Loading...
HomeMy WebLinkAbout1276 PINE AVE; ; PC2023-0006; PermitBuilding Permit Finaled Plan Check Permit Print Date: 08/07/2024 Job Address: Permit Type: Parcel #: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: 1276 PINE AVE, CARLSBAD, CA 92008-1938 BLDG-Plan Check Work Class: 2050205600 Track#: $0.00 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Residential Permit No: Status: ( City of Carlsbad PC2023-0006 Closed -Finaled Applied: 02/14/2023 Issued: 07/05/2023 Finaled Close Out: 05/31/2024 Final Inspection: INSPECTOR: Description: 1274 PINE (MAIN SFD) AND 1276 PINE (ADU): ENLARGE ADU BY (438 SF) AND REDUCE EXISTING SFD FOOTPRINT (438 SF) CREATING 2 NEW BEDROOMS IN SFD MAIN Applicant: ADAM FISCH BACH 1640 OCEANSIDE BLVD OCEANSIDE, CA 92054-5427 FEE BUILDING PLAN CHECK FEE (manual) REMODEL-RESIDENTIAL -OTHER Total Fees: $1,084.25 Building Division Total Payments To Date: $1,084.25 Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov AMOUNT $427.13 $657.12 $0.00 Page 1 of 1 l { City of Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION 8-1 Plan Check 'n:!Z.023 -DOap Est. Value Jt .,o, '1>•£• tS, PC Deposit JI ~a,7. 13 Date 3,~/~ ,...20~~ Job Address 1276 Pine Ave Carlsbad CA 92008 Unit: _____ APN: 205-02-04-00 CT /Project #: __________________ Lot #:, ____ Year Built: _________ _ BRIEF DESCRIPTION OF WORK: Enlarge ADU by 438 SQ FT and reduce main dwelling by 438 SQ. FT. This results in the addition of 2 new bedrooms within the existing footprint of the single family home. 0 New SF: living SF,. ____ Deck SF,. ___ Patio SF,, ____ Garage SF __ _ Is this to create an Accessory Dwelling Unit? O Y O N New Fireplace? O YO N, if yes how many? ___ _ EJ Remodel:_8_7_6 ___ SF of affected area Is the area a conversion or change of use? 0 Y C N □ Pool/Spa: ___ ___;SF Additional Gas or Electrical Features? ____________ _ OSolar: ___ KW, ___ Modules, Mounted:ORoof OGround, Tilt: 0Y0 N, RMA: OY ON, Battery:OYC N, Panel Upgrade: CY ON Electric Meter number: ___________ _ Other: APPLICANT (PRIMARY CONTACT) Name: Adam Fischbach Address: 1640 Oceanside Blvd City: Oceanside State: CA Zip: 92054 Phone: 760-580-1776 Email: development@beachfrontonly.com PROPERTY OWNER Name: 1284 Pine Avenue Partners, LLC Address: 1640 Oceanside Blvd City: Oceanside Phone: 760-580-1776 State: CA Zip:_9_2_05_4 __ _ Email : development@beachfrontonly.com DESIGN PROFESSIONAL Name: Paul Longton Address: 2909 Mesa Dr CONTRACTOR OF RECORD Business Name: Owner / Builder Address:. _________________ _ City: Oceanside State: CA Zip: 92054 Phone: 760-722-4904 Email: development@beachfrontonly.com Architect State License: C18757 ------------ City:, _______ State:. ___ Zip:. ______ _ Phone: __________________ _ Email:, __________________ _ CSLB License #: _______ Class: ______ _ Carlsbad Business License# (Required):. _______ _ APPLICANT CERT/FICA TION: I certify that I have read the application and state that the above information is correct and that the information of the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. NAME (PRINT): Adam Fischbach SIGN 4 b------DATE 02/14/2023 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 : ~r ~mail: Building@carlsbadca.gov REV. 04122 THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _ A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE. (OPTION A): LICENSED CONTRACTOR DECLARATION: lherebyaffirmunderpenaltyofperjurythatlamlicensedunderprovisionsofChapter9(commencingwithSection7000)ofDivision3 of the Business and Professions Code, and my license is inf ul/ force and effect. I also affirm under penalty of per jury one of the following declarations {CHOOSE ONE): D I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. Policy No .. ___________________________________________ _ -OR- □I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name:------------------------• Policy No. _____________________________ Expiration Date:-----------------• -OR- D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: _______________________ lender'sAddress: ______________________ _ CONTRACTOR CERT/FICA TION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All improvements existing on the property were completed in accordance with all regulations in e>Cistence at the time of their construction, unless otherwise noted. NAME (PRINT): __________ SIGNATURE: __________ OATE: ______ _ Note: If the person signing above is an authorized agent for the contractor rovide a letter of authorization on contractor letterhead. (OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). -OR- M I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The igntractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). -OR- D1 am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: AND, D FORM B-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner. By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed In its entirety by licensed contractors./ understand that a copy of the applicable low, Section 7044 of the Business and Professions Code, is available upon request when this application is submitted or at the following Web site: http: I /www.leginfo.ca.gov/ calaw. html. OWNER CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All i::::n:s::::~;:the ;~:~e;~:;~::~a~cordance with all regul:i;:: ~xist~of their construction, unless 0 ::::~ot~2_ 14_2023 Note: If the erson si nln above is an authorized a ent for the ro ert owner include form B si ned b 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov 2 REV. 04/22 '. ( City of Carlsbad OWNER-BUILDER ACKNOWLEDGEMENT FORM 8-61 Development Services Building Division 1635 Faraday Avenue 442-339-2719 www.carlsbadca.gov I. II. Ill. IV. V. OWNER-BUILDER ACKNOWLEDGMENT FORM Pursuant to State of California Health and Safety Code Section 19825-19829 To: Property Owner An application for construction permit(s) has been submitted in your name listing you as the owner-builder of the property located at: SiteAddress 12J(a r1·rJJL Av-e. W(\~0vid (;,,A . Cf2D05? Th e City of Carlsbad ("City") is providing you with this Owner-Builder Acknowledgment and Verification form to inform you of the responsibilities and the possible risks associated with typical construction activities issued in your name as the Owner-Builder. The City will not issue a construction permit until you have read and initialed your understanding of each provision in the Property Owner Acknowledgment section below and sign the form. An agent of the owner cannot execute this notice unless you, the property owner, complete the Owner's Authorized Agent form and it is accepted by the City of Carlsbad. INSTRUCTIONS: Please read and initial each statement below to acknowledge your understanding and verification of this information by signature at the bottom of the form. These are very important construction related acknowledgments designed to inform the property owner of his/her obligations related to the requested permit activities. jjJrl understand a frequent practice of unlicensed contractors is to have the property owner obtain an "Owner• ~er" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed contractor and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner-Bu ilder and am aware of the limits of my insurance coverage for injuries to workers on my property . . ~ understand building permits are not required to be signed by property owners unless they are responsible ~yonstruction and are not hiring a licensed contractor to assume this responsibility. tlf[._1 understand as an "Owner-Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own. /.,1 ~nderstand contractors are required by law to be licensed and bonded in California and to list their license ~~;s on permits and contracts. J /4derstand if I employ or otherwise engage any persons, other than California licensed contractors, and ~tal value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. REV. 05/22 J • Owner-Builder Acknowledgement Continued VI. ~nderstand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk . .#nderstand under California Contractors' State License Law, an Owner-Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of t~e wor is performed under contract with a licensed general building contractor. VII. VIII. I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable f r any financial or personal injuries sustained by any subsequent owner(s) which result from any latent construction defects in the workmanship or materials. IX. V,understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800-321-CSLB (2752) or www.cslb.ca.gov for more information about lice sed contractors. X. XI. XII. am aware of and consent to an Owner-Builder building permit applied for in my name, and understand at I am the party legally and financially responsible for proposed construction activity at the following address: I 2-?lo 1?:t11!< Ar-, ~,,w CA qzoo e ~ree that, as the party legal!: and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner-Builders as well as employers. ~ to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractor's State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner- Builder and wish to hire contractors, you will be responsible for verifying whether or not those contractors are properly licensed and the status of their workers' compensation coverage. Before a building permit can be issued, this form must be completed, signed by the property owner and returned to the City of Carlsbad Building Division. I declare under penalty of perjury that I have read and understand of/ of the information provided an this form and that my responses, including my authority to sign this form, is true and correct. I am aware that I have the option to consult with legal counsel prior to signing this form, and I have either (1) consulted with legal counsel prior ta signing this form or (2) hove waived this right In signing this form without the advice of legal counsel. Property Owner Name (PRINT) ?fri/zJ Date 3 REV. OS/22 True North COMPLIANCE SERV ICES June 14, 2023 City of Carlsbad Community Development Department -Building Division 1635 Faraday Ave. City of Carlsbad -FINAL REVIEW City Permit No: PC2023-0006 True North No.: 23-018-123 Carlsbad, CA 92008 Plan Review: ADU/Remodel Address: 1276 Pine Ave Applicant Name: Adam Fischbach Applicant Email: development@beachfrontonly.com OCCUPANCY AND BUILDING SUMMARY: Occupancy Groups: R-3 Occupant Load: I 0 Type of Construction: V-B Sprinklers: Yes Stories: 2 Area of Work (sq. ft.): As Shown, existing sq. ft. The plans have been reviewed for coordination with the permit application. Valuation: Confirmed Scope of Work: Confirmed Floor Area: Confirmed Attn: Building & Safety Department, True North Compliance Services, Inc. has completed the final review of the following documents for the project referenced above on behalf of the City of Carlsbad: I. Drawings: One (I) copy dated January 5, 2023, by Swanson & Associates. 2. Structural Calculations: One (1) copy dated January 5, 2023, by Swanson & Assoc. Engineering. The 2022 California Building, Mechanical, Plumbing, and Electrical Codes (i.e., 2021 IBC, UMC, UPC, and 2020 NEC, as amended by the State of California), 2022 California Green Building Standards Code, 2022 California Existing Building Code, and 2022 California Energy Code, as applicable, were used as the basis of our review. Please note that our review bas been completed and we have no further comments. We have enclosed the above noted documents bearing our review stamps for your use. Please call if you have any questions or ifwe can be of further assistance. Sincerely, True North Compliance Services Review By: Bryan Montes -Plans Examiner True North Compliance Services, Inc. 15375 Barranca Pkwy, Suite A202, Irvine, CA 92618 T / 562. 733.8030 !PROJECT STRUCTURAL CALCULATIONS IISSUE DATE 01/05/23 Description: INTERIOR REMODEL R3 Duplex w/ ADU Client: 1276 Pine Ave Venture, LLC Name: 1276 Pine Ave Remodel Minor Remodel to Modify for Stairway Paul Longton, Architect Existing Duplex DESIGN CRITERIA Building Type: Bearing wall system Construction: Stud walls, sawn lumber wood timbers, plywood sheathing RECEIVE&E JUN 5 2023 Swanson & Assoc. Engineering is the original EOR for the existing bui lding, REF: Codes: 2022 California Building Code ASCE 07-16, 2018 NDS CITY OF CARLSBAD BUILDING DIVISION Carlsbad 12-0053 Summary: Wood: Studs -Stud grade, Standard & btr. Posts -Standard & better Beams -DF#2 or better Joists -I -Joists GLBs -24F-1.8E LSL -laminated strand rims and beams LVL -laminated veneer microlam beams and joists PSL -parallel strand beams Existing Foundation is satisfactory for new loads. No new Wind or Seismic loads. Soils & bearing: P/T slab design by others .-B-UI.-LD_'l._Ni_G_L_OA_D_S----------------------~!) t Roof Loads Roofing (tile) & 30% Solar PV Sheathing Rafters or trusses Ceiling psf 10.1 1.4 3.2 2.2 Misc. & insulation 1.1 Total Roof DL ............................................................ 18.0 psf Roof Live Load (less than 6:12 pitch) ................... 20 psf Roof Live Load (6:12 pitch or steeper)................ 18 psf Roof Live Load (8:12 pitch or st eeper)................ 16 psf Exterior Walls psf Foam & stucco or siding 7.0 Studs 1.1 Gypsum board 2.2 Misc. & insulation 1.7 Total Wall DL ............................................................ 12.0 psf Floor Loads Floor Finish (carpet) Sheathing Joists Ceiling psf 1.2 2.0 2.6 2.6 Misc. & insulation 3.6 Total Floor DL .......................... 12.0 psf Floor Live Load ......................... 40 psf Deck/Balcony Live Load .......... 60 psf Exit Live Load ........................... 100 psf Interior Walls Shear panel Studs Gypsum board Misc. & insulat ion Total Wall DL ........................... . psf 1.1 4.4 2.5 8.0 psf Swanson & Associates 17055 Via Del Campo, Suite 100, San Diego, CA 92127 -0 psf 2.0 1.1 4.4 2.5 10.0 psf (858) 487-7600 Moment Nominal I Actual Area Section of Size Size Modulus Inertia (b) x (d) (A) (S) (I) inches in2 in3 in~ 2x4 I 1.5 x 3.5 5.25 3.06 5.36 Section Properties & Design Loads Roof Loads LDF= 1.25 Allowable Shear Moment (lbs) (lb-ft) 788 211 Floor Loads LDF= 1.00 Allowable Shear Moment (lbs) (lb-ft) I 3 ft. 630 169 4ft, (w) Allowable Uniform Loads (pit) Span in feet for beam or joist sizes Normal duration, Laterally fully braced, repetitive member increase for 2x members. 5 ft, 6 ft. 7 ft, 8 ft. 9 ft. 10 ft, 11 ft. 12 ft, 13 ft. 14 ft. 15 ft. 16 ft. 17 ft. 11 8 7 5 4 3 3 i@@#f4Y@i Wfil.&!K~JaJ. !l'fa4~ rni~cn 'f1241(€t 11fffeae1wt&tef ¥!§,fi'w~~i&@ 29 23 19 15 13 2019 CBC 18 ft, 19 ft. 2 11 2 9 2x8 1.5 x 7.25 10.88 13.14 47.63 1,631 1,700 1,305 1,360 1,094 )ffi/lf.l¾fj~' ,s;,:,;,:,❖: 53 43 35 30 25 21 :m;m:itrnrnm tE?:W.l:l~Jf: ati@ lttm 1:r.1t.11r,i ilt!mMWffi!tJt 11-:Wl'-I~l~ 1,094 820 ·1!a½ ~•. -~ .\h .... •.•.❖:...:-•.. ~~'! { ~~,.:.-:. }s-;;.;.;...f •. ::..J: 2x12 1.5 X 11.25 16.88 31.64 177.98 2,531 3,411 2,025 2,729 1,094 820 656 Mwi@Wt-iiih it¥~J1k;w Aft..$.W i:M,..i~~§: ii~W.1.'.ik il!ia:1&tW$$.}: \i~d$id'.~t~'i%i 1,094 820 656 4x4 3.5 X 3.5 12.25 7.15 12.51 1,838 1,005 1,470 804 t1-f lrn@it~/H@ fffil~l¾&~f n,111 til&Ml fa!~IMl lf~,J%J.~W11} f*li}imi.IfKl1 ~ 4x8 3.5 X 7.25 25.38 30.66 111.15 3,806 3,737 3,045 2,989 2,188 t"WW@i,(&Viff ~~wl%~~, ~W%ffe tt~mrn :r.~gam;n ¥\l~:fil@t~;w,~~r 1*M?@M'~¥.fi 1.¥~1~ ~ .. --... ----w 4x12 3.5 X 11.25 39.38 73.83 415.28 5,906 8,459 4,725 6,768 4,375 3,281 l:®/fiij \t;Jt'iWKC'@~'.¥'.tf&'5 ¥3/Tul'. l'irtff 1½fi;1§' EeK1WF(~t@§Wffit;lWl~'MY 4,375 3,281 ~·625, 4x16 3.5 X 15.25 53.38 135.66 1,034.42 8,006 14,131 6,405 11,305 4,375 3,281 2,625 2,188 f ti@M~J.f.@JN tt!.?l:i.%~ M&!.ft @H£tB i1~W!W1 =@Jlffl@'JJJ.lffi rnmreu:t~~.$ if.1 6x6 5.5 X 5.5 30.25 27.73 76.26 4,285 3,466 3,428 2,773 ~ ,,,,,,&wmL& .;..g;§;}ij.J;ar f~M[: {~($.$1 $.}l!Jkl l~M,k@i!mi ;1~m[½RJft.g],,.3....;•....;43_8_i~~~ 6x10 5.5 x 9.5 52.25 82.73 392.96 7,402 11,634 5,922 9,307 6,875t.4)91\~F tlilii~f~!faH:! ii!~Mif:i?:l l&~ltl if!im IllMl!t 1)~;tfffillni§Iff i!IJJi.ftW.Jlffi! 6,875*{Wt'<1.12511~ 15 12 10 9 34 144 120 101 86 f~l~~;~~~t.~:~~<N:❖;~:~~-:~;-;-:,;~~~:I ,·.w,-;;•,••~-~t-~-.;;m,, , ... ~.:,!,~!.:~~~" }_!,;~/ .,:.,~.?..:.,. }!,;,!:.~!,, ,~.~~~-~?.,-"...._~;~.~-~½ ~~:.!;;~,_},~;;~,,., 6,875 5,156 4,125 3,438 2,946i~ i@fM~~tiW fRfaiKJ~§J i~;Q;;;;P.'' tt4.ii.i~1 :,Z~9[1~~ 1i.i'\!l~Ml<1:l~l:Jii.?t:.g('E:~fagf~#'Qqf 6,875 5,156 4,125 3,438 2,946 2p8 2,292 2,063 1¼" Timberstrand LSL rim board & 1¾" Timberstrand LSL tMi:Ui!~t Jim.lJlf!Mrn H~ID !~Jilli .t!lf;_imf ti~1P!~W.K r.f&~WW.f.JfA% 1,035 v~• v•v ~~ vvv v~v ............ . i l¼x14 LSL 1.25 x 14.0 17.50 40.83 285.83 6,198 7,129 4,958 5,703 1,035 ---· --·- iH{fi:1.@ff.@1 !tfllffK1i f~qf; t~tii :r§iw w~iwif11r11 iw1itt@.lt~i.ffi. 1.o35 I I I .,,_. ... ., ...... """ ...... .... """ 777 621 518 444 388 345 311 mtJ!ijJ@i~,M 191 157 128 105 88 74 63 777 621 518 444 388 345 311 282 259 239 222 rim 173 144 121 103 777 '-?1 ,;1R .4'1,1 ~RR ~.4,; ~11 ?R? 259 239 222 207 194 183 173 154 l¾x11f LSL 1.75 x 11.88 20.78 41.13 244.21 5,368 9,971 4,295 7,977 1,838 • -----· --· fffttt\tr~@ ffi'.m'.ilt#J§ \:~~ F&t#¥.11~l?li t¥.~~'.tkffii~~ IIef:~ifJ.!t.~i 1,838 •,~, v •,•w 747 'vv vv7 v•~ v v• vv• , 1¾x16 LSL 1.75 x 16.0 28.00 74.67 597.33 7,233 17,611 5,787 14,089 1,838 1,378 1,103 919 788 689 613 551 501 404 318 254 207 170 142 120 102 I ~711 110.1 010 7RII ,;110 ,;n ,;,;1 501 459 424 394 339 279 233 196 167 1,378 1,103 919 788 689 613 551 501 459 424 394 368 345 324 293 249 3½" nmberstr011~ LSI. I 3½x4t LSL 3.5 x 4.38 15.31 11.17 24.42 5,423 2,170 4,339 1,736 /1.§J~)!i®if.J 484 280 176 118 83 60 45 35 28 22 18 l@J!Rllt@!i K~~JJ.!tmi \Ji~ t!ll~@ J#Jt~I@ ;@'&IJJJill~ iH.IJ1J~~!ffi '&.~1htl#ittJ~l 556 350 235 165 120 90 7o 55 44 36 15 12 10 9 29 24 21 18 3½x7¼ LSL 3.5 x 7.25 25.38 30.66 111.15 8,987 5,687 7,190 4,550 2,485 1,864 ft~-~%$.lfJ 538 378 275 207 159 125 100 82 i'MiE:IJ~:l ll¥fiii~li M§f.WI M!ll:2! :l![fJ!f fil½\rliH:?!1£.'.1' l!illWiilllli 2,485 1,864 ~1J91 '7z43ff:J.j~fj,;~fnijtft 463 348 268 211 169 137 , 3½x9½ LSL 3.5 x 9.5 33.25 52.65 250.07 8,590 13,027 6,872 10,422 6,300 4,725[~1~~.i.~!t.¾1ft1~f%®l 980 714 537 413 325 260 212 iili~~11¥!@lr ffirili~ tl11@l llii1 filt~mWf }~1&ltlii@l 11~Jfiltfi.Jjfl 6,300 4,725 ~ris~T501l:~1ftli~f:1Mi'fl1®tl 891 687 540 432 352 ' 3½x11t LSL 3.5 x 11.88 41.56 82.26 488.41 10,737 19,941 8,590 15,953 6,300 4,725 3,780 3,150 ~tl~lf1~l.itf tmt$iliU7,~~ 1,048 808 635 509 413 f •,,~···~;:~-"•'''~,X• •,,•,?,~',;::>,•.:zc• .Y❖,:i'>""•'❖ '/:':>.'•'<❖?i,',W ¾:),'c;.❖'•X•W.«•· !(.•❖.•.,m•;m. »i.W.«:ll'~ ,<,•.•,,w(m,p;:,,,~:',;l;:;=/ ~~-=,:;x, ,» -'"'t}.:/i~/:$;,,.❖';l°(~:>,W,~~'¢',i";i:,',;X« t-it*!!idt rna:rtm a~mr a~~ :1-1:iji.EfJM ~JmM~~-a2i.1.tt1irffl'. 6,300 4,725 3,780 3,150 2.700 2.363 2,100 1:ml.lt1~~~i~~li\1~~~m. 833 678 3½x16 LSL 3.5 x 16.0 56.00 149.33 1,194.67 14,467 35,222 11,573 28,178 6,300 4,725 3,780 3,150 2,700 2,363 2,100 1,890 1,718 f@ffi~'ifli§~lfo.Wj~Qi~~~Q?.:1 67 56 47 40 113 94 79 68 174 145 123 104 290 242 203 173 341 284 239 203 558 465 392 333 833 695 585 498 1. At roof loading conditions where shear or bending governs, use a 1.25 LDF adjustment to the above values. 2. At roof loading conditions where deflection governs, use a 1.15 deflection adjustment factor to the above values. 3. Shading in t he span / allowable uniform load table Indicates that bending (F'b) governs. Shear governs to the left of the shading, and deflection governs to the right. I CJ) ~ n -+ o· :::s -0 ., 0 "'O ~ ., -+ ~- II) Q,, r:::J ~ II) 1.0· :::s r 0 C a. II) .... N ---1 0- :P. ~ ~ ):,. ~ 70 ~ 3 0 a. !?. 0 ..... ....... 0 1.11 ....... N lw □ 1276 Pine Ave Remodel 01/05/23 ·~1_FL_o_o_R_F_R_A_M_I_N_G_,_P_i_ne_A_ve_R_em_o_d_e_1 ________________ ____,I 0 Typical Floor Framing: I-joists per manufacture' s span tables See plans & calcs pg. 4 for alternates 2022 CBC/CRC, Basic Load Combinations Note: Loading is derived from a reversed/mirrored condition B-1 wl (xs.2) = w2 (x~2) = P (x=2) = Rl = R2 = Moment= Deflection: B-2 w= R1 = R2 = Moment= Deflection: B-3 w= P (x=3.4) = Rl = R2 = Moment = Deflection: 10.9' Span Around NEW STAIRWAY (roof) (wall) (9)(8) (9)(8) (floor) (misc.) + (15/2)(52) + 15 = + (11/2)(52) + 15 = (7 /2x4/2)(52) + 20 [Top of stairs] = 477 plf 373 plf 384 lbs (Critical Rl / 1.00 LDF = 2,535 lbs) Rl (max.) = 2,535 lbs (Critical R2 / 1.00 LDF = 2,122 lbs) R2 (max.) = 2,122 lbs (Critical M / 1.00 LDF = 6,038#ft) Moment (max.) = 6,038#ft A TL= 0.22" (L/602) ALL= 0.13" (L/997) p w1 l w2 rmm, I I I I I I I I I I I I I I I 11 f R1 l R2 ~ X • 1¾x14 LSL 7.2' Span Around NEW STAIRWAY abv Living (roof) (wall) (9)(8) (floor) + (12/2)(52) (misc.) + 15 = 399 plf (Critical R1 / 1.00 LDF = 1,436 lbs) R1 (max.) = 1,436 lbs (Critical R2 / 1.00 LDF = 1,436 lbs) R2 (max.) = 1,436 lbs (Critical M / 1.00 LDF = 2,586#ft) Moment (max.) = 2,586#ft ATL = 0.04" (L/2,150) ALL= 0.02" (L/3,574) 15.5' Span (roof) (wall) w 1! 1111111111111 I I I I I I I I I 1 fRl lR2 1¾x14 LSL Around Stairs (floor) (1.4)(52) (misc.) + 20 = 93 plf w lp '"11 )TTI) ")) )""))'"")) .... )ITT) I .... II I,...,) )M'T))'"') )I 1436 [Load from B-2] = 1,436 lbs lR1 lR2 ~ X lo (Critical Rl / 1.00 LDF = 1,841 lbs) Rl (max.) = 1,841 lbs (Critical R2 / 1.00 LDF = 1,034 lbs) R2 (max.) = 1,034 lbs (Critical M / 1.00 LDF = 5,764#ft) Moment (max.) = 5,764#ft 3½x14 LSL 6TL = 0.20" (L/930) ALL= 0.12" (L/1,543) 1276 Pine Ave Remodel 01/05/23 FLOOR FRAMING, Pine Ave Remodel (Continued) '47 _________ L:_J B-4 w= Rl = R2 = Moment= Deflection: B-5 wl (xs.5.4) = Pl (x=2.1) = w(cant) = P3 (x=6.3) = Rl = R2 = Moment= Deflection: 5.4' Span New Flush beam across hallway (roof) (wall) (floor) (30/2)(52) (misc.) + 20 = 800 plf (Critical R1 / 1.00 LDF = 2,160 lbs) Rl (max.) = 2,160 lbs (Critical R2 / 1.00 LDF = 2,160 lbs) R2 (max.) = 2,160 lbs w O I I I I I I I I 111111111111111 r R1 r R2 (Critical M / 1.00 LDF = 2,916#ft) Moment (max.) = 2,916#ft 3½x14 LSL LiTL = 0.01" (L/5,083) .t.LL = 0.01" (L/6,777) 5.4' Span w/ 1' Right Cantilever ADU BR. 1 above doorway (roof) (wall) (floor) (misc.) (1.3)(52) + 20 = 88 plf 2535 [Hanger from B-1] = 2,535 lbs 20 = 20 plf 1 P1jP2 P3-P4 W , WC! 0111111111111111111111,rrrn TR1 lR2 ,.L X .. 2160 [Reaction From B-4) = 2,160 lbs (Critical R1 / 1.00 LDF = 1,694 lbs) R1 (max.) = 1,694 lbs (Critical R2 / 1.00 LDF = 3,764 lbs) R2 (max.) = 3,764 lbs (Critical M / 1.00 LDF = 3,364#ft) Moment (max.) = 3,364#ft 3½x14 LSL Cantilever Deflection: .t.TL = 0.01" (L/5,718) ALL= 0.01" (L/8,329) LiTL = -0.01" (2L/4,640) .t. LL= 0.00" (2L/5,407) 1276 Pine Ave 01/05/23 CONVENTIONAL FOUNDATION Existing Footings & remodel '57 '--------------' L.J UNIFORM LOADS-Capacity based on soil bearing. (200 psf increase for 24" deep) Soil bearing pressure= 12" wide x up to 18" deep 24" deep CONCENTRATED LOADS to footings Soil bearing pressure= Footing Size .b. Brg Area 5" Slab ( no ftg) 5" 0.99 sf 12"x 15" Cont. 12"x18" Cont. 12"x24" Cont. 15"x18" Cont. 15"x24" Cont. 18" Sq. Pad 24" Sq. Pad Beam/ Description B-5 Beam (Rl) 22" 3.96 sf 25" 4.46 sf 31" 5.46 sf 25" 5.57 sf 31" 22" 22" 6.82 sf 2.25 sf 4.00 sf B-5 Beam on existing ftg. A II other new beams (Max Load) 2,000 psf 2,000 plf 2,200 plf 2,000 psf 1,983 lbs 7,917 lbs 8,917 lbs 12,008 lbs 11,146 lbs 15,010 lbs 4,500 lbs 8,000 lbs Load (lbs) 1,694 5,293 4,369 Footing (e) 5" slab OK 12"x15" Cont. 12"xl5" Cont. The 8-5 Load {Rl) is spread over sufficient distance with a block to accept the 5" slab 1276 Pine ADU 05/01/23 Handrail Check , ~ ....._ ________________________________ 2_0_2_2_C_RC__, ~ Connection--Wall mounted Handrail 2001b any direction CBC Load Duration Factor CD ( wood connectors) Total qty of connectors Lag Screw Pullout Required Capacity T = 200/2/CD Design pullout strength per inch for no. 8 wood screw NDS Table 11.2B Minimum Embedment Capacity of Anchorage= embed x Table value (per inch) = 1.60 = 2 no. 8 Wood Screws = 62.50 lbs. total = 112.00 lb per inch = 1.50 inch = 168.00 > 62.50 !Min. (2) no. 8 wood screws into blocking BUILDING ENERGY ANALYSIS REPORT PROJECT: 1276 Pine Ave ADU 1276 Pine Ave Carlsbad, CA 92008 Project Designer: Studio 4 2909 Mesa Drivve Oceanside, CA 92054 760-458-0987 Report Prepared by: Douglas G. Williams CEA HERS Rater WillCalc 2085 James Gaynor St. Fallbrook, CA 92028 760-846-6480 Doug@WillCalc.com Job Number: 22513 Date: 1 /12/'t. PC2023-0006 1276 PINE AVE The EnergyPro computer program has been used to perform the calculatiorn authorized by the California.Energy Commission for use with both the Rer 1274 PINE (MAIN SFD) AND 1276 PINE \ADU): ENLARGE ADU BY (438 SF) AND REDUCE EXISTING SFD FOOTPRINT (438 SF) CREATING 2 NEW BEDROOMS IN This program developed by EnergySo 2050205600 2/14/2023 PC2023-0006 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Forni CF1 R-PRF-01-E Certificate of Compliance 3 Form MF1 R Mandatory Measures Summary 13 HVAC System Heating and Cooling Loads Summary 18 .J r ' .. 1 J t CERTIFICATE OF COMPLIANCE • RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 1276 Pine Ave ADU Calculation Description: Title 24 Analysis GENERAL INFORMATION 01 Project Name 1276 Pine Ave ADU 02 Run Title Title 24 Analysis 03 Project Location 1276 Pine Ave 04 City Carlsbad 06 Zip code 92008 08 Climate Zone 7 10 Building Type Single family 12 Project Scope Addition and/or Alteration 14 Addition Cond. Floor Area (ft2) 0 16 Existing Cond. Floor Area (ft2) 1078 18 Total Cond. Floor Area (ft2) 1078 20 ADU Bedroom Count n/a COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 Building does not require field testing or HERS verification 03 This building incorporates one or more Special Features shown below Calculation Date/Time: 2023-0l-12T14:27:19-08:00 Input File Name: 23125 1276 Pine.ribd22x 05 Standards Version 2022 07 Software Version EnergyPro 9.0 09 front Orientation (deg/ Cardinal) 320 11 Number of Dwelling Units 1 13 Number of Bedrooms 4 15 Number of Stories 1 17 Fenestration Average U-factor 0 19 Glazing Percentage (%) 27.70% Registration Number: Registration Date/Time: I-IERS Provider: 223-P010004913A-000-000-0000000-0000 2023-01-12 16:44:48 (Page 1 of 10) CalCERTS inc. CA Building Energy Efficiency Standards -2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-01-12 14:27:45 Schema Version: rev 20220901 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 1276 Pine Ave ADU Calculation Description: Title 24 Analysis ENERGY USE SUMMARY Standard Design Source Standard Design TDV Energy Calculation Date/Time: 2023-0l-12T14:27:19-08:00 Input File Name: 23125 1276 Pine.ribd22x Proposed Design Source Proposed Design TDV Energy Energy Use Energy (EDRl ) (kBtu/ft2 -yr) (EDR2} {kTDV/ft2 -yr) Energy (EDRl} (kBtu/ft2 -yr) (EDR2) (kTDV/ft2 -yr) Space Heating 0 1.26 0 1.19 Space Cooling 0 26.42 0 25.09 IAQ Ventilation 0 0 0 0 Water Heating 0 37.59 0 37.59 Self Utilization/Flexibility Credit Efficiency Compliance 0 Total 65.27 0 63.87 Photovoltaics 0 0 Battery 0 Flexibility Indoor lighting 0 8.61 0 8.61 Appl. & Cooking 0 22.87 0 22.87 Plug Loads 0 62.52 0 62.52 Outdoor lighting 0 1.88 0 1.88 TOTAL COMPLIANCE 0 161.15 0 159.75 Compliance Margin (EDRl) 0 0 0 0 0 Registration Number: 223-P010004913A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2023-01-12 16:44:48 (Page 2 of 10) Compliance Margin (EDR2} 0.07 1.33 0 0 1.4 CalCERTS inc. CA Building Energy Efficiency Standards -2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-01-12 14:27:45 Schema Version: rev 20220901 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 1276 Pine Ave ADU Calculation Description: Title 24 Analysis ENERGY USE INTENSITY Calculation Date/Time: 2023-0l-12T14:27:19-08:00 Input File Name: 23125 1276 Pine.ribd22x (Page 3 of 10) Standard Design (kBtu/ft2 -yr ) Proposed Design (kBtu/ft2 -yr) Compliance Margin (kBtu/ft2 -yr ) Margin Percentage Gross EUl1 25.6 25.42 0.18 0.7 Net EUl2 25.6 25.42 0.18 0.7 Notes 1. Gross EUI is Energy Use Total (not Including PV) / Total Building Area. 2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED SPECIAL FEATURES The follow Ing are features that must be installed as condition for meeting the modeled energy performance forth is computer analysis. • New ductwork added Is less than 40 ft. in length HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in t he buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry ' r BUILDING • FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Number of Bedrooms Number of Zones Number of Ventilation Number of Water Units Cooling Systems Heating Systems 1276 Pine Ave ADU 1078 1 4 1 0 1 ZONE INFORMATION 01 02 03 04 OS 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Status ADU Conditioned hvacl 1078 10 DHW Sys 1 Existing Unchanged Registration Number: Registration Date/Time: I-IERS Provider: 223-P010004913A-000-000-0000000-0000 2023-01 -12 16:44:48 CalCERTS inc. CA Building Energy Efficiency Standards -2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-01-12 14:27:45 Schema Version: rev 20220901 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 1276 Pine Ave ADU Calculation Date/Time: 2023-0l-12T14:27:19-08:00 Input File Name: 23125 1276 Pine.ribd22x Calculation Description: Title 24 Analysis OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window and Tilt (deg) Wall Exceptions Door Area (ft2) DS Front Wall ADU R-13 Wall 320 Front 302 108 90 none Back Angled ADU R-13 Wall 95 Wall n/a 20 0 90 none Back Angled ADU R-13 Wall 185 Wall n/a 77 0 90 none DS Back Wall ADU R-13 Wall 140 Back 55 13.5 90 none DS Right Wall ADU R-13 Wall 230 Right 170 46.5 90 none US Front Wall ADU R-13 Wall 320 Front 275 84 90 none US Right Wall ADU R-13 Wall 230 Right 269 46.5 90 none ADU» Garage ADU R-13 Walll n/a n/a 290 24 n/a Roof 4/12 ADU R-19 Roof Attic n/a n/a 438 n/a n/a ADU» Garage ADU R-19 Floor No 2 Crawlspace n/a n/a 30 n/a n/a OPAQUE SURFACES -CATHEDRAL CEILINGS 01 02 03 04 OS 06 07 08 09 10 11 12 Area Skylight Roof Rise (x Roof Roof Cool Name Zone Construction Azimuth Orientation (ft2) Area (ft2) in 12) Reflectance Emittance Roof Status Roof as ADU R-19 Roof No 0 n/a 103 0 0.2 0.1 0.85 No Existing Deck Attic ATTIC 01 02 03 04 OS 06 07 08 Name Construction Type Roof Rise Roof Roof Radiant Cool Roof (x in 12) Reflectance Emittance Barrier Attic ADU Attic RoofADU Ventilated 4 0.1 0.85 No No 10 Status Existing Existing Existing Existing Existing Existing Existing Existing Existing Existing 13 Verified Existing Condition No 09 Status Existing Registration Number: 223-P010004913A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2023-01-12 16:44:48 {Page 4 of 10) 11 Verified Existing Condition No No No No No No No No No No 14 Existing Construction 10 Verified Existing Condition No CalCERTS inc. CA Building Energy Efficiency Standards -2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-01-12 14:27:45 Schema Version: rev 20220901 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 1276 Pine Ave ADU Calculation Date/rime: 2023-0l-12T14:27:19-08:00 Input File Name: 23125 1276 Pine.ribd22x Calculation Description: Title 24 Analysis FENESTRATION / GLAZING 01 oz 03 04 OS 06 07 08 09 10 11 12 13 14 Orientatio Width Heigh Area U-factor El(terior Name Type Surface Azimuth (ft) t (ft} Mult. (ft2} U-factor Source SHGC SHGCSource Shading n Windowl Window DS Front Front 320 1 42 0.58 Table 0.65 Table Bug Screen Wall 110.6-A 110.6-B DoorD Window DS Front Front 320 1 24 0.58 Table 0.65 Table Bug Screen Wall 110.6-A 110.6-B Window 1 Window DS Front Front 320 1 42 0.58 Table 0.65 Table Bug Screen Wall 110.6-A 110.6-B Window6 Window DS Back Wall Back 140 1 13.5 0.58 Table 0.65 Table Bug Screen 110.6-A 110.6-B Window3 Window DS Right Right 230 1 36 0.58 Table 0.65 Table Bug Screen Wall 110.6-A 110.6-B DS Right : Table -Table Window2 Window Wall Right 230 1 10.5 0.58 110.6-A 0.65 110.6-B Bug Screen Window12 Window US Front Front 320 1 42 0.58 Table 0.65 Table Bug Screen Wall 110.6-A 110.6-B Window 12 Window US Front Front 320 1 42 0.58 Table 0.65 Table Bug Screen Wall 110.6-A 110.6-B Window11 Window US Right Right 230 1 36 0.58 Table 0.65 Table Bug Screen Wall 110.6-A 110.6-B Windowl0 Window US Right Right 230 1 10.5 0.58 Table 0.65 Table Bug Screen Wall 110.6-A 110.6-B Registration Number: Registration Date/Time: HERS Provider: 223-P010004913A-000-000-0000000-0000 2023-01-12 16:44:48 (Page 5 of 10) 15 16 Verified Status El(isting Condition Existing No Existing No Existing No Existing No Existing No Existing No Existing No Existing No Existing No Existing No CalCERTS inc. CA Building Energy Efficiency Standards -2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-01-12 14:27:45 Schema Version: rev 20220901 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 1276 Pine Ave ADU Calculation Date/Time: 2023-01-12T14:27:19-08:00 Input File Name: 23125 1276 Pine.ribd22x (Page 6 of 10) Calculation Description: Title 24 Analysis OPAQUE DOORS 01 02 Name Side of Building Door J ADU » Garage SIAB FLOORS 01 02 03 04 Name Zone Area (ft2} Perimeter (ft) Slab-on-Grade ADU 640 55 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 Construction Name Surface Type Construction Type R-13 Wall Exterior Walls Wood Framed Wall Wood Framed R-19 Roof No Attic Cathedral Ceilings Ceiling R-13 Walll Interior Walls Wood Framed Wall Registration Number: 223-P010004913A-000-000-0000000-0000 CA Building Energy Efficiency Standards -2022 Residential Compliance 03 04 Area (ft2) U-factor 24 0.5 05 06 07 Edge lnsul. Edge lnsul. R-value and R-value and Carpeted Fraction Depth Depth none 0 80% 04 OS 06 Total Cavity Interior/ Exterior Framing R-value Continuous R-value 2x4@ 16 in. 0. C. R-13 None/ None 2x8@ 16 in. 0. C. R-19 None/ None 2x4 @ 16 in. 0. C. R-13 None/ None Registration Date/Time: 2023-01-1216:44:48 Report Version: 2022.0.000 Schema Version: rev 20220901 OS 06 Status Verified Existing Condition Existing No 08 09 10 Verified Existing Heated Status Condition No Existing No 07 08 U-factor Assembly Layers Inside Finish: Gypsum Board 0.101 Cavity / Frame: R-13 / 2x4 Exterior Finish: 3 Coat Stucco Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood 0.054 Siding/sheathing/decking Cavity/ Frame: R-19 / 2x8 Inside Finish: Gypsum Board Inside Finish: Gypsum Board 0.092 Cavity/ Frame: R-13 / 2x4 Other Side Finish: Gypsum Board HERS Provider: GalCERTS inc. Report Generated: 2023-01-12 14:27:45 CERTIFICATE OF COMPLIANCE • RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 1276 Pine Ave ADU Calculation Date/rime: 2023-0l-12T14:27:19-08:00 (Page 7 of 10) Calculation Description: Title 24 Analysis Input File Name: 23125 1276 Pine.ribd22x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Total Cavity Interior / EKterior Construction Name Surface Type Construction Type Framing R-value Continuous U-factor Assembly Layers R-value Roofing: Light Roof (Asphalt Shingle) Attic RoofADU Attic Roofs Wood Framed 2x4 @ 24 in. 0. C. R-0 None/ None 0.644 Roof Deck: Wood Ceiling Siding/sheathing/decking cavity/ Frame: no insui. / 2x4 Ceilings (below Wood Framed Over Ceiling Joists: R-9.9 insui. R-19 Roof Attic attic) Ceiling 2x4@ 24 in. o. C. R-19 None/ None 0.049 Cavity/ Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board Floor Surface: Carpeted R-19 Floor No Floor Deck: Wood Interior Floors Wood Framed Floor 2X8 @ 16 in. 0. C. R-19 None/ None 0.046 Siding/sheathing/decking Crawlspace Cavity/ Frame: R-19 / 21<8 Ceiling Below Finish: Gypsum Board BUILDING ENVELOPE -HERS VERIFICATION ' 01 02 03 04 05 Quality Insulation Installation (QII) High R-value Spray Foam Insulation Building Envelope Air leakage CFM50 CFMS0 Not Required Not Required N/A n/a n/a WATER HEATING SYSTEMS 01 02 03 04 OS 06 07 08 09 10 11 12 Distribution Water Heater Number of Solar Heating Compact HERS Water Heater Verified El<isting Water Name System Type Type Name Units System Distribution Verification Name(#) Status Existing Heating Condition System Domestic DHW Heater DHW Heater DHWSysl Hot Water Standard 1 n/a None n/a Existing No (DHW) 1 1(1) Registration Number: 223-P010004913A-000-000-0000000-0000 Registration Date/Time: 2023-01-12 16:44:48 HERS Provider: CalCERTS inc. CA Building Energy Efficiency Standards• 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-01-12 14:27:45 Schema Version: rev 20220901 CERTIFICATE OF COMPLIANCE· RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 1276 Pine Ave ADU Calculation Date/Time: 2023-01-12T14:27:19-08:00 Input File Name: 23125 1276 Pine.ribd22x (Page 8 of 10) Calculation Description: Title 24 Analysis WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Heating Heating Input Tank Standby 1st Hr. Verified #of Tank Vol. Rated Insulation Loss or Name Element Tank Type Units (gal) Efficiency Efficiency Input Type Rating or R-value Recovery Rating or Tank location Status Existing Type Type Pilot (Int/Ext) Eff Flow Rate Condition DHW Gas Consumer 1 0 UEF Heater 1 Instantaneous 0.82 Btu/Hr 200000 0 n/a Existing No WATER HEATING -HERS VERIFICATION 01 02 03 04 OS 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Recirculation Control Shower Drain Water Heat Type Recovery DHW Sys 1 -1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Heating Unit Heating Cooling Unit Cooling Distribution Required Verified Existing HVAC Name System Type Name Equipment Name Equipment Fan Name Name Thermostat Status Existing System Count Count Type Condition Heating and Heating Cooling Air hvacl cooling Component 1 Component 1 HVAC Fan 1 Distribution n/a Existing No system other 1 1 System 1 HVAC • HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Heating Efficiency Heating Component 1 Central gas furnace 1 AFUE-80 Registration Number: 223-P010004913A-000-000-0000000-0000 Registration Date/Time: 2023-01-12 16:44:48 HERS Provider: CalCERTS inc. CA Building Energy Efficiency Standards -2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-01-12 14:27:45 Schema Version: rev 20220901 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 1276 Pine Ave ADU Calculation Date/Time: 2023-0l-12T14:27:19-08:00 Input File Name: 23125 1276 Pine.ribd22x (Page 9 of 10) Calculation Description: Title 24 Analysis HVAC -COOLING UNIT TYPES 01 oz 03 04 05 06 07 08 09 Name System Type Number of Units Efficiency Metric Efficiency Efficiency Zonally Controlled Mulit-speed HERS Verification EER/EER2/CEER SEER/SEER2 Compressor Cooling Cooling Central split AC 1 EER/SEER 11.7 14 Not Zonal Single Speed Component Component 1 1-hers-cool HVAC -DISTRIBUTION SYSTEMS 01 02 03 04 OS 06 07 08 09 10 11 12 13 14 15 16 Duct Ins. Duct Surface Area R-value Location HERS Verified Existing New Ducts Name Type Design Type Bypass Duct Duct Leakage Verification Status Existing Distribution 25 ft Suppl Retur Suppl Retur Suppl Retur Condition system y n y n y -n Air Existing Air Distribution Unconditio Non-R-6 R-6 Atti Attl n/a n/a No Bypass (not Distribution Existing+ No No System 1 ned attic Verified C ,c ' D.uct specified) f system New ' hhers-dlst HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS -HERS VERIFICATION 01 Name HVAC Fan 1-hers-fan HERS RATER VERIFICATION OF EXISTING CONDITIONS Registration Number: . 223-P010004913A-OOO-0OO-OO00OOO-OOO0 CA Building Energy Efficiency Standards -2022 Residential Compliance 02 Verified Fan Watt Draw Not Required Registration Date/Time: 2023-01-1216:44:48 Report Version: 2022.0.000 Schema Version: rev 20220901 03 Required Fan Efficacy (Watts/CFM) 0 -HERS Provider: CalCERTS inc. Report Generated: 2023-01-12 14:27:45 CERTIFICATE OF COMPLIANCE · RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 1276 Pine Ave ADU Calculation Description: Title 24 Analysis Calculation Date/Time: 2023-01-12T14:27:19-08:00 Input File Name: 23125 1276 Pine.ribd22x (Page 10 of 10) DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Douglas Williams q;~ cu,~ Company: Signature Date: ~ WillCalc 2023-01 -1 2 15:43:09 CABEc Address: CEA/ HERS Certification Identification (If applicable): 2085 James Gaynor Street CEA R19-07-30022 ,.tb .... ~ .............. , p""'~E "fV (,.,,,,,,..,,., Eillilllili•ID~liil ~--!~l,!liil City/State/Zip: Phone: Fallbrook, CA 92028 760-846-6480 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design Identified on this Certificate of Compliance. 2. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features Identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Paul Longton Responsible Designer Signature: ~~~~ Company: Date Signed: Studio 4 Architects 2023-01-1216:44:48 Address: License: 2909 Mesa Drive C18757 City/State/Zip: Phone: Oceanside, CA 92054 760-722-4904 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 223-P010004913A--O00-000-00OOOO0--OOO0 Registration Date/Time: 2023-01-12 16:44:48 CA Building Energy Efficiency Standards -2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 II . :, [!)_ • Easy to Verify at CalCERTS.com HERS Provider: CalCERTS inc. Report Generated: 2023-01-12 14:27:4S 2022 Single°Family Residential Mandatory Requirements Summary NOTE: Single-family residential buildings subject to the Energy Codes must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. (04/2022) Buildina Enveloce· § 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 CFM per square foot or less when tested oer NFRC-400, ASTM E283, or AAMNWDMNCSA 101 /I.S.2/A440-2011. * § 110.6(a)5: Labeling. Fenestration products and exterior doors must have a label meeting the requirements of§ 10-111 (a). § 110.6(b): · Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from Tables 110.6-A, 110.6-B, or JA4.5 for exterior doors. They must be caulked and/or weather-striooed. • § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, aasketed, or weather strinned. § 110.8(a): Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household Goods and Services (BHGS). § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of§ 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of§ 110.8(i) and be labeled per §10-113 when the installation of a cool roof ls specified on the CF1R. § 110.80): Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Roof Deck, Ceiling and Rafter Roof Insulation. Roof decks in newly constructed attics in climate zones 4 and 8-16 area-weighted average U-factor not exceeding U-0.184. Ceiling and rafter roofs minimum R-22 insulation in wood-frame ceiling; or area-weighted average § 150.0(a): U-factor must not exceed 0.043. Rafter roof alterations minimum R-19 or area-weighted average U-factor of 0.054 or less. Attic access doors must have permanently attached insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a roof or ceiling which is sealed to limit infiltration and exfiltration as specified in~ 110.7, includina but not limited to placina insulation either above or below the roof deck or on too of a drywall ceilina. • § 150.0(b): Loose-fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood § 150.0(c): framing or have a U-factor of 0.071 or less. Opaque non-framed assemblies must have an overall assembly U-factor not exceeding 0.102. Masonrv walls must meet Tables 150.1-A or B. • § 150.0(d): Raised-floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor. • Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone § 150.0(~: without facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of§ 110.8(g). Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class 11 § 150.0(g)1: vapor retarder. This requirement also applies to controlled ventilation crawl space for buildings complying with the exception to &150.0(d). Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of § 150.0(g)2: all insulation in all exterior walls, vented attics, and unvented attics with air-permeable insulation. Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have § 150.0(q): a maximum U-factor of 0.45; or area-weighted average U-factor of all fenestration must not exceed 0.45. • Fireplaces, Decorative Gas Acoliances, and Gas Loa: § 110.5(e) Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces. § 150.0(e)1: Closable Doors. Masonry or factory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)2: Combustion Intake. Masonry or factory-built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is eauiooed with a readily accessible, operable, and tiaht-fittina dam□er or combustion-air control device. § 150.0(e)3: Flue Damper. Masonrv or factorv-built fireplaces must have a flue damper with a readily accessible control. • Soace Conditionina Water Heatina and Plumbina System· ' ' § 110.0-§ 110.3: Certification. Heating, ventilation, and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other reaulated appliances must be certified bv the manufacturer to the California Enerov Commission.* § 110.2{a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-N. • Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance § 110.2(b): heaters must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut-on temperature for compression heating is higher than the cut-on temperature for supplementary heating, and the cut-off temoerature for comoression heatina is hiaher than the cut-off temperature for supplementarv healina. • § 110.2(c): Thermostats. All healing or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat. • Insulation. Unfired service water heater storage tanks and solar water-heating backup tanks must have adequate insulation, or tank & 110.3(c)3: surface heat loss rating. § 110.3(c)6: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with hose bibbs or other fittinas on both cold and hot water lines to allow for flushina the water heater when the valves are closed. 5/6/22 2022 SinglenF amily Residential Mandatory Requirements Summary Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces; household cooking appliances § 110.5: (except appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour); and pool and spa heaters. • Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook, § 150.0{h)1: Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards Manual; or the ACCA Manual J using design conditions specified in§ 150.0(h)2. § 150.0(h)3A: Clearances. Air conditioner and heat pump outdoor condensing units must have a clearance of at least five feet from the outlet of any dryer. § 150.0(h)3B: Liquid Line Drier. Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the manufacturer's instructions. Water Piping, Solar Water-heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water § 150.0(j)1: piping must be insulated as specified in § 609.11 of the California Plum bin a Code. • . Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment' § 150.0U)2: maintenance, and wind as required by §120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes). Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non-crushable casing or sleeve. Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must § 150.0(n)1: designate a space at least 2.5' x 2.5' x 7' suitable for the future in~tallation of a heat pump water heater, and meet electrical and plumbing requirements, based on !lie distance between this designated space and the water heater location; and a condensate drain no more than 2" higher than the base of the water heater Solar Water-heating Systems. Solar water-heating systems and collectors must be certified and rated by the Solar Rating and § 150.0(n)3: Certification Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing agency that is approved by the executive director. Ducts and Fans· Ducts. Insulation installed on an existing space-conditioning duct must comply with§ 604.0 of the California Mechanical Code (CMC). If a § 110.8(d)3: contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air-distribution system ducts and plenums must meet CMC §§ 601.0-605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply-air and return-air ducts and plenums must be insulated to R-6.0 or higher; ducts located entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8) do not require insulation. Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be § 150.0(m)1: sealed with mastic, tape, or other duct-closure system that meets the applicable UL requirements, or aerosol sealant that meets UL 723. The combination of mastic and either mesh or tape must be used to seal openings greater than ¼", If mastic or tape is used. Building cavities, air handler support platforms, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air. Building cavities and support platforms may contain ducts; ducts installed in these spaces must not be compressed. • Factory-Fabricated Duct Systems. Factory-fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. Field-Fabricated Duct Systems. Field-fabricated duct systems must comply with applicable requirements for: pressure-sensitive tapes, § 150.0(m)3: mastics, sealants, and other requirements specified for duct construction. § 150.0(m)?: Backdraft Damper. Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers. § 150.0(m)B: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage due tosunlight, moisture, equipment maintenance, and wind. § 150.0(m)9: Insulation exposed to weather must be suitable for outdoor service (e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover). Cellular foam insulation must be protected as above or painted with a water retardant and solar radiation-resistant coatina. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner cores of flex ducts must have a non-porous layer or air barrier between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.1. Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 § 150.0(m)12: or equivalent filters. Filters for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Clean-filter pressure drop and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service. Filter racks or grilles must use gaskets, sealing, or other means to close gaps around the inserted filters to and prevents air from bypassing the filter.* 5/6/22 § 150.0(m)13: 2022 SingleaFamily Residential Mandatory Requirements Summary Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must be ~ 350 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy s 0.45 watts per CFM for gas furnace air handlers and s 0.58 watts per CFM for all others. Small duct high velocity systems must provide an airflow~ 250 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy 5 0.62 watts per CFM. Field verification testing is required in accordance with Reference Residential Appendix RA3.3. • Ventilation and Indoor Air Qualitv· § 150.0(o)1: Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in§ 150.0(o)1. • § 150.0(0)18: Central Fan Integrated (CFI) Ventilation Systems. Continuous operation of CFI air handlers is not allowed to provide the whole- dwelling unit ventilation airflow required per §150.0(o)1C. A motorized damper(s) must be installed on the ventilation duct(s) that prevents all airflow through the space conditioning duct system when the damper(s) is closed andcontrolled per §150.0(o)1 Biii&iv. CFI ventilation systems must have controls that track outdoor air ventilation run time, and either open or close the motorized damper(s) for compliance with &150.0/o)1C. Whole-Dwelling Unit Mechanical Ventilation for Single-Family Detached and townhouses . Single-family detached dwelling units, § 150.0(o)1C: and attached dwelling units not sharing ceilings or floors with other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow specified in§ 150.0(o)1Ci-iii. § 150.0(o)1G: Local Mechanical Exhaust. Kitchens and bathrooms must have local mechanical exhaust; non enclosed kitchens must have demand- controlled exhaust system meeting requirements of §150.0(o)1 Giii,enclosed kitchens and bathrooms can use demand-controlled or continuous exhaust meeting §150.0(o)1 Giii-iv. Airflow must be measured by the installer per §150.0(o)1 Gv, and rated for sound per G150.0/ol1Gvi. * § 150.0(o)1H&I: Airflow Measurement and Sound Ratings of Whole-Dwelling Unit Ventilation Systems. The airflow required per§ 150.0(o)1C must be measured by using a flow hood, flow grid, or other airflow measuring device at the fan's inlet or outlet terminals/grilles per Reference Residential Appendix RA3.7. Whole-Dwelling unit ventilation systems must be rated for sound per ASHRAE 62.2 §7.2 at no less than the minimum airflow rate required by ~150.0/ol1C. Field Verification and Diagnostic Testing. Whole-Dwelling Unit ventilation airflow, vented range hood airflow and sound rating, § 150.0(o)2: and HRV and ERV fan efficacy must be verified in accordance with Reference Residential Appendix RA3.7. Vented range hoods must be verified per Reference Residential Appendix RA3. 7.4.3 to confirm if it is rated by HVI or AHAM to comply with the airflow rates and sound requirements per §150.0(o)1 G Pool and Soa Svstems and Eauioment: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: compliance § 110.4(a): with the Appliance Efficiency Regulations and listing in MAEDbS; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating. • § 110.4(b)1: Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar healing. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time § 110.4(b)3: switch that will allow all pumps to be set or Proa rammed to run onlv during off-peak electric demand periods. ~ 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump § 150.0(p): sizing, flow rate, piping, filters, and valves. • Licihtini:r Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable § 110.9: requirements of & 110.9. • § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A, except lighting integral to exhaust fans, kitchen range hoods, bath vanity mirrors, and garage door openers; navigation lighting less than 5 watts; and lighting internal to drawers, cabinets, and linen closets with an efficacv of at least 45 lumens per watt. § 150.0(k)18: Screw based luminalres. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JAB. • § 150.0(k)1C: Recessed Down light Lumlnaires in Ceilings. Luminaires recessed into ceilings must not contain screw based sockets, must be airtight, and must be sealed with a gasket or caulk. California Electrical Code § 410.116 must also be met. § 150.0(k)1D: Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light soyrces that are not compliant with the JAB elevated temperature requirements, includina markina reauirements, must not be installed in enclosed or recessed luminaires. § 150.0(k)1E: Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or other device shall be no more than the number of bedrooms. These boxes must be served by a dimmer, vacancy sensor control, low voltaae wiring, orfan speed control. Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust § 150.0(k)1 F: hoods) must meet the applicable reouirements of& 150.0(k). • 5/6/22 ' 2022 Single-Family Residential Mandatory Requirements Summary § 150.0(k)1G: Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JAB. • Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JAB § 150.0(k)1H: elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. § 150.0(k)1I: Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no more than 150 lumens, and are equipped with controls that automatically turn the lighting off when the drawer, cabinet or linen closet is closed. § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL ?A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be controlled separately from liahlina svstems. • § 150.0(k)2A: Accessible Controls. Lighting must have readily accessible wall-mounted controls that allow the lighting to be manually turned on and off.* § 150.0(k)2B: Multiple Controls. Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the dimmer or sensor is installed to comolv with & 150.0(kl. § 150.0(k)2C: Mandatory Requirements. Lighting controls must comply with the applicable requirements of§ 110.9. Energy Management Control Systems. An energy management control system (EMCS) may be used to comply with dimming, § 150.0(k)2D: occupancy, and control requirements if it provides the functionality of the specified control per § 110.9 and the physical controls specified in & 150.0(kl2A. Automatic Shutoff Controls. In bathrooms, garages, laundry rooms, utility rooms and walk-in closets, at least one installed luminaire § 150.0(k)2E: must be controlled by an occupancy or vacancy sensor providing automatic-off functionality. Lighting inside drawers and cabinets with ooaaue fronts or doors must have controls that turn the liaht off when the drawer or door is closed. § 150.0(k)2F: Dimmers. Lighting in habitable spaces (e.g., living rooms, dining rooms, kitchens, and bedrooms) must have readily accessible wall- mounted dimming controls that allow the lighting to be manually adjusted up and down. Forward phase cut dimmers controlling LED light sources in these spaces must comply with NEMA SSL 7 A. § 150.0(k)2K: Independent controls. Integrated lighting of exhaust fans shall be controlled independently from the fans. Lighting under cabinets or shelves, liahlina in display cabinets, and switched outlets must be controlled separately from ceilina-installed liahtina. § 150.0(k)3A: Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other buildings on the same lot, must have a manual on/off switch and either a photocell and motion sensor or automatic lime switch control) or an astronomical lime clock. An energy management control system that provides the specified control functionality and meets all applicable requirements may be used to meet these requirements. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must either comply with§ 140.8 or consume no more than 5 watts of power. § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Solar Readiness· Single-family Residences. Single-family residences located in subdivisions with 10 or more single-family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which do not have a photovoltaic system installed, must comolv with the requirements of & 110.10(b)-(e). Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 §110.10(b)1 A: square feet each for buildings with roof areas greater than 10,000 square feet. For single-family residences, the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. • § 110.1 O(b)2: Azimuth. All sections of the solar zone located on steep-sloped roofs must have an azimuth between 90-300° of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment. • Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: horizontal distance of the height difference ?etween the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as a solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a § 110.10(c): pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single-family residences and central water-heating systems a oathwav reserved for routing plumbing from the solar zone to the water-heating system. § 110.1 O(d): Documentation. A copy of the construction documents or a comparable document indicating the information from§ 110.10(b)-(c) must be provided to the occupant. § 110.10(e)1 : Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. § 110.10(e)2: Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit breaker for a future solar electric installation. The reserved space must be permanently marked as "For Future Solar Electric." Electric and Energy Storage Ready: 5/6/22 § 150.0(s) § 150.0(t) § 150.0(u) § 150.0(v) 2022 SingleaFamiiy Residential Mandatory Requirements Summary Energy Storage System (ESS) Ready. All single-family residences must meet all of the following: Either ESS-ready interconnection equipment with backed up capacity of 60 amps or more and four or more ESS supplied branch circuits, Q[ a dedicated raceway from the main service to a subpanel that supplies the branch circuits in § 150.0(s); at least four branch circuits must be identified and have their source collocated at a single panelboard suitable to be supplied by the ESS, with one circuit supplying the refrigerator, one lighting circuit near the primary exit, and one circuit supplying a sleeping room receptacle outlet; main panelboard must have a minimum busbar rating of 225 amps; sufficient space must be reserved to allow future installation of a system isolation equipment/transfer switch within 3' of the main anelboard, with racewa s installed between the anelboard and the switch location to allow the connection of backu ower source. Heat Pump Space Heater Ready. Systems using gas or propane furnaces to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3' of the furnace with circuit conductors rated at least 30 amps with the blank cover identified as "240V ready;" and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker ermanentl marked as "For Future 240V use." Electric Cooktop Ready. Systems using gas or propane cooktop to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3' of the cooktop with circuit conductors rated at least 50 amps with the blank cover identified as "240V ready;" and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as "For Future 240V use." Electric Clothes Dryer Ready. Clothes dryer locations with gas or propane plumbing to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3' of the dryer location with circuit conductors rated at least 30 amps with the blank cover identified as "240V ready;" and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker ermanentl marked as "For Future 240V use." *Exceptions may apply. 5/6/22 HVAC SYSTEM HEATING AND COOLIN G LOADS SUMMARY Project Name 1276 Pine Ave ADU System Name hvac ENGINEERING CHECKS SYSTEM LOAD Date 1/12/2023 Floor Area 1,078 Number of Systems COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per Svstem 35,000 Total Room Loads 952 19,289 677 337 13,034 Total Output (Btuh) 35,000 Return Vented Lighting 0 Output (Btuh/saftl 32.5 Return Air Ducts 708 640 Cooling System Return Fan 0 0 Output per Svstem 24,000 Ventilation 0 0 0 0 0 Total Cutout (Btuhl 24,000 Supply Fan 0 0 Total Output (Tons) 2.0 Supply Air Ducts 708 640 Total Output (Btuh/saftl 22.3 Total Output (saft/Tonl 539.0 TOTAL SYSTEM LOAD 20,705 677 14,314 Air Svstem CFM per System O HVAC EQUIPMENT SELECTION Airflow (cfml O existing Carrier 58TN0A045C 21,949 1,528 35,000 Airflow (cfm/saftl 0.00 Airflow (cfm/Ton) 0.0 1---..:..o_uts'--id_e_A_ir_,l_¾"--l ___ +-__ o_.o--1% Total Adjusted System Output Outside Air (cfm/saftl 0.00 (Adjusted for Peak Design conditions) 21,949 1,528 35,000 Note: values above aiven at ARI conditions TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 34 °F 67 °F 105 °F ~.,_____~____.-el __ ____... rr 1-~1 l !Fl _ ___, Outside Air la) j;f llcl 1 -o-• 0 cfm Heating Coil 104 °F • I f ROOM t , 68°F ~ ______ ____.I COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 83 / 67 °F 76 I 62 °F 55 / 54 °F . ~ ~ ► ~-.. ] •• 1 ··-, A Ou-t-sid_e_A•i"""r..,_ ~----~--------..~ 1 ~1------------+ 11::J O cfm Cooling Coil i 56 I 54 °F 46.6% r ROOM 6 tJ : 76 / 62 °F 75 / 62 °F .__ .. ....,......__ --4------....--r r -~r ·T-~---------~'