Loading...
HomeMy WebLinkAboutPS 2021-0050; STEEZ FINE BARBERING; Sign Permits/Programs (PS)Ccityof Carlsbad REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov "f)~v '2,Qz_. I -o t 3 I PLANNING APPLICATION# f .5 Z--o 2--1 -oo S-e> REC'D BY SlYCM-:L C I"' {( DATE (, I 2..bl 2., I SIGNFEE $~7.ie- SIGN PROGRAM FEE ________ _ RECEIPT NO. ___________ _ NOTE: AN APPOINTMENT IS REQUIRED FOR SUBMITTAL. PLEASE CONTACT THE APPOINTMENT SPECIALIST AT (760) 602- 2723 TO SCHEDULE AN APPOINTMENT. *SAME DAY APPOINTMENTS ARE NOT AVAILABLE• All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. No Freestanding signs 4. Distance to the property line(s) for all proposed freestanding sign(s). ~are proposed 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. Average processing time: 2 weeks Steez Fine Barbering, LLC new tenant storefront signage Name of Project: ___________________________ _ Address of Project: _s_8_14_V_an_A_lle_n_w_a_..:y_,_c_a_rls_b_a_d_C_A_9_2_0_0_8 ____________ _ Assessor Parcel Number: __ 2_1_2-_1_20_-_5_6-_0_0 _________________ _ Related Planning Case Number(S): ____________________ _ TYPE OF DEVELOPMENT: (a) Residential (d) Hotel/Motel {t:l') Commerdab (e) Service Station (c) Office/Industrial (f) Prof. Care (g) Theater (h) Gov't/Church/School (i) Public Park SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA 0) Produce Stand (k) Nursery (I) P-U/OS Zone Yes [R] No □ Specific Plan Number _16_-_80 __ _ VILLAGE REVIEW AREA (If yes. please complete information on page 3) Yes D SOUTH CARLSBAD COASTAL REVIEW AREA Yes □ SIGN ORDINANCE: Yes 0 No O COASTAL ZONE: Yes O No~ P-11 Page 1 of 4 No~ No[[] Rev. 02/28/18 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole 0 Monument 0 Wall 0 Suspended/Projecting 0 Directional 0 Canopy 0 Freestanding (Project Identity) 0 PERMITS ISSUED FOR EXISTING SIGNS: Yes □ No □ Date ______ _ PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Pole** 0 Monument** 0 Wall 1 23 17.5 2'2" Suspended/Projecting 0 Directional 0 Canopy 0 Freestanding** 0 (Project Identity) Digital Display 0 PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER SIGN SIGN SIGN ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT Construction** 0 For Sale** 0 Banner 0 Interim 0 **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of- way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2 of 4 Rev. 02128/18 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I I ' P/L Sight Distance Requirement ; l Show building/s i I I ! I i I , _____ , Show setbacks from all curbs --- ' ! I I ! I Show all property lines I P/L : ! I : : . I curb line . ! ! -----------~--- • • Sight Visibility I Street Name(s) (i) I I North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: -----~---20 Linear Feet Tot a I Building Street Frontage: ________ _ Total Signage Allowance: -----=----- Existing Signage (sq. ft.):-----~--- Remaining Sign Allowance at Present: ________ _ Proposed Signage (sq. ft.): ________ _ 23 Square feet 0 23 Square feet 17 .5 Square feet 2.5 Square feet Remaining Sign Allowance After Proposed Sign: ________ _ sq. ft. linear ft. sq. ft. sq. ft. sq. ft. sq. ft. sq. ft. VILLAGE REVIEW AREA Total Signable Area: ________ sq. ft. Total Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: inches P-11 Page 3 of 4 Rev. 02/28/18 PROPERTY OWNER APPLICANT NAME (PRINT OR TYPE) NAME (PRINT OR TYPE) No man is an island, LLC Torrey Pines Building and Signage Inc. c/o Capstone Advisors Inc. as its aaent dba Signarama San Marcos MAILING ADDRESS MAILING ADDRESS 1545 Faraday Ave 215 S. Pacific Street, Suite 103 CITY STATE ZIP TELEPHONE CITY -STATE ZIP TELEPHONE Carlsbad, CA 92008 San Marcos, CA 92078 I CERTIFY THAT I AM THE LEGAL OWNER I CERTIFY THAT I AM THE REPRESENTATIVE AND THAT ALL THE ABOVE INFORMATION OF THE LEGAL OWNER AND THAT ALL THE IS TRUE AND CORRECT TO THE BEST OF ABOVE IN FORMATION IS TRUE AND CORRECT MY KNOWLEDGE. TO THE BEST OF MY KNOWLEDGE. r-~tv:~ ~~~--.-tw~,~... - 6/22/2021 Brooks Roffey ~f§f:=-06/22/2021 ~,:,"Df~:=---... SIGNATURE DATE SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: In right-of-way In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: ~ ~ Date: /, • 2.1>-2..I P-11 Page 4 of 4 Rev. 02/28118 Carlsbad Research Center June 23, 2021 Ms. Gabi Davis NO MAN IS AN ISLAND, LLC 1545 Faraday A venue Carlsbad, CA 92008 Re: Lot 73-1 -STEEZ FINE BARBERJNG Wall Sign Review Dear Ms. Davis, Architectural Review Committee The Architectural Review Committee (ARC) of the Carlsbad Research Center (CRC) has reviewed your application for one wal l sign submitted on behalf of your tenant, Steez Fine Barbering, for your building located at 5814 Van Allen Way, Suite 200. The proposed plans for a single wall sign are consistent with the CRC Design Guidelines and the Island at Carlsbad Sign Program (October I 8, 2016), therefore the submitted plans are considered APPROVED. You may proceed with the construction and installation of your sign once a sign permit is obtained from the City of Carlsbad. Please forward a copy of your City sign permit to: Mrs. Andrea Tagle Meissner Jacquet 4995 Murphy Canyon Road, Suite 100 San Diego, CA 92123 If you have any questions or require additional information, please feel free to contact either Andrea Tagle with Meissner Jacquet at (858) 373-2100 or me at (760) 93 1-0780 ext. 110. Sincerely, Eddie Nava ARC Staff cc: G. Barberio, C. Reilly, T. Hageman, R. Tschantz, A. Tagle 1530 Faraday Avenue Suite I 00 • Carlsbad, CA 92008 • (760) 931-0780 • (760) 931-5744 Fax Carlsbad Research Center Architectural Review Committee CARLSBAD RESEARCH CENTER -ARCHITECTURAL REVIEW COMMITTEE Sign Evaluation Matrix for: Steez Fine Barbering Wall Sign (6/23/2021) Applicant Address: 5814 Van Allen Way, Suite 200 Sign Criteria CRC Design Guidelines/ Island at Carlsbad Sign Program Number of signs per lot 1 Sian for this suite Sign dimensions Not specified Area 23.0 ffZ Maximum (Storefront X 1.15 ft2; 20 X 1.15 = 23.0 ft2) Size of lettering 26 inches maximum Letterina Type Illuminated Aluminum Channel Letters Liqhtinq Must be internally lit Location Per approved location on Page 9 of 'The Island at Carlsbad Sian Proaram' CRC Lot No: 73-1 Proposed Dimensions- Information OK 6'-3" X 2'-2" OK 17.5 ft' OK 26inches OK OK OK OK 1-The proposed sign is consistent with the Design Guidelines of the CRC as well as the Island at Carlsbad Sian Program. Items in bold face are not in conformance with the Design Guidelines of the CRC. 1530 Faraday Avenue Suite 100 • Carlsbad, CA 92008 • (760) 931-0780 • (760) 931-5744 Fax 6' 3" 4'3" Primary Sign: "Steez" logo: front and back(halo) lit. See Section 1 for detail. -Plex face -Surface 1 applied vinyl -Satin Blue front, White back -White Trim Cap, Painted White sides Available Size Calculation: 1) Per "Island" Approved Comprehensive Sign Program dated 10/14/2016 (sign permit 16-80 approved on 9/29/2016), Page 5 paragraph D: 1.15 square foot to each 1.0 linear foot of storefront is available for use. 1.1) Available size: 20 linear feet (storefront) X 1.1 5 = 23 square feet of available space. ---V4 06/XX/21 1.2) Adjacent Surface: 20' X 4.5' = 90 Square Feet en er sIgnage guI elines paragraph 6.9.3: Commercial/ t be are feet. Actual Size Calculation: 1) Primary Sign: 6.3' X 2.2' = 14.0 square feet 6.3'/20' = 32% of adjacent surface length 2.2'/4.5' = 49% of adjacent surface height 2) Secondary Sign: 4.25' X .8' = 3.5 square feet 3.5sf/23sf = 15% of total allowable sign area 3) Total size= 17.5 square feet V4 06/XX/21 1.5' 1 Stand-off PRE-FABRICATED h 3 5" HI · UMINUM CHANNEL RETURNS RETURNS PAINTED FINISH--~ • .--::· GROUND WIRE--~ 1/8" THK. PLEX FACES WITH FIRST-SURFACE APPLIED TRANSLUCENT VlNYl OVERLAYS----~• LOW VOlJAGE LED MODULES ----1,0 3/16" THI<. CLEAR PLEX BACKS SCREWS w/ SILICONE SEALANT Anchored per wall type ALUMINUM ANGLE SUPPORT ------' 1/4' DRAIN HOLE SECTION 1 :::-·-4-1--BUILDING WAU ~-1-1--CONDUIT (SEAL ALL WALL PENETRAnONS) LOW VOLTAGE TRANSFORMER JUNCTION BOX DISCONNECT SWITCH ----- SIGN TO BE UL APPROVED AND BEAR UL LABEL PLEX FACED CHANNEL LITTERS WITH THROUGH FACE & HALO LED ILLUMINATION Reconnect to existing circuit controlled by timeclock and photocell by client electrician under Tl permit Secondary Sign: "Fine Barbering" 3/8" thick contour cut painted satin blue acrylic lettering. Flush mounted to the exterior wall. 1" long #10 threaded studs mounted to the back of the letters. Drilled and silicone applied to each opening.