Loading...
HomeMy WebLinkAboutCD 13-08; Alga Norte Community Park; Administrative Permits (ADMIN)_.if~.A_ CITY OF VcARLSBAD Community & Economic Development August 9, 2013 Patrick McGarry City of Carlsbad-PEM 405 Oak Street Carlsbad, CA 92008 SUBJECT: CD 13-08-ALGA NORTE COMMUNITY PARK (SOLAR PV PANELS) www.carlsbadca.gov The City Planner has completed a review of your application for the installation of shade structures with solar PV panels, (APN: 213-110-04) which is a modification to the parking lot of the Alga Norte Community Park (CUP 04-08). The proposed modifications include: • Six cantilevered photovoltaic shade system structures will be constructed within the parking lot located to the east of the swim complex. • The shade structures will be approximately 206' x 39' with a minimum 8' clearance height. • The center support columns will be placed within the center of the planting areas so as not to interfere with vehicle parking spaces. • The plans indicate that a minimum clear path of 34' will be provided in the area of the drive aisle between the shade structures. This distance complies with the Fire Department requirements to maintain a minimum of 20' of clearance between structures with a clear vertical distance of no less than 13'-6". • The plant species under the shade structure will be revised to the satisfaction of the Parks and Recreation Department. In order for a Discretionary Permit Consistency Determination to be approved, all of the following findings must be made: 1} No project condition, feature, facility or amenity is changed or deleted that had been considered essential to the project's design, quality, safety or function. 2} The request represents an upgrade in overall design features and or materials and improves upon the project's compatibility with the surrounding neighborhood. 3) The proposed revision does not change the density or boundary of the subject property. 4} The proposed revision does not involve the addition of a new land use not shown on the original permit. 5} The proposed revision does not rearrange the major land uses within the development. 6} The proposed revision does not create changes of greater than ten percent provided that compliance will be maintained with the applicable development standards of the Carlsbad Municipal Code. 7} The proposed change will not result in any significant environmental impact, and/or require additional mitigation. 8} The proposed change would not result in any health, safety or welfare impacts. Planning Division 1635 Faraday Avenue, Carlsbad, CA 92008-7314 T 760-602-4600 F 760-602-8559 l CD 13-08-ALGA NORTE COMMUNITY PARK (SOLAR PV PANELS) '\(ogU); 9; 1DB .. . Pagel · 9} There were not any major issues or controversies associated with the original project which would be exacerbated with the proposed change. 10) The proposed change would not be readily discernable to the decision makers as being substantially different from the project as originally approved. After careful consideration of the circumstances surrounding this request, the City Planner has determined that the application qualifies for a consistency determination with the approved permit and therefore, approves the changes to the project based on Planning Division Administrative Policy No. 35. Please submit two (2) blueline copies {24" X 36") of all applicable exhibits for the project file and a reproducible 24" X 36" mylar copy of the amended site plan. The mylar must be submitted, stamped "Consistency Determination," and signed by the City Planner prior to issuance of any building permits for the project. The Consistency Determination Title Block stamp, and other Title Block stamps, can be downloaded from the City's website at http://www.carlsbadca.gov/services/departments/planning/Pages/applications.aspx. The Title Block (stamp) is located under "Resources" on the right side of the page. CITY OF CARLSBAD DON NEU, AICP City Planner DN:BK:fn c: Patrick McGarry, Civic Projects Manager Principal Planner, Dave de Cordova Project Engineer, Jason Geldert Fire Prevention, Greg Ryan File Copy Data Entry CITY OF CARLSBAD REVIEW AND COMMENT MEMO t=ll F COPY DATE: JULY 24, 2013 CD 13-08 (CUP 04-08} REVIEW NO: --------~------~-----------------------PROJECT NO(S}: 1 PROJECT TITLE: ALGA NORTE COMMUNITY PARK (SOLAR PV PANELS} APPLICANT: CITY OF CARLSBAD/PATRICK McGARRY TO: [8j Land Development Engineering D Police Department-J. Sa sway [8j Fire Department-Greg Ryan D Building Division-Will Foss D Parks & Recreation {Parks/Trails)-Liz Ketabian D Parks & Recreation {Trees & Medians)-Mike Bliss D Public Works Department {Streets)-Nick Roque D Public Works Department {Traffic)-John Kim D Public Works Department {Design)-Bill Plummer *ALWAYS SEND EXHIBITS FROM: PLANNING DIVISION D Public Works {Storm Drain)-Clayton Dobbs D Public Works {Wastewater)-Don Wasko D Public Works {Water)-Jase Warner D Water/Sewer District D Landscape Plancheck Consultant -PELA D School District D North County Transit District-Planning Dept. D Sempra Energy-Land Management D Caltrans {Send anything adjacent to 1-5) Please review and submit written comments and/or conditions to the PLANNING TRACKING DESK in the Planning Division at 1635 Faraday Avenue, by 8/14/13. If you have "No Comments," please so state. If you determine that there are items that need to be submitted to deem the application "complete" for processing. please immediately contact the applicant and/or their representatives (via phone or e-mail) to let them know. Thank you COMMENTS: ______________________________ _ Signature Date PLANS ATIACHED Review & Comment 03/13 BK CITY OF CARLSBAD REVIEW AND COMMENT MEMO DATE: JULY 24, 2013 CD 13-08 (CUP 04-08) REVIEW NO: ------~~----~------------------------PROJECT NO(S): 1 PROJECT TITLE: ALGA NORTE COMMUNITY PARK (SOLAR PV PANELS) APPLICANT: CITY OF CARLSBAD/PATRICK McGARRY TO: IZ! Land Development Engineering 0 Police Department-J. Sa sway IZ! Fire Department-Greg Ryan 0 Building Division-Will Foss 0 Parks & Recreation (Parks/Trails)-Liz Ketabian 0 Parks & Recreation (Trees & Medians)-Mike Bliss 0 Public Works Department (Streets)-Nick Roque 0 Public Works Department (Traffic)-John Kim 0 Public Works Department (Design)-Bill Plummer *ALWAYS SEND EXHIBITS FROM: PLANNING DIVISION 0 Public Works (Storm Drain)-Clayton Dobbs 0 Public Works (Wastewater) -Don Wasko 0 Public Works (Water)-Jase Warner 0 Water/Sewer District 0 landscape Plancheck Consultant-PELA D School District 0 North County Transit District-Planning Dept. 0 Sempra Energy -land Management 0 Caltrans (Send anything adjacent to 1-5) Please review and submit written comments and/or conditions to the PLANNING TRACKING DESK in the Planning Division at 1635 Faraday Avenue, by 8/14/13. If you have "No Comments," please so state. If you determine that there are items that need to be submitted to deem the application "complete" for processing, please immediately contact the applicant and/or their representatives (via phone or e-mail) to let them know. Thank you A 1 t COMMENTS: ____ _./V~x.(D_-Io:G,.....C..LJ<4-cl.:....Ji..f-Jm&~t1~·~-f ____________ _ 1 Dale PLANS ATTACHED Review & Comment 03/13 BK -·-CITY OF CARLSBAD REVIEW AND COMMENT MEMO DATE: JULY 24, 2013 PROJECT NO(S}: CD 13-08 (CUP 04-08} REVIEW NO: ~--~~~~--~~-----------------------1 PROJECT TITLE: ALGA NORTE COMMUNITY PARK (SOLAR PV PANELS) APPLICANT: CITY OF CARLSBAD/PATRICK McGARRY TO: IZ! Land Development Engineering D Police Department-J. Sasway IZ! Fire Department-Greg Ryan D Building Division-Will Foss D Parks & Recreation (Parks/Trails)-Liz Ketabian D Parks & Recreation (Trees & Medians)-Mike Bliss D Public Works Department (Streets)-Nick Roque D Public Works Department (Traffic)-John Kim D Public Works Department (Design)-Bill Plummer *ALWAYS SEND EXHIBITS FROM: PLANNING DIVISION D Public Works (Storm Drain)-Clayton Dobbs D Public Works (Wastewater)-Don Wasko D Public Works (Water)-Jase Warner D Water/Sewer District D Landscape Plancheck Consultant-PELA D School District D North County Transit District-Planning Dept. D Sempra Energy-Land Management D Caltrans (Send anything adjacent to 1-5) Please review and submit written comments and/or conditions to the PLANNING TRACKING DESK in the Planning Division at 1635 Faraday Avenue, by 8/14/13. If you have "No Comments," please so state. If you determine that there are items that need to be submitted to deem the application "complete" for processing, please immediately contact the applicant and/or their representatives (via phone or e-mail) to let them know. Thank you coMMENTs: Se.c.. A"'T11\GH:JIAEJ..lr Date PLANS ATIACHED Review & Comment 03/13 BK ... ~ .... CARLSBAD FIRE DEPARTMENT FIRE PREVENTION BUREAU Discretionary Review Checklist PROJECT NUMBER: CD 13-08 ALGA NORTE COMM. PARK BUILDING ADDRESS: 6565 ALICANTE RD ~~~~~--------------------------------------------------------------------------------------------- PROJECT DESCRIPTION: PHOTOVOLTAIC INSTALLATION ASSESSOR'S PARCEL NUMBER: FIRE DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore, any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. By: t;.:?.gan Date: 07.31.2013 -------------------------i ATTACHMENTS DENIAL Please see the attached report of deficiencies marked with lXI. Make necessary corrections to plans or specifications for compliance with applicable codes anc;l standards. Submit corrected plans and/or specifications to this office for review. By: Date: By: Date: ---------- By: Date: ------- FIRE DEPARTMENT CONTACT PERSON NAME: GREGORY L RYAN ADDRESS: 1635 Faraday Ave Carlsbad, CA 92008 PHONE: (760) 602-4665 COMMENTS: FIRE IS O.K. WITH THE PROPOSAL TO INSTALL CANTILEVERED SOLAR PANELS SHADE STRUCTURE IN THE PARKING AREA OF THIS PUBLIC FACILITY. HOWEVER, YOU SHALL MAINTAiN NO LESS.JHAN 20,FEET OF CLEARANCE BETWEEN STRUCTURES WITH A CLEAR VERTICAL HEIGHT OF NO LESS THAN 13-FEET-6-INCHES. ,_--"""'! CITY OF CARLSBAD APPLICATION FORM FOR CONSISTENCY DETERMINATION APPLICATION CITY USE ONLY Project Number: PROJECT NAME: Alga Norte Community Park-Salay PV Assessor's Parcel Number(s): 2131100400 C./J !3-o ~ ------------------------------------------------------------ Description of proposal (add attachment if necessary): installation of structure mounted solar photo-voltaic panels in the parking lot of Alga Norte Community Park Would you like to orally present your proposal to your assigned staff planner/engineer? Yes ~No Please list the staff members you have previously spoken to regarding this project. If none, please so state. Barbara Kennedy OWNER NAME (Print): City of Carlsbad --~----------------------MAILING ADDRESS: 405 Oak St APPLICANT NAME (Print): ~ 4Q ~~.-er MAILING ADDRESS: 0 ~~~~~~~----------------------------------------CITY, STATE, ZIP: Carlsbad, CA 92010 ----------------------------TELEPHONE: 760-434-2949 ----------------------------EMAIL ADDRESS: patrick. mcgarry@carlsbadca.gov *Owner's signature indicates permission to conduct a preliminary review for a development proposal. I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE APPLICANT'S REPRESENTATIVE (Print): Patrick McGarry CITY, STATE, ZIP: TELEPHONE: EMAIL ADDRESS: I CERTIFY THAT I AM THE LEGAL REPRESENTATIVE OF THE OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE --------------------------------------------------------MAILING ADDRESS: same as owner CITY, STATE, ZIP: TELEPHONE: EMAIL ADDRESS: I CERTIFY THAT I AM THE LEGAL REPRESENTATIVE OF THE APPLICANT AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORR J ~E$T OF MY KNOWLEDGE. -~~~1:---:E~~~.:..___--=-+--· a;;. ""4d3 SIG DATE G THIS APPLICATION IT MAY BE NECESSARY FOR MEMBERS OF CITY STAFF TO INSPECT AND THE SUBJECT OF THIS APPLICATION. 1/WE CONSENT TO ENTRY FOR THIS PURPOSE. FEE REQUIRED/DATE FEE PAID: RECEIVED BY: P-16 Page 2 of2 Revised 07/10 / • . i MATCHLINE SEE SHEET E201 8 ~~~~~CAL SITE PLAN NORTH .3HA-17 .3(4"C.If6,f6N,f10C r--EX!S11NG SDC&E PRIMARY !J; PULL BOX I ~ Approximate size of canopy =>:.1t<>.:c-:----l1r;s 136' x 48' \ 10 (2)3" SPARE CONDUITS FOR FUTURE PV . -~\ __________ _ ' ~ ~CARLSBAD Alga Norte Community Park Solar Photo-voltaic RFP Exhibit "A" Design Intent Documents sl> 15 • ALGA NORTE COMMUNITY PARK · PV PROJECT ~ ] c.: ~--~ II• I 1', II II I' ,, ol Ill m II II 'I PROPOSED INVERTER LOCATION TYP. PROPOSED POINT OF INTERCONNECTION 'SAl CentE3r columns of dual .. cantilever shade s~ructures shall !J e placed i th~·HAQf3nter plater area (typ4.E{f1'6arrays) --~-- rr--EXISTING SDG&E PRIMARY ~ PULL BOX I ~ NEW SDG&E SWITCHBOARD CABINET PROJECT INFORMATION L.-• '1::' ~~ P"' I' I ./ > ' i ... -~ .. "·""'') ._,\ '= -.- PROPOSAL SPECIFICATIONS SYSTEM SIZE DC (kW) 626.400 SYSTEM SIZE AC-CEC (kW) 539.593 DC TO AC RATIO 1.25 MODULE INFORMATION (2,088) YINGLI YL300P-35b STRING INFORMATION (174) PARALLELED STRINGS OF ( 12) INVERTER INFORMATION (1) AE 500NX-HE 480 TRANSFORMER INFORMATION NONE INTERCONNECTION VOLTAGE 480V RACKING DETAILS SOLAR SUPPORT STRUCTURES GROUND SLOPE (•) 0 SITE LATITUDE TOTAL PARCEL AREA (SQ.FT) 42804 GROUND SNOW LOAD (PSF) BASIC WIND SPEED (MPH) TBD NUMBER OF FOUNDATIONS MATERIAL TO TRENCH ASPHALT AC TRENCH LENGTH f) DETAILED INFORMATION TILT DUMMY NO. OF NO. OF ARRAY NO. AZIMUTH ANGLE MODULES MODULES STRINGS ARRAY SQ. FT SS-1 180" 10" 0 2,088 174 42,804.00 TOTAL 0 2,088 174 42,804.00 33.11 N TBD TBD 115 KWDC 626.400 626.400 PV MODULES, TYP. BEAM PURLIN, TYP. PROPOSAL NOTES 1. SCOPE OF THIS DRAWING: A PRE-CONTRACT ESTIMATE OF POTENTIAL SOLAR ARRAY SIZE AND LOCATION 2. ALL DIMENSIONS SPECIFIED HERE ARE FOR REFERENCE ONLY; DO NOT SCALE THIS DRAWING. CONFIRM KEY DIMENSION IN THE FIELD BEFORE BEGINNING INSTALLATION. PROPER DIMENSION FOR THIS ROOFTOP AND BUILDING SHOULD BE OBTAINED FROM THE CUSTOMER 3. THIS PHOTOVOLTAIC INSTALLATION SHALL BE INSTALLED IN ACCORDANCE WITH THE EDITIONS OF THE UNIFORM BUILDING CODE (UBC), THE NATIONAL ELECTRICAL CODE (NEC), AND ANY LOCAL BUILDING CODES CURRENTLY BEING ENFORCED BY THE AUTHORITY HAVING JURISDICTION (AHJ). V3 THIS DOCUMENT IS PROVIDED BY BORREGO SOLAR SYSTEMSNC. TO FACILITATE THE SALEANO INSTAlLATION OF A SOlAR POWER SYSTEM FROM BORREGO SOLAR SYSTEMS. REPRODUCTION, RELEASE OR UTILIZATION FOR IWf OTHER PlRPOSE, WITHOUT PRIOR ~mEN CONse/T IS STRICTLY PROHIBITED. -' w > w -' w en L5 -' w 0:: 0 w "" u w I u z s: ~ 0 w ~ 0 BORREGO SOLAR 5005 TEXAS STREET, SUITE 400 SAN DIEGO, CA 92108 PHONE: (888) 898-6273 FAX: (888) 843-6778 WNW.BORREGOSOLAR.COM 0> 0 0 N ~ 0> 0:::<( <Co Q_ ->-0 t-<C -co z(/) :::::>_J ~0::: ~<( o<-> <..>6 wo::: 1-0:::~ Oz z<C <(<..> <..9-_J_J <(<( lO <D lO <D PROJECT NUMBER: P-SD-004050 z 1-0 => u; 0 5 5 w 0:: -' -' <( ;% en 0 0 "-"-0 ~ 0:: "-"- X X 0 0 :::;; :::;; <( <( en en "' "' ~ iii ~ Q "' 0 0 SCALE: 1"=80' VALID ONLY WHEN PLOffiD ANSI B 11" X 17" PV-1 L 1 PROPOSAL lAYOUT