HomeMy WebLinkAboutCD 13-08; Alga Norte Community Park; Administrative Permits (ADMIN)_.if~.A_ CITY OF
VcARLSBAD
Community & Economic Development
August 9, 2013
Patrick McGarry
City of Carlsbad-PEM
405 Oak Street
Carlsbad, CA 92008
SUBJECT: CD 13-08-ALGA NORTE COMMUNITY PARK (SOLAR PV PANELS)
www.carlsbadca.gov
The City Planner has completed a review of your application for the installation of shade structures with
solar PV panels, (APN: 213-110-04) which is a modification to the parking lot of the Alga Norte
Community Park (CUP 04-08). The proposed modifications include:
• Six cantilevered photovoltaic shade system structures will be constructed within the parking
lot located to the east of the swim complex.
• The shade structures will be approximately 206' x 39' with a minimum 8' clearance height.
• The center support columns will be placed within the center of the planting areas so as not
to interfere with vehicle parking spaces.
• The plans indicate that a minimum clear path of 34' will be provided in the area of the drive
aisle between the shade structures. This distance complies with the Fire Department
requirements to maintain a minimum of 20' of clearance between structures with a clear
vertical distance of no less than 13'-6".
• The plant species under the shade structure will be revised to the satisfaction of the Parks
and Recreation Department.
In order for a Discretionary Permit Consistency Determination to be approved, all of the following
findings must be made:
1} No project condition, feature, facility or amenity is changed or deleted that had been considered
essential to the project's design, quality, safety or function.
2} The request represents an upgrade in overall design features and or materials and improves
upon the project's compatibility with the surrounding neighborhood.
3) The proposed revision does not change the density or boundary of the subject property.
4} The proposed revision does not involve the addition of a new land use not shown on the original
permit.
5} The proposed revision does not rearrange the major land uses within the development.
6} The proposed revision does not create changes of greater than ten percent provided that
compliance will be maintained with the applicable development standards of the Carlsbad
Municipal Code.
7} The proposed change will not result in any significant environmental impact, and/or require
additional mitigation.
8} The proposed change would not result in any health, safety or welfare impacts.
Planning Division
1635 Faraday Avenue, Carlsbad, CA 92008-7314 T 760-602-4600 F 760-602-8559
l
CD 13-08-ALGA NORTE COMMUNITY PARK (SOLAR PV PANELS)
'\(ogU); 9; 1DB .. .
Pagel ·
9} There were not any major issues or controversies associated with the original project which
would be exacerbated with the proposed change.
10) The proposed change would not be readily discernable to the decision makers as being
substantially different from the project as originally approved.
After careful consideration of the circumstances surrounding this request, the City Planner has
determined that the application qualifies for a consistency determination with the approved permit and
therefore, approves the changes to the project based on Planning Division Administrative Policy No. 35.
Please submit two (2) blueline copies {24" X 36") of all applicable exhibits for the project file and a
reproducible 24" X 36" mylar copy of the amended site plan. The mylar must be submitted, stamped
"Consistency Determination," and signed by the City Planner prior to issuance of any building permits
for the project. The Consistency Determination Title Block stamp, and other Title Block stamps, can be
downloaded from the City's website at
http://www.carlsbadca.gov/services/departments/planning/Pages/applications.aspx. The Title Block
(stamp) is located under "Resources" on the right side of the page.
CITY OF CARLSBAD
DON NEU, AICP
City Planner
DN:BK:fn
c: Patrick McGarry, Civic Projects Manager
Principal Planner, Dave de Cordova
Project Engineer, Jason Geldert
Fire Prevention, Greg Ryan
File Copy
Data Entry
CITY OF CARLSBAD
REVIEW AND COMMENT MEMO
t=ll F COPY
DATE: JULY 24, 2013
CD 13-08 (CUP 04-08} REVIEW NO: --------~------~-----------------------PROJECT NO(S}: 1
PROJECT TITLE: ALGA NORTE COMMUNITY PARK (SOLAR PV PANELS}
APPLICANT: CITY OF CARLSBAD/PATRICK McGARRY
TO:
[8j Land Development Engineering
D Police Department-J. Sa sway
[8j Fire Department-Greg Ryan
D Building Division-Will Foss
D Parks & Recreation {Parks/Trails)-Liz Ketabian
D Parks & Recreation {Trees & Medians)-Mike Bliss
D Public Works Department {Streets)-Nick Roque
D Public Works Department {Traffic)-John Kim
D Public Works Department {Design)-Bill Plummer
*ALWAYS SEND EXHIBITS
FROM: PLANNING DIVISION
D Public Works {Storm Drain)-Clayton Dobbs
D Public Works {Wastewater)-Don Wasko
D Public Works {Water)-Jase Warner
D Water/Sewer District
D Landscape Plancheck Consultant -PELA
D School District
D North County Transit District-Planning Dept.
D Sempra Energy-Land Management
D Caltrans {Send anything adjacent to 1-5)
Please review and submit written comments and/or conditions to the PLANNING TRACKING DESK in the
Planning Division at 1635 Faraday Avenue, by 8/14/13. If you have "No Comments," please so state. If you
determine that there are items that need to be submitted to deem the application "complete" for
processing. please immediately contact the applicant and/or their representatives (via phone or e-mail) to
let them know.
Thank you
COMMENTS: ______________________________ _
Signature Date
PLANS ATIACHED
Review & Comment 03/13 BK
CITY OF CARLSBAD
REVIEW AND COMMENT MEMO
DATE: JULY 24, 2013
CD 13-08 (CUP 04-08) REVIEW NO: ------~~----~------------------------PROJECT NO(S): 1
PROJECT TITLE: ALGA NORTE COMMUNITY PARK (SOLAR PV PANELS)
APPLICANT: CITY OF CARLSBAD/PATRICK McGARRY
TO:
IZ! Land Development Engineering
0 Police Department-J. Sa sway
IZ! Fire Department-Greg Ryan
0 Building Division-Will Foss
0 Parks & Recreation (Parks/Trails)-Liz Ketabian
0 Parks & Recreation (Trees & Medians)-Mike Bliss
0 Public Works Department (Streets)-Nick Roque
0 Public Works Department (Traffic)-John Kim
0 Public Works Department (Design)-Bill Plummer
*ALWAYS SEND EXHIBITS
FROM: PLANNING DIVISION
0 Public Works (Storm Drain)-Clayton Dobbs
0 Public Works (Wastewater) -Don Wasko
0 Public Works (Water)-Jase Warner
0 Water/Sewer District
0 landscape Plancheck Consultant-PELA
D School District
0 North County Transit District-Planning Dept.
0 Sempra Energy -land Management
0 Caltrans (Send anything adjacent to 1-5)
Please review and submit written comments and/or conditions to the PLANNING TRACKING DESK in the
Planning Division at 1635 Faraday Avenue, by 8/14/13. If you have "No Comments," please so state. If you
determine that there are items that need to be submitted to deem the application "complete" for
processing, please immediately contact the applicant and/or their representatives (via phone or e-mail) to
let them know.
Thank you A 1 t
COMMENTS: ____ _./V~x.(D_-Io:G,.....C..LJ<4-cl.:....Ji..f-Jm&~t1~·~-f ____________ _
1 Dale
PLANS ATTACHED
Review & Comment 03/13 BK
-·-CITY OF CARLSBAD
REVIEW AND COMMENT MEMO
DATE: JULY 24, 2013
PROJECT NO(S}: CD 13-08 (CUP 04-08} REVIEW NO: ~--~~~~--~~-----------------------1
PROJECT TITLE: ALGA NORTE COMMUNITY PARK (SOLAR PV PANELS)
APPLICANT: CITY OF CARLSBAD/PATRICK McGARRY
TO:
IZ! Land Development Engineering
D Police Department-J. Sasway
IZ! Fire Department-Greg Ryan
D Building Division-Will Foss
D Parks & Recreation (Parks/Trails)-Liz Ketabian
D Parks & Recreation (Trees & Medians)-Mike Bliss
D Public Works Department (Streets)-Nick Roque
D Public Works Department (Traffic)-John Kim
D Public Works Department (Design)-Bill Plummer
*ALWAYS SEND EXHIBITS
FROM: PLANNING DIVISION
D Public Works (Storm Drain)-Clayton Dobbs
D Public Works (Wastewater)-Don Wasko
D Public Works (Water)-Jase Warner
D Water/Sewer District
D Landscape Plancheck Consultant-PELA
D School District
D North County Transit District-Planning Dept.
D Sempra Energy-Land Management
D Caltrans (Send anything adjacent to 1-5)
Please review and submit written comments and/or conditions to the PLANNING TRACKING DESK in the
Planning Division at 1635 Faraday Avenue, by 8/14/13. If you have "No Comments," please so state. If you
determine that there are items that need to be submitted to deem the application "complete" for
processing, please immediately contact the applicant and/or their representatives (via phone or e-mail) to
let them know.
Thank you
coMMENTs: Se.c.. A"'T11\GH:JIAEJ..lr
Date
PLANS ATIACHED
Review & Comment 03/13 BK
... ~ ....
CARLSBAD FIRE DEPARTMENT
FIRE PREVENTION BUREAU
Discretionary Review Checklist
PROJECT NUMBER: CD 13-08 ALGA NORTE COMM. PARK
BUILDING ADDRESS: 6565 ALICANTE RD ~~~~~---------------------------------------------------------------------------------------------
PROJECT DESCRIPTION: PHOTOVOLTAIC INSTALLATION
ASSESSOR'S PARCEL NUMBER:
FIRE DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans, information
and/or specifications provided in your submittal;
therefore, any changes to these items after this date,
including field modifications, must be reviewed by this
office to insure continued conformance with applicable
codes. Please review carefully all comments attached,
as failure to comply with instructions in this report can
result in suspension of permit to build.
By: t;.:?.gan Date: 07.31.2013 -------------------------i
ATTACHMENTS
DENIAL
Please see the attached report of deficiencies marked with
lXI. Make necessary corrections to plans or specifications
for compliance with applicable codes anc;l standards.
Submit corrected plans and/or specifications to this office
for review.
By: Date:
By: Date: ----------
By: Date: -------
FIRE DEPARTMENT CONTACT PERSON
NAME: GREGORY L RYAN
ADDRESS: 1635 Faraday Ave
Carlsbad, CA 92008
PHONE: (760) 602-4665
COMMENTS: FIRE IS O.K. WITH THE PROPOSAL TO INSTALL CANTILEVERED SOLAR PANELS
SHADE STRUCTURE IN THE PARKING AREA OF THIS PUBLIC FACILITY. HOWEVER, YOU SHALL
MAINTAiN NO LESS.JHAN 20,FEET OF CLEARANCE BETWEEN STRUCTURES WITH A CLEAR VERTICAL
HEIGHT OF NO LESS THAN 13-FEET-6-INCHES.
,_--"""'! CITY OF CARLSBAD APPLICATION FORM FOR CONSISTENCY DETERMINATION APPLICATION
CITY USE ONLY
Project Number:
PROJECT NAME: Alga Norte Community Park-Salay PV
Assessor's Parcel Number(s): 2131100400
C./J !3-o ~
------------------------------------------------------------
Description of proposal (add attachment if necessary): installation of structure mounted solar photo-voltaic panels
in the parking lot of Alga Norte Community Park
Would you like to orally present your proposal to your assigned staff planner/engineer? Yes ~No
Please list the staff members you have previously spoken to regarding this project. If none, please so state.
Barbara Kennedy
OWNER NAME (Print): City of Carlsbad
--~----------------------MAILING ADDRESS: 405 Oak St
APPLICANT NAME (Print): ~ 4Q ~~.-er
MAILING ADDRESS:
0
~~~~~~~----------------------------------------CITY, STATE, ZIP: Carlsbad, CA 92010 ----------------------------TELEPHONE: 760-434-2949 ----------------------------EMAIL ADDRESS: patrick. mcgarry@carlsbadca.gov
*Owner's signature indicates permission to conduct a preliminary
review for a development proposal.
I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE
ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF
MY KNOWLEDGE.
SIGNATURE DATE
APPLICANT'S REPRESENTATIVE (Print): Patrick McGarry
CITY, STATE, ZIP:
TELEPHONE:
EMAIL ADDRESS:
I CERTIFY THAT I AM THE LEGAL REPRESENTATIVE OF THE
OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE
AND CORRECT TO THE BEST OF MY KNOWLEDGE.
SIGNATURE DATE
--------------------------------------------------------MAILING ADDRESS: same as owner
CITY, STATE, ZIP:
TELEPHONE:
EMAIL ADDRESS:
I CERTIFY THAT I AM THE LEGAL REPRESENTATIVE OF THE
APPLICANT AND THAT ALL THE ABOVE INFORMATION IS TRUE AND
CORR J ~E$T OF MY KNOWLEDGE.
-~~~1:---:E~~~.:..___--=-+--· a;;. ""4d3
SIG DATE
G THIS APPLICATION IT MAY BE NECESSARY FOR MEMBERS OF CITY STAFF TO INSPECT AND
THE SUBJECT OF THIS APPLICATION. 1/WE CONSENT TO ENTRY FOR THIS PURPOSE.
FEE REQUIRED/DATE FEE PAID:
RECEIVED BY:
P-16 Page 2 of2 Revised 07/10
/ • . i
MATCHLINE SEE SHEET E201
8 ~~~~~CAL SITE PLAN NORTH
.3HA-17
.3(4"C.If6,f6N,f10C
r--EX!S11NG SDC&E PRIMARY
!J; PULL BOX
I
~ Approximate size of canopy =>:.1t<>.:c-:----l1r;s 136' x 48'
\
10 (2)3" SPARE CONDUITS FOR FUTURE PV .
-~\ __________ _
'
~ ~CARLSBAD
Alga Norte Community
Park
Solar Photo-voltaic RFP
Exhibit "A"
Design Intent Documents
sl> 15
•
ALGA NORTE COMMUNITY PARK · PV PROJECT
~ ]
c.:
~--~ II•
I 1', II II I' ,,
ol Ill m II II 'I
PROPOSED INVERTER LOCATION TYP.
PROPOSED POINT OF INTERCONNECTION
'SAl
CentE3r columns of dual
.. cantilever shade
s~ructures shall !J e placed
i th~·HAQf3nter plater area
(typ4.E{f1'6arrays)
--~--
rr--EXISTING SDG&E PRIMARY
~ PULL BOX
I
~
NEW SDG&E
SWITCHBOARD CABINET
PROJECT INFORMATION
L.-• '1::'
~~ P"'
I' I
./
> ' i
... -~ .. "·""'') ._,\ '= -.-
PROPOSAL SPECIFICATIONS
SYSTEM SIZE DC (kW) 626.400
SYSTEM SIZE AC-CEC (kW) 539.593
DC TO AC RATIO 1.25
MODULE INFORMATION (2,088) YINGLI YL300P-35b
STRING INFORMATION (174) PARALLELED STRINGS OF ( 12)
INVERTER INFORMATION (1) AE 500NX-HE 480
TRANSFORMER INFORMATION NONE
INTERCONNECTION VOLTAGE 480V
RACKING DETAILS SOLAR SUPPORT STRUCTURES
GROUND SLOPE (•) 0 SITE LATITUDE
TOTAL PARCEL AREA (SQ.FT) 42804 GROUND SNOW LOAD (PSF)
BASIC WIND SPEED (MPH) TBD NUMBER OF FOUNDATIONS
MATERIAL TO TRENCH ASPHALT AC TRENCH LENGTH f)
DETAILED INFORMATION
TILT DUMMY NO. OF NO. OF
ARRAY NO. AZIMUTH ANGLE MODULES MODULES STRINGS
ARRAY
SQ. FT
SS-1 180" 10" 0 2,088 174 42,804.00
TOTAL 0 2,088 174 42,804.00
33.11 N
TBD
TBD
115
KWDC
626.400
626.400
PV MODULES, TYP.
BEAM
PURLIN, TYP.
PROPOSAL NOTES
1. SCOPE OF THIS DRAWING: A PRE-CONTRACT ESTIMATE OF POTENTIAL SOLAR
ARRAY SIZE AND LOCATION
2. ALL DIMENSIONS SPECIFIED HERE ARE FOR REFERENCE ONLY; DO NOT SCALE
THIS DRAWING. CONFIRM KEY DIMENSION IN THE FIELD BEFORE BEGINNING
INSTALLATION. PROPER DIMENSION FOR THIS ROOFTOP AND BUILDING
SHOULD BE OBTAINED FROM THE CUSTOMER
3. THIS PHOTOVOLTAIC INSTALLATION SHALL BE INSTALLED IN ACCORDANCE
WITH THE EDITIONS OF THE UNIFORM BUILDING CODE (UBC), THE NATIONAL
ELECTRICAL CODE (NEC), AND ANY LOCAL BUILDING CODES CURRENTLY
BEING ENFORCED BY THE AUTHORITY HAVING JURISDICTION (AHJ).
V3
THIS DOCUMENT IS PROVIDED BY BORREGO SOLAR
SYSTEMSNC. TO FACILITATE THE SALEANO
INSTAlLATION OF A SOlAR POWER SYSTEM FROM
BORREGO SOLAR SYSTEMS. REPRODUCTION,
RELEASE OR UTILIZATION FOR IWf OTHER
PlRPOSE, WITHOUT PRIOR ~mEN CONse/T IS
STRICTLY PROHIBITED.
-' w > w -' w en L5 -' w 0::
0 w "" u w I u
z s: ~ 0
w ~ 0
BORREGO SOLAR
5005 TEXAS STREET, SUITE 400
SAN DIEGO, CA 92108
PHONE: (888) 898-6273
FAX: (888) 843-6778
WNW.BORREGOSOLAR.COM
0> 0 0 N ~ 0>
0:::<( <Co
Q_ ->-0 t-<C -co z(/)
:::::>_J
~0::: ~<( o<->
<..>6 wo::: 1-0:::~ Oz z<C <(<..> <..9-_J_J
<(<(
lO <D lO <D
PROJECT NUMBER:
P-SD-004050
z 1-0 => u; 0 5 5 w 0::
-' -' <( ;% en 0 0 "-"-0 ~ 0:: "-"-
X X 0 0
:::;; :::;; <( <( en en
"' "' ~ iii ~ Q "' 0 0
SCALE: 1"=80'
VALID ONLY WHEN PLOffiD
ANSI B 11" X 17"
PV-1
L 1 PROPOSAL lAYOUT