Loading...
HomeMy WebLinkAbout2657 IXIA WAY; ; CBRA2023-0194; PermitBuilding Permit Finaled (cityof Carlsbad Residential Associated Permit Print Date: 09/17/2024 Job Address: 2657 IXIA WAY, CARLSBAD, CA 92008-3748 Permit Type: BLDG-Associated Permit Residential Work Class: Parcel #: 2071013500 Track#: Valuation: $341,184.99 Lot ti: Occupancy Group: R3/U Project#: #of Dwelling Units: 1 Plan #: Condo CT 16-07 DEV16038 Bedrooms: 3 Construction Type:V-B Bathrooms: Orig, Plan Check#: PC2022-0005 Occupant Load: O Plan Check#: PC2023-0036 Code Edition: 2019 Sprinkled: Yes Project Title: MARJA ACRES Permit No: Status: CBRA2023-0194 Closed -Fi na led Applied: 10/19/2023 Issued: 12/06/2023 Fina led Close Out: 09/17/2024 Fi nal Inspection: 08/07/2024 INSPECTOR: Renfro, Chris Consultant, Landscape Description: MARJA ACRES: (CORAL RIDGE) PHASE Fl// BLDG FlO // UNIT 86S // 1688 SF LIV// 493 SF GARAGE Applicant: KB HOME COASTAL INC ELI ZABETH SHOEMAKER 9915 MIRA MESA BLVD, # 100 SAN DIEGO, CA 92131-7001 FEE ATTACHED ACCESSO RY & UTILITY USES DUP FLRPLN SFD & DUPLEXES PARK IN-LI EU ATTACHED (4 UNITS OR LESS) NW PUBLIC FACILITIES FEES -outside CFD SB1473 -GREEN BUILDING STATE STANDARDS FEE STRONG MOTION -RESIDENTIAL (SM IP) Total Fees: $20,659.49 Total Payments To Date: Building Division $20,659.49 Contractor: KB HOME COASTAL INC 9915 MIRA MESA BLVD, # STE 100 SAN DIEGO, CA 92131-7001 (951) 691-5300 Ba lance Due: AMOUNT $943.03 $1,302.64 $6,414.00 $11,941.47 $14.00 $44.35 $0.00 Page 1 of 1 1635 Faraday Av enue, Carlsbad CA 92008-73 14 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov Building Permit Inspection History Finaled {city of Carlsbad Permit Type: Work Class: Status: Scheduled Date 01/03/2024 01 /16/2024 PERMIT INSPECTION HISTORY for (CBRA2023-0194) BLDG-Associated Permit Residenti, Application Date: 10/19/2023 Owner: Condo Issue Date: 12/06/2023 Subdivision: RANCHO AGUA HEDIONDA POR OF Closed -Finaled Expiration Date: 12/09/2024 Address: 2657 IXIA WAY IVR Number: 52682 CARLSBAD, CA 92008-3748 Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Start Date 07/31 /2024 BLDG-Planning Final 256761 -2024 Status Passed Landscape Consultant Checklist Item COMMENTS BLDG-Building Deficiency NOTES Created By Paula Cross TEXT PROJECT: Marja Acres (On-Site Residential) Project Numbers: LPC2021-0008, CT16-07, DWG 529-9M The following Units for Bldg. F10 have satisfactorily completed the associated landscape installation and may be released for Permanent Occupancy. The Permit Cards for each Unit were not available on site for signature. Coral Ridge -Bldg. F10 • Unit 85S - 2687 lxia Way -CBRA2023-0195 Coral Ridge -Bldg. F10 • Unit 86S - 26 7 lxia Way -CBRA2023-0194 Coral Ridge -Bldg. F10 • Unit 87S - 2619 lxia Way -CBRA2023-0193 Coral Ridge Building M2, Phase 24 has been designated as the final Building and Units for lhe Coral Ridge half of lhe project. No Units from this Building (M2) will be released until all landscape punch list items and close out documents have been completed and approved for all phases of Coral Ridge. 01/03/2024 BLDG-21 235439-2024 Passed Chris Renfro Underground/Underflo or Plumbing Checklist Item BLDG-Building Deficiency COMMENTS 01/16/2024 BLDG-11 236671 -2024 Foundation/Ftg/Piers (Rebar) Checklist Item BLDG-Building Deficiency COMMENTS Passed Chris Renfro Passed No Created Date 08/01 /2024 Passed Yes Passed Yes Complete Complete Complete Tuesday, September 17, 2024 Page 1 of 8 PERMIT INSPECTION HISTORY for (CBRA2023-0194) Permit Type: BLDG-Associated Permit Residenti, Application Date: 10/19/2023 Owner: Work Class: Condo Issue Date: 12/06/2023 Subdivision: RANCHO AGUA HEDIONDA POR OF Status: Closed -Finaled Expiration Date: 12/09/2024 Address: 2657 IXIA WAY IVR Number: 52682 CARLSBAD, CA 92008-3748 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection Date Start Date Status BLDG-SW-Inspection 236766-2024 Passed Chris Renfro Complete Tuesday, September 17, 2024 Page 2 of 8 PERMIT INSPECTION HISTORY for (CBRA2023-0194) Permit Type: Work Class: Status: Scheduled Date BLDG-Associated Permit Residenti; Application Date: Condo Issue Date: Closed -Finaled Expiration Date: IVR Number: Actual Inspection Type Start Date Inspection No. Checklist Item Are inactives slopes properly sta bilized? Are areas flatter than 3:1 covered or protected? Are sediment control s properly maintained? Are erosion control BMPs functioning properly? Are natural areas protected from erosion? Do basins appear to be maintained as required? Are perimeter control BMPs maintained? Is the entrance stabilized to prevent tracking? Have sediments been tracked on to the street? Are storm drain inlets protected and maintained? Have materials collected around the storm drains? Has sediment accumulated on impervious surfaces? Are dumpsters and trash receptacles covered? Has trash/debris accumulated throughout the site? Are stockpiles and spoils protected from runoff? Are all storage areas clean and maintained? Are spill kits provided onsite? Are washout areas maintained and protected? Were spills/leaks observed during the inspection? Were there any discharges during the inspection? Is the SWPPP wall map up to date and accurate? Was the SWPPP or Erosion Control Plan reviewed? Are portable restrooms properly positioned? Do portable restrooms have secondary containment? Are BMPs stockpiled for emergency deployment? COMMENTS Tuesday, September 17, 2024 10/19/2023 12/06/2023 12/09/2024 52682 Inspection Status Owner: Subdivision: RANCHO AGUA HEDIONDA POR OF Address: 2657 IXIA WAY CARLSBAD, CA 92008-3748 Primary Inspector Reinspection Inspection Passed Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Page 3 of8 I PERMIT INSPECTION HISTORY for (CBRA2023-0194) Permit Type: BLDG-Associated Permit Residenti; Application Date: 10/19/2023 Owner: Work Class: Condo Issue Date: 12/06/2023 Subdivision: RANCHO AGUA HEDIONDA POR OF Status: Closed -Finaled Expiration Date: 12/09/2024 Address: 2657 IXIA WAY IVR Number: 52682 CARLSBAD, CA 92008-3748 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 04/02/2024 04/02/2024 BLDG-14 243910-2024 Partial Pass Chris Renfro Reinspection Incomplete Frame/Steel/Bolting/VVe !ding (Decks) Checklist Item COMMENTS Passed BLDG-Building Dericiency 2nd story deck nailing Yes BLDG-SW-Inspection 244123-2024 Partial Pass Chris Renfro Reinspection Incomplete Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 04/15/2024 04/15/2024 BLDG-14 245094-2024 Partial Pass Chris Renfro Relnspectlon Incomplete Frame/Steel/Bolting/VVe lding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency 3rd story deck nailing Yes B LDG-SW-1 ns pection 245240-2024 Partial Pass Chris Renfro Reinspection Incomplete Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? Tuesday, September 17, 2024 Page 4 of 8 I PERMIT INSPECTION HISTORY for (CBRA2023-0194) Permit Type: BLDG-Associated Permit Residenti: Application Date: 10/19/2023 Owner: Work Class: Condo Issue Date: 12/06/2023 Subdivision: RANCHO AGUA HEDIONDA POR OF Status: Closed -Finaled Expiration Date: 12/09/2024 Address: 2657 IXIA WAY IVR Number: 52682 CARLSBAD, CA 92008-3748 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 05/02/2024 05/02/2024 BLDG-15 Roof/ReRoof 24 7152-2024 Passed Chris Renfro Complete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-SW-Inspection 247267-2024 Partial Pass Chris Renfro Reinspect ion Incomplete Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 05/14/2024 05/14/2024 BLDG-13 Shear 248263-2024 Failed Chris Renfro Reinspection Incomplete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 05/16/2024 05/16/2024 BLDG-13 Shear 248631-2024 Passed Chris Renfro Complete PanelsfHD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-SW-Inspection 248765-2024 Partial Pass Chris Renfro Reinspection Incomplete Tuesday, September 17, 2024 Page 5 of 8 PERMIT INSPECTION HISTORY for (CBRA2023-0194) Permit Type: BLDG-Associated Permit Residenti: Application Date: 10/19/2023 Owner: Work Class: Condo Issue Date: 12/06/2023 Subdivision: RANCHO AGUA HEDIONDA POR OF Status: Closed -Finaled Expiration Date: 12/09/2024 Address: 2657 IXIA WAY IVR Number: 52682 CARLSBAD, CA 92008-3748 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is t11e entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 06/03/2024 06/03/2024 BLDG-84 Rough 250359-2024 Passed Chris Renfro Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers BLDG-SW-Inspection 250510-2024 Partial Pass Chris Renfro Reinspection Incomplete Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 06/07/2024 06/07/2024 BLDG-16 Insulation 251066-2024 Passed Chris Renfro Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes Tuesday, September 17, 2024 Page 6 of 8 PERMIT INSPECTION HISTORY for (CBRA2023-0194) Permit Type: BLDG-Associated Permit Residenti: Application Date: 10/19/2023 Owner: Work Class: Condo Issue Date: 12/06/2023 Subdivision: RANCHO AGUA HEDIONDA POR OF Status: Closed -Finaled Expiration Date: 12/09/2024 Address: 2657 IXIA WAY IVR Number: 52682 CARLSBAD, CA 92008-3748 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection Date Start Date Status BLDG-SW-Inspection 251132-2024 Partial Pass Chris Renfro Reinspection Incomplete Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 06/11/2024 06/11 /2024 BLDG-18 Exterior 251330-2024 Passed Chris Renfro Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes B LDG-SW-f nspectl on 251462-2024 Partial Pass Chris Renfro Re inspection Incomplete Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 07115/2024 07/15/2024 BLDG-Electric Meter 254728-2024 Partial Pass Chris Renfro Reinspection Incomplete Release Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-SW-Inspection 254814-2024 Partial Pass Chris Renfro Reinspection Incomplete Tuesday, September 17, 2024 Page 7 of 8 PERMIT INSPECTION HISTORY for (CBRA2O23-0194) Permit Type: BLDG-Associated Permit Residenti; Work Class: Condo Application Date: 10/19/2023 Issue Date: 12/06/2023 Status: Scheduled Date 08/07/2024 Closed -Finaled Expiration Date: 12/09/2024 IVR Number: 52682 Actual Inspection Type Start Date Inspection No. Checklist Item Are erosion control BMPs functioning properly? Are perimeter control BMPs maintained? Is the entrance stabilized to prevent tracking? Have sediments been tracked on to the street? Has trash/debris accumulated throughout the site? Are portable restrooms properly positioned? Do portable restrooms have secondary containment? COMMENTS 08/07/2024 BLDG-Final Inspection Checklist Item 257202-2024 COMMENTS BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Inspection Status Passed Owner: Subdivision: RANCHO AGUA HEDIONDA POR OF Address: 2657 IXIA WAY CARLSBAD, CA 92008-3748 Primary Inspector Reinspection Inspection Chris Renfro Passed Yes Yes Yes Yes Yes Yes Yes Passed Yes Yes Yes Yes Yes Complete BLDG-SW-Inspection Checklist Item 257344-2024 COMMENTS Partial Pass Chris Renfro Reinspection Incomplete Tuesday, September 17, 2024 Are erosion control BM Ps functioning properly? Are perimeter control BMPs maintained? Is the entrance stabilized lo prevent tracking? Have sediments been tracked on to the street? Has trash/debris accumulated throughout the site? Are portable restrooms properly positioned? Do portable restrooms have secondary containment? Passed Yes Yes Yes Yes Yes Yes Yes Page 8 of 8 ,r • HEIGHT/ Development Services '--City of souNDARv Carlsbad City 0~ r.:aE.fl1itf l B-6 0 D Building Division PG.fd Faraday Avenue l 760-602-2719 www.carlsbadca.gov 8-60 SE? 0 9 iOZ4 This form shall be corrij~~/~~ijl~J!Rl~~eight and/or boundary when requested by the Building Division. CBRA2023-0193, -0194, -0195 207 Permit #: ____________ .Ass essor's Parcel Number: ___ _ 102 05 Site Address: 2619, 2657, 2687 lxia Way Owner's Name: KB Marja Acres 248 LLC Thi s is to affirm that on_4_1_2_9_f2_0_2_4 _______ (date) the structure being constructed on the site was surveyed by, or under the direction of, the undersigned. HIEGHT CERTIFICATION: iii The height from the lower of natural or finished grade to the highest finished point of the roof ridge elevation, or any part of the structure immediately above, was found to be in conformance with the approved plans. Surveyed height measurement (top of roof sheathing) at point(s) identified in approved plans as the highest point(s) of the structure above lower of natural or finished grade elevation. (Attach 8 ½"x 11" sheets showing elevation(s) of structure where measurement(s) were taken and location on site plan where they were taken) Total thickness of roofing materials (i.e. felt and roofing) to be installed after sheathing inspection, not to exceed: N/A Total Height: _3_3_.9_7_' ___ _ BOUNDARY CERTIFICATION: iii The boundary survey completed on the parcel establishes confirmation of setback compliance for the new construction proposed with this permit. The proposed setback shown on the design documents of 4o· feet from the property boundary to the inside edge of the foundation forms is confirmed to be in compliance with the proposed design. Applicable easements and/or encroachments discovered were brought to the attention of the property owner, project applicant and/or designer for design consideration. Land records research and/or a field survey was completed to determine this compliance. Seal of Registration Registered Civil Engineer, Structural Engineer, or Licensed Land Surveyor NOTE: Property owner or project applicant/developer may not certify building height. Planning Division Acknowledgement: _______________ Date:. _____ _ PROJECT PLANNER Page 1 of 1 Rev. 10/21 ,.,,~ ~' it-I/< {P'7 ' ~,,., ?, """-°"7;"-. ""----~ ~-... .,--~ --~ -......--J ...... ,~ ____ ! .. --..,_e--.. -,-_ -~ ... ~ BUILDING HEIGH CERT. EXHIBT CORAL RIDGE BLDG F-10 UNITS 85-87 ALLOWABLE HT.= 35' MAX. SURVEY= 33.97' MAY 3, 2024