Loading...
HomeMy WebLinkAbout6195 EL CAMINO REAL; ; AS060248; Permit8/29/24, 9:42 AM AS060248 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS060248 6195 EL CAMINO Job Address: Status: ISSUED REAL Permit Type: SPRINK Applied 10/16/2006 Parcel No: 2131001800 Approved: 10/16/2006 Lot#: 0 Reference No.: Issued: 10/16/2006 PC#: Inspector: Project Title: MAMA MELACES IN-RACKS Applicant: LIFEGUARD FIRE PROTECTION STE F 2605 TEMPLE HEIGHTS DR OCEANSIDE, CA 760-806-9997 I about:blank Fees($) 120 Add'I Fees ($) 0 Owner: MAMAS HOUSE L L C 6195 EL CAMINO REAL CARLSBAD CA +- Total($) 120 Balance($) 0 7 -1 1/1 ASO0D243 LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR . STE: F, OCEANSIDE, CA 92056 (7 60) 806-9997 • FAX (760) 806-4813 Hydraulic Design Information Sheet IN-RACK PROOF CALCULATION Name: MAMA MELLACE'S IN-RACK S Date: September 21, 2006 Location: 6195 EL CAMINO REAL Building: System No. _G_-_RA_C_K ____ _ Contractor: LIFEGUARD FIRE PROTECTION, INC. Contract No. Calculated By: LCH Drawing No. 2 OF 2 Construction: _,□---c-o-m-bu-s-ti-bl-e--~t8J~-N-o-n--C-o_m_b_u_s-tib_l_e _____ Ceiling Height _______ F_t_. SYSTEM DESIGN ~ NFPA 13: LJ Light Hazard Ordinary Haz.ard Group LJ 1 LJ 2 LJ 3 LJ Extra Hazard 0 NFPA231 0 NFPA 231C: Figure: Curve: D Other (Specify) □specific Ruling Made By Date Area of Sprinkler Operation 6 HEADS+ ROOF Sxstem Twe Density 15 PSI/ .255/3000 ROOF ~ Wet □ Dry D Deluge D Pre-Action Area Per Sprinkler 100 SQ.FT. MAX. Sprinkler or Nozzle Hose Allowance GPM: Inside 100 Make RASCO Model FlFR Hose Allowance GPM: Outside 400 Size ½ K-factor: 5.6 Rack Sprinkler Allowance Temperature Rating 155 DEG. CALCULATION SUMMARY GPM Required 1284.44 PSI Required 48.24 At Base of Riser ------------------"C" Factor Used: Overhead 120 Under ound 150 WATER SUPPLY Water Flow Test Pump Data Tanlc or Reservoir Date & Time 9-7-06 I 8:30 AM Rated Capacity Capacity Static PSI 130 At PSI Elevation Residual PSI 125 Elevation GPMFlowing 1678 Well Elevation 0 Proof Flow GPM Location SITE Source of Information LIFEGUARD FIRE WITH CARLSBAD WATER COMMODITY STORAGE Commodity MIXED NUTS Class ID Location Storage Height 21 '-0" -24'-0" Area 7,909 SQ.FT. Aisle Width 8'-0" Storage Method: Solid Piled % Palletized 100 %Rack 100 Rack . D SingleRow [:8J Conventional Pallet D Automatic Storage D Encapsulated D DoubleRow D Slave Pallet 0 Solid Shelving [:8J Non-Encapsulated .. [:8J Multiple Row 0 Open Flue Spacing In Inches Clearance From Top of Storage to Ceiling Longitudinal 6" Transverse 6" Ft. In. Horizontal Barriers Provided MAMA MELLACES IN-RACK 6 HEADS@ 15 PSI+ .255/3000 ROOF Sigma Dynamic, Corporation 7700 Supply / Demand Graph ~· ../ ~ ,\~~ ~ ~ ~ - ..,µQ, ~ / JO 400 600 800 ;ystem Demand .. prinkler Demand 67,21 PSI ddi tional Flows ose at Source otal Demand 70.26 PSI 1000 1200 @ 1184.44 GPM 100.00 GPM 400.00 GPM @ 1684.44 GPM Moee• • -1400-. WatM Flow (GPM) I Margin - Pressure 42. 20 PSI -Flow 4253.99 GPM I t s '• 't N1.85 1600 1800 Water Supply .. Static 117.00 PSI Residual 112.50 PSI@ 1678.00 GPM Elevation 0.00 PSI 2000 SUBMITTAL SERIAL NO:4144HY1 09-20-2006 PAGE 1 MAMA MELI.ACES IN-RACK 6 HEADS@ 15 PSI+ .255/3000 ROOF REMOTE RACK FLOW TEST RESULTS Water Supply STATIC 117.00 PSI RESIDUAL 112 .50 PSI @ 1678.00 GPM CITY PRESSURE AVAILABLE AT 1684.4 GPM 112.47 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE ---------------- 100 43.48 25.50 8.00 29 .53 101 36.58 25.50 8.00 20.91 102 36.50 25.50 8.00 20 .82 103 36.48 25.50 8.00 20.79 104 43.38 25.50 8.00 29.40 105 35.52 25.50 8.00 19.71 106 35.44 25.50 8 .00 19.62 107 35.42 25 .50 8.00 19.60 108 43.35 25 .50 8.00 29.36 109 34.67 25.50 8.00 18.79 110 34 .60 25 .50 8.00 18.70 111 34.57 25.50 8.00 18.68 113 34.03 25.50 8.00 18.09 114 33.95 25.50 8.00 18.01 115 33.93 25.50 8.00 17.99 117 33 .56 25 .50 8.00 17.60 118 33.49 25.50 8.00 17.52 119 33.47 25.50 8.00 17.50 121 33.25 25 .50 8.00 17.28 122 33.18 25.50 8.00 17.20 123 33.16 25.50 8.00 17 .18 125 33.07 25 .50 8.00 17.09 126 33 .00 25 .50 8.00 17.01 127 32.97 25.50 8.00 16.99 129 32.98 25 .50 8.00 17.00 130 32.91 25.50 8.00 16.92 131 32.89 25 .50 8 .00 16 .90 133 32 .96 25 .50 8.00 16.98 SUBMITTAL SERIAL NO :4144HY1 09-20-2006 PAGE 2 MAMA MELLACES IN-RACK 6 HEADS@ 15 PSI+ .255/3000 ROOF REMOTE RACK SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR -------- 134 32.88 25 .50 8.00 135 32.86 25 .50 8.00 50 23.38 21 .68 5.60 51 23.00 21.68 5.60 52 22 .74 21 .68 5.60 53 22.59 21.68 5.60 54 22.52 21 .68 5.60 55 21.68 21 .68 5 .60 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 4 OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 11 TO 21 PRESSURE -------- 16 .90 16 .88 17 .43 16.86 16.49 16.28 16.18 14.99 1184.44 GPM 100.00 GPM 400.00 GPM 1684.44 GPM 70.26 PSI 0.39 PSI 17 .14 FPS SUBMITIAL SERIAL NO:4144HY1 09-20-2006 PAGE 3 MAMA MELLACES IN-RACK 6 HEADS @ 15 PSI + .255/3000 ROOF REMOTE RACK Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 45 55 1. 049 L 6.50 C=120 PT 14.99 55) Q 21.68 F=T F 5.00 PE 0.00 AO T 11.50 0.1511 PF 1. 74 PT 16.73 45) ------------------ 44 54 1. 049 L 6.50 C=120 PT 16.18 54) Q 22.52 F=T F 5.00 PE 0.00 AO T 11.50 0.1621 PF 1.86 PT 18.04 44) ------------------ 43 53 1.049 L 6.50 C=120 PT 16 .28 53) Q 22.59 F=T F 5.00 PE 0.00 AO T 11.50 0.1631 PF 1.88 PT 18.16 43) ------------------42 52 1.049 L 6.50 C=120 PT 16.49 52) Q 22.74 F=T F 5.00 PE 0.00 AO T 11.50 0.1651 PF 1. 90 PT 18.39 42 ) ------------------41 51 1.049 L 6.50 C=120 PT 16.86 51) Q 23.00 F=T F 5.00 PE 0.00 AO T 11.50 0.1685 PF 1.94 PT 18.80 41 ) ------------------ 40 50 1.049 L 6.50 C=120 PT 17.43 50) Q 23.38 F=T F 5.00 PE 0.00 AO T 11.50 0.1737 PF 2.00 PT 19.43 40) ------------------131 135 2.703 L 8.00 C=l20 PT 16.88 ( 135) Q 32.86 F=0 F 0.00 PE 0.00 BN T 8.00 0 .0032 PF 0 .03 127 131DQ 32.89 2.703 L 8 .00 C=120 PT 16.91 ( 131) Q 65.75 F=0 F 0.00 PE 0.00 BN T 8.00 0.0117 PF 0.09 123 127DQ 32.97 2.703 L 8.00 C=l20 PT 17.00 (127) Q 98.72 F=0 F 0.00 PE 0.00 BN T 8.00 0.0248 PF 0.20 119 123DQ 33.16 2.703 L 8.00 C=l20 PT 17.20 (123) Q 131. 88 F=0 F 0.00 PE 0.00 BN T 8.00 0.0425 PF 0.34 SUBMITI'AL SERIAL NO:4144HY1 09-20-2006 PAGE 4 MAMA MELI.ACES IN-RACK 6 HEADS @ 15 PSI + .255/3000 ROOF REMOTE RACK Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 115 119DQ 33.47 2.703 L 8.00 C=120 PT 17.54 (119) Q 165.35 F=0 F 0.00 PE 0.00 BN T 8.00 0.0645 PF 0.52 111 115DQ 33.93 2.703 L 8.00 C=120 PT 18.06 (115) Q 199.28 F=0 F 0.00 PE 0.00 BN T 8.00 0.0911 PF 0.73 107 lllDQ 34.57 2.703 L 8.00 C=120 PT 18.79 (111) Q 233.85 F=0 F 0.00 PE 0.00 BN T 8.00 0.1225 PF 0.98 103 107DQ 35.42 2.703 L 8.00 C=l20 PT 19.77 (107) Q 269.27 F=0 F 0.00 PE 0.00 BN T 8.00 0.1590 PF 1. 27 23 103DQ 36.48 2.703 L 19.75 C=120 PT 21.04 (103) Q 305.74 F=T F .16.70 PE 0.00 BN T 36.45 0.2011 PF 7.33 13 23 2.703 L 1.83 C=120 PT 28.37 23) Q 305.74 F=T F 16.70 PE 0.79 NR T 18.53 0.2011 PF 3.73 PT 32.89 13) ------------------130 134 I 2 • 703 L 8.00 C=120 PT 16.90 (134) Q 32.88 F=0 F 0.00 PE 0.00 BN T 8.00 0.0033 PF 0.03 126 130DQ 32.91 2.703 L 8.00 C=l20 PT 16.93 (130) Q 65.79 F=0 F 0.00 PE 0.00 BN T 8 .00 0.0117 PF 0.09 122 126DQ 33.00 2.703 L 8.00 C=l20 PT 17.02 (126) Q 98.79 F=0 F 0.00 PE 0.00 BN T 8.00 0.0249 PF 0.20 118 122DQ 33.18 2.703 L 8.00 C=l20 PT 17.22 (122) Q 131. 97 F=0 F 0.00 PE 0.00 BN T 8.00 0.0425 PF 0.34 114 118DQ 33.49 2.703 L 8.00 C=120 PT 17.56 (118) Q 165.45 F=0 F 0.00 PE 0.00 BN T 8.00 0.0646 PF 0.52 110 114DQ 33.95 2.703 L 8.00 C=120 PT 18.08 (114) Q 199.41 F=0 F 0.00 PE 0.00 BN T 8.00 0.0912 PF 0.73 SUBMITI'AL SERIAL NO:4144HY1 09-20-2006 PAGE 5 MAMA MELLACES IN-RACK 6 HEADS @ 15 PSI + .255/3000 ROOF REMOTE RACK Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 106 llODQ 34.60 2 .703 L 8.00 C=120 PT 18.81 (110) Q 234.00 F=0 F 0 .00 PE 0.00 BN T 8.00 0.1226 PF 0.98 102 106DQ 35.44 2 .703 L 8.00 C=l20 PT 19.79 (106) Q 269.44 F=0 F 0.00 PE 0.00 BN T 8.00 0.1592 PF 1 .27 22 102DQ 36.50 2.703 L 19.75 C=120 PT 21.06 (102) Q 305.94 F=T F 16.70 PE 0.00 BN T 36.45 0.2014 PF 7.34 12 22 2 .703 L 1.83 C""120 PT 28.40 22) Q 305.94 F=T F 16 .70 PE 0.79 NR T 18.53 0.2014 PF 3.73 PT 32.92 12) ------------------129 133 2 .703 L 8.00 C=l20 PT 16.98 (133) Q 32.96 F=0 F 0.00 PE 0.00 BN T 8.00 0.0033 PF 0.03 125 129DQ 32 .98 2 .703 L 8.00 C=120 PT 17.01 (129) Q 65.95 F=0 F 0.00 PE 0.00 BN T 8.00 0.0118 PF 0.09 121 125DQ 33 .07 2.703 L 8.00 C=120 PT 17.10 (125) Q 99.02 F=0 F 0.00 PE 0.00 BN T 8.00 0.0250 PF 0.20 117 121DQ 33.25 2.703 L 8.00 C=l20 PT 17.30 (121) Q 132.27 F=0 F 0.00 PE 0.00 BN T 8.00 0.0427 PF 0.34 113 117DQ 33.56 2.703 L 8 .00 C=l20 PT 17 .64 (117) Q 165.84 F=0 F 0.00 PE 0.00 BN T 8.00 0.0649 PF 0.52 109 113DQ 34 .03 2.703 L 8 .00 C=120 PT 18.16 (113) Q 199.86 F=0 F 0.00 PE 0.00 BN T 8.00 0.0916 PF 0 .73 105 109DO 34.67 2.703 L 8.00 C=l20 PT 18.89 (109) Q 234.54 F=0 F 0.00 PE 0.00 BN T 8 .00 0.1232 PF 0.99 101 105DQ 35.52 2.703 L 8.00 C=l20 PT 19.88 (105) Q · 270.06 F=0 F 0.00 PE 0.00 BN T 8.00 0.1599 PF 1.28 SUBMITTAL SERIAL NO:4144HY1 09-20-2006 PAGE 6 MAMA MBLLACES IN-RACK 6 HEADS @ 15 PSI + .255/3000 ROOF REMOTE RACK Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss summary From To GPM IN Devices Ft PSI/Ft PSI 21 l0lDQ 36.58 2.703 L 19.75 C=l20 PT 21.16 (101) Q 306.64 F=T F 16.70 PE 0.00 BN T 36.45 0.2022 PF 7.37 11 21 2.703 L 1.83 C=l20 PT 28.53 21) Q 306.64 F=T F 16.70 PE 0.79 NR T 18.53 0.2022 PF 3.75 PT 33.07 11) ------------------ 104 108 2.703 L 8.00 C=l20 PT 29.36 (108) Q 43.35 F=0 F 0.00 PE 0.00 BN T 8.00 0.0054 PF 0.04 100 104DQ 43.38 2.703 L 8.00 C=l20 PT 29.40 (104) Q 86.73 F=0 F 0.00 PE 0.00 BN T 8.00 0.0196 PF 0.16 20 l00DQ 43.48 2.703 L 19.75 C=120 PT 29.56 (100) Q 130.20 F=T F 16.70 PE 0.00 BN T 36.45 0.0415 PF 1.51 10 20 2.703 L 1.83 C=120 PT 31.07 ( 20) Q 130.20 F=T F 16.70 PE 0.79 NR T 18.53 0.0415 PF 0.77 PT 32.63 10) ------------------ 44 45 2.203 L 9.67 C=l20 PT 16.73 45) Q 21.68 F=2E F 9.60 PE 1.01 FM2 T 19.27 0.0041 PF 0.08 43 44DQ 22.52 2.203 L 7.33 C=l20 PT 17.82 ( 44) Q 44.20 F=0 F 0.00 PE 0.00 FM2 T 7.33 0.0152 PF 0.11 42 43DQ 22.59 2.203 L 7.33 C=l20 PT 17.93 ( 43) Q 66.80 F=0 F 0.00 PE 0.00 FM2 T 7.33 0.0327 PF 0.24 41 42DQ 22.74 2.203 L 7.33 C=120 PT 18.17 ( 42) Q 89.54 F=0 F 0.00 PE 0.00 FM2 T 7.33 0.0562 PF 0.41 40 41DQ 23.00 2.203 L 7.33 C=l20 PT 18.58 ( 41) Q 112.54 F=0 F 0.00 PE 0.00 FM2 T 7.33 0.0857 PF 0.63 SUBMITTAL SERIAL NO:4144HY1 09-20-2006 PAGE 7 MAMA MELLACES IN-RACK 6 HEADS @ 15 PSI + .255/3000 ROOF REMOTE RACK Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 31 40DQ 23.38 2.203 L 18.00 C=120 PT 19.21 ( 40) Q 135 .92 F=E,T F 16.40 PE -6.50 FM2 T 34.40 0.1215 PF 4.18 30 31 2.203 L 96.33 C=120 PT 16.89 ( 31) Q 135.92 F=T F 11.60 PE 0.00 FMl T 107 .93 0.1215 PF 13.11 8 30 2.203 L 5.50 C=l20 PT 30.00 ( 30) Q 135.92 F=E,T F 16.40 PE 0.00 FMl T 21.90 0.1215 PF 2.66 7 8 2.203 L 22.33 C=l20 PT 32.66 8) Q 135.92 F=E F 4.80 PE 9.68 FRl T 27.13 0.1215 PF 3.30 5 7 2.203 L 2.00 C=120 PT 45.64 7) Q 135.92 F=T F 11.60 PE 0.00 FRl T 13.60 0.1215 PF 1. 65 PT 47.29 5) ------------------12 13 6.357 L 12.50 C=120 PT 32.52 13) Q 305.74 F=0 F 0.00 PE 0.00 FM T 12.50 0.0031 PF 0.04 11 12DQ 305.94 6.357 L 12.50 C=120 PT 32.56 ( 12) Q 611.68 F=0 F 0.00 PE 0.00 FM T 12.50 0 .0113 PF 0.14 10 llDQ 306.64 6.357 L 12.50 C=120 PT 32.70 ( 11) Q 918.32 F=0 F 0.00 PE 0.00 FM T 12.50 0 .0239 PF 0.30 6 l0DQ 130.20 6.357 L 93.67 C=120 PT 33.00 ( 10) Q 1048.53 F=2E F 25.14 PE 0.00 FM T 118.81 0.0305 PF 3.62 5 6 6.357 L 23.00 C=120 PT 36.62 6) Q 1048.53 F=0 F 0.00 PE 9.97 FR T 23.00 0.0305 PF 0.70 4 5DQ 135.92 6.357 L 1.00 C=120 PT 47.29 5) Q 1184.44 F=E F 12.57 PE 0.43 FR T 13.57 0.0383 PF 0 .52 2 4DQ 100.00 6.340 L 12.50 C=140 PT 48.24 4) Q 1284.44 F=2E F 46.22 PE 0.00 UN T 58.72 0.0339 PF 1. 99 .., SUBMITTAL SERIAL NO:4144HY1 09-20-2006 PAGE 8 MAMA MELLACES IN-RACK 6 HEADS@ 15 PSI+ .255/3000 ROOF REMOTE RACK Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 1 2 5.914 L 95.00 C=150 PT 50.23 2) Q 1284.44 F=2E F 43.14 PE 0.00 UN T 138.14 0.0418 PF 5.77 0 1 5.914 L 40.00 C=lS0 PT 56.00 1) Q 1284.44 F=T,GV,4E/DCA F 137.12 PE 0.00 UN T 177.12 0.0418 PF 7.40 6 11 DOUBLE CHECK DETECTOR ASSEMBLY 6.84 PT 70.24 0) LIFEGUARD FI RE PRO TECTION, INC. 2605 TEMPLE H E IGHTS DR . ST E: F, OCEANSID E, CA 92056 (7 60 ) 806 -9 99 7 • F AX (7 60 ) 806 -481 3 Hydraulic Desif.Ul Information Sheet IN-RACK . REH o, E. C,A...LC Name: MAMA MELLACE'S IN-RACK S Date: September 21, 2006 Location: 6195 EL CAMINO REAL Building: System No. NC -RACK Contractor: LIFEGUARD FIRE PROTECTION, INC. Contract No. Calculated By: LCH Drawing No. 2 OF 2 Construction: ....,□---C-o_m_b_u_s_ti-bl-e--~[gj---N-o-n--C-o_m_b_u_s-tib_l_e _____ Ceiling Height _______ F_t_. SYSTEM DESIGN NFPA 13: Light Hazard Ordinary Hazard Group 2 3 Extra Hazard 0 NFPA231 0 NFPA231C: Figure: Curve: D Other (Specify) □Specific Ruling _____________ Made By Date ------ Area of Sprinkler Operation Density Area Per Sprinkler 6 HEADS + ROOF System Type 15 PSI/ .255/3000 ROOF ll;'.I Wet O Dry O Deluge O Pre-Action 100 SQ.FT. MAX. Sprinkler or Nozzle 100 Make RASCO Model FlFR ----------Hose Allowance GPM: Inside Hose Allowance GPM: Outside Rack S rinkler Allowance 400 Size ½ K-factor: 5.6 -----------------------l Tern rature Ratin 155 DEG. CALCULATION SUMMARY GPM Required 1160.28 PSI Required 40.34 At Base of Riser ------------------"C" Factor Used: Overhead 120 Under ound 150 WATER SUPPLY Water Flow Test Pump Data Tank or Reservoir Date & Time 9-7-06 I 8:30 AM Rated Capacity Capacity Static PSI 130 At PSI Elevation Residual PSI 125 Elevation GPMFlowing 1678 Well Elevation 0 Proof Flow GPM Location SITE Source of Information LIFEGUARD FIRE WITH CARLSBAD WATER COMMODITY STORAGE Commodity MIXED NUTS Class m Location Storage Height 21 '-0" -24'-0" Area 7,909 SQ.FT. Aisle Width 8'-0" Storage Method: Solid Piled % Palletized 100 %Rack 100 Rack D SingleRow ll;'.I Conventional Pallet D Automatic Storage D Encapsulated D DoubleRow D Slave Pallet 0 Solid Shelving ll;'.I Non-Encapsulated ll;'.I Multiple Row 0 Open Flue Spacing In Inches Clearance From Top of Storage to Ceiling Longitudinal 6" Transverse 6" Ft. In. Horizontal Barriers Provided MAMA MELLACES IN-RACK 6 HEADS@ 15 PSI + .255/3000 ROOF Sigma Dynamic• Corporation 7700 Supply/ Demand Graph 250 240 230 220 210 200 190 180 170 160 150 140 130 120, 110 100 • 90 80 70 60 50 40 30 20 10 . i DY 1..--"' ~· L/ ,-t'--I.,..,"' s~ ~ 0200 400 I., 600 800 1000 1200 System Demand .. Sprinkler Demand 56.10 PSI@ Additional Flows 1060.28 GPM 100.00 GPM 400.00 GPM @ 1560.28 GPM Hose at Source Total Demand 58.66 PSI .. oae- 1400 Water Flow (GPM) I Margin .___ Pressure 54.41 PSI .___ Flow 5133.73 GPM I ~ • s ~ I N 1.85 1600 1800 Water Supply .. Static 117.00 PSI Residual 112.50 PSI@ 1678.00 GPM Elevation 0.00 PSI 2000 SUBMITTAL SERIAL NO:4144HY1 09-20-2006 PAGE 1 MAMA MELLACES IN-RACK 6 HEADS@ 15 PSI+ .255/3000 ROOF PROOF CALC FLOW TEST RESULTS Water Supply STATIC 117 .00 PSI RESIDUAL 112 .50 PSI @ 1678.00 GPM CITY PRESSURE AVAILABLE AT 1560.3 GPM 113.07 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE ---------------- 100 38.43 25.50 8.00 23.07 101 32.32 25.50 8.00 16.32 102 32.25 25.50 8.00 16.25 103 32 .23 25 .50 8.00 16 .23 104 38.34 25.50 8.00 22.97 105 31. 38 25 .50 8.00 15 .39 106 31.31 25.50 8.00 15.32 107 31.29 25.50 8.00 15.30 108 38 .32 25.50 8.00 22.94 109 30.63 25.50 8.00 14.66 110 30.56 25.50 8.00 14.59 111 30 .54 25.50 8 .00 14 .58 113 30.06 25.50 8.00 14.12 114 29 .99 25 .50 8.00 14.05 115 29.97 25.50 8.00 14.04 117 29.65 25.50 8.00 13.73 118 29.58 25 .50 8.00 13.67 119 29.56 25 .50 8.00 13.65 121 29.37 25.50 8.00 13.48 122 29.30 25.50 8.00 13 .42 123 29 .28 25.50 8.00 13.40 125 29 .21 25.50 8.00 13 .33 126 29.14 25 .50 8 .00 13.27 127 29.12 25 .50 8.00 13.25 129 29 .13 25.50 8.00 13.26 130 29.06 25.50 8.00 13.20 131 29.05 25 .50 8.00 13.18 133 29.11 25.50 8.00 13.24 SUBMITI'AL SERIAL NO:4144HY1 09-20-2006 PAGE 2 MAMA MELLACES IN-RACK 6 HEADS@ 15 PSI+ .255/3000 ROOF PROOF CALC SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR -------- 134 29 .04 25 .50 8 .00 1 35 29.02 25.50 8 .00 70 22 .92 21. 68 5.60 71 22 .73 21 .68 5.60 72 22.67 21 .68 5.60 73 22.25 21.68 5.60 74 21 .75 21. 68 5.60 75 21.68 21 .68 5.60 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 4 OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 60 TO 70 PRESSURE -------- 13.18 13 .16 16.75 16 .47 16.39 15.79 15.09 14 .99 1060 .28 GPM 100.00 GPM 400.00 GPM 1560.28 GPM 58.66 PSI 0 .47 PSI 16.77 FPS SUBMITTAL SERIAL NO:4144HY1 09-20 -2006 PAGE 3 MAMA MELLACES IN-RACK 6 HEADS @ 15 PSI + .255/3000 ROOF PROOF CALC Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 72 75 1 .049 L 6.17 C=120 PT 14.99 ( 75) Q 21.68 F=0 F 0 .00 PE 0 .00 AO T 6 .17 0.1511 PF 0 .93 62 72DQ 22 .67 1.049 L 3 .25 C=120 PT 15.92 72) Q 44.35 F=T F 5.00 PE 0 .00 AO T 8.25 0.5678 PF 4.68 PT 20.60 62 ) ------------------ 71 74 1 .049 L 6.17 C=120 PT 15.09 74) Q 21 .75 F=0 F 0.00 PE 0.00 AO T 6.17 0.1520 PF 0.94 61 71DQ 22.73 1.049 L 3.25 C=120 PT 16 .03 71 ) Q 44.48 F=T F 5.00 PE 0.00 AO T 8 .25 0.5710 PF 4 .71 PT 20.74 61) ------------------70 73 1.049 L 6.17 C=l20 PT 15.79 73) Q 22.25 F=0 F 0 .00 PE 0.00 AO T 6.17 0.1585 PF 0 .98 60 70DQ 22.92 1.049 L 3 .25 C=120 PT 16 .77 70) Q 45.17 F=T F 5.00 PE 0.00 AO T 8 .25 0.5875 PF 4.85 • PT 21. 62 60 ) ------------------131 135 2.703 L 8.00 C=120 PT 13.16 (135) Q 29.02 F=0 F 0 .00 PE 0 .00 BN T 8.00 0.0026 PF 0.02 127 131DQ 29.05 2.703 L 8.00 C=120 PT 13.18 (131) Q 58.07 F=O F 0 .00 PE 0.00 BN T 8.00 0.0093 PF 0.07 123 127DQ 29.12 2.703 L 8.00 C=120 PT 13.25 (127) Q 87.19 F=0 F 0.00 PE 0.00 BN T 8.00 0.0197 PF 0 .16 119 123DQ 29.28 2.703 L 8.00 C=120 PT 13.41 (123) Q 116.48 F-=0 F 0.00 PE 0.00 BN T 8.00 0.0337 PF 0.27 115 119DQ 29 .56 2.703 L 8.00 C=120 l?T 13 .68 (119) Q 146 .04 F=0 F 0 .00 PE 0.00 BN T 8 .00 0.0513 PF 0.41 SUBMITTAL SERIAL NO:4144HY1 09-20-2006 PAGE 4 MAMA MELLACES IN-RACK 6 HEADS @ 15 PSI + .255/3000 ROOF PROOF CALC Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 111 115DQ 29.97 2.703 L 8.00 C=l20 PT 14.09 (115) Q 176.01 F=0 F 0.00 PE 0.00 BN T 8.00 0.0724 PF 0.58 107 lllDQ 30 .54 2 .703 L 8.00 C=120 PT 14.67 (111) Q 206.55 F=0 F 0.00 PE 0.00 BN T 8.00 0.0974 PF 0 .78 103 107DQ 31.29 2.703 L 8.00 C=120 PT 15.45 (107) Q 237.84 F=0 F 0 .00 PE 0.00 BN T 8.00 0.1264 PF 1.01 23 103DQ 32.23 2.703 L 19.75 C=l20 PT 16.46 (103) Q 270.07 F=T F 16.70 PE 0.00 BN T 36.45 0.1599 PF 5.83 13 23 2.703 L 1.83 C::::120 PT 22.29 23) Q 270.07 F=T F 16.70 PE 0.79 NR T 18 .53 0 .1599 PF 2 .96 PT 26.04 13) ------------------130 134 2.703 L 8.00 C=120 PT 13.18 (134) Q 29.04 F=0 F 0.00 PE 0.00 BN T 8.00 0.0026 PF 0.02 126 130DQ 29.06 2.703 L 8.00 C=120 PT 13.20 (130) Q 58.11 F=O F 0.00 PE 0.00 BN T 8.00 0 .0093 PF 0 ,07 122 126DQ 29.14 2 .703 L 8 .00 C=120 PT 13.27 (126) Q 87.25 F=0 F 0.00 PE 0 .00 BN T 8.00 0.0198 PF 0.16 118 122DQ 29.30 2.703 L 8.00 C=120 PT 13.43 (122) Q 116.55 F=0 F 0.00 PE 0 .00 BN T 8 .00 0 .0338 PF 0.27 114 118DQ 29.58 2.703 L 8 .00 C=120 PT 13.70 (118) Q 146.13 F=0 F 0.00 PE 0.00 BN T 8.00 0.0513 PF 0 .41 110 114DQ 29.99 2.703 L 8.00 C=l20 PT 14.11 (114) Q 176.12 F=0 F 0.00 PE 0.00 BN T 8.00 0 .0725 PF 0.58 106 ll0DQ 30.56 2.703 L 8.00 C=120 PT 14.69 (110) Q 206.69 F=0 F 0.00 PE 0.00 BN T 8 .00 0 .0975 PF 0.78 SUBMITTAL SERIAL NO:4144HY1 09-20-2006 PAGE 5 MAMA MELLACES IN-RACK 6 HEADS @ 15 PSI + .255/3000 ROOF PROOF CALC Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 102 106DQ 31.31 2.703 L 8.00 C=120 PT 15.47 (106) Q 238.00 F=0 F 0.00 PE 0.00 BN T 8.00 0.1265 PF 1.01 22 102DQ 32.25 2.703 L 19.75 Ci::120 PT 16.48 (102) Q 270.25 F=T F 16.70 PE 0.00 BN T 36.45 0.1601 PF 5.84 12 22 2.703 L 1.83 C=120 PT 22.32 22) Q 270.25 F=T F 16.70 PE 0.79 NR T 18.53 0.1601 PF 2.97 PT 26.08 12) ------------------ 129 133 2.703 L 8.00 C=l20 PT 13.24 (133) Q 29.11 F=0 F 0.00 PE 0.00 BN T 8.00 0.0026 PF 0.02 125 129DQ 29.13 2.703 L 8 .00 C=120 PT 13.26 (129) Q 58.24 F=0 F 0.00 PE 0.00 BN T 8.00 0.0094 PF 0.08 121 125DQ 29.21 2.703 L 8.00 C=120 PT 13.34 (125) Q 87.45 F=0 F 0.00 PE 0.00 BN T 8 .00 0.0199 PF 0.16 117 121DQ 29.37 2.703 L 8.00 C=120 PT 13.50 (121) Q 116 .83 F=0 F 0.00 PE 0.00 BN T 8.00 0.0339 PF 0.27 113 117DQ 29.65 2.703 L 8.00 C=120 PT 13.77 (117) Q 146.47 F=0 F 0.00 PE 0.00 BN T 8.00 0.0515 PF 0.41 109 113DQ 30.06 2 .703 L 8.00 C=l20 PT 14.18 (113) Q 176.53 F=0 F 0.00 PE 0.00 BN T 8.00 0.0728 PF 0.58 105 109DQ 30.63 2 .703 L 8.00 C=120 PT 14.76 (109) Q 207.17 F=0 F 0 .00 PE 0.00 BN T 8.00 0.0979 PF 0.78 101 105DQ 31.38 2.703 L 8.00 C=120 PT 15.54 (105) Q 238.55 F=0 F 0.00 PE 0.00 BN T 8.00 0.1271 PF 1. 02 21 101DQ 32.32 2.703 L 19.75 C=120 PT 16.56 ( 101) Q 270.87 F=T F 16.70 PE 0.00 BN T 36.45 0.1608 PF 5.86 SUl3MITTAL SERIAL NO :4144HY1 09-20 -2006 PAGE 6 MAMA MELLACES IN-RACK 6 HEADS @ 15 PSI + .255/3000 ROOF PROOF CALC Location Flow Pi pe Fittings Equiv Friction Pressure in Size & L~ngth Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 11 21 2 .703 L 1.83 C=120 PT 22.42 21) Q 270.87 F=T F 16.70 PE 0.79 NR T 18.53 0.1608 PF 2.98 PT 26.19 11) ------------------104 108 2 .703 L 8.00 C=l20 PT 22.94 (108) Q 38.32 F=0 F 0.00 PE 0.00 BN T 8.00 0.0043 PF 0.03 100 104DQ 38.34 2 .703 L 8.00 C=120 PT 22.97 (104) Q 76 .66 F=0 F 0.00 PE 0.00 BN T 8 .00 0.0156 PF 0.12 20 l00DQ 38.43 2 .703 L 19 .75 C=l20 PT 23 .09 (100) Q 115.09 F=T F 16.70 PE 0.00 BN T 36.45 0.0330 PF 1.20 10 20 2.703 L 1.83 C=120 PT 24 .29 20) Q 115 .09 F=T F 16.70 PE 0.79 NR T 18.53 0.0330 PF 0 .61 PT 25.69 10) ------------------61 62 2.203 L 9 .00 C=120 PT 20 .60 62) Q 44.35 F=0 F 0.00 PE 0.00 FM3 T 9.00 0.0153 PF 0.14 60 61DQ 44.48 2 .203 L 9.00 C=120 PT 20.74 ( 61) Q 88.83 F=0 F 0.00 PE 0.00 FM3 T 9.00 0.0553 PF 0.50 32 60DQ 45.17 2.203 L 39.75 C=l20 PT 21.24 ( 60) Q 134.00 F=2E F 9.60 PE -5.09 FM3 T 49.35 0.1184 PF 5.84 30 32 2.203 L 3.33 C=120 PT 21. 99 ( 32) Q 134 .00 F=0 F 0 .00 PE 0 .00 FMl T 3.33 0.1184 PF 0.39 8 30 2.203 L 5 .50 C;:;120 PT 22.38 ( 30) Q 134 .00 F=E,T F 16.40 PE 0 .00 FMl T 21.90 0.1184 PF 2.59 7 8 2.203 L 22.33 C=l20 PT 24.97 8) Q 134.00 F=E F 4.80 PE 9.68 FRl T 27 .13 0.1184 PF 3.21 ' ... SUBMITTAL SERIAL NO:4144HY1 09-20-2006 PAGE 7 MAMA MELLACES IN-RACK 6 HEADS @ 15 PSI + .255/3000 ROOF PROOF CALC Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 5 7 2 .203 L 2.00 C=l20 PT 37.86 7) Q 134.00 F=T F 11.60 PE 0.00 FRl T 13.60 0 .1184 PF 1. 61 PT 39.47 5) ------------------12 13 6 .357 L 12.50 C=120 PT 25.69 13) Q 270.07 F=0 F 0.00 PE 0.00 FM T 12.50 0.0025 PF 0.03 11 12DQ 270.25 6.357 L 12.50 C=120 PT 25.72 ( 12) Q 540.32 F=0 F 0.00 PE 0.00 FM T 12.50 0.0090 PF 0.11 10 llDQ 270.87 6.357 L 12.50 C=120 PT 25.83 ( l;I.) Q 811 .19 F=0 F 0.00 PE 0.00 FM T 12.50 0.0190 PF 0.24 6 l0DQ 115.09 6.357 L 93.67 C=120 PT 26.07 ( 10) Q 926 .28 F=2E F 25 .14 PE 0.00 FM T 118.81 0.0243 PF 2.89 5 6 6 .357 L 23.00 C=l20 PT 28.96 6) Q 926.28 F=0 F 0.00 PE 9.97 FR T 23.00 0 .0243 PF 0 .56 4 5DQ 134.00 6.357 L 1.00 C=120 PT 39.49 5) Q 1060.28 F=E F 12.57 PE 0.43 FR T 13 .57 0.0312 PF 0.42 2 4DQ 100.00 6.340 L 12.50 C=l40 PT 40.34 4) Q 1160.28 F=2E F 46 .22 PE 0.00 UN T 58.72 0.0281 PF 1. 65 1 2 5.914 L 95.00 C=l50 PT 41.99 2) Q 1160 .28 F=2E F 43.14 PE 0.00 UN T 138.14 0 .0347 PF 4 .79 0 1 5 .914 L 40.00 C=lS0 PT 46.78 1) Q 1160 .28 F=T,GV,4E/DCA F 137.12 PE 0.00 UN T 177.12 0.0347 PF 6.15 6 11 DOUBLE CHECK DETECTOR ASSEMBLY 5.75 PT 58.68 ( 0) MATERIAL DATA SUBMITTAL MAMA MELLACE'S IN-RACKS 6195 EL CAMINO !<EAL CARLSBAD, CA LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DRIVE, STE. F OCEANSIDE, CA 92056 760-806-9997 • 760-806-4813 FAX ® SLOW CLOSE Approved by: NYC Board of Stds. & Appeals, Cal. #996-81-SM (175psi) 720-83-SA (350 & 500 psi) BRONZE BUTTERFLY VALVE ONE-PIECE, FULL-PORT 175 PSI THREADED ENOS DIMENSIONS Valve Size DIM 1" 1-1/4" 1-1/2" 2" 2-1/2" A 2.13 2.63 2.88 3.25 4.13 B' 3.16 3.31 3.41 3.63 3.82 C 1.56 1.94 2.19 2.75 3.19 D 1.72 2.11 2.38 3.07 3.50 J 4.16 4.16 4.51 4.76 4.66 K .66 .73 .73 .79 1.18 L .83 .90 .10 1.41 1.29 M-40' 1.10 1.38 1.61 2.07 2.47 ~ .96 1.28 1.50 1.94 2.32 N-AO' 2.25 2.00 2.50 2.25 10.00 .... 1.13 1.25 1.41 ALL DIMENSIONS-INCHES ' Pertains to BB-SC100 only. 1.69 1.75 ' Pertains to BB-SCS02 only. 'M-40 ARE DIMENSIONS USING SCHEDULE 40 PIPE 'M-80 ARE DIMENSIONS USING SCHEDULE 80 PIPE 'N-40 IS FLOW RESISTANCE EXPRESSEDIN EQUIVALENT LENGTH OF SCHEDULE 40 PIPE 'W IS THE WRENCH MAKE-UP LENGTH FEATURES • Slow opening and closing • Quarter tum operation • Water Hammer elimination • Optional internal tamper switch (Indoor/Outdoor use). -Signals disc movement -Factory or Field installation -10 Amp / 115 VAC-60 Hz -o.5 Amp 12s voe • Grooved Ends Available in Sizes 2" and 2-1/2" MATERIALS LIST ITEM PART 1 Indicator 2 Housing 3 Body 4 Handle 5 Disk 6 Disk Seal MATERIALS Iron Bronze Brass Stainless Steel EPDM 7 Sw itch Housing . (BB-SCS02) Aluminum <8> ~s APPROVED - ASTM SPEC. F0008P ASTM 584 UNS C8440 ASTM B176 UNS C85800 ASTM A276, Type 304 o--- BB-SC100 Sizes 1", 1-1/4", 1-1/2", 2", 2-1/2" --4-1/2''-' ---; 1-----0 BB-SCS02 (Includes Switch) The information presented on this sheet is correct at the time of publication. Milwaukee Valve reserves the right to change design, and/or material specifications without notice. For the most current information access www.milwaukeevalve.com MILWAUKEE VALVE Schedule-10·/Schedu le-40· Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-I O/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-I O/Schedule-40 gives you the extra quality assurance you demand. Our Sch-IO (1 1~ "-8") pipe and Sch-40 ( l "-2 ~ ") pipe have passed the same thorough lab tes~g as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Schedule-I O/Scbedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Superior Coating Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube &_Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. American Made Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Specifications & Approvals Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of300 psi maximum and also meet the stringent requirement for the following tests: • Welded Outlets • Hydrostatic Pressure • Side Wall Rupture • Vibration Test NPS tn;mm 1' 25 1¼' 32 1½' 40 2' 50 2½" 65 NPS ln;mm 1" 25 1¼" 32 1½' 40 2" 50 2½" 65 3" 80 4' 90 5' 125 6" 150 8' 200 1:qca I Row Control ~ allied TUBE & CONDUIT Sch-40 Specifications Nominal 1.0. Wt. Wt. (H20 Filled) PCS/ WI/lift (21 ') WI/lilt (24') WI/lift (26' ln;mm lbs/Ft; Kglm lbs/Ft; Kglm lift lbs; Kg lbs; Kg Lbs; Kg 1.049 1.680 2.05 70 2,470 2,822 -2,940 26.6 2.5 3.05 70 1,120 1,280 1,334 1.380 2.270 2.93 51 2,431 2,778 2,894 35.1 4.36 4.36 .51 1,103 : 1,260 1,313 1.610 2.720 3.61 44 2,513 2,872 2,992 40.9 4.0 5.37 44 ·1, 140 1,303 1,357 2.067 3.650 5.13 30 2,300 2,628 2,738 5?5 5.4 7.63 30 1,043 1,192 1,242 2.469 5.790 7.86 19 2,310 2,640 2,750 62.7 8.6 11.73 19 1,048 1,197 1,247 Sch-10 Specifications Nominal 1.0: Wt. Wt. (H20 FIiied) Pcs/ WI/lift (21 ') Wt/Lift (24') WI/lift (25' ln;mm Lbs/Ft; Kg/m Lbs/Ft; Kg/m Lift Lbs; Kg lbs; Kg lbs; Kg 1.097 1.400 1.81 91 2,675 3,053 3,185 27.9 2.1 2.70 91 1,213 1,385 1,445 1.442 1.810 2.52 61 2,319 2,664 2,760 36.6 2.7 3.75 61 1,052 1,208 1,252 1.682 2.080 3.04 61 2,664 3,045 3,172 42.7 3.1 4.52 61 1,208 1,381 1,439 2.157 2.640 4.22 37 2,051 2,344 2,442 54.8 3.9 6.28 37 930 1,063 1,108 2.635 3.530 5.89 30 2,224 2,542 2,648 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 108.2 8.3 17,53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1,951 2,230 2,322 161.5 13.8 34.27 10 885 1,012 1,053 8.249 16.490 40.15 7 2,424 2,770 2,885 209.5 24.5 59.75 7 1,100 1,256 1,309 @ <8> @i9 Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 Customer Service: (800) 882-5543 Fax 708-339-1806 11350 Norcom Rd.• Philadelphia, PA 19154 2525 N. 27th Ave. • Phoenix, AZ 85009 S5 -3 Dyna-Flow® High Strength Steel Pipe The original high-strength 1/ghtwall sprinkler pipe with hydraulics superior to Schedule-10. Dyna-Flow pipe is the "original" high- strength lightwall sprinkler pipe. Dyna- Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-I 0 pipe. Lightweight, easy to cut and easy Specifications NPS Nominal I.D. Wt. Wt. (H20 FIiied) Pcs/ wwn (21·1 ww11 (24') VMJ11(25' ln;mm /n;mm Lbs/Ft; Kglm Lbs/Ft; KQ!m Lift Lbs; Kg Lbs; Kg Lbs; Kg to handle for installation. Dyna-Flow is a valuable addition to any fire protection system. Superior Hydraulics 1' 25 1¼' 32 1½' 40 2' 1.191 30.3 1.536 39.0 1.728 43.9 2.203 0.830 1.31 1.2 1.95 1.059 1.87 1.6 2.78 1.667 2.71 2.5 4.03 2.104 3.79 With ~ inside diameter of up to 11 % larger than Schedule-40 and up to 7% larger than Schedule-I 0, Dyna-Flow pipe hydraulics are exceptional. Larger 1.D.s enable Dyna-Flow, and related components, to be down-sized within the system, thus increasing the potential for job cost savings. For complete Hazen- Willian'ls charts, refer to ''Dyna-Flow Hydraulic Data Tables." 50 2½' 65 3' 80 4' 90 56.0 2.703 68.7 3.314 84.2 4.310 109.5 3.1 5.64 2.564 5.10 3.8 7.59 3.387 7.18 5.0 10.69 4.473 10.86 6.7 16.16 Coatings & Fabrication Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special proces11 or equipment needed for fubrication and installation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF'. In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset ofMicrobiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Specifications & Approvals Dyna-Flow/Super Flo pipe is manufac- tured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo arc UL Listed, FM Approved and ULC Listed. ®<&>@ Listed Approved Listed Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna- Flow/Super Flo is now available "hot- qip" galvanized and has been specifically approved by FM for dry systems uses. 91 1,586 1,812 1,888 91 119 822 856 61 1,356 1,550 1,615 61 615 703 733 61 2,135 2,440 2,542 61 968 1107 1153 37 1,634 1,868 1,946 37 741 847 883 30 1,615 1,846 1,923 30 733 837 872 19 1,351 1,544 1,608 19 613 700 729 19 1,784 2,039 2,124 19 809 925 963 Additional Benefits • Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. • Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. • Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. • Fast cutting and welding, as well as easy roll grooving and end preparation. • Available in Factory roll grooved form for quicker shop turparound. • Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. 1:qca I Row Control (;) allied 16100 S. Lathrop• Harvey, IL 60426 Customer Service: TUBE & CONDUIT 11350 Norcom Rd. • Philadelphia, PA 19154 2525 N. 27th Ave. • PhQenix, ~ 85009 (800) 882-5543 Fax 708-339-1806 S2 -3 ' .. ' Anvil® Cast Iron Threaded and Flanged Fittings AnvilStarTM offers the most complete line of Casi Iron and Malleable Iron Threaded Fittings in the industry. Our versatile range of fittings is designed lo provide dependable, fire-roted service. Cost Iron Threaded Fittings, are manu- factured in accordance with ASME B 16.4. They are UL listed and FM Approved and ore ovoiloble in sizes 1/," NPS through 12" NPS. PROJECT INFOR~lATION: Project: Data: I Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: ', e I ®<a>~ APPROVED APPROVAL STM1P: 3/05 • 100 For the latest UUULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvllstar.com or contact your local AnvllStar representative ~taulic· IPS CARBON STEEL PIPE 07 01 GROOVED FITTINGS ·, • Grooved End Fittings PRODUCT DESCRIPTION @ ~ <S> See Vlctaullc publlcaUon 10.01 lot details. Victaulic offers a broad line of fittings in sizes through 48" (1200 mm) in a variety of straight and reducing styles. Most standard fit- tings are cast of durable ductile iron to precise toler- ances. Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings are supplied with grooves or shoulders to permit fast installation without field preparation. The grooved design per- mits flexibility for easy alignment. These fittings are not intended for use with Victaulic couplings for plain end pipe (refer to Sec- tion 14.04 for fittings avail- able for plain end applications), Fittings are provided in var- ious materials including malleable iron, ductile irqp, steel or segmentally welded steel depending on styles and size. Fittings ate painted orange enamel with galvanized optionally available, contact Victaulic for details. Victaulic fittings are designed specifically for use in grooved piping sys- tems. Fittings are provided grooved or with shoulders conforming to standard steel pipe outside diame- ters. When connecting wafer or lug-type butterfly valves directly to Victaulic fittings with 741 or 743 Vic- Flange~ adapters, check disc clearance dimensions with I.D. dimension of fitting. -.o Stainless Steel -Grooved end fittings are available in Schedule 10 'fype 316 stainless steel (Schedule 5, 40 and Type 304 optionally available) in various sizes. Fitting center-to-end dimensions will vary depending upon type and schedule. Refer to Section 17.04 and 17.16 for details. Aluminum -Grooved end fittings are available in alu- minum alloy 356 T6, in sizes from 1 -8 • (25 -200 mm). Refer to Section 21.03 or contact Victaulic for details. Alternate Styles Extra Heavy EndSeal~ "ES" Fittings -EndSeal fittings are available in 2 - 12' (50 -300 mm) for use with "ES" grooved pipe and HP-70ES EndSeal or Fire-R"" couplings. "ES" fit- tings are painted green for easy identification. EndSeal (and standard) fittings may be easily intem.ally coated (by others) for severe ser- vice requirements. Always specify "ES EX?,dSeal flt- .,. tings" when ordering. See Section 07.03 for informa- tion on EndSeal fittings. Vlctaullc Company of America Phone: 1-800-PICK-VIC (1-800-742-5842) Fax: 61()..250-a817 e-mail:plcxvic@victaullc.com 1449 Rev,.H 1/03 Fittings Machined for Rubber or Urethane Lin- ing (MRL) -For severe abrasive services, Victaulic fittings may be rubber or urethane lined (by others). Lining may be inside diam- eter/end (abrasion resis- tance) or wrap-around (corrosion and/or abrasion) machined. Refer to Section 25.03 or contact Victaulic for specific details. FOR ABRASION RESISTANCE ONLY R~Qdo 0.0, C E 0.030' R FOR CORROSION AND/OR ABRASION RESISTANCE Exaggerated for clarity VICTAULIC-IS AN ISO 9001 CERTIFIED COMPANY Vlctaullc Company of Canada Phone: 416-675-5575 Fax: 416-675·5565 e-mail: vlccanada@viclaulic.com ~ Registered Tredemark ol V,c:taulic Vlctaullc Europe Phone:32-9-381-1500 Fax: 32-9-380-4438 e-mail: vlceuro@vlclaulic.be Vlctaullc America Latina Phone: 610-559-3300 Fax: 610-559-3608 e-mail: vlcal@vlclaullc.com C Copyright 2003 Vlctaullc Vlctaullc Asia Pacific Phone: 65-6235-3035 Fax: 65-6235-0535 e-mail: vlcap@vlctaullc.com Prlntod In U.S.A. - ~taulic· IPS CARBON STEEL PIPE 1 Q 02 FIRE PROTECTION PRODUCTS • @ Plus Style 005 FireLockTM et System '"""' ,, .. ouu Rigid Coupling with Vic-Plusru Gasket System PRODUCT DESCRIPTION £xs,u;;srstsd for Clarity DIMENSIONS ~vMl~z~ ~00 Rated for wet and dry sprinkler systems at 350 psi (2413 kPa) for 1 ¼ • 4 • (32 • 100 mm) sizes and 300 psi (2068 kPa) for 4¼ • 8' (108 • 200 mm) sizes; Schedule 10 roU grooved or Schedule 40 cut or roU grooved steel pipe. Style 006 is rigid and does not accommodate expansion, con· traction or angular deflection. Vlctaullc Cc;>mpany of America Phone: 1·800-PICK-VIC (1-800-742·5842) Fax: 61 D-250-8817 e-mall:plckvic@vlctaullc.com FireLock™ Style 005 rigid coupling bas a unique, pat- ented angle-pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. The FireLock couplings Sprinkler Systems. Angle- pad design permits assem- bly by removing one nut/ bolt and swinging the housing over the gasket. This reduces components to handle during assembly; speeds and eases installa - tion on pipe grooved to Victaulic specifications. provide rigidity for valve Style 005 FireLock cou- connections, fire mains and plings with the Vic- long straight runs. Support Plus TM Gasket System and hanging requirements are designed and rec- correspond to NFPA 13 ommended for use ~qu~ta~ [~] ( V dS) ~8;~,8~n! :~;8 ~pproved. publication 10.01 for details. Pipe Size Nominal Actual Max. Max. Allow. Outaldo Outaldo Work. . End Pipe End O Bolt/Nut Diameter Diameter Presa.§ Load Sep,t No.• Size Inches/mm lnchea/mm PSl'lkPo Lbs.'/N lnJmm Inches/mm 1¼ 1.660 350 755 0.05 2-¼ X 2 32 42,4 2413 3370 1,2 1½ 1.900 350 990 0.05 2-¼X 2 40 48,3 2413 4415 1,2 2 2.375 350 1550 0.07 2-¾X 2½. so 60,3 2413 6900 1,7 2½ 2.875 350 2270 0.07 2-¼ X 2½ 65 73,0 2413 10110 1,7 76,1 mm 3.000 350 2475 O.o? 2 • ¼ X 2½ 76.1 2413 11010 1.7 3 3.500 350 3365 0.07 2-¼ X 2½ 80 88,9 2413 14985 i ,7 4 4.500 350 5565 0.16 2 -¼-X 2½ 100 f14.3 2413 24770 4.1 108,0 mm 4.250 300 4255 0.16 2 ·¼ X 2½ 108,0 2068 18940 4.1 5 5.563 300 .7290 0.16 2·½X2¼ 125 141,3 2068 32445 4. 1 133,0 mm 5.250 300 6495 0.16 2-½X2¼ 133,0 2068 28900 4,1 139,7 mm 5.500 300 7125 0.16 2-½X2¾ 139.7 2068 31715 4, 1 6 6.625 300 10340 0.16 2-½X2¼ 150 168,3 2068 46020 4,1 159,0mm 6.250 300 9200 0.16 2-¾ X4¼ 159,0 2068 40955 4, 1 165,1 mm 6.500 300 9955 0.16 2-½X2¾ 165,1 2068 44295 4,1 8 8.625 300 17525 0.19 2 • '¼ X 4¼ 200 219,1 2068 78000 4,8 @ § t Refer to no1es on page 2. VICTAULlce IS AN ISO 9001 CERTIFIED COMPANY ONLY on fire protection systems. Vic-Plus Gasket System: Victaulic9 now offers a gas- ket system which requires no field lubrication. The Vic-Plus™ System (patent pending) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over-lubrication. Dimensions Inches/mm Aprx. Wgt. Ea. X y z LbI./kg 2.75 4.50 1.88 1.2 70 114 148 0,5 3.00 4.75 1.88 1.2 76 121 148 0,5 3.50 5.25 1.88 1.6 89 133 148 0,7 4.00 5.75 1.88 1.9 102 146 148 0,9 4.13 5.75 1.88 1.9 105 146 148 0.9 4.63 6.13 1.88 2.1 118 158 148 1,0 5.75 7.25 2.13 3.1 146 184 54 1.4 5.63 7.25 2.13 3.1 143 184 54 1,4 6.88 9.00 2.13 4.5 175 229 54 2,0 6.63 9.00 2.13 4.5 168 229 54 2,0 6.88 9.00 2.13 4.8 175 229 54 2.2 8.00 10.00 2.13 5.0 203 254 54 2,3 7.63 10.00 2.13 5.5 194 254 54 2,5 8.15 10.00 2.13 5.5 207 254 54 2,5 10.50 13.13 2.63 11.3 267 334 67 5, 1 Vlctaullc Company of Canada Phone: 416-675-5575 Vlctaullc Europe Phone:32·9-381-1500 Fax: 32-9-380·4438 Vlctaulle America Latina Phone: 610-559-3300 Vlctaullc Asia Pacific Phone: 65-235-3035 Fax: 416-675-5565 e-mail: viccanada@victaulic.com e-mail: viceuro@victaulic.be Fax: 610-559-3608 e-mail: vical@victaulic.com Fax: 65-235-0535 e-mail: vicap@victaulic.com 1538 Rov.E 10/00 e Registered Trademarl< of Vlctaullc Q Copyright 1999 Vlctaullc Pnnted In U.S.A. MATERIAL SPECIFICATIONS Housing: Ductile iron conform- ing to ASTM A-396, grade 65- 46-15, and ASTM A-536, grade 66-46-12. Housing Coating: Orange enamel 0 Optional: Hot dipped galva- nized Gasket: 0 Gra.de "E" EPDM • Type A Vic-Plus Gasket System t (Violet color code): FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler ser- vices up to the rated working pressure using the Grade "E" Type A Vic-Plus Gasket System, requiring no field lubrication. For dry services, Victaulic continues to recommend the use of Grade "E" Type A FlushSeal• Vic-Plus Gasket System. Contact Victaulic for details. Bolts/Nut■: Heat treated car- bon steel, zinc electroplated to ASTM B-633; Track head bolt conforming to ASTM A-183 minimum tensile 110,000 psi (758340 kPa); Flanged hex nut conforming to ASTM A-563, Grade A. t Standard gasket and FlushSeal gasket approved for dry pipe systems to -40°F (-40°C). Supplemental lubrlcanl is rec- ommended lor services· Installed at or continuously operallng-below o•F (-18°C). Vlctaullc continues to recom- mend the use of FlushSeal gaskets for dry services. The information provided below is based on the latest listing and approval data at the time of publication. Listings/ Approvals are ·suJ:,ject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Rated Workl(lg Preaaure Rated Working Pre11ure PSI Pipe Size Schedule lnchee UL 5 1¼-3 175 1¼-4 350 10, 40 5-8 300 BLT 1¼ -2 300 1-¼-4 300 DF 6 175 OT 1¼-2 300 EL 1¼-2 300 NOTES: 6 refers to Listed/ Approved Schedule 6 steel sprinkler pipe. 10 refers to Listed/ Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. BLT refers to Listed/Approved steel sprinkler pipe manufactured by Amedcan Tube Company. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. • DT refers to Listed/ Approved Dyna Thread steel sprinkler pipe manufactured by American Tube Company. PSI Pipe Size ULC FM Schedule lnchee UL ULC FM 175 175 4 EZ 350 350 6 300 300 SF 1¼-4 300 300 Super 40 1¼-2 300 300 TL 1¼ -2 175 175 WLS 1¼-2 300 300 XL./XL-11 1¼-3 300 300 EL refers to Llsted/ Approved Eddylite steel sprinkler pipe manufactured by Bull Moose Tube Co. EZ refers to Listed/Approved EZ-Flow steel sprinkler pipe manufactured by Northwest Pipe & Casing Co. SF refers to Llsted/ Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. SL refers to Usted/ Approved steel sprinkler pipe manufactured by Western Tube and Conduit Corporation. 300 300 300 175 175 175 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 Super 40/XL refers to Listed/ Approved Super 40 or Super XL steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. WLS refers to Listed/Approved steel spdnkler pipe manufactured by Wheatland Tube Company. XI/XL-II refers to Listed/ Approved XL or XL-II steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. NOTES • Worklng Pressure and End ~oad are total, from all Internal and external loads. based on standard weight {ANSI) steel pipe, standard roll or cut grooved In accor- dance with Victa~llc specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Wor:king Pressure may be Increased to 1 ½ times the figures shown. t For field Installation only. FlreLock Style 005 cotiplings are essentially rigid and do not accommodate expansion/contraction. C Number of bolts required equals number of housing segments. Metric thread size bolts are available { color coded gold) for all coupling sizes upon request. Contact Vlctaullc for details. § Style 005 couplings are VdS and .LPC Approved to 12 Bar (175 psi). WARNING: Piping systems must always be depressurlzed and drained before attempting disassembly and removal of any Vlctaullc piping products. Thia product shalt be manufactured by Vlctaultc Company. All produc1s shall be lnslalted In acc0<dance with current Vlcteullc lnstelletlorvessembly Instructions. Vlctaullc reserves the right to cnange product specifications. designs and slandard equlpmen1 wlthoul notice and without Incurring obllgallons. 10.02-2 . --. '--" '-...../ ~taulic· IPS CARBON STEEL PIPE 11 02 HOLE CUT PRODUCTS • Styles 920 and 920N Mechanical-T® Bolted Branch Outlets PRODUCT DESCRIPTION Styles 920 and 920N Style 920 Cross See Victaullc publication 10.01 for details. See chart on page 4 for pressure ratings. Victaulic Mechanical-T® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position perma- nently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size con- nections. NOTE: Style 920 and Style 920N housings cannot be mated to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Spec- ify choice on order. Units are supplied painted with plated bolts. Galvanized housings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi (3450 kPa) working pressure on~steel pipe. They may also be used on high density poly- ethylene or polybutylene (HDPE) pipe. Pressure rat- ings on HDPE are dependent on the pipe rating. Contact Victau!ic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechani- cal-T Styles 920 and 920N must be installed so that the main and branch connec- tions are a true 90° angle when permanently attached to the pipeline surface. MATERIAL SPECIFICATIONS Vlctaullc Company of America Phone: 1-800-PICK-VIC (1-800-742-5842) Fax: 610-250-8817 e-mall:pickvic@victaulic.com 1480 Rev. E 11/00 Housing/Coating: Ductile iron conforming to ASTM A-395, grade 65-45-15, and ASTM A· 536, grade 65-45-12, with orange enamel coating. 0 Optional: Hot dipped galva- nized Gasket: (Specify choice*) 0 Grade "E" EPDM EPDM (Green color code). Temperature range -30°F to +230°F (-34°C to+ 110°C). Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemi- cal services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F ( +30°C} and hot +180°F (+82°C) NOT RECOMMENDED FOR PETROLEUM SERVICES. 0 Grade "T" nitrile Nitrile (Orange color code). Temperature range -20°F to +180°F (-29°C to +82°C). Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified tempera- ture range. Not recom- mended for hot water services over + 150°F ( +66°C) or for hot dry air over + 140°F (+60°C). VICTAULIC-IS AN ISO 9001 CERTIFIED COMPANY *Services listed are General Ser- vice Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Refer- ence should always be made to the latest Victaulic Gasket Selection Guide for specific gas- ket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: (Styles 920 and 920N) Heat treated carbon steel zinc plated to ASTM B-633, track-head conforming to physi- cal properties of ASTM A-183 minimum tensile 110,000 psi (758340 kPa). Victaulic Company of Canada Phone: 416-675-5575 Victaulic Europe Phone:32-9-381-1500 Fax: 32-9-380-4438 Vlctaulic America Latina Phone: 610-559-3300 Victaullc Asia Pacific Phone: 65-235-3035 Fax: 416-675-5565 Fax: 610-559-3608 Fax: 65-235-0535 e-mail: viccanada@victaulic.com e-mail: viceuro@victaulic.be e-mail: vical@victaulic.com e-mail: vicap@victaulic.com llO Registered Trademark of Vlctaulic C Copyright 1999 Victaulic Printed in U.S.A. Fig. 69 -Beam Clamp Retaining Strap Component of State of California OSHPD Approved ® ® Seismic Restraints System C Size Range -3/8" thru 7/8" rod by 4" thru 16" length.* Function -To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (1999) 6-4.7.1 . Important Note -Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mecha- nism of some kind such as a hex nut or the beveled locking slot on the TOLCO™ Fig. 69R will provide a more secure reliable installation. Approvals -Underwriters' Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load. spacing and placement information relating to OSHPD projects, please refer to the IOLCO Seismic Restraint Systems Guidelines. Finish -Pre-Galvanized Order By -Figure number, type, length "B" and rod size being used with beam clamp Note -Minimum return on Strap: 1 ". Dimensions • Weights Type Rod Si;i:e A Hole Size B 3/8 7/1 6 Specify 1/2 9/1 6 Specify 2 5/8 11/16 Specify 3/4 13/1 6 Specify 3 3/8 -7/8 Specify Specify • Longer lengths are available, consult factory. OFFICE/MANUFACTURING FACILITY• 1375 SAMPSON AVE.• CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800. 786.5266 • ® TDLCO www.trJlc:ri wm _ rNIBCO Rev1s10 11 ~,22•i 0(J1 Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 1¼" Throat Openings Size Range -(Fig. 65 and Fig. 66) 3/8", 1/2" and 5/8" rod Material -Carbon Steel with hardened cup point set screw and jam nut Function -Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 1'/." (Fig. 66). Features -All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bot- tom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals -Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-171E, Type 23 and Manufacturers Standardization Society SP-69, Type 19. Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish -Plain Note -Available in Electro-Galvanized and HDG finish. Order By -Figure number, rod size and finish Fig. 65 Patent #4,570,885 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1'/,e 3/4 7/16 610 28 1/2 11/2 3/4 9/16 1 '/, 1130 55 5/8 1½ 3/4 9/16 1 'I. 1130 55 • Max. loads for clamp with set screw In up or down position. Fig. 66 Dimensions • Weights Rod Size Max, Rec. Approx. A B C D E F Load Lbs,* Wt./100 3/8 1 '/,e 1 '/• 7/16 610 28 1/2 1½ 1 '/. 9/16 1 '/. 1130 55 5/8 1½ 1 •,. 9/16 1¼ 1130 55 • Max. loads for clamp with set screw In up or down position. Component of State of ~ California OSHPO Approved ~ Seismic Restraints System ®c@ C ■ OFFICEIMANUFACl\.lRING FACILITY• 1375 SAMPSON AVF.. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800. 786.5266 WWW.lolCGc:om INCORPORATED CORONA. CA• (909) 737-5599 , ' ' • I•• ' 'l•• ' I '' •• 1 1 ' '.,, ;° ~ I, ' 1 I ! ' ' \ l .,,.-, I 1 1 • ' -',. ••• • • • • • '1 , ' •• ' FIG. 51 AND FIG . 52 SIDE BEAM BRACKETS (CONT.) A I FIG . 51 FIG. 52 FJG. 51 for NFPA Rod and Fastener S izing APPROX. PIPE ROD HOLE SIZE STOCK WEIGHT SIZE SIZE A B C H-1 H-2 SIZE PER 100 1/2 -2 3/8 2 3/4 2 7/16 7/16 3/16x2 35 ~i;Mi:;;,i'§:j;.J;~t~,1;:;;~i.~~:J?z;t~:,,l;~, .sf.4,i .. ,:;, .. ~;.,;, <:~t:::,;:::·.:Li·~~f J§.:~,i.i·-,.:;za 9.i .. ,:-"', .... ~ .:'. .. 'i .•. 'r-;u12.~,;t-;;_;,;i&i1i.:.ili~.~1:~i:.\..:,l,·1 5-6 1/2 2-1/2 3/4 2-1/2 9/16 9/16 3/8x2-l/2x2-l/2 71 .. ;~1\~:;.:?>·',-,:•:}:1,rn.·;;;;:~; .• ~~~v~,,-: :;:'· 'x 3/4.:r, • .. : ·,: . .g::iLK .=,:· ,-·.:-i i11.f ... :·. 9/..lci : :.-·: • ......... 3/~~iJ/~~,,1;2 ,,r ::,.-':'.;.;· 70:~, ~-/:.;;:~ FIG. 52 • 6 Hole Bracket ROD SIZE 3/8xl/2 A 2 B C 1-1/16 2 HOLE SIZE H-l H-2 H-3 9/16 7 /16 9/32 STOCK SIZE 3/16x.2 APPROX. WEIGHT PER 100 35 FIG. 56 TAPPED SIDE BEAM CONNECTOR Size Range • 1/2 thru 4 inch pipe (3/8 inch rod). Material • Carbon Steel Function · Practical and economical bracket used to support hangers from steel or wood beams. Can be used with concrete shot-type inserts. Tapped hole allows easy adjustment of hanger rod. Approua/s • Underwriters' Laboratories listed and Factory Mutual Engineering approved for 1/2 • 4" pipe. Fin ish • Plain, Electro-Galvanized, HOG, and Stainless Steel. O rder By -Figure number and finish. Note -Per NFPA #13: 1/2 thru 2 inch pipe use 3/8 inch fastener; 2-1/2 thru 4 inch pipe use 1/2 inch fastener. PIPE SIZE ROD SIZE A B C D E 1/2 • 4 2-5/8 3/8 1 3/8 1-1/16 HOLE SIZE F G H 1-1/8 7 /16 9/16 IT A u G H tj ~ APPROX, STOCK WEIGHT J SIZE PER 100 1-1/4 1/4xl 20 C 4 l ~-. rlo INCORP.ORAJED 53 CQAONA, CA •-(909) 7~7-6599 ~~a&l~,.· ... ---~A·~.:.,.lthlMIMNt .... r::rrr I ' • ' ' • • • ,( " • .I• • ,• • o _, • • :' • ~, • • • • " -•• ,1 .. ' : .• • • ••• ' • • • • . ---. FIG. 99 ALL THREAD ROD CUT TO LENGTH Size Range • 3/8 thru 7 /8 Inch rod in 1 inch increments, Material -Carbon Steel Maximum Temperature -750°F Finish . Plain, Electro-Galvanized, and Stainless Steel, Order By . Figure number, rod · diameter, rod length, and finish. FIG . 100 ROD SIZE 3/8 1/2 5/8 3/4 7/8 MAX. REC. LOAD LBS, FOR SERVICE TEMPS. 650'F 750'F 610 540 1130 1010 1810 1610 2710 2420 3770 3360 ALL THREAD RbD FULL LENGTHS Size R'ange • 1/4 thru 1-1/2 inch rod in 10'-0" lengths. Material • Carbon Steel Maximum Temi,erature -750°F Finish -Plain,. El°ectro-Galvanized, and Stainless Steel. Order By -Figure number, rod diameter, and finish. MAX. REC. LOAD.LBS. APPROX. ROD FOR SERVICETEMPS WEIGHT SIZE 65D'F 75D'F PER 100 FT. INCORf'O"ATeo CORONA. CA t (909) 737,ti599 I • • '• • • • ' ,,.• • • t ' _':. ' • • ' • • • • FIG. 2 ADJUSTABLE RING HANGER 15 FIG. 2 NFPA ADJUSTABLE RING HANGER WITH REDUCED ROD SIZE Size Range • 1/2 thru 6 inch pipe. Material. Carbon Steel, Mil. Galvanized to G-90 specification. Function , For general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Spring tension on swivel nut holds it securely in hanger before installation. Swivel nut easily removed. Approvals. Underwriters' Laboratories listed and Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-171E, type 10, and Manufacturers Standardization Society SP-69, type 10. Maximum Temperature • 6S0°F Finish • Mil. Galvanized and Stainless Steel. Order By • Figure number and pipe size. PIPE SIZE ROD SIZE A B •3/8" nut 11 und when NF'PA rod sl~ing is requested, C A STOCK SIZE MAX. REC. LOAD LBS. C APPROX. WEIGHT PER 100 F'IG. 2 FIG. 2 NFPA ,. ® • www.tolco.com TOLCO ' -Rev1s1on2/10/2006 a d IHdllll of NIBCO' Fig. 980 -Universal Swivel Sway Brace Attachment Size Range -One size fits bracing pipe 1" thru 2", TOLCO 12 gauge channel, and all structural steel up to 1/4" thick. Material -Carbon Steel Function -Multi-functional attachment to structure or Component of State of Calllomla OSHPD Approved Seismic Restraints System braced pipe fitting. Features -This product's design Incorporates a concentric H attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2002) Figure 9.3.5.9.1 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation -The Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It Is intenqed to be combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 2002, 4L, 4A or 48 to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install -Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until set bolt head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals -Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note -The Fig. 980 Swivel Attachment and the Fig. 1001, Fig. 1000, Fig. 2001 or Fig. 4A Pipe Clamp make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters' Laboratories and the National Fire Protection Association (NFPA) Finish -Plain Note -Available in Electro-Galvanized finish. Order By -Figure number and finish. Patent #6,273,372 A B 5¼ Dimensions • Weights H* Max. Design Load Lbs. 17/32 2765 Approx. Wt./100 132 • Available with hole sizes to accommodate up to 3/4" fastener. Consull factory. Lateral Brace TOLco® brand bracing components are desgined to be compatible QHJ.Y with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER -NIBCO does HQI warrant against the failure of TOLco® brand bracing components, in the Instance that such TOLCO® brand bracing components are used In combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall HQI be liable under any circumstance for any direct or indirect. incidental or consequential damages of any kind. Including but not limited to loss of business or profit. where non-TOLCO brand bracing components have been. or are used. OFFICE/MANUFACTURING FACILITY• 1375 SAMPSON AVE.• CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE• 800.766.5266 www.tolco.com ■ ® TQLCO www.tolco.com . •NIBCO Rev1s1on 2/1012006 Fig. 1000 -"Fast Clamp" Sway Brace Attachment Size Range -Pipe size to be braced: 1" thru 6" Schedule 10 thru 40 IPS. • Pipe size used for bracing: 1" and 1 ¼" Schedule 40 IPS. • Additionally (UL) approved for use to brace Schedule 7 sprinkler pipe up to 4" (maximum horizontal design load 655 lbs.) Torque requirement 6 -8 ft. lbs. Material -Carbon Steel Function -For bracing pipe against sway and seismic disturbance. Features -Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a 4-way riser brace. Can be used as longitudinal brace with Fig. 907. Comes assembled and individually packaged with illustrated installation instructions -sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Installation -The Fig. 1000 is the "braced pipe" attachment component of a lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attach- ment component, Fig. 980, 910 or 909 to form a complete brac- ing assembly. Follow NFPA 13 and/or OSHPD guidelines. To Install -Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. Tighten hex nuts until leaf spring is flat. It is recom- mended that the brace angle be adjusted before hex nuts are fully tightened. Approvals -Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spac- ing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish -Plain Note -Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By-Order first by pipe size to be braced, followed by pipe size used for bracing, figure number and finish. Maximum Design Load 1" thru 4" pipe size -2015 lbs. 6" size -1265 lbs. Lateral Brace TOLco® brand bracing components are desgined to be compatible QMJ.Y with other TOLco® brand bracing components, resulting In a Listed seismic bracing assembly. DISCLAIMER -NIBCO does .MQI warrant against the failure of TOLco® brand bracing components, In the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLco® brand. NIBCO shall .MQI be liable under any circumstance for any direct or Indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY• 1375 SAMPSON AVE.• CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800. 786.5266 www.totco.com ■ ® TQLCO www.tolco.com . " NI Be□• Rev1s1on 3/28, 2003 Fig. 4A -Pipe Clamp for Sway Bracing Size Range -4" thru 8" pipe. For sizes smaller than 4" use TOLCO™ Fig. 4. Material -Carbon Steel Function -For bracing pipe against sway and seismic disturbance. Approvals -Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) 4" thru 8". Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). Installation Instructions -The Fig. 4A is the "braced pipe" attachment component of a longitudinal, lateral or riser brace assembly. It is intended to Component of State of California OSHPD Approved Seismic Restraints System / / / be combined with the "bracing pipe" and TOLCO transitional and structural , attachment component(s) to form a complete bracing assembly. NFPA 13 '-- and/or OSHPD guidelines should be followed. To Install -Place the Fig . 4A over the pipe to be braced. Attach TOLCO transitional fitting, either Fig. 980, 91 O or 909, to the clamp ears. Tighten bolts and nuts; torque requirement is a minimum of 50 ft. lbs. Transitional fitting attachment can pivot for adjustment to proper brace angle. Finish -Plain Note -Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By -Figure number, pipe size and finish fl c@us umo B A Fig. 4A -Longitudinal Brace TOLco® brand bracing components are desgined to be compatible QMLY with other TO Leo® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER -NIBCO does HQI warrant against the failure of TOLco® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLco® brand. NIBCO shall HQ! be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. Pipe Sizes 4 5 6 8 Dimensions • Weights Max. Horizontal A B C D Bolt Size Design Load 8½ 9/16 3% 31Yi6 1/2 2015 9¼ 9/16 3¼ 4% 1/2 2015 11½ 5/8 5 5¼ 1/2 2015 131/4 3/4 611/ia 6¼ 1/2 2015 OFFICE/MANUFACTURING FACILITY• 1375 SAMPSON AVL • CORONA CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Approx. wt./100 221 253 513 601 ■ ANGLE FEMALE x MALE COUBLE FEMALE FUNCTION: Used with a fire hose rack assembly or as a fire dept outlet connection. REGULARLY FURNISHED: Cast brass valve with red handwheel. Female NPT inlet x male hose thread outlet. 300 PSl/20.6 bars. Model 4060 . . . . . . . . . . . . . . . . . . . . . 1 ½" /3.B cm Size 4065 ..................... 2½"/6.4 cm Size SPECIFY: Thread OPTIONAL FINISHES: -8 Polished Brass -C Rough Chrome Plated -0 Polished Chrome Plated VARIATIONS: Extended stem up to 24"181 cm, SPECIFY: Length )('1.scm petcock SPECIFY: Location. iii; ,~ . CIQlld :,open, A-•e· c· ' .c D E , Iii, ; :1ri. • ti\. ' In. In. In. ·var A ill .. ,cm· .. . u,;, fffl, .rm YES YES 2¼ 3'/, 6'/, 7'1, 2'/, 2 5.7 8.9 16.5 19 6.4 5 YES YES 3'/, 5 9'/, 11'/, 3'/t 2'/• B.9 12.7 24. 1 29.2 8.9 6.9 FUNCTION: Used with a fire hose rack assembly. REGULARLY FURNISHED: Cast brass valve with red handwheel. Female NPT inlet and outlet. 300 PSl/20.6 bars. Model 4070 ..................... 1 ½" /3.8 cm Size 4075 ..................... 2½" /6.4 cm Size D Female X Male shown ADJUSTABLE PRESSURE RESTRICTING ANGLE VALVE FEMALE x MAI-E COUBLE FEMALE FUNCTION: Used with a fire hose rack assembly or as a fire dept outlet connection. Water pressure is controlled by adjustable flow • i:estrictlon. If full flow is required, the restriction may be overridden. REGULARLY FURNISHED: Cast brass valve with red handwheel with pressure restricting feature. Female NPT inlet x male hose thread outlet. 175 PSl/12 bars rated. Furnished with field setting chart. Model 4080 ..................... 1½"/3.BcmSize 4085 ..................... 2½''/6.4 cm Size SPECIFY: Thread OPTIONAL FINISHES: -B Polished Brass -C Rough Chrome Plated -D Polished Chrome Plated FUNCTION: Used with a fire hose rack assembly. Water pressure Is controlled by adjustable flow restriction. If full flow is required, the restriction may be overridden. REGULARLY FURNISHED: Cast brass valve with red handwheel with pressure restricting feature. Female NPT Inlet and outlet. 175 PSlI12 bars rated. Furnished with field setting chart. Model 4090 ..................... 1 ½" /3.8 cm Size 4095 ..................... 2½" 18.4 cm Size Page 4-8 Reliabl~ Bulletin 136 Rev.M Model F1FR Model F1 FR Recessed Quick Response Sprinklers ClJ s. m. s· -J. (,J 0) ::c ~ ---'--'---"'-"-=-"'-=--'---=-_;c_c_;:c.=..c==::........:c======::...=.-------------------~ Model F1 FR Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall -HSW 1 Deflector Model F1 FR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall -HSW 1 Deflector Listings & Approvals 1. Listed by Underwriters Laboratories, Inc. (UL) 2. Listed by Underwriters' Laboratories of Canada (ULC) 3. Certified by FM Approvals 4. Loss Prevention Council (LPC, UK) 5. NYC BS&A No. 587-75-SA 6. Meets MIL-S-901C and MIL-STD 167-1 7. Verband der Schadenversicherer (VdS, Germany) 8. NYC MEA 258-93-E UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNIV I Patents: US Patent No. 6,374,920 Applies to Model F1 FR Vertical Sidewall Sprinklers. Product Description Reliable Models F1 FR and F1 FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The Models F1 FR and F1 FR Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demoostrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR and F1 FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. The balance of parts are made of brass, oopper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid ex- Upright Vertical Sidewall Horizontal Sidewall HSW 1 Deflector / Pendent Conventional Recessed Pendent (Model FP Shown) pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 525 North MacOuesten Parkway, Mount Vernon, New York 10552 Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Sprinkler Type KFactor Sprinkler Approval Standard-Uplight (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position us Metric Height Organization Y,," (15nm) Standard Orifice with ½" NPT (RY.l Thread 5.6 80 2.2" (56rrml 1,2,3,4,5,6, 7 11/.." (20mm) Larae Orifice with 1/." NPT (R¾)Thread 8.0 115 2.3"(56rrm) 1,2,3,4, 7,8 1/,." (17rm,) Small Orifice with Y,,• NPT (RY,_) Thread 4.2 60 2.2'' (56rrm) 1,2,8 1/." (10mm) Small Orifice with Y," NPT (AX) Thread 2.8 40 2.2" (56rrml 1,2,8 10mm Orifice XL.H with R¾" Thread 4.2 60 56rrm 4,6.7 ConventionaJ....lnstaJI in Uorioht or Pendent Position 10mm Orifice XLH with R¾ Thread 4.2 60 56mm - 15mm Standard Orifice with Y,_" NPT (RY,_) Thread 5.6 80 56mm 4,6,7 20mm Laroo Orifice with ¾" f.JPT (R3/4)Toread 8.0 115 58mm 4.7 Upright Pendent Model F1 FR Quick Response Recessed Pendent Sprinkler I Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Thread K Factor Orifice Size us Metric Y," (15mm) Y,"NPT(R½) 5.6 80 '1/.." (20mm) ¾"NPT(R¾l 8.0 115 1/.," (11rm,) Y,_"NPT(R½) 4.2 60 ¾" (10mm) Y,"NPT(R½) 2.8 40 10mm R¾ 4.2 60 (l) Refer to escutcheon data table for approvals and dimensions. TURN COi.i.AR UNTl TIQtr ACMm SPRINl<!.CR WRCNCH BOSS~ ,- 1 l/4" HOt.C DIA. {'1.2mm} I 15/16" DO< {49.2-rnrFI] ( -._ ...-:i ---=- rACC or rtmNC 10 r,J C£1UNC OIAICNSION 1J6FGOI_£ S~rinkler eight Approva111 > Organ lzatlons 2.2" (56rrm) 1,2.3.4.5, 7 ,8 2.3" (56rrml 1,2,3,8 22"(56rrm) 1,2,8 2.2" (56rrm) 1,2,8 56rrm 4,7 2 :J/8" DIA {66.7mm) HOLC IN CC/LINC 2 :i/16" DIA. {!j[j.Jmm] r~ ~~~ I I T-----'-----\ I ,, \ I ~ -~ L CDUNC ADJUSTM[NT r,J Sprinkler Identification Number (SIN) ssu SSP R3625 R3615 R3622 R3612 R3623 R3613 R3621 R3611 R3624 R3614 R3674 R3675 R3672 Conventional Sprinkler Identification Number (SIN) R3615 R3612 R3613 R3611 R3614 I" X 1/2" REDUCER FACE OF FfTTINC TO FACC OF CEIL/NC OtM[NSION (t) t--r-r.r?tr.771 1 (I) Rff£R TO Fl 4 F2 CSCUTCHCON ll4TA TABU FOR N'PROIN.S NJD DIM[NSIONS. (1) RCFCR TO FP ESCUTCHEON £1.<TA TABLE FOR APPROVALS ANO DIJJENSIONS. 2. Model F1 FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data· Nominal Thread K Factor Approval Orifice Size us Metric Sprinkler Height Organizations ½H ½" NPT (R½) 5.6 80 2.2" (56mm) 1,2,3,6,8 15mm ½" NPT (R½) 5.6 80 2.2" (56mm) 4 (1) <1> LPC Approval is for Pendent position only. Orientation Deflector to Celling Dimension (Min. -Max.) Uorioht 4" -12" (102mm -305mm) Pendent 6" -12" (152mm -305mm) Vertical Sidewall I US Patent No. 6,374,920 Model F1 FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprin kler Wrench Installation Data: K Factor Nominal Thread Orifice Size us Metric ½" (15mm) ½" NPT(R½) 5.6 80 Strinkler ength 2.63" (67mm) NOTE: UL, ULC and MEA Listing permits use with F1 or F2 recessed escutcheon. Approval ~nlzatlons and Type Approval Light Hazard Ordinary Hazard 1,2,3,5,8 1,2,5,8 Sprinkler Identification Number (SIN) R3685 Sprinkler Identification Number (SIN) R3635 ~/ffe/1/1%1 ( 1) F'ACE o; F/TTIN~ ro ---1-...; WALL OIM[NSIO/v / Horizontal Sidewall ; 1/• • "OLE 0;;1. {57.2mmj t-----t I 1/4 .. MIN. [J1.8mm} 2 27/J2" DIA. [72.2mm} ! ~AWU!>'IMLN/ (I) (I} REF::R ro [SCU~HCEON DATA TABLE FOR APPROVALS AND OIAl[NSIONS. 3. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Medel F1 FR Recessed Quick Response Sprinklers are to be installed as st-own. The Medel F1 cr F2 Escutchems illus- trated are the only recessed escutcheons to be used with the Medel F1 FR Sprinklers. The use of any other recessed escutch- eon will void all approvals and negate all warranties. vVhen installing Medel F1 FR Sprinklers, use the Medel D Sprin- kler Wrench. 'Mlen installing Model F1 FR Recessed Pendent or Side.val! Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- rmval of the protectors before this time may leave the bulb vul- nerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperature Ratings Sprinkler Max. Ambient Classlflcatlon T-, re Temp. ·c •f Ordinary 57 13.5 100°F (38°C) Ordinary 68 15.5 100°F (38°C) Intermediate 79 175 150°F (66°C) lnterm~diate 93 200 150°F (66°C) High<1 141 286 225"F(107°C) <1> Not available for recessed sprinklers. Escutcheon Data EsQtileon Appr'0Wls "A" Model A4Jslrnent Dmenslon 1Yz" F1 1,2.4,8 Max Recess (38.1mm) Min Recess ¾" /19.1mm\ 1Yz" F2 1,2,3,4,5,7,8 Max Recess (38.1mm) Min Recess 'X•" /24mml y," FP 1,2 Max Recessed • 111mml P\Jsh.a\l •r,. Thread-off 1,2 Min Recessed (24mm) No Dimensional Figure for FP Maintenance Bulb Color Orange Red YelloN Green Blue Facec:IFIDlg loCelngor WeJ Dinension ¾s" -1Xs" (5nvn-24mn) 3/,t-1Y,6,. (5rrm-17rrrn) 1Y,"(38.1mrn) 1"(25.4mm) The Models F1 FR and F1 FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1 ) Recessed Pendent Recessed Horizontal Sidewall HSW1 Finishes <1> <2> Standard Anlshes Sorinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated 13> White Polyester Coated White Painted l3> Soecial ADDlicatlon Anlshes Sorinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome 11) Other finishes and colors are available on special order. Consult the factory for details. (2) FM Approvals is limited to bronze and brass, chrome or black plated finishes only. (3) FP Push-on/Thread-off escutcheon Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) Note: When Model F1 FR Recessed sprinklers· are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association. Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa-ble sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliabl_.. The Reliable Automatic Sprinkler Co., Inc. (800)431-1588 Sales Offices (800)848-6051 Sales Fax (914)668--3470 Corporate Offices ,:;;,.. Recycled ~ Paper Revision lines indicate updated or new data www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 7J05 P/N9999970027