HomeMy WebLinkAbout1098 MAGNOLIA AVE; ; CBRA2023-0090; PermitBuilding Permit Finaled
(city of
Carlsbad
Residential Associated Permit
Print Date: 09/16/2024
Job Address: 1098 MAGNOLIA AVE, CARLSBAD, CA 92008-2538
Permit No:
Status:
CBRA2023-0090
Closed -Finaled
Permit Type: BLDG-Associated Permit Residential Work Class: Single Family Detached
Parcel#: 2051912900 Track#:
Valuation: $575,943.13 Lot#:
Occupancy Group:
#of Dwelling Units: 1
Project#:
Plan#:
Bedrooms: Construction Type:
Bathrooms:
Occupant Load:
Orig. Plan Check #: PC2022-0001
Plan Check #:
Code Edition:
Sprinkled:
Project Title:
-Description: NEW (3,538 SF) DWELLING, (636 SF) ROOF DECK, (312 SF) PATIO, (599 SF) GARAGE
Applicant: Property Owner:
KIRK MOELLER ARCHITECTS INC
KIRK MOELLER
DOKHANCHY-PHANEUF FAMILY TRUST
12-08-05
2888 LOKER AVE E, # STE 220
CARLSBAD, CA 92010-6685
(760) 814-8128
FEE
ATTACHED ACCESSORY & UTILITY USES
DETACHED ACCESSORY & UTILITY USES
PUBLIC FACILITIES FEES -outside CFO
1098 MAGNOLIA AVE
CARLSBAD, CA 92008-2538
SB1473 -GREEN BUILDING STATE STANDARDS FEE
SDCWA SYSTEM CAPACITY l" Displacement
SEWER CONNECTION FEE (General Capacity all areas)
SFD & DUPLEXES
STRONG MOTION -RESIDENTIAL (SM IP)
SWPPP INSPECTION TIER 1 -Medium BLDG
SWPPP PLAN REVIEW TIER 1 -Medium
TRAFFIC IMPACT Residential Single Fam. Outside CFO
WATER CONNECTION 1" Ultrasonic (P)
WATER METER FEE 1" Potable-Ultrasonic
WATER TREATMENT CAPACITY 1" Displacement
Total Fees: $40,919.81 Total Payments To Date:
Building Division
$40,919.81
Applied: 07/10/2023
Issued: 07/17/2023
Finaled Close Out: 09/10/2024
Final Inspection: 08/15/2024
INSPECTOR: de Roggenbuke, Dirk
Renfro, Chris
Balance Due:
AMOUNT
$958.33
$958.33
$20,158.01
$24.00
$5,700.00
$1,074.00
$2,207.64
$0.50
$292.00
$69.00
$4,050.00
$4,870.00
$399.00
$159.00
$0.00
Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
Building Permit Inspection History Finaled
{city of
Carlsbad
PERMIT INSPECTION HISTORY for (CBRA2023-0090)
Permit Type: BLDG-Associated Permit Residenti, Application Date: 07/10/2023 Owner: TRUST DOKHANCHY-PHANEUF
FAMILY TRUST 12-08-05
Work Class: Single Family Detached Issue Date: 07/17/2023 Subdivision: ALLES AVOCADO ACRES RESUB
Status: Closed -Finaled Expiration Date: 11/12/2024
IVR Number: 50517
OFPOR
Address: 1og@,MAGNOLIA AVE
CARLSBAD, CA 92008-2538
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date
07/19/2023 07/19/2023 BLDG-SW-Pre-Con
Checklist Item
217860-2023
COMMENTS
Status
Passed Chris Renfro Complete
Passed
Yes BLDG-Building Deficiency
NOTES Created By
Angie Teanio
TEXT Created Date
925-705-6173 Mehrdad / 760-519-1004 Mike, 07/18/2023
08/03/2023 08/03/2023 BLDG-11
Foundation/Ftg/Piers
(Rebar)
Checklist Item
superintendent
219527-2023 Partial Pass Chris Renfro
COMMENTS
BLDG-Building Deficiency
BLDG-12 Steel/Bond
Beam
Checklist Item
219528-2023
COMMENTS
Passed Chris Renfro
BLDG-Building Deficiency
08/25/2023 08/25/2023 BLDG-14
Frame/Steel/Bolting/We
lding (Decks)
Checklist Item
222001-2023 Partial Pass Dirk de Roggenbuke
COMMENTS
BLDG-Building Deficiency 8/25/23 sub floor framing ok
09/05/2023 09/05/2023 BLDG-21
Underground/Underflo
or Plumbing
Checklist Item
222761-2023 Partial Pass Chris Renfro
COMMENTS
BLDG-Building Deficiency Underfloor plumbing in raised foundation,
subfloor. OK to insulate and sheet.
09/11/2023 09/11/2023 BLDG-14
Frame/Steel/Bolting/We
lding (Decks)
Checklist Item
223477-2023 Passed Dirk de Roggenbuke
COMMENTS
BLDG-Building Deficiency 8/25/23 sub floor framing ok
9/11 /23 sub floor sheathing ok
09/29/2023 09/29/2023 BLDG-14
Frame/Steel/Bolting/We
lding (Decks)
Tuesday, September 10, 2024
225450-2023 Partial Pass Chris Renfro
Reinspection Incomplete
Passed
Yes
Complete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Complete
Passed
Yes
Reinspection Incomplete
Page 1 of 3
PERMIT INSPECTION HISTORY for (CBRA2023-0090)
Permit Type: BLDG-Associated Permit Residenti, Application Date: 07/10/2023 Owner: TRUST DOKHANCHY-PHANEUF
FAMILY TRUST 12-08-05
Work Class: Single Family Detached Issue Date: 07/17/2023 Subdivision: ALLES AVOCADO ACRES RESUB
OFPOR
Status: Closed -Finaled Expiration Date: 11/12/2024 Address: 10~ MAGNOLIA AVE
IVR Number: 50517 CARLSBAD, CA 92008-2538
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency 2nd story deck nailing Yes
11/02/2023 11/02/2023 BLDG-15 Roof/ReRoof 229256-2023 Cancelled Chris Renfro Reinspection Incomplete
(Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
11/07/2023 11/07/2023 BLDG-15 Roof/ReRoof 229618-2023 Passed Chris Renfro Complete
(Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/11/2023 12/11/2023 BLDG-13 Shear 232963-2023 Passed Chris Renfro Complete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
02/05/2024 02/05/2024 BLDG-84 Rough 238681-2024 Partial Pass Chris Renfro Re Inspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready. Need exterior wrapped, and No
watertight.
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
02/20/2024 02/20/2024 BLDG-84 Rough 239808-2024 Passed Chris Renfro Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
03/11/2024 03/11/2024 BLDG-82 Drywall, 241280-2024 Passed Chris Renfro Complete
Exterior Lath, Gas Test,
Hot Mop
Tuesday, September 10, 2024 Page 2 of 3
PERMIT INSPECTION HISTORY for (CBRA2023-0090)
Permit Type: BLDG-Associated Permit Residenti: Application Date: 07/10/2023 Owner: TRUST DOKHANCHY-PHANEUF
FAMILY TRUST 12-08-05
Work Class: Single Family Detached Issue Date: 07/17/2023 Subdivision: ALLES AVOCADO ACRES RESUB
Status: Closed -Finaled Expiration Date: 11/12/2024
IVR Number: 50517
OF POR
Address: 1098MAGNOLIA AVE
CARLSBAD, CA 92008-2538
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection Primary Inspector Reinspection Inspection
Checklist Item
BLDG-Building Deficiency
BLDG-17 Interior Lath-Drywall
BLDG-18 Exterior Lath and
Drywall
BLDG-23 Gas-Test-Repairs
Status
COMMENTS
05/16/2024 05/16/2024 BLDG-33 Service 248778-2024 Passed Chris Renfro
Change/Upgrade
Checklist Item COMMENTS
BLDG-Building Deficiency
07/31/2024 07/31/2024 BLDG-Final Inspection 256415-2024 Partial Pass Chris Renfro
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
COMMENTS
Pre-final walk. Need to address stair
handrail. Need final paperwork.
08/08/2024 08/08/2024 BLDG-Final Inspection 257299-2024 Failed Chris Renfro
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
COMMENTS
Not ready: Pre-final walk. Need to address
stair handrail. Need final paperwork.
08/15/2024 08/15/2024 BLDG-Final Inspection 257940-2024 Passed Chris Renfro
Tuesday, September 10, 2024
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
COMMENTS
Passed
Yes
Yes
Yes
Yes
Complete
Passed
Yes
Reinspection Incomplete
Passed
No
Yes
Yes
Yes
Yes
Reinspection Incomplete
Passed
No
Yes
Yes
Yes
Yes
Complete
Passed
Yes
Yes
Yes
Yes
Yes
Page 3 of 3
-
October 29, 2021
Mehrdad Dokhanchy
1098 Magnolia A venue
Carlsbad, California 92008
SUBJECT: File No. 1106F6-21
SITE INSPECTION
Dear Mr. Dokhanchy:
SCOPE
Proposed Residential Building Site
Next to 1098 Magnolia Avenue
City of Carlsbad
P.O. Box 1195
Lakeside, California
92040
(619) 443-0060
c,rv j
In accordance with your request, a Site Inspection has been performed at the subject site. The
purpose of this investigation was to examine existing site conditions and provide engineering
recommendations for the proposed two story single family residence.
If project details vary significantly from those described, Soil Testers should be notified
prior to final submittal for revision and possible revision of the recommendations
presented herein. It is our understanding that the septic system layout and grading plan
have not been finalized . We should be provided this information for review for possible
modifications to this report and recommendations.
This report is issued with the understanding that it is the responsibility of the owner or the
owner's representative to ensure that the information and recommendations contained herein
are brought to the attention of the architect and engineer for the project and incorporated into
the plans, and the necessary steps are taken to see that the contractor and subcontractors carry
out such recommendations in the field.
FIELD INSPECTION
In order to accomplish this purpose, a representative of this firm visited the site, reviewed the
topography and site conditions and visually and textually classified the surface and near
surface soils. Representative samples of the on-site soils were obtained from 2 test
1
Mehrdad Dokhanchy File No. 1106F6-21 October 29, 2021
explorations approximately 4 feet m depth and tested for density, shear strength and
expansive characteristics.
SITE CONDITIONS
The subject site is located on the northerly side of Magnolia A venue. The site is a relatively
level vacant lot with a wood fence along the north and west property lines. Neighbo,ing
properties are occupied by single family residential structures. Fill materials were not
encountered, and loose native soils were encountered to a depth of approximately 3 to 4 feet
during the course of this inspection.
SOIL CONDITIONS
Soils encountered in the test explorations were native soils consisting of loose to firm, brown,
moist, fine, silty sands to the bottom of the explorations approximately 4 feet.
The soils we encountered were not considered to be detrimentally expansive with respect to
change in volume with change in moisture content.
CONCLUSIONS AND RECOMMENDATIONS
l. A representative sample of the foundation soil was remolded to 90% of maximum
dry density. Based on the following test results, a safe allowable bearing value of
at least 2000 pounds per square foot for 12 inch deep footings may be used in
designing the foundations and slab for the proposed structures. This value may be
increased by one third for wind and/or seismic loading. This value may be
increased by 20 percent for each additional foot of depth and or width to a
maximum of 3 times the designated value.
Maximum Dry Density
Optimum Moisture
Angle of internal friction
Cohesion
Unit weight
Expansion Index
131.9 pcf
8.6%
30°
164 psf
120.2 pcf
21
2. Lateral resistance to horizontal movement may be provided by the soil passive
pressure and friction of concrete to soil. An allowable passive pressure of 250
pounds per square foot per foot of depth may be used. A coefficient of friction of
0.35 is recommended. The soils passive pressure may be increased by 1/3 for wind
and seismic loading.
2
Mehrdad Dokhanchy File No. l 106F6-2 l October 29, 2021
3. The seismic parameters for the site coordinates 33.1560767°N, 117.3360538 °W
for assumed Site Class D are as follows:
• Ss = 1.058 g
• Si = 0.383 g
Sms = 1.269 g
Sm1 = nu11
Sds = 0.846 g
Sd1 = null
4. The loose, compressible native soils we encountered should not be utilized to support
the proposed new structure. They should be recompacted to at least 90 percent of
ma,'{imum dry density in accordance with the Grading Specifications in this report in
order to provide adequate support for the proposed new structures. Anticipated depth
of recompaction is 3 to 4 feet. The recompaction should extend at least five feet
outside the proposed building footprints. Organic materials and roots must be
removed from the soils before replacement. A representative of Soil Testers should
be onsite to approve the removal of the loose soils prior to placement of fill soils.
5. Conventional spread footings founded a minimum of 12 inches below lowest adjacent
grade and having a width determined by the allowable soil bearing value as detailed
above are recommended for foundation support. Footing widths should be at least 12
inches for continuous footings and 24 inches for square footings due to practical
considerations as well as Building Code requirements. These recommendations are
based entirely upon the soil types and do not take into consideration the requirements
of the proposed structure.
6. Reinforcing in footings should consist of at least one #4 steel bar placed continuously
in the top and bottom of continuous footings regardless of structural requirements.
Reinforcing for isolated footings is dictated by the structural requirements. These
recommendations are based upon on the soil type encountered and do not take into
consideration the proposed bearing load.
7. Concrete Slab-On-Grade, SOG, should be designed by the project's structural
engineer based on anticipated loading conditions. We recommend that
conventional reinforced concrete SOG for this project be founded on 4 inches of
Class II Virgin Aggregate Base (with approximately 2% +/-over optimum moisture
content and 90% compaction, relative to the lab maximum dry density, ASTM D
1557), overlying a 12 inch thick zone of adequately placed and compacted
structural fill.
We recommend that a moisture barrier be provided by a membrane, visqueen 10
mils in minimum thickness or equivalent, be placed at top of well compacted Class
3
_ Mehrdad Dokhanchy File No. l 106F6-21 October 29, 2021
II Aggregate Base, then covered with 2 inches of moist clean sand having a
minimum sand equivalent of 30 when tested in accordance with the American
Society of Testing and Materials test method 'ASTM DI 555.
Floor slabs, as a minimum, should be 5 inches thick with #4 reinforcing steel at 16"
on-center each way. Reinforcement should be placed at mid-height of the slab. The
final slab thickness and reinforcement should be determined by the structural
design engineer. Control joints should be provided in accordance with the
recommendations of the structural design engineer.
SITE EROSION CONTROL
During the construction, surface water should be controlled via berms, gravel bags and/or
sandbags, silt fence, straw wattles, siltation basins, while maintaining positive surface
grades or other methods to avoid damage to the finish work or adjoining properties. All
site entrances and exits must have coarse gravel or steel shaker plates to minimize offsite
sediment tracking. Best management Practices (BMP's) must be used to protect storm
drains and minimize pollution. The contractor should take measures to prevent erosion of
graded areas until such time as permanent drainage and erosion control measures have
been installed. After completion of grading, all excavated surfaces should exhibit
positive drainage and eliminate areas where water might pond.
SITE AND SURF ACE DRAINAGE
Drainage at the site should be directed away from foundations, collected and tight lined to
appropriate discharge points. Consideration may be given to collecting roof drainage by
eave gutters and directing it away from foundations via non-erosive devices. Water, either
natural or from irrigation, should not be permitted to pond, saturate the surface soils or
flow towards the foundation. Landscaping requiring a heavy irrigation schedule should not
be planted adjacent to foundations or paved areas. The type of drainage issues found within
the project and materials specified and used should be determined by the Engineer of
Record.
GROUNDWATER AND SURFACE WATERS
There was no indication of a near-surface groundwater table within our exploratory trench
or perched groundwater. Although groundwater is not expected to be a significant
constraint to the proposed development, our experience indicates that near-surface
groundwater conditions can develop in areas where no such groundwater conditions
previously existed, especially in areas where a substantial increase in surface water
infiltration results from landscape irrigation or unusually heavy precipitation. It is
4
Mehrdad Dokhanchy File No. 1106F6-21 October 29, 2021
anticipated that site development will include appropriate drainage provisions for control
and discharge of surface water runoff. The type of drainage issues found within the project
and materials specified and used should be determined by the Civil Engineer. The type of
plants and soil specified along with proper irrigation used should be determined by the
Landscape Architect.
The following grading specifications should be utilized if grading is proposed.
RECOMMENDED GRADING SPECIFICATIONS
For
Proposed Residential Building Site
Next to 1098 Magnolia Avenue
City of Carlsbad
GENERAL: Soil Testers and 'Engineer' are synonymous hereinafter and shall be employed
to inspect and test earthwork in accordance with these specifications, the accepted plans, and
the requirements of any jurisdictive governmental agencies. They are to be allowed adequate
access so that the inspections and tests may be performed. The Engineer shall be apprised of
schedules and any unforeseen soil conditions.
Substandard conditions or workmanship, inadequate compaction, adverse weather, or
deviation from the lines and grades shown on the plans, etc., shall be cause for the engineer
to either stop construction until the conditions are corrected or recommend rejection of the
work. Refusal to comply with these specifications or the recommendations and/or
interpretations of the engineer will be cause for the engineer and/or his representative to
immediately terminate his services.
A pre-construction meeting or conference with the developer, contractor, civil engineer,
soil engineer, and the agency inspector in attendance should be held at the site prior to the
beginning of the grading operations. Special soil handling requirements can be discussed at
that time.
Grading of the site should commence with the removal of all vegetation and existing
improvements from the area to be graded. Deleterious material and debris such as broken
asphalt and concrete, underground pipe materials, wires, trash, etc. if encountered, should
be exported from the site and should not be mixed with the fill soils.
Abandoned foundations and buried septic tanks or cisterns (if encountered) should be
removed and the subsequent depressions and /or trenches should be filled with properly
compacted materials as part of the remedial grading.
5
Mehrdad Dokhanchy File No. 11 06F6-2 l October 29, 2021
All fill and backfill soils should be placed in horizontal loose layers approximately 8 inches
thick, moisture conditioned to a water content of one to three percent above optimum
moisture content, and compacted to at least 90 percent relative compaction, as determined
by ASTM Test Method D 1557-00.
The excavation bottom should then be scarified to a depth of approximately 6 to 8
inches, moisture-conditioned to 1 to 3 percent above optimum moisture content, and re-
compacted to a minimum relative compaction of 90 percent in accordance with ASTM
D 1557-00. Excavated sandy or clayey soils should then be uniformly moisture
conditioned at above optimum moisture content, placed in 8-inch-thick loose layers and
compacted to a relative compaction of at least 90 percent.
Import fill soil, if required, should consist of granular materials with low expansion
potential (EI less than 50 or stated by the soil engineer) and should be compacted as
indicated herein. Soil Testers should be notified of the import source and should
perform laboratory testing of the soil prior to its arrival at the site to determine its
suitability as fiH material.
Deviations from the recommendations of the Soil Report, from the plans, or from these
Specifications must be approved in writing by the owner and the contractor and
endorsed by the engineer.
SOIL TEST METHODS:
Maximum Density & Opt Moisture
Density of Soil In-Place
--ASTM Dl557-70
--ASTM Dl556, D2922 and D3017
Soil Expansion
Shear Strength
Gradation & Grain Size
Capillary Moisture Tension
Organic Content
--UBC STANDARD 29-2
--ASTM D3080-72
--ASTM Dl 140-71
--ASTM D2325-68
--% Weight loss after heating for 24 hours
at 300° F and after deducting soil moisture.
LIMITING SOIL CONDITIONS:
Minimum Compaction
Expansive Soils
Insufficient fines
Oversized Particles
90% for 'disturbed' soils. (Existing fill,
newly placed fill, plowed ground, etc.)
84% for natural, undisturbed soils.
95% for pavement subgrade within 2' of
finish grade and pavement base course.
Expansion index exceeding 20
Less than 40% passing the #4 sieve.
Rocks over 10" in diameter.
6
Mehrdad Dokhanchy File No. 1106F6-21 October 29, 2021
PREPARATION OF AREAS TO RECEIVE FILL:
Brush, trash, debris and detrimental soils shall be cleared from the areas to receive fill.
Detrimental soils shall be removed to firm competent soil. Slopes exceeding 20% should be
stepped uphill with benches l 0' or greater in width. Scarify area to receive fill to 6" depth and
compact.
FILL MATERIAL shall not contain insufficient fines, oversized particles, or excessive
organics. On-site disposition of oversized rock or expansive soils is to be at the written
direction of the Engineer. Select fill shall be as specified by the engineer. All fills shall be
compacted and tested.
SUBDRAINS shall be installed if required by and as directed by and detailed by the engineer
and shall be left operable and unobstructed. They shall consist of 3" plastic perforated pipe set
in a minimum cover of 4" of filter rock in a 'vee' ditch to intercept and drain free ground from
the mass fills. Perforated pipe shall be schedule 40, Poly-Vinyl-Chloride or Acrylonitrile
Butadienne Styrene plastic. Rock filter material shall conform to the following gradation:
Sieve size:
%Passing:
3/4"
90-100
#4
25-50
#30
5-20
#200
0-7
Subdrains shall be set at a minimum gradient of 0.2% to drain by gravity. Drains found
inoperable shall be excavated and replaced.
CAPPING EXPANSIVE SOILS: If capping expansive soils with non-expansive soil to
mitigate the expansive potential is used, the cap should be compacted, non-expansive, select
soil placed for a minimum thickness 3' over the expansive soil and for a minimum distance of
8' beyond the exterior perimeter of the structure. Special precautions should be taken to
ensure that the non-expansive soil remains uncontaminated and the minimum thickness and
dimensions around the structure are maintained. The expansive soils underlying the cap of
non-expansive cap should be pre-saturated to a depth of 3' to obtain a degree saturation
exceeding 90% before any construction supported by the compacted cap.
The non-expansive soil comprising the cap should conform to the following:
Minimwn Compaction
Maximum Expansion Index
Minimum Angle oflnternal Friction
Cohesion Intercept
7
90%
30
33 Deg
100 psf
Mehrdad Dokhanchy File No. 1106f 6-2 l October 29, 2021
UNFORESEEN CONDITIONS: Soil Testers assume no responsibility for conditions,
which differ from those, described in the applicable current reports and documents for this
property. Upon termination of the engineer's services for any reason, his fees up to the time of
termination become due and payable. If it is necessary for the engineer to issue an
unfavorable report concerning the work that he has been hired to test and inspect, the engineer
shall not be held liable for any damages that might result from his 'unfavorable report'.
If we can be of any further assistance, please do not hesitate to contact our office. This
opportunity to be of service is sincerely appreciated.
Respectfully submitted,
CCC/mlj
8