Loading...
HomeMy WebLinkAboutAccent Electronics d.b.a. Standard Electronics; 2024-10-15; PWM25-3589FACPWM25-3589FAC Cole Library Fire Alarm Replacement Page 1 City Attorney Approved 6/5/24 CITY OF CARLSBAD MINOR PUBLIC WORKS CONTRACT COLE LIBRARY FIRE ALARM REPLACEMENT This contract is made on the ______________ day of _________________________, 2024 (“Contract”), by the City of Carlsbad, California, a municipal corporation ("City") and Accent Electronics, a California corporation, d.b.a. Standard Electronics, whose principal place of business is 613 West Main Street, El Cajon, California 92020 ("Contractor"). City and Contractor agree as follows: DESCRIPTION OF WORK. Contractor shall perform all work specified in the Contract documents for the project described by these Contract Documents (hereinafter called "Project"). PROVISIONS OF LABOR AND MATERIALS. Contractor shall provide all labor, materials, tools, equipment, and personnel to perform the work specified by the Contract Documents unless excepted elsewhere in this Contract. CONTRACT DOCUMENTS. The Contract Documents consist of this Contract, exhibits to this Contract, Contractor's Proposal, the Plans and Specifications, the General Provisions, as contained in the Standard Specifications for Public Works Construction “Greenbook,” latest edition and including all errata; Part 1 General Provisions, addendum(s) to said Plans and Specifications, and all proper amendments and changes made thereto in accordance with this Contract or the Plans and Specifications, all of which are incorporated herein by this reference. When in conflict, this Contract will supersede terms and conditions in the Contractor’s proposal. LABOR. Contractor will employ only skilled workers and abide by all State laws and City of Carlsbad Ordinances governing labor. GUARANTEE. Contractor guarantees all labor and materials furnished and agrees to complete the Project in accordance with directions and subject to inspection approval and acceptance by Charles Balteria (City Project Manager). PAYMENT. The City shall withhold retention as required by Public Contract Code Section 9203. PREVAILING WAGE RATES. Any construction, alteration, demolition, repair, and maintenance work, including work performed during design and preconstruction such as inspection and land surveying work, cumulatively exceeding $1,000 and performed under this Contract constitute “public works” under California Labor Code Section 1720 et seq., and are subject to state prevailing wage laws. The general prevailing rate of wages, for each craft or type of worker needed to execute the contract, shall be those as determined by the Director of Industrial Relations pursuant to the Sections 1770, 1773 and 1773.1 of the California Labor Code. Consistent with the requirement of Section 1773.2 of the California Labor code, a current copy of applicable wage rates may be obtained via the internet at: www.dir.ca.gov/dlsr/. Contractor shall not pay less than the said specified prevailing rates of wages to all such workers employed by him or her in the execution of the Contract. Contractor and any subcontractors shall comply with Section 1776 of the California Labor Code, which requires keeping accurate payroll records, verifying and Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 October15th Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM25-3589FAC certifying payroll records, and making them available for inspection. Contractor shall require any subcontractors to comply with Labor Code Section 1776. DIR REGISTRATION. California Labor Code Section 1725.5 requires the Contractor and any subcontractor or subconsultant performing any public work under this Contract to be currently registered with the California Department of Industrial Relations ('DIR'), as specified in Labor Code Section 1725.5. Labor Code Section 1771.1 provides that a contractor or subcontractor/subconsultant shall not be qualified to engage in the performance of any contract for public work, unless currently registered and qualified to perform public work pursuant to Labor Code section 1725.5. Prior to the performance of public work by any subcontractor or subconsultant under this Contract, Contractor must furnish the City with the subcontractor or subconsultant's current DIR registration number. CALIFORNIA AIR RESOURCES BOARD (CARB) ADVANCED CLEAN FLEETS REGULATION. Contractor's vehicles with a gross vehicle weight rating greater than 8,500 lbs. and light-duty package delivery vehicles operated in California may be subject to the California Air Resources Board (CARB) Advanced Clean Fleets regulations. Such vehicles may therefore be subject to requirements to reduce emissions of air pollutants. For more information, please visit the CARB Advanced Clean Fleets webpage at https ://ww2.a rb. ca.gov /ou r-work/progra ms/advanced-clean-fleets. CALIFORNIA AIR RESOURCES BOARD (CARB) IN-USE OFF-ROAD DIESEL FUELED FLEETS REGULATION. Contractors are required to comply with the requirements of the In-Use Off-Road Diesel-Fueled Fleet regulations, including, without limitation, compliance with Title 13 of the California Code of Regulations section 2449 et seq. throughout the term of the Project. More information about the requirements and Contractor's required certification is provided in Exhibit D. CONSTRUCTION MANAGEMENT SOFTWARE. Procore Project Management and Collaboration System. This project may utilize the Owner's Procore {www.procore.com ) online project management and document control platform. The intent of utilizing Procore is to reduce cost and schedule risk, improve quality and safety, and maintain a healthy team dynamic by improving information flow, reducing non- productive activities, reducing rework and decreasing turnaround times. The Contractor is required to create a free web-based Procore user account(s) and utilize web-based training/ tutorials (as needed) to become familiar with the system. Unless the Engineer approves otherwise, the Contractor shall process all project documents through Procore because this platform will be used to submit, track, distribute and collaborate on project. If unfamiliar or not otherwise trained with Procore, Contractor and applicable team members shall complete a free training certification course located at http://learn.procore.com/procore-certification-subcontractor. The Contractor is responsible for attaining their own Procore support, as needed, either through the online training or reaching out to the Procore support team. It will be the responsibility of the Contractor to regularly check Procore and review updated documents as they are added. There will be no cost to the Contractor for use of Procore. It is recommended that the Contractor provide mobile access for Windows, iOS located at https :// apps.a pple .com/us/a pp/procore-construction-ma nagement/id37 4930542 or Android devices located at https://play.google.com/store/apps/details?id=com.procore.activities with the Procore App installed to at least one on-site individual to provide real-time access to current posted drawings, specifications, RFls, submittals, schedules, change orders, project documents, as well as any deficient observations or punch list items. Providing mobile access will improve communication, efficiency, and productivity for all parties. The use of Procore for project management does not relieve the contractor of any other requirements as may be specified in the contract documents. Cole Library Fire Alarm Replacement Page 2 City Attorney Approved 6/5/24 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM25-3589FAC FALSE CLAIMS. Contractor hereby agrees that any contract claim submitted to the City must be asserted as part of the contract process as set forth in this Contract and not in anticipation of litigation or in conjunction with litigation. Contractor acknowledges that California Government Code sections 12650 et seq., the False Claims Act, provides for civil penalties where a person knowingly submits a false claim to a public entity. These provisions include false claims made with deliberate ignorance of the false information or in reckless disregard of the truth or falsity of the information. The provisions of Carlsbad Municipal Code sections 3.32.025, 3.32.026, 3.32.027 and 3.32.028 pertaining to false claims are incorporated herein by reference. Contractor hereby acknowledges that the filing of a false claim may subject the Contractor to an administrative debarment proceeding wherein the contractor may be prevented from further bidding on public contracts for a period of up to five (5) years and that debarment by another jurisdiction is grounds for the City of Carlsbad to disqualify the Contractor or subcontractor from participating in contract bidding. Signature: Print Name: REQUIRED INSURANCE. The successful contractor shall provide to the City of Carlsbad, a Certification of Commercial General Liability and Property Damage Insurance and a Certificate of Workers' Compensation Insurance indicating coverage in a form approved by the California Insurance Commission. The certificates shall indicate coverage during the period of the contract and must be furnished to the City prior to the start of work. The minimum limits of liability insurance are to be placed with California admitted insurers that have a current Best's Key Rating of not less than "A-:VII"; OR with a surplus line insurer on the State of California's List of Approved Surplus Line Insurers (LASLI) with a rating in the latest Best's Key Rating Guide of at least "A:X"; OR an alien non-admitted insurer listed by the National Association of Insurance Commissioners (NAIC) latest quarterly listings report. Commercial General Liability Insurance written on an "occurrence" basis, including personal & advertising injury, with limits no less than $2,000,000 per occurrence. If a general aggregate limit applies, either the general aggregate limit shall apply separately to this project/location or the general aggregate limit shall be twice the required occurrence limit. Property damage insurance in an amount of not less than ........ $2,000,000 Automobile Liability Insurance in the amount of $2,000,000 combined single limit per accident for bodily injury and property damage. In addition, the auto policy must cover any vehicle used in the performance of the contract, used onsite or offsite, whether owned, non-owned or hired, and whether scheduled or non-scheduled. The automobile insurance certificate must state the coverage is for "any auto" and cannot be limited in any manner. The above policies shall have non-cancellation clauses providing that 30 days written notice shall be given to the City prior to such cancellation. Cole Library Fire Alarm Replacement Page 3 City Attorney Approved 6/5/24 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM25-3589FAC The policies shall name the City of Carlsbad as an additional insured. The full limits available to the named insured shall also be available and applicable to the City as an additional insured. WORKERS' COMPENSATION AND EMPLOYER'S LIABILITY. Workers' Compensation limits as required by the California Labor Code. Workers' Compensation will not be required if Contractor has no employees and provides, to City's satisfaction, a declaration stating this. BUSINESS LICENSE. The Contractor and all subcontractors are required to have and maintain a valid City of Carlsbad Business License for the duration of the contract. INDEMNITY. Contractor agrees to defend (with counsel approved by the City), indemnify, and hold harmless the City and its officers, elected and appointed officials, employees and volunteers from and against all claims, loss, damage, injury and liability of every kind, nature and description, directly or indirectly arising from or in connection with the performance of the Contract or work; or from any failure or alleged failure of Contractor to comply with any applicable law, rules or regulations including those related to safety and health; and from any and all claims, loss, damages, injury and liability, howsoever the same may be caused, resulting directly or indirectly from the nature of the work covered by the Contract, except for loss or damage caused by the sole or active negligence or willful misconduct of the City. The expenses of defense include all costs and expenses including attorneys' fees for litigation, arbitration, or other dispute resolution method. THIRD PARTY RIGHTS. Nothing in this Agreement should be construed to give any rights or benefits to any party other than the City and Contractor. JURISDICTION AND VENUE. This Agreement shall be interpreted in accordance with the laws of the State of California. The Contractor agrees and hereby stipulates that the proper venue and jurisdiction for resolution of any disputes between the parties arising out of this Contract is San Diego County, California. Start Work: Contractor agrees to start within thirty (30) working days after receipt of Notice to Proceed. Completion: Contractor agrees to complete work within ninety (90) working days after receipt of Notice to Proceed. Cole Library Fire Alarm Replacement Page4 City Attorney Approved 6/5/24 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 CONTRACTOR'S INFORMATION. Accent Electronics d.b.a. Standard Electronics (name of Contractor) 590876 (Contractor's license number) C-10 3/31/26 (license class. and exp. date) 1000004303 6/30/26 (DIR registration number/exp. date) PWM25-3589FAC 613 W. Main Street (street address) El Cajon, CA 92020 (city/state/zip) 619-596-9950 (telephone no.) nathane@standardelectronics.us (e-mail address) AUTHORITY. The individuals executing this Contract and the instruments referenced in it on behalf of Contractor each represent and warrant that they have the legal power, right and actual authority to bind Contractor to the terms and conditions of this Contract. [signatures on following page] Cole Library Fire Alarm Replacement Page 5 City Attorney Approved 6/5/24 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 Docusign Envelope ID: 2O01F816-029A-4DDA-8131 -DC95268BBCC9 CONTRACTOR ACCENT ELECTRONICS, a California corporation, d.b.a. Standard Electronics By: (sign here) Brent Dusenberry, President (print name, title) By: (sign here) Michael Dawid, CFO (print name, title) PWM25-3589FAC CITY OF CARLSBAD, a municipal corporation of the State of California By: Paz Gomez, Deputy City Manager, Public Works, as authorized by the City Manager ATTEST: SHERRY FREISINGER, City Clerk By: Deputy City Clerk If required by City, proper notarial acknowledgment of execution by Contractor must be attached. 1i....2 corporation, Contract must be signed by one corporate officer from each of the following two groups: Group A Chairman, President, or Vice-President Group B Secretary, Assistant Secretary, CFO or Assistant Treasurer Otherwise, the corporation must attach a resolution certified by the secretary or assistant secretary under corporate seal empowering the officer(s) signing to bind the corporation. APPROVED AS TO FORM: CINDIE K. McMAHON, City Attorney BY: ~lM.-th.%Vt.¥'0v Assistant City Attorney Cole Library Fire Alarm Replacement Page 6 City Attorney Approved 6/5/24 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM25-3589FAC EXHIBIT A LISTING OF SUBCONTRACTORS BY GENERAL CONTRACTOR Set forth below is the full name and location of the place of business of each subcontractor whom the Contractor proposes to subcontract portions of the Project in excess of one-half of one percent of the total bid, and the portion of the Project which will be done by each subcontractor for each subcontract. NOTE: The Contractor understands that if it fails to specify a subcontractor for any portion of the Project to be performed under the contract in excess of one-half of one percent oft he bid, the contractor shall be deemed to have agreed to perform such portion, and that the Contractor shall not be permitted to sublet or subcontract that portion of the work, except in cases of public emergency or necessity, and then only after a finding, reduced in writing as a public record of the Awarding Authority, setting forth the facts constituting the emergency or necessity in accordance with the provisions of the Subletting and Subcontracting Fair Practices Act (Section 4100 et seq. of the California Public Contract Code). If no subcontractors are to be employed on the project, enter the word "NONE." SUBCONTRACTORS Type of Work Business Name and Address DIR Registration No. License No., %of tobe & Expiration Date Classification Total Subcontracted & Expiration Contract Date NON't Total% Subcontracted: ______ _ The Contractor must perform no less than 50% of the work with its own forces. Cole Library Fire Alarm Replacement Page 7 City Attorney Approved 6/5/24 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM25-3589FAC EXHIBIT B Cole Library Fire Alarm Replacement Contractor to provide all tools, materials and labor to replace the existing Simplex 4010 fire alarm system with a Silent Knight 6808 fire alarm system at the Cole Library located at 1250 Carlsbad Village Drive, Carlsbad California 92008. All work and materials to be consistent with the Contractor's proposal dated September 17, 2024, which is attached to this agreement as Exhibit E, to complete a one-for-one replacement of the existing fire alarm system as show in Exhibit F. Project Notes General: • Contractor to pay for and obtain all permits, approvals, fees, and charges required for this project. • Contractor to maintain the worksite in a clean and workmanlike manner. • Existing wiring, conduit and raceways are to be re-used. • Contractor's warranty period shall commence on the date of system acceptance by the authorities having jurisdiction (AHJ). • New fire alarm system to monitor MX-2002 Agent Release Control Panel in room for system trouble and alarm signals. • New system to be monitored by Rancho Santa Fe Security. Closeout Documents: • Before acceptance of work and final completion, the record set of prints shall be used to prepare "As-Built" drawings in AutoCAD 2014 or newer version, reflecting any and all changes and deviations made to the fire alarm system. The drawings shall indicate, at the minimum, the following: o As-built physical routing of wires to devices, including junction box locations. o As-built riser diagram showing the zoning of signaling line circuits. o As-built panel wiring diagrams of the fire alarm controlpanel(s). o As-built address list showing, for each device, the address, device type, location, and field custom message. o Floor plan showing each alarm-initiating device, notification appliance, control and monitoring point with their respective address identification number (i.e., an address of (5-24) for the 24th device on circuit 5). • Upon the City's review and acceptance of the record "As-Bult" drawings, one copy ofthe drawings are to be provided in AutoCAD 2014 or newer version, one copy of the drawings is to be provided in PDF format, and two (2) additional sets of printed drawings shall be delivered. • Contractor to provide a complete set of "as-built" data sheets for all equipment connected to the system. • Contractor to provide a copy (USB thumb drive) of the software used to program the system. • Contractor to provide NFPA 72 completion certificate, signed by the AHJ. Cole Library Fire Alarm Replacement Page 8 City Attorney Approved 6/5/24 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM25-3589FAC JOB QUOTATION ITEM NO. UNIT QTY DESCRIPTION PRICE 1 LS 1 Cole Library Fire Alarm Replacement $43,074 TOTAL* $43,074 *Includes taxes, bond, fees, expenses and all other costs. Cole Library Fire Alarm Replacement Page9 City Attorney Approved 6/5/24 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 Docusign Envelope ID: 2D01F816-029A-4DDA-8131-DC95268BBCC9 EXHIBITC LABOR AND MATERIALS BOND Bond No.: 800181213 Premium: $431.00 PWM25-3589FAC WHEREAS, the City Council of the City of Carlsbad, State of California, has awarded to Accent Electronics d.b.a. Standard Electronics (hereinafter designated as the "Principal"), a Contract for: COLE LIBRARY FIRE ALARM REPLACEMENT CONTRACT NO. in the City of Carlsbad, in strict conformity with the drawings and specifications, and other Contract Documents now on file in the Office of the City Clerk of the City of Carlsbad and all of which are incorporated herein by this reference. WHEREAS, Principal has executed or is about to execute said Contract and the terms thereof require the furnishing of a bond, providing that if Principal or any of its subcontractors shall fail to pay for any materials, provisions, provender or other supplies or teams used in, upon or about the performance of the work agreed to be done, or for any work or labor done thereon of any kind, the Surety on this bond will pay the same to the extent hereinafter set forth. NOW, THEREFORE, WE, Accent Electroncis d.b.a. Standard Electroncis, as Principal, (hereinafter designated as the "Contractor"), and Atlantic Specialty Insurance Company as Surety, are held firmly bound unto the City of Carlsbad in the sum of forty-three thousand seventy-four dollars ($43,074), said sum being an amount equal to: One hundred percent (100%) of the total amount payable under the terms of the Contract by the City of Carlsbad, and for which payment well and truly to be made we bind ourselves, our heirs, executors and administrators, successors, or assigns, jointly and severally, firmly by these presents. THE CONDITION OF THIS OBLIGATION IS SUCH that if the Contractor or his/her subcontractors fail to pay for any materials, provisions, provender, supplies, or teams used in, upon, for, or about the performance of the work contracted to be done, or for any other work or labor thereon of any kind, consistent with California Civil Code section 9100, or for amounts due under the Unemployment Insurance Code with respect to the work or labor performed under this Contract, or for any amounts required to be deducted, withheld, and paid over to the Employment Development Department from the wages of employees of the contractor and subcontractors pursuant to section 13020 of the Unemployment Insurance Code with respect to the work and labor, that the Surety will pay for the same, and, also, in case suit is brought upon the bond, reasonable attorney's fees, to be fixed by the court consistent with California Civil Code section 9554. This bond shall inure to the benefit of any of the persons named in California Civil Code section 9100, so as to give a right of action to those persons or their assigns in any suit brought upon the bond. Surety stipulates and agrees that no change, extension of time, alteration or addition to the terms of the Contract, or to the work to be performed hereunder or the specifications accompanying the same shall affect its obligations on this bond, and it does hereby waive notice of any change, extension of time, alterations or addition to the terms of the contract or to the work or to the specifications. In the event that Contractor is an individual, it is agreed that the death of any such Contractor shall not exonerate the Surety from its obligations under this bond. Cole Library Fire Alarm Replacement Page 10 City Attorney Approved 6/5/2.4 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 Docusign Envelope ID: 2D01F816-029A-4ODA-8131-DC95268BBCC9 PWM25-3589FAC This labor and materials bond may be approved as to form by the City Attorney for the City in counterpart, and the counterparts shall all constitute a single, original instrument. SIGNED AND SEALED, this __ 7_t_h __ day of _____ O_c_t_o_b_e_r ____ _, 2024. Accent Electronics dba Standard Electronics (SEAL) (Principal) (Signature) Atlantic Specialty Insurance Company (SEAL) (Surety) {Signature) Michelle Anne McMahon, Attorney-in-Fact (SEAL AND NOTARIAL ACKNOWLEDGEMENT OF SURETY-ATTACH ATTORNEY-IN-FACT CERTIFICATE) APPROVED AS TO FORM: CINDIE K. McMAHON, City Attorney By: Assistant City Attorney Cole library Fire Alarm Replacement Page 11 City Attorney Approved 6/5/24 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 CALIFORNIA ,ACK~OWLEDGMENT CIVIL CODE § 1189 mu U08?0ffl 1111 ,u nu:, i 9 0 80:A@:fl:OH!jl UOHI Ill@ g O IUO 0:INJ B ti D LI tolU:110@ c;u O I iziMJ»ioooooiftd ~ a a , A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. State of Ca~ia fl}(>i County of ~V\ lll ~\') On m (it1VY--t 'h i Date personally appeared ___ ......... V.:....{M~~.__ _ __.,.__._1e=c..><.."--,.._,;...,......;__,~------------- who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) ls/are subscribed to the within Instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. ' TAWNYA D. SILVAS '<otar, Public • California z "'t:.f! · -, . , • s~~ Die!<> County z ~,..,.._...,""",..E' Commission!/ 2373&6! My Comm. Expires Oct 2. 2025 Place Notary Seal and/or Stamp Above I certify under PENAL TY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. OPTIONAL Completing this informatioh can deter alteration of the document or fraudulent r; ttachment of this form to an unintended document. Description of Attached Docu Title or Type of Document: ___ .......,. _______________________ _ Document Date: _________ ,......,. ___________ Number of Pages: ___ _ Signer(s) Other Than Named Above:----".....-------------------- Capacity(ies) Claimed by Signer(s) Signer's Name: ____________ _ igner's Name: ____________ _ o Corporate Officer -Title(s): ______ _ □ orporate Officer -Title(s): ______ _ o Pa.,rtner -o Limited □ General □ P ner -□ Limited □ General o Individual o Attorney in Fact □ lndi • ual □ Attorney In Fact o Trustee o Guardian or Conservator □ Truste o Guardian or Conservator o Other: □ Other: Signer is Representing: _________ _ Signer ls Repr ©2019 National Notary Association Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 NOTARY ACKNOWLEDGMENT OF SURETY: State of Connecticut County of Hartford ss. On this the 7th day of October , 20 -1!_, before me, Rhonda Tischofer, the undersigned officer, personally appeared Michelle Anne McMahon , known to me (or satisfactorily proven) to be the person whose name is subscribed as Attorney-In-Fact for Atlantic Specialty Insurance Company , and acknowledged that s/he executed the same as the act of his/her principal for the purposes therein contained. In witness whereof I hereunto set my hand. ~ ~ ~otaryPublic Date Commission Expires: January 31, 2029 Rhonda Tischofer Printed Name ofNotary RHONDA TISCHOFER NOTARY PUBLIC -#190920 STATE OF CONNECTfCUT My Commiesior. Expires Jan. 31, 2029 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 Power of Attorney KNOW ALL MEN BY THESE PRESENTS, that ATLANTIC SPECIALTY INSURANCE COMPANY, a New York corporation with its principal office in Plymouth, Minnesota, does hereby constitute and appoint: Connor Wolpert, Doritz.a Mojica, Gentry Stewart, Jennifer Godere, Jonathan Gleason, Joshua Sanford, Kathryn Pryor, Michelle Anne McMahon, Nicholas Miller, Richard Hackner, Robyn Salley, Sarah Murtha, each individually if there be more than one named, its true and lawful Attorney-in-Fact, to make, execute, seal and deliver, for and on its behalf as surety, any and all bonds, recognizances, contracts of indemnity, and all other writings obligatory in the nature thereof; provided that no bond or undertaking executed under this authority shall exceed in amount the sum of: unlimited and the execution of such bonds, recognizances, contracts of indemnity, and all other writings obligatory in the nature thereof in pursuance of these presents, shall be as binding upon said Company as if they had been fully signed by an authoriz:ed officer of the Company and sealed with the Company seal. This Power of Attorney is made and executed by authority of the following resolutions adopted by the Board of Directors of ATLANTIC SPECIAL TY INSURANCE COMPANY on the twenty-fifth day of September, 2012: Resolved: That the President, any Senior Vice President or Vice-President (each an "Authorized Officer") may execute for and in behalf of the Company any and all bonds, recognizances, contracts of indemnity, and all other writings obligatory in the nature thereof, and affix the seal of the Company thereto; and that the Authorized Officer may appoint and authorize an Attorney-in-Fact to execute on behalf of the Company any and all such instruments and to affix the Company seal thereto; and that the Authorized Officer may at any time remove any such Attorney-in-Fact and revoke all power and authority given to any such Attorney-in- Fact. Resolved: That the Attorney-in-Fact may be given full power and authority to execute for and in the name and on behalf of the Company any and all bonds, recognizances, contracts of indemnity, and all other writings obligatory in the nature thereof, and any such instrument executed by any such Attorney-in-Fact shall be as binding upon the Company as if signed and sealed by an Authorized Officer and, further, the Attorney-in-Fact is hereby authorized to verify any affidavit required to be attached to bonds, recognizances, contracts of indemnity, and all other writings obligatory in the nature thereof. This power of attorney is signed amt sealed by facsimile under the authority of the following Resolution adopted by the Board of Directors of ATLANTIC SPECIAL TY INSURANCE COMPANY on the twenty-fifth day of September, 2012: Resolved: That the signature of an Authorized Officer, the signature of the Secretary or the Assistant Secretary, and the Company seal may be affixed by facsimile to any power of attorney or to any certificate relating thereto appointing an Attorney-in-Fact for purposes only of executing and sealing any bond, undertaking, recognizance or other written obligation in the nature thereof, and any such signature and seal where so used, being hereby adopted by the Company as the original signature of such officer and the original seal of the Company, to be valid and binding upon the Company with the same force and effect as though manually affixed. IN WITNESS WHEREOF, ATLANTIC SPECIALTY INSURANCE COMPANY has caused these presents to be signed by an Authorized Officer and the seal of the Company to be affixed this first day of January, 2023. STATE OF MINNESOTA HENNEPIN COUNfY By Sarah A. Kolar, Vice President and General Counsel On this first day of January, 2023, before me personally caine Sarah A. Kolar, Vice President and General Counsel of ATLANTIC SPECIALTY INSURANCE COMPANY, to me personally known to be the individual and officer described in and who executed the preceding instrument, and she acknowledged the execution of the same, and being by me duly sworn, that she is the said officer of the Company aforesaid, and that the seal affixed to the preceding instrument is the seal of said Company and that the said seal and the signature as such officer was duly affixed and subscribed to the said instrument by the authority and at the direction of the Company. _____ ........ ~ .... ---... --JI.. ◄ 8 ALISON DWAN NASH-TROUT ~ 1 NOTARYPUBllC-MINNESOTA ~ , My Comml11lon Expires ~ ' January 31, 2025 . . Notary Public I..,.. __ ....,. ___ -,..-___ """',..,.._...- I, the undersigned, Secretary of ATLANTIC SPECIAL TY INSURANCE COMPANY, a New York Corporation, do hereby certify that the foregoing power of attorney is in full force and has not been revoked, and the resolutions set forth above are now in force. Signed and scaled. Oated..._ __ 7-'-th __ day of __ o_ct_o_be_r_-2024 . I This Power of Attorney expires I January 31, 2025 Please direct bond verifications to surety@mtacunsuram;e com Kara L.B. Barrow, Secretary Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM25-3589FAC EXHIBIT D In-Use Off-Road Diesel-Fueled Fleet Regulation Requirements CARB implemented amendments to the In-Use Off-Road Diesel Fueled Fleets Regulations that apply broadly to all self-propelled off-road diesel vehicles 25 horsepower or greater and other forms of equipment used in California. More information about the requirements can be found at https://ww2.arb.ca.gov/our-work/programs/use-road-diesel-fueled-fleets-regulation Contractors are required to comply with the requirements of the In-Use Off-Road Diesel-Fueled Fleet regulations, including, without limitation, compliance with Title 13 of the California Code of Regulations section 2449 et seq. th rough out the term of the Project. The City is a "Public Works Awarding Body," as that term is defined under Title 13 California Code of Regulations Section 2449(c)(46). Accordingly, the Contractor must submit, with their pre-award contract documents, valid Certificates of Reported Compliance (CRC) for the Contractor's fleet, and for the fleets of any listed subcontractors (including any applicable leased equipment or vehicles). Failure to provide a valid CRC, will limit the city's ability to proceed with awarding this Contract. Contractor has an on-going obligation for term of this Agreement to provide copies of Contractor's, as well as all listed subcontractors. most recent CRC issued by CARB. Throughout the Project, and for three (3) years thereafter, Contractor shall make available for inspection and copying any and all documents or information associated with Contractor's and subcontractors' fleet including, without limitation, CRC, fuel/refueling records, maintenance records, emissions records, and any other information the Contractor is required to produce, keep or maintain pursuant to the Regulation upon two (2) calendar days' notice from the City. Cole Library Fire Alarm Replacement Page 12 City Attorney Approved 6/5/24 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM25-3589FAC EXHIBIT D (CONT.) IN-USE OFF-ROAD DIESEL-FUELED FLEET REGULATION CERTIFICATION Contractor hereby acknowledges that they have reviewed theCARB's policies, rules and regulations and are familiar with the requirements of In-Use Off-Road Diesel-Fueled Fleet Regulation. Contractor hereby certifies, subject to the penalty of perjury, that the option checked below relating to the Contractor's fleet, and/or that of their subcontractor(s) ("Fleet") is true and correct: □ The Fleet is subject to the requirements of the Regulation, and the appropriate Certificate(s) of Reported Compliance have been attached hereto. □ The Fleet is exempt from the Regulation under Section 2449.l(f)(2), and a signed description of the subject vehicles, and reasoning for exemption has been attached hereto. □ Contractor and/or their subcontractor is unable to procure R99 or Rl00 renewable diesel fuel as defined in the Regulation pursuant to Section 2449.l(f)(3). Contractor shall keep detailed records describing the normal refueling methods, their attempts to procure renewable diesel fuel and proof that shows they were not able to procure renewable diesel (i.e., third party correspondence or vendor bids). □ The Fleet is exempt from the requirements of the Regulation pursuant to Section 2449(i)(4) because this Project has been deemed an "emergency", as that term is defined in Section 2449(c)(18). Contractor shall only operate the exempted vehicles in the emergency situation and records of the exempted vehicles must be maintained, pursuant to Section 2449(i)(4). ~ The Fleet does not fall under the Regulation or are otherwise exempt and a detailed reasoning is attached to this certification. Name of Contractor: Accent Electronics d.b.a. Standard Electronics Signature: ~:7 Name: Brent Leclair Dusenb: Title: President Date: Cole Library Fire Alarm Replacement Page 13 City Attorney Approved 6/5/24 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 EXHIBIT E Contractor's Proposal PWM25-3589FAC 1.-Standard -Electronics Fire Alarm • Access Control • Intercommunication Systems • Security • CCTV • Data August 51h, 2024 Revised September 17°', 2024 BID QUOTATION Carlsbad Cole Library-Fire Alarm System Replacement -("After" Business Hours) To: City of Carlsbad Program Manager Scope: Fire Alarm: INCLUSIONS: EXCLUSIONS: ATTN: Charles Balteria Replacement for an existing Simplex Fire Alarm System: Silent Knight: Fire Alarm Replacement includes: • (1) #6808, Fire Alarm panel replacement • (1) #SSU00690, Document Box • (1) #TG-7FE-V, TelGuard-Dual Comm Cell Dialer • (1) #SK-PSlO, NAC Panel • (1) #5860R, Fire Alarm Annunciator • (64) #SK-PHOTO, Addressable Smoke Detectors • (1) #SK-HEAT-ROR, Addressable Heat Detector • (4) #SK-DUCT, Addressable Duct Detectors • (10) #SK-PULL-DA, Addressable Pull Stations • (2) #OSYSU-2-CRH, Potter Replacement Corrosion Resistant Tamper Switches (For OS&Y) • (4) #SK-MINIMON, Monitoring Modules • (7) #SK-RELAY, Addressable Relay Modules • (20) #SCRLED/#SRLED, Strobe Devices (USE WHITE DEVICES) • (12) #P2RLED/PC2RLED, Hom Strobe Devices (USE WHITE DEVICES) • (119) Demo of existing Fire Alarm Simplex Devices • (1) Demo of existing Fire Alann panel • Lift Rental for 1 device location • System drawings • Installation labor • Programming Includes tax, freight, labor, material & 3-year warranty. Quote valid for 90 days. Fire Alarm 4 sq. back boxes or any additional required conduit. Drawing any Architectural Backgrounds. (Customer to provide AutoCAD floorplans if none are available, we can draw them for an additional cost impact.) New Cabling is excluded and if new cabling is required this would have an additional cost impact on the project. THIS DID MUST BE MADE AN EXHIBIT IN THE CONTRACT DOCUMENTS 613 W. Main St., El Cajon, CA 92020 -8, C-7. C-10, C-16 Lie #590876 Exp March 31. 2026-(619) 596.9950 Ph (619) 596.8850 Fx Cole Library Fire Alarm Replacement Page 14 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM25-3589FAC •• -Standard -Electronics Fire Alarm • Access Control • Intercommunication Systems • Security • CCTV • Data Fire Alarm System Replacement Bose Cost: City of Carlsbad Permit Fees Cost: Fire Alarm System Performance Bonding Cost: Fire Alarm System Replacement Total Cost ("After" Business Hours): Respectfully Submitted, ~4?1--1--- Nathan Edwards Standard Electronics Cole Library Fire Alarm Replacement Page 15 $1,593.00* 543,074.00* Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 6808 Intelligent Fire Alarm Control Panel with Communicator The 6808 features a built-in SLC circuit, four output circuits, dual-line DACT, powerful software features, and connectivity for up to 17 panels. The 6808 is the latest intelligent addressable FACP [Fire Alarm Control Panell from Silent Knight and is a direct replacement for the 5808 FACP. The 6808 has one SLC (signaUng line circuit) loop for connecting addressable detectors, which can support99 System Senso~ SK sensors and 99 SK modules or 127 Hochik~ SD devices per loop. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable.A designated panel is ccnfigured as the communicator far all panels in the link far convenient single-point communications. The built-in digital alarm communicator/transmitter (DACTI is dual technology, IP and POTS. The POTS transmits system status (alarms, tmubles, AC loss, etc.) to a Central Station via the public switched telephone network The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available. The 6808 has four onboard output circuits that can be configured as notification outputs or auxiliary power. There are four types of Aux power available: door holder, constant power, resettable power and sounder sync power. The 6808 also has farm-C trouble relay, and two programmable form-C relays, along with powerful features such as drift compensation, pre- trouble maintenance aler~ a built-in sensor test to comply with NFPA 72 calibration testing requirements.and a calibration trouble alert. The 6808 supports a varletyof devices, including 6860, 5860, or6855 remote annunciators, 5824 seria Vparallel printer interface modules (for printing system rePorts), 5895XL power modules, and SK, SWIFT"' wireless, or SD devices. FEATURES AND BENEFITS Complies with UL 86410th Edition Built-in support for up to 99 IOP/SK detectors and 99 IOP/SK modules or 127 SD SLC devices Four output circuits (3 amps max) for NAC outputs or auxiliary power Selectable strobe synchronization for Amseco•. System Sensor. Wheelock". and Four line LCDdisplaywith 20characters per line Built-in USS interface forquicl:. and easy programming JumpStart~ auto programming reduces installation time • 13 prgsat notification cadence patterns (including ANSle 3.41) Gentex• dev·,ces Allows up to 20 SBUS devices 250 so!tware zones and 250 outp•Jt groups • Two programmable r&lays and one fi>·ed for flexible design opfrons trouble relay Built-in dual phone line, digital alarm communicator/ transmitter (DACllwith IP and optional cellular technologies Cole Library Fire Alarm Replacement • Convenient field-upgrad~able firmware • Supports up to tour SWIFT wireless gateways which can foster up to 49 wireless devices e,ach Page 16 PWM25-3589FAC • Connectivityforuptol7 sites Netwo,l..card allow, copper network connection with a multi-mode or single- mode fiber connection • Programmable date setting for Ocyl'!ght Savings Time History fil,:,with l .ro:J event capacity Can be surface or f!ush-mounted Honeywell r!!Sll.ENT' li,;:ilJ<NTGHT Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 USER INTERFACE LED INDICATORS • GeneralAlarm(Red) • Supervisory(Yellow) System Trouble (Yellow) • System Silenced (Yellow System Power(Green) KEYPAD • 12-keynumeric pad • Acknowledge • Alarm Silence System Reset • F1-F4 Programmable Function Keys PROGRAMMING The 6808 system offers several options to simplify and expedite programming. JumpStart auto programming minimizes programming required to start a neN system. The built-in keypad, or the remote annunciators give on-site access to current system programming. System programming can also be accomplished using the Windows•-based Honeywell Fire Software Suite (HFSS). ORDERING INFORMATION 6808: Addressable fire alarm control panel, red COMPATIBLE SBUS DEVICES 6860: 4x't0 LCD remote fire annunciator with four programmable buttons, red 5860: 4x20 LCD remote fire annunciator, gray 5860R: 4x20 LCD remote fire annunciator, red 6855: 4x20 LCD remote fire annunciator, red 5865-3: LED annunciators can display up to 30 LEDs (15 red and 15yellow) 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). Key switches for silence and reset, and a system trouble LED 58B0: LED 1/0 module with 40 programmable LED outputs and eight supervised dry contact inputs 5883: Relay interface. Provides 10 Form C relays 5824: Serial/Parallel printer interface module for printer connection SK COMPATIBLE ADDRESSABLE DEVICES Note:SKand SD devices cannot be mixed in the same system. Refer to the Device Compatibility Document and SLC Wiring Manual for more information. SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T: Reflected beam smoke detector with testfeature OSI-RI-SK: Reflected beam smoke detector, SK protocol SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended air speed range SK-FIRE-CC: Four criteria fire and carbon monoxide detector Page 2 of 4 -351608:D • 5/22/2023 Cole Library Fire Alarm Replacement PWM25-3589FAC SK-FIRE-CO-W: Four criteria fire and carbon monoxide detector, white SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-W: Fixed thermal detector (135°F), white SK-H EAT-ROR: Rxed rate af rise detector SK-HEAT-HT: Ftxed high temperature thermal detector (190°F) SK-HEAT-HT-W: Fixed high temperature thermal detector (190°F), white SK-HEAT-ROR-W: Fixed rate of rise detector, white SK-ISO: Fault isolator module SK-Ml NIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10-input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-W: Photoelectric smoke detector, white SK-PHOTO-R: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric detector with remote test capability, white SK-PHOTO-T: Photoelectric smoke detector with fixed thermal heat (135°F) SK-PHOTO-T-W: Photoelectric smoke detector with fixed thermal heat(135°F), white SK-PTlR-W: Multi criteria photoelectric smoke detectorwith thermal 135°F fixed temperature, white SK-PULL-SA Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/monitor module SK-ZONE:Addressablezone interface module SK-ZONE-6: Six zone interface module SK BASES 8210LP: 6" mounting base 8501: 4· Flangeless mounting base 8200S: Intelligent sounder base 8200S-LF: Low-frequency intemgent sounder base 8224R8: Relay base 822481: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES Note: SK and SD devices cannot be mixed in the same system. SD505-6AB: Addressable 6" base SD505-61 B: Addressable 6' short circuit isolator base S0505-6RB: Addressable 6" relay base SD505-6SB: Addressable 6" sounder base S0500-AI M: Addressable input module (switch input) SD500-ANM: Addressable notification module SDSOO-ARM: Addressable relay module SD505-DTS-K: Remote test switch/LED indicator for the SD505-DUCTR SD505-DUCT:Addressable Duct Smoke Detector SD505-DUCTR:Addressable Duct Detector housing with relay base Page 17 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 SD505-H EAT:Absolute temperature heat detector. Trip point range from 135°F-150"F CO"C-37°C) SD500-UM: Addressable Line isolator module SD500-MIM:Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module SWIFT WIRELESS DEVICES Note: SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSK-WGl:Wireless gateway WSK-PHOTO: Wireless photoelectric smoke detector with B501 W base WSK-PHOTO-T: Wireless photoelectric smoke detector with fixed thenmal detection (135°F) and 8501W base W-SYNC: Wireless sync module WSK-HEAT:Wireless, fixed heat detector (135°F) with B501 W base WSK-HEAT-ROR: Wireless rate-of-rise heat detector and B501 W base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module WSK-PULL-DA: Wireless pull station WAV-CRL, WAV-CWL: Wireless AV bases W-USB:Wireless USB radio/antenna dongle that plugs intotheUSB port of a PC running SWIFT Tools SWIFT Tools: Programming and diagnostic utility for the wireless gateway and devices. Available for download from www.farenhyt.com SYSTEM EXPANDERS 5895XL: 6A power supply with six Flexput circuits and two Form C relays 5496: 6A NAC power expander with four power-limited output circuits Page 3 of 4-351608:D • 5/22/2023 Cole Library Fire Alarm Replacement PWM25-3589FAC OPTIONAL COMMUNICATORS HWF2A-COM: Digital Cellular Fire Alarm Communicator and Internet Panel. AT&T HWF2V-COM: Digital Cellular Fire Alarm Communicator and Internet Panel, Verizon IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-IP-2: Remote reporting via the Internet. Requires a Visor ALARM• receiver at the centre I station MISCELLANEOUS ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the 6808 SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber-Optic Multi Mode, transmitter and receiver SK-FSL: Fiber-Optic Single Mode RBB: Remote battery box accessory cabinet SK-SCK: Seismic compliance kit to fasten batteries to the fire panel SOFTWARE SOLUTIONS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows~-based software system configuration tool to create a detailed bill of material CBOM) and battery calculations HFSS: Honeywell Fire Software Suite provides remote and local panel programming, detector status, event history and additional data. Databases can be uploaded/downloaded via the panel's USB port using a flash drive. Requires a PC running Microso~• Windows". Page 18 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 6808 TECHNICAL SPECIFICATIONS SYSTEM CAPACITY lntetugent Signaling Line Circuits: 1 Addressable device capacity: 198 CSK) or 127 (SD) Programmable software zones: 250 Output circuits: 4 (expandable) SBUS Devices: 20 (12 annunciators. 8 LED modules) ELECTRICAL AC Power: 120VAC,60Hz. 3.3A Standby Current: 190 mA Alarm Current: 250 mA output Circuits: Terminal block provides connections for (four Class B or two Class A) NACs or auxiliary power. Power-limited. supervised circuitry. Maximum current per circuit: 3 A. Cannot exceed 6A total for all circuits. End-of-line resistor: 4.7k ohm, \I, watt for Class B NACs Communication Loop: Supervised and power-limited. Class A or Class B. 32VDC. 150mA Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.5 A@ 27.4 VDC (resistive), Form C Battery: Cabinet holds maximum of two 18 AH batteries Battery Charger Capacity: 17-55 AH PHYSICAL Dimensions: 16.4"Wx26.4" H x4.1" D (41.66cm Wx67.06cm H x 10.41cm D) Weight: 45 lbs. (20.4 kg.) Color: Reel Honeywell Silent Knight 12 Qinlon'lille Road Northford, CT 06472-1610 203.464.7161 www.~'.entknight.com Cole Library Fire Alarm Replacement TEMPERATURE AND HUMIDITY RANGES This system meets N FPA requirements for operation at0-49oC (32-120°F)andata relative humidity 930/o ± 2% RH [non- condensing) at 32°C ± 2°c (91'.l"F± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore. it is recommended that this system and its peripherals be Installed in an environment with a normal room temperature of 15-27°C/60-80"F. NFPA STANDARDS The 6808 complies with the following NFPA 72 Fire Alarms Systems requirements: NFPA 13, NFPA 15. NFPA 16, NFPA 70, NFPA 72 Central station: remote Signaling; Local Protective Signaling Systems: Auxiliary Protected Premises Unit Water Deluge releasing service. Suitable for automatic. manual waterflow. sprinkler supervisory (DACT non-coded) signaUng services AGENCY LISTINGS AND APPROVALS UL Listed: S2766 CSFM: 7165-05590502 FDNY: COA# 2023-TMCOAP-001168- RENL FM Approved Seismic: (CA) VMA-45894-05C 351608 I D I 05-23 C:2)23 !-ione)'Wi!ll lnte,retbnal Inc. Page 19 PWM25-3589FAC 11:i~eyr;e:l , JumpS:;rt , s:,em Knight . SWlfl . a,rJ System SensJr ace reg:st8red tracleri-1a·~s of Honeywcll lmcrna•.io~al Ire. Amseco is a registered traden1ack of Potter Electr" c S g., a: Cor10a'ly. LLC. G•,·nex· s a regis;e·ej troderriurk ot Gentex Coroo•aror. 1-1:>chiki :s a regis'.ered trademark of Hoch.ki Corpo·acio11. WJ·ee ock· is a trade1nark of Coooer r echnolog'es CofYl:Ja'ly. ANSI ·s a ·e;Jis~a,.ed :~Jdern~rk of :r~e Ar-,crica,i l~3\ional S'.YdardG 1,1stia,te. Inc. Visocf,LAHM' is a •egiste·ed trademark of me Te'.dat Corporal·on tv'icn.Joofl dnd Vlindovi.1:; a:g regi£tered uade~a·Ks of tvl crosoft Co rp·Jr)t o~. l 1· i0 d::icume~t is no· ·rtenrlecl t:J hr usP.d for insra'.lation ntira'.'.>ses \Ve try::, keen our product 'nfow,ation up-to-dat~ and ascu rat 0. We ca" not cove .. all specific upolicJfo.,::-or a~ti:::io:1t~ a .. requireJY1ents. A,l specif:cations are sub; ec: :o chang 2 witnout ro~:ce. Country of or'~in: USf, Honeywell t?.!I SILENf. U J<NIGHT Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 a SILENT KNIGHT ' by Honeywell PWM25-3589FAC 5860 Remote Annunciator Bring the power to control an lntelllKnlght fire alarm control panel to every area within your faclllty Now you can operate and program your lntelliKnight system from up to twelve locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the lntelliKnight panel's built-in annunciator. The BO-character display and ergonomically designed keypad allow for simple and error-free system operation. All operations-including reset, silence, detector status checking, fire drill, and programming-are Identical. Access to the system is through a fireflghter's key or an access code. For security, a special installation code Is needed for programming functions. The 5860 connects to the lntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description Features Include an 80-<:haracter backlit LCD providing easy-to- understand system messages. The annunciator is ergonomically designed with over-sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator endosure can be surface or flush mounted. A trim ring kit is available for surface mounting. Features • 80-<:haracter backlit LCD display (4 lines with 20 characters on each line) • Tactile and audible feedback • Accepts user codes or fire fighter's key • Larger keypad buttons for system reset and silence • Install up to twelve 5860s per 5820XL/EVS or 5808 system • Install up to eight 5860s per 5700 system Cole Library Fire Alarm Replacement • Available in red or light gray • Support for simultaneous use of multiple 5860s • RS-485 interface to panel • Operation and appearance is identical to 5860 bullt-in annunciator • On-board piezo sounder audibly indicates alarms, troubles, and supervisories • Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions • Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) • UL listed, complies with NFPA 72 • CSFM approved Electrical Specifications Operating Voltage: 24 voe Standby Current: 20 mA max Alarm Current: 25 mA Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Mechanical Specifications Physical 9.1" W x 7.4" H x 1.5" D (23.1 W x 18.8 H x 3.8 D cm) Shipping Weight: 2.8 lbs (1.3 kg) Color 5860R: Red 5860: Gray Page 20 5860 Environmental Operating Temperature: 32°F - 12o•F (o•c -49"C) Humidity: 10% -93% non- condensing Compatibility The 5860 ls compatible with the following FACP's: • 5820XL Addressable Fire Control Panel • 5820XL-EVS Fire Control Panel with Emergency Voice System • 5808 Addressable Fire Control Panel • 5700 Addressable Fire Control Panel PN 350224 Rev G © 2014 Honeywell International Inc Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 5860 Remote Annunciator Engineering Specifications PWM25-3589FAC The main control must have a built-in annunciator and must support up to 12 remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have ldenlical functionality and operation as the built-in annunciator. All annunciators must have an SO-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. SBUS SS60 Wire Runs Up lo 6000 Feel From FACP 6860 • Up to 12 liB60s Per IFP-100/ECS or IFP-1000/ECS System • Up ta Eight 5860s Per 5700 System 11860 Co"'14tible lnleltiKnight FACP Listings Ordering Information NFPA 72; UL Listed; CSFM 7170-0559: 135; MEA429-92-E Vol. IX: 5860R Remote Annunicator four line LCD annunciator with 20 characters per line. Red FM Approved ~ SILENT ~KNIGHT by Honeywell 5860 Remote Annunciator four line LCD annunciator with 20 characters per line. Gray Accessories 5860TR 5860TG Red Trim Ring for surface mounting Gray Trim Ring for surface mounting This docurrent Is not Intended to be used ror Installation purposes. We try to keep our product information up-to-date and accura1a. We cannot cover all specific applicaticns or anticipata all requirements. All specifications are subject to change wtthout notice. For more Information, contact Silent Knight 12 Cllntonvllle Road, Northford, CT06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.•llentknlght.com ...... Assembled In America Cole Library Fire Alarm Replacement Page 21 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM25-3589FAC INTELLIKN1,:;HT ACCE:::: ,)RY > SK-Relay - lntelllgent Relay Module The SK-Relay Module is intended for use in intelligent, two-wire systems where the individual address of each module is selected using the built in rotary switches. For more information about the lntelliknight sy6fem, or to locate you nearest source, please call BDD-328-0103 or in Connecticut, call (203) 484-7161. Description The SK-Relay is an addres.sable relay module for u.se with Silent Knight lntelliKnight .series fire alarm control panels (FACPs). The SK-Relay allow.s a Silent Knight FACP to .switch discrete confacf8 by code command. The relay contain.s two i.solated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The SK-Relay contacf8 can be used for virtually any normally open or normally closed application. Each SK-Relay is programmed with a unique .signaling line circuit (SLC) loop address. When an event occur.; that controls the SK-Relay, the SK-Relay relay is triggered by the FACP. Installation Features • Two sefs of Form C contact.s • Rotary addre.s.s .switches for fa8t installation • Contacts are rated for a variety of amps (see Specifications) • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Relay programming is completely flexible-can be mapped to zone conditions • Polling LED visible through the cover plate • Attractive ivory cover plate • SEMS screws for easy wiring • UL Listed The SK-Relay mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Senso~ PN SMB500) is available from Silent Knight Compatibility The SK-Relay is compatible with the following lntelliKnight FACP's: 5700 5808 5820XL • SILENT KNIGHT byHoneyweH Cole Library Fire Alarm Replacement Page 22 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM25-3589FAC Model SK-Relay To Next Device + 4--------If Any Wiring to Terminals 3 -9 Is Not Powitr Limited, the CBSO0 Barrier is Required. The CBSOO Includes a Non.Power Limited Label, Which Must Be Placed Over the Power Limited Terminal Information on the Name Plats Label. Relay CG NormallyC NormallyO RelayC NormallyC Module Don Not Supervise Controlled Circuits Speclfi cations Physical Height: 4.65" Wi<lth: 4.25" Depth: 1.1" Shippir11;1 Weight: 6.3 02 (196 g) Electrical Operating Voltage: 15-32 voe Current Draw: 6.5 mA max (LED on) Operating Current: 230 µA (LED flashir11;1) <:lirecl poll 255 µA (LED flashir11;1) group poll -From Compatible FACP "' or Previous Device Normally Open 1 Wiring the SK-Relay Module End-of-Line Resistanoe: not use<:I Stan<:lby Current: 300 µA max @ 24 VD C (one communication every 5 sec with LED enabled) LED Current: 5.5 mA(wilh LED lalehed on) SLC Loop Resistance: 40Q max. Relay Contact Rat In gs 3.0A@ 30 voe resistive 0.9A@ 110 voe resistive 0.9A@ 125 VAC resisti\re O.SA@ 125 VAC inductive (PF= .35) 0. 7A@ 75 VAC inductive (PF~ .35) . SILENT KNIGHT by Honeywell To~ document is not intendbd to Ile usbd for mstaJlalrc,n purposes. We lri to koop our pro,duct Information Ul)-to--dateand accurate. Wecannotcover all specific applications or anticipate all requirements. All specifications are subjact b> chang& without notice. For more Information, oontact SIient Knight 12 Clintonville Road, North ford, CT 06472-1610 Phone: (300) 32:a-010S, Fax: (203) 434-7113. www.sllentknlght.com MADE IN AMERICA F0RM#350127 Rev A © 2009 Hon<!lywell lnternatie>nal Inc. Cole Library Fire Alarm Replacement Page 23 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 I r,?!I SILENT ~KNIGHT by Honeywell PWM25-3589FAC l'HELLIKtll\.>H r ACCESSORY --+> SK-DUCT Intelligent Air Duct Smoke Detector I Detect smoke in air handling systems and air handling equipment with Silent Knight's addressable duct smoke detector The SK-Duct Intelligent air duct smoke detector is used with SK-PhotoR (included) for detecting smoke and products of combustion present in air moving through an HVAC air handling system. When smoke is detected in a duct, the unit communicates the condition to the lntelliKnight control panel. The panel, in tum, depending on programming and wiring, turns off fans, blowers, and other devices. The dud housing allows for mounting of SK-Relay addressable relay module. Now there's even more power and flexibility available to the lntelliKnight family of products! Description J2 < The Model SK-Duct Air Dud Smoke Detector utilizes photoelectric technology for the detection of smoke. It provides early detection of smoke and products of combustion present in air moving through HVAC ducts in Commercial and Industrial applications. The SK-Duct is in a heavy duty gray steel back box with a clear cover. It features a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. It installs quickly and easily. The unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4000 feet per minute, temperatures of -4°F to 158°F. and a humidity range of D to 95 percent (non-condensing). Features • Versatile mounting options: square or rectangular configuration New Cover tamper signal LED alarm indication and communication on sensor head • Detects and limits the spread of smoke Rugged steel back box with clear plastic cover • Easy to clean • Large terminal connection screws • Transparent cover for convenient visual inspection • Patented sampling tube installs from front or back of the detector with no tools required • Available space within housing to accommodate mounting of relay module • UL listed Specifications Physical (Rectangular): 14.38 in (37 cm) Length; 5in (12.7 cm) Width; 2.5 in (6.6 cm) Depth (Square): 7.75 in (19.7cm) Length; 9 in (22.9cm) Width; 2.5 in (6.35cm) Depth Weight: 1.6Ib (0.73kg) Environmental Operating Temperature: -4°F -158°F (-2o•c -1o•ci Humidity: 0% -95% (non-condensing) Air Velocity 100 to 4000 fl/min (0.5 -20.3 m/sec,) Electrical (using SK-Photo or SK-PhotoR) Operating Voltage: 15-32 VDC Standby Current Alarm Current: 300 µA @ 24 VDC max. 6.5 mA @ 24 VDC max (with LED on) Cole Library Fire Alarm Replacement Page 24 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM 25-3589FAC lt<TELLIKNIGHT ACCESSORY Model SK-DUCT Air Duct Smoke Detector/ Engineering Specifications The air duct smoke detector shall be a SK-Duct photoelectric duct smoke detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velocities of 100 fl/min to 4000 fl/min (0.5 m/sec to 20.32 m/sec). The unit shall be capable of providing a trouble signal in the event that the sensor oover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS151KEY remote test station. Terminal oonnections shall be of the strip and clamp method suitable for 12-18AWG wiring. The unit housing shall be capable of mounting a relay module. Ordering Information SK-Duct SK-Photo SK-PhotoR SK-Relay Accessoriest DST1 DST1.5 DST3 DST5 DST10 DH400OE-1 ETX RA1002 DCOIL RTS151 RTS151KEY Intelligent non-relay duct smoke detector M02-04-00 Test Magnet Addressable Photo Detector P48-21-00 Replacement End Cap for Metal Sampling Tube Addressable Photo Detector with remote test capability (Included with SK-Duct) APA151 Remote annunciator with piezo alarm Addressable Relay Module, must be added if relay function is required, (fits in housing) Metal Sampling Tube Duct Width up to 1' Metal Sampling Tube Duct Widths 1' -2' Metal Sampling Tube Duct Widths 2' -4' Metal Sampling Tube Duct Widths 4' -8' Metal Sampling Tube Duct Widths 8' -12' Weatherproof Enclosure Metal Exhaust Tube Duct width 1' Remele LED Annunciator Duct accessory coil, required if using with SK-Photo and not SK-PhotoR (included) with SK-Duct Magnetic Remote Test station Key-Activated Remote Test station Important Notes: • The use of either RTS151 or RTS151 KEY requires the installation of an accessory coil, DCOIL, sold separately. Please refer to the SK-Duct installation instructions for more information • The RTS151/RTS151KEY test coil circuit requires an external 24VDC power supply which must be UL listed. SILENT KNIGHT This document is not intended to be used for installation purposes. We try to keep our product .iformation up-l<Hlate and accurate. We cannot cover all specific applicafons or anticipate all raqlimments. All specifications MADE IN AMERICA FORM# 350122 Rev D • by Honeywell are subject to change without notice. For more lnformeUon, contact SIient Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203),484-7118. www.sllenlknlghl.com Cole Library Fire Alarm Replacement Page 25 @ 2010 Honaywell lntemational Inc. Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM25-3589FAC INTEL~IKtJIGHl ACCESSORY ~ SK-Photo and SK-Photo-T Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector and the SK-Photo-Tis a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight lntelliKnight Fire Alarm Control Panels (FACPs). For more information about the lntelliKnight system, or to locate your nearest source, please call 800-328-0103 or in Connecticut, call (203) 484-7161 . Des SK-Photo and SK-Photo-T are plug-in type smoke sensors that combine a photoelectric sensing chamber with addressable analog communications. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. SK-Photo and SK-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the SK-Photo-T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. Features • Sleek, low-profile design Base Included Reliable analog communications for trouble-free operation • Age resistant polymer housing • Dual electronic thermistor design on the SK-Photo-T Superior EMI resistance for reliability Simple field cleaning for code compliance Variety of mounting options to meet any application Dual LED indicators for 360° visibility Detector transmits signal to indicate maintenance is required Optional remote LED annunciator (System Sensor® PN RA100Z) Cole Library Fire Alarm Replacement • Plug-in mounting provides ease of installation • Tamper-proof feature available on mounting bases • Listed for use in duct applications • Rotary address switches for fast installation UL Listed • FM Approved Specifications Physical Height: 2.0" (5.0 cm) Diameter: 4.1" (10.4 cm) Shipping Weight: 5.2 oz. (147 g) Electrical Operating Voltage: 15-32 voe Standby Current: 300 µA@ 24 VDC Maximum Alarm Current: 6.5 mA@ 24 VDC max (with LED on) Environmental Operating Temperature SK-Photo: 32° -120"F (OOC -49°C) SK-Photo-T: 32° -100°F (0°C -38"C) Humidity: 10% -93% non-<:ondensing Other Ratings SK.Photo-T Thermal: Fixed temperature set point 135°F (57oC) Velocity: 0 -4000 fpm (0 -20 m/sec) SK-Photo Insect Screen Hole Size: 0.016" (0.41 mm) nominal Page 26 SK-Photo {Base included) Compatibility The SK-Photo and SK-Photo-Tare compatible with the following lntelliKnight FACPs: 5700 5808 5820XL SK-Photo and SK.Photo-Tare compatible with the following detector bases: B210LP B501 B501BHT-2 B224RB B224BI (included) 6" base 2wire base Temporal base Relay base Isolator base B501 BH-2 Sounder base ~SILENT ~ KNIGHT by Honeywell Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 INTEI LIKNIGHT ACCESSORY Model SK-Photo and SK-Photo-T Intelligent Pho~electric Smoke Sensors '\/ Engineering Specifications PWM25-3589FAC The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knighfs lntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B21 OLP (included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. f,!!!SnENT ~KNIGHT 17,>tloneywel RA11QZ(Opllollll) This document is not intended to be used for installation purposes. We try to keep our product Information up-tCHlate and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information. contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103. Fax: (203)◄84-7118. www.silentkni\tllcom Cole Library Fire Alarm Replacement Page 27 MADE IN AMERICA FORM# 350118 Rev A, © 2009 Honeywell lntemational Inc. Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 ~SILENT ~ KNIGHT by Honeywell PWM25-3589FAC l'JTHLl,<fsl<,1-T /ICCESSO"''( ~ SK-Minimon Intelligent Mini Monitor Module The SK-Minimon addressable mini monitor modules for use with Silent Knight lntelliKnight fire alarm control panels (FACP). The SK-Minimon is designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. For more information about the lntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description 7 The SK-Minimon is an addressable monitor modules for use with the lntelliKnight fire alarm control panels (FACPs). The SK-Minimon acts as an interface to contact devices, such as waterflow switches and pull stations. The SK-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions The SK-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. Features • Single contact monitor • SK-Minimon support for Class B (Style B) contact monitor wiring • Small and lightweight size allows for flexible mounting options • Rotary address switches for fast installation • UL listed Cole Library Fire Alarm Replacement Specifications Electrical Standby Current: 400 uA max @ 24 VDC with comm. Voltage Range: 15 -32 VDC SK-Minimon Compatibility The SK-Minimon is compatible with the following lntelliKnight Systems: 5820XL 5808 End of Line Resistance: 47 k Ohms 5700 Physical Dimensions: 2.75" W x 1.3" H X 0.5" D Weight: 1.2 oz (37 g) Environmental Operating Temperature: 32°F -12o•F (o•c -49°C) Humidity: 10% -93% non-condensing Page 28 5600 (Rev 2.0 or higher) SK-FFT Approvals UL approved CSFM FM Approved Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM25-3589FAC nHELLIKNIGHT ACCESSORY SK-Minimon Intelligent Monitor Modu/ Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable monitor modules Silent Knight SK-Minimon. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight FACPs. The device shall be capable of Styles A and B supervised wiring to the load device. The SK-Minimon shall be installed inside a single gang junction box directly behind the monitored unit. Compatible FACP . SILENT KNIGHT by Honeywell ~~~)! 111~1 la 7 I TENS ADDRESS LOO? D Wiring the SK-Minimon This document is not intended to be used for installation purposes. We try to keep our product infonnalion up-to-date and accurate. We cannot cover all specific appllcattons or anticipate all requirements. All specifications ere subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Norlhford, CT 08472-1610 Phone: (800) 328-0103, Fax: (203)484-7118. www.silentknlght.com Cole Library Fire Alarm Replacement Page 29 Other Devices MADE IN AMERICA FORM# 350133 Rev C © 2011 Honeywell International Inc Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 L-Series and L-Series with LED Indoor Selecta.ble Horns, Strobes and Horn Strobes System Sensor L -Series and L -Series with LED audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • LED technology provides lower current draw • Digital Voltage Meter (DVM) diagnostic test points for Horn Strobes and Strobes • Cc,mmon aesthetics across thG L-Series platform • Standard and compact sizes • Tamper-resistant construction • Field-selectable canoela settings on wall unis: 1-5, 30, 75, 95, 110, 135, and 185 • Fleld-selactable camela settings on ceiling unns: 15, 30, 75, 95, 115, 1.50, and 177 • Rotary switches for oardela, tone am volume selections • Mounting plate provides plug-in design for easier irstallation and shorting springs to check wiring continuity • Electrically compatible with legacy SpectrAlert, SpectrA/ert AdVance and L-series devices • Synchronization through use of UL approved power supplies1hat support System Sensor sync protocol or System Sensor MDL3 Sync Module • Horns, Strobes and Horn Strobes listed for wall or ceiling use Agency Listings --I c@us @ @ 1:2> USTEI ISfED urra Horn strobe!. """' t-brns: 3:J.67072 ="™"" andSIJObi,; II S401 1 FM23FPUS019S =--$51i?,Sit011 11:f;,ltfil~ Cole Library Fire Alarm Replacement I t . PWM25-3589FAC The System Sensor l•leltes and L•Seltes with LED platform offers the rnost versatile and easy-to-use line of horns, strobes, and horn strobes in the industry wtth lower curren1 draw and modem aesthGt~s. LED lighting tecr,r<liogy offers significantly lower current draw compared to older Xenon bulbs across a full candela range. This improves design 1Iexibility for noti1ication appliance circuits (NACs) while also reducing power supply requirements allowing 1or simpler ard lower cost installations. FleXJble design options moot virtually any application requirement: wall or ceiling rnounl, standard or compact sizes, red or wMe color choices, bezel kns for alternate markings and languag9s, and LED color lenses for distinctive visual signaling. In addition, Installers can easily adapt devices using field selectable candela, lone and volume settings using rotary switches. The L-Series and L-Series with LEO line is developed to sirnplrty inslallatlon. All devices feeture plug-in designs with minimal intrusion into the back box, making installations 1ast and foolproof while virtually eliminating costly and time-consuming ground faults. The universal mounting plate includes an onboard shorting spring, so Installers can test wiring continuity before the device Is installed. In addition, the System Sensor L-Series with LED notification appliances offer a new diagnostic test point feature that allows you to measure de\rlce voltage with a digital voltage meter (OVM) without rerrK:>ving the appliance from the wall or ceiling. The OVM test points are discreetly located on the face of the noti1ication appliance which enable fastertroubleshooting ard end of line (EOL) voltage checks while greatly reducir,,;i thG risk of misplacing or damaging appliances during troubleshOCting. Page 30 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM25-3589FAC L-Series and L-Series with LED Specifications Physical/Eloctrical Spoc1!1cations Slandard 0pera11n11 Tomponttur• Humidity Range Strobe Flesh Rate Nominal Voltage, LED Strobel and Horn Strobes Nominal Voltage, Homa Operating Voltage Range, LED Strobes and Hom Strobes Operating Voltage Range, Homa lnputTermlnalWlre Gauge 32°Fto 120°F(D'C to 49'CJ 10 to 93% non-condensing 1 flash per second Regulated 24 VIX Regulated 12VOC or regulated 24 DC/FWR 16 to 33 V (24 V nominal) Bio 17.SV(12Vnominal)or 16 to 33 V (24 V nominal) 12to 18AWG ULJULC Current Draw Data, Hom Tones, and Sound Output Data UUULC Maxmimum Strobe Current Draw (mAJ UUULC Maxmimum Horn Current Draw {mA RMS) Candela 16-33Volts &-17.5Volts 16-33 Volta Rating Wall Celling Sound Pattern dB DC DC FWR Candela 15 18 18 Range 30 22 22 Teml)Oral High 39 44 54 Temporal Low 28 32 54 75 70 70 95 75 75 110 85 115 90 135 105 150 110 177 115 185 120 Non-Tempora I High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Ternporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Ceded High 43 47 54 3.1 KHz Coded High 42 43 54 UUULC Maximum Horn Strobe Current Draw (mA) and Sound Output (dBA) current Draw (mA RMS), Hom Strobe, Sound Candela Range (15-185 cd) Output (dBA) 16-33 Volta 16·33V Switch Volume 15cd 30cd 75cd 95cd 110cd 115cd 135cd 15Dcd 177cd 185cd DC Pos. Sound Pattern Setting WALL CEILING WALL CEILING CEILING WALL , Temporal 3 High 35 38 87 92 94 120 ,ag 189 190 190 87 2 Temporal 3 Low 35 38 87 92 94 120 135 135 145 145 79 3 Non-Temporal High .so 52 87 92 94 120 127 127 135 135 87 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 79 5 3.1 KHz Temporal 3 High 35 38 87 89 91 115 155 155 165 165 86 6 3.1 KHz Tgmporal 3 Low 35 38 87 89 91 115 128 130 135 135 80 7 3.1KHz Non-Temporal High 40 42 87 89 91 115 125 125 135 135 86 8 3.1KHz Non-Temµ,rai Low 35 38 87 89 91 115 120 120 130 130 80 Cole Library Fire Alarm Replacement Page 31 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 L-Series with LED Dimensions: Wall-Mounted E ui ment A0817-00 Compact Strobe, Horn Strobe for Wall strobes, Hom Strobes for Walle .-,00,47-00 Compact Horn lr' --j tr .... tlUllffl ~I 12111'1 ' ~ Hom PWM25-3589FAC A0567-0l Compact Surface Mount Back BCIJC forWalls (SBBGRL,SBBGWL) Surface Mount Back Bo,c for Wallo ( SBBRLJSBBWL) L-Series with LED Dimensions: Ceiling-Mounted Equip,_m_en_t ___________ _ Strobes and Horn Strobec lorCelllngs Cole Library Fire Alarm Replacement 207' (52.6rrrn) 125' (316rm, "'"""° Page 32 I-25' 1 I (8'1 mn1 0 Surface Mount Ba,;k Box for C..llilgo (SBBCRL, SBCWL) AVOS91$-01 • 1003®23 • Page 3 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 L-Series with LED: Ordering Information Model Description L-Serl• with LED Ham Streb• P2RLED 2-Wira, Hom Strobe, Wall, Red P2RLED-B P2WLED P2WLED-B P2GRLED P2GRLED-B P2GWLED P2GWLED-8 P2RLED-f' P2WLED-P P2RLED-SP P2WLED-SP PC2RLED PC2RLED-B PC2WLED PC2WLED-B 2-Wire, Horn Strobe, Wall, Red, BIiinguai 2-Wire, Horn Strobe, Wall, White 2-Wrre, Horn Strobe, Wall, White, Bilingual 2-Wrre, Compact Horn Strobe, Wall, Red 2-Wire, Compact Horn Strobe, Wall, Red, Bilingual 2-Wrre, Compact Horn Strobe, Wall, White 2-Wire, Compact Horn Strobe, Wall, White, Bilingual 2-Wire, Horn Strobe, Wall, Red, Plain 2-Wire, Horn Strobe, Wall, White, Plain 2-Wire, Horn Strobe, Wall, Red, FUEGO 2-Wlre, Horn Strobe, Wall, White, FUEGO 2-Wire, Horn Strobe, Ceiling, Red 2-Wir&, Horn Strobe, C&iling, Red, Bilingual 2-Wire, Horn Strobe, Ceiling, White 2-Wire, Horn Strobe, Ceiling, White, Blllnaual L-Serles with LEO Strobes SRLED Strobe, Wall, Red SRLED-B SWLED SWLED-B SGRLED-B SGWLED SGWLED-B SRLED-P SWLED-P Sf1LED-SP SWLED-CLA- ALERT Strobe, wan, Red, Bilingual Strooo, Wall, White Strobe, Wall, White, Bilingual Strobe, Compact, Wall, Red Strobe, Compact, Wall, Red, srnngual Strobe, Compact, Wall, White Strobe, Compact, Wall, White, Bilingual Strooo, Wall, Red, Plain Strobe, Wall, White, Plain Strobe, Wall, Red, FUEGO Strooo, Wall, White, ALERT SWLED-ALERT Strobe, Wall, White, ALERT. Amber Lens SCRLED SCRLED-B SCRLED-P SCWLED SCWLED-B SCWLED-P SCWLED-CLR- ALEAT L-Serles Horns HRL' HRLA" HWL• HWLA* HGRL0 HGRLA' HGWL" HGWLA" Strobe, Celling, Red Strobe, Ceiling, Red, Bilingual Strobe, Ceiling, White, Plain Strobe, Ceiing, Whit& Strobe, Celine, White, Bilingual Strooo, Ceiing, White, Plain Strobe, Celling, White, ALERT Horn, Red Horn, Red, Plain, ULC Horn, White Hom, White, Plain, ULC Compact Horn, Red Compact Horn, Red, Plain, ULC Compact Horn, White Compact Horn, White, Plain, ULC PWM25-3589FAC Modol Description LEO Lenaee LENS-A3 Lens LED Amber Wall/Celllnfl LENS-83 Lens LED Blue Wall/Ceilina LENS-G3 Lens LED Green WalVCeiling LENS-R3 Lens LED Red Wall/Ceiling Accessories TR-2 , Universal Wall Trim l3ing Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surtace Mount Back Box, Red SBBWL Wall Surtace Mc,unt Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL TRC-2 TRC-2W SBBCRL SBBCWL Bezelst BZR BZW BZGR BZGW BZRC Compact Wall Surface Mount Back Box, White Universal Ceiling Trim Ring, Red Universal Ceiling Trim Ring, White Ceiling Surface Mount Back Box, Red Ceiling Surfac& Mount Back Box, White Wall Red Bezel Kit Wall White Bezel Kit Compact Wall Red Bezel Kn Compact Wall White Bezel Kit Horn Strobe Ceiling Red Bezel Kit Horn Strobe Ceiling Whhe Bezel Kit Notes !or L-Serle& With LEO Hom Strobes and Strobes: All -P models have a P"h housing (no "FIRE" marl<ng en cmer). All -SP models hove 'FUEGo-marl<ng on co,,oer. All -ALERT models have 'ALERr marking on cover. All -B models have 'FIRE,t=EU" marl<lng on cover fo, use n Cenadoin apptlcalions. Amber lenses are not 10, use In canactian applications Notes !or L-Serles Homs: 'Horn-ooly models are listed fo, wall er ceiling use. Notes for Bezels: tEach 00201 pack snips in a package or 5. Add ooe of tt,e folklwl1g extensions for prnt.nanguage opttoos: -F (FIRE), -AL (ALERT), -EV(EVAC), -AG (AGENn, -P (Plan), -FR (FEU), -PG (FOGO), -SP (FUEGO), -$PE (FUEGO/RAE). 3825 Ohio Avenue• SL Charles, IL 60174 USA Phone: 800-SEt-JSOR2 • Fax: 630-377-6495 www.systemsensor.com :t,1lflfl'l~ts&IOl)1$10rr.dt1adeffl•k 01 t-!OnOYW~ 101Mt80)fl&I. Ir,;. Cole Library Fire Alarm Replacement 3333 Unity Drive, Mississauga, ON L5L 3S6 Canada PhOne: 800-SENSOR2 • Fax: 905-812-0771 www.systemsensor.ca Page 33 CZOZ3 ~•t•m Stntor, ProclUCI tp&alk:a:bra lll'.lJICI t> cnl'lQl!IWlrrut n:>ftC6.. 1/1911 ~!k!mwreor,can 10tQlttirl ~a k1'ctmlltbn,l"ll::hd1~ ll'lel~lve-tlona'tl'H dalastlNl A\10591$-01•1~ Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 ® SILENT KNIGHT by Honeywell PWM25-3589FAC SK-Heat, SK-Heat-HT and SK-Heat-ROR Addressable Thennal Heat and Rate-of-Rise Detectors The SK-Heat, SK-Heat-HT, and SK-Heat-ROR are plug in thermal detectors, with integral communication, that provide features that surpass conventional detectors. These thermal detectors are for use with SIient Knight lntelliKnight series Fire Alarm Control Panels (FACPs). lntelliKnight heat detectors are an essential component in virtually any lntelliKnight installation. The lntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Description SK-Heat, SK-Heat-HT and SK- Heat-ROR are intelligent sensors that utilize a state-of-the art thermistor sensing circuit for fast response. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. SK-Heat is a fixed temperature sensor that uses a thermistor sensing circuit to produce 135°F (57°C) fixed temperature alarm. SK-Heat-HT is a variable high temperature detector that provides high temperature detection at 135"F -190°F. (57"C -88"C) SK-Heat-ROR is a rate-of-rise temperature sensor with 135°F (57°C) fixed temperature alarm. Features • Reliable analog communications for trouble-free operation • Age resistant polymer housing • Innovative thermistor sensing circuit • Superior EMI resistance for reliability • Variety of mounting options to meet any application • Dual LED indicators for 360° Cole Library Fire Alarm Replacement visibility • Detector transmits signal to indicate maintenance is required • Plug-in mounting provides ease of installation • Optional remote LED annunciator (System Sensor® PN RA 1 DOZ) • Tamper-proof feature available on mounting bases • Rotary address switches for fast installation • UL Listed Specifications Physical Height: 2.0· (51 mm) Diameter: 6.1" (155 mm)installed in B210LP base Shipping Weight: 4.8 oz (137 g) Electrical Operating Voltage: 15 to 32 Volts DC Peak Standby Current 3001,1A@ 24 VDC LED Current: 6.5 mA@ 24 VDC Environmental Operating Temperature SK-Heat & SK-Heat-ROR: -4° -100°F (-200C-38°C) SK-Heat-HT: -4 ° -150°F (-20°C -66°C) Humidity: 10%-93% noncondensing Thermal Ratings SK-Heat: Fixed temperature alarm 135°F (57°C) Page 34 SK-Heat (base Included) SK-Heat-HT: High temperature heat sensor 135"F -190°F (57'C -88°C) SK-Heat-ROR: Rate-of-rise detection 15°Ffmin (8.3°Cfmin) Compatibility The SK-Heat-HT and SK-Heat- ROR are compatible with the following lntelliKnight FACP's: 5820XL 5805 5700 The SK-Heat is compatible with the following lntelliKnight FACP's: 5820XL 5808 5700 5600 (Rev 2.0 or higher) The SK-Heat, SK-Heat-HT and SK- Heat-ROR are compatible with the following detector bases: B210LP B501 B224B1 B224RB B200SR s• base (included) 2 wire base Isolator base Relay base Sounder base Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 INTELLIKNIC;HT ACCESSORY Model SK-Heat, SK-Heat-HT, SK-Heat ROR Addressable Thermal and Rate-of-Rise Thermal Detectors Engineering Specifications PWM25-3589FAC The contractor shall fumish and install where indicated on the plans, Intelligent Thermal Sensor Silent Knight Model SK-Heat, SK-Heat-HT or SK-Heat-ROR. The base included shall be B210LP. The Heat detector shall have a flashing status LED for visual supervision. When the detector is activated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. • The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required.Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. / / _ _,,,,,,-_..- ;..,...,., ILC IN OUT Campallble FACP RA1DOZ (Opllon•I) r---;• .... ---.., Cl.l1•4-Wlnnu Wiring SK-S..• Delador MOlalllng Bases Accessories M02-09-00 -Test Magnet with Telescoping Handle. RA 1002 -Remote LED Annunciator. RMK400 -Recessed Mounting Klt Provides low profile for use with B501. XR2B -Detector Removal Tool. A removal and re-placement tool for SK plug-in detectors. Includes the T55-127-000. M02--04-01 -Replacement Test Magnet. XP-4 -Extension Pole for XR2B. Extends from 5 -15 fl. T55-127-000 -Detector Removal Head. BCK-200B -Black Detector Kit. For SK-selies detectors. • Unless otherwise noted, specifications apply to all SK thermal detectors. ~ SILENT ~-KNIGHT by Honeywell This document Is not Intended to be used for installation purposes. We try to keep our product Information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact SIient Knight 12 Clintonville Road Northford, CT 06472-1610 Phone: (800) 328-0103, MADE IN AMERICA FORM# 350120 Rev. D © 2011 Honeywel/ lntsmational Inc. Fax: (203) 484-7118. www.sllentknlght.com Cole Library Fire Alarm Replacement Page 35 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 EXHIBIT F Existing System ----- • CARLSBAD COLE LIBRARY FIRE ALARM SYSTEM SITE CARLSBAD COLE LIBRARY 1250 CARLSBAD VILLAGE PRIVE CARLSBAD, CA 92008 11{J[}©@ • ~ff m JP)lltfJJt{{;trff lfj) fllJ(f)/J /J Safer. Smarter. Tyco."' Cole Library Are Alarm Replacement Page36 FMIOf CIJVER81£E1 FA402 t.EIERAI. INFO'WAilOH l'A-111) SllEl'OII' FA-101 rll;VICEPI.AC8IOll'l'VJII FA-i02 DE'w'ICE~PIM ....., .... ,,..... F,1.,60I PNE.OET.ct. FMIXZ 4o»FWELU.'fCllf JoA-701 ll,IRN;ffl'I~ FA-7Dil WlRNG-~ .. - 35611 RUFFlN ROAD SOUTH SAN DIEGO, CA921Zl PHONE: 1158-633-9100 ~~81 PWM25-3589FAC Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 @AL.LAJICN iioffij • J Cole Ubrary Fire Alarm Replacement SYSiEM OF.SCRl?lON / SCO, c 0 .• WG:iK =~-::..ff .. •.:;:;:-...r:cr.s;..,:"D~-=-=-~t..-. oi ........ , ... tt.~·---~ ...... , •. _, __ _ ·-----·--"""_'" .. _""··" .. =--~:l':1':"~-:!.~,~~~ lltlr AIARU A"•PLCAR.F CO<lfS Ii. STA~j/\RDS •---.••-••:1;.wo~ --···-----"·""' ...---.-lll"l ....... ,. ,._.,._...,, _______ _ r.o.w.--•··-- -..:~1 r~""L-... tll:l;:AC1;V2-1 Page37 S''IGBOL Kc¥ e .: ~ \ •• :~ ➔--t=-=-ci, ~=-=-~-~··==-=-· ~1»11aEU ... ~ ; .: = :,-::;-:a ... ~:~~1~,~~; 1.: l · --••-~ ::: ; ~~:: ~·~ 11 ;""'" '-"·-~~ • • PWM25-3589FAC Ji ii ---Ii FA-002 H H Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 I I • ,--------r7 , I i I • 1 Cole Library Fire Alarm Replacement Page38 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM25-3589FAC .... ··--.... ---•-• -,o. ... --.,.-~ .. -1,--:"-·····- -i:;t"'\. 1s, r"cOOR DEY,Cf PlllCCN[t,1 PLAN 'W g i•A .,.. ~ Cole Library Fire Alarm Replacement Page 39 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 Cole Library F. ,re Alarm Re I pacement ~ -W•" DCVCC PlACC • ~ 2ND 11.000 Page40 ..., PWM25-3589FAC f,--·-·;: __ ----,---, I i: Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 ~: ;.:?~:,-'~;=~~: u. ~;: ~ 1:1 ~~~~,2!......./.°!"~-Z;'4t;t'J4 ,·~--~ ._ ga;. r ~ _, • .., "' ffl • lM ...;,~ •I Im -,,---ai1 111-IJC ~1-)1.t ·• -Oil II"~ ~1-• W'-CU lM "4 .W-XI l;n El -•-J!-J -vl-:&C ·-tJ '7-~ ca -~ -~~1.--- ,l'-•• Sl'mJJl'UXl7 ----------------------------------' Fl .. ~ ,t'_.._._~ ,>'-~-.!~ ;•-_ r: ";~__,:'-'.~"-_-<•i;c"-3"'-__ -.1:~~:r_ -~·-~~·~~".'.._-~J j . ,J,•-'.~• ,1·-.,: J•m 1-14-1-ir.,:11<~'-,i_•fL.-' i i i ff<STr..:-~;i, ____________________________________ --~ F Cole Library Fire Alarm Replacement Page41 PWM25-3589FAC ------~L,\ ... • .. I .,! 1q l;3 i I, I t1 J L· i 1inl i j i I I I lhl i m11 I!: !l 1li jr u ii ~H+H+Htill i; !l ii Ii ---__ ----<·1i Iii ---1:i FA-201 u Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 I I "· •. ~j, ... ·~ !L-l~~::fi~-· Lk ~-- i •:,:.:;:, "<.:O~· . -.-=--=-===--'.-.. ---'--=~..i ___ __, cXISTNG 40'0 rACP r,\NH r.EVICC -·-·-·7 ----' "":."\, ·:=··~·-= ___ .,•.am...,~-·= --~;;:;=-1-" PWM25-3589FAC h !i ;, •---ii ;i II. --!I FMi01 ii .,__ ____________________________________________ ..J... __ __J,j Cole Library Fire Alarm Replacement Page42 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 - ----·-=---- ~~ -~-. • ----= . _ -a 11· .111;-;;;;;J Cole Library F ,re Alarm Replacement Page43 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 PWM25-3589FAC -----------· --------- -,,--, Cole Library Fire Alarm Replacement Page44 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 I I . : I I I ! I ' Cole Library Fire Alarm Replacement Page45 I _! CY.7,,,.,,,., .... .... -..,.,.,tv __ ,"' ' ........ ~, -~i:,rc,wrw.-~rt>• ... I!. • .,,.•-a•~-""rf1"•~,; ·=.'it',~-=~~-t ..... ,..,,_~ PWM25-3589FAC 111- SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. INSURER(S) AFFORDING COVERAGE INSURER F : INSURER E : INSURER D : INSURER C : INSURER B : INSURER A : NAIC # NAME:CONTACT (A/C, No):FAX E-MAILADDRESS: PRODUCER (A/C, No, Ext):PHONE INSURED REVISION NUMBER:CERTIFICATE NUMBER:COVERAGES IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. OTHER: (Per accident) (Ea accident) $ $ N / A SUBR WVD ADDL INSD THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THISCERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. $ $ $ $PROPERTY DAMAGE BODILY INJURY (Per accident) BODILY INJURY (Per person) COMBINED SINGLE LIMIT AUTOS ONLY AUTOSAUTOS ONLY NON-OWNED SCHEDULEDOWNED ANY AUTO AUTOMOBILE LIABILITY Y / N WORKERS COMPENSATION AND EMPLOYERS' LIABILITY OFFICER/MEMBER EXCLUDED?(Mandatory in NH) DESCRIPTION OF OPERATIONS belowIf yes, describe under ANY PROPRIETOR/PARTNER/EXECUTIVE $ $ $ E.L. DISEASE - POLICY LIMIT E.L. DISEASE - EA EMPLOYEE E.L. EACH ACCIDENT EROTH-STATUTEPER LIMITS(MM/DD/YYYY)POLICY EXP(MM/DD/YYYY)POLICY EFFPOLICY NUMBERTYPE OF INSURANCELTRINSR DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) EXCESS LIAB UMBRELLA LIAB $EACH OCCURRENCE $AGGREGATE $ OCCUR CLAIMS-MADE DED RETENTION $ $PRODUCTS - COMP/OP AGG $GENERAL AGGREGATE $PERSONAL & ADV INJURY $MED EXP (Any one person) $EACH OCCURRENCE DAMAGE TO RENTED $PREMISES (Ea occurrence) COMMERCIAL GENERAL LIABILITY CLAIMS-MADE OCCUR GEN'L AGGREGATE LIMIT APPLIES PER: POLICY PRO-JECT LOC CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) CANCELLATION AUTHORIZED REPRESENTATIVE ACORD 25 (2016/03) © 1988-2015 ACORD CORPORATION. All rights reserved. CERTIFICATE HOLDER The ACORD name and logo are registered marks of ACORD HIREDAUTOS ONLY 4/25/2024 Patriot Risk & Insurance Services18952 MacArthur Blvd., Suite #300Irvine, CA 92612 949-486-7904 www.patrisk.com 0K07568 Everest Indemnity Insurance Company 10851 Everest Denali Insurance Company 16044 Insurance Company of the West 27847 Ohio Security Insurance Company 24082 A 1,000,00051GL0053912413/4/2024 3/4/2025 50,000 3 5,000 3 1,000,000 2,000,000 2,000,0003 B 51CAD00332241 3/4/2024 3/4/2025 1,000,000 3 3 3 A 51E0004708241 3/4/2024 3/4/2025 4,000,0003 4,000,0003 C WSD507634300 3/4/2024 3/4/2025 3 1,000,000 1,000,000 1,000,000 D Installation Floater BKO57829560 3/4/2024 3/4/2025 Limit: $100,000 / Deductible $1,000 A Errors & Omissions 51GL005391241 3/4/2024 3/4/2025 Limit $1,000,000/Agg $2,000,000 Dave Jacobson Annette Romero aromero@patrisk.com (Included with General Liability)(Included with General Liability) Accent Electronics Inc.dba Standard Electronics613 W. Main Street El Cajon CA 92020 79687611 3 3 City of Carlsbad/CMWD is named as Additional Insured as respects to General Liability Endorsements attached City of Carlsbad/CMWD c/o EXIGIS Insurance Compliance Services P.O. Box 947 Murrieta CA 92564 Re: All Projects Waiver of Subrogation applies to WC and in favor of the City of Carlsbad *30-day notice of cancellation / 10-days for non-payment of premium. 79687611 | 24/25 GL & E&O/Auto/XS/WC/Inst Fltr | Annette Romero | 4/25/2024 8:55:33 AM (PDT) | Page 1 of 5 This certificate cancels and supersedes ALL previously issued certificates. Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 f--D □ f-- f-- Fl □ □ f-- f--~ f--f-- f--f-- f--H I I I I I □ Accent Electronics Inc. 51GL005391241 City of Carlsbad All Projects 79687611 | 24/25 GL & E&O/Auto/XS/WC/Inst Fltr | Annette Romero | 4/25/2024 8:55:33 AM (PDT) | Page 2 of 5This certificate cancels and supersedes ALL previously issued certificates. Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 POLICY NUMBER: COMMERCIAL GENERAL LIABILITY CG 2010-0413 .. THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. ADDITIONAL INSURED -OWNERS, LESSEES OR CONTRACTORS -SCHEDULED PERSON OR ORGANIZATION This endorsement modifies Insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART SCHEDULE Name Of Additional Insured Person(s) Or Organlzation(s): Locatlon(s) Of Covered Operations Information required to complete this Schedule, if not shown above, will be shown In the Declarations. A. Section II • Who Is An Insured is amended to Include as an additional Insured the person(s) or organlzatlon(s) shown in the Schedule, but only with respect to liability for "bodily In- jury .. , "property damage" or "personal and advertising Injury" caused, In whole or In part, by: 1. Youracts or omissions; or 2. The acts or omissions of those acting on your behalf; In the performance of your ongoing operatons for the addltlonal lnsured(s) at the locatlon(s) designated above. However: 1. The Insurance afforded to such additional Insured only applies to the extent permit• ted by law; and 2. If coverage provided to the additional In- sured is required by a contract or agree- ment, the Insurance afforded to such additional Insured will not be broader than that which you are required by the contract or agreement to provide for such additional insured. B. With respect to the insurance afforded to these additional Insureds, the followlng addi- tional exclusions apply: This Insurance does not apply to "bodily In- jury" or" property damage" occurring after: 1. All work, Including materials, parts or equipment furnished in connection with such work, on the project (other than ser- vice, maintenance or repairs) to be per- formed by or on behalf of the additional insured(s) at the location of the covered operations has been completed; or 2. That portion of "your work" out of which the Injury or damage arises has been put to Its Intended use by any· person or or- ganization other than another contractor or subcontractor engaged in performing operations for a principal as a part of the same project. CG2010 0413 ® Insurance Services Office, Inc., 2012 Paga 1 of 2 79687611 | 24/25 GL & E&O/Auto/XS/WC/Inst Fltr | Annette Romero | 4/25/2024 8:55:33 AM (PDT) | Page 3 of 5 This certificate cancels and supersedes ALL previously issued certificates. Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 C. With respect to the Insurance afforded to these additional insureds, the following is added to Section 111-Umits Of Insurance: If coverage provided to the additional insured Is required by a contract or agreement, the most we wlll pay on behalf of the additional insured is the amount of Insurance: 1. Required by the contract or agreement; or 2. Available under the applicable limits of Insurance shown in the Declarations; whichever is less. This endorsement shall not increase the ap- plicable Limits of Insurance shown in the Dec- larations. Page2 of2 © Insurance Services Office, Inc., 2012 CG 20100413 Accent Electronics Inc.dba Standard Electronics 51GL005391241 79687611 | 24/25 GL & E&O/Auto/XS/WC/Inst Fltr | Annette Romero | 4/25/2024 8:55:33 AM (PDT) | Page 4 of 5 This certificate cancels and supersedes ALL previously issued certificates. Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 POLICY NUMBER: COMMERCIAL GENERAL LIABILITY CG 20 37 0413 THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. ADDITIONAL INSURED -OWNERS, LESSEES OR CONTRACTORS -COMPLETED OPERATIONS This endorsement modifies insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART PRODUCTS/COMPLETED OPERATIONS LIABILITY COVERAGE PART SCHEDULE Name Of Additional Insured Person(s) Or Omanizationls\ Location And Description Of Completed Ooeratlons As Required By Written Contract, Fully Executed Prior Any project or premises where work was performed by To The Named lnsured's Work or on behalf of the insured other than a residential tract project which is defined as any project comprised of a piece or parcel of land that is subdivided into five or more lots for the construction of freestanding one, two, three or four family dwellings. Information required to complete this Schedule, if not shown above, will be shown in the Declarations. A. Section II -Who Is An Insured is amended to include as an additional insured the person(s) or organization(s) shown in the Schedule, but only with respect to liability for "bodily injury" or "property damage" caused, in whole or in part, by "your workn at the location designated and described in the Schedule of this endorsement performed for that additional insured and included in the "products-completed operations hazard". However: 1. The insurance afforded to such additional insured only applies to the extent permitted bylaw; and 2. If coverage provided to the additional insured is required by a contract or agreement, the insurance afforded to such additional insured will not be broader than that which you are required by the contract or agreement to provide for such additional insured. B. With respect to the insurance afforded to these additional insureds, the following is added to Section Ill -Limits Of Insurance: If coverage provided to the additional insured is required by a contract or agreement, the most we will pay on behalf of the additional insured is the amount of insurance: 1. Required by the contract or agreement; or 2. Available under the applicable Limits of Insurance shown in the Declarations; whichever is less. This endorsement shall not increase the applicable Limits of Insurance shown in the Declarations. CG 20 370413 © Insurance Services Office, Inc., 2012 Page 1 of 1 Accent Electronics Inc. dba Standard Electronics City of Carlsbad/CMWD 4/25/2024 3/4/2024 WSD507634300 79687611 | 24/25 GL & E&O/Auto/XS/WC/Inst Fltr | Annette Romero | 4/25/2024 8:55:33 AM (PDT) | Page 5 of 5 This certificate cancels and supersedes ALL previously issued certificates. Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2 1.. ' CALJFORN IA ' 1 DEPARTMENT OF INSURANCE I I I Docusign Envelope ID: 35574F7A-739A-48B4-91D2-B50E4B92DFC2