Loading...
HomeMy WebLinkAboutPS 2021-0037; CORCORAN GLOBAL LIVING; Sign Permits/Programs (PS)( Cicyof Carlsbad MAY 1 S 2021 REVIEW FOR SIGN PERMIT P-11 PLANNING AP Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov REC'D BY -t-:-~~~""':-~.......,.......,.>.b"'-:!/\---- DATE ___,,q....~1-±-~~1--------- Cll Y Of--CA!·.,LSBAD PLAl~i-..JIHG DIVISION SIGN FEE ...L.,d:=b~•~,£...._ _______ _ SIGN PROGRAM FEE ________ _ RECEIPT NO. ------------ All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE . ..:.T.:.:.he=a:c.c.:.:.li c::.:a::.:t~io~n:..:m=.=u.:.st.:..b::.;e:..:.s.::.u b::.;m:.:.:.:.:itt:.:;:e::.::d::..c.::.:.:.::...=:....:.:..::.:...c..:-· m~. Average processing ti me: 2 weeks Name of Project: _....::L::....LJ_(:....C.::.....::.0....:.✓..=.>,""--'--''=-"-+=:::__-""""'"-'1L...:.....a=· "'=+---------.---,---=--- Address of Project: Ck 9c:2oo9 Assessor Parcel Number: ------------------------ Related Planning Case Number(S): ___________________ _ TYPE OF DEVELOPMENT: (a) Residential (d) ~ Commercial (e) Yc) Office/Industrial (f) Hotel/Motel Service Station Prof. Care (g) Theater (h) Gov't/Church/School (i) Public Park U) Produce Stand (k) Nursery (I) P-U/OS Zone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA YesJRJ NoD Specific Plan Number ____ _ VILLAGE REVIEW AREA (If yes. please complete information on page 3) YesB SOUTH CARLSBAD COASTAL REVIEW AREA Yes Notzl No~ SIGN ORDINANCE: Yes 0 COASTAL ZONE: Yes 0 P-11 No~ NocyJ Page 1 of 4 Rev. 10/13 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wall l <~o.~.~ ~ Suspended/Projecting Directional Canopy . '\ . Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes O No O Date ______ _ PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER SIGN SIGN SIGN ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT Pole** Monument** Wall I \ ~().~1~ 9-~ ,20,~55 b 5~' "'J { Suspended/Projecting I Directional Canopy Freestanding** (Project Identity) Digital Display PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Construction** For Sale** Banner Interim **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right- of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2 of 4 Rev. 10/13 SITE PLAN REQUIREMENT FOR POLE., MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to 'be approved over the counter. Additional time will be required for on-site inspection. I I I 3 I M .Sipl~~ / I ! I I I , ___ j si..w ,Clh<b &-o11 an, ---: . . I I I I Sliawallpr-,atrliau I PfL : I I :/ I -"'Jiu i : ----------~--- SipVwliility S1notN-(1) (i) I I N-6 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage:_ .. f~-f~iCJiiJ(O~o~·t-=-J°3~;-= sq. ft. Total Building Street Frontage: -~ ;:Jc l S,., linear fl Total SignageAllowance: <a2>,~5 sq. fl Existing Signage (sq. ft): C:::: ;2.<' ,'2 5 sq. ft. Remaining Sign Allowance at Present sq. ft. Proposed Signage (sq. ft.): < 2'l> • "Z3 sq. ft. Remaining Sign Allowance After Proposed Sign: sq. ft. VILLAGE REVIEW AREA Total Signable Area: ________ sq. fl Total Signable Area Length: sq. ft. Total Signable Area Height sq. ft. Total Projection from Wall Face: inches P-11 Poga 3 ol 4 Rev. 10f13 ID PROPERTY OWNER APPLICANT NAME PRINT OR TYP NAME PRINT OR TYPE MAILING ADDRESS MAILING ADDRESS ~q s y'Yl (4 v-¥'7 tl\11 ~ CITY TELEPHONE CITY STATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER ANO THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF KNOWLEDGE. DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. DATE 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: ❖ In right-of.way ❖ In visibility triangle at comer 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: Q. IA J \ b leMZAJ?Aa Date: $/\~ }Q__J P-11 Page4 or 4 Rev. 10/13 -.X: c.m 4 4Z4 Le& -mw::=a W..C$.AC!..W -M ICWC :::Ll Cabinet Sign with Push-Thru Lettering & LED Illumination Wall to be patched & painted by either PM or Meacor Signs. If completed by Meacor Signs, paint brand, color & finish must be provided by Tenant or PM. PAGE 1 SIGNS NOTE: DIGITAL RENDERING. COLORS, AND FINISHES ARE SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. COLORS AND FINISHES ARE NOT TO BE USED AS SAMPLES OF ACTUAL PAINT AND/OR MATERIAL FINISH. ACTUAL SIGNS WILL CONFORM TO SCALED DIMENSIONS. EXISTIN CURTIS WYLIE 10039 PROSPECT AVE., SUITE J SANTEE CA 92071 PHONE: 619-562-6001 FAX: 619-562-6088 E-MAIL: MEACOR@SBCGLOBAL.NET -~o , -oo"- SIGN PERMIT NO. PS 2>0 :z..\-003,7 D Y DATE BUILDING ~-~RO PO s ED CORCORAN 7670 EL C AMINO R EAL# 102 CARLSBAD, CA 92009 BRANDEN COBB PH: 310-622-5511 BRANDEN .C OBB@CORC O RANGL.COM " Channel Lettering & LED Illumination Dimensions & Material Line 1 = 14.25" Height Bar = 2.00" Height Line 2 = 5.75" Height Line 1 = 5.00" Depth Bar= 3.00" Depth Line 2 = 3.00" Depth .04" Thick Pre-Fabricated Aluminum Channel Returns with Painted Finish (Black) 1" Jewelite Trim Cap Edges (Black) with Retaining Screws .1875" Plex Faces with 3m Day / Night Vinyl (Appears Black During Daytime & Lights White During Night) 0.63" Thick Aluminum Backing Total SqFt: = 20.65 PAGE2 SIGNS NOTE: DIGITAL RENDERING, COLORS, AND FINISHES ARE SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. COLORS AND FINISHES ARE NOT TO BE USED AS SAMPLES OF ACTUAL PAINT AND/OR MATERIAL FINISH. ACTUAL SIGNS WILL CONFORM TO SCALED DIMENSIONS. 85in C 85in I 63.63 in I {GLOBAL LIVING CURTIS WYLIE 10039 PROSPECT AVE., SUITE J SANTEE CA 920 71 CORCORAN PHONE: 619-562-6001 FAX: 619-562-6088 7670 E L C AMINO REAL# 102 CARLSBA D , CA 92009 E-MAIL: MEACOR@SBCGLOBAL.NET E FRONT SIGNAGE • CARLSBAD PH: 310-622-5511 BRA NDEN.COBB@CORCORAN GL.C OM Cabinet Sign with Push-Thru Lettering & LED Illumination (Electrical) 12vSloanLED Power Supply 60 Watt 12VDC Modular Dry/Damp Rated 100-277VAC Input 701507-60Cl 110 Modules MAX LOAD Per 60w Power Supply PAGE3 SIGNS .050" THK. PRE-FABRICATED ALUMINUM CHANNEL L 5" DP. J 1 RETURNSl RETURNS WITH PAINTED FINISH-----------, 3/4" JEWELITE TRIM CAP EDGES WITH RETAINING SCREWS ------~ ~=-=-r+-----RIGID METALLIC CONDUIT(SEAL ALL WALL PENETRATIONS) 1/8" THK. PLEX FACES WITH FIRST-SURFACE APPLIED TRANSLUCENT VINYL OVERLAYS------~ r---1/2" FLEXIBLE METAL CONDUIT GROUND WIRF---------ft--17'tdJ~~~~~ .080" THK. ALUMINUM BACK\or--++----------i~ LOW VOLTAGE LED MODULE'i----tt---~ STAINLESS STEEL MOUNTING ..-------ll-l-----+'lll SCREWS (AS PER WALL CONSTRUCTION)---~ 114• DRAIN HOLE WITH LIGHT j BAFFLE----------' CURTIS WYLIE 10039 PROSPECT AVE., SUITE J SANTEE CA 92071 PHONE: 619-562-6001 FAX: 619-562-6088 E-MAIL: MEACOR@SBCGLOBAL.NET --LOW VOLTAGE i TRANSFORMER I ! HOUSING i [r.-<3 -DISCONNECT I ---~-SWITCH ~-JUNCTION BOX VOLTAGE IN 120v ++--TO ELECTRICAL J-BOX CORCORAN 7670 EL CAMINO REAL# 102 CARLSBADt CA 92009 NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND PROPER BONDING OF THE SIGN. 20 AMP DEDICATED CIRCUIT(S) WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR ALL INSTALLATIONS. E FRONT SIGNAGE -CARLSBAD BRANDEN COBB PH: 31 0-622-5511 BRANDEN.COBB@CORCORANGL.COM f .. I I I I \ \ \ \ \ I I \ I \ I I \ I ·r \ I I I I I I I I I I I I I I I I \ I I I I I I \ I I \ \ \ I \ I I I I I I ! .fuc1u4 &won ... ---------------------------- • • •• • ' ', • I e I• MCANIII.OCIII\DIIW (ICUANIIJ ,._ MllJ (ff• , .. ,, A • q- ~ .Wf 111 HI H 111 HHJ <I-... ~1 1 UI I H 111 l O, sniHIHIID • - ~THIii~ I I I