 0.040 ksf, Tributary Width= 7.20 ft, (W 1, FLOOR)
Uniform Load : D = 0.0160 ksf, Tributary Width= 10.0 ft, (W4, WALL ABV)
Load for Span Number 2
Uniform Load : D = 0.030, L = 0.040 ksf, Extent= 0.0 --» 6.750 ft, Tributary Width= 9.750 ft, (W2, FLOOR)
Uniform Load : D = 0.030, L = 0.040 ksf, Extent= 6.50 --» 11.0 ft, Tributary Width= 14.0 ft, (W3, FLOOR)
DESIGN SUMMARY _______ _____ ....
Maximum Bending Stress Ratio = 0.525 1 Maximum Shear Stress Ratio =
Section used for this span 7x11.875 Section used for this span
Design OK
0.430 : 1
7x11 .875
fb: Actual = 1,602.92psi fv: Actual = 122.51 psi
Fb: Allowable = 3 ,052.74psi Fv: Allowable = 285.00 psi
Load Combination +D+L+H, LL Comb Run (LL) Load Combination
Location of maximum on span = 18.000ft Location of maximum on span
+D+L+H, LL Comb Run (LL)
17.095 ft
Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span# 1
Maximum Deflection
Max Downward Transient Deflection 0.222 in Ratio= 972>=360 Span: 2 : L Only, LL Comb Run (•L)
Max Upward Transient Deflection -0.050 in Ratio= 2620>=360 Span: 2 : L Only, LL Comb Run (L *)
Max Downward Total Deflection 0.494 in Ratio= 437>=240 Span: 2 : +D+L+H, LL Comb Run (•L)
Max Upward Total Deflection -0.076 in Ratio= 1746>=240 Span: 2 : +D+L+H, LL Comb Run (L*)
Maximum Forces & Stresses for Load Combinations
Load Combination Max S!ress Ra!,os Momeni v'alues Sfiear v'alues
Segment Length Span# M V Cd CFN Ci Cr Cm Ct CL M fb F'b V fv F'v
+D+H 0.00 0.00 0.00 0.00
Length = 18.0 ft 1 0.322 0.275 0.90 1.000 1.00 1.00 1.00 1.00 0.99 12.15 885.48 2752.71 3.91 70.60 256.50
Length = 11 .0 ft 2 0.320 0.275 0.90 1.000 1.00 1.00 1.00 1.00 0.99 12.15 885.48 2768.34 2.68 70.60 256.50
+D+L+H, LL Comb Run (*L) 1.000 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00
Length = 18.0 ft 1 0.352 0.309 1.00 1.000 1.00 1.00 1.00 1.00 0.98 14.75 1,075.30 3052.74 4.87 87.93 285.00
Length = 11 .0 ft 2 0.350 0.309 1.00 1.000 1.00 1.00 1.00 1.00 0.99 14.75 1,075.30 3072.85 4.87 87.93 285.00
+D+L+H, LL Comb Run (L•) 1.000 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00
Length = 18.0 ft 1 0.463 0.421 1.00 1.000 1.00 1.00 1.00 1.00 0.98 19.39 1,413.10 3052.74 6.65 119.90 285.00
11 of 30
DAVID THOMAS ENGINEERING,APC
, Structural Engineering Services
Project Title:
Engineer:
Project ID:
Reger/Maerowitz Residence
David Thomas, SE
22124 / \ Office: (858) 201-3072
I E \ Cell: (858) 336-9902
C"·"·"·'"c-> david@dtengsd.com
Project Descr:
Wood Beam
UC#: KW-06015405, Build:20.22.3.31
DESCRIPTION: FB-3
DAVID THOMAS ENGINEERING, A.P.C.
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios
Segment Length Span # M V Cd C FN
Length = 11.0 ft 2 0.460 0.421 1.00 1.000
+D+L+H, LL Comb Run (LL) 1.000
Length= 18.0 ft 1 0.525 0.430 1.00 1.000
Length = 11.0 ft 2 0.522 0.430 1.00 1.000
+D+Lr+H, LL Comb Run (*L) 1.000
Length = 18.0 ft 1 0.233 0.198 1.25 1.000
Length= 11.0 ft 2 0.231 0.198 1.25 1.000
+D+Lr+H, LL Comb Run (L*) 1.000
Length = 18.0 ft 1 0.233 0.198 1.25 1.000
Length= 11.0 ft 2 0.231 0.198 1.25 1.000
+D+Lr+H, LL Comb Run (LL) 1.000
Length = 18.0 ft 1 0.233 0.198 1.25 1.000
Length=11.0ft 2 0.231 0.198 1.25 1.000
+D+S+H 1.000
Length=18.0ft 1 0.253 0.215 1.15 1.000
Length=11.0ft 2 0.251 0.215 1.15 1.000
+D+0.750Lr+0.750L+H, LL Cc 1.000
Length= 18.0 ft 1 0.271 0.219 1.25 1.000
Length=11.0 ft 2 0.268 0.219 1.25 1.000
+D+0.750Lr+0.750L+H, LL Cc 1.000
Length= 18.0 ft 1 0.338 0.302 1.25 1.000
Length = 11.0 ft 2 0.334 0.302 1.25 1.000
+D+0.750Lr+0.750L+H, LL Cc 1.000
Length = 18.0 ft 1 0.375 0.307 1.25 1.000
Length = 11 .0 ft 2 0.372 0.307 1.25 1.000
+D+0.750L+0.750S+H, LL Co 1.000
Length= 18.0 ft 1 0.294 0.238 1.15 1.000
Length = 11.0 ft 2 0.291 0.238 1.15 1.000
+D+0.750L+0.750S+H, LL Co 1.000
Length= 18.0 ft 1 0.366 0.328 1.15 1.000
Length = 11.0 ft 2 0.363 0.328 1.15 1.000
+D+0.750L+0.750S+H, LL Co 1.000
Length= 18.0 ft 1 0.407 0.334 1.15 1.000
Length = 11.0 ft 2 0.403 0.334 1.15 1.000
1.000
0.184 0.155 1.60 1.000
0.181 0.155 1.60 1.000
+D+0.60W+H
Length= 18.0 ft 1
Length= 11.0 ft 2
+D+0. 750Lr+0. 750L +0.450W·
Length = 18.0 ft 1 0.213 0.171
1.000
1.60 1.000
1.60 1.000
1.000
0.266 0.236 1.60 1.000
0.262 0.236 1.60 1.000
Length= 11 .0 ft 2 0.210 0.171
+D+0.750Lr+0.750L+0.450W·
Length = 18.0 ft 1
Length = 11 . 0 ft 2
+D+0. 750Lr+0.750L +0.450W-
Length = 18.0 ft 1
Length = 11. 0 ft 2
+D+0.750L+0.750S+0.450W+
1.000
0.296 0.240 1.60 1.000
0.292 0.240 1.60 1.000
1.000
Length = 18.0 ft 1 0.213 0.171 1.60 1.000
1.60 1.000
1.000
Length = 11.0 ft 2 0.210 0.171
+D+0.750L+0.750S+0.450W+
Length= 18.0 ft 1 0.266 0.236 1.60 1.000
1.60 1.000
1.000
0.296 0.240 1.60 1.000
0.292 0.240 1.60 1.000
1.000
Length = 11.0 fl 2 0.262 0.236
+D+0.750L+0.750S+0.450W+
Length = 18.0 ft 1
Length = 11 .0 ft 2
+0.60D+0.60W+0.60H
Length = 18.0 ft 1
Length= 11.0 ft 2
+D+0. 70E+0.60H
0.110 0.093 1.60 1.000
0.109 0.093 1.60 1.000
1.000
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00 0.99
1.00 0.99
1.00 0.98
1.00 0.99
1.00 0.99
1.00 0.98
1.00 0.99
1.00 0.99
1.00 0.98
1.00 0.99
1.00 0.99
1.00 0.98
1.00 0.99
1.00 0.99
1.00 0.98
1.00 0.99
1.00 0.99
1.00 0.98
1.00 0.99
1.00 0.99
1.00 0.98
1.00 0.99
1.00 0.99
1.00 0.98
1.00 0.99
1.00 0.99
1.00 0.98
1.00 0.99
1.00 0.99
1.00 0.98
1.00 0.99
1.00 0.99
1.00 0.98
1.00 0.99
1.00 0.99
1.00 0.97
1.00 0.98
1.00 0.98
1.00 0.97
1.00 0.98
1.00 0.98
1.00 0.97
1.00 0.98
1.00 0.98
1.00 0.97
1.00 0.98
1.00 0.98
1.00 0.97
1.00 0.98
1.00 0.98
1.00 0.97
1.00 0.98
1.00 0.98
1.00 0.97
1.00 0.98
1.00 0.98
1.00 0.97
1.00 0.98
1.00 0.98
Project File: Reger-Maerowitz Residence.ec6
(c) ENERCALC INC 1983-2022
Moment Values
M fb F'b
19.39 1,413.10 3072.85
0.00
21 .99 1,602.92 3052.74
21 .99 1,602.92 3072.85
0.00
12.15 885.48 3795.97
12.15 885.48 3830.88
0.00
12.15 885.48 3795.97
12.15 885.48 3830.88
0.00
12.15 885.48 3795.97
12.15 885.48 3830.88
0.00
12.15 885.48 3499.93
12.15 885.48 3528.24
0.00
14.10 1,027.84 3795.97
14.10 1,027.84 3830.88
0.00
17.58 1,281.19 3795.97
17.58 1,281 .19 3830.88
0.00
19.53 1,423.56 3795.97
19.53 1,423.56 3830.88
0.00
14.10 1,027.84 3499.93
14.10 1,027.84 3528.24
0.00
17.58 1,281.19 3499.93
17.58 1,281.19 3528.24
0.00
19.53 1,423.56 3499.93
19.53 1,423.56 3528.24
0.00
12.15 885.48 4816.70
12.15 885.48 4883.46
0.00
14.10 1,027.84 4816.70
14.10 1,027.84 4883.46
0.00
17.58 1,281.19 4816.70
17.58 1,281.19 4883.46
0.00
19.53 1,423.56 4816.70
19.53 1,423.56 4883.46
0.00
14.10 1,027.84 4816.70
14.10 1,027.84 4883.46
0.00
17.58 1,281 .19 4816.70
17.58 1,281.19 4883.46
0.00
19.53 1,423.56 4816.70
19.53 1,423.56 4883.46
0.00
7.29 531.29 4816.70
7.29 531.29 4883.46
0.00
V
3.34
0.00
6.79
5.53
0.00
3.91
2.68
0.00
3.91
2.68
0.00
3.91
2.68
0.00
3.91
2.68
0.00
4.33
4.33
0.00
5.96
3.17
0.00
6.07
4.82
0.00
4.33
4.33
0.00
5.96
3.17
0.00
6.07
4.82
0.00
3.91
2.68
0.00
4.33
4.33
0.00
5.96
3.17
0.00
6.07
4.82
0.00
4.33
4.33
0.00
5.96
3.17
0.00
6.07
4.82
0.00
2.35
1.61
0.00
Shear Values
fv F'v
119.90
0.00
122.51
122.51
0.00
70.60
70.60
0.00
70.60
70.60
0.00
70.60
70.60
0.00
70.60
70 .60
0.00
78.03
78.03
0.00
107.58
107.58
0.00
109.54
109.54
0.00
78.03
78.03
0.00
107.58
107.58
0.00
109.54
109.54
0.00
70.60
70.60
0.00
78.03
78.03
0.00
107.58
107.58
0.00
109.54
109.54
0.00
78.03
78.03
0.00
107.58
107.58
0.00
109.54
109.54
0.00
42.36
42.36
0.00
285.00
0.00
285.00
285.00
0.00
356.25
356.25
0.00
356.25
356.25
0.00
356.25
356.25
0.00
327.75
327.75
0.00
356.25
356.25
0.00
356.25
356.25
0.00
356.25
356.25
0.00
327.75
327.75
0.00
327.75
327.75
0.00
327.75
327.75
0.00
456.00
456.00
0.00
456.00
456.00
0.00
456.00
456.00
0.00
456.00
456.00
0.00
456.00
456.00
0.00
456.00
456.00
0.00
456.00
456.00
0.00
456.00
456.00
0.00
12 of 30
DAVID THOMAS ENGINEERING,APC Project Title: Reger/Maerowitz Residence
• i /\ Structural Engineering Services Engineer: David Thomas, SE I \ / \ Office: (858) 201-3072 Project ID: 22124
ID \ Project Descr: I \ {E=i Cd ell_:d(@85d8t) 336d-9902 ~7-,·._···:·f avI engs .com
Wood Beam Project File: Reger-Maerowitz Residence.ec6
LIC#: KW-06015405, Build:20.22.3.31 DAVID THOMAS ENGINEERING, A.P.C. (c) ENERCALC INC 1983-2022
DESCRIPTION: FB-3
Maximum Forces & Stresses for Load Combinations
Load Combination lli'lax Stress Ralios Momeni Values Sfiear Values
Segment Length Span# M V Cd CFN C i Cr Cm Ct CL M fb F'b V fv F'v
Length = 18.0 ft 1 0.184 0.155 1.60 1.000 1.00 1.00 1.00 1.00 0.97 12.15 885.48 4816.70 3.91 70.60 456.00
Length = 11.0 fl 2 0.181 0.155 1.60 1.000 1.00 1.00 1.00 1.00 0.98 12.15 885.48 4883.46 2.68 70.60 456.00
+D+0. 750L +0.750S+0.5250E· 1.000 1.00 1.00 1.00 1.00 0.98 0.00 0.00 0.00 0.00
Length = 18.0 ft 1 0.213 0.171 1.60 1.000 1.00 1.00 1.00 1.00 0.97 14.10 1,027.84 4816.70 4.33 78.03 456.00
Length = 11.0 ft 2 0.210 0.171 1.60 1.000 1.00 1.00 1.00 1.00 0.98 14.10 1,027.84 4883.46 4.33 78.03 456.00
+D+O. 750L +0.750S+0.5250E· 1.000 1.00 1.00 1.00 1.00 0.98 0.00 0.00 0.00 0.00
Length = 18.0 ft 1 0.266 0.236 1.60 1.000 1.00 1.00 1.00 1.00 0.97 17.58 1,28 1.19 4816.70 5.96 107.58 456.00
Length = 11.0 ft 2 0.262 0.236 1.60 1.000 1.00 1.00 1.00 1.00 0.98 17.58 1,281.19 4883.46 3.17 107.58 456.00
+D+O. 750L +0.750S+0.5250E-1.000 1.00 1.00 1.00 1.00 0.98 0.00 0.00 0.00 0.00
Length = 18.0 fl 1 0.296 0.240 1.60 1.000 1.00 1.00 1.00 1.00 0.97 19.53 1,423.56 4816.70 6.07 109.54 456.00
Length = 11.0 fl 2 0.292 0.240 1.60 1.000 1.00 1.00 1.00 1.00 0.98 19.53 1,423.56 4883.46 4.82 109.54 456.00
+O .600+0. 70E+H 1.000 1.00 1.00 1.00 1.00 0.98 0.00 0.00 0.00 0.00
Length = 18.0 fl 1 0.110 0.093 1.60 1.000 1.00 1.00 1.00 1.00 0.97 7.29 531 .29 4816.70 2.35 42.36 456.00
Length = 11.0 ft 2 0.109 0.093 1.60 1.000 1.00 1.00 1.00 1.00 0.98 7.29 531.29 4883.46 1.61 42.36 456.00
Overall Maximum Deflections
Load Combination Span Max."-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
+D+L+H, LL Comb Run (L•)
L Only, LL Comb Run (*L)
Vertical Reactions
Load Combination
Overall MAXimum
Overall MINimum
+D+H
+D+L+H, LL Comb Run (*L)
+D+L +H, LL Comb Run (L ")
+D+L+H, LL Comb Run (LL)
+D+Lr+H, LL Comb Run (*L)
+D+Lr+H, LL Comb Run (L *)
+D+Lr+H, LL Comb Run (LL)
+D+S+H
1
2
+D+0.750Lr+0.750L+H, LL Comb Run(*
+D+0.750Lr+0.750L+H, LL Comb Run (L
+D+0.750Lr+0.750L+H, LL Comb Run (L
+D+0.750L+0.750S+H, LL Comb Run (*L
+D+0.750L+0.750S+H, LL Comb Run (L*
+D+0.750L+0.750S+H, LL Comb Run (LL
+D+0.60W+H
+D+0.750Lr+0.750L+0.450W+H, LL Comb
+D+0.750Lr+0.750L+0.450W+H, LL Comb
+D+0.750Lr+0.750L+0.450W+H, LL Comb
+D+0.750L+0.750S+0.450W+H, LL Comb
+D+0.750L+0.750S+0.450W+H, LL Comb
+D+0.750L+0.750S+0.450W+H, LL Comb
+0.60D+0.60W+0.60H
+D+0.70E+0.60H
+D+0.750L+0.750S+0.5250E+H, LL Comb
+D+0.750L+0.750S+0.5250E+H, LL Comb
+D+0.750L+0.750S+0.5250E+H, LL Comb
+0.60D+0.70E+H
DOnly
L Only, LL Comb Run (*L)
L Only, LL Comb Run (L*)
L Only, LL Comb Run (LL)
H Only
0.4940
0.0608
8.246
6.330 +D+L+H, LL Comb Run (L*)
Support notation : Far left is #1
Support 1 Support 2 Support 3
5.116 13.643 3.713
2.045 6.374 1.917
2.926 7.268 1.137
2.781 9.990 3.713
5.116 10.921 0.479
4.971 13.643 3.055
2.926 7.268 1.137
2.926 7 .268 1.137
2.926 7.268 1.137
2.926 7.268 1.137
2.818 9.310 3.069
4.568 10.008 0.644
4.460 12.049 2.575
2.818 9.310 3.069
4.568 10.008 0.644
4.460 12.049 2.575
2.926 7.268 1.137
2.818 9.310 3.069
4.568 10.008 0.644
4.460 12.049 2.575
2.818 9.310 3.069
4.568 10.008 0.644
4.460 12.049 2.575
1.756 4.361 0.682
2.926 7.268 1.137
2.818 9.310 3.069
4.568 10.008 0.644
4.460 12.049 2.575
1.756 4.361 0.682
2.926 7.268 1.137
-0.145 2.722 2.575
2.190 3.652 -0.658
2.045 6.374 1.917
0.0000
-0.0756
Values in KIPS
0.000
3.933
13 of 30
Job Re~r/Maerovitz Residence 21124
Calculated by _ ____,D.....,.T ___ Date ___ _
'
David Thomas Engineering
DESIGN LEVEL: J.P T~ Beam Design
LABEL: t-0-f SPAN = ] FT.
W1 =l _ (0 ~ft 11) ~ f!( fl.f
W2= ~ fJ-f (~) ~ ~t> rr
LABEL: f~-L SPAN= fl'~l> • FT.
W1= 7o f>p ~):~_{ f~
W2= SO f','f (~)=c ~-~
P1 z <t, r Sf ( '6') ( ~) : +. ~o ~ I /I; yz.. a..
~= • ~~ .. lb ~ f tD) ::: /,1> r'-F-, ~._._ ~./.
USE: 3 1/i, X , ·, 7tY v~~ GRADE: s i l:ro C: -
ALT: ____ ___, GRADE: ___ C: __
LABEL: ___ SPAN= ____ FT.
\.
USE: ______ GRADE: ___ C: __
ALT: GRADE: C: __
E= ___ ksl
f,r --·
(I ~ ,,
'
R1 = ~ 71!) lbs. R2 = ~ J1l> lbs
E= ___ ksl
L /J
R1 = ___ lbs. ~= ___ .lbs
E= ___ ksl
14 of 30
DAVID THOMAS ENGINEERING,APC
1
. Structural Engineering Services
/ \ Office: (858) 201-3072
LP E,:\ ~::i~:~~~~!~~::~
Project Title:
Engineer:
Project ID:
Project Descr:
Reger/Maerowitz Residence
David Thomas, SE
21124
Wood Beam Project File: Reger-Maerowitz Residence.ec6
UC#: KW-06015405, Build:20.22.3.31
DESCRIPTION: FB-4
DAVID THOMAS ENGINEERING, A.P.C. (c) ENERCALC INC 1983-2022
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
Analysis Method : Allowable Stress Design
Load Combination : ASCE 7-16
Fb +
Fb -
3,100.0psi
3,100.0psi
3,000.0psi
E : Modulus of Elasticity
Ebend-xx 2,000.0ksi
Fe -Prll
Fe -Perp
Fv
Eminbend -xx 1,036.83ksi
Wood Species
Wood Grade
Beam Bracing
l •
Boise Cascade
Versa Lam 2.0 3100 West
Completely Unbraced
Ft
3.Sx9.5
Span • 7.0 ft
750.0 psi
285.0psi
1,950.0 psi Density 41 .760pcf
I
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loading
Uniform Load : D = 0.030, L = 0.040 ksf, Tributary Width= 6.50 ft, (W1 . FLOOR)
Uniform Load : D = 0.030, Lr= 0.020 ksf, Tributary Width= 16.0 ft, (W2, ROOF)
Uniform Load : D = 0.0160 ksf, Tributary Width= 10.0 ft, (W3, WALL ABV)
DESIGN SUMMARY
Maximum Bending Stress Ratio = 0.509 1 Maximum Shear Stress Ratio
Section used for this span 3.5x9.5 Section used for this span
fb: Actual = 1,542.22psi fv: Actual
Fb: Allowable = 3,031.10psi Fv: Allowable
Load Combination +D+L Load Combination
Location of maximum on span = 3.500ft Location of maximum on span
Span # where maximum occurs = Span# 1 Span # where maximum occurs
Maximum Deflection Max Downward Transient Deflection 0.035 in Ratio = 2416 >=360 Span: 1 : Lr Only
Max Upward Transient Deflection O in Ratio= 0<360 n/a
=
=
=
=
=
Max Downward Total Deflection 0.139 in Ratio= 604 >=240 Span: 1 : +D+0.750Lr+0.750L
Max Upward Total Deflection O in Ratio= 0<240 n/a
Maximum Forces & Stresses for Load Combinations
Load Combination Max S!ress Ra!1os Momeni 'i7alues
Segment Length Span# M V Cd CFN Ci Cr Cm Ct CL M fb F'b
DOnly 0.00
Length = 7.0 ft 1 0.431 0.406 0.90 1.000 1.00 1.00 1.00 1.00 0.98 5.17 1,179.22 2736.23
+D+L 1.000 1.00 1.00 1.00 1.00 0.98 0.00
Length = 7.0 ft 1 0.509 0.478 1.00 1.000 1.00 1.00 1.00 1.00 0.98 6.77 1,542.22 3031 .10
+D+Lr 1.000 1.00 1.00 1.00 1.00 0.98 0.00
Length= 7.0 ft 1 0.433 0.403 1.25 1.000 1.00 1.00 1.00 1.00 0.97 7.13 1,625.98 3756.28
+D+0.750Lr+0.750L 1.000 1.00 1.00 1.00 1.00 0.97 0.00
Length= 7.0 ft 1 0.476 0.443 1.25 1.000 1.00 1.00 1.00 1.00 0.97 7.84 1,786.54 3756.28
+D+0.750L 1.000 1.00 1.00 1.00 1.00 0.97 0.00
Length = 7.0 ft 1 0.418 0.391 1.15 1.000 1.00 1.00 1.00 1.00 0.97 6.37 1,451.47 3468.45
+0.60D 1.000 1.00 1.00 1.00 1.00 0.97 0.00
Design OK
0.478 : 1
3.5x9.5
136.22 psi
285.00 psi
+D+L
6.234 ft
Span# 1
Sfiear 'i7alues
V fv F'v
0.00 0.00 0.00
2.31 104.16 256.50
0.00 0.00 0.00
3.02 136.22 285.00
0.00 0.00 0.00
3.18 143.62 356.25
0.00 0.00 0.00
3.50 157.80 356.25
0.00 0.00 0.00
2.84 128.21 327.75
0.00 0.00 0.00
15 of 30
DAVID THOMAS ENGINEERING,APC
j\ Structural Engineering Services
1 \ Office: (858) 201-3072
IE \ Cell: (858) 336-9902
C."-"~,.d david@dtengsd.com
Wood Beam
Project Title:
Engineer:
Project ID:
Project Descr:
UC#: KW-06015405, Build:20.22.3.31
DESCRIPTION: FB-4
DAVID THOMAS ENGINEERING, A.P.C.
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios
Segment Length Span# M V Cd CFN Ci Cr Cm Ct CL
Length = 7.0 ft 1 0.149 0.137 1.60 1.000 1.00 1.00 1.00 1.00 0.95
Overall Maximum Deflections
Reger/Maerowitz Residence
David Thomas, SE
21124
Project File: Reger-Maerowitz Residence.ec6
(c) ENERCALC INC 1983-2022
Moment Values Shear Values
M fb F'b V fv F'v
3.10 707.53 4734.26 1.39 62.50 456.00
Load Combination Span Max."." Dell Location in Span Load Combination Max. "+" Dell Location in Span
+D+0.750Lr+0. 750L
Vertical Reactions
Load Combination
Overall MAX1mum
Overall MINimum
DOnly
+D+L
+D+Lr
+D+0. 750Lr+0. 750L
+D+0.750L
+0.60D
Lr Only
L Only
0.1390 3.526
Support notation : Far left is #1
Support 1 Support 2
4.479 4.479
0.910 0.910
2.956 2.956
3.866 3.866
4.076 4.076
4.479 4.479
3.639 3.639
1.774 1.774
1.120 1.120
0.910 0.910
0.0000
Values in KIPS
16 of 30
0.000
DAVID THOMAS ENGINEERING,APC
1 Structural Engineering Services
/ \ Office: (858) 201-3072
LP Ei ~;:i~:~~!~!:~9:i~
Project Title:
Engineer:
Project ID:
Project Descr:
Reger/Maerowitz Residence
David Thomas, SE
22124
Wood Beam Project File: Reger-Maerowitz Residence.ec6
LIC#: KW-06015405, Build:20.22.3.31
DESCRIPTION: FB-5
DAVID THOMAS ENGINEERING, A.P.C. (c) ENERCALC INC 1983-2022
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set: ASCE 7-16
Material Properties
Analysis Method : Allowable Stress Design
Load Combination · ASCE 7-16
Fb +
Fb -
3,100.0psi
3,100.0psi
3,000.0psi
E : Modulus of Elasticity
Ebend-xx 2,000.0ksi
Fe -Prll
Fe -Perp
Fv
Eminbend -xx 1,036.83 ksi
Wood Species
Wood Grade
Beam Bracing
Boise Cascade
Versa Lam 2.0 3100 West
Completely Unbraced
D(0.16)
D(0.48) Lr(0.32) 9 V 0 .
Ft
DC0.195\ U0.26\
3.5x11.875
Span= 11.0 n
750.0 psi
285.0psi
1,950.0 psi Density
D(2.88) Lr(1.92)
'
41.760pcf
.
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loading
Uniform Load : D = 0 .030, L = 0.040 ksf, Tributary Width= 6.50 ft, (W1, FLOOR)
Uniform Load : D = 0 .030, Lr= 0.020 ksf, Extent= 0.0 -» 2.50 ft, Tributary Width= 16.0 ft, (W2, ROOF)
Uniform Load : D = 0 .0160 ksf, Extent= 0.0 --» 2.50 ft, Tributary Width= 10.0 ft, (W3, WALL ABV)
Point Load : D = 2.880, Lr= 1.920 k @ 8.50 ft, (P1, HDR REACT)
DESIGN SUMMARY
Maximum Bending Stress Ratio = 0.597. 1 Maximum Shear Stress Ratio =
Section used for this span 3.5x11.875 Section used for this span
fb: Actual = 1,735.02psi fv: Actual =
Fb: Allowable = 2,908.37psi Fv: Allowable =
Load Combination +D+L Load Combination
Location of maximum on span = 6.504ft Location of maximum on span =
Span # where maximum occurs = Span# 1 Span # where maximum occurs =
Maximum Deflection
Max Downward Transient Deflection 0.088 in Ratio= 1498>=360 Span: 1 : L Only
Max Upward Transient Deflection O in Ratio= 0 <360 n/a
Max Downward Total Deflection 0.308 in Ratio= 429>=240 Span: 1 : +D+0.750Lr+0.750L
Max Upward Total Deflection 0 in Ratio= 0<240 n/a
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Rabos Momeni 'values
Segment Length Span# M V Cd CFN Ci Cr Cm Ct CL M fb F'b
D Only 0.00
Length = 11.0 ft 1 0.455 0.471 0.90 1.000 1.00 1.00 1.00 1.00 0.95 8.27 1,205.62 2647.92
+D+L 1.000 1.00 1.00 1.00 1.00 0.95 0.00
Length = 11.0 ft 1 0.597 0.573 1.00 1.000 1.00 1.00 1.00 1.00 0.94 11.90 1,735.02 2908.37
+D+Lr 1.000 1.00 1.00 1.00 1.00 0.94 0.00
Length = 11.0 ft 1 0.506 0.498 1.25 1.000 1.00 1.00 1.00 1.00 0.90 12.15 1,770.77 3497.13
+D+0.750Lr+0.750L 1.000 1.00 1.00 1.00 1.00 0.90 0.00
Length = 11.0 ft 0.564 0.548 1.25 1.000 1.00 1.00 1.00 1.00 0.90 13.52 1,970.95 3497.13
+D+0.750L 1.000 1.00 1.00 1.00 1.00 0.90 0.00
Length = 11.0 ft 1 0.488 0.466 1.15 1.000 1.00 1.00 1.00 1.00 0.92 10.96 1,597.36 3273.96
Design OK
0.573 : 1
3.5x11.875
163.28 psi
285.00 psi
+D+L
10.036 ft
Span# 1
Sfiear 'values
V fv F'v
0.00 0.00 0.00
3.35 120.73 256.50
0.00 0.00 0.00
4.53 163.28 285.00
0.00 0.00 0.00
4.92 177.53 356.25
0.00 0.00 0.00
5.41 195.24 356.25
0.00 0.00 0.00
4.23 152.64 327.75
17 of 30
: \ / \
ID\ I ' ( ................. ,
DAVID THOMAS ENGINEERING,APC
Structural Engineering Services
/ \ Office: (858) 201-3072
IE \ Cell: (858) 336-9902 Z..·······-····) ···--david@dtengsd.com
Wood Beam
Project Tille:
Engineer:
Project ID:
Project Descr:
LIC#: KW-06015405, Build:20.22.3.31
DESCRIPTION: FB-5
DAVID THOMAS ENGINEERING, A.P.C.
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios
Segment Length Span# M V Cd CFN
+0.60D 1.000
Length= 11 .0ft 1 0.176 0.159 1.60 1.000
Overall Maximum Deflections
1.00 1.00
1.00 1.00
Cm Ct CL
1.00 1.00 0.92
1.00 1.00 0.83
Reger/Maerowitz Residence
David Thomas, SE
22124
Project File: Reger-Maerowitz Residence.ec6
(c) ENERCALC INC 1983-2022
Moment 17alues Sliear 17alues
M fb F'b V fv F'v
0.00 0.00 0.00 0.00
4.96 723.37 4114.42 2.01 72.44 456.00
Load Combination Span Max."-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
+D+0.750Lr+0.750L
Vertical Reactions
Load Combination
Overall MAX1mum
Overall MINimum
D Only
+D+L
+D+Lr
+D+0.750Lr+0.750L
+D+0.750L
+0.600
Lr Only
L Only
0.3075 5.741 0.0000 0.000
Support notation : Far left is #1 Values in KIPS
Support 1 Support 2
5.143 5.800
1.430 1.430
3.212 3.546
4.642 4.976
4.357 5.121
5.143 5.800
4.284 4.619
1.927 2.128
1.145 1.575
1.430 1.430
18 of 30
Job Reger/Maerowjtz Residence 22124
Calculated by FR Date ____ _
David Thomas Engineering
LATERAL DESIGN (Sheet 1)
Wind Design
Method Used -Main Wind-Force Resisting System (MWFRS) -Envelope Method -Part 2
Maximum Building Height (z) =~0 feet
Design Wind Speed= 90 mph (per ASCE-7, Figure 26.5-lA)
Exposure Category= C (per ASCE-7, 6.5.6.3)
Importance Factor (I)= 1.00 (per ASCE-7, Table 1.5-2)
K,r = 1.00 (per ASCE-7, 26.8.2)
). = 1.40 (per ASCE-7, Figure 28.5-1)
Ps30 = 17.80 psf (per ASCE-7, Figure 28.5-1)
0.6 x Ps =I 14.95lpsf Ps =Ax K,1 x Ps30 (per ASCE-7, 28.5.3, Equation 28.5-1)
(reduced for ASD load combos)
Adjust Factor A Table
Mean Roof Exposure
Height (ft) B C D
15 1.00 1.21 1.47
20 1.00 1.29 1.55
25 1.00 1.35 1.61
30 1.00 1.40 1.66
35 1.05 1.45 1.70
40 1.09 1.49 1.74
45 1.12 1.53 1.78
so 1.16 1.56 1.81
55 1.19 1.59 1.84
60 1.22 1.62 1.87
Seismic Design
Method used= Equivalent Lateral Force Procedure
Occupancy Category= 2 (per ASCE-7, Table 1-1) (Residential= 2.0)
6.5 R = (per ASCE-7, Table 12.2-1) (Wood Shearwalls = 6.5)
1.00 I= (per ASCE-7, Table 11.5-1) (Residential= 1.0)
Site Class= (per ASCE-7, 11.4.2) (Assume Site Class= "D" w/o Soils Report)
Ss = g (0.2 sec) F. = ~ Sos = 0.777 g
D
0.971
0.355 S1 = g (1 sec) Fv= ~ S01 = 0.460 g
Seismic Design Category (SOS) =
Seismic Design Category (SDl) =
D
D
Ta= 0.256
Cs = 0.120
Csmax = 0.276
Csmtn = 0.010
p = 1.3
sec
Csact =~l
V = 0.111 Wx
(Use the worst case seismic design category)
C1h/ (per ASCE-7, Equation 12.8-7)
S05/(R/I) (per ASCE-7, Equation 12.8-2)
S0i/Ta(R/r (per ASCE-7, Equation 12.8-3)
Csmin > 0.01 or 0.SSi/(R/1) (per ASCE-7, Eq.12.8-5 / 12.8-6)
Assumed
(Csaci*P)*Wxfl.4 (ASD) X
Factor of Safety
1 1.20 I = 10.133
0 30
Job Reger /Maerowitz Residence 22124
Calculated by FR Date ____ _
David Thomas Engineering
BUILDING WEIGHTS
Total Installed Roof Weight
Total Installed Floor Weight
Total Installed Deck Weight
Total Installed Interior Wall Weight
Total Installed Exterior Wall Weight
Commercial Partition Loads?
ROOF LOADS
Diaphragm Area
Exterior Wall Length
Interior Wall Length
Minimum Diaphragm Dimension
2ND FLOOR LOADS
Diaphragm Area
Exterior Wall Length
Interior Wall Length
Minimum Diaphragm Dimension
TOT AL BUILDING DEAD LOAD, WT.
C5(adjusted)
BASE SHEAR, V
LATERAL DESIGN (Sheet 3)
=
=
=
=
=
Roof=
=
=
N-S =
Roof=
=
=
N-S =
25
30
30
7
16
N
1691
191
143
33
1107
292
219
33
psf
psf
psf
psf
psf
Yor N
sq. ft.
ft.
ft.
ft.
sq. ft.
ft.
ft.
ft.
= 185,115.50
= 0.133
= 24,651.04
Roof Project. Height
ffiQQLJPlate Height
~Floor Plate Height
=aft = 9 ft
= 9 ft
* Alternate Ext. Wall = lpsf
Deck =~-----11sq. ft.
Alt.=. _ ft.
E-W=I
TOTAL=
331ft.
60531.5 LBS.
Floor =~sq. ft.
Alt.=C:=Jft.
Deck =._I ___ __.lsq. ft.
LBS.
LBS.
E-W=I
TOTAL=
33 I ft.
124584 LBS.
See Lateral Design Loads Spreadsheet
LATERAL LOAD DISTRIBUTION
Diaphragm Level
Story Weight (wx)
Story Height (hx)
Story Weight x Height (wx x hx)
(wx x hx) / L(w1 x hi)
Story Force (FrxJ
Story Area (A)
Story Unit Shear (vx)
WIND VS. SEISMIC COMPARISON
Wind Pressure (P)
Story Linear Forces
NORTH-SOUTH Wind
NORTH-SOUTH Seismic
EAST-WEST Wind
EAST-WEST Seismic
Story Linear Forces
NORTH-SOUTH Wind
NORTH-SOUTH Seismic
EAST-WEST Wind
EAST-WEST Seismic
ROOF
60.5315 kips
19 ft.
1150.1 kip-ft.
0.50635
12482 lbs.
1691 sq. ft.
7.38 psf
= 14.95 psf
= ROOF
= 14.95 psf X
= 7.38 psf X
= 14.95 psf X
= 7.38 psf X
= 2nd
= 14.95 psf X
= 4.35 psf X
= 14.95 psf X
= 4.35 psf X
2nd
124.584 kips
9 ft.
1121.26 kip-ft.
0.49365
12169 lbs.
2798 sq. ft.
4.35 psf
See Lateral Design Loads Spreadsheet
10.5 ft. 157 plf SEISMIC GOVERNS 33 ft. 244 plf
10.5 tt 157 plf SEISMIC GOVERNS 33 ft 244 plf
10 ft. 150 plf CUMULITIVEL Y
33 ft. 144 plf SEISMIC GOVERNS
10 ft 150 plf CUMULITIVELY
33 tt 144 plf SEISMIC GOVERNS
0 .)
Job Reger/Maerowitz Residence 22124
Calculated by __ __..._D ..... T_ Date ____ _
David Thomas Engineering
Shearwall Design
~ Story Shearwalls p-$ Direction Unit Lateral Load, v = } ,8 psf
Gridllne ___,/....,<, ___ _
Tributary Area (This Level): sq. ft. Lateral Load (This Level): _...,__,f,£-L-=---+--'--'-""2!""-+,___-----------~2i-Lbs
Lateral Load (Level Above): Lbs
Total Load (All Levels), Fx= -------=-"F'I'=~ Lbs
Total Shearwall(s) Length, L = _____________ ft
Unit Wall Shear, V = Fx/L = -----,--plf
Shearwall Type: Q ll)('.is-r-Jl-',
Overturning: Panel Design Width = ___ ft. OR ✓ Okay by Inspection .
U~ft= L~
Holdown Anchor Type: D ------------------
Grldllne {& 'Jfe. '\ C;7) Tributary Area (This Level): ~ ./-
Lateral Load (This Level):
Lateral Load (Level Above):
Total Load (All Leyels), Fx =
Total Shearwall(s) Length, L = _____________ ft.
Unit Wall Shear, v = Fx/L = _____ plf
Shearwall Type: Q ;;~c;.11 ~j;,.
Overt1,1rnlng: Panel Design Width = ___ ft. OR ✓ Okay by Inspection
Uplift= _______ :,__ ________________ Lbs
Holdown Anchor Type: D ------------------
Grldllne _____ _
Tributary Area (This Level): _______________________ sq. ft.
Lateral Load (This Level): Lbs
Lateral Load (Level Above): Lbs
Total Load (All Levels), Fx = ______ Lbs
Total Shearwall(s) Length, L = _____________ ft.
Unit Wall Shear, V = F,JL = ________ plf
• Shearwall Type: Q
Overturning: Panel Design Width = ___ ft. OR __ Okay by Inspection
Uplift=-----------------------,---Lbs
Holdown Anchor Type: D ------------------
J 21 of 30
Job Reger/Maerowitz Residence 22124
Calculated by __ --""DJ.I-Date ___ _
David Thomas Engineering
Shearwall Design
i.J P Story Shearwalls ~ r $ Direction
Total Shearwall(s) Length, L =
Unit Wall Shear, v = F,r/L
Shearwall Type: @ =
Overturning: Panel Design Width = ___ ft. OR
Uplift = e~. ~ t C'l)
Unit Lateral Load, v = f, '~sf
__ Okay by Inspection
7707-1 Lbs
Holdown Anchor Type: . bTI __ '' ..... HP_~~_,, ____________ _
Total Shearwall(s) Length, L
Unit Wall Shear, v = Fx/L
Shearwall Type: ~
Overtumln~: _ ~~ fl , Panel Design Width = ___ ft. OR
. Uphft-~-~ en .. ·,/ • r-n \f u /1
__ Okay by Inspection
4t,f Lbs
Holdown Anchor Type: b.lJ vrt::>1JB _ ___:..;..__;;__. ____________ _
J
• Grldllne !Gt ~\(~/)· d .1jributary_Ar_e_a,._(Th+i-s-Le-ve-l)-: (_:::-v:.l-_ f-'Ct" L -~ g-z_ sq. ft.
Lateral Load (This Level): Af1FLff_ lfW t?y ;;;t.~t;Z;)fi~~ubs
Lateral Load (Level Above): ----------------~--,.........,__,,..-Lbs Total Load (All Levels), Fx= '1-(7/·~bs
Total Shearwall(s) Length, L = ____________ ft.
Unit Wall Shear, v = F.JL = . . plf ,
ShearwallType: o . Ut>E ¼., _ lfss ~ ~~ % ~-4,{ {fxz= toe~ ~ fa-~,~;
Overturning: Panel Design!Width = • ft. OR __ Okay by Inspection A >P.
Uplift= _______________________ Lbs
Holdown Anchor Type: D -----------------
22 of 30
' Job Reger/Maerowitz Residence 22124
Calculated by __ __...,D ...... T_ Date ____ _
David Thomas Engineering
Shearvyall Design
~~p Story Shearwalls, f:! .. V-oirection Unit Lateral Load,·v = _g.,
~r~b~:~J.c~t1P t@{k)C,H +: \Y#)($0) sq.ft
Lateral Load (This Lewi):' .al& Lbs
Lateral Load (Level Above): -------:-----:---=--:---,-----,--------..,,.._..---Lbs
· ; / z(b,} Total Load (All Levels), Fx = ----.,1.~~z .... ffi~•=-+f-Lbs
Total Shearwall(s) Length, L =
Unit Wall Shear, v = F,JL
Shearwall Type: @ =
·~. ~,,,-V ~ 3 77 ft.
lt,o plf
O'lrertumlng: _ . • .. ) .~.-, r~•I Design Wdlh • ___ ft. OR __ Okay by Inspection
Uplift~.'.~~, ·U~ · ' 7 7t{-o Lbs
Holdowhl~chor Type; [il __ '-'_1..,ff __ P_l.1 __ 8 ___ 1 '---,------------
Grldllne _____ _
Tributary Area (This Level):· _______________________ ·sq. fl
Lateral Load (This Level): Lbs
Lateral Load (Level Above): Lbs
Total Load (All Levels), Fx = ______ Lbs
Total Shearwall(s) Length, L = _____________ ft.
Unit Wall Shear, v = Fx/L
Shearwall Type: Q
= _____ plf
Overturning: Panel Design Width = ___ ft. OR __ Okay by Inspection
Uplift= ________________________ Lbs
Holdown Anchor Type: 0 -------------------.--
Grldllne _____ _
Tributary Area (This Level): _______________________ sq. ft.
Lateral Load (This Level): Lbs
Lateral Load (Level Above): Lbs
Total Load {All Levels), Fx = ______ Lbs
Total Shearwall(s) Length, L = _____________ ft.
Unit Wall Shear, V = F./L
Shearwall Type: Q =: -----plf
Overturning: Panel Design Width = ___ ft. OR · __ Okay by Inspection
Uplift= ________________________ Lbs
Holdown Anchor Type: • D ------------------
23 of 30
DAVID THOMAS ENGINEERING,APC Project Title: Reger/Maerowitz Residence
David Thomas, SE I , Structural Engineering Services
/. \ Office: (858) 201-3072
Engineer:
Project ID: 22124 /D I Ej Cell: (858) 336-9902 Project Descr:
david@dtengsd,com
Steel Column Project File: Reger-Maerowitz Residence,ec6
UC#: KW-06015405, Bui :20.22.3.31 DAVID THOMAS ENGINEERING, A.P.C. (c) ENE ALC INC 1983-2022
DESCRIPTION: LATERAL COLUMN GRID 19
Code References
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Steel Section Name : HSS6x6x3/8 Overall Column Height 9.0 ft
Analysis Method : Allowable Strength Top & Bottom Fixity Top Free, Bottom Fixed
Steel Stress Grade Brace condition for deflection (buckling) along columns :
Fy : Steel Yield 46.0 ksi X-X (width) axis :
E : Elastic Bending Modulus 29,000.0 ksi Unbraced Length for buckling ABOUT Y-Y Axis= 9.0 ft, K = 2.1
Y-Y (depth) axis :
Applied Loads
Column self weight included : 247.320 lbs* Dead Load Factor
BENDING LOADS ...
Lat. Point Load at 9.0 ft creating Mx-x, E = 1.520 k
DESIGN SUMMARY
Bending & Shear Check Results
PASS Max. Axial+Bending Stress Ratio =
Load Combination
Location of max.above base
At maximum location values are ...
Pa : Axial
Pn / Omega : Allowabh
Ma-x : Applied
Mn-x I Omega : Allowable
Ma-y : Applied
Mn-y I Omega : Allowable
PASS Maximum Shear Stress Rati,
Load Combination
Location of max.above base
At maximum location values are ...
Va : Applied
Vn / Omega : Allowable
Load Combination Results
0.2652 : 1
+D+0.70E
0.0 ft
0.2473 k
107.309 k
-9.576 k-ft
36.267 k-ft
0.0 k-ft
36.267 k-ft
0.01862 : 1
+D+0.70E
0.0 ft
1.064 k
57.137 k
Maximum Axial+ Bending Stress Ratios
Load Combination
D Only
+0.60D
+D+0.70E
+D+0.5250E
+0.60D+0.70E
Maximum Reactions
Load Combination
OOnly
+0.600
+D+0.70E
+D+0.5250E
+0.600+0.70E
E Only
Stress Ratio Status Location
0.002 PASS 0.00 ft
0.001 PASS 0.00 ft
0.265 PASS 0.00 ft
0.199 PASS 0.00 ft
0.265 PASS 0.00 ft
Axial Reaction
@Base
0.247
0.148
0.247
0.247
0.148
X-X Axis Reaction
@Base @Top
Cbx
1.67
1.67
1.67
1.67
1.67
k
Unbraced Length for buckling ABOUT X-X Axis = 8.0 ft, K = 2.1
Service loads entered. Load Factors will be applied for calculations.
Maximum Load Reactions ..
Top along X-X
Bottom along X-X
Top along Y-Y
Bottom along Y-Y
Maximum Load Deflections ...
Along Y-Y 0.5544 in at
for load combination : E Only
Along X-X 0.0 in at
for load combination:
0.0 k
0.0 k
0.0 k
1.520 k
9.0ft above base
0.0ft above base
Ma11imum S!Jear Ratios Cby KxLx/Ry KyLy/Rx Stress Ratio Status Location
1.00 99.47
1.00 99.47
1.00 99.47
1.00 99.47
1.00 99.47
Y-Y Axis Reaction
@Base
1.064
0.798
1.064
1.520
@Top
88.42 0.000 PASS 0.00 ft
88.42 0.000 PASS 0.00 ft
88.42 0.019 PASS 0.00 ft
88.42 0.014 PASS 0.00 ft
88.42 0.019 PASS 0.00 ft
Note: Only non-zero reactions are listed.
Mx -End Moments k-ft My -End Moments
@Base @Top @Base @Top
-9.576
-7.182
-9.576
-13.680
24 of 30
DAVID THOMAS ENGINEERING,APC
\ Structural Engineering Services
/ \ Office: (858) 201-3072 IE \ Cell: (858) 336-9902
C.,,cc.~,,c-, david@dtengsd.com
Steel Column
Project Title:
Engineer:
Project ID:
Project Descr:
Reger/Maerowitz Residence
David Thomas, SE
22124
Project File: Reger-Maerowitz Residence.ec6
LIC#: KW-06015405, Build:20.22.3.31 DAVID THOMAS ENGINEERING, A.P.C. (c) ENERCALC INC 1983-2022
DESCRIPTION: LATERAL COLUMN GRID 19
Extreme Reactions
Axial Reaction
Item Extreme Value @ Base
Axial@ Base Maximum 0.247
Minimum
Reaction, X-X Axis Base Maximum
" Minimum
Reaction, Y-Y Axis Base Maximum
Minimum
Reaction, X-X Axis Top Maximum
Minimum
Reaction, Y-Y Axis Top Maximum
Minimum
Moment, X-X Axis Base Maximum
Minimum
0.247
0.247
0.247
0.247
0.247
0.247
0.247
0.247
Moment, Y-Y Axis Base Maximum 0.247
Minimum 0.247
Moment, X-XAxis Top Maximum 0.247
Minimum 0.247
Moment, Y-Y Axis Top Maximum 0.247
Minimum 0.247
X-X Axis Reaction
@ Base @ Top
-13.680
Maximum Deflections for Load Combinations
Load Combination Max. X-X Deflection Distance
D Only 0.0000 in 0.000 ft
+0.60D 0.0000 in 0.000 ft
+D+0.70E 0.0000 in 0.000 ft
+D+0.5250E 0.0000 in 0.000 ft
+0.60D+0.70E 0.0000 in 0.000 ft
E Only 0.0000 in 0.000 ft
Steel Section Properties HSS6x6x3/8
Depth = 6.000 in I xx =
Design Thick = 0.349 in s xx =
Width = 6.000 in R xx =
Wall Thick = 0.375 in Zx =
Area = 7.580 in"2 I yy =
Weight 27.480 plf s yy =
R yy
Ycg 0.000 in
k Y-Y Axis Reaction
@ Base @Top
1.520
1.520
1.520
Max. Y-Y Deflection
0.000 in
0.000 in
0.388 in
0.291 in
0.388 in
0.549 in
39.50 in"4
13.20 in"3
2.280 in
15.800 in"3
39.500 in"4
13.200 in"3
2.280 in
Mx -End Moments k-ft My -End Moments
@ Base @Top @ Base @Top
-13.680
-13.680
-13.680
Distance
0.000 ft
0.000 ft
9.000 ft
9.000 ft
9.000 ft
8.940 ft
J
C 22.100 in"3
25 of 30
DAVID THOMAS ENGINEERING,APC Project Title:
, Structural Engineering Services
/ \ Office: (858) 201-3072 /D I E\ Cell: (858) 336-9902
david@dtengsd.com
Engineer:
Project ID:
Project Descr:
Steel Column
LIC#: KW-0601 05, Build:20.22.3.3 AVID THOMAS ENGINEERING, A.P.C.
DESCRIPTION: LATERAL COLUMN GRID 19
Sketches
+Y
.. ,.
+X
6.00in
Reger/Maerowitz Residence
David Thomas, SE
22124
Project File: Reger-Maerowitz Residence.ec6
(c) ENERCALC IN 1983-2022
t
26 of 30
DAVID THOMAS ENGINEERING,APC
; Structural Engineering Services
/ . Office: (858) 201-3072
/ .. E~ ~=~1i~:5d~!~!~~::~
Pole Footing Embedded in Soil
Project Title:
Engineer:
Project ID:
Project Descr:
Reger/Maerowitz Residence
David Thomas, SE
21124
Project File: Reger-Maerowitz Residence.ec6
LIC#: KW-06015405, Build:20.22.3.31 DAVID THOMAS ENGINEERING, A.P.C. (c) ENERCALC INC 1983-2022
DESCRIPTION: POLE FTG AT HSS ALONG GRID 19
Code References
Calculations per IBC 20181807.3, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7 -16
General Information
Pole Footing Shape Rectangular
Pole Footing Width . . . . . . . . . . . . 36.0 in
Calculate Min. Depth for Allowable Pressures
Lateral Restraint at Ground Surface
Allow Passive ......... .
Max Passive .......... .
Controlling Values
Governing Load Combinatilir Only• 0.70
350.0 pcf
1,500.0 psf
Lateral Load 1.064 k
~me~ 9.~6~
Restraint @ Ground Surface
Point Load
Pressure at Depth
Actual
Allowable
Soil Surface Surface Lateral Restraint
i~
Surface Retrain! Force
~lnlmu~ ~equlred De~
Footing Base Area
Maximum Soil Pressure
Applied Loads
Lateral Concentrated Load (k)
D : Dead Load
Lr : Roof Live
L: Live
S: Snow
W :Wind
E : Earthquake
H : Lateral Earth
Load distance above
ground surface
k
k
k
k
k
1.520 k
k
9.0 ft
Load Combination Results
Load Combination
E Only • 0.70
E Only• -0.70
E Only• 0.5250
E Only• -0.5250
985.22 psf
1,093.75 psf
7,575.68 lbs
3.125 !
9.0 ft~2
0.0 ksf
Lateral Distributed Loads (kl
TOP of Load above ground surface
BOTTOM of Load above ground surface
Forces@
Loads-(k)
0.000 0.000
1.064 9.576
1.064 9.576
0.798 7.182
0.798 7.182
k/ft
k/ft
k/ft
k/ft
k/ft
k/ft
k/ft
ft
ft
Requri<I
Depth -(ft)
0.13
3.13
3.13
2.75
2.75
.... ' .... ' '('")
Applied Moment (kft) Vertical Load (k)
k-ft
k-ft
k-ft
k-ft
k-ft
k-ft
k-ft
k
k
k
k
k
k
k
Pressure at Depth Soll Ina-ease
Actual -(psf) Allow-(psf) Factor
0.0 43.8 1.000
985.2 1,093.8 1.000
985.2 1,093.8 1.000
954.2 962.5 1.000
954.2 962.5 1.000
27 of 30
SHEAR~ALL SCHEDULE (201c; CBC)
MARK VALUE MATERIAL NAIL B.N. 4 F .N. SILL PLATE ATTACH. BOT. PLATE ATTACH. TOP PLATE ADDITIONAL
(PLF) SIZE E.N. 5/8"0 A.B. SPACING NAILS 4 SC.REriS CLIPS NOTES
0 260 3/8 " CDX 8d 6" 12" 48' o.c. I6d@ 4" O.C. A35 @ 16" o.c. -
0 340 15/32' CDX IOd 6" 12" 32" O.C. I6d@ 4' o.c. A35 @ 12· o.c. -
0 350 3/8" CDX 8d 4• 12· 32' o.c. I6d@ 4" O.C. A35@ 12" o.c. -
0 550 3/8" STRLJC. I 8d 3" 12· 24' o.c. 114•0 x 8" 'SDS' A35@ 8" O.C. SEE NOTES
SC.REH @ 8" O.C. 13, 14, 4 15
0 130 3/8' STRLJC. I 8d 2" 12" 16' o.c. 114•0 x 8" ·sos· L TP4 @ 8" O.C. SEE NOTES
SC.REH @ 4 • 0 .C. 13, 14, 4 15
0 810 15/32' STRLJC. I IOd 2" 12· 16' O.C. 114•0 x 8" ·sos· L TP4 @ 8" O.C. SEE NOTES
SC.REH @ 4" O.C. 13, 14, 4 15
0 1211 IS/32" STRUC I IOd 2" 12" 8" O.C. 5/8'0 x 8" LAG L TP4 @ 6" O.C. SEE NOTES
(APPLY BOTH SIDES) SC.REH @ 8" O.C. 13, 14, 15, 4 16
~
I. PROVIDE '4-PLl" 5HEATHIN6 o 3/8' THIC.KIESS • 'S-PLY' o 15/32' 5HEATI-IIN6. l"iOOD 5fflJCMAI.. PAI-El.5 SHALL COMPLY l'tTH DOC, PSI OR DOC, P52.
2. ONLY COMMON HAILS ARE TO 6E USED FOR ALL 5HEATl!IN6 ATTACHMENT. NAIL~ U5IN6 'CLIPPED HEAD' OR '5I"8<1:R' NAILS ARE NOT ACCEPTAel.E.
3. ALL 51£AAt'tAU.5 TO Prn:TRATE TrlRCUSH CEILIN6 JOIST AND ATTIC. TO TIE INTO UPPER HORIZONTAL DIAPHv'6M utLf55 EN61tEERED DRA6 t-£M6ER 15 PRESENT.
4. MINIMJH E06E DISTANCE FOR HAILS IN TI-IE REC.EIV1N6 1'£H3ER5 SHALL 6E 3/8' FOR 2' NOMINAL REC.EMN6 MEJ-eERS AND 1/2' FOR 3' NOMINAL RECEIV1N61'EM6ER5.
5. SHEAR PANELS SHALL 6E APPLIED DIRECTl Y TO SlUD FAAM1N6 AT 16' ON CENTER MAXIMJM AND ALL PANEL ED6E5 SHALL 6E BLOCKED i"IITI-1 MINlt-U-1 2x 8LOCKIN6, U.N.O.
6. NO PANEL YilDTrl LE55 THAN 12' SHALL 6E USED. ~5 rllTrl MORE THAN ONE VERTICAL PAI-EL IH 1£I6HT SHALL HAVE HORIZONTAL STA66ERED 5PLIC.ED JOINTS.
1. 5TUGCO AW/OR EXTERIOR YEteR OVER A l"iOOD s.EATI-IIN6 ~ SHALL 6E YiATERPROOFED l'tTH A MINlt-01 OF (2) LAYERS OF 15 LB. FB.T PAPER.
8. U5E Da161..A5 FIR HO. 2 PRE55URE TREATED SILL PLATES THAT c.oMPLY i"IITI-1 TI-IE~-EN6I11:ER TO 6E NOTIFIED IF OTHER 5PECIE5 ARE USED OR PART OF EXISTIN6 BJILDIN6.
'I. 3" x 3' x 0.22'1' /MINJHJM) PLATE YiASl-£l<5 SHALL 8E USED AT ALL~ ANCHOR OOLTS. YiA5l£R SHALL EXTEND TO l'tTrllN 1/2' OF E06E OF TI-IE BOTTOM PLATE ON TI-IE
51£ATl£D SIDE. (SIMPSON 'ElPS-3' o 2 x 4 51\JD FRAMIN6 t "SP5-6' o 2 x 6 AND LAR6ER 51\ID FRAMIN6 ACCEPTABLE)
10. ANCHOR 80LT5 HJST 6E Et-eEDDED 1' MINIMJH INTO tti'I CONCRETE. MIHIMJH EDGE DISTANCE AND c.ot-lCRETE PROTECTION SHALL COMPLY ~!Tri C6C, AND ACI CODE PROVISIONS.
II. SILL PLATES TO 6E ATTAat:D 1151N6 A MINIMJH OF (2) ANCHOR 80LT5 PER PIECE ~ITH ANCHOR 80LT5 LOCATED 4-3/8' MINIMJH t 12' MAXIMJH FROM EACH END.
12. HOL.DOl'fl ANCHOR 15 IH ADDITION TO TI-IE SILL ANC-IIOR 80L TS.
13. 3x SILL PLATES (BOTTOM PLATES TO REMAIN 2x), 3x BI..OCKIN6 t 3x Sl\JDS o ALL PANEL EDGES REGlUIRED.
14. 4x 8LOCKIN6 OR SEAM REGUIRED SEL~ BOTTOM PLATE 5GREl1 ATTACHI-ENT. 5GREl'6 TO 6E 5TA66ERED.
15. PERIODIC. SPEC.JAL INSPECTION REGlUIRED PER C.ElC CHAPTER 11. ONE t TI'IO FAMILY Dl'til.lN65 LE55 THAN TI'IO STORIES IN 1£I6HT A60VE GRADE "10 IRRE6l.tARJTIE5 ARE EXEMPT.
,, 16. 51£ATHIN6 APPLIED TO EACH FACE OF 3x Sl\JDS o 16' O.C.. STA661:R HORIZONTAL• VERTICAL PAIEL JOINTS EACH SIDE OF t'W.L. N
°" l 11. ALL NAILS SHALL HAVE A MIHII-U-1 PENETRATION INTO FAAMIN6 t-£1-flERS OF 1-1/2 INGl-£5. 8d cot+10N • 0.131'11 x 2-1/2', IOd GOl+'OH • 0.148'11 x 3'. Q _ .....
...,,
0
0
Sl) <: -· p..
-3 ~
0 a
Sl)
C/)
tT:l = OQ -· = (1)
(1)
"'1 -· = OQ
n ~
C"l s:: ~ rt (1)
Q.,
a-'<
"'Tl ;a
0
0J rt (1)
-0 a-
;a
(I) co (I) -, I s::
ll)
I ~ ~ ;::..: N
;a
Ii
::J
(")
(I)
N N _..
N ~
Job Reger-Maerowitz Residence 22124
Calculated by __ F_R __ Date ___ _
David Thomas Engineering
HOLD-DOV'{N SCHEDULE
MARK HOLD-DO~N DEVICE VALUE
0 4x POST~/ 11MSTC4011 FLR-TO-FLR H.D. 3,080 LBS.
@] 4x POST ~/ 11MSTC52 11 FLR-TO-FLR H.D. 4,620 LBS.
@] 4x POST ~/ 11MSTC6611 FLR-TO-FLR H.D. 5,860 LBS.
~ 4x POST ~/ 11MSTC48B311 FLR-TO-FLR H.D. 3,'l15 LBS.
[] 4x POST ~/ "MSTC66B3" FLR-TO-FLR H.D. 4,505 LBS.
[] 4x POST~/ "HDU211 HOLD-DO~N 3,015 LBS. ON SSTBl6 AB. (5/811r/J AB.)
0 4x POST ~/ 11HDU411 HOLD-DO~N 4,565 LBS. ON SSTB20 AB. (5/811r/J AB.)
[8J 4x POST ~/ 11HDU511 HOLD-DO~N 5,645 LBS. ON SSTB24 AB. (5/811r/J AB.)
0 bx POST ~/ 11HDU811 HOLD-DO~N 1,810 LBS. ON SSTB28 AB. (1/811r/J AB.)
cg bx POST ~/ 11HDUII" HOLD-DO~N 'l,335 LBS. ON SB lx30 AB. (l11r/J AB.)
[I] bx POST ~/ "HDUl4" HOLD-DO~N 14,445 LBS. ON SB lx30 AB. (l"r/J AB.)
[8J -------------------------------------
[BJ -------------------------------------
NOTES,
I. HOLD DO~ ANC.HORS 1'1.JST BE TIED IN PLAC.E PRIOR TO FOUNDATION INSPEC.TION.
2. DEEPEN FOOTINGS TO PROVIDE :3" MIN. CONCRETE WYER Vil-lERE HOLD-DO~N
ANC.HORS ARE LONGER THAN THE FOOTING DEPTH.
:3. USE (RJ) OPTION ON STHD HOLD-DOriNS FOR RAISED Y'IOOD SUB-FLOOR C.ONDITION.
4. MSTC HOLD-DO~NS MAY USE 16d SINKERS OR IOd COMMON NAILS.
5. MSTC. HOLD-DO~NS TO BE C.ENTERED BEmEEN UPPER 4 LO~ FLOORS. MAXl1'1.JM
CLEAR SPAN = 18". NAILS NOT REQUIRED IN C.LEAR SPAN (RIM BOARD) AREA.
?Q of 30
!~/, 1D \ 1E\ • I \ L ............... \ ................. ,
Job Reger-Maerowitz Residence 22124
Calculated by FR Date __ _
David Thomas Engineering
SPREAD FOOTING SCHEDULE
SYMBOL SPREAD FOOTING DIMENSIONS 4 REINF.
(f1G = 2,500 PSI MIN. 4 f~ = 60 KSI)
~ 2411 SQ. X 18 II DEEP SPREAD FOOTING
'I'!/ (2)-#4 BARS (EACH ~A Y)
-0> 30" SQ. x 18 11 DEEP SPREAD FOOTING
'I'll (3 )-#4 BARS (EACH ~A Y)
-0> 36" SQ. x 18" DEEP SPREAD FOOT ING
~/ (4)-#4 BARS (EACH ~AY)
~ 42" SQ. x 18 II DEEP SPREAD FOOTING
~/ (5)-#4 BARS (EACH ~AY)
-0> 48" SQ . x _!_~11 DEEP SPREAD FOOTING
'I'll (6)-#4 BARS (EACH ~AY)
30 of 30
STORM WATER POLLUTION PREVENTION NOTES
1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE
AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION
OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN
IS EMINENT.
2. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION
CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION
OF THE CITY INSPECTOR AFTER EACH RUN-OFF PRODUCING
RAINFALL.
3. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION
CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY
INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR
UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE.
4. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE
AT THE END OF EACH WORKING DAY WHEN THE FIVE (5)
DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT
( 40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER
EACH RAINFALL.
5. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM
AGGREGATE.
6. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER
PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST
BE INSTALLED AND MAINTAINED.
7. THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER
THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED
TO ENSURE COMPLIANCE WITH CITY STORM WATER QUALITY
REGULATIONS.
OWNER'S CERTIFICATE:
I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT
BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION
ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID
THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO
AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCTION
RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES,
COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP
THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES
UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED
BY THE CITY OF CARLSBAD.
CLA~f,{/
12-/12/22
DA
E-29
STORM WATER COMPLIANCE FORM
TIER 1 CONSTRUCTION SWPPP
BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE
Erosion Control Sediment Control BMPs Tracking Non-Storm Water
BMPs Control BMPs Management BMPs
C
C C 0 .....
0 0 ~ C
-0 ~ ~ 0, 0 Q)
C E "' 0 0 C C Ol ..... 0 ..... ::, ::, 0 '6 ·;:: C. 0 E L. L. ~ L. ~ -0 (/) Ol L. Q) ..... ..... C '-::,
Ol C Q) L. C Q) c "'(/) "' 0 ·;:: 0-C. Q) ·;:: C > L. Best Management Practice* <Id C Oo 0 ·o.. -C en L. <.!) w CD L. 0 Q) 0 Q)
:E "' 3:
(I) ~ Q) C Q) ..... C E 0 u L. u "' -0 "' ~ -0
(BMP) Description "' 0 Q) (/') 0, Q) Ol CD •o C Ol ➔ ·o Q) "' C C Q) :5 ;:!: Q) ..... 0 0 3: C L. 0 -g~ -0 >, 0"' Cc 0 ~ L. 0 C Cl 0 CD (I')•-0, Cl·-u Q) Oo 0,
X ~ 0 o> Cl C Q) 0::: E 0 ..... N en :!lo 0 C'I~ Q) ~ ·'= Q) 0 Q) E .Y. v ..... ::, ..0 E al ;: ~ = 3: "-+i ::0 ..... -0 ..C C Q) LL. 0 .... Q) ::, -0 ·--0 Q) 0 cO 0 C
0 -+-'•-0 . '6 Q) > ......... ..0 .... ..0 0 ·-.... 0 ·-0 0 .... 0 0 ..... Q) 0 Q) 0 C 0 0 0 Ol .B 0 ..... 0 ~& ..... ..c Q) Q) ~ 0 .... Q) ..c ..0 .... .;;o 0 ..... L. V> C
0 L. 0 ~u <.!) WO V5 c?i (/') u i.i: <.!) (/')> (/') (/') a.. (/') 0::: ~a.. a..o a..
CASQA Designation ➔ r--co a, ~ ....., v lO co r--co 0 N ....., r--co 'T ~ 'T I I I I I I I I I I I I I I I I u u u u w w w w w w w w ~ ~ (/') (/) (/') (/)
Construction Activity w w w w (/') (/') (/') (/') (/') (/) (/') (/') z z z z
Gradinq/Soil Disturbance
Trenchina/Excavation
Stockoilinq
Drillina/Borina
~y Concrete/ Asohalt Sawcuttinq
IX Concrete Flatwork
Pavinq
Conduit/Pioe Installation
IV. Stucco/Mortar Work
1--X Waste Disposal
Staainq/Lav Down Area
Eauioment Maintenance and Fuelina
Hazardous Substance Use/Storaae
Dewaterinq
Site Access Across Dirt
Other (lisfr
Instructions:
1. Check the box to the left of all applicable construction activity ( first column) expected to occur during construction.
Waste Management and Materials
Pollution Control BMPs
..... C -0 Q) C -0 E C 0 0 Q) Q) >, 0, ..... L. 0 C "' Q) 0 > C 0 ~ ~ ..... Q) 0 ..... v "' ~ C Q) C C
Cl :::, Q) ..... Q) "' Q) > ~E Q) Q) ::, E
~~ 0 'o.. L. -~ Q) 0 Q)
·;:: a.. e Ol -0 0, .... 0 Q) .Y. -0 0 so Q) .... 0 _ .....
..... 0 ..... 0 = C •-C NC o....,. 0 ..... 0. 0 <50 oo
~(/') ~ (/') (/') u (/)~ ::i:::~
~ N ....., v lO co
I I I I I I
~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
2. Located along the top of the BMP Table is a list of BMP's with it's corresponding California Stormwater Quality Association (CASQA) designation number. Choose one
or more BMPs you intend to use during construction from the list. Check the box where the chosen activity row intersects with the BMP column.
3. Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project.
Q) ..... "' 0-+-' ~c Q)
a, E ..... Q) ~ 0, oo
CC 0 0 u~
co
I
i
PROJECT INFORMATION
Site Address:2-3!12-/4JA1(6LLoW f)J, 1 2 oocP
Page 1 of 1
Assessor's Parcel Number:2 .12.-fL(2,,-~2-Q0
Emergency Contact:
Name: vOf//lJ {!Uj$f /V
24 Hour Phone: /60 ?IS'. 77'-AJ
Construction Threat to Storm Water Quality
(Check Box)
0 MEDIUM O LOW
REV 11 /17
( City of
Carlsbad
PURPOSE
CLIMATE ACTION PLAN
CONSISTENCY CHECKLIST
B-50
Development Services
Building Division
1635 Faraday Avenue
442-339-2719
www.carlsbadca.gov
This checklist is intended to help building permit applicants identify which Climate Action Plan (CAP) ordinance requirements
apply to their project. This completed checklist (8-50) must be included with the building permit application. The Carlsbad
Municipal Code (CMC) can be referenced during completion of this document by clicking on the provided links to each
municipal code section.
NOTE: The following type of permits are not required to fill out this form
❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool
Consultation with a certified Energy Consultant is encouraged to assist in filling out this document. Appropriate
certification includes, but is not limited to: Licensed, practicing Architect, Engineer, or Contractor familiar with Energy
compliance, IECC/HERS Compliance Specialist, ICC GB Energy Code Specialist, RESNET HERS rater certified, certified
ICC Residential Energy Inspector/Plans Examiner, ICC Commercial Energy Inspector and/or Plans Examiner, ICC CALgreen
Inspector/Plans Examiner, or Green Building Residential Plan Examiner.
If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance,
check N/A and provide an explanation or code section describing the exception.
Details on CAP ordinance requirements are available at each section by clicking on the municipal code link provided. The
project plans must show all details as stated in the applicable Carlsbad Municipal Code (CMC) and/or Energy Code and
Green Code sections.
Property Address/APN: Z)'t'l... lJfof {r<-ld/,1/ &I q lJt:k:P
Applicant Name/Co.: fv l)l) /VJ /:l€. /2u(l()I Lh
.Z 3 f 2 1-v Ill f ff L 1-ou/ /Jd CJ fifl.L-~!.iJ/J , LA , Cj 2 o<J<P Applicant Address:
Contact Phone: 7~0 . 2. 7 /. / J)7£ Contact Email:
Contact information of person completing this checklist (if different than above):
Name:
B-50
Contact Phone7 b O . / / S-:. '7 / ~ <.J
Page 1 of 7
J 12c q11 (j) OUIT.L-uut<, CvlVf
CA q;_o;o
/ 1, /1 z.,/f-2_
I J
Revised 05/22
Use the table below to determine which sections of the Ordinance checklist are applicable to your project. For
alterations and additions to existing buildings, attach a Permit Valuation breakdown on a separate sheet.
Building Permit Valuation (BPV) $ breakdown _______ _
Construction Type Complete Section(s) Notes: :a Residential
A high-rise residential building is 4 or more stories, including a
Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor
area is residential use
□ New consbuction 2A*, 3A*, 18, 2B, *Includes detached, newly constructed ADU 4A*, 38, 4A
~ Additions and alterations:
.EI BPV < $60,000 N/A N/A All residential additions and alterations
□ BPV ~ $60,000 1A, 4A 4A 1-2 family dwellings and townhouses with attached garages
□ Electrical service panel upgrade only only.
□ BPV ~ $200,000 1A, 4A*
*Multi-family dwellings only where interior finishes are removed
1 B, 4A* and significant site work and upgrades to structural and
mechanical, electrical, and/or plumbing systems are proposed
□ Nonresidential
□ New consbuction 1 B, 2B, 38, 48 and 5
D Alterations:
□ BPV ~ $200,000 or additions ~ 1,000 18, 5 square feet
□ BPV ~ $1,000,000 18,28,5 Building alterations of~ 75% existing gross floor area
□ ~ 2,000 sq. ft. new roof addition 28,5 1 B also applies if BPV ~ $200,000
Checklist Item
Check the appropriate boxes, explain all not applicable and exception items, and provide supporting calculations and documentation as necessary.
1. Energy Efficiency
Please refer to Carlsbad Municipal Code (CMC) 18.21.155 and 18.30.190,and the California Green Building Standards Code (CALGreen) for more
information. Appropriate details and notes must be placed on the plans according to selections chosen in the design.
A D Residentialadditionoralteration~$60,000buildingpennitvaluation. □ N/A __________ _
Details of selection chosen below must be placed on the plans referencing CMC □ Exception: Home energy score ~ 7
18.30.190. (attach certification)
Year Built Single-family Requirements Multi-family Requirements
□ Before 1978 Select one option :
□ Ductsealing D Attic insulation □Cool roof □ Attic insulation
□ 1978 and later Select one option:
□ Lighting package □ Water heating Package
□ Between1978and1991 Select one option:
□ Ductsealing D Attic insulation D Cool roof
□ 1992 and later Select one option:
□ Lighting package □ Water heating package
Updated 4/16/202 1 3
8. D Nonresidential* new construction or alterations~ $200,000 building permit valuation,
or additions~ 1,000 square feet. See CMC 18.21.155 and CALGreen Appendix AS D N/A
AS.203.1.1 Choose one:□ .1 Outdoor lighting □ .2 Restaurant service water heating (CEC 140.5)
D . 3 Warehouse dock seal doors. □ .4 Daylight design PAFs D . 5 Exhaust air heat recovery □ N/ A
AS.203.1.2.1 Choose one:□ .95 Energy budget (Projects with indoor lighting OR mechanical)
□ .90 Energy budget (Projects with indoorlighting AND mechanical) □ N/ A
AS.211 .1 ** □ On-site renewable energy:
D N/A
AS.211.3** □Green power: (If offered by local utility provider, 50% minimum renewable sources)
D N/A
AS.212.1 □ Elevators and escalators: (Project with more than one elevator or two escalators)
D N/A
AS.213.1 □ Steel framing : (Provide details on plans for options 1-4 chosen)
□ N/A
* Includes hotels/motels and high-rise residential buildings
----------
•• Foralterations~ $1,000,000 BPVandaffecting > 75% existing gross floor area, OR alterations thatadd 2, OOOsquarefeetof new roofaddition: comply
with CMC 18.30.130 (section 28 below) instead.
2. Photovoltaic Systems
A D Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California
Energy Code section 150.1 (c)14 for requirements. If project includes installation of an electric heat pump water heater pursuant to
CAP section 38 below(low-rise residential Water Heating), increase system size by .3kWdc if PV offset option is selected.
Floor Plan ID (use additional CFA #d.u. Calculated kWdc*
sheets if necessary)
Total System Size:
kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.)
*Formula calculation 'Mlere CFA = conditional floor area, #du= number of dv-.,ellings per plan type
If proposed system size is less than calculated size, please explain.
kWdc
Exception
D
D
D
D
8. D Nonresidential new construction or alterations ~$1,000,000 8PV AND affecting ~75% existing floor area, OR addition that increases
roof area by ~2,000 square feet Please refer to CMC 18.30.130 when completing this section. *Note: This section also applies to
high-rise residential and hotel/motel buildings.
Choose one of the following methods:
□ Gross Floor Area (GFA)Method
GFA:
□ If< 1 O,OOOs.f. Enter: 5 kW de
Min. System Size:
□ If~ 10,000s.f. calculate: 15 kWdcx (GFN10,000) ••
kWdc
**Round building size factor to nearest tenth, and round system size to nearest whole number.
Updated 4/16/202 1 4
D Time-Dependent Valuation Method
AnnualTDVEnergy use:*** ______ x .80= Min. system size: ______ kWdc
***Attach calculation documentation using modeling software approved by the California Energy Commission.
3. Water Heating
A D Residential and hotel/motel new construction. Refer to CMC 18.30.170 when completing this section.
Provide complete details on the plans.
□ For systems serving individual dwelling units choose one system:
D Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise
residential only)
D Heat pump water heater AND PV system .3 kWdc larger than required in CMC 18.30.130 (high rise
residential hotel/motel) or CA Energy Code section 150.1 (c) 14 (low-rise residential)
D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher
D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors
D Exception:
D For systems serving multiple dwelling units, install a central water-heating system with ALL of thefollowing:
D Gas or propane water heating system
D Recirculation system per CMC 18.30.150(8) (high-rise residential, hotel/motel) or CMC 18.30.170(8) (low-
rise residential)
D Solar water heating system that is either:
□ .20 solar savings fraction
□ .15 solar savings fraction, plus drain water heat recovery
□ Exception:
B. D Nonresidential new construction. Refer to CMC 18.30.150 when completing this section. Provide
complete details on the plans.
□ Water heating system derives at least 40% of its energy from one of the following (attach documentation):
□ Solar-thermal □ Photovoltaics □ Recovered energy
□ Water heating system is (choose one):
□ Heat pump water heater
□ Electric resistance water heater(s)
□Solar water heating system with .40 solar savings fraction
□ Exception:
It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to
demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a
performance approach to comply with energy-related measures will need to attach to this checklist separate calculations
and documentation as specified by the ordinances.
Updated 4/ 16/21 5
4. Electric Vehicle Charging
A D Residential New construction and major alterations*
Please refer to CMC 18.21.140 when completing this section.
□ One and two-family residential dwelling or townhouse with attached garage:
□ One EVSE Ready parking space required □Exception:
□ Multi-familyresidential· □ Exception •
Total Parking Spaces EVSE Spaces
Proposed EVSE (10% of total) Installed (50% of EVSE)J Other "Ready" I Other "Capable"
I I
Calculations: Total EVSE spaces= .1 Ox Total parking spaces proposed (rounded up to nearestwholenumber) EVSE Installed= Total EVSE
Spaces x .50 (rounded up to nearest whole number) EVSE other may be "Ready" or "Capable"
*Major alterations are: (1 )foroneand two-family dwellings and townhouses with attached garages, alterations have a building permit
valuation<! $60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached
garages), alterations have a building permit valuation<! $200,000, interiorfinishes are removed and significant site work and upgrades to
structural and mechanical, electrical, and/or plumbing systems are proposed.
*ADU exceptions for EV Ready space (no EV ready space required when):
(1) The accessory dwelling unit is located within one-half mile of public transit.
(2) The accessory dwelling unit is located within an architecturally and historically significant historic district.
(3) The accessory dwelling unit is part of the proposed or existing primary residence or an accessory structure.
(4) When on-street parking permits are required but not offered to the occupant of the accessory dwelling unit.
(5) When there is a car share vehicle located within one block of the accessory dwelling unit.
B. D Nonresidential new construction (includes hotels/motels) □ Exception: ____________ _
Please refer to CMC 18.21.150 when completing this section
Total Parking Spaces
Proposed EVSE (10% of total) I Installed (50% of EVSE) I Other "Ready" I Other "Capable"
I I I
Calculation· Refer to the table below·
Total Number of Parking Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces
□ 0-9 1 1 □ 10-25 2 1
□ 26-50 4 2
□ 51-75 6 3
□ 76-100 9 5
□ 101-150 12 6 □ 151-200 17 9
□ 201 andover 10 percent of total 50 percent of Required EV Spaces
Calculations: Total EVSE spaces= .10x Total parking spaces proposed (rounded up to nearestwhole number) EVSE Installed = Total EVSE
Spaces x .50 (rounded up to nearest whole number) EVSE other may be "Ready" or "Capable"
Updated 4/1 6/2021 6
'
5. □Transportation Demand Management (TDM): Nonresidential ONLY
An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT.
City staff will use the table below based on your submitted plans to determinewhetherornoryourpermit requires a TOM plan. If TOM is applicable to your
permit, staff will contact the applicant to develop a site-specific TOM plan based on the permit details.
Acknowledgment:
Employee ADT Estimation for Various Commercial Uses
Use
Office (all)2
Restaurant
Retai'3
Industrial
Manufacturing
Warehousing
EmpADTfor
first 1,000 s.f.
20
11
8
4
4
4
EmpADTI
1000 s.f.1
13
11
4.5
3.5
3
1
1 Unless otherwise noted, rates estimated from /TE Trip
Generation Manual, 101hEdition
2 For all office uses, use SAN DAG rate of 20 ADT/1,000 sf to
calculate employee ADT
3 Retail uses include shopping center, variety store, supermarket,
gyms, pharmacy, etc.
Other commercial uses may be subject to special
consideration
sample ca!cy!atjons·
Office: 20,450 sf
1. 20,450 sf / 1000 x 20 = 409 Employee ADT
Retail: 9,334 sf
1. First 1,000 sf = 8 ADT
2. 9,334 sf -1,000 sf = 8,334 sf
3. {8,334 sf / 1,000 x 4.5) + 8 = 46 Employee ADT
I acknov.Aedge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should
my permit require a TDM plan and understand that an approved TDM plan is a condition of permit issuance.
Applicant Signature:. __________________ _ Date: ______ _
Person other than Applicant to be contacted for TDM compliance (if applicable):
Name(Printed): __________________ _ Phone Number: _____ _
Email Address: ___________________ _
Updated 4/16/2021 7
Building Permit Finaled
Revision Permit
Print Date: 07/19/2024
Job Address: 2342 LONGFELLOW RD,
Permit No:
Status:
Ccityof
Carlsbad
PREV2022-0149
Closed -Finaled
Permit Type: BLDG-Permit Revision
CARLSBAD, CA 92008-3829
Work Class: Residential Permit Revision
Parcel#: 2121424200
Valuation: $78,471.56
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Occupant Load:
Code Edition: 2019
Sprinkled:
Project Title:
Track#:
Lot#:
Project#:
Plan#:
Construction Type:
Orig. Plan Check#: CBR2022-1645
Plan Check#:
Applied: 12/12/2022
Issued: 01/20/2023
Fina led Close Out: 07/19/2024
Final Inspection:
INSPECTOR:
Description: REGER/MAEROWITZ: REVISION TO INTERIOR BEAM// ADDITION (36 SF)/REMODEL (1556 SF)/PATIO (321 SF)
Applicant:
DEBORAH SHEWAGA
2600 ARGONAUTA ST
CARLSBAD, CA 92009-6501
FEE
BUILDING PLAN CHECK FEE (manual)
Total Fees: $120.00
Building Division
Property Owner:
CO-OWNERS PAMELA REGER AND TODD
MAEROWITZ
2342 LONGFELLOW RD
CARLSBAD, CA 92008-3829
Total Payments To Date: $120.00
Contractor:
CHAPARRAL BUILDERS LLC
3712 JETTY PT
CARLSBAD, CA 92010-5537
(760) 715-7740
Balance Due:
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
AMOUNT
$120.00
$0.00
Page 1 of 1
l_ City of
Carlsbad
PLAN CHECK REV~SION OR
DEFERRED SUBMITTAL
APPLICATION
B-15
C/3R.. Z...o'2..'2.-/ ftt,'-(S-
De velopment Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
Original Plan Check Numbe, ___ _ ____ Plan Revision Number ?/lJlfJ ZD Z'2 ,,. DI fi
Project Address Z.. 312-L,uu {(1L Low f2c) ClJAD q20 ....... u'--'-'cf? _______ _
General Scope ofRevision/Deferred Submittal: &v uqs fa[) !]t, 5-5 /6g [-i1.£A fl1
CONTACT INFORMATION:
Name:IuHJ./ CuJs<iAJ Phond&O 7LS:-77L/O Fax~-----
Address 37/2_ -I-1Y!f $}: Ciry{!l3/JD zif}20J{)
Email Address ✓ 11..c L/ L / {g {)u li DUI? ,. Co /1,1
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1. Elements revised: D Plans _ft(l Calculations D Soils D Energy D Other
2.
Describe revisions in detail
R
4. Does this revision, in any way, alter the exterior of the project? D Yes
5. Does this revision add ANY new floor area(s)? D Yes .ID No
6. Does this revision affect any fire related issues? D Yes i\J No
7.
3.
List page/s) where each
revision is shown
1635 Faraday Avenue, Carls ad, CA 92008 Ph: 760-602-27 19 Fax: 760-602-8558 Email: building@carlsbadca.gov
www.carlsbadca.gov
E
David Thom
Engineering, J.
Structural Engineerin~
Structural Calculations
(Steel Beam Addendum)
Project
REGER/MAEROWITZ Residence/ 22124
2342 Longfellow Road
San Diego, California 92008
Prepared For
Deborah Shewaga
Ideal Design Systems,Inc.
2600 Argonauta Street
Carlsbad, California 92008
11-7-22
Mailing: 3525 Del Mar Heights Ro ad, #331, San Diego, California 92130
Physical: 12625 High Bluff Drive, Suite 302, San Diego, California 92130
Office Phone: (858) 201-3072 Cell Phone: (858) 336-9902
Website: www.dtengsd.com Email: david@dtengsd.com
~w DAVID THOMAS ENGINEERING
1' , '· Structural Engineering Services
, \ Phone: (858) 201-3072 D\ E \ Email: david@dtengsd.com ---=-=--l ;.__:______; Website: www.dtengsd.com
Project Title:
Engineer:
Project ID:
Project Descr:
Reger/Maerowitz Residence
David Thomas, SE
21124
Steel Beam Project File: Reger-Maerowitz Residence.ec6
LIC#: KW-06015405, Build:20.22.8.17
DESCRIPTION: FB-3 Steel
CODE REFERENCES
DAVID THOMAS ENGINEERING, A.P.C.
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
(c) ENERCALC INC 1983-2022
Analysis Method :Allowable Strength Design
Beam Bracing : Completely Unbraced
Bending Axis : Major Axis Bending
Fy : Steel Yield :
E: Modulus :
50.0 ksi
29,ooo.o ksi
Span = 30.0 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loading
Uniform Load : D = 0.030, L = 0.040 ksf, Tributary Width = 7 .0 ft, (Floor Grid 16 -18)
Uniform Load : D = 0.0160 ksf, Tributary Width = 10.0 ft, (W4, WALL ABV)
Uniform Load : D = 0.030, L = 0.040 ksf, Extent= 18.0 -» 30.0 ft, Tributary Width = 3.0 ft, (Floor Grid 16 -18)
Point Load: D = 0.9450, L = 1.260 k@ 18.0 ft, (Existing Floor Beam)
DESIGN SUMMARY
Maximum Bending Stress Ratio =
Section used for this span
Ma: Applied
Mn / Omega : Allowable
Load Combination
Span # where maximum occurs
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
0:314: 1
W1 2x96
106.002 k-ft
337.600 k-ft
+D+L+H
Span# 1
0.292 in Ratio =
0.000 in Ratio=
0.704 in Ratio=
0.000 in Ratio=
Maximum Forces & Stresses for Load Combinations
Load Combination lvlax Stress Ral1os
Maximum Shear Stress Ratio =
Section used for this span
Va: Applied
Vn/Omega : Allowable
Load Combination
1,234
0
511
0
Location of maximum on span
Span # where maximum occurs
>=360
<360 Span: 1 : L Only
>=240. Span: 1 : +D+L +H
<240.0
Summary ol lvlomenl 'values
Segment Length Span# M V Mmax+ Mmax-Ma Max Mnx Mnx/Omega Cb Rm
+D+H
Dsgn. L = 30.00 ft 0.184 0.060 61.71 61.71 560.37 335.55 1.15 1.00
+D+L+H
Dsgn. L = 30.00 ft 0.314 0.104 +D+Lr+H 106.00 106.00 563.79 337.60 1.15 1.00
Dsgn. L = 30.00 ft 0.184 0.060 61 .71 61.71 560.37 335.55 1.15 1.00 +D+S+H
Dsgn. L = 30.00 ft 0.184 0.060 61.71 61.71 560.37 335.55 1.15 1.00 +D+0. 750Lr+0. ?SOL +H
Dsgn. L = 30.00 ft 0.281 0.093
+D+0. 750L +0. 750S+H
94.91 94.91 563.30 337.31 1.15 1.00
Dsgn. L = 30.00 ft 0.281 0.093
+D+0.60W+H 94.91 94.91 563.30 337.31 1.15 1.00
Dsgn. L = 30.00 ft 0.184 0.060 61.71 61 .71 560.37 335.55 1.15 1.00
Design OK
0.104 : 1
W12x96
14.529 k
139.70 k
+D+L+H
30.000 ft
Span# 1
Summary ol Sfiear v'alues
Va Max VnxVnx/Omega
8.42 209.55 139.70
14.53 209.55 139.70
8.42 209.55 139.70
8.42 209.55 139.70
13.00 209.55 139.70
13.00 209.55 139.70
8.42 209.55 139.70
DAVID THOMAS ENGINEERING
, Structural Engineering Services
Phone: (858) 201-3072 D E Email: david@dtengsd.com
~ --=-.i Website: www.dtengsd.com
Steel Beam
Project Title:
Engineer:
Project ID:
Project Descr:
Reger/Maerowitz Residence
David Thomas, SE
21124
Project File: Reger-Maerowitz Residence.ec6
UC#: KW-06015405, Build:2022.8.17
DESCRIPTION: FB-3 Steel
DAVID THOMAS ENGINEERING, A.P.C. (c) ENERCALC INC 1983-2022
Maximum Forces & Stresses for Load Combinations
Load Combination l'vlax stress Ra!1os Summary of l'vlomenl 17alues Summary of Sfiear 17alues
Segment Length Span # M V Mmax+ Mmax-Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega
+D+0. 750Lr+0. ?SOL +0.450W+H
Dsgn. L = 30.00 ft 1 0.281 0.093 94.91 94.91 563.30 337.31 1.15 1.00 13.00 209.55 139.70
+D+0.750L +0. 750S+0.450W+H
Dsgn. L = 30.00 ft 1 0.281 0.093 94.91 94.91 563.30 337.31 1.151.00 13.00 209.55 139.70
+0.60D+0.60W+0.60H
Dsgn. L = 30.00 ft 0.110 0.036 37.03 37.03 560.37 335.55 1.15 1.00 5.05 209.55 139.70
+D+0.70E+0.60H
Dsgn. L = 30.00 ft 1 0.184 0.060 61.71 61.71 560.37 335.55 1.15 1.00 8.42 209.55 139.70
+D+0.750L +0. 750S+0.5250E+H
Dsgn. L = 30.00 ft 1 0.281 0.093 94.91 94.91 563.30 337.31 1.15 1.00 13.00 209.55 139.70
+0.60D+0. 70E+H
Dsgn. L = 30.00 ft 1 0.110 0.036 37.03 37.03 560.37 335.55 1.151.00 5.05 209.55 139.70
Overall Maximum Deflections
Load Combination Span Max.·-• Def! Location in Span Load Combination Max. "+" Deft Location in Span
+D+L+H
Vertical Reactions
Load Combination
Overall MAX1mum
Overall MINimum
Support 1
+D+H
+D+L+H
+D+Lr+H
+D+S+H
+D+0. 750Lr+0. 750L +H
+D+0.750L +0. 750S+H
+D+0.60W+H
+D+0.750Lr+0.750L+0.450W+H
+D+0.750L+0.750S+0.450W+H
+0.60D+0.60W+0.60H
+D+0.70E+0.60H
+D+0.750L +0.750S+0.5250E+H
+0.60D+0.70E+H
D Only
LOnly
H Only
12.576
4.550
7.584
12.576
7.584
7.584
11.328
11.328
7.584
11.328
11.328
4.550
7.584
11.328
4.550
7.584
4.992
0.7043 15.257
Support 2
14.529
5.053
8.421
14.529
8.421
8.421
13.002
13.002
8.421
13.002
13.002
5.053
8.421
13.002
5.053
8.421
6.108
Support notation : Far left is#·
0.0000 0.000
Values in KIPS