Loading...
HomeMy WebLinkAboutPS 2021-0042; QUIDEL; Sign Permits/Programs (PS)( Cicyof Carlsbad REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov PLANNING APPLICATI REcr--• 'ED REC'D sY.~a...=;~:,......._ii,,t.Ll~~~-- DATE t:,l ~J!e>) \ JUN I S 2021 SIGN FEE'"''Z _________ _ SIGN PRORAM FEE CIT'r Or-•..,A ,LSBAO RECEIPT NO. --------- PLA1,' I ·'., -)1\/1 NOTE: AN APPOINTMENT TS ~EQ 'f;'lt, FOR SUBMITTAL. PLEASE CONTACT THE APPOINTMENT SPECIALIST AT (760) 602· 2723 TO SCHEDULE AN APPOINTMENT. •SAME DAY APPOINTMENTS ARE NOT AVAILABLE* All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. Average processing time: 2 weeks Name of Project: _____ a_u_ld_e_i ____________________ _ Address of Project: ___ 2_2s_s_R_u_t_he_rf_o_rd_Rd_c_ar_1s_b_ad _______________ _ Assessor Parcel Number: ____ 2_1_2_os_2_o_so_o _________________ _ Related Planning Case Number(S): ____________________ _ TYPE OF DEVELOPMENT: Jal Residential (d) Hotel/Motel (g) (.{£)) Commercial (e) Service Station (h) (c) Office/Industrial (f) Prof. Care (i) SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Theater Gov't/Church/School Public Park U) Produce Stand (k) Nursery (I) P-U/0S Zone YesisL No D Specific Plan Number ____ _ VILLAGE REVIEW AREA (If ves, please complete information on page 3) Yes D SOUTH CARLSBAD COASTAL REVIEW AREA Yes 0 No □ No □ SIGN ORDINANCE: Yes~ No O COASTAL ZONE: Yes O No 0 P-11 Page 1 of 4 Rev. 02/28/18 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole 0 Monument 0 Wall Di Suspended/Projecting 0 Directional 0 Canopy 0 Freestanding (Project Identity) 0 PERMITS ISSUED FOR EXISTING SIGNS: Yes O No O Date -------- PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Pole** Monument** Wall \ \ 50 49.65 36" 34• Suspended/Projecting , Directional 2 2 Jd t; ~b 3y' (.,I ~-z~ Canopy -/ ( Freestanding** (Project Identity) Digital Display PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Construction** For Sale** Banner Interim **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of- way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2 of 4 Rev. 02/28/18 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I PII. / Sipt Dist~ce Requirement / I Show buildina/1 ; j r I / I '\ __ -../ __ ~how setbacks from all CW'bs ' . Show all property lines P/l. ' : ' : ' : : / :/ curb line : i -----------~--- Sipt Visibility 21.41.080 Sign design standards I Street N ame(s) I I (i) North Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: ___ sq. ft. T Id S F ~ /'~ ,, ft otal Bui ing treet rontage: 1 ~ linear . Total Signage Allowance:, i, 11 -sq. ft. Existing Signage (sq. ft.): /J 4 sq. ft. Remaining Sign Allowance at Present: (} /lh • sq . ft. o.zJ, I 6 Proposed Signage (sq. ft.): ____ ,_-1_r.? ____ sq . ft. Remaining Sign Allowance After Proposed Sign: sq. ft. VILLAGE REVIEW AREA Total Signable Area: _________ sq. ft. Total Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: inches P-11 Page 3 of 4 Rev. 02/28/18 PROPERTY OWNER APPLICANT NAME (PRINT OR TYPE) NAME (PRINT OR TYPE) ARE SD Region No. 71, LLC AKC Permit Services MAILING ADDRESS MAILING ADDRESS 10996 Torreyana Rd. STE 250, 15197 Lighthouse Lane San Diego, CA 92121 Lake Elsinore, CA 92530 CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE Steve Pomerenke Kasey Clark 858-354-3995 951-471-8419 I CERTIFY THAT I AM THE LEGAL OWNER I CERTIFY THAT I AM THE REPRESENTATIVE AND THAT ALL THE ABOVE INFORMATION OF THE LEGAL OWNER AND THAT ALL THE IS TRUE AND CORRECT TO THE BEST OF ABOVE INFORMATION IS TRUE AND CORRECT MY KNOWLEDGE. ~ OF MY KNOWLEDGE. ~~ ~-~-.Lt -(, . j --z._o z...,j SIGNATURE DATE SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: ❖ In right-of-way ❖ In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. APPROVED: Planner:_-~ Date: 6/lb/WU 6. When approved r~u~te c p~ to ta Ent V' P-11 Page 4 of 4 Rev. 02/28118 Carlsbad Research Center June 8, 2021 Mr. Glen Bayliff ARE-SD REGION NO. 71, LLC 10996 Torreyanna Road, Suite 250 San Diego, CA 92121 Re: Lot 16 -QUID EL Signs Review Dear Mr. Bayliff, Architectural Review Committee The Architectural Review Committee (ARC) of the Carlsbad Research Center (CRC) has reviewed your application for a sign review submitted on behalf of your tenant, QUID EL, for your building located at 2285 Rutherford Road on lot 16 of the CRC. The plans are proposing a single tenant identification wall sign on the North elevation of your building facing Rutherford Road, identified as sign 'A' on the submitted plans. The sign will include the "Quidel'' text/logo, and will be placed on an aluminum sign raceway which will be painted to match the existing wall color. The sign will also be internally illuminated. Additionally the plans are proposing two non-illuminated directional signs, identified as signs 'B' on the plans. These directional signs are only 36 inches in height and 7.5 square feet in area each. These two signs will be placed in locations on the site which will help direct delivery vehicles to the appropriate shipping and receiving bays. Other lots within the CRC have been allowed similar types of directional signs. The plans are also proposing three door vinyl graphics, identified as signs 'C' at distinct entries to the building. Finally, the submitted plans are proposing 8 loading dock sign panels, which will be painted gray and be placed over each of the existing loading docks, to help direct delivery vehicles. The proposed internally illuminated wall sign for a single tenant building is consistent with the CRC Design Guidelines, and therefore is considered APPROVED. The two directional signs, three door vinyl graphics and loading dock sign panels are also consistent with the Design Guidelines in that they provide internal lot directional assistance and therefore are considered APPROVED. You may proceed with the construction and installation of your signs once a sign permit is obtained from the City of Carlsbad. Please forward a copy of your City sign permit to: Mrs. Andrea Tagle Meissner Jacquet 4995 Murphy Canyon Road, Suite 100 San Diego, CA 92123 1530 Faraday Avenue Suite I 00 • Carlsbad, CA 92008 • (760) 931-0780 • (760) 931-5744 Fax Carlsbad Research Center Architectural Review Committee If you have any questions or require additional information, please feel free to contact either Andrea Tagle with Meissner Jacquet at (858) 373-2100, or me at (760) 931-0780 ext. 110. Sincerely, Eddie Nava ARC Staff cc: G. Barberio, C. Reilly, T. Hageman, R. Tschantz, A. Tagle 1530 Faraday Avenue Suite 100 • Carlsbad, CA 92008 • (760) 931-0780 • (760) 931-5744 Fax Carlsbad Research Center Architectural Review Committee CARLSBAD RESEARCH CENTER • ARCHITECTURAL REVIEW COMMITTEE Sign Evaluation Matrix for: QUIDEL -Wall Sign (6/8/2021) Applicant Address: 2285 Rutherford Road Building Area: > 60,000 ft Sign Criteria CRC Design Guidelines Number of signs per lot Building area: > 60,000 ft'= 1 Monument Sign OR 1 wall (Single tenant building) sign Number per elevation Monument Sign: 1 per lot. Sign dimensions Not soecified Area 50.0 ft" maximum (monument or wall) Sign Height Monument sign: > 3 feet, sign must observe building setback of 30 ft. s 3 feet, at least 20 feet from curb Wall Sign: Below eave line Sign Depth Monument signs must be at least 8 inches in depth No standard for wall sians Size of lettering/logo Monument Sign: 18 inches maximum Monument Sign: Address lettering s ?inches (Helvetica) Wall Sign: 24 inches maximum if building area is< 35,000 ft2 36 inches maximum if buildino area is > 35,000 ft2 Area of Lettering & logo Percent coverage of Logo/logotype area may not exceed 1 /3 of total sign area. letterino and looo No standard for wall signs Lighting Must be internally lit Location Monument sign: Near the primary access point to the lot. Wall sign: May not be mounted on any architectural projection, parapet, equipment enclosure or on glass portions of buildina elevations 1- CRC Lot No: 16 Proposed Dimensions- Information QUIDEL (wall sign on north elevation) OK QUIDEL (single wall sign on north elevation) OK 17'-3¼"x2'-10½" 49.65 ft" OK Wall sign on north wall elevation below eave line OK NIA Wall Sign - Lettering/Logo= 34.5" OK 49.65 ft' OK NIA Wall sign is internally illuminated OK Wall sign on north wall elevation; not on glass OK The proposed sign is consistent with the Design Guidelines of the CRC. 2-Interior lot directional signs, directional door vinyl graphics and loading dock sign panels are consistent with Desian Guidelines of the CRC. Items In bold face are not In conformance with the Design Guldellnes of the CRC. 1530 Faraday Avenue Suite I 00 • Carlsbad, CA 92008 • (760) 931-0780 • (760) 931-5744 Fax -- ~t j )\ ~?1; .. , --I. -- ?/ \ 8 ·i-11 8 J .. -I I ,/j i ---~i 1). _ ____,! -+--i-l_i_f .. -.. -.... -. I SITE PLAN SCALE: 1" = 90'-0" .. -.. 2285 RUTHERFORD ROAD EXISTING 2 STORY BUILDING TYPE Ill-A CONSTRUCTION, SPRINKLERED .... ' ' ' 1 2 3 4 . ... ....,._,..,. __ _ I LOADING DOCKS L---_____ ..J ij I MCCLELLAN PALOMAR AIRPORT PROPERTY OWNER: BPP PACIRC INDUSTRIAL CA NON-R8T OWNER 2 LLC ADDRESS: 2285 RUTHERFORD ROAD CARLSBAD, CA 92008 LEGAL DESCRIPTION: PAR 16\ APN#: 2120620800 LOT SIZE: 6.55 ACRES SUBDIVISION: SUBMAP 010330 SIGN LEGEND CD CD CD ~ FACE-UT FABRICATED ALUMINUM CHANNEL LOGO & LETTERS. 2'-10 1/2" HT LOGO, 1'-7 1/2" HT LETTERS@ 17'-3 1/4' OVERALL SPAN. D/F NON-ILLUMINATED DIRECTIONAL SIGN. 36" HT X 30' W DIRECTIONAL SIGN (TYP. OF 2). NON-ILLUMINATED DOOR VINYL GRAPHICS. NON-ILLUMINATED ACM LOADING DOCK SIGN PANEL. 20· HT X 2o·w SIGN PANEL (TYP. OF 8). QUIDEL Project Location: 2285 Rutherford Rd Carlsbad, CA 92008 ProjectNo.: 210132• 1 Op Salesman: Aaron Clippinger Designer: ArnieM. Date: February 24, 2020 Scale: 1 "=90'-0" Revision: & 01 -revised key 04.26.21 ffi AR-added copy 05.25.21 6 L L L L L L L L L L ~ Integrated SIGNS L ' I ' • l1 Ill L, T • ..,G.r-c I ' 1160 Pioneer Way, Suite M El Cajon, California 92020-1944 T: 619.579.2229 I F: 619.579.7651 isasign.com I info@isasign.com ORIGINAL CONCEPT This design is the exclusive properly of Integrated Signs and cannot be reproduced In whole or part without their prior written consent. Sheet No.: 1 /6 3'-8" WIREWAY 2·-10 112· I LOGO 1'-7 ½' L= $ 31'-11" AFG 26'-4"± BOTTOM OF WIREWAY $ 0'-0' AFG 1------------------18'-6" WIREWAY------------------l i-----------------17'-3 ¼' OVERALL SPAN --------------~ 2 -1ov,·1 EO. 3'-8" WIREWAY EO. SCALE: 3/8' = 1 '-0' PROPOSED SIGN LOCATION r EQ .. --1----18'-6' WIREWAY 0 QUANTITY: 1 SET I 49.65 SF SIGN SPECIFICATIONS WIREWAY: 2' DP. FABRICATED ALUMINUM WIREWAY WI PAINTED FINISH. RETURNS: 3" DP., .040' ALUMINUM. FACE: 3/16' THK. ACRYLIC FACES. EDGES: VINYL: LOGO· 5/8"± ALUMINUM RETAINERS LETTERS -1' TRIMCAP EDGES. LOGO-FIRST SURFACE APPLIED DIGITAL FILM. ILLUM.: WHITE LED ILLUMINATION. INSTALL: SURFACE MOUNT ON BUILDING WALUGLASS AS REQUIRED. NOTE: FIELD VERIFY DIMENSIONS & INSTALLATION METHOD. FACE-LIT CHANNEL LOGO & LETTERS SCALE: 1/8" 1'-0 " □ • FACES: WHITE #7328 LD ACRYLIC FACE □ 0 RETURNS: MATTE WHITE FINISH □ • RETAINERS: MATTE WHITE FINISH □ • WHITE 1 ' TRIMCAP EDGES II • DIGITAL PRINT -UV LAM □ 0 BEIGE TO MATCH WALL COLOR (VERIFY) ■ QUIDEL Project Location: 2285 Rutherford Rd Carlsbad, CA 92008 ProjectNo.: 210132•10p Salesman: Aaron Clippinger Designer: ArnieM. Date: February 24, 2020 Scale: As noted Revision: &_ AR-revised size 03.10.21 & TA • rev. letter ht. 03.30.21 v~ ~/4 Integrated SIGNS OPE.AM I • LD •T • 51GN IT 1160 Pioneer Way, Suite M El Cajon, California 92020-1944 T: 619.579.2229 I F: 619.579.7651 isasign.com I info@isasign.com ORIGINAL CONCEPT This design is the exclusive property ol Integrated Signs and cannot be reproduced in whole or part wilhout their prior written consent. Sheet No.: -,--- 4" j__ ___L_ 2½" 28" .,-- .- 43/4" ~ aOUIDEL SHIPPING & RECEIVING ~ SIDE "B" ~30'~ .---t-------t-----, ______ 2" DP. FABRICATED I I I I I I I I I I I I I __ I QUIDEL SHIPPING & ---0 ALUMINUM DIRECTIONAL SIGN W/ PAINTED FINISH RECEIVING ---+-----3M VINYL OVERLAY ➔ SIDE "A" I I I GRAPHICS NOTE: VERIFY ARROW DIRECTION & INSTALL LOCATIONS ~---FINISH GRADE :-----2" SQ. TUBE POST 1 (TYP. OF 2) 1 INSTALL: 1 : DIRECT BURIAL (VERIFY) I I I I __ I CD QUANTITY: 2 I 5.83 SF D/F NON-ILLUMINATED DIRECTIONAL SIGN SCALE: 1" = 1 '-0" END VIEW □ • SATIN WHITE FINISH • 3M BLACK #7725-12 VINYL FILM II • DIGITAL PRINT -UV LAM QUIDEL Project Location: 2285 Rutherford Rd Carlsbad, CA 92008 ProjectNo.: 210132-11 p Salesman: Aaron Clippinger Designer: ArnieM. Date: February 24, 2020 Scale: As noted Revision; & AR-revised size 03.10.21 Lt_ OL -quantity 2 04.26.21 L'.J)i. OL· reduced size 06.11.21 v~ ~/4 Integrated SIGNS DREAM IT • BUILD IT• SIGN IT 1160 Pioneer Way, Suite M El Cajon, California 92020-1944 T: 619.579.2229 I F: 619.579.7651 isaslgn.com I info@isasign.com ORIGINAL CONCEPT This design ls the exclusive property of Integrated Signs and cannot be reproduced in whole or part without their prior written consent. Sheet No.: . ' 1-----------14 112· -------1 ENLARGED DOOR GRAPHICS I SCALE: 1112• m 1•-0• LOFDOOR TYP. OF 1 DOOR VINYL GRAPHICS SCALE: 3/4" 1 '-0" 0 QUANTITY: 3 LOGO I 1.21 SF GRAPHICS: LOGO- DIGITALLY PRINTED COLOR LOGO. APPLY FIRST SURFACE. LETTERS - 3M WHITE #7725-10 VINYL OVERLAY LETTERS. APPLY FIRST SURFACE. TYP. OF 2 EQ. ---I1-~0'AFF"" EQ. ■ QUIDEL Project Location: 2285 Rutherford Rd Carlsbad, CA 92008 ProjectNo.: 210132•10p Salesman: Aaron Clippinger Designer: ArnieM. Date: February 24, 2020 Scale: As noted Revision: & OL -add etxtra door 06.0121 ~ Integrated SIGNS 1160 Pioneer Way, Suite M El Cajon, California 92020-1944 T: 619.579.2229 I F: 619.579.7651 lsasign.com I info@isasign.com ORIGINAL CONCEPT This design Is the exclusive property of Integrated Signs and cannot be reproduced in whole or part without their prior written consent. Sheet No.: t L OF OPENING i f L OF OPENING 3'-3" 20· 11 7/15" LOADING DOCK SIGN PANEL SCALE: 3" = 1 '-0" INSTALL LOCATIONS QUANTITY: 8 SIGN PANELS (NUMERALS 1 THRU 8) SIGN PANEL: 3MM ACM WHITE PANEL W/ FIRST SURFACE APPLIED 3M MEDIUM GRAY #7725-31 VINYL FIELD W/ 3M DARK GRAY #772S-41 VINYL OVERLAY NUMERALS. ILLUM.: NON-ILLUMINATED. INSTALL: SURFACE MOUNTED TO BUILDING WALL W/ 3M VHB & SILICONE ADHESIVE. ¢L OF OPENING 1 12· 0 1it 11 TYPICAL INSTALLATION SCALE: 3/16"-1'-0" QUIDEL Project location: 2285 Rutherford Rd Carlsbad, CA 92008 Project No.: 210132-1 Op Salesman: Aaron Clippinger Designer: ArnieM. Date: February 24, 2020 Scale: As noted Revision: ,& Ol -only 6 panels 04.26.21 & OL -add 2 more panels 05.28.21 ~ Integrated SIGNS ORFAv\ I • BUI NI 1160 Pioneer Way, Suite M El Cajon, California 92020-1944 T: 619.579.2229 I F: 619.579.7651 isasign.com I info@isasign.com ORIGINAL CONCEPT This design Is the exclusive property of Integrated Signs and cannot be reproduced In whole or part without their prior written consent. Sheet No.: LAG BOLT & SHIELD (PER WALL CONST.) ---' FABRICATED ALUMINUM . . . : .... PANEL W/ TOP DOOR . • •• • · ... ACCESS & DISCONNECT SWITCH ----1'-'-------'-......:.ii---... • .•. _-.· · ... ·.:: ·:. : : .. · .. .040" ALUMINUM CHANNEL RETURNS LOGO: ALUMINUM RETAINERS LETERS: 1 • TRIMCAP EDGES WI RETAINING SCREWS 3/16"THK. ACRYLIC FACE RIGID CONDUIT THRU WALL (SEAL ALL WALL PENETRATIONS) ---- . . .. •• •• -_· ....... ....r, 120VDISCONNECT ~ TOGGLE SWITCH ~ • TO 120V 20 AMP _J DEDICATED CIRCUIT WI AUTOMATIC CONTROL (BY OTHERS) -----3MM ACM BACKS - PAINT INTERIOR WHITE ·.·._:·.-.·.::,:. :: ----11,---LOW VOLTAGE WHITE LED MODULES .. •,. •, ... . _ .. ,• . : .· : : • . • : ..•. .... .. . . . . . . . ·: : •. -· .· : .... . • . .-...... .. · .. . · .•. .... . . •. -·· .. · .. •• ·.: • • • ♦ -.... -,--,11---1/4" DRAIN HOLES W/ LIGHT BAFFLES (TYP. PER LTR.) .__ _____ LOW VOLTAGE TRANSFORMER ~--FABRICATED ALUMINUM WIREWAY BUILDING WALL (VERIFY WALL CONSTRUCTION) .;:;.S=EC=T;:_:_10..;:;...;;..;N;...;;D;;..;;E;;;..;T..;..;A=IL;;...._ ______________ ~ SCALE: 1 1/2" -1'-0" ~ GROUNDING & BONDING: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE ANDiOR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. DISCONNECT SWITCH THE LOCATION OF THE DISCONNECT SWITCH AFTER INSTALLATION SHALL COMPLY WITH ARTICLE 600.6 (A) (1) OF THE NATIONAL ELECTRICAL CODE QUIDEL Project l ocation: 2285 Rutherford Rd Carlsbad, CA 92008 Project No.: 210132-1 Op Salesman: Aaron Clippinger Designer: ArnieM. Date: February 24, 2020 Scale: 11/2"=1'-0" Revision: ~ Integrated SIGNS , A,~ , r . BIJIL ~ 1 r • s1CN , , 1160 Pioneer Way, Suite M El Cajon, California 92020-1944 T: 619.579.2229 I F: 619.579.7651 isasign.com I fnfo@isasign.com ORIGINAL CONCEPT This design is the exclusive property of Integrated Signs and cannot be reproduced in whole or part without their prior written consent. Sheet No.: