HomeMy WebLinkAboutDWG 540-7B; SDP 2021-0029; IONIS CONFERENCE CENTER; 01-13NFNF GRADING NOTES (IN ADDITION TO THE REQUIREMENTS OF CHAPTER 15.16 OF THE CARLSBAD MUNICIPAL CODE.) 1. THIS PLAN SUPERSEDES ALL OTHER PLANS PREVIOUSLY APPROVED BY THE CITY OF CARLSBAD REGARDING GRADING SHOWN ON THIS SET OF PLANS. 2. APPROVAL OF THIS PLAN DOES NOT LESSEN OR WAIVE ANY PORTION OF THE CARLSBAD MUNICIPAL CODE, RESOLUTION OF CONDITIONAL APPROVAL, CITY STANDARDS OR OTHER ADDITIONAL DOCUMENTS LISTED HEREON AS THEY MAY PERTAIN TO THIS PROJECT. THE ENGINEER IN RESPONSIBLE CHARGE SHALL REVISE THESE PLANS WHEN NON-CONFORMANCE IS DISCOVERED. 3. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER OR ENGINEER OF WORK FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. ALL PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL. 4. A RIGHT-OF-WAY PERMIT FROM THE CITY ENGINEER WILL BE REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY. PRIOR TO PERMIT ISSUANCE, A CERT/FICA TE OF INSURANCE AS WELL AS ADDITIONAL INSURED ENDORSEMENT MUST BE FILED NAMING THE CITY OF CARLSBAD AS AN ADDITIONAL INSURED ON THE PERMfTTEE'S POLICY IN THE MINIMUM AMOUNT OF $1,000,000.00 FOR EACH OCCURRENCE OF LIABILITY THE INSURANCE COMPANY WRITING THE POLICY MUST HA VE A RA TING OF 'A-' OR BETTER AND A SIZE CA TE GORY OF CLASS Vff OR BETTER AS ESTABLISHED BY "BESTS" KEY RA TING GUIDE. 5. NO WORK SHALL BE COMMENCED UNTIL ALL PERMITS HAVE BEEN OBTAINED FROM THE CITY AND OTHER APPROPRfA TE AGENCIES. 6. APPROVAL OF THESE PLANS BY THE CITY ENGINEER DOES NOT AUTHORIZE ANY WORK OR GRADING TO BE PERFORMED UNTIL THE PROPERTY OWNER'S PERMISSION HAS BEEN OBTAINED AND A VALID GRADING PERMIT HAS BEEN ISSUED. 7. REVISION OF THESE PLANS MAY BE REQUIRED IF THE PROPOSED IMPROVEMENTS ARE NOT CONSTRUCTED PRIOR TO THE DEADLINE DATE OF THE IMPROVEMENT AGREEMENT. 8. NO REVISIONS WILL BE MADE TO THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE CITY ENGINEER, NOTED WITHIN THE REVISION BLOCK, ON THE APPROPRIATE SHEET OF THE PLANS AND THE TITLE SHEET. 9. ORIGINAL DRAWINGS SHALL BECOME THE PROPERTY OF THE CITY UPON BEING SIGNED BY THE CITY ENGINEER. 10. THE ORIGINAL ORA WING SHALL BE REVISED TO REFLECT AS.BUILT CONDITIONS BY THE ENGINEER-OF-WORK PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY. 11. ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT SITE AT ALL TIMES DURING CONSTRUCTION. 12. WHERE TRENCHES ARE WITHIN CITY EASEMENTS, A SOILS REPORT COMPRISED OF: (A) SUMMARY SHEET, (B) LABORATORY WORK SHEETS AND (C) COMPACTION CURVES, SHALL BE SUBMITTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. THE SOILS REPORT WILL BE SUBMITTED TO THE CITY ENGINEERING INSPECTOR WITHIN TWO WORK/NG DAYS OF THE COMPLETION OF FIELD TESTS. 13. A SOILS COMPACTION REPORT AND COMPLIANCE VER/FICA TION REGARDING ADHERENCE TO RECOMMENDA T/ONS OUTLINED IN THE SOILS REPORT IS REQUIRED PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL CONTROLLED GRADING SHALL BE DONE UNDER THE DIRECTION OF A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. ALL FILL OR FUTURE FILL AREAS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF CARLSBAD STANDARD SPECIFICATIONS AND THE "EARTHWORK SPECIFICATIONS" ATTACHED TO THE PRELIMINARY SOILS INVEST/GA TION. DAILY FIELD COMPACTION REPORTS WILL BE SUBMITTED TO THE PROJECT INSPECTOR. 14. A PRE-CONSTRUCTION MEETING SHALL BE HELD AT THE SITE PRIOR TO THE BEGINNING OF WORK AND SHALL BE ATTENDED BY ALL REPRESENTATIVES RESPONSIBLE FOR CONSTRUCTION, INSPECTION, SUPERVISION, TESTING AND ALL OTHER ASPECTS OF THE WORK THE CONTRACTOR SHALL REQUEST A PRE-CONSTRUCTION MEETING BY CALLING THE INSPECTION LINE AT (760) 438-3891 AT LEAST FIVE(5) WORKING DAYS PRIOR TO STARTING CONSTRUCTION. THE CONTRACTOR WILL THEN BE CONTACTED BY THE PROJECT INSPECTOR TO COORDINATE A DA TE AND TIME FOR THE PRE-CONSTRUCTION MEETING. APPROVED DRAWINGS MUST BE AVAILABLE PRIOR TO SCHEDULING. THE GRADING PERMIT WILL BE PROVIDED BY THE PROJECT INSPECTOR AT THE MEETING. 15. ALL INSPECTION REQUESTS OTHER THAN FOR PRE-CONSTRUCTION MEETING WILL BE MADE BY CALLING THE ENGINEERING 24-HOUR INSPECTION REQUEST LINE AT /760) 438-3891. INSPECTfON REQUEST MUST BE RECEIVED PRIOR TO 2:00 P.M. ON THE DAY BEFORE THE INSPECTION IS NEEDED. INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE. REQUESTS MADE AFTER 2:00 P.M. WILL BE SCHEDULED FOR TWO FULL WORKDAYS LATER. 16. THE OWNER AND/OR APPLICANT THROUGH THE DEVELOPER AND/OR CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 17. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMITTING A DETAIL PLAN TO THE CITY ENGINEER AND/OR CONCERNED AGENCY SHOWING THE DESIGN OF SHORING, BRACING SLOPING OR OTHER PROVISIONS TO BE MADE OF WORKER PROTECTION FROM THE HAZARD OF CAVING GROUND DURING THE EXCAVATION OF SUCH TRENCH OR TRENCHES OR DURING THE PIPE INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (57 OR MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER AND/OR CONCERNED AGENCY PRIOR TO EXCAVATION. IF THE PLAN VARIES FROM THE SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS, TITLE 8 CALIFORNIA AOMfNISTRA TIVE CODE. THE PLAN SHALL BE PREPARED BY A REGISTERED ENGINEER AT THE CONTRACTORS EXPENSE. A COPY OF THE OSHA EXCAVATION PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO EXCAVATION. 18. NO BLASTING SHALL BE PER.FOR.MED UNTIL A VALID BLASTING PERMIT HAS BEEN OBTAINED FROM THE CITY OF CARLSBAD. SUBMIT APPLICATION FOR BLASTING PERMIT WELL IN ADVANCE OF THE SCHEDULING OF BLASTING OPERATIONS. 19. IF ANY ARCHAEOLOGICAL RESOURCES ARE DISCOVERED WITHIN ANY WORK AREA DURING CONSTRUCTION, OPERATIONS WILL CEASE fMMEOfA TEL Y. AND THE PERMfTTEE WILL NOTIFY THE CITY ENGINEER. OPERATIONS WILL NOT RESTART UNTIL THE PERMITTEE HAS RECEIVED WRITTEN AUTHORITY FROM THE CITY ENGINEER TO DO SO. 20. ALL OPERA T/ONS CONDUCTED ON THE SITE OR ADJACENT THERETO, INCLUDING WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR OPERA TfON OF TRUCKS, EARTHMOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOC/A TED GRADING EQUIPMENT SHALL BE LIMITED TO THE PERIOD BETWEEN 7:00 A.M. AND 6:00 P.M. EACH DAY, MONDAY THRU FRIDAY AND NO EARTHMOVING OR GRADING OPERATIONS SHALL BE CONDUCTED ON WEEKENDS OR HOLIDAYS. (A LIST OF CITY HOLIDAYS IS AVAILABLE AT THE ENGINEERING DEPARTMENT COUNTER.) 21. ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY ENGINEER FOR APPROVAL TWO FULL WORK/NG DAYS PRIOR TO BEGINNING OF WORK. 22. IMPORT MATERIAL SHALL BE OBTAINED FROM, AND WASTE MA TE RIAL SHALL BE DEPOSITED AT, A SITE APPROVED BY THE CITY ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTES OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION. 23. BRUSH SHALL BE REMOVED ONLY WITHIN THE AREA TO BE GRADED. NO TREES ARE TO BE REMOVED UNLESS SPECIFICALLY NOTED ON THE PLAN. 24. ALL AREAS SHALL BE GRADED TO DRAIN. GRADING RESULTING IN THE PONDING OF WATER IS NOT PERMITTED. ALL EARTHEN SWALES AND DITCHES SHALL HAVE A MINIMUM ONE PERCENT SLOPE. 25. THESE PLANS ARE SUBJECT TO A SIGNED AND APPROVED SWPPP AND/OR SET OF EROSION CONTROL PLANS. EROSION CONTROL SHALL BE AS SHOWN AND AS APPROVED BY THE CITY ENGINEER OR AS DIRECTED BY THE PROJECT INSPECTOR. 26. ALL SLOPES SHALL BE TRIMMED TO A FINISH GRADE TO PRODUCE A UNIFORM SURFACE AND CROSS SECTION. THE SITE SHALL BE LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS OR OTHER DEBRIS SHALL BE REMOVED AND DISPOSED OF AT A SITE APPROVED OF BY THE CITY ENGINEER. 27. ALL SLOPES SHALL BE IRRIGATED, STABILIZED, PLANTED AND/OR HYDROSEEDED WITHIN TEN (10) DAYS OF THE TIME WHEN EACH SLOPE IS BROUGHT TO GRADE AS SHOWN ON THE APPROVED GRADING PLANS. 28. LANDSCAPING SHALL BE ACCOMPLISHED ON ALL SLOPES AND PADS AS REQUIRED BY THE CITY OF CARLSBAD LANDSCAPE MANUAL, THE LANDSCAPING PLANS FOR THIS PROJECT, ORA WING NO. XXX-XX. AND/OR AS DIRECTED BY THE CITY ENGINEER OR PLANNING DIRECTOR. 29. THE OWNER/APPLICANT SHALL INSURE THAT ALL CONTRACTORS SHALL COORDINATE THE WORK OF THESE GRADING PLANS WITH THAT SHOWN ON BOTH THE LANDSCAPE AND IRRIGATION PLANS AND THE IMPROVEMENT PLANS AS REQUIRED FOR THIS WORK IN ACCORDANCE WITH THE LANDSCAPE MANUAL TIME REQUIREMENTS. 30. WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED AS A RESULT OF THE GRADING OPERA TfON, fT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SO/LS. IN OTHER AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER. 31. THE EXISTENCE AND LOCATION OF UTILITY STRUCTURES AND FACILITIES SHOWN ON THE CONSTRUCTION PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. ATTENTION IS CALLED TO THE POSSIBLE EXISTENCE OF OTHER UTILITY FACILITIES OR STRUCTURES NOT SHOWN OR IN A LOCATION DIFFERENT FROM THAT SHOWN ON THE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN ON THE PLANS AND ANY OTHER EXISTING FACILITIES OR STRUCTURES NOT SHOWN. 32. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING FACILITIES (ABOVE GROUND AND UNDER GROUND) WITHIN THE PROJECT SITE SUFFfCfENTL Y AHEAD OF GRADING TO PERMIT THE REVISION OF THE GRADING PLANS IF fT IS FOUND THAT THE ACTUAL LOCA T/ONS ARE IN CONFLICT WITH THE PROPOSED WORK 33. THE CONTRACTOR SHALL NOTIFY AFFECTED UTILITY COMPANIES (SEE BELOW) AT LEAST 2 FULL WORKING DAYS PRIOR TO STARTING GRADING NEAR THEIR FACILITIES AND SHALL COORDINATE THE WORK WITH A COMPANY REPRESENTATIVE. UNDERGROUND SERVICE ALERT (DIG ALERT) SDG&E AT&T SPECTRUM CABLE COX COMMUN/CATIONS CITY OF CARLSBAD(STREETS & STORM DRAIN) 'CITY OF CARLSBAD(SEWER, WATER & RECLAIMED WATER) 'SAN DIEGUITO WATER DISTRICT 'LEUCADIA WASTEWATER DISTRICT 'VALLECfTOS WATER DISTRICT 'OLIVENHAfN WATER DISTRICT 'BUENA SANfTA TION DISTRICT 'AS APPROPRfA TE 34. PERMIT COMPLIANCE REQUIREMENTS: 811 (800)411-7343 (619)237-2787 (800)227-2600 (619)262-1122 (760)434-2980 (760)438-2722 (760)633-2650 (760)753-0155 (760)744-0460 (760)753-6466 (760)726-1340 x1330 A. FOR CONTROLLED GRADING -THE APPLICANT HIRES A CIVIL ENGINEER, SOILS ENGINEER, AND/OR GEOLOGIST TO GIVE TECHNICAL ADVICE, OBSERVE AND CONTROL THE WORK IN PROGRESS (15.16.120 A.BJ CARLSBAD MUNICIPAL CODE. B. PRIOR TO COMPLETION OF GRADING WORK -THE FOLLOWING REPORTS MUST BE SUBMITTED TO THE CITY ENGINEER VIA THE PROJECT INSPECTOR PER SECTION 15.16.120 OF THE CARLSBAD MUN/Cf PAL CODE: (1) FINAL REPORT BY SUPERVISING GRADING ENGINEER STATING ALL GRADING IS COMPLETE. ALL EROSION CONTROL, SLOPE PLANTING AND IRRIGATION ARE INSTALLED IN CONFORMANCE WITH CITY CODE AND THE APPROVED PLANS (OBTAIN SAMPLE OF COMPLIANCE LETTER FROM CITY ENGINEER/NG DEPARTMENT). (2) AS-BUILT GRADING PLAN. (3) REPORT FROM THE SOILS ENGINEER, WHICH INCLUDES RECOMMENDED SOIL BEARING CAPACITIES, A STATEMENT AS TO THE EXPANSIVE QUALITY OF THE SOIL, AND SUMMARIES OF FIELD AND LAB ORA TORY TESTS. THE REPORT SHALL ALSO INCLUDE A STATEMENT BY THE SOILS ENGINEER THAT THE GRADING WAS DONE IN ACCORDANCE WITH THE REQUIREMENTS AND RECOMMENDA T/ONS OUTLINED IN THE PRELIMINARY SOILS REPORT AND ANY SUPPLEMENTS THERETO. (4) REPORT WITH AS-BUILT GEOLOGIC PLAN, IF REQUIRED BY THE CITY. 35. UNLESS A GRADING PERMIT FOR THIS PROJECT IS ISSUED WITHIN ONE (1) YEAR AFTER THE CITY ENGINEER'S APPROVAL, THESE PLANS MAY BE REQUIRED TO BE RESUBMITTED FOR PLANCHECK. PLANCHECK FEES WILL BE REQUIRED FOR ANY SUCH RECHECK. 36. IN ACCORDANCE WITH THE CITY STORM WATER STANDARDS, ALL STORM DRAIN INLETS CONSTRUCTED BY THIS PLAN SHALL INCLUDE "STENCILS" BE ADDED TO PROHIBIT WASTEWATER DISCHARGE DOWNSTREAM. STENCILS SHALL BE ADDED TO THE SA TfSFACTfON OF THE CITY ENGINEER. TEMPORARY EROSION CONTROL PLANTING AND /RR/GA TION ALL PERMANENT AND TEMPORARY EROSION CONTROL PLANTING AND IRRIGATION SHALL BE INSTALLED AND MAINTAINED AS REQUIRED IN SECTION 212 OF THE STANDARD SPECIF/CATIONS AND THE FOLLOWING: A. HYDROSEEDING SHALL BE APPLIED TO: 1. ALL SLOPES THAT ARE GRADED 6:1 (HORIZONTAL TO VERTICAL) OR STEEPER WHEN THEY ARE: a. THREE FEET OR MORE IN HEIGHT AND ADJACENT TO A PUBLIC WALL OR STREET. b. ALL SLOPES 4 FEET OR MORE IN HEIGHT. 2. AREAS GRADED FLATTER THAN 6:1 WHEN ANY OF THE FOLLOWING CONDITIONS EXIST a. NOT SCHEDULED FOR IMPROVEMENTS (CONSTRUCTION OR GENERAL LANDSCAPING) WITHIN 60 DAYS OF ROUGH GRADING. b. IDENTIFIED BY THE PARKS AND RECREATION DIRECTOR AS HIGHLY VISIBLE TO THE PUBLIC. c. HAVE ANY SPECIAL CONDITION IDENTIFIED BY THE CITY ENGINEER THAT WARRANTS fMMEDIA TE TR.EA TMENT. B. HYDROSEEDED AREAS SHALL BE IRRIGATED IN ACCORDANCE WITH THE FOLLOWING CRITERIA 1. ALL SLOPES THATAREGRADED6:1 OR STEEPER AND THAT ARE: a. THREE TO EIGHT FEET IN HEIGHT SHALL BE IRRIGATED BY HAND WA TERfNG FROM QUICK COUPLERS/HOSE BIBS OR A CONVENTIONAL SYSTEM OF LOW PRECIPITATION SPRINKLER HEADS PROVIDING 100% COVERAGE. b. GR.EATER THAN 8 FEET IN HEIGHT SHALL BE WATERED BY A CONVENTIONAL SYSTEM OF LOW PRECIPITATION SPRINKLER HEADS PROVIDING 100% COVERAGE. 2. AREAS SLOPED LESS THAN 6:1 SHALL BE IRRfGA TED AS APPROVED BY THE CITY ENGINEER, PRIOR TO HYDROSEEDING. THE DEVELOPER SHALL SUBMIT A PROPOSED SCHEME TO PROVIDE fRRIGA TfON TO THE CITY ENGINEER. THE PROPOSAL SHALL BE SPECIFIC REGARDING THE NUMBERS, TYPES AND COSTS OF THE ELEMENTS OF THE PROPOSED SYSTEM. 3. IRRfGA TION SHALL MAINTAIN THE MOISTURE LEVEL OF THE SOIL AT THE OPTIMUM LEVEL FOR THE GROWTH OF THE HYDROSEEDED GROWTH C. HYDROSEEDfNG MIX SHALL CONSIST OF ALL OF THE FOLLOWING: 1. SEED MIX SHALL CONSIST OF NO LESS THAN: a. 20 lbs. PER ACRE OF ROSE CLOVER b. 20 lbs. PER ACRE OF ZORRO FESCUE c. 3 lbs. PER ACRE OF E SCHOOL CIA CALfFORNfCA d. 4 lbs. PER ACRE OF ACHfLLEA MfLLEFOLfA e. 3 lbs. PER ACRE OF AL YSSUM (CARPET OF SNOW) f. 112 lb. PER ACRE OF DfMORPHOLECA g. ITEMS c,d,e, AND f OF THIS SUBSECTION MAY BE OMITTED ON LOCATIONS WHERE THE AREA BEING HYDROSEEDED /SNOT VISIBLE FROM EITHER A PUBLIC STREET OR RESIDENTIAL STRUCTURES. h. ITEM a OF THIS SUBSECTION MUST BE fNOCULA TED WITH A NITROGEN FIXING BACTERIA AND APPLIED DRY EITHER BY DRILLING OR BROADCASTING BEFORE HYDROSEEDfNG. i. ALL SEED MATERIALS SHALL BE TRANSPORTED TO THE JOBS/TE IN UNOPENED CONTAINERS WITH THE CALIFORNIA DEPARTMENT OF FOOD AND AGRICULTURE CERTIFICATION TAG ATTACHED TO, OR PRINTED ON SAID CONTAINERS. j. NON-PHYTO-TOXfC WETTING AGENTS MAY BE ADDED TO THE HYDROSEED SLURRY AT THE DISCRETION OF THE CONTRACTOR. 2. TYPE 1 MULCH APPLIED AT THE RA TE OF NO LESS THAN 2000 lbs PER ACRE. TYPE 6 MULCH (STRAW) MAY BE SUBSTITUTED, ALL OR PART. FOR HYDRAULICALLY APPLIED FIBER MATERIAL. WHEN STRAW IS USED fT MUST BE ANCHORED TO THE SLOPE BY MEGHAN/CALLY PUNCHING NO LESS THAN 50% OF THE STRAW INTO THE SOIL 3. FERTILIZER CONSISTING OF AMMONIUM PHOSPHATE SULFATE, 16-20-0, WITH 15% SULPHUR APPLIED AT THE RA TE OF 500 lbs. PER ACRE. D. AREAS TO BE HYDROSEEOED SHALL BE PREPARED PRIOR TO HYDROSEEDING BY: 1. ROUGHENING THE SURFACE TO BE PLANTED BY ANY OR A COMBINATION OF: a. TRACK WALK/NG SLOPES STEEPER THAN 6:1 b. HARROWING AREAS 6:1 OR FLATTER THAT ARE SUFFIC/ENTL Y FRIABLE. c. RIPPING AREAS THAT WILL NOT BREAK UP USING ITEMS a OR b ABOVE 2. CONDITIONING THE SOILS SO THAT IT IS SUITABLE FOR PLANTING BY: a. ADJUSTING THE SURFACE SOIL MOISTURE TO PROVIDE A DAMP BUT NOT SATURATED SEED BED. b. THE ADDITION OF SOIL AMENDMENTS, PH ADJUSTMENT, LEACHING COVERING SALINE SOILS TO PROVIDED VIABLE CONDITIONS FOR GROWTH. E. HYDROSEEDED AREAS SHALL BE MAINTAINED TO PROVIDE A VIGOROUS GROWTH UNTIL THE PROJECT IS PERMANENTLY LANDSCAPED OR, FOR AREAS WHERE HYDROSEEDING IS THE PERMANENT LANDSCAPING, UNTIL THE PROJECT IS COMPLETED AND ALL BONDS RELEASED. ABANDONMENT NOTES PART/ALLY COMPLETED PROJECTS SEEKING TO fNDEFfNITEL Y STOP WORK AND CLOSE THE GRADING PERMIT MUST IMPLEMENT APPROPRIATE ACCESS RESTRICTION AND EROSION AND SEDIMENT CONTROL MEASURES TO THE SATISFACTION OF THE CITY, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1) PERMANENTLY STABILIZE ALL SLOPES (>5%)-70% COVER WITH WELL-ESTABLISHED, SUSTAINABLE, NON-WEED VEGETATION (SEE CITY LANDSCAPE MANUAL FOR GUIDELINES) IS CONSIDERED ADEQUATE. 2) PERMANENTLY STABILIZE FLAT AREAS (S5%) • 70% COVER WITH WELL-ESTABLISHED, SUSTAINABLE, NON-WEED VEGETATION (SEE CITY LANDSCAPE MANUAL FOR GUIDELINES) OR 2 INCHES (MINIMUM) OF PERMEABLE COVER (E.G., GRAVEL) IS CONSIDERED ADE QUA TE. 3) RESTRICT ACCESS TO SITE -COORDINATE WITH CITY STAFF TO DETERMINE APPROPRIATE FENCING TYPE. 4) SfGNAGE ALONG FRONTAGE ROAD($) POSTING THAT DUMPING, UTTERING, AND TRESPASSING ARE PROHIBITED. 5) TRESPASS ENFORCEMENT AUTHORfZA T/ON LETTER MUST BE SENT FROM THE OWNER TO THE CITY OF CARLSBAD POLICE DEPARTMENT. 6) NOTARIZE AND RECORD AGAINST THE PROPERTY AN AGREEMENT STA TING THAT OWNER IS RESPONSIBLE FOR MAINTAINING FENCING AND SIGNAGE, ADHERING TO THE FIRE PREVENTION OR.DINA TION, KEEPING THE SITE FREE FROM LITTER ACCUMULATION AND VEGETATION GROWTH, AND REMOVING ANY fLLEGALL Y DUMPED MATERIALS AT THE SITE UNTIL THE PROPERTY IS DEVELOPED IN THE FUTURE. EROSION CONTROL NOTES 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT JIM SCATES OF BN BUILDERS AT 1858) 210-0902 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON. ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE AT CONVENIENT LOCA T/ONS TO FACfLfTA TE RAPID CONSTRUCT/ON OF TEMPORARY DEVICES WHEN RAIN IS EMINENT. 3. FOR PROJECTS COVERED BY STATE SWPPP/WDfD, IN ACCORDANCE WITH THE CONSTRUCTION ORDER ISSUED BY THE CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD, THE QUALIFIED SWPPP PRACTITIONER (QSP) SHALL UPDATE AND MAINTAIN THE WATER POLLUTION CONTROL (WPC) PLAN TO ADDRESS UPDATED SITE CONDITIONS OF THE PROJECT. THE UPDATED WPC PLAN AND UPDATED SWPPP SHALL BE KEPT AT THE PROJECT SITE AND MADE AVAILABLE TO THE CITY INSPECTOR. ADDITIONAL CONSTRUCTION BMP'S BEYOND THE ORIGINAL APPROVED SWPPP SHALL BE PROVIDED TO ADDRESS SITE CONDITIONS NOT ANTICIPATED. THE QSP SHALL REPORT BMP DEFICIENCIES TO THE CITY INSPECTOR. THE QSP SHALL OBTAIN APPROVAL FROM THE QUALIFIED SWPPP DEVELOPER AND THE CITY INSPECTOR REGARDING ANY SIGNIFICANT CHANGES TO BMP DEPLOYMENT. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATERS CREA TE A HAZARDOUS CONDITION. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED SWPPP AND/OR EROSION CONTROL PLAN SHALL BE fNCORPORA TED HEREON. 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORKING DAY 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 10. ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH 3/4 INCH MINIMUM AGGREGATE. 11. SHOULD GERM/NATION OF HYDROSEEDED SLOPES FAIL TO PROVIDE EFFECTIVE COVERAGE OF GRADED SLOPES (90% COVERAGE) PRIOR TO NOVEMBER 15, THE SLOPES SHALL BE STABILIZED BY PUNCH STRAW INSTALLED IN ACCORDANCE WITH SECTION 35.023 OF THE EROSION AND SEDIMENT CONTROL HANDBOOK OF THE DEPARTMENT OF CONSER.VAT/ON, STATE OF CALIFORNIA. "DECLARATION OF RESPONSIBLE CHARGE" I HEREBY DECLARE THAT f AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT f HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THATTHECHECKOFPROJECTDRAWINGSAND SPECIFICATIONS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. FIRM: PASCO LARET SUITER AND ASSOC/A TES, INC. ADDRESS: 119 ABERDEEN DRIVE CITY STATE: CARDIFF, CA TELEPHONE: (858) 259-8212~t), BY: _ ~ DATE: 2-9-24 GREGO W LANG, R. C.E. R.C.E. NO.: 7 REGISTRATION EXPfRA TION DA TE: 06-30-2025 SOILS ENGINEER'S CERT/FICA TE f, EMILIO ALVARADO, A REGISTERED CIVIL ENGINEER OF THE STATE OF CALIFORNIA, PRfNCfPALL Y DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS, HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE WAS MADE BY ME OR UNDER MY DIRECTION BETWEEN THE DATE OF 07 /2018 AND 03/202~ TWO COPIES OF THE SOILS REPORT COMPILED FROM THIS STUDY, WITH MY RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER. SIGNED: EMILIO ALVARADO DATE: 02-16-2024 FIRM: GEOCON, INCORPORATED 6960 FLANDERS DR SAN DIEGO, CA 92121 (858) 558-6900 R.C.E. 66915 OWNER'S CERT/FICA TE 0 ,._L\1~'2.,-....; ~v -'d ILi No. 66915 O CIVIi,,, f HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER-ALL GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY OF THIS SITE. IF THIS PROJECT! ELOPMEJIT IS SUBJ TOA STATE-REGULATED SWPPP, I ALSO AGREE A QUAUFIEDSIWPPPRAC NE )HASOEENOR LLBE AfNEDTO SUPERVf E fMPLEMENrATIDW OF THE SWPPPINA CO ANCE THE CALIFORNIA T CT DER(ND N5(AL ERMfr, LA TEST VERSION. 'O -_) .u...-- OWNER'S NAME TE Lauren Krause 6/3/2024 (PRINTED NAME} DATE SOURCE OF TOPOGRAPHY TOPOGRAPHY SHOWN ON THESE PLANS WAS GENERA TED BY AERIAL TOPOGRAPHY METHODS FROM fNFORMA TION GATHERED BY SAN-LO AERIAL SURVEY, AND SUPPLEMENTED BY FIELD TOPOGRAPHY ON MAY 26, 2018, BY PASCO LARET SUITER &ASSOCIATES, INC. TOPOGRAPHY SHOWN HEREON CONFORMS TO NATIONAL MAP ACCURACY STANDARDS. REFERENCE DRAWINGS CITY OF CARLSBAD ORA WINGS: -No. 415-9A -CARLSBAD OAKS NORTH PHASE 1 GRADING PLANS • No. 415-91 • CARLSBAD OAKS NORTH PHASE 2 GRADING PLANS -No. 415-9J -CARLSBAD OAKS NORTH PHASE 2 IMPROVEMENT PLANS -No. 415-9X -CARLSBAD OAKS NORTH PHASE 3 GRADING PLANS -No. 467-4A -IONIS PHARMACEUTICALS GRADING PLAN POTHOLE NOTE!!! CONTRACTOR TO FIELD VERIFY ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION OF PROPOSED UTILITIES PREPARED BY: VICINITY MAP CITY OF OCEANSIDE HIGHWAY 78 NOTTO SCALE PACIFIC OCEAN -SITE CITY OF ENCINITAS INDEX OF SHEETS 1 ........... TITLE SHEET 2 ........... KEY MAP & NOTES 3 .......... .PRECISE GRADING & STORM DRAIN PLAN 4 ........... SfNGLE SHEET BMP SITE PLAN 5 ........... RETA/NfNG WALL PLAN & PROFILE 6-13 ...... STRUCTURAL PLANS PROJECT ADDRESS INTERSECTION OF WHfPTAIL LOOP & GAZELLE COURT CARLSBAD, CA 92010 OWNER 2850, 2855 & 2859 GAZELLE OWNER (DE) LLC 450 PARK AVE, 9TH FLOOR NEW YORK, NY 10022 646-376-3100 LEGAL DESCRIPTION PARCEL 1 OF PARCEL MAP 21705, RECORDED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY CALIFORNIA, ON AUGUST 1, 2019 AS DOCUMENT 2019-7000285 OF OFFICIAL RECORDS. BASIS OF BEARINGS THE BASIS OF BEARINGS FOR THIS SURVEY IS THE CALIFORNIA COOR.DINA TE SYSTEM, NAO 83 (CCS83), EPOCH 1991.35, ZONE 6, AS DETERMINED LOCALLY BY A LINE BETWEEN FIRST ORDER CONTROL STATIONS CLSB-97 AND CLSB-98 BEING A GRID BEARING OF NORTH 00"30'28' WEST AS DERIVED FROM GEODETIC VALUES SHOWN ON RECORD OF SURVEY 17271, CITY OF CARLSBAD SURVEY CONTROL, FILED ON FEBRUARY 8TH, 2002 AS FILE NUMBER 2002-0112862 IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY BENCHMARK THE BENCHMARK FOR THIS SITE IS A CITY OF CARLSBAD SURVEY CONTROL MONUMENT DESIGNATED AS A 2-112" BRASS DISK MARKED "CLSB-098" ON THE CURB AT THE SOUTHEAST CORNER OF ORION STREET AND ORION WAY PER CITY OF CARLSBAD RECORD OF SURVEY NUMBER 17271. ELEVATION: 338.892 FEET (NGVD-29) PROJECT LOCATION THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBER(S): 209-120-27-00, 209-120-20-00 EARTHWORK QUANTITIES GRADED AREA CUT QUANTITIES FILL QUANTITIES EXPORT J:iQEi. 0.07 ACRES 140CY 47CY 93CY THE GRADING QUANTITIES ABOVE ARE AN ESTfMA TE FOR PERMITTING PURPOSES ONLY. THE EARTHWORK ASSUMES A 10-fNCH ASPHALT PAVING SECTION WITHIN THE PARKING LOT/DRIVE AISLE AREA, AN 8-fNCH BUILDING PAD, 6-fNCH SITE CONCRETE THICKNESS, AND BfOFIL TRA TfON BASIN SECTION SPOILS. THE GRADING QUANTITIES SHOWN ABOVE DO NOT ACCOUNT FOR VARfA T/ONS DUE TO LOSS FROM CLEARING AND GRUBBING, STRIPPING, SHRINKAGE, SWELL, UNSUITABLE MATERIALS, REMEDIAL GRADING, UTILITY TRENCH SPOILS, ETC. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THEIR OWN INDEPENDENT QUANTITY & MATERIAL TAKE-OFFS TO CONSTRUCT THE DESIGN AS IND/CA TED ON THESE ORA WINGS & IN CONFORMANCE WITH THE PROJECT'S GEOTECHNICAL REPORT & SUBSEQUENT UPDATE LETTERS. DISTURBED & IMPERVIOUS AREA TOTAL LOT AREA= 18.46ACRES TOTAL DISTURBED AREA= 0.08 ACRES {THIS AREA INCLUDES BUT IS NOT LIMITED TO OFF-SITE WORK INCLUDING TEMPORARY DISTURBANCE SUCH AS VEHICLE AND EQUIPMENT STAGING AREAS, CONSTRUCT/ON WORKER FOOT TRAFFIC, SOIUGRA VEL PILES, UTILITY TRENCHES, BACKFILL CUTS & SLOPE KEYWAYS) POST-CONSTRUCT/ON BMP TABLE STORMWA TER REQUIREMENTS THAT APPLY: D STANDARD STORM.WATER REQUIREMENTS ~ PRIORITY PROJECT REQUIREMENTS EXEMPT FROM HYDROMODIFICA TION? EXEMPT FROM TRASH CAPTURE? D YES DYES ~ NO ~ NO WORK TO BE DONE THE GRADING WORK SHALL CONSIST OF THE CONSTRUCTION OF ALL CUTS & FILLS, REMEDIAL GRADING, DRAINAGE FACILITIES, EROSION CONTROL FACILITIES, & PLANTING OF PERMANENT LANDSCAPING AND PREPARA TfON OF AS-BUfL T GRADING PLANS, AS-BUILT GEOLOGIC MAPS AND REPORTS, ALL AS SHOWN OR REQUIRED ON THIS SET OF PLANS AND THE CITY ST AND ARDS, SPEC/FICA TIONS, REQUIREMENTS, RESOLUTIONS AND ORDINANCES CITED ON THESE PLANS. THE GRADING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING DOCUMENTS, CURRENT AT THE TIME OF CONSTRUCTION, AS DIRECTED BY THE CITY ENGINEER. 1. CARLSBAD MUNICIPAL CODE. 2. CITY OF CARLSBAD ENGINEERING STANDARDS. 3. THIS SET OF PLANS. 4. RESOLUTION NO. 7472 DATED OCTOBER 13, 2016. 5. STANDARD SPECIF/CATIONS FOR PUBLIC WORKS CONSTRUCT/ON (GREEN BOOK). 6. SOILS REPORT AND RECOMMENDATIONS BY GEOCON, INC. PROJECT NO. 06442-32-31A DATED OCTOBER 19, 2021 AND MARCH 22, 2023. 7. SAN DIEGO REGIONAL STANDARD ORA WINGS AND AS MAY BE MODIFIED BY THE CITY OF CARLSBAD STANDARDS. 8. CALIFORNIA COASTAL COMMISSfONDEVELOPMENTPERMITCONDITIONSDATE NIA . 9. ENVIRONMENTAL APPROVAL DOCUMENTS DATED AUGUST 2002. 10. STORM WATER POLLUTION PREVENTION PLAN, PREPARED BY PLSA DA TED APRIL 2023. WDfD NO. 9 37C401066. 11. STORM WATER QUALITY MANAGEMENT PLAN, PREPARED BY PLSA DA TED APRIL 2023. 12. CALIFORNIA STORM WATER QUALITY ASSOC/A TION BMP CONSTRUCTION HANDBOOK AND CAL TRANS CONSTRUCTION SITE BMP MANUAL. DESCRIPTION RIGHT-OF-WAY .. LOTLINE CENTERLINE PROPOSED CONTOUR EXISTING CONTOUR SPOTELEVATION. FLOW DIRECTION AND SLOPE. LIMIT OF GRADING .. SETBACK LINE 6" CURB AND GUTTER . 6'CURB RETAINING WALL. 4' PCC SIDEWALK LEGEND DWG.NO. . . . . . . . . . . . . . SDRSD G-2 (TYPE Gr .SDRSD G-1 . . . ,SHEET 5, 6-12 24" HDPEJRCP STORM DRAIN PIPE . STORM DRAIN CLEANOUT (TYPE A} . TRUNCATED DOMES DS-2' D-61. . SDRSD D-09 . ... SDRSD G-30 TRASH CAPTURE DEVICE CUTOFF WALL. 4'ASPHALTCONCRETE DESCRIPTION EXISTING WATER EXISTING RECYCLED WATER EXISTING SEWER .. EXISTING STORM DRAIN. EXISTING SEWER MANHOLE EXISTING WATER METER EXISTING FIRE HYDRANT . EXISTING WATER VALVE. EXISTING STREET LIGHT . DETAIL A SHEET 4. .SDRSDD-72 EXISTING IMPROVEMENTS DWG.NO. EXISTING MONUMENT (PROTECT IN PLACE) EXISTING fRRfGA TION WATER SERVICE. . SYMBOL QUANTITY --- -•RIW- -----CA.- ---293 --- ---293 --- 293.00 TC 2.0% - \V \V 1,100 SF . ___ sp---..... 86LF. llQll ...... 1EA. ~ SYMBOL --w----RW----S ----SD--- ~ [XX] ® ~ • -------1(D .1 EA . .1 EA ALL STANDARDS ARE SAN DIEGO REGIONAL STANDARD DRAWINGS (SDRSD) UNLESS NOTED OTHERWISE. ' CITY OF CARLSBAD STANDARD DRAWINGS. " AS MODIFIED BY CITY OF CARLSBAD STANDARD ORA WINGS. NOTE: ALL QUANTITIES SHOWN HEREON ARE FOR BONDING PURPOSES ONLY; THE CONTRACTOR IS RESPONSIBLE -ro!TTHEIR OWN INDEPENDENT QUANTITY & MATERIAL TAKE-OFFS TO CONSTRUCT THE DESIGN AS INDICATED ON THESE ORA WINGS. TYPE DESCRIPTION OWNERSHIP MAINTENANCE SHEET MAINTENANCE AGREEMENT NO. FREQUENCY CONNECTOR TRASH CAPTURE PIPE SCREEN (MODEL NO. PRIVATE YES 3, 4, 5 SEMf-ANNUALL Y BWCPS-3624U) •~s BUILT" BMPS SEE GR 2018-0040 DWG. 514-7A RCE __ _ EXP. ___ _ DATE REVIEWED BY: INSPECTOR DATE &rw.l, PASCO LAREY SUITER l----+--+------------+---+----+---+------11 SH1EET I CITY OF CARLSBAD ~3 ENGINEER/NG DEPARTMENT L_1;!_j ;:P::::R:::Ec=,s=E=G::.RA-==o,=N=G::::PLA==N=s==Fo=R=,==========-===::::: "' No. RCE 6B075 . 06-30-2 Know what's be low. Call before you dig. R. C.E. NO. 68075 ~ ~SSOC!~llES San Diego I Encinitas Orange County Phone 858.259.8212 I www.plsaengineering.com ENGINEER OF WORK 2/9124 DATE EXP. 06-30-25 OA!E INITIAL OA!E INmAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL DA!E INITIAL CITY APPROVAL JONIS CONFERENCE CENTER PEDESTRIAN/ ADA IMPROVEMENTS FOR /ONIS LOTS 21/22 TITLE SHEET GR 2023-0009 APPROVED: JASON S. GELDERT ENGINEERING MANAGER OWNBY: ,/T CHKDBY: RVWDBY: RCE63912 EXPIRES 9130/24 PROJECT NO. SOP 2021-0029 SDP2021-0029 DATE DRAWING NO. 540-7B Docusign Envelope ID: 566A09F6-B29F-4FA5-B4FC-7971AA550EDF 9/30/2024 NFNF 0 0 0 w --- LOT22 MAP 16145 -r ---/_~. "'" :SC:----o= WH/PT,1/L LOOP • ~ w w ~ OPEN SPACE LOT12 MAP 14926 PROP. LOT 1 8.37 AC (364,697 SF) 111 1 ° EXISTING LOT LINE TO BE REMOVED PER LOT LINE ADJUSTMENT (COC2022-0011) ,, ~ ~ w 11 3 --• SPECIAL NOTES PRIVATE ENGINEER'S NOTICE TO CONTRACTOR THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY THE CONTRACTOR SO THAT ANY NECESSARY ADJUSTMENTS CAN BE MADE IN ALIGNMENT AND/OR GRADE OF THE PROPOSED IMPROVEMENTS PRIOR TO INSTALLATION. THE CONTRACTOR IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO PROTECT ANY AND ALL UTILITY LINES NOT ON RECORD OR SHOWN ON THESE PLANS. ALL DRY UTILITIES SHOWN ON THE PLANS ARE APPROX/MA TE AND FOR REFERENCE ONLY, SOLELY FOR THE CONVENIENCE OF THE CONTRACTOR. THE CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE FRANCHISE UTILITY TO DETER.MINE THE LOCATION OF UNDERGROUND SERVICES PRIOR TO THE START CONSTRUCTION. CONTRACTOR TO POTHOLE ANY AND ALL UTILITY CROSSINGS PRIOR TO CONSTRUCTION TO ENSURE EXISTING IMPROVEMENTS' ALIGNMENTS AND GRADE MATCHES THE PLANS. IF DISCREPANCIES ARE NOTICED, NOTIFY ENGINEER OF WORK PRIOR TO INSTALLATION TO ADJUST ALIGNMENT AND I OR GRADE OF PROPOSED IMPROVEMENTS AS NECESSARY. CALIFORNIA COUNCIL OF CIVIL ENGINEERS AND LAND SURVEYORS CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCT/ON OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL. ' \ i i w_ I "' ~I )i; ~ r-r- 0 O 4 KEY MAP SCALE 1"= 50' 5 0 0 LOT21 MAP 16145 ', "--," "..:::-~ ~ ---~~~ ' ◊ Ct 50 100 150 GRAPHIC SCALE: 1" = 50' >-- ~ C LOT20 MAP 16145 1'~ • ss, ~ ~ ~ 4t " ~ '#" IV. ! I ~ * No. RCE 68075 XP. 06-30-2 Cfvll R.C.E. NO. 68075 ~ ~ ~ ~ t. PREPARED BY: PASCO LAREY SUITER i ~5;5,(0)(C!~l[E5; San Diego I Encinitas Orange County Phone 858.259.8212 I www.plsaengineering.com ENGINEER OF WORK 219124 DATE EXP. 06-30-25 ABBREV/A TIONS: AC ACRE I ACREAGE APN ASSESOR PARCEL NO. BMP BEST MANAGEMENT PRACTICE BO BLOW-OFF CAV COMBINATION AIR VALVE CB CATCH BASIN C/P CAST-IN-PLACE C/L CENTERLINE CMU CONCRETE MASONRY UNIT co CLEANOUT CY CUBIC YARDS C&G CURB AND GUTTER DIA DIAMETER DWY DRIVEWAY ESMT EASEMENT EX EXISTING ff FINISHED FLOOR FG FINISHED GRADE FH FIRE HYDRANT FL FLOW LINE FS FINISHED SURFACE GB GRADE BREAK GV GATE VALVE H HEIGHT IE INVERT ELEVATION LIL LOT LINE MAX MAXIMUM MIN MINIMUM MH MANHOLE MWS MODULAR WETLAND SYSTEM PL PROPERTY LINE POC POINT OF CONNECTION PROP PROPOSED RCP REINFORCED CONCRETE PIPE R/W RIGHT OF WAY SD STORM DRAIN Sf SQUARE FEET SFM SEWER FORCED MAIN SMH SANITARY SEWER MANHOLE ss SANT/ARY SEWER TB TOP OF BERM TC TOP OF CURB TW TOP OF WALL TYP TYPICAL w WATER WM WATER METER R/W 5.5' 4.5' 26' EX. LANDSCAPE I 2% ,. WHIPTAIL LOOP C/L 2% 26' 4.5' 5.5' EX. LANDSCAP s, • sB'R§e':13 • ~ '<:/..',..,,'-<-. TYPICAL STREET SECTION-WHIPTAIL LOOP NOTTO SCALE T.I. = 7.0 •~s BUILT" RCE __ _ EXP. ___ _ REVIEWED BY: INSPECTOR R/W DATE DATE ~~----1------------1---1----1-----1----I I.._S=H2E=ET=l-==C=l=T=Y=O=F==C=A=R=L=S=B=A=D===I =J=I ~ ENGINEER/NG DEPARTMENT DATE INITIAL DATE INITIAL DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL PRECISE GRADING PLANS FOR: JONIS CONFERENCE CENTER PEDESTRIAN! ADA IMPROVEMENTS FOR JONIS LOTS 21122 KEY MAP GR 2023-0009 APPROVED: JASON S. GELDERT ENGINEERING MANAGER RCE 63912 EXPIRES 9130/24 DWNBY: CHKDBY: RVWDBY: .IT PROJECT NO. SDP 2021-0029 SDP2021--0029 DATE DRAWING NO. 540-lB Docusign Envelope ID: 566A09F6-B29F-4FA5-B4FC-7971AA550EDF 9/30/2024 NFNF I 1 /I I (5 ! -~-.:__,I I .-.._ EXIST. 36" RCP SD ~...g"" PER DWG. NO. 415-9J r 8' PRECISE GRADING & STORM DRAIN PLAN SCALE 1" = 20' PROP BRIDGE RAMP PROP. LANDSCAPE RET. WALL 'H' EX. LANDSCAPE SECT/ONG SCALE 1"= 1' SECTIOND SCALE 1"= 1' PROP. LANDSCAPE 0 20 40 GRAPHIC SCALE: 1" = 20' 1!2"R * I I 2 423.13 TC 422.63FS ,~:,:~ 'l 423.43 TC 422.93 FS ! ' ....................... I I I I EXIST. CO \ 423.35 TC 422.85 FS '1 I I I I I I 1'-6" 3-518" LEVA TION PT. ON PLANS "' 0: !.l! ::, -<.) ..., (422.60 RIM) --- ASPHALT PAVING -tt-112" 2"WEAKENED PLANE JO/NT NOTES: 1. CONCRETE SHALL BE 520-C-2500 2. PROVIDEJOINTSPERSDRSDG-09, G-10 3. SEE SDRSD G-4A FOR ADDITIONAL DETAILS 22.67 FS ,,, • ". 422.67 FS ~ (I MATCHEXIST. ~· (424.0± TC) ~ /423.5± FS) ---------PEDESTRIAN RAMP DETAIL SCALE 1" = 10' MODIFIED ROLLED CURB PER DETAIL A THIS SHEET MODIFIED -6" ROLLED CURB TYPE A ROLLED CURB TRANSITION DETAIL NOTTO SCALE EXISTING CLEANOUT '\. (PUBLIC) \.,_ GROUT INTERIOR WALL TO FILL GAPS AS NEEDED Ii 1' PROPOSED RGPSTORM DRAIN ,:\ <1 = -~ -t::=-'/4 . i--: = . . . ,:\ CONCRETE J LUG ;.. ® STORM DRAIN CONNECTION 6"CURBPER SDRSD G-1 NOTTO SCALE - - NOTTO SCALE GRADING CONSTRUCTION NOTES: (D CONSTRUCT 4" P.C.C. WALK 2% MAX. CROSS SLOPE @ CONSTRUCT 6" P.C.C. CURB PER SDRSD G-01 @ CONSTRUCT RETAINING WALL PER STRUCTURAL PLANS, SHEETS 7-15. SEE RETAINING WALL PROFILE ON SHEETS 4. (1) CONSTRUCT TRUNCATED DOMES PER SDRSD G-30 @ CONSTRUCT O" CURB @ REMOVE/REPAIR AG PAVEMENT. 4" AC OVER 4" BASE TO BE VERIFIED IN THE FIELD WITH THE R-VALUE TEST (D INSTALL 24" TALL CONNECTOR PIPE SCREEN MODEL NO. BWGPS-3624U (TRASH CAPTURE) BY BRIGHTWA TER @ REMOVE EXISTING STORM DRAIN @ PROPOSED GONGRET.E PIPE ENCASEMENT PER SDRSD SP-03.11'/STALL 1" NEOPRENE PAD (OR EQUAL) BETWEEN PIPE AND CONCRET.E. @) INSTALL MODIFIED 6" ROLLED CURB PER DETAIL A ON THIS SHEET @ CONSTRUCT STORM DRAIN CLEANOUT -TYPE :<\-4' PER SDRSD D-09 @ ADA PARKING STALL PER SDRSD M-27A @ TRANSITION MODIFIED ROLLED CURB TO 6" CURB PER DETAIL B THIS SHEET @ STORM DRAIN CONNECTION PER DETAIL C THIS SHEET. @ REPAIR SIDEWALK PER DWG 540-7 PA PLANTER AREA PER LANDSCAPE PLANS PRIVATE STORM DRAIN DATA NO. DELTAIBRG LENGTH SLOPE REMARKS (J) N63°10'40"E 38.47' 24.49% 24"HDPE Q) N24°34'16"W 47.11' 14.40% 24"RCP PRIVATE PVC & HDPE STORM DRAIN PIPE NOTES: 1. HOPE PIPE SHALL BE N-12 WATER TIGHT BY ADS OR EQUAL, UNLESS OTHERWISE NOTED. ALL PIPE LENGTHS ARE MEASURED FROM INSIDE WALL OF STRUCTURE TO INSIDE WALL OF STRUCTURE, AND CENTER OF FITTING TO GENTER OF FITTING. PIPE BEDDING AND BACKFILL PER CITY OF CARLSBAD DS-2 2. PVC PIPE SHALL BE SDR-35, ASTM 3034, ASTM F477 UNLESS OTHERWISED NOTED. PIPE BEDDING AND BACKFILL PER SDRSD D-60. 3. ALL PIPE LENGTHS SHOWN HEREON ARE APPROX/MA TE ONLY. CONTRACTOR IS RESPONSIBLE FOR ALL QUANTITY TAKEOFFS TO CONSTRUCT THE DESIGN SHOWN ON THESE PLANS. 4. MIRAFI 140N FABRIC PLACED OVER PIPE ZONE BACKFILLED WITH i" GRAVEL FOR HOPE STORM DRAIN LINES 18" OR GREATER FOUND MONUMENTS: @ FOUND L&D WI DISK STAMPED "RCE 27214" PER MAP 16145. @ FOUND M10 WI DISK STAMPED "RCE 27214" PER MAP 16145. SIGNING AND STRIPING: @ ADA STALL SIGNAGE PER SDM-117 NON-MAPPING NOTES 0 PARKING ONLY MINIMUM FINE $250 1. NO STRUCTURE, FENCE, WALL, TREE, SHRUB, SIGN, OR OTHER OBJECT OVER 30 INCHES ABOVE THE STREET LEVEL MAY BE PLACED OR PERMITTED TO ENCROACH WITHIN THE AREA IDENTIFIED AS A SIGHT DISTANCE CORRIDOR IN ACCORDANCE WITH CITY STANDARD PUBLIC STREET-DESIGN CRITERIA, SECTION 8.8.3. THE UNDERLYING PROPERTY OWNER SHALL MAINTAIN THIS CONDITION. •~s BUILT" RCE __ _ EXP. ___ _ DATE REVIEWED BY: INSPECTOR DATE ~ss, ,,-~w-~ PREPARED BY: PASCO LARET SUITER l----+---+------------+---+----+---+-----11 SH3EET I CITY OF CARLSBAD ~3 ENGINEER/NG DEPARTMENT L_1;!_j ;:P::RE==c=,s==E=G::RA=o=,N=G=P=LA=N=s=F=oR==:=========:::.::==::::::: 60 "' No. RCE 68075 * XP. 06-30-2 Clvll R.C.E. NO. 68075 ~ ~SiSiO(C i~l[ESi San Diego I Encinitas Orange County Phone 858.259.8212 I www.plsaengineering.com ENGINEER OF WORK 219124 DATE EXP. 06-30-25 DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL JONIS CONFERENCE CENTER PEDESTRIAN! ADA IMPROVEMENTS FOR JONIS LOTS 21122 PRECISE GRADING & STORM DRAIN PLAN GR 2023-0009 SDP2021--0029 APPROVED: JASON S. GELDERT ENGINEERING MANAGER RCE 63912 EXPIRES 9130/24 DATE OWNBY: CHKDBY: RVWDBY: .IT PROJECT NO. SDP 2021-0029 DRAWING NO. 540-78 Docusign Envelope ID: 566A09F6-B29F-4FA5-B4FC-7971AA550EDF 9/30/2024 NF NF -- PREPARED BY: --- : llffii--l--~o lhiol I I I I sD-K: i usTAINABLE ~ 1 l , LAIi N1CAPING ( I T 111 i I I I 11 I I I ij I I I I 11 I I I 11 I I ~I I I r SINGLE SHEET BMP SITE PLAN SCALE 1" = 40' DEFLECTOR STANDARD MODELS (36-INCH) HINGED LID PLATE "U" CONFIGURATION ASSEMBLY Net Maximum Trash Bypass Screen Screen Screen Screen Open Model Number Width1 Length2 Area3 Treatment Storage capacity Height Screen Flow Rates Capacitl ' ' _)L-Area " c::, 0 Model No. (in) (in) {ft) (ft2. (ft:!} {ds) (yd~) {ds) SUPPORT BWCPS-3612U 36 12 /J.77 /J.77 2.-13 '1.78 0.60 15.89 HOOPS --" ~-BWCPS-3618U 36 1E 4.77 7.16 3.65 8.79 0.91 15.89 z BWCPS-3b24U ':36 24 4.77 ':l.54 4.87 l'::t53 1.21 15.8':l .,,___ BWCPS 3630U 36 30 4.77 11.93 6.08 18.91 1.51 15.89 ;c, 0 BWCPS-3636U 36 36 4.77 14.31 7.30 24.86 1.81 15.89 lhlltclullm-mstinl,nl,molm& ----Ollllc:wbo,Eft~-1abl,. IJALL Llh,Wlt!"~ le51heds'-"tn,n-lheffll'"~~--:£.J;~p\,e, ,-BRACKET !t~£~~~~ir1:~.riQft-&~;v~:~:arc~~~Fn~t·~~~~= • 27.31 0 24.16 V .,..,.. CONNECTOR PERFORATED MESH,_____....--P!Pl ~ r---r----SCREEN ~o -.....___ - ISOMETRIC VIE\./ -CPS/DEFLECTOR PLATE / SCALE, NTS CATCH BASIN -, ,-7 NOTES, I. ALL CDMP□NETS SHALL BE MANUFACTURED FROM IJALL 12.2 GRADE 304 STAINLESS STEEL. 2. PERFORATED MESH SCREEN SHALL BE 14GA, 304 CPS STAINLESS STEEL, 3/16' (5MM) MAX HOLE SIZE, 451. MINIMUM □PEN AREA. 3. THE DEFLECTOR PLATE ASSEMBLY MAY BE TOP SECTI□N VIEIJ -CPS/CATCH BASIN NECESSARY FDR APPLICATIONS IJITH FLDIJ SCALE, NTS ENTERING DIRECTLY ABOVE THE CPS. TITLE: -DATE ~¾,~·. . '' CONNECTOR PIPE SCREEN "'"" ... mm/2020 i •·t Bright Water CfECKE] .. 01/24/2020 '"' ..._ "'' 01/24/2020 // u // CDNFIGURA TIDN tF!i APPR. Ell( Oi!/O4/2112D :~s'ffi'il' ~:-· QA IWi 112/116121121] ~/,.\'<' UNLESS OTHERVIS£ SPECIFIED P,D, Box 85430 I Son Diego, Colifornio 92186 I (619) 821-1558 DDENSIIMS Mr IN INCIES www.wearebriahtwa ter ,coM TlliRAMD SIZE Dw'G, NO. REV SCALE, li12 DD NOT SCALE DRAw'ING In""" 304 STAINLESS STEE FRACTIIIW.± 1/32 A B'w'CPS-U-0001 A NGI.ARi MACH :t 0.5 Ei IENOt 1.0 IE!i TIIE Df1RMATillii ~TADD IN THIS DIA\/Dli IS Tl£ SO.E PRIPERTY IF BlllifTVATER. Ill« 1Vll Pl.AC[ IECIHAL :t 11.30 SHEET 3 OF 5 li!EPORDDJCTD IN PIIRT Ill AS A \itn.E VITIOJT Tl£ \iRTEEN PERMISSD □r BIIGHTYATER IS PIUOBTED. TIIIEE PLACE IECIIWJ 0.020 i'A'\BRIGHTWATER CONNECTOR PIPE SCREEN DETAIL ' 4 , NOTTO SCALE - PASCO LARET SUITER I fa\§§(Q)(C!fa\TIE§ San Diego Encinitas Orange County Phone 858.259.8212 I www.plsaengineering.com 0 20 40 60 GRAPHIC SCALE: 1" = 40' R.CE NO. 68075 LOT20 MAP 16145 ENGINEER OF WORK EXP. 06-30-25 219124 DATE PARTY RESPONSIBLE FOR MAINTENANCE: NAME 2850 21155 2859 GAZELLE OWNER !DEi LLC ADDRESS 450 PARK AVE 9TH FLOOR CONTACT _____ _ NEWYORK NY10022 PHONE NO. !6461 376 3100 PLAN PREPARED BY: -Pl NAME GREGORYW, LANG ~~ k). ~ cfNATURE COMPANY PASCO LARET SUITER AND ASSOCIATES ADDRESS 119 ABERDEEN DRIVE CARDIFF CA 92007 PHONE NO. !8581 259 8212 BMPNOTES: CERTIFICATION ____ _ 1. THESE BMPS ARE MANDATORY TO BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS OR THESE PLANS. 2. NO CHANGES TO THE PROPOSED BMPS ON THIS SHEET WITHOUT PRIOR APPROVAL FROM THE CITY ENGINEER. 3. NO SUBSTITUTIONS TO THE MATERIAL OR TYPES OR PLANTING TYPES WITHOUT PRIOR APPROVAL FROM THE CITY ENGINEER. 4. NO OCCUPANCY WILL BE GRANTED UNTIL THE CITY INSPECTION STAFF HAS INSPECTED THIS PROJECT FOR APPROPRIATE BMP CONSTRUCT/ON AND INSTALLATION. 5. REFER TO MAINTENANCE AGREEMENT DOCUMENT. 6. SEE PROJECT SWQMP FOR ADDITIONAL INFORMATION. BMP CONSTRUCTION AND INSPECTION NOTES: THE EOW WILL VERIFY THAT PERMANENT BMPS ARE CONSTRUCTED AND OPERA TING IN COMPLIANCE WITH THE APPLICABLE REQUIREMENTS. PRIOR TO OCCUPANCY THE EOW MUST PROVIDE: 1. PHOTOGRAPHS OF THE INSTALLATION OF PERMANENT BMPS PRIOR TO CONSTRUCT/ON, DURING CONSTRUCT/ON, AND AT FINAL INSTALLA T/ON. 2. A WET STAMPED LETTER VERIFYING THAT PERMANENT BMPS ARE CONSTRUCTED AND OPERA TING PER THE REQUIREMENTS OF THE APPROVED PLANS. 3. PHOTOGRAPHS TO VERIFY THAT PERMANENT WATER QUALITY TREATMENT S/GNAGE HAS BEEN INSTALLED. PRIOR TO RELEASE OF SECURITIES, THE DEVELOPER IS RESPONSIBLE FOR ENSURING THE PERMANENT BMPS HAVE NOT BEEN REMOVED OR MODIFIED BY THE NEW HOMEOWNER OR HOA WITHOUT THE APPROVAL OF THE CITY ENGINEER. SITE DESIGN & SOURCE CONTROL BMPS: BL-1: EXISITNG NATURAL SITE FEATURES I SD-G I CONSERVE NATURAL AREAS BL-2: OUTDOOR IMPERVIOUS AREAS I SD-8 I IMPERVIOUS AREA DISPERSION BL-4: LANDSCAPED AREAS I SD-K I SUSTAINABLE LANDSCAPING 1-: -: -: . I BL-5: WORK AND STORAGE AREAS I SC-A I OVERHEAD COVERING I SC-8 I BERM AND GRADE BREAKS I SC-8 I WIND PROTECTION BL-7: MANAGEMENT OF NON-STORMWA TER DISCHARGES I SC-F I STORM DRAIN S/GNAGE I SC-G I EDUCATIONAL BMP SIGNAGE POST-CONSTRUCTION BMP TABLE STORMWATER REQUIREMENTS THAT APPLY: D STANDARD STORMWATER REQUIREMENTS C8J PRIORITY PROJECT REQUIREMENTS EXEMPT FROM HYDROMODIFICA TION? EXEMPT FROM TRASH CAPTURE? D YES D YES C8J NO C8J NO TYPE DESCRIPTION OWNERSHIP MAINTENANCE SHEET MAINTENANCE AGREEMENT NO. FREQUENCY CD CONNECTOR TRASH CAPTURE PIPE SCREEN (MODEL NO. PRIVATE YES 3, 4, 5 SEMI-ANNUALLY BWCPS-3624U) BMPS SEE GR 2018-0040 DWG, 514-7A •~s BUILT" RCE __ _ EXP. ___ _ DATE REVIEWED BY: INSPECTOR DATE l----+---+------------+---+----+---+-----11 SH4EET I CITY OF CARLSBAD ~3 ENGINEER/NG DEPARTMENT L__.1;!_j ;:P::RE==c=,s==E=G::RA=D=,N=G=P=LA=N=s=F=OR::::,=========:::..::==::::::: DATE INITIAL DATE INITIAL DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL JONIS CONFERENCE CENTER PEDESTRIAN/ ADA IMPROVEMENTS FOR JONIS LOTS 21122 SINGLE SHEET BMP SITE PLAN GR 2023-0009 SDP2021--0029 APPROVED: JASON S. GELDERT ENGINEERING MANAGER RCE 63912 EXPIRES 9130/24 DATE DWNBY: CHKDBY: RVWDBY: .IT PROJECT NO. SDP 2021-0029 DRAWING NO. 540-7B Docusign Envelope ID: 566A09F6-B29F-4FA5-B4FC-7971AA550EDF 9/30/2024 NFNF 44.74' CMU RETAINING WALL SEE SHEET 13 FOR FOOTING DETAILS 31.41' SEE DETAIL 6 SHEET 11 I 1+12.00 425.33 TW '\ I r 1-13.3 'SEE DETAIL 8 S EET 11 ::I ~-t-- 1+28.58 ;:!: ~ c -- 51.54' GMU RETAINING WALL I SEE SHEET 12 FOR FOOTING DETAILS 21.34' SEE DETAIL 6 SHEET 11 I r-30.20' SEE DETAIL 8 SHEET 11 1+00.00 1+10.67 I BEGIN WALL ". -425.33 TW \ 425.33TW ". ~--.--:>1----.....:,, I 424.67 TW :i' Q ~ a--+--42~!'r-t------;------+--+--+~ l----->------+--l ----+-~~~--+------+-----+------+------+-----+-------1>------+--42~!'r-t------;------+-----+-----+-----+-----+---+-+-t. ---I --- --+------+-----+------+------ - -----------PROPOSED GRADE_/ - --== F -.;; ATTOPOFWALL --_ PROPOSEDGRADE --AT~~~ -~==~=~~ --l.. --+------+-------+------+------+------+-----l--------lt-------+------+-----+------+------+-----+-------1>---- I -- I PROPOSED GRADE~ AT BOTTOM OF WALL --------- I EXISTING SURFACE V / 1~ a-+--42Ct 1--1------1------+--+--+-1 I _J_ WALL, MIN. 1.0% SLOPE / ---I 4"SUB-DRAINATBACKOF ~ ,,t---j------t-------t-------t-------t------j-----t-----jr--42Ct l--t------1------+-----+-----+-----+-----+---+-+-I I . -----4 ----l-----+-----+----+-,42C EXISTING SURFACE )/ / 1 /---- ATBOTTOMOFWALL // _>< / ------// -~ ---~-------........... ~ ------// ; / / --, / I I I ->-I // -I - I /1 ~ ~ ~ // I I II ! ~ cil +-----+-----+------+-----+----+------+------<f----+-----+-----+------+-----+----+------+---/ // 7 ll I; // I ij1 -~ -::i / ,f / 4"SUB-DRAINATBACKOF. ~ / I I g ~ ::;; / fl/ WALL, MIN. 1.0% SLOPE / I o O '° // ---'/~----,/j / l=~rll.-_\:;-7+ ! ; ---+-----+------+-----+-------lt------+-----+------+-41 i . ..,_---1-----+-----+------+-----+-------tt------+--~~-+---+-1 / Jf I / // I 8 ~ ... / ;/ I /~/ __ J2~ / !} I // ; I /~/ I I I~ I I /~/ -I I t1 // / // I /;/ I 11 / // I -// ~ a--+--41 i-..,__-1--------1-----+-__,.;a;+--+-I \t-' l------+------+-----1-------+------+-------+------+--41 i . ..,_-+__. / /;/ I , I 1f _ __,t--_/_,I ,.:,/ ___ ~1 ---~ !;; -'-~ ~ ----+------+------+------+----->------+------+-------+------+--4101 >-->------+------+-------+------+------+------+-----+---.,_-/i-----1 -l€ !;; -~ ~ ->-------1t-------+------+-----+------+------+--411.,1 1--+__. / 11" ~ ~ I ~ ~ // ~ ~ ~ ~ --+--4101 >---I-----+-----+---+--+--+ _/ 1? -11~-~-\~i-~~ --,? gi~ -1 -;= // ,.._ .., // (::: ~ // _____ I!~ PROP.BOTTOMOFKEY // ~ gl // ... // ... // -// , \ // ,, --// II I \ // I I '/ 'I I / " I I . \ ~-\ ; / \ I / ........ -40:;~-+-----+----+--- --------,f------+-'-•,...,,✓ ~-+-------+------+----+----+-----+-------+------+----+--40:;~-+-----+----+----f------+----+-----+--· 8 :::I~ ~ ~ f-3 ~ ~ ~ '---PROP.24"HDPE g ::I~ / - ~ ~ ~ ~ ~ u &3 ~ ~ STORM DRAIN g ~ ~ ~~~ ~~~~ ~~ ~~~ (B~-~,. ~ ~ 405.39/E QJ!;J!- LLJ CIJ~ ~ OJ ~f2 ..... .... ! 1+00 WALL 'H' PROFILE HORIZ. SCALE: 1" = 1 O' VERT. SCALE: 1" = 2' 1+50 - TOP OF WALL~ ,-PROPOSED BROW DITCH PER SDRSD D-75, TYPE B r FINISH GRADE / _1 , PROPOSED DRAINAGE PANEL 1 '--;: (MIRADRAIN 6000 OR ~/i 1, APPROVED EQUAL) -/~PROPOSED WATER PROOFING / PER ARCHITECTURAL SPEC SECTION 0713 25 BOTTOM OF WALL\ FINISH GRADE \ ,..';, TOP OF FOOTING I I I 1;::;::a,u ·-t11;:;;Ilt- ',---_J - I 12" t-------1-MIRAFI 140N OR I EQUAL 4"PERFPVC i" CRUSHED ROCK (1 CF/FT • A , TYPICAL RETAINING WALL DRAINAGE DETAIL , 5 1 NOTTOSCALE - RETAINING WALL DATA TABLE I 1+00 SCALE 1" = 10' WALL 'I' PROFILE HORIZ. SCALE: 1" = 1 O' VERT. SCALE: 1" = 2' 1+50 •~s BUILT" INSPECTOR DATE ~ NO. DELTAIBRG RADIUS LENGTH (]) N26°53'06"W -28.58' l----+---+------------+---+----+---+------11 SHSEET I CITY OF CARLSBAD ~3 ENGINEER/NG DEPARTMENT L__.1;!_j ;:P::R:::Ec=1s==E=G::.RA.::::o,=N=G==PLA=N=s==Fo=R=:=============::::: San Diego I Encinitas I Orange County Phone 858.259.8212 I www.plsaengineering.com 0 10 20 GRAPHIC SCALE: 1" = 10' 0 N67°21 '50"W @ N26°53'06"W 0 /J.=2.73° 30 R.C.E. NO. 68075 -16.16' -18.86' 684.66 32.68' ENGINEER OF WORK 219124 DATE DATE INITIAL EXP. 06-30-25 ENGINEER OF WORK DATE INITIAL DATE INITIAL REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL JONIS CONFERENCE CENTER PEDESTRIAN/ ADA IMPROVEMENTS FOR JONIS LOTS 21122 RETAINING WALLS 'H' & 'I' PLAN & PROFILE GR 2023-0009 SDP2021--0029 APPROVED: JASON S. GELDERT ENGINEERING MANAGER RCE 63912 EXPIRES 9130/24 OWNBY: CHKDBY: RVWDBY: ,IT PROJECT NO. SOP 2021-0029 DATE DRAWING NO. 540-78 Docusign Envelope ID: 566A09F6-B29F-4FA5-B4FC-7971AA550EDF 9/30/2024 NFNF ~ C\i N Cl) I C: lll 0.. 2 en ~ Ql -C: Ql C) ..... C: 0 C) .!!2 C: .Q C') .... ~ a a ~ ~ Ql ,:;; Cl) ""O 0 C) .!!2 C: 0 ~ rt) u 0 0 -"' rt) Ql ""O 0 -:, <( DESIGN CRITERIA SCOPE: NEW CONSTRUCTION CODE: 2022 CALIFORNIA BUILDING CODE, REFERRED TO AS "THE CODE" GOVERNING JURISDICTION: CARLSBAD SEISMIC CRITERIA: SITE CLASSIFICATION ............................................ = D RISK CATEGORY ..................................................... = II SEISMIC DESIGN CATEGORY ................................ = D Ss = 0.926 g S1 = 0.341 g GENERAL Sos= 0.697 g S□1 = 0.445 g 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO STARTING CONSTRUCTION. DO NOT SCALE THE DRAWINGS. THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES OR INCONSISTENCIES. IN CASE OF CONFLICT, MORE COSTLY REQUIREMENTS GOVERN FOR BIDDING. SUBMIT CLARIFICATION REQUEST PRIOR TO PROCEEDING WITH WORK. 2. ALL DRAWINGS ARE CONSIDERED TO BE A PART OF THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REVIEW AND COORDINATION OF ALL DRAWINGS AND SPECIFICATIONS PRIOR TO THE START OF CONSTRUCTION. STRUCTURAL DRAWINGS INDICATE INFORMATION SUFFICIENT TO CONVEY DESIGN INTENT. IF ERRORS, INCONSISTENCIES OR OMISSIONS ARE DISCOVERED, THE ARCHITECT AND STRUCTURAL ENGINEER SHALL BE NOTIFIED PRIOR TO PROCEEDING WITH WORK. DEVIATION FROM THE APPROVED SET OF CONTRACT DOCUMENTS SHALL ONLY BE MADE AFTER WRITTEN APPROVAL BY THE ENGINEER OF RECORD. 3. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE GIVEN, CONSTRUCTION SHALL BE AS SHOWN FOR SIMILAR WORK. UNLESS NOTED OTHERWISE, DETAILS IN STRUCTURAL DRAWINGS ARE TYPICAL AS INDICATED BY CUTS, REFERENCES OR TITLES. 4. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE FOLLOWING CODES: LOCAL BUILDING CODE, AND ANY OTHER REGULATING AGENCIES WHICH HAVE AUTHORITY OVER ANY PORTION OF THE WORK, INCLUDING THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY, AND THOSE CODES AND STANDARDS LISTED IN THESE NOTES AND SPECIFICATIONS. 5. SEE ARCHITECTURAL DRAWINGS FOR THE FOLLOWING: A. SIZE AND LOCATION OF ALL DOOR AND WINDOW OPENINGS, EXCEPT AS NOTED. B. SIZE AND LOCATION OF ALL INTERIOR AND EXTERIOR NON-BEARING PARTITIONS. C. SIZE AND LOCATION OF ALL CONCRETE CURBS, EQUIPMENT PADS, PITS, FLOOR DRAINS, SLOPES, DEPRESSED AREAS, CHANGE IN LEVEL, CHAMFERS, GROOVES, INSERTS, ETC. D. SIZE AND LOCATION OF ALL FLOOR AND ROOF OPENINGS EXCEPT AS SHOWN. E. FLOOR AND ROOF FINISHES. F. DIMENSIONS AND ELEVATIONS NOT SHOWN ON STRUCTURAL DRAWINGS. 6. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR THE FOLLOWING: A. PIPE RUNS, SLEEVES, HANGERS, TRENCHES, WALL AND SLAB OPENINGS, ETC., EXCEPT AS SHOWN OR NOTED. B. ELECTRICAL CONDUIT RUNS, BOXES, OUTLETS IN WALLS AND SLABS. C. CONCRETE INSERTS FOR ELECTRICAL, MECHANICAL, OR PLUMBING FIXTURES. D. SIZE AND LOCATION OF MACHINE OR EQUIPMENT BASES, ANCHOR BOLTS FOR MOTOR MOUNTS. 7. SEE CIVIL DRAWINGS FOR THE FOLLOWING: A. BUILDING PAD AND FINISH GRADE ELEVATIONS AT ALL STRUCTURAL FOUNDATIONS. B. TOP OF WALL ELEVATIONS AT SITE AND RETAINING WALLS. 8. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. OBSERVATION VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS. 9. ALL REFERENCED STANDARDS (i.e. ACI, AISC, ASTM, ETC.) SHOWN IN THESE DOCUMENTS SHALL BE PER THE LATEST ADOPTED EDITION AS LISTED IN CHAPTER 35 OF THE CODE. 10. CONTRACTOR SHALL INVESTIGATE SITE DURING CLEARING AND EARTHWORK OPERATIONS FOR FILLED EXCAVATIONS OR BURIED STRUCTURES, SUCH AS CESSPOOLS, CISTERNS, FOUNDATIONS, ETC. IF ANY SUCH STRUCTURES ARE FOUND, STRUCTURAL ENGINEER SHALL BE NOTIFIED IMMEDIATELY. 11. CONSTRUCTION MATERIAL SHALL BE SPREAD OUT IF PLACED ON FRAMED ROOF OR FLOOR. LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. PROVIDE ADEQUATE SHORING AND/OR BRACING WHERE STRUCTURE HAS NOT ATTAINED DESIGN STRENGTH. 12. ALL CONSTRUCTION MEETING OR CROSSING EXPANSION OR SHRINKAGE CONTROL JOINTS IN FRAMED FLOORS OR ROOFS MUST HAVE PROVISIONS TO ACCOMMODATE THE MOVEMENT OR MUST BE DELAYED UNTIL THE JOINT IS CLOSED. 13. CONTRACTOR TO PROVIDE A LIST OF ALL PROPOSED SUBSTITUTIONS, WITH APPLICABLE MANUFACTURER'S ICC/IAPMO REPORTS, TO ARCHITECT, ENGINEER OF RECORD AND GOVERNING JURISDICTION FOR REVIEW AND APPROVAL BEFORE FABRICATION. 14. CONTRACTOR SHALL SUBMIT A WRITTEN "STATEMENT OF RESPONSIBILIT3/8" TO THE ARCHITECT OF RECORD AND GOVERNING JURISDICTION PRIOR TO CONSTRUCTION OF THE LATERAL FORCE RESISTING SYSTEM. THIS CONTRACTOR'S "STATEMENT OF RESPONSIBILIT3/8" SHALL COMPLY WITH CODE SECTION 1704.4. 10/12/20231:19:37 PM G E N E RA L S T R U C T U RA L N OT E S (G.S.N.) STRUCTURAL OBSERVATIONS STRUCTURAL OBSERVATION PER THE REQUIREMENTS OF THE CODE IS REQUIRED. THE STRUCTURAL ENGINEER WILL VISIT THE PROJECT AT THE FOLLOWING STAGES OF CONSTRUCTION: 1. STRUCTURAL OBSERVATION DOES NOT INCLUDE OR WAIVE THE INSPECTIONS REQUIRED BY THE CODE. 2. ALL OBSERVED DEFICIENCIES SHALL BE REPORTED IN WRITING TO THE OWNER'S REPRESENTATIVE, SPECIAL INSPECTOR, AND CONTRACTOR. A. THE CONTRACTOR SHALL ENSURE THAT ALL DEFICIENCIES NOTED BY THE STRUCTURAL ENGINEER IN STRUCTURAL OBSERVATION REPORTS ARE CORRECTED. SUCH COMPLIANCE SHALL BE REPORTED IN WRITING TO THE ENGINEER OF RECORD. B. THE SPECIAL INSPECTOR SHALL ENSURE THAT ALL DEFICIENCIES, RELATED TO SPECIAL INSPECTION TABLES, NOTED BY THE STRUCTURAL ENGINEER IN STRUCTURAL OBSERVATION REPORTS ARE CORRECTED. SUCH COMPLIANCE SHALL BE REFERENCED IN SPECIAL INSPECTOR REPORT. C. THE STRUCTURAL OBSERVER SHALL SUBMIT A FINAL WRITTEN STATEMENT TO THE GOVERNING JURISDICTION THAT SITE VISITS HAVE BEEN MADE AND IDENTIFYING ANY REPORTED DEFICIENCIES THAT HAVE NOT BEEN RESOLVED. THE STRUCTURE WILL NOT BE IN COMPLIANCE UNTIL THE DESIGNER HAS NOTIFIED THE GOVERNING JURISDICTION THAT ALL DEFICIENCIES ARE RESOLVED. MEP COORDINATION 1. THE STRUCTURAL PLANS INDICATE ONLY THE APPROXIMATE LOCATION OF MECHANICAL, ELECTRICAL AND OTHER EQUIPMENT, AS WELL AS THE RELATED FRAMING NECESSARY TO SUPPORT SUCH EQUIPMENT. THE FINAL POSITIONING OF THESE ITEMS IS DEPENDENT UPON THE EQUIPMENT PROVIDED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WORK BETWEEN SUBCONTRACTORS AND MANUFACTURERS. 2. THE FOLLOWING IS A LIST OF ITEMS THAT THE GENERAL CONTRACTOR NEEDS TO COORDINATE WITH THE MECHANICAL, ELECTRICAL AND PLUMBING CONTRACTORS. THIS LIST IS INTENDED TO BE AN AID TO THE CONTRACTOR AND IT IS NOT NECESSARILY ALL-INCLUSIVE. A. PENETRATIONS ARE NOT ALLOWED THROUGH RETAINING OR SITE WALLS, UNLESS SPECIFICALLY SHOWN ON THESE DRAWINGS. FOR OTHER PENETRATIONS, SUBMIT A LAYOUT PLAN TO THE STRUCTURAL ENGINEER FOR REVIEW. B. SEE THE POST-INSTALLED CONCRETE ANCHORS NOTE SECTION FOR ATTACHMENT INTO CONCRETE. FOUNDATION 1. FOUNDATION DESIGN BASED ON THE FOLLOWING SOILS REPORT: COMPANY: GEOCON. PROJECT NO: 06442-32-30A. DATE: MARCH 22. 2023. 2. FOOTINGS ARE DESIGNED BASED ON THE FOLLOWING INFORMATION: ALLOWABLE BEARING• = 2500 PSF (4000 PSF MAX WITH WIDTH AND DEPTH INCREASES) EQUIVALENT FLUID PRESSURE = 35 PCF: UNRESTRAINED WALLS O' TO 8' HIGH = 35 PCF + 7H: RESTRAINED WALLS 8+' = 35 PCF + 13H: RESTRAINED PASSIVE EARTH PRESSURE = 300 PCF COEFFICIENT OF FRICTION = 0.4 * ALLOWABLE BEARING MAY BE INCREASED BY 1/3 FOR WIND AND SEISMIC LOAD CASES. 3. FOOTINGS SHALL BEAR ON APPROVED COMPACTED FILL PER THE SOILS REPORT. VERIFY FOOTING ELEVATION WITH THE CIVIL DRAWINGS. MINIMUM DEPTH AND DIMENSIONS OF FOOTINGS SHALL BE AS FOLLOWS: MINIMUM DEPTH BELOW LOWEST ADJACENT GRADE ............ 2 FT MINIMUM WIDTH .............................................................................. 2 FT 4. SLABS ON GRADE SHALL BEAR ON APPROVED SUBGRADE PER THE RECOMMENDATIONS OF THE SOILS REPORT. 5. CONTRACTOR TO PROVIDE FOR DE-WATERING OF EXCAVATIONS FROM EITHER SURFACE WATER, GROUND WATER, OR SEEPAGE, IF REQUIRED. 6. CONTRACTOR SHALL PROVIDE FOR DESIGN AND INSTALLATION OF ALL CRIBBING, SHEATHING, AND SHORING REQUIRED AND SHALL BE SOLELY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES INCLUDING LAGGING, SHORING, AND PROTECTION OF ADJACENT PROPERTY, STRUCTURES, STREETS, AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL SAFETY ORDINANCES. 7. ALL EXCAVATIONS SHALL BE PROPERLY BACKFILLED. DO NOT PLACE BACKFILL BEHIND RETAINING WALLS BEFORE CONCRETE OR GROUT IN THE WALLS AND SLABS RESTRAINING THE WALLS HAVE ATTAINED FULL DESIGN STRENGTH. CONTRACTOR SHALL BRACE OR PROTECT ALL BUILDING AND PIT WALLS BELOW GRADE FROM LATERAL LOADS UNTIL ATTACHED FLOORS ARE COMPLETELY IN PLACE AND HAVE ATTAINED FULL STRENGTH. CONTRACTOR SHALL PROVIDE FOR DESIGN, PERMITS, AND INSTALLATION OF SUCH BRACING. 8. FOUNDATIONS SHALL BE PLACED AND ESTIMATED ACCORDING TO DEPTHS SHOWN ON DRAWINGS. SHOULD SOIL ENCOUNTERED AT THESE DEPTHS NOT BE APPROVED BY THE INSPECTOR OR SOILS ENGINEER, FOUNDATION ELEVATIONS WILL BE ALTERED . 9. FOOTING BACKFILL AND UTILITY TRENCH BACKFILL WITHIN BUILDING AREA SHALL BE MECHANICALLY COMPACTED IN LAYERS IN ACCORDANCE WITH THE SOILS REPORT AND APPROVED BY THE SPECIAL INSPECTOR. 10. ALL ABANDONED FOOTINGS, UTILITIES, ETC. SHALL BE REMOVED. SPECIAL INSPECTION 1. ALL SPECIAL INSPECTIONS AND TESTING SHALL BE IN CONFORMANCE WITH CHAPTER 17 OF THE CODE. THE OWNER IS RESPONSIBLE FOR RETAINING AN APPROVED AGENCY TO PERFORM SPECIAL INSPECTIONS FOR THIS PROJECT. 2. THE SPECIAL INSPECTION TABLES LISTED BELOW ARE PARTIAL EXCERPTS OF THE TABLES LISTED IN THE CODE AND ADDITIONAL SPECIAL INSPECTION REQUIREMENTS OF THIS PROJECT. IT IS THE RESPONSIBILITY OF THE SPECIAL INSPECTOR TO CONFORM WITH ALL ASPECTS OF OF THE CODE AND STANDARDS REFERENCED BY CHAPTER 17. 3. THE SPECIAL INSPECTORS MUST BE CERTIFIED BY THE GOVERNING JURISDICTION IN THE CATEGORY OF WORK REQUIRED TO HAVE SPECIAL INSPECTION. EXCEPTIONS: A. SOILS INSPECTIONS BY THE SOILS ENGINEER OF RECORD B. SMOKE CONTROL SYSTEM, BY THE MECHANICAL ENGINEER OF RECORD C. WHEN WAIVED BY THE GOVERNING JURISDICTION 4. THE CONSTRUCTION MATERIALS TESTING LABORATORY MUST BE APPROVED BY THE GOVERNING JURISDICTION FOR TESTING OF MATERIALS, SYSTEMS, COMPONENTS AND EQUIPMENTS. 5. THE SPECIAL INSPECTIONS IDENTIFIED ON PLANS ARE IN ADDITION TO, AND NOT A SUBSTITUTE FOR, THOSE INSPECTIONS REQUIRED TO BE PERFORMED BY THE GOVERNING JURISDICTION. SPECIALLY INSPECTED WORK WHICH IS INSTALLED OR COVERED WITHOUT THE APPROVAL OF AN INSPECTOR FROM THE GOVERNING JURISDICTION IS SUBJECT TO REMOVAL OR EXPOSURE. 6. FOR CONTINUOUS INSPECTION, WHEN WORK IN MORE THAN ONE CATEGORY OF WORK REQUIRING SPECIAL INSPECTION IS TO BE PERFORMED SIMULTANEOUSLY, OR THE GEOGRAPHIC LOCATION OF THE WORK IS SUCH THAT IT CANNOT BE CONTINUOUSLY OBSERVED IN ACCORDANCE WITH THE PROVISIONS OF THE CODE, IT IS THE AGENT'S RESPONSIBILITY TO EMPLOY A SUFFICIENT NUMBER OF INSPECTORS TO ASSURE THAT ALL WORK IS INSPECTED IN ACCORDANCE WITH THOSE PROVISIONS. 7. PERIODIC INSPECTION SHALL OCCUR FREQUENTLY ENOUGH TO INSPECT ALL OF THE INSTALLED ITEMS AND TO PERIODICALLY WITNESS THE INSTALLATION OF THE ITEMS. 8. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INFORM THE SPECIAL INSPECTOR OR INSPECTION AGENCY AT LEAST ONE WORKING DAY PRIOR TO PERFORMING ANY WORK THAT REQUIRES SPECIAL INSPECTION. ALL WORK PERFORMED WITHOUT REQUIRED SPECIAL INSPECTION IS SUBJECT TO REMOVAL. 9. THE SPECIAL INSPECTOR SHALL PROVIDE WEEKLY REPORTS AND A FINAL REPORT TO THE STRUCTURAL ENGINEER. 10. THE SPECIAL INSPECTOR SHALL ENSURE THAT ALL DEFICIENCIES RELATED TO THE SPECIAL INSPECTION TABLES NOTED BY THE STRUCTURAL ENGINEER IN STRUCTURAL OBSERVATION REPORTS ARE CORRECTED. SUCH COMPLIANCE SHALL BE REFERENCED IN SPECIAL INSPECTOR REPORT. 11. THE OWNER OR ENGINEER IN RESPONSIBLE CHARGE, ACTING AS OWNER'S AGENT, SHALL EMPLOY ONE OR MORE AGENCIES TO PERFORM CONTINUOUS INSPECTION OF THE WALL REPAIR DURING CONSTRUCTION SOIL: SPECIAL INSPECTION TASK CONTINUOUS PERIODIC 1. VERIFY MATERIAL BELOW FOOTINGS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. 2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. 3. PERFORM CLASSIFICATION AND TESTING OF CONTROLLED FILL MATERIALS. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND 4• COMPACTION OF CONTROLLED FILL. PRIOR TO PLACEMENT OF CONTROLLED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS 5• BEEN PREPARED PROPERLY. CONCRETE: SPECIAL INSPECTION TASK 1. INSPECTION OF REINFORCING STEEL, PRESTRESSING TENDONS, SHEAR STUDS, AND PLACEMENT. 2. INSPECION OF REINFORCING STEEL WELDING: A. VERIFICATION OF WELDABILITY OF REINFORCING STEEL OTHER THAN ASTM A706. B. REINFORCING STEEL RESISTING FLEXURAL AND AXIAL FORCES IN MOMENT FRAMIES, ANID BOUNDARY ELEMENTS OF SPECIAL REINFORCED CONCRETE SHEAR WALLS IN THE SFRS. C. SHEAR REINFORCEMENT. D. OTHER REINFORCING STEEL. INSPECTION OF BOLTS AND EMBED PLATES TO BE INSTALLED IN CONCRETE PRIOR TO AND DURING 3• PLACEMENT OF CONCRETE. 4. POST INSTALLED ANCHORS IN HARDENED CONCRETE MEMBERS (SEE KEYNOTE 1). 5. VERIFYING USE OF REQUIRED DESIGN MIX. AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE SPECIMENS FOR STRENGTH TESTS, 6• PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE. 7. INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES 8. MAINTENANCE OF THE SPECIFIED CURING TEMPERATURE AND TECHNIQUES 9. FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBERS BEING FORMED CONCRETE SPECIAL INSPECTION KEYNOTES: X X X X X CONTINUOUS PERIODIC X X X X X X X X X X X X 1. THE SPECIAL INSPECTOR FOR ADHESIVE ANCHORS SHALL VERIFY THE DRILLING OF ANY HOLES, THE CLEANLINESS OF THE HOLE, THE MOISTURE IN THE HOLE, MIXING THE ADHESIVE, THE BRAND OF ADHESIVE, AND THE PROPER MATERIAL FOR ASSEMBLY. MECHANICAL, ELECTRICAL AND PLUMBING ELEMENTS: SPECIAL INSPECTION TASK ELECTRICAL EQUIPMENT USED IN EMERGENCY OR STANDBY POWER SYSTEMS (AND ALL OTHERS 1 • IN SDC 'E' OR 'F'), AND THEIR ANCHORAGE. PIPING SYSTEMS, AND THEIR ASSOCIATED MECHANICAL UNITS, DESIGNED TO CARRY HAZARDOUS 2• MATERIALS FOR THEIR INSTALLATION AND ANCHORAGE. DUCTWORK DESIGNED TO CARRY HAZARDOUS MATERIALS FOR THEIR INSTALLATION AND 3• ANCHORAGE. VIBRATION ISOLATION SYSTEMS, WHERE THE CONSTRUCTION DOCUMENTS REQUIRE A NOMINAL 4. CLEARANCE OF 1/4" OR LESS BETWEEN THE EQUIPMENT SUPPORT FRAME AND RESTRAINT, FOR THEIR INSTALLATION AND ANCHORAGE . CONTINUOUS PERIODIC X X X X "DECLARATION OF RESPONSIBLE CHARGE" (SHEETS 7 -15) I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HAVE EXCERCISED RESPONSIBLE CHARGE OF THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARD. I UNDERSTAND THAT THE CHECK OF THE PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. KPFF CONSUL TING ENGINEERS FIRM 3131 CAMINO DEL RIO NORTH, SUITE 1080 ADDRESS SAN DIEGO, CA, 92108 CITY, STATE, ZIP 1080 CAMINO DEL RIO NORTH TELEPHONE AARON.PEBLEY@KPFF.COM EMAIL AARON PEBLEY S5383 09/30/2024 BY 8/03/2023 DATE R.C.E.# EXP.DATE SHEET LIST -SITE WALLS Sheet Number CS-001 CS-002 CS-100 CS-600 CS-700 CS-705 CS-706 CS-707 Sheet Name GENERAL STRUCTURAL NOTES GENERAL STRUCTURAL NOTES SITE WALL PARTIAL PLAN AREA A CONCRETE TYPICAL DETAILS MASONRY WALL TYPICAL DETAILS MASONRY RETAINING AND SITE WALLS MASONRY RETAINING AND SITE WALLS MASONRY RETAINING AND SITE WALLS "AS BUILT" RCE __ _ EXP. ___ _ REVIEWED BY.· INSPECTOR SHEET CS-001 DATE DATE 11. DO NOT DE-TENSION SOIL TIEBACKS UNTIL ALL ATTACHED SLABS. CLOSURE STRIPS AND PERPENDICULAR CONCRETE AND CMU WALLS ARE IN PLACE AND HAVE CURED. 12. REMOVE CONTAMINATED SOILS AS REQUIRED PER THE SOILS REPORT. f----+--+------------+---+-----+---+-------, I SH6ET I CITY OF CARSLBAD ~3 ENGINEERING DEPARTMENT l_____!U ~P::::R::::ff=l:::S[:::'.,GR'.::A::::D=IN::::G=P=LA=N::S=F,::::O::::R.=· ========::'....'.::==== 13. SOIL REMOVAL AND RECOMPACTION SHALL BE PER THE SOILS REPORT AND APPROVED CONTRACT DOCUMENTS. 14. ALL ROOF AND AREA DRAINAGE SHALL BE DIRECTED AWAY FROM FOUNDATIONS. 15. OUNDATION EXCAVATIONS SHALL BE CHECKED BY THE PROJECT GEOTECHNICAL ENGINEER PRIOR TO PLACING STEEL AND CONCRETE. l ~~ ~l'-QfESSJo-,,., <.-,,.Q -------......'"V. ◄ "'"" ¢i, /... Q .. -.... it ~. II "'-/)No53 \£ 3131 Camino Del Rio North 11 • Suite 1080 ,l •\J • - San Diego, CA 92108 ~/-----c,; ~ Tel 619.521.8500 Fax 619.521.859 ':i,./~ UcT"~~ ... KPFF PROJECT #2100173 Of' cACII' DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL JONIS CONFERENCE CENTER PEDESTRIAN/ ADA IMPROVEMENTS FOR IONIS LOTS 21/22 GENERAL STRUCTURAL NOTES GR2023-0009 APPROVED: JASON S. GELDERT ENGINEERING MANAGER RCE 63972 EXPIRES 9/30/24 DWN BY.· JPR CHKD BY.· __ _ RVWD BY.· PROJECT NO. SDP2021-0029 SDP2021-0029 DATE DRAWING ND. 540-7B Docusign Envelope ID: 566A09F6-B29F-4FA5-B4FC-7971AA550EDF 9/30/2024 NFNF ~ N N Cl) I C: lll 0.. 2 en ~ Ql -C: Ql C) ..... C: 0 C) .!!2 C: .Q SPECIAL INSPECTION {CONTINUED) ENGINEERING NOTE: THIS A VERY CONDENSED VERSION OF THE FULL STEEL INSPECTION TABLE; USE ON SMALL PROJECTS. MASONRY: SPECIAL INSPECTION TASK (LEVEL BJ PER ACI 530 TABLE 1.19.2 COMPLIANCE WITH REQUIRED INSPECTION PROVISIONS OF THE CONSTRUCTION DOCUMENTS AND 1 • THE APPROVED SUBMITTALS SHALL BE VERIFIED. 2. VERIFICATION OF fm PRIOR TO CONSTRUCTION EXCEPT WHERE SPECIFICALLY EXEMPTED BY CODE. VERIFICATION OF SLUMP FLOW AND VSI AS DELIVERED TO THE SITE FOR SELF-CONSOLIDATING 3• GROUT. 4. AT THE BEGINNING OF THE MASONRY CONSTRUCTION, THE FOLLOWING SHALL BE VERIFIED A. PROPORTIONS OF SITE PREPARED MORTAR. B. CONSTRUCTION OF MORTAR JOINTS C. LOCATION OF REINFORCEMENT, CONNECTORS, PRESTRESSING TENDONS AND ANCHORAGES. D. PRESTRESSING TECHNIQUE. 5. DURING CONSTRUCTION THE INSPECTION PROGRAM SHALL VERIFY A. SIZE AND LOCATION OF STRUCTURAL ELEMENTS B. TYPE, SIZE, AND LOCATION OF ANCHORS, INCLUDING OTHER DETAILS OF ANCHORAGE OF MASONRY TO STRUCTURAL MEMBERS, FRAMES OR OTHER CONSTRUCTION. C. SPECIFIED SIZE, GRADE, AND TYPE OF REINFORCEMENT D. WELDING OF REINFORCING BARS. E. PROTECTION OF MASONRY DURING COLD WEATHER (TEMPERATURE BELOW 40°) OR HOT WEATHER (TEMPERATURE ABOVE 90°) F. APPLICATION AND MEASUREMENT OF PRESTRESSING FORCE. 6. PRIOR TO GROUTING, THE FOLLOWING SHALL BE VERIFIED: A. GROUT SPACE IS CLEAN. B. PLACEMENT OF REINFORCEMENT, CONNECTORS, PRESTRESSING TENDONS AND ANCHORAGE. C. PROPORTIONS OF SITE-PREPARED GROUT AND PRESTRESSING GROUT FOR BONDED TENDONS D. CONSTRUCTION OF MORTAR JOINTS. GROUT PLACEMENT SHALL BE VERIFIED TO ENSURE COMPLIANCE WITH CODE AND CONSTRUCTION 7• DOCUMENT PROVISIONS. A. GROUTING OF PRESTRESSING BONDED TENDONS 8. PREPARATION OF ANY REQUIRED GROUT AND MORTAR SPECIMENS AND/OR PRISMS. 9. POST-INSTALLED ANCHORS (SEE KEYNOTE 1 ). MASONRY SPECIAL INSPECTION KEYNOTES: CONTINUOUS PERIODIC X X X -X -X -X X - -X X - -X X - -X X - -X -X -X -X X - X - X - -X 1. THE SPECIAL INSPECTOR FOR ADHESIVE ANCHORS SHALL VERIFY THE DRILLING OF ANY HOLES, THE CLEANLINESS OF THE HOLE, THE MOISTURE IN THE HOLE, MIXING THE ADHESIVE, THE BRAND OF ADHESIVE, AND THE PROPER MATERIAL FOR ASSEMBLY. (G.S.N. CONTINUED) CONCRETE 1. ALL CONCRETE CONSTRUCTION SHALL CONFORM WITH THE CODE AND WITH THE PROVISIONS OF ACI 318. 2. SCHEDULE OF STRUCTURAL CONCRETE PERFORMANCE REQUIREMENTS: 3. 4. 5. COMPRESSIVE MAX MAX MAX MEMBER STRENGTH DENSITY W/C SHRINKAGE 28DAY (PCF) RATIO (%) (NOTE 4) U.N.O. (PSI) ALL FOOTINGS 3000 150 0.5 0.060 ALL OTHER SUBSTRUCTURE 3000 150 0.5 0.060 WALLS, PIERS, PILES AND CAPS * LIMIT TOTAL WATER CONTENT TO A MAXIMUM OF 300#/C.Y •• ADDITIONAL TEST CYLINDERS ARE REQUIRED FOR 56 DAY STRENGTHS. CONCRETE MIXES: A. MIX SHALL BE DESIGNED BY A QUALIFIED TESTING LABORATORY AND APPROVED BY THE STRUCTURAL ENGINEER. B. MIX DESIGN METHODS (TEST HISTORY OR TRIAL BATCH METHOD) PER THE CODE SHALL BE USED TO PROPORTION CONCRETE. SUBMIT MIX DESIGN METHOD DATA FOR REVIEW. C. MIX DESIGNS SHALL SATISFY EITHER THE SHRINKAGE CRITERIA OR THE W/C RATIO AND TOTAL WATER CONTENT CRITERIA SPECIFIED. D. MIX DESIGNS FOR SLABS ON GRADE, ELEVATED SLABS AND BEAMS MUST MEET SHRINKAGE CRITERIA, REGARDLESS OF THE W/C RATIO SPECIFIED. E. MIX DESIGNS SHALL MEET THE MINIMUM REQUIREMENTS FOR EXPOSURE CATEGORIES F0, SO, WO, AND CO AS DEFINED IN CHAPTER 19 OF ACI 318 UNLESS OTHERWISE SPECIFIED IN THE TABLE ABOVE. F. FOR SHOTCRETE APPLICATIONS, PROVIDE MIX DESIGNS FOR COMPRESSIVE STRENGTH AS WELL AS TEST PANEL RESULTS FOR STRENGTH AND CORE GRADES PER THE SHOTCRETE GENERAL STRUCTURAL NOTES. G. PORTLAND CEMENT SHALL CONFORM TO ASTM C-150, TYPE I OR II, UNLESS NOTED OTHERWISE. H. AGGREGATE FOR HARDROCK CONCRETE SHALL CONFORM TO ALL REQUIREMENTS AND TESTS OF ASTM C33 AND PROJECT SPECIFICATIONS. EXCEPTIONS MAY BE USED ONLY WITH PERMISSION OF THE STRUCTURAL ENGINEER. I. AGGREGATE FOR LIGHTWEIGHT CONCRETE (MAX DENSITY< 120 PCF) SHALL BE THE EXPANDED SHALE TYPE CONFORMING TO ALL REQUIREMENTS AND TESTS OF ASTM C330 AND PROJECT SPECIFICATIONS. EXCEPTIONS MAY BE USED ONLY WITH PERMISSION OF THE STRUCTURAL ENGINEER. SHRINKAGE TESTS: A. CONCRETE SHRINKAGE FOR MIX DESIGNS SHALL BE DETERMINED AT 28 DAYS PERASTM C157. CONCRETE INSTALLATION: A. CONCRETE MIXING OPERATION, ETC. SHALL CONFORM TO ASTM C94. B. PLACEMENT OF CONCRETE SHALL CONFORM TO ACI 318 AND PROJECT SPECIFICATIONS. C. CLEAN AND ROUGHEN TO 1/4" AMPLITUDE ALL CONCRETE SURFACES AGAINST WHICH NEW CONCRETE ISTO BE PLACED. D. ALL REINFORCING BARS, ANCHOR BOLTS, AND OTHER CONCRETE INSERTS SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE. 6. PENETRATIONS IN CONCRETE: A. PROVIDE SLEEVES FOR PLUMBING AND ELECTRICAL OPENINGS IN CONCRETE BEFORE PLACING. DO NOT CUT ANY REINFORCING WHICH MAY CONFLICT. CORING CONCRETE IS NOT PERMITTED EXCEPT AS OUTLINED IN THE M.E.P. COORDINATION NOTES. OPENINGS, POCKETS, ETC., LARGER THAN 6" SHALL NOT BE PLACED IN CONCRETE SLABS, AT DROP PANELS OR BEAMS UNLESS SPECIALLY DETAILED ON THE STRUCTURAL DRAWINGS. NOTIFY STRUCTURAL ENGINEER WHEN DRAWINGS BY OTHERS SHOW OPENINGS, POCKETS, ETC. LARGER THAN 6" NOT SHOWN ON THE STRUCTURAL DRAWINGS, SEE THE M.E.P. COORDINATION NOTES FOR ADDITIONAL RESTRICTIONS ON THE PLACEMENT OF OPENINGS IN SLABS AND WALLS. B. PIPES LARGER THAN 1 1/2" DIAMETER SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE EXCEPT WHERE SPECIFICALLY APPROVED BY STRUCTURAL ENGINEER. PIPES SHALL NOT DISPLACE OR INTERRUPT REINFORCING BARS. PIPES SHALL NOT BE PLACED IN COLUMN DROP HEAD AREA OR STUDRAIL ZONE. SPACE EMBEDDED PIPES AT A MINIMUM OF 3 DIAMETERS. SIZE OF PIPE SHALL BE ONE THIRD OF SLAB THICKNESS MAX. SEE THE M.E.P. COORDINATION NOTES FOR ADDITIONAL RESTRICTIONS ON THE PLACEMENT OF PIPES IN STRUCTURAL CONCRETE. 7. CONCRETE FORMWORKAND SHORING: A. CONTRACTOR TO SUBMIT ENGINEERED SHORING AND RESHORING PLANS AND CALCULATIONS TO THE STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION. SEE SHOP DRAWING/SUBMITTALS AND CONSTRUCTION JOINTS NOTES FOR ADDITIONAL REQUIREMENTS. B. FOAM USED AS STAY-IN-PLACE FORMS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 5.8 PSI AT 1% DEFORMATION AND A MINIMUM COMPRESSIVE MODULUS OF 580 PSI PER ASTM D6817. C. PROVIDE 3/4" CHAMFER ON ALL EXPOSED CORNERS UNLESS INDICATED OTHERWISE BY THE ARCHITECT. 8. ALL EXTERIOR CRACKS TO BE SKIM COATED. 9. TOPPING SLABS AT EXTERIOR CONDITIONS OR EXPOSED TO VIEW: A. ADD FIBERMESH-300 TO THE MIX AT A DOSAGE OF 1.5#/cy B. MOISTEN THE SUBGRADE PRIOR TO POURING THE CONCRETE BUT AVOID STANDING WATER. C. DO NOT ADD WATER TO THE MIX AT THE JOB SITE. D. ADD TROWEL JOINTS AT EACH WAY SPACED AT 28*SLAB THICKNESS AND FULL DEPTH JOINTS EACH WAY SPACED 84*SLAB THICKNESS (EX: 7-0" OC AND 21'-0" OC FOR 3" SLAB). VERIFY LOCATIONS WITH ARCHITECT E. ADD #3 X 5'-0" MIDHEIGHT DIAGONAL BARS AT RE-ENTRANT CORNERS AND LARGE OPENINGS WHERE CRACKS ARE LIKELY TO FORM. F. MOIST CURE THE FINISHED SLAB FOR 7 DAYS. REINFORCING STEEL 1. BAR SPECIFICATIONS: 2. A. REINFORCING BARS SHALL CONFORM TO THE REQUIREMENTS OF CHAPTER 19 OF THE CODE, ASTM A615 (A706 WHERE NOTED ON PLANS), GRADE 60 U.N.O. B. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 AND SHALL BE SUPPORTED ON APPROVED CHAIRS. INSTALLATION: A. BARS SHALL BE CLEAN OF RUST, GREASE, OR OTHER MATERIALS LIKELY TO IMPAIR BOND. B. ALL REINFORCING BAR BENDS SHALL BE MADE COLD. C. ALL BARS SHALL BE MARKED SO THEIR IDENTIFICATION CAN BE MADE WHEN THE FINAL IN-PLACE INSPECTION IS MADE. D. BARS IN SLABS SHALL BE SECURELY SUPPORTED ON WELL-CURED CONCRETE BLOCKS OR APPROVED METAL CHAIRS, PRIOR TO PLACING CONCRETE. E. UNLESS SPECIFICALLY NOTED OTHERWISE: THE MINIMUM CLEAR SPACING BETWEEN PARALLEL BARS IN A LAYER SHALL BE AT LEAST db, BUT NOT LESS THAN 1 ". WHERE PARALLEL REINFORCEMENT IS PLACED IN TWO OR MORE LAYERS, THE UPPER LAYERS SHALL BE PLACED DIRECTLY ABOVE THE BARS IN THE BOTTOM LAYER WITH A CLEAR DISTANCE BETWEEN BARS NOT LESS THAN 1 ". 3. SPLICES: A. REINFORCING BAR SPLICES SHALL, IN CONCRETE, CONFORM TO THE PROVISIONS OF ACI 318, AND IN MASONRY, CONFORM TO THE PROVISIONS OF ACI 530. B. #14 AND #18 BARS SHALL NOT BE LAP SPLICED. C. LAP ALL HORIZONTAL BARS AT CORNERS AND INTERSECTIONS. D. DOWEL ALL VERTICAL REBAR TO FOUNDATIONS. E. ALL SPLICE LOCATIONS ARE SUBJECT TO APPROVAL BY STRUCTURAL ENGINEER. PROVIDE REQUIRED SHOP DRAWINGS AND FABRICATE AFTER ENGINEER'S REVIEW. F. MECHANICAL BAR SPLICES (COUPLERS) SHALL BE USED WHERE SPECIFIED ON PLANS. THEY MAY ALSO BE USED AT THE CONTRACTOR'S OPTION IN LIEU OF LAP SPLICES AND WHERE REINFORCING IS SHOWN CONTINUOUS THROUGH CONSTRUCTION JOINTS. THE MINIMUM COVER ON THE COUPLER OF 3/4" SHALL BE MAINTAINED. UNLESS NOTED OTHERWISE, ALL MECHANICAL BAR SPLICES SHALL BE "TYPE 2" AS DEFINED BY ACI 318 AND BE ONE OF THOSE LISTED BELOW AND INSTALLED PER THE MANUFACTURER'S RECOMMENDATIONS: • HRC 500 SERIES MECHANICAL COUPLERS (ICC ESR-2764) • LENTON A2 SERIES MECHANICAL SPLICES (IAPMO ER-0129) G. MINIMUM LAP SPLICES SHALL BE AS FOLLOWS: • WELDED WIRE FABRIC: 9" • DEFORMED BARS IN CONCRETE: 12" • DEFORMED BARS IN MASONRY: THE GREATER OF 24" OR 48 BAR DIA. 4. WELDING REBAR: A. WELDING OF REINFORCING MUST BE APPROVED BY THE STRUCTURAL ENGINEER. B. ALL WELDS SHALL BE IN CONFORMITY WITH THE PROJECT SPECIFICATIONS AND AWS D1 .4. SEE SPECIAL INSPECTION SECTION FOR WELDING INSPECTION REQUIREMENTS. C. ALL REINFORCING BARS TO BE WELDED SHALL BE ASTM A706, U.N.O. D. ALL WELDS SHALL BE DONE BY AWS CERTIFIED WELDERS USING THE FOLLOWING ELECTRODES, U.N.O: ASTMA706 E80XX ASTMA615 E90XX 5. REBAR DETAILING: A. REINFORCING STEEL SHALL BE DETAILED IN ACCORDANCE WITH ACI 315. B. COMPLETE AND DETAILED REINFORCING PLACEMENT DRAWINGS SHALL BE PREPARED AND SUBMITTED TO THE ARCHITECT FOR REVIEW BY THE STRUCTURAL ENGINEER PRIOR TO FABRICATION IN ACCORDANCE WITH SPECIFICATIONS AND APPLICABLE CODES. THESE APPROVED DRAWINGS SHALL BE AVAILABLE ON THE JOB SITE PRIOR TO PLACING OF CONCRETE. C. REBAR SPACINGS GIVEN ARE MAXIMUM ON CENTER WHETHER STATED AS "O.C." OR NOT. UNLESS A SPECIFIED LENGTH IS GIVEN, ALL REBAR IS CONTINUOUS WHETHER STATED AS "CONT." OR NOT. 6. MILL TEST REPORTS SHALL BE SUBMITTED PRIOR TO PLACEMENT OF CONCRETE. 7. CONTINUOUS INSPECTION OF CONCRETE SHALL INCLUDE INSPECTION DURING INSTALLATION OF REINFORCING STEEL. INSPECTION SHALL BE SCHEDULED SO THAT PLACEMENT OF REINFORCING STEEL, CONDUIT, SLEEVES, AND EMBEDDED ITEMS MAY BE CORRECTED PRIOR TO PLACEMENT OF OVERLYING GRIDS OF REINFORCING STEEL. 8. CONCRETE PROTECTION FOR REINFORCEMENT: (i) CAST-IN-PLACE CONCRETE (NON-PRESTRESSED). THE FOLLOWING CONCRETE COVER SHALL BE PROVIDED FOR REINFORCEMENT, U.N.O.: A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH B. CONCRETE EXPOSED TO EARTH OR WEATHER: NO. 6 THROUGH NO. 18 BAR NO. 5 BAR, W31 OR D31 WIRE AND SMALLER C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND: SLABS, WALLS, JOISTS: NO. 14AND NO. 18 BAR NO. 11 BAR AND SMALLER BEAMS, COLUMNS: PRIMARY REINFORCEMENT, TIES, STIRRUPS AND SPIRALS SHELLS, FOLDED PLATE MEMBERS: NO. 6 BAR AND LARGER NO. 5 BAR, W31 OR D31 WIRE AND SMALLER MINIMUM COVER 3" 2" 1 1/2" 1 1/2" 3/4" 1 1/2" 3/4" 1/2" TOLERANCES +OR- 3/8" 3/8" 3/8" 3/8" 1/4" 3/8" 1/4" 3/16" CONSTRUCTION JOINTS 1. ALL CONSTRUCTION JOINTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH ACI 318 SECTION 6.4 AND THE TYPICAL CONSTRUCTION JOINT DETAILS SHOWN ON THE STRUCTURAL DRAWINGS. 2. ALL SURFACES OF CONSTRUCTION JOINTS SHALL BE CLEANED TO REMOVE DUST, CHIPS, OR OTHER FOREIGN AND ROUGHENED TO 1/4" MINIMUM AMPLITUDE (UNLESS KEYWAYS ARE PROVIDED PER DETAILS ON THE STRUCTURAL DRAWINGS) PRIOR TO PLACING ADJACENT CONCRETE. 3. THE CONTRACTOR SHALL SUBMIT THE PROPOSED LOCATIONS OF CONSTRUCTION JOINTS FOR APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER BEFORE STARTING CONSTRUCTION. 4. SLAB POUR STRIPS SHALL BE POURED NO SOONER THAN 28 DAYS AFTER YOUNGEST ADJACENT CONCRETE, U.N.O. THE SLAB BAY THAT INCLUDES THE POUR STRIP SHALL BE SHORED FOR THE FULL HEIGHT OF THE STRUCTURE. ADJACENT BAYS ON EITHER SIDE OF THE POUR STRIP SHALL BE SHORED UNTIL THE POUR STRIP IS POURED AND REACHES 75% OF DESIGN STRENGTH, U.N.O. 5. SEE REINFORCING STEEL NOTE 3 FOR MECHANICAL SPLICES. 6. AT SLABS-ON-GRADE, TOPPING SLABS, AND WALLS, DO NOT PLACE CONCRETE IN LENGTHS EXCEEDING 100 FEET. 7. CAST SLABS-ON-GRADE IN ALTERNATE SECTIONS UNLESS PERMANENT FORMS ARE USED. WAIT 48 HOURS BETWEEN ALL ADJACENT CONCRETE CASTINGS. MASONRY 1. ALL MASONRY CONSTRUCTION SHALL CONFORM WITH THE CODE AND WITH THE PROVISIONS OF TMS 402 AND TMS 602. 2. CONCRETE BLOCK SHALL BE ASTM C90 HOLLOW LOAD-BEARING CONCRETE MASONRY UNITS CONFORMING TO CODE SECTION 2103.1, MEDIUM WEIGHT DOUBLE OPEN END UNITS WITH A MAXIMUM LINEAR SHRINKAGE OF 0.065%. 3. MORTAR SHALL BE ASTM C270 TYPE 'M' OR'S' CONFORMING TO CODE SECTION 2103.2 4. GROUT SHALL BE ASTM C476 COMFORMING WITH CODE SECTION 2103.3 5. ALL CELLS SHALL BE GROUTED SOLID, U.N.O. 6. MINIMUM STRENGTH REQUIREMENTS: UNIT STRENGTH BLOCK STRENGTH GROUT STRENGTH fm (psi) (psi) (psi) NOTES 2,000 2,000 2,500 2,500 3,250 3,000 WHERE NOTED ON PLANS 7. COMPLIANCE WITH COMPRESSIVE STRENGTH REQUIREMENTS SHALL BE DETERMINED USING UNIT STRENGTH METHOD OR PRISM TESTING PER CODE SECTION 2105. 8. REINFORCING BARS -PROVIDE 1/2" CLEAR BETWEEN REINFORCING AND WALL OF MASONRY UNITS. SEE NOTES UNDER REINFORCING STEEL FOR ADDITIONAL REQUIREMENTS. 9. VERTICAL BARS IN WALLS ARE TO BE PLACED IN CENTER OF CELLS UNLESS OTHERWISE SHOWN. VERTICAL BARS ARE TO BE TIED OR OTHERWISE FIXED INTO POSITION PRIOR TO GROUTING WITH WIRE POSITIONERS OR OTHER SUITABLE DEVICES AT INTERVALS NOT EXCEEDING 200 BAR DIAMETERS. 10. VERTICAL BARS IN WALLS AND PILASTERS SHALL HAVE DOWELS OF EQUAL SIZE AND SPACING IN ALL FOOTINGS. DOWELS TO BE FIELD CHECKED BY THE MASONRY CONTRACTOR BEFORE PLACEMENT OF CONCRETE. 11. HORIZONTAL BARS SHALL BE PLACED IN BOND BEAM BLOCKS. 12. NO MORE THAN TWO BARS SHALL BE PLACED IN ANY ONE CELL. WHERE PLAN CALLS FOR MORE THAN TWO, DIVIDE EQUALLY AMONG ADJACENT CELLS. 13. WHEN MULTIPLE BARS ARE LAPPED IN A CELL, LAP REBAR 65 BAR DIAMETERS MIN. AND STAGGER LAPS 24 IN. U.N.O. 14. PIPES OR CONDUITS SHALL NOT BE EMBEDDED IN ANY MASONRY UNLESS SPECIFICALLY DETAILED ON THE APPROVED STRUCTURAL DRAWINGS. NOTIFY ENGINEER WHERE OTHERS SHOW PIPES OR CONDUITS EMBEDDED IN MASONRY THAT ARE NOT SHOWN ON THE APPROVED STRUCTURAL DRAWINGS. 15. SEE DRAWINGS FOR LOCATIONS OF MASONRY CONTROL JOINTS, (MCJ). CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 25 FEET. 16. HORIZONTAL CONTROL JOINTS SHALL BE FORMED BY STOPPING THE GROUT POUR NOT LESS THAN 1/2", NOR MORE THAN 2" BELOW THE TOP OF THE UPPER MOST UNIT GROUTED. HORIZONTAL REINFORCEMENT SHALL BE FULLY EMBEDDED IN GROUT. SHEET CS-002 "AS BUILT" RC£ __ _ EXP. ___ _ DATE REVIEWED BY.· INSPEC TDR DATE I---+--+------------+--+--+--+--I SH?ET I CITY OF CARSLBAD ~3 ENGINEERING DEPARTMENT l_____!U ::P::R::1:,:::C l::S[=:'.,GR,'::A::D::IN::G=P::LA=N::S=F,::O::R_=. =========-===== l ~~ .!!2 ~l'-QfESSJo-,,., C: <.-,,.Q --.........."'f( 0 ◄ "'"" ¢i, -~ Q :::, " """' 1 • 1 • !!J AARON ~ ~ 1 ■ ~/) :aE7r253 i 0 3131 Camino Del Rio North '-' • -"' Suite 1080 ll .-" •- DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL JONIS CONFERENCE CENTER PEDESTRIAN/ ADA IMPROVEMENTS FOR IONIS LOTS 21/22 GENERAL STRUCTURAL NOTES GR2023-0009 SDP2021-0029 APPROVED: JASON S. GELDERT ENGINEERING MANAGER RCE 63972 EXPIRES 9/30/24 DA TE DWN BY.· JPR CHKD BY.· __ _ PROJECT NO. SDP2021-0029 DRAWING ND. 540-7B g:J San Diego, CA 92108 ~,s,/---=~~ "" -o Tel 619.521.8500 Fax 619.521.859 "I;,-/~ UcTIJ'D'c,~"" .8 KPFF PROJECT #2100173 Of' cACII' ~L _________________________________________________ ..,:::::~_....:;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;~;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;:;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;:;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;:;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;.J OTHER APPROVAL CITY APPROVAL RVWD BY.· 10/12/20231:19:38 PM Docusign Envelope ID: 566A09F6-B29F-4FA5-B4FC-7971AA550EDF 9/30/2024 NFNF I I \ \ \ \ \ \ \ ' \ \ \ \ \ \ \ \ \ I I I I I I I I I I I I I I I I I I I I I I I I I I \ I I \ \ \ \ I I \ \ '-\ 1 \ I \ ' I I I \ \ I \ \ I \ I \ I I I \ I \ I I I I I I I I I I I I I I I I I I I I I \ \ \ \ \ \ \ \ / / \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ I \ \ I I \ \ \ \ \ I \ \ \ \ \ \ \ \ \ PEDESTRIAN BRIDGE ABUTMENT FOUNDATION BY OTHERS'' • / ,,, ,,, I I I \ \ \ I I \ !tJ ,,, \ \ \ \ \ \ \ \ ,,, \ \ \ \ \ I I I I \ \ \ I I \ I I I I I I I I \ I \ I I I \ \ \ \ \ \ \ \ \ \ I I \ \ \ \ \ \ \ I I \ \ \ \ I \ \ \ \ \ \ \ \ ---- ("' \ I I \ \ \ I I I \ I I I I I I I I I \ \ \ \ I I I I I I ( \ \ \ \ I \ I I I I \ I I I \ \ ---\ I I I I I I I I ,,, I -I ,.- I I I \ I \ I I I I \ I I \ I I I I I I I I I I I I I -------------- -------------- ~ .. . ' . \ \ I I I I \ I \ I \ I I I \ I \ \ \ I -------------- ---/ ------------ ) _/ I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I \ I SHEET CS-100 ~ ~ NOTE: CIVIL ENGINEER OF RECORD TO CONFIRM ALL TOP OF FOOTINGS (T.O.F.) ELEVATIONS "AS BUILT" (I) C) ..... C: 8 .!!2 C: .Q FOUNDATION NOTES: 1. SEE GENERAL NOTES AND TYPICAL DETAILS FOR INFORMATION NOT REFERENCED. TYPICAL DETAILS SHALL BE FOLLOWED WHERE APPLICABLE, WHETHER OR NOT REFERENCED ON PLAN. 2. SEE CIVIL DRAWINGS FOR: a. FINISHED GRADE ELEVATIONS -~ b. TOP OF WALL ELEVATIONS o c. WALL PROFILES PLAN LEGEND: T.O.W. ~ /+X'-X" T.O.FTG ~ /+X'-X" TOP OF WALL ELEVATION RELATIVE TO MSL. TOP OF WALL ELEVATIONS PROVIDED FOR REFERENCE ONLY. EXACT TOP OF WALLS ARE PER CIVIL DRAWINGS. TOP OF FOOTING ELEVATION RELATIVE TO MSL ::::: d. DESIGN FOR PAVEMENT FLATWORK, CURBS AND WALLS i1 RETAINING LESS THAN 3'-0" OF SOIL [/ 7 7 7 / 7 7 I FULLY GROUTED MASONRY WALL PER SECTIONS o e. TOP OF FOOTING ELEVATIONS WHERE NOT SHOWN ~ ~ ~ 3131 Camino Del Rio North gJ 3. PROVIDE CONTROL JOINTS AT EVERY 100'-0" PER 5 S-- - - - - - - -s FOOTING STEP PER 8 Suite 1 o5o -o CS-700 CS-600 San Diego, CA 92108 _g '----' '----' Tel 619.521.8500 Fax 619.521.859 DATE INITIAL DATE INITIAL DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RC£ ___ EXP.____ DATE REVIEWED BY.· INSPEC TDR DATE I SHBET I CITY OF CARSLBAD rn ENGINEERING DEPARTMENT 3 PRtCIS[ GRADING PLANS FOR: JONIS CONFERENCE CENTER PEDESTRIAN/ ADA IMPROVEMENTS FOR IONIS LOTS 21/22 SITE WALL PARTIAL PLAN AREA A GR2023-0009 SDP2021-0029 APPROVED: JASON S. GELDERT ENGINEERING MANAGER RCE 63972 EXPIRES 9/30/24 DATE DWN BY.· JPR PROJECT NO. DRAWING ND. CHKD BY.· SDP2021-0029 540-7B RVWD BY.· :, KPFF PROJECT #2100173 <( ~~~~~~'."'."':"" _________________________________________________________________ ...::;:::;:::.... __ ~;;;;;;;;;;;;;;;;;;;;;;;;~;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;~;;;;;;;;;;;;;;;;;;;;;;;;~~;;;;;;;;;;;;;;;;;;;;;;;;;;,'.;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;,J 10/12/20231:19:39 PM Docusign Envelope ID: 566A09F6-B29F-4FA5-B4FC-7971AA550EDF 9/30/2024 NFNF ~ ~ (I) C) ..... C: 8 . !!2 C: .Q .!!2 C: 0 ::::: i1 0 0 -"' ti) (I) s ~ 1 5 .0 .c CASE 1* -BAR CENTER TO CENTER SPACING> 6" (NORMAL WEIGHT, GRADE 60, UNCOATED) BAR SIZE D #3 1 1/2" CONCRETE CLEAR BAR SIZE ---#3 #4 #5 #6 #7 STRENGTH COVER (IN) (PSI) LAP CLASS--Ld LAP Ld LAP Ld LAP Ld LAP Ld LAP 90' HOOK #4 2" #5 2 1/2" TOP 1 '-1" 1'-5" 1'-6" 2•-on 1'-10" 2'-5" 2'-2" 2'-10" 3'-7" 4'-8" 1.50 BOTTOM 1'-0" 1'-4" 1'-2" 1'-7n 1'-5" 1'-11" 1'-8" 2'-2" 2'-9" 3'-7" TIES & STIRRUPS HOOKS ONLY 2.00 TOP 1 '-1" 1'-5" 1'-6" 2'-0" 1'-10" 2'-5" 2'-2" 2'-10" 3'-2" 4'-2" BOTTOM 1'-0" 1'-4" 1'-2" 1'-7" 1'-5" 1'-11 11 11-811 2'-2" 2'-5" 3'-2" .0 I 12 2MAX TOP 1 '-1" 1'-5" 1'-6" 2'-0" 1'-10" 2'-5" 2'-2" 2'-10" 3'-2" 4'-2" 3.00 BOTTOM 1'-0" 1'-4" 1'-2" 1'-7" 1'-5" 1'-11" 1'-8" 2'-2" 2'-5" 3'-2" TOP 1'-0" 1.50 1'-4" 1'-3" 1'-8" 1'-7" 2'-1" 1'-11" 2'-6" 3'-1" 4'-1" BOTTOM 1'-0" 1'-4" 1'-0" 1'-4" 1'-3" 1'-8" 1'-6" 2'-0" 2'-5" 3'-2" TYPICAL BAR OFFSET TOP 4000 2.00 1'-0" 1'-4" 1'-3" 1'-8" 1'-7" 2'-1" 1'-11" 2'-6" 2'-9" 3'-7" BOTTOM 1'-0" 1'-4" 1'-0" 1'-4" 1'-3" 1'-8" 1'-6" 2'-0" 2'-1" 2'-9" .0 TOP 1'-0" 1'-4" 1'-3" 1'-8" 1'-7" 2'-1" 1'-11" 2'-6" 2'-9" 3'-7" 3.00 BOTTOM 1'-0" 1'-4" 1'-0" 1'-4" 1'-3" 1'-8" 1'-6" 2'-0" 2'-1" 2'-9" 1 4db 1 Jl BAR SIZE D #3THRU#8 6db 2§N #9 THRU #11 8db CASE 1 KEYNOTES: 180' HOOK 90' HOOK #14 THRU #18 10db 1. IF THE DIMENSIONS SHOWN ON FIGURE 1 ARE NOT MET, REBAR DEVELOPMENT AND LAP SPLICE LENGTHS SHALL BE PER THE CASE 2 SCHEDULE. 2. INCREASE DEVELOPMENT AND SPLICE LENGTHS FOR EACH OF THE FOLLOWING CONDITIONS WHEN THEY OCCUR: STANDARD HOOKS A. fy > 60 KSI: MULTIPLY LENGTH BY fy/60 B. EPOXY COATED REBAR: MULTIPLY LENGTH BY 1.2 C. LIGHTWEIGHT CONCRETE: MULTIPLY LENGTH BY 1.33 REINFORCING BAR BENDING DETAIL SCALE: 1"= 1'-0" NOTES: 1. INCREASE EMBED DEPTH FOR EACH OF THE FOLLOWING CONDITIONS WHEN THEY OCCUR: A. fy > 60 KSI: MULTIPLY LENGTH BY fy/60 B. EPOXY COATED REBAR: MULTIPLY LENGTH BY 1.2 C. LIGHTWEIGHT CONCRETE: MULTIPLY LENGTH BY 1.33 CONCRETE STRENGTH psi 3000 4000 6000 CONCRETE STRENGTH psi 3000 4000 6000 HEADED REINFORCEMENT #3 0'-7" 0'-6" 0'-6" #3 0'-9" 0'-8" 0'-6" PER PLAN AND G.S.N. ~ #4 0'-9" 0'-8" 0'-7" #4 0'-11" 0'-10" 0'-8" ~ -- #5 0'-11" 0'-10" 0'-8" #5 1'-2" 1'-0" 0'-10" I - --I - HEADED BAR EMBED, Ldt #6 #7 #8 1'-2" 1'-4" 1'-6" 1'-0" 1'-2" 1'-4" 0'-10" 0'-11" 1'-1" HOOKED BAR EMBED, Ldh #6 #7 #8 1'-5" 1'-8" 1'-10" 1'-3" 1'-5" 1'-7" 1'-0" 1'-2" 1'-4" I w ...J w ! ...J '.§ al .c i:': 0::: ::I w 0::: ~ a. w a. V ' /, #9 #10 1'-8" 1 '-11" 1'-6" 1'-8" 1'-2" 1'-4" #9 #10 2'-1" 2'-4" 1 ·-1 o· 2'-1" 1'-6" 1'-8" ~ ,,,,,--STANDARD HOOK #11 2'-1" 1'-10" 1'-6" #11 2'-7" 2'-3" 1'-10" CASE 2* -ALL OTHER BAR SPACING (NORMAL WEIGHT, GRADE 60, UNCOATED) BAR DESCRIPTION CONCRETE BAR SIZE ---#3 #4 #5 #6 #7 AND LOCATION IN STRENGTH STRUCTURE (PSI) LAP CLASS--Ld LAP Ld LAP Ld LAP Ld LAP Ld LAP BAR SPACING >2x'd,' & TOP 1'-10" 2'-5" 2'-5" 3'-2" 3'-0" 3'-11" 3'-7" 4'-8" 5'-3" 6'-10" CLEAR COVER > 'd,' 3000 OR BOTTOM 1'-5" 1'-10" 1'-10" 2'-5" 2'-4" 3'-1" 2'-9" 3'-7" 4'-0" 5'-3" BEAM & COLUMN TOP 1'-7" 2'-1" 2'-1" 2'-9" 2'-7" 3'-5" 3'-1" 4'-1" 4'-6" 5'-11" BAR SPCING > 'd,' & 4000 CLEAR COVER > 'd,' BOTTOM 1'-3" 1'-8" 1'-7" 2'-1" 2'-0" 2'-8" 2'-5" 3'-2" 3'-6" 4'-7" TOP 2'-9" 3'-7" 3'-7" 4'-8" 4'-6" 5'-11" 5'-5" 7'-1" 7'-10" 10'-3" 3000 BOTTOM 2'-1" 2'-9" 2'-9" 3'-7" 3'-6" 4'-7" 4'-2" 5'-5" 6'-0" 7'-1 O" OTHER CASES TOP 4000 2'-4" 3'-1" 3'-1" 4'-1" 3'-11 II 5'-2" 4'-8" 6'-1" 6'-9" 8'-10" BOTTOM 1'-10" 2'-5" 2'-5" 3'-2" 3'-0" 3'-11" 3'-7" 4'-8" 5'-3" 6'-10" CASE 2 KEYNOTES: 1. INCREASE DEVELOPMENT AND SPLICE LENGTHS FOR EACH OF THE FOLLOWING CONDITIONS WHEN THEY OCCUR: A. fy > 60 KSI: MULTIPLY LENGTH BY fy/60 B. EPOXY COATED REBAR: MULTIPLY LENGTH BY 1.2 C. LIGHTWEIGHT CONCRETE: MULTIPLY LENGTH BY 1.33 HOOKED AND HEADED REBAR EMBEDMENT REBAR DEVELOPMENT LENGTHS AND LAP SPLICES SCALE: 1"= 1'-0" MIN CLEAR SPACING= 1 1" PIPE WRAP OR SPACE AROUND PIPE, TYP --~ 2x LARGER PIPE DIA PIPE THRU FTG, PLACE ABOVE MAIN REINF FTG REINF A 6"MIN J'------JL-TY P ELEVATION SCALE: 1" = 1 '-0" WALL ABOVE WHERE OCCURS SLAB ON GRADE OR EXTERIOR HARDSCAPE WHERE OCCURS SEE NOTE 4 WHERE PENETRATIONS OCCUR IN WALL ABOVE 1'-6" MIN T.O.F. 1==1 ----=111 ·w_......._._.,. __ ...._..._ ....... ,,_,;1 ,----r -1 I PVC OR C.I. SLEEVE z I w/ INNER DIA= PIPE :a; Ii:: 0.D. PLUS 2", ~ ~ SEENOTE3-----1-~b i~~~~~~~~~-"<- OPTIONAL CONST JOINT z. 8 u.. z :a; ~ CONCRETE FILL (SAME WIDTH AS FOOTING AND FULL LENGTH OF TRENCH). PLACE FILL AROUND SLEEVES BEFORE FOOTING IS POURED NOTES: ' -., -,' ', -. - ---;;:--.,.,.------,_,----_------,_ r,:\ SECTION 0,_;1--=~~~-- - , ' I 1L 2 TRENCH FOR PIPE PARALLEL TO FTG SHALL BE LOCATED SO THAT FTG WILL NOT BE UNDERMINED GROUND LINE BACKFILL PER SPECS NO EXCAVATION ALLOWED BELOW THIS LINE 1. PIPE SHALL NOT PASS THROUGH OR BE PLACED UNDER COLUMN FOOTING. 2. FOR PIPES MORE THAN 3'-0" BELOW BOTTOM OF FOOTING, TRENCH MAY BE BACKFILLED WITH CONTROLLED, COMPACTED FILL PER SPECIFICATIONS OR LEAN CONCRETE. 3. PIPES LARGER THAN 6" O.D. SHALL NOT PASS THROUGH FOOTINGS WITHOUT BEING SPECIFICALLY DETAILED ON THESE PLANS OR APPROVED BY THE ENGINEER OF RECORD. 3131 Camino Del Rio North Suite 1080 San Diego, CA 92108 NOTES: 1. TENSION DEVELOPMENT LENGTHS AND TENSION LAP SPLICES ARE CALCULATED PER ACI 318-14, SECTION 25.4 AND 25.5, RESPECTIVELY. 2. THESE TABLES ARE BASED ON UNCOATED GRADE 60 REBAR PLACED IN NORMAL WEIGHT CONCRETE. SEE KEYNOTES BELOW THE TABLES FOR ADJUSTMENTS TO TABLE VALUES. 3. THIS SCHEDULE IS NOT APPLICABLE TO DUCTILE MOMENT FRAME MEMBERS RESISTING SEISMIC FORCES. 4. ALL SPLICE LENGTHS SHALL BE PER "LAP" LENGTHS PER TABLE UNLESS NOTED OTHERWISE ON PLANS. 5. WHERE "CLASS A" SPLICE IS CALLED OUT ON PLANS, USE TENSION DEVELOPMENT LENGTHS "Ld" PER TABLE. 6. TOP BARS ARE HORIZONTAL SLAB, BEAM & FOOTING BARS WITH MORE THAN 12 IN. OF CONCRETE CAST BELOW THE BARS AND ALL HORIZONTAL WALL REINFORCEMENT. 7. BOTTOM BARS ARE ALL VERTICAL WALL REINFORCEMENT AND ALL HORIZONTAL SLAB BEAM & FOOTING BARS WITH LESS THAN 12" OF CONCRETE CAST BELOW THE BAR. 8. COVER DESIGNATES CLEAR COVER FROM SPLICED BAR TO FACE OF MEMBER. SPACING DESIGNATES CENTER-TO-CENTER SPACING OF SPLICED BARS. 9. FOR NON-CONTACT LAP SPLICES, ADD THE DISTANCE BETWEEN THE BARS TO THE SPLICE LENGTH IN THE ABOVE TABLE. 10. WHEN BARS OF DIFFERENT SIZES ARE LAP SPLICED, SPLICE LENGTH SHALL BE THE LARGER OF "Ld" OF THE LARGER BAR OR THE "LAP" LENGTH OF THE SMALLER BAR. 11. WHERE #14 OR #18 REBAR IS CALLED OUT ON PLAN, USE TYPE 2 COUPLERS PER GSN. TENSION DEVELOPMENT LENGTH TYPICAL LAP SPLICE ~ NON-CONTACT LAP SPLICE ~ [I) C'c-- , ,e----,f-_CENTER TO CENTER (C-C) SPACING, 6" MIN FIG. 1 Ld PER TABLE A ' LAP PER TABLE A ' LAP+ 'S' FIG. 2 DATE INITIAL ,. , -~ -CONCRETE JOINT 4 8 TYPICAL PIPE PENETRATIONS AT FOOTINGS 4. FOR PENETRATIONS IN STRUCTURAL WALL ABOVE (CMU OR CONCRETE) PROVIDE SLEEVE, SIMILAR AT FOOTING PENETRATION. WATERPROOFING OF PENETRATION BY OTHERS . Tel 619.521.8500 Fax 619.521.859 KPFF PROJECT #2100173 ENGINEER OF WORK REVISION DESCRIPTION NO SCALE L , L , L , . ' ~ ~ ~ I"-'"-HORIZ REINF TURNED VERT ~FOOTING/ A A V ' CORNER INTERSECTION NOTE: 1. L=30db OR 1 '-6" MINIMUM TYPICAL FOUNDATION INTERSECTIONS SCALE: 3/4" = 1 '-0" TOPOFFTG (SEE PLAN) □ [I) [I) REBARS TO MATCH FOOTING REINF SIZE AND SPACING (2 BARS MIN) LAP PER GD ------- D 2'S' MIN ~ cJ' • <I A V OPTIONAL CORNER ...J [I) [I) p SEE PLAN FOR FOOTING REINF -~ LAPPERQ) '----' NOTES: 1. D = DEPTH OF FOOTING 2. S = 1'-6" MAX, U.N.0. TYPICAL STEPPED FOOTING DETAIL SCALE: 1"= 1'-0" SHEET CS-600 "AS BUILT" RC£ EXP . DATE REVIEWED BY.· INSPEC TDR DATE I SHgET I CITY OF CARSLBAD rn ENGINEERING DEPARTMENT 3 PRtCIS[ GRADING PLANS FOR: JONIS CONFERENCE CENTER PEDESTRIAN/ ADA IMPROVEMENTS FOR IONIS LOTS 21/22 CONCRETE TYPICAL DETAILS GR2023-0009 SDP2021-0029 APPROVED: JASON S. GELDERT ENGINEERING MANAGER RCE 63972 EXPIRES 9/30/24 DATE DWN BY.· JPR PROJECT NO. DRAWING ND. DATE INITIAL DATE INITIAL CHKD BY.· SDP2021-0029 540-7B OTHER APPROVAL CITY APPROVAL RVWD BY.· ...._. _______________________________________________________________________________________________________________________________________________________ __, 10/12/20231:19:40 PM Docusign Envelope ID: 566A09F6-B29F-4FA5-B4FC-7971AA550EDF 9/30/2024 NFNF ~ ~ (I) C) ..... C: 8 . !!2 C: .Q .!!2 C: 0 ::::: i1 0 0 -"' ti) (I) s ~ 1 MASONRY REINFORCING BAR DEVELOPMENT & LAP SPLICE LENGTH. (INCHES) FOR CMU STRENGTH fm = 2000 PSI NOTES: NOMINAL BAR MINIMUM TRANSVERSE REINFORCING BAR SIZE 1. COVER s BAR SPACING ASSUMED. COVER IS DISTANCE FROM OUTSIDE FACE OF BLOCK TO EDGE OF BAR. BLOCK LOCATION COVER REBAR SIZE (SEE NOTE 5) #3 #4 #5 #6 NO 16 22 35 54 EACH FACE OR 2" STAGGERED YES 16 18 23 27 8" NO 16 16 23 44 CENTERED 3 1/4" YES 16 16 23 27 NO 16 22 35 54 EACH FACE OR 2" STAGGERED YES 16 18 23 27 10" NO 16 16 18 33 CENTERED 4 1/4" YES 16 16 18 27 NO 16 22 35 54 EACH FACE OR 2" STAGGERED YES 16 18 23 27 12" NO 16 16 16 26 CENTERED 5 1/4" YES 16 16 16 26 TYPICAL REINFORCING LAP SPLICE FOR MASONRY WALLS SCALE: 1"= 1'-0" NOTES: 1. SEE PLAN FOR LOCATION. 2. STACKED BLOCK AT JOINT FROM FOUNDATION TO TOP OF WALL. WATER PROOFING 1" COMPRESSIBLE JT MATERIAL AND SEALANT PER SPECS BOUNDARY REINF PER-/- PER ARCH'L DWG'S \ ~1-11-· 1 __________ ~ _ _ _ 1llJJffi=-=1===rr-Jlffi~IJ_ I_ WATERSTOP BELOW GRADE STOP REINF AT JOINTS -111=111-. L I ===11 EU El ll=-11 _L_ LJ :i I I 0 11 µi-::~--;T BOUNDARY ol~ -REINF PER-/- C l m= -I c-- AT CORNERS CONTROL JOINT IN MASONRY RETAINING WALL SCALE: 1" = 1 '-0" MIN CLEAR SPACING= 2x LARGER PIPE DIA PIPE THRU FTG, PLACE ABOVE MAIN REINF FTG REINF -1 I I •.· • • : _··-•. : _·•· ·• .... • • ._. '. ..•.. • .. •·-·• . : : : ::;, ~ -I I ••• : ..... ;: : '.: ·.•· •• >. > : : : , • .. : "' 1 •• .• .-.•.·.· ·.-._·.· ... -, ',· -. -' -, . A WALL ABOVE WHERE OCCURS OPTIONAL CONST JOINT I f-a.. w 0 (.!) b z ' 5 0 LL #7 #8 63 72 32 72 61 72 32 51 63 72 32 71 45 72 32 38 63 72 32 71 36 55 32 36 2. BARS SPLICED BY NON-CONTACT LAP SPLICES SHALL BE SPACED A DISTANCE APART NOT GREATER THAN 1/5 THE REQUIRED LENGTH OF THE LAP SPLICE OR MORE THAN 8". 3. #9 AND LARGER BARS SHALL BE SPLICED BY WELDING OR BY APPROVED MECHANICAL CONNECTORS THAT CAN DEVELOP 125% OF THE SPECIFIED BAR STRENGTH IN TENSION. 4. WHEN ADJACENT LAP SPLICES ARE SEPARATED BY 3" OR LESS, THE REQUIRED LAP LENGTH SHALL BE INCREASED BY 30%. 5. PROVIDE TRANSVERSE REINFORCEMENT AT BOTH ENDS OF LAP SPLICES AS SHOWN IN THE FIGURE BELOW IN ORDER TO USE THE REDUCED LAP SPLICE LENGTH. LAP PER SCHEDULE 1/2" MIN 8" MAXTYP SEE NOTE 5 +-~--,,-a: a: <( w w > d~-......................... _.,._ •. ,....... .............. +<-............................. .........,.._.__._-+-.............. -+-~ WHERE REBAR ISAT EACH FACE, STAGGER LAP SPLICE LOCATIONS CMUWALL& REBAR PER PLAN CONDUIT BY OTHERS ( 1 1/2"0 MAX) --~ NOTES: . . ' . . . __ . -_......:... ~-_,_, ,-;-""T'"-...... ....,...- TRANSVERSE REINF WHERE OCCURS 1. WHEREVER POSSIBLE, PLACE CONDUITS IN UNREINFORCED CELLS. 2. WHEN CONDUITS MUST BE PLACED IN THE SAME CELL AS REBAR, SEE DETAIL ABOVE. 3. CONDUITS SHALL NOT BE RUN HORIZONTALLY IN WALLS. 4. NO CONDUITS ARE ALLOWED WHERE TOW BARS ARE IN A CELL. 5. 'D' SHALL BE BASED ON THE LARGER DIAMETER OF THE TWO CONDUIT SIZES. TYPICAL VERTICAL CONDUITS IN CMU WALLS SCALE: 1"= 1'-0" SLAB ON GRADE OR EXTERIOR HARDSCAPE WHERE OCCURS PVC OR C.I. SLEEVE w/ INNER DIA= PIPE 0.D. PLUS2", SEE NOTE 4 WHERE PENETRATIONS OCCUR IN WALL ABOVE 1'-6" MIN ~ -=I 11 w----1..J..L..J---LL.1.---l..J.il,..---'-T--1 I z ::;; io SEE NOTE 3 ----+---it- ,-+-:tt.:::::.....=..-=-=--=:......!t.~----"s- z :;;; io ... , co z ··.·:.,•.·· ;;;; _-, ~ ·....:....··_;_ .__:; -'--- =I I I - , ' I 1L 2 TRENCH FOR PIPE PARALLEL TO FTG SHALL BE LOCATED SO THAT FTG WILL NOT BE UNDERMINED GROUND LINE BACKFILL PER SPECS 1 1" PIPE WRAP OR SPACE AROUND PIPE, TYP --~ ·, ' : CONCRETE FILL (SAME WIDTH AS FOOTING AND FULL LENGTH OF TRENCH). PLACE FILL AROUND SLEEVES BEFORE FOOTING IS POURED ----· _-,--_'--,-----,_ ,------;. : ,, , . , r.\ SECTION 0)>---- NO EXCAVATION ALLOWED BELOW THIS LINE 6"MIN k--+-TYP ELEVATION TYPICAL PIPE PENETRATIONS AT FOOTINGS SCALE: 1"= 1'-0" NOTES: 1. PIPE SHALL NOT PASS THROUGH OR BE PLACED UNDER COLUMN FOOTING. 2. FOR PIPES MORE THAN 3'-0" BELOW BOTTOM OF FOOTING, TRENCH MAY BE BACKFILLED WITH CONTROLLED, COMPACTED FILL PER SPECIFICATIONS OR LEAN CONCRETE. 3. PIPES LARGER THAN 6" 0.D. SHALL NOT PASS THROUGH FOOTINGS WITHOUT BEING SPECIFICALLY DETAILED ON THESE PLANS OR APPROVED BY THE ENGINEER OF RECORD. 4. FOR PENETRATIONS IN STRUCTURAL WALL ABOVE (CMU OR CONCRETE) PROVIDE SLEEVE, SIMILAR AT FOOTING PENETRATION. WATERPROOFING OF PENETRATION BY OTHERS. 3 (2)#4 VERT MIN STD 90° HOOKTYP / • ,f --< / / (2)#4 VERT MIN ~ / ~i.. / ,-1 (2) #4 VERT MIN---..__ STD 90° HOOKAND AL TERNA TE --< / -, / / / / / / ' l, V A • V· ·v I. ' / G~·/ ' I/ / / .. ""'. ' . r/ . '. :-/ .:•,: 1·· / ' . ·; / , / •. .. • / A V INTERSECTION / / / / / / .. .. / / / / / ~ / / r,," PLAN-10" OR 12" CMU / . ... , / CORNER BART 0 TEEL~ MATCH HORIZ s / / / / .. .. .. ' -u· .• / / / / PLAN 8" CMU / ,/ / / ' .,,. / / / , ~ / . , , / '. / CORNER TYP CMU WALL INTERSECTIONS AND CORNERS SCALE: 1" = 1 '-0" CONT HORIZ BAR OR MIN #4x2'-0" CTR'D ON BOLT _ _,,,. . , HORIZEMBED PER SCHEDULE DRYPACKOR GROUT--_,,, CHORD BARS ~ PER PLAN, (2) • \ #5MIN --~ a: 0 Cl) _J z f-(.) => _J _OQ ;..-0:: tll -+..._,II,-'-+-<( MIN WALL THICKNESS PER SCHEDULE MIN WALL THICKNESS PER SCHEDULE MINIMUM EMBEDMENT LENGTH STD 90° HOOKTYP (3) #4 VERT MIN r (2)#4 TYP . D.. ::s z ::;; ' w 0--' w => Cl□ :a: w wI f-(.) a: Cl) w a: >W D.. BOLT SIZE0 HORIZ EMBED VERT EMBED MINIMUM WALL THICKNESS 1/2" 4" 6" 6" 5/8" 5" 7" 8" 3/4" 6" 8" 8" 7/8" 7" 9" 10" 1" 8" 10" 12" TYPICAL BOLT EMBEDMENT IN CMU WALLS SCALE: 1" = 1 '-0" 3131 Camino Del Rio North Suite 1080 San Diego, CA 92108 Tel 619.521.8500 Fax 619.521.859 KPFF PROJECT #2100173 DATE INITIAL ENGINEER OF WORK 8 REVISION DESCRIPTION REINF PER PLAN SEE ARCH (2) #4 MIN ---~ 48d LAP SLOPED TOP OF WALL CHORD BAR LOCATED BELOW TOP OF WALL SLOPED CHORD REINFORCING AT TOP OF WALL SCALE: 1 " = 1 '-0" D/A 810 D/A 811 D/A812 NOTE: WIRE POSITIONERS SHALL BE PLACED NO MORE THAN 200 BAR DIAMETERS APART. VERTICAL BAR POSITIONER SCALE: 1" = 1 '-0" SHEET CS-700 "AS BUILT" RC£ EXP . DATE REVIEWED BY.· INSPEC TDR DATE CT[:] CITY OF CARSLBAD rn 0 ENGINEERING DEPARTMENT 3 PRtCIS[ GRADING PLANS FOR: JONIS CONFERENCE CENTER PEDESTRIAN/ ADA IMPROVEMENTS FOR IONIS LOTS 21/22 MASONRY WALL TYPICAL DETAILS GR2023-0009 SDP2021-0029 APPROVED: JASON S. GELDERT ENGINEERING MANAGER RCE 63972 EXPIRES 9/30/24 DATE DWN BY.· JPR PROJECT NO. DRAWING ND. DATE INITIAL DATE INITIAL CHKD BY.· SDP2021-0029 540-7B OTHER APPROVAL CITY APPROVAL RVWD BY.· ----------------------------------------------------------------------------------------------------------------------------------------------------------' 10/12/20231:19:41 PM Docusign Envelope ID: 566A09F6-B29F-4FA5-B4FC-7971AA550EDF 9/30/2024 NFNF ~ ~ (I) C) ..... C: 8 . !!2 C: .Q .!!2 C: 0 ::::: i1 0 0 -"' ti) (I) s ~ SLOPE GRADE WHERE OCCURS #4 DOWEL@ 18", 18 .. 1 CNTR'D IN WALL "t" +24" AND SLAB, TYP --..__ ADD'L (2)#4x2'-0" @8" CENTR'D ON GAURDRAIL POSTS(CONTRACTOR TO COORD w/POST LOCATIONS) ----- CMU WALL PER PLAN #4@24", TYP REBAR PER ELEVATION ----- 1 0" CMU, FULLY GROUTED WALL SHERE OCCURS PER SCHEDULE, TYPE 1 LAP PER t-:c-=-s--=-10:-::t-----,_ -.____,, #6@12" #6@12" 7' -0" MIN PER SOILS REPORT SECTION BRIDGE RAMP SCALE: 3/8" = 1 '-0" GUARDRAIL PER ARCHITECT WHERE OCCURS HARDSCAPE PER CIVIL I ii 3131 Camino Del Rio North Suite 1080 San Diego, CA 92108 GUARDRAIL PER ARCHITECT WHERE OCCURS SOIL OVER TOP OF FOAM, 1 '-0" MIN, w/ MIRAFI 140N FILTER FABRIC BARRIER PERGEOTECH T.O.W. ~ • ~R CIVIL GEOFOAM PER NOTE 7 OF CONCRETE NOTES, SEE SHEET CS-002 (FILL VOIDS w/ PEA GRAVEL) 8" CMU, FULLY GROUTED WALL, REINF PER SCHEDULE DRAINAGE REQUIREMENTS PERG"J '\IJTYP FINISH GRADE PER CIVIL FOUNDATION PER PLAN, SEE PLAN FOR FOOTING STEPPERfa\ ~ ...._.., NOTES: 1. BOTTOM 3'-0" OF WALL SEGMENT SHALL BE 10" CMU, FULLY GROUTED WHERE NOTED ON PLAN. DATE INITIAL Tel 619.521.8500 Fax 619.521.859 KPFF PROJECT #2100173 ENGINEER OF WORK REVISION DESCRIPTION H t 3'-011 8" 4'-011 8" 5'-0" 8" 6'-0" 8" 7'-0" 8" 8'-011 8" 9'-0" 10" #4@24" @8" WALL #5@24"@10" WALL T.O.W. PER CIVIL ADD'L (2)#4x2'-0" @8" CENTR'D ON GAURDRAIL POSTS(CONTRACTOR TO COORD w/POST w 2'-011 2'-011 2'-6" 3'-0" 3'-6" 4'-0" 4'-6" SCHEDULE D 1511 1511 15" 18" 20" 20" 20" "F1" (3) #5 (3) #5 (3) #5 (4) #5 (5) #5 (6) #5 (7) #5 "F2" "O" Ld BARS #4@12" #4@24" 33" #4@12" #4@24" 33" #4@12" #4@24" 33" #5@12" #5@24" 41" #5@12" #5@8" 41" #6@12" #6@16" 49" #6@12" #6@16" 49" .,.-,---GUARDRAIL PER ARCHITECT WHERE OCCURS 2 3/4" TO ~ BAR r FLATWORK _j __ WHERE OCCURS ~~~-~-~ ---------7 -111-=---------------J I _,---"0"BAR LOCATIONS) ----:=_-:=_-:=_~;,---,fttrtt--f-K-~-SEEffiFOR DRAINAGE REQUIREMENTS SLOPE WHERE OCCURS--~ TOP OF GRADE OR BOTTOM OF BIOFIL TRATION I BASIN---~ TOP OF FOOTING PER CIVIL U.N.0. • <O Cl'. UJ > 0 0 () M #4CONT "t" 3" 6" 0 0 "0"BAR w WATERPROOFING AND DRAINAGE PER ffi "F2" BAR "F1" BAR Cl'. UJ 0.. :g MASONRY RETAINING WALL 1 :1 BACKSLOPE SCALE:N.T.S. SHEET CS-705 "AS BUILT" RC£ EXP . DATE REVIEWED BY.· INSPEC TDR DATE CTY:J CITY OF CARSLBAD rn 1 ENGINEERING DEPARTMENT 3 PRtCIS[ GRADING PLANS FOR: JONIS CONFERENCE CENTER PEDESTRIAN/ ADA IMPROVEMENTS FOR IONIS LOTS 21/22 MASONRY RETAINING AND SITE WALLS GR2023-0009 SDP2021-0029 APPROVED: JASON S. GELDERT ENGINEERING MANAGER RCE 63972 EXPIRES 9/30/24 DATE DWN BY.· JPR PROJECT NO. DRAWING ND. DATE INITIAL DATE INITIAL CHKD BY.· SDP2021-0029 540-7B OTHER APPROVAL CITY APPROVAL RVWD BY.· ------------------------------------------------------------------------------------------------------------------------------------------------10/12/20231:19:41 PM Docusign Envelope ID: 566A09F6-B29F-4FA5-B4FC-7971AA550EDF 9/30/2024 NFNF ~ ~ (I) C) 'E 0 C) "' ·c .Q 10/12/20231:19:42 PM #4@16" #5@16" DOWEL BAR HARDSCAPE SLAB BEYOND #5@16" DOWEL BAR #4@16" #8@16" DOWEL BAR 3131 Camino Del Rio North Suite 1080 San Diego, CA 92108 Tel 619.521.8500 Fax 619.521.859 KPFF PROJECT #2100173 Q ~l'-QfESSJo~ ~ AARON PEB No. 53 WALL JOG, SEE PLAN NOTES: 1 SEE GENERAL NOTES AND TYPICAL DETAILS FOR INFORMATION • NOT REFERENCED. TYPICAL DETAILS SHALL BE FOLLOWED WHERE APPLICABLE, WHETHER OR NOT REFERENCED ON PLAN. 2 SEE CIVIL DRAWINGS FOR: • a. FINISHED GRADE ELEVATIONS b. TOP OF WALL ELEVATIONS c WALL PROFILES ED ON CS d: TOP OF FOOTING ELEVATIONS WHERE NOT INDICAT SHEETS. ~ 3. PROVIDE CONTROL JOINTS AT EVERY 100'-0" PER ~ 8" CMU, FULLY GROUTED WALL PER PLAN ..._____, / PREFAB BRIDGE / _ _J BY OTHERS ' '--_:--:, ... ,,7 -- - - - - - - - FINISHED GRADE PER CIVIL, TYP PEDESTRIAN BRIDGE ABUTMENT BY OTHERS SHEET CS-706 "AS BUILT" RC£___ EXP. __ _ DATE REVIEWED BY.· INSPEC TDR DATE ~ CITY OF CARSLBAD ~ tt====E===t==========================~====i===jt===j==== L__23_J ENGINEERING DEPARTMENT l_____!U PRtCIIONIS CONFERENCE CENTER PEDESTRIAN/ ADA IMPROVEMENTS FOR IONIS LOTS 21/22 MASONRY RETAINING AND SITE WALLS GR202J-0009 SDP2021-0029 APPROVED: JASON S. GELDERT tt====E===t==========================~====i===jt===j==== I IE~NG~IN~ET~Rl~NG~M~A~NA~GE~R~RC~E~6~39~72~EX~Pl~RE~S~9/=J=0/724~~D~A~TE~f ;= JPR PROJECT NO. ORA WING ND. DWN BY.· DATE INITIAL DATE INITIAL DATE INITIAL CHKD BY.·__ SDP2021-0029 540-7B RVWD BY.· ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL Docusign Envelope ID: 566A09F6-B29F-4FA5-B4FC-7971AA550EDF 9/30/2024 NFNF ~ ~ (I) C) ..... C: 8 . !!2 C: .Q ' ~ ~ a a ~ ~ (I) ,:;; en -a 0 C) ' .!!2 C: 0 ::::: i1 0 0 -"' ti) (I) s ~ HARDSCAPE SLAB BEYOND SEEDETAI@ FOR STEP BAR TYP WALL ELEVATION SCALE: 3/8" = 1 '-0" #4@24"TYP WALL JOG, SEE PLAN BOTTOM 3'-0" OF WALL TO BE 10" THICK CMU 3131 Camino Del Rio North Suite 1080 San Diego, CA 92108 Tel 619.521.8500 Fax 619.521.859 KPFF PROJECT #2100173 DATE INITIAL ENGINEER OF WORK 8" CMU, FULLY GROUTED WALL PER PLAN .. d ' ~ ,'_ ' -;-.. • ·,11 .. ' ,_ \· :. ¥ .. , ,.,. ... DATE INITIAL REVISION DESCRIPTION OTHER APPROVAL NOTES: 1. SEE GENERAL NOTES AND TYPICAL DETAILS FOR INFORMATION NOT REFERENCED. TYPICAL DETAILS SHALL BE FOLLOWED WHERE APPLICABLE, WHETHER OR NOT REFERENCED ON PLAN. 2. SEE CIVIL DRAWINGS FOR: a. FINISHED GRADE ELEVATIONS b. TOP OF WALL ELEVATIONS c. WALL PROFILES d. TOP OF FOOTING ELEVATIONS WHERE NOT INDICATED ON CS SHEETS. 3. PROVIDE CONTROL JOINTS AT EVERY 100'-0" PER 0 PEDESTRIAN BRIDGE ABUTMENT BY OTHERS --------- SHEET CS-707 "AS BUILT" RC£ EXP . DATE REVIEWED BY.· INSPEC TDR DATE CT[:] CITY OF CARSLBAD rn 3 ENGINEERING DEPARTMENT 3 PRtCIS[ GRADING PLANS FOR: JONIS CONFERENCE CENTER PEDESTRIAN/ ADA IMPROVEMENTS FOR IONIS LOTS 21/22 MASONRY RETAINING AND SITE WALLS GR2023-0009 SDP2021-0029 APPROVED: JASON S. GELDERT ENGINEERING MANAGER RCE 63972 EXPIRES 9/30/24 DATE DWN BY.· JPR PROJECT NO. DRAWING ND. DATE INITIAL CHKD BY.· SDP2021-0029 540-7B CITY APPROVAL RVWD BY.· -----------------------------------------------------------------------------------------------------------------------------------------10/12/20231:19:42 PM Docusign Envelope ID: 566A09F6-B29F-4FA5-B4FC-7971AA550EDF 9/30/2024