HomeMy WebLinkAboutCDP 00-06; La Costa Downs Lot 9; Coastal Development Permit (CDP) (3)MEMORANDUM TO: GREG FISHER, ASSISTANT PLANNER FROM: Kathleen Farmer, Engineering Technician DATE: March 24, 2000 SUBJECT: CDP 00-06; CHRIS SALEM—6503 SURFSIDE COMPLETENESS & ISSUES REVIEW Engineering Department staff has completed a review of the above-referenced project for application completeness. The application and plans submitted for this proposed project are currently incomplete and unsuitable for further review due to the following incomplete items: 1. Show drainage pattern on site plan. Add the following note on site plan: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." 2. Show any existing and/or proposed slopes. 3. Inadequate information available on site plan to make a determination on grading requirements. Include accurate grading quantities, (cut, fill, import, and export.) 4. Show existing topography (include up to 20' beyond side property lines) and proposed finished grade. Show spot elevations throughout site plan. 5. Show finished elevation of residence and grade percentage of driveway. Show proposed width of driveway. 6. Show property dimensions, (all sides) and label on site plan. Site plan does not show City right-of-way has been dedicated. Provide title report. 7. Show any easement(s) on site plan. If you or the applicant have any questions, please either see or contact me at 602-2741. cc: Deputy City Engineering, Bob Wojcik