Loading...
HomeMy WebLinkAboutCDP 00-62; Hamilton Residence; Coastal Development Permit (CDP) (3)^. , •, FILE COPYCity of Carlsbad Planning Department PLANNING COMMISSION NOTICE OF DECISION June 25, 2001 John and Barbara Hamilton 2335 Pio Pico Carlsbad, CA 92008 SUBJECT: CDP 00-62 - HAMILTON RESIDENCE At the Planning Commission meeting of June 20, 2001, your application was considered. The Commission voted 5-0 (Compas/L'Heureux Absent) to APPROVE your request. The decision of the Planning Commission became final on June 20, 2001. The time within which judicial review of this decision must be sought is governed by Code of Civil Procedure, Section 1094.6, which has been made applicable in the City of Carlsbad by Carlsbad Municipal Code 1.16. Any petition or other paper seeking judicial review must be filed in the appropriate court not later than the ninetieth day following the date which this decision becomes final; however, if within ten days after the decision becomes final a request for the record of the proceedings accompanied by the required deposit in an amount sufficient to cover the estimated cost of preparation of such record, the time within which such petition may be filed in court is extended to not later than the thirtieth day following the date on which the record is either personally delivered or mailed to the party, or his attorney of record, if he has one. A written request for the preparation of the record of the proceedings shall be filed with the Planning Director, Michael J. Holzmiller, Secretary of the Planning Commission, 1635 Faraday Avenue, Carlsbad, CA 92008. If you have any questions regarding the final dispositions of your application, please call the Planning Department at (760) 602-4600. Sincerely, MICHAEL J. HOLZMILLER Planning Director MJH:GF:mh Enclosed: Planning Commission Resolution No. 5001 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us City of Carlsbad Planning Department May 29, 2001 John and Barbara Hamilton 2335 Pio Pico Carlsbad CA 92008 SUBJECT:CDP 00-62 - HAMILTON RESIDENCE The preliminary staff report for the above referenced project will be mailed to you on Friday, June 1, 2001. This preliminary report will be discussed by staff at the Development Coordinating Committee (DCC) meeting which will be held on June 11, 2001. A twenty (20) minute appointment has been set aside for you at 10:30. If you have any questions concerning your project you should attend the DCC meeting. It is necessary that you bring your required unmounted colored exhibit(s) with you to this meeting in order for your project to go forward to the Planning Commission. Your colored exhibits must be submitted at this time to ensure review by the Planning Commission at their briefings. If the colored exhibits are not available for their review, your project could be rescheduled to a later time. If you do not plan to attend this meeting, please make arrangements to have your colored exhibit(s) here by the scheduled time above. If you need additional information concerning this matter, please contact your Planner, Greg Fisher at (760) 602-4629. CITY QFi CARLSBAD uMry E. WAYNE/ Assistant Planning Director GEW:GF:cs c: File Copy 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us City of Carlsbad Planning Department May 15, 2001 John & Barbara Hamilton 2335 Pio Pico Drive Carlsbad Ca 92008 SUBJECT: CDP 00-62 - HAMILTON RESIDENCE Your application has been tentatively scheduled for a hearing by the Planning Commission on June 20, 2001. However, for this to occur, you must submit the additional items listed below. If the required items are not received by May 31, 2001, your project will be rescheduled for a later hearing. In the event the scheduled hearing date is the last available date for the City to comply with the Permit Streamlining Act, and the required items listed below have not been submitted, the project will be scheduled for denial. 1. Please submit the following plans: A) 10 copies of your (site plans, landscape plans, building elevation plans, floor plans) on 24" x 36" sheets of paper, stapled in complete sets folded into 8!/25 x 11" size. B) One SVz" x 11" copy of your reduced site plan, building elevation and floor plans. These copies must be of a quality which is photographically reproducible. Only essential data should be included on plans. 2. As required by Section 65091 of the California Government Code, please submit the following information needed for noticing and sign the enclosed form: A) 600' Owners List - a typewritten list of names and addresses of all property owners within a 600 foot radius of the subject property, including the applicant and/or owner. The list shall include the San Diego County Assessor's parcel number from the latest equalized assessment rolls. B) 100' Occupant List - (Coastal Development Permits Only) a typewritten list of names and addresses of all occupants within a 100 foot radius of the subject property, including the applicant and/or owner. C) Mailing Labels - one (1) separate set of mailing labels of the property owners within a 600 foot radius and occupants within a 100 foot radius of the subject property. The list must be typed in all CAPITAL LETTERS, left justified, void of any punctuation. For any address other than a single family residence, an apartment or suite number must be included but the Apartment, Suite and/or 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us CDP 00-62 - May 15, 2001 Page 2 HAMILTO™ESIDENCE Building Number must NOT appear in the street address line. DO NOT type assessor's parcel number on labels. DO NOT provide addressed envelopes - PROVIDE LABELS ONLY. Acceptable fonts are: Arial 11 pt, Arial Rounded MT Bold 9 pt, Courier 14 pt, Courier New 11 pt,), and MS Line Draw 11 pt. Sample labels are as follows: UNACCEPTABLE Mrs. Jane Smith 123 Magnolia Ave., Apt #3 Carlsbad, CA 92008 UNACCEPTABLE Mrs. Jane Smith 123 Magnolia Ave. Apt. #3 Carlsbad, CA 92008 ACCEPTABLE MRS JANE SMITH APT 3 123 MAGNOLIA AVE CARLSBAD CA 92008 C) D) Sincerely, Radius Map - a map to scale, not less than 1" = 200', showing all lots entirely and partially within 600 feet of the exterior boundaries of the subject property. Each of these lots should be consecutively numbered and correspond with the property owner's list. The scale of the map may be reduced to a scale acceptable to the Planning Director if the required scale is impractical. Fee - a fee (check payable to the City of Carlsbad) shall be paid for covering the cost of mailing notices. Such fee shall equal the current postage rate times the total number of labels. Cash and credit cards are also accepted. Greg Fi Assistant Planner GF:cs Attachment I HEREBY CERTIFY THAT THE PROPERTY OWNERS LIST AND LABELS SUBMITTED TO THE CITY OF CARLSBAD ON THIS DATE REPRESENT THE LATEST AVAILABLE INFORMATION FROM THE EQUALIZED ASSESSOR'S ROLES. APPLICATION NAME AND NUMBER CDP 00-62 - Hamilton Residence T'SJIEPRESENTATIVE RECEIVED BY DATE: ^jCj5pJp:62^Harn]ltonjancl u^reviewreport>& cpnditionj^doc _^^, Page J, CITY OF CARLSBAD ENGINEERING DEPARTMENT PROJECT REVIEW May 8, 2001 TO: Greg Fisher - Assistant Planner FROM: David Rick - Assistant Engineer - Development Services Division VIA: Senior Engineer - Development Services Division CDP 00-62: HAMILTON RESIDENCE PROJECT REPORT AND CONDITIONS TRANSMITTAL Engineering Department staff has completed the review of the above-referenced project and are recommending: X That the project be approved subject to the conditions as listed on the attached sheet. That the project be denied for the following reasons: X The following is a final Land Development Section project report for inclusion in the staff report for this project. DEVELOPMENT SERVICES DIVISION Project Report LOCATION: On the west side of Pio PJeoriear YourelfSt. BRIEF DESCRIPTION : A propo/ed 1,9f3\square foot single family residence on a 10,291 sq.ft. lot. ENGINEERING ISSUES AND DISCUSSION: Traffic and Circulation: Projected Average Daily Traffic (ADT): 10 A Traffic study was not required because of the projected low impacts imposed by a single family house. Comment: All ROW dedications are in place. Frontage improvements will not be built at this time and a NIA will be processed. review report & conditions.doc SEWER: Sewer District: Carlsbad Municipal Water District Sewer EDU's Required: 1 (1) edu/dwelling x 1 dwellings = 1 EDU's Comment: Sewer facilities exist in Pio Pico Dr. WATER: Water District: Carlsbad Municipal Water District GPD Required: 220gpd/edux1 edu's = 220 GPD Comment: No major water issues are associated with this proposed project. SOILS & GRADING: Quantities: 395 cy Cut: 0 cy Fill: 395 cy Export: 0 cy Import: 395 cy Permit required: Yes Off-site approval required: No Hillside grading requirements met: N/A Preliminary geo-technical investigation performed by: N/A Comment: Fill primarily used to establish grade between the pad and proposed retaining walls. The pad height will increase by only one to two feet. The fill will extend to 6 feet at the southwest corner of the lot. Otherwise, fill is limited to 3 feet or less throughout most of the lot. Landscaping of the crib wall shall be used to mitigate any visual impacts. DRAINAGE AND EROSION CONTROL: Drainage basin: A Preliminary hydrology study performed by: N/A Erosion Potential: Low Comment: Drainage will be diverted such that the time of concentration is increased to compensate for the increase in impervious surface. The drain inlets will also be constructed with an open gravel base to allow infiltration into the soil. Overflow from the drain box will flow out of a 3" pipe and discharge into a rip rap energy dissopator. LAND TITLE: Conflicts with existing easement: No Easements dedication required: No [Greg Fisher'^^cpp 00-62 Hamilton land ija&.review report & conditionslcloc Site boundary coincides with land title: Yes Comment: No major land title issues are associated with this project. IMPROVEMENTS: Off-site improvements: None required. Pio Pico is an alternative design street. The driveway will be graded to ultimate right-of-way grades to reduce costs and grading for future construction of Pio Pico Drive. The driveway will be constructed with AC to reduce costs of future removal. Standard variance required: None Comment: No major improvement issues are associated with this proposed project. ENGINEERING CONDITIONS OF APPROVAL ENGINEERING CONDITIONS NOTE: Unless specifically stated in the condition, all of the following conditions, upon the approval of this proposed tentative map, must be met prior to approval of a grading permit. 1. Prior to hauling dirt or construction materials to or from any proposed construction site within this project, Developer shall apply for and obtain approval from, the City Engineer for the proposed haul route. 2. Prior to issuance of any building permit, Developer shall comply with the requirements of the City's anti-graffiti program for wall treatments if and when such a program is formally established by the City. 3. Prior to occupancy, Developer shall install rain gutters to convey roof drainage to an approved drainage course or street to the satisfaction of the City Engineer. 4. Developer shall install sight distance corridors at all street intersections in accordance with Engineering Standards. 5. Prior to removing or relocating the palm tree located within the public right-of-way fronting Pio Pico Drive, and prior to issuance of a grading permit, the developer shall obtain a permit to remove or relocate said tree in accordance with Chapter 11.12 of the Carlsbad Municipal Code. Fees/Agreements 6. Developer shall cause property owner to execute and submit to the City Engineer for recordation the City's standard form Drainage Hold Harmless Agreement regarding drainage across the adjacent property. "V I. If the proposed development exceeds a building valuation of $75,000 as determined by the City Building Department at the time of issuance of building permit, developer shall cause property owner to enter into a "Neighborhood Improvement Agreement" with the City for the future public improvement of paving, base, sidewalks, curbs and gutters, driveway, pedestrian ramp, grading, undergrounding or relocation of utilities, a fire hydrant, a street light, and installation of sewer, storm drain and water systems prior to the issuance of a building permit. 8. Prior to approval of any grading or building permits for this project, Developer shall cause Owner to give written consent to the City Engineer to the annexation of the area shown within the boundaries of the subdivision into the existing City of Carlsbad Street Lighting and Landscaping District No. 1, on a form provided by the City Engineer. Grading 9. Based upon a review of the proposed grading and the grading quantities shown on the site plan, a grading permit for this project is required. Developer shall apply for and obtain a grading permit from the City Engineer prior to issuance of a building permit for the project. Coastal Conditions 10. If a Grading Permit is required, all grading activities shall be planned in units that can be completed by October 1st. Grading activities shall be limited to the "dry season", April 1st to October 1st of each year. Grading activities may be extended to November 15th upon written approval of the City Engineer, obtained in advance, and only if all erosion control measures are in place by October 1st. Dedications/Improvements I1. Developer shall have the entire drainage system designed, submitted to and approved by the City Engineer, to ensure that runoff resulting from 10-year frequency storms of 6 hours and 24 hours duration under developed conditions, are equal to or less than the runoff from a storm of the same frequency and duration under existing developed conditions. Both 6 hour and 24 hour storm durations shall be analyzed to determine the detention basin capacities necessary to accomplish the desired results. Water/Sewer 12. Prior to issuance of building permits, Developer shall pay all fees, deposits, and charges for connection to public facilities. Developer shall pay the San Diego County Water Authority capacity charge(s) prior to issuance of Building Permits. 13. This project is approved upon the express condition that building permits will not be issued for the development of the subject property, unless the Deputy City Engineer - Utilities has determined that adequate water and sewer facilities are available at the time of occupancy. •^^ —- City of Carlsbad Planning Department March 26, 2001 John and Barbara Hamilton 2335 Pio Pico Drive Carlsbad Ca 92008 SUBJECT: CDP 00-62 - HAMILTON RESIDENCE Your application for a Coastal Development Permit continues to be reviewed by the Planning and Engineering Departments. The application is complete. However, further issues need to be resolved or adequately addressed prior to staff making a determination on the proposed project. These issues must be addressed before this application can be scheduled for a hearing. Please contact your staff planner, Greg Fisher, at (760) 602-4629, if you have any questions or wish to set up a meeting to discuss the application. Sincerely, MICHAEL J. HOLZMILLER Planning Director MJH:GF:cs c: Chris DeCerbo David Rick Data Entry Planning Aide 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us LIST OF ITEMS NEEDED TO COMPLETE THE APPLICATION No. CDP 00-62 - Hamilton Residence Planning: None Engineering: None ISSUES OF CONCERN Planning: 1. Please provide a separate fence/wall plan showing all proposed walls and fencing. Include a detailed cross section. Do you propose a six foot fence on top of the proposed retaining walls along the side and rear property lines? As a reminder, the total height of all walls, fences and retaining walls, and combination fence/retaining walls cannot exceed six feet in height in a required side or rear yard setback (Policy 21). 2. As shown, the site plan is not clear and difficult to read. Please call me to discuss options prior to resubmitting. Engineering: 1. Some pavement is encroaching into the private utility easement located at the north end of the property. Provide a letter of permission to encroach from the easement holder. In addition, obtain written authorization from the property owner to the west to raise his retaining wall height and place fill on his lot. 2. Place the riprap energy dissipator located at the southwest end of the project within the property. 3. The project does not comply with some of the City's infill grading standards. These standards discourage retaining walls over 3 feet in height within 10 feet of the property line. Currently, walls up to 7.67 feet high are proposed. Also, any grading requiring over 100 cubic yards of import or export requires written justification subject to the City Engineer's approval. One hundred seventy cubic yards of import is proposed. Please address these issues. 4. On the site plan: a. Indicate the existing and proposed height of the retaining wall west of the subject property. b. Provide a cross section of the rear yard, including the neighbor's retaining wall. Also, provide a cross section of the retaining wall along the south property line. c. Show location of water service and sewer lateral. d. Show grades on site plan to reflect change in grade shown on Cross Section A-A. 5. Transition drainage which is concentrated at the edge of pavement to sheet flow away from street at the southeast end of the property. Enclosed is a redlined print to help you make your revisions. Please return this print with your next submittal. If you or the applicant has any questions, please either see or contact me at 602-2781. Memorandum TO: Greg Fisher-Assistant Planner FROM: David Rick -Assistant Engineer DATE: March 23, 2001 CDP 00-62 HAMILTON RESIDENCE COMPLETNESS AND ISSUES REVIEW Engineering Department staff has completed a review of the above-referenced project for engineering issues of concern. Engineering issues which need to be resolved or adequately addressed prior to staff making a determination on the proposed project are as follows: 1. Some pavement is encroaching into the private utility easement located at the north end of the property. Provide a letter of permission to encroach from the easement holder. In addition, obtain written authorization from the property owner to the west to raise his retaining wall height and place fill on his lot. 2. Place the riprap energy dissipator located at the southwest end of the project within the property. 3. The project does not comply with some of the City's infill grading standards. These standards discourage retaining walls over 3 feet in height within 10 feet of the property line. Currently, walls up to 7.67 feet high are proposed. Also, any grading requiring over 100 cubic yards of import or export requires written justification subject to the City Engineer's approval. One hundred seventy cubic yards of import is proposed. Please address these issues. 4. On the site plan; a. Indicate the existing and proposed height of the retaining wall west of the subject property. b. Provide a cross section of the rear yard, including the neighbor's retaining wall. Also, provide a cross section of the retaining wall along the south property line. c. Show location of water service and sewer lateral. d. Show grades on site plan to reflect change in grade shown on Cross Section A-A. 5. Transition drainage which is concentrated at the edge of pavement to sheet flow away from street at the southeast end of the property. Enclosed is a redlined print to help you make your revisions. Please return this print with your next submittal. If you or the applicant has any questions, please either see or contact me at 602-2781. DAVID RICK Assistant Engineer Engineering Development Services Division City of Carlsbad Planning Department January 3, 2001 John & Barbara Hamilton 2335 Pio Pico Drive Carlsbad, Ca 92008 SUBJECT: CDP 00-62 - HAMILTON RESIDENCE Thank you for applying for Land Use Permits in the City of Carlsbad. The Planning Department has reviewed your Coastal Development Permit, application no. CDP 00-63 - Hamilton Residence, as to its completeness for processing. The application is complete, as submitted. Although the initial processing of your application may have already begun, the technical acceptance date is acknowledged by the date of this communication. The City may, in the course of processing the application, request that you clarify, amplify, correct, or otherwise, supplement the basic information required for the application. In addition, you should also be aware that various design issues may exist. These issues must be addressed before this application can be scheduled for a hearing. The Planning Department will begin processing your application as of the date of this communication. Please contact your staff planner, Greg Fisher, at (760) 602-4629, if you have any questions or wish to set up a meeting to discuss the application. Sincerely, MICHAEL J. HOLZMILLER Planning Director MJH:GF:cs Chris DeCerbo David Rick $\\e Cop f Data Entry Planning Aide 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us LIST OF ITEMS NEEDED TO COMPLETE THE APPLICATION No. CDP 00-62 - Hamilton Residence Planning: None Engineering: None ISSUES OF CONCERN Planning: 1. Please provide the maximum height on all elevations. As shown, it appears that the proposed building height slightly exceeds the maximum allowed height of 24 feet for a roof pitch less than 3:1 2. Engineering: 1. Some pavement is encroaching into the private utility easement located at the north end of the property. Provide a letter of permission to encroach from the easement holder. In addition, please verify the width of the easement. According to county- recorded doc #2000-0274481, the width of the easement is 6 feet, not 5 feet as shown on the site plan. 2. This project will be conditioned to require the property owner to enter into a "Neighborhood Improvement Agreement" in lieu of installing street and sidewalk improvements on Pio Pico Drive and a potential future street fronting the south side of the property. This comment is for informational purposes and no response is necessary. 3. At the rear of the lot, drainage is shown to flow southward toward the southwest corner of the lot. However, the topography shown does not support this direction of flow. Please clarify whether the contour lines shown on the site plan are existing or proposed? If any changes in the grade are proposed, then show said changes. Also, provide spot elevations to identify proposed topography, especially at the rear of the lot. Provide percent grade next to each drainage arrow. If drainage is to concentrate at the southwest corner of the property as currently shown on the site plan, then show detail of how this drainage will be concentrated and how the increased energy from these concentrated flows will be controlled (i.e. threw an energy dissipator). One option to consider is to place a berm and unlined swale parallel with the western property line and direct drainage at a low grade (i.e. one percent grade if achievable) to a drain inlet at the corner of the property. The pipe to this inlet could daylight at the base of the slope and discharge into a riprap energy dissipator or longitudinal perforated pipe, all which must be placed within the property. Another option to consider is placing a small detention basin at the southwest corner of the property. Whatever design is used, the post development rate of runoff cannot exceed the existing rate of runoff. 4. If any grading is proposed, regardless of how insignificant, provide quantities in cubic yards. Also, illustrate the change of grade on the site plan. 5. On the site plan; A. Show the neighbor's retaining wall to the west and indicate its height. B. Add the pad elevations of the garage and dwelling. C. Provide a cross section of the rear yard, including the neighbor's retaining wall. D. Add a brief legal description. E. Show location of water service and sewer lateral. F. Provide street cross section of Pio Pico Drive, identifying right-of-way width, edge of pavement, and street centerline. Enclosed is a redlined print to help you make your revisions. Please return this print with your next submittal. Memorandum TO: Greg Fisher-Assistant Planner FROM: David Rick -Assistant Engineer DATE: January 2, 2001 CDP 00-62 HAMILTON RESIDENCE COMPLETNESS AND ISSUES REVIEW Engineering Department staff has completed a review of the above-referenced project for completeness and engineering issues of concern. All items needed for engineering review are provided for determining the application as complete. Engineering issues which need to be resolved or adequately addressed prior to staff making a determination on the proposed project are as follows: 1. Some pavement is encroaching into the private utility easement located at the north end of the property. Provide a letter of permission to encroach from the easement holder. In addition, please verify the width of the easement. According to county-recorded doc #2000-0274481, the width of the easement is 6 feet, not 5 feet as shown on the site plan. 2. This project will be conditioned to require the property owner to enter into a "Neighborhood Improvement Agreement" in lieu of installing street and sidewalk improvements on Pio Pico Drive and a potential future street fronting the south side of the property. This comment is for informational purposes and no response is necessary. 3. At the rear of the lot, drainage is shown to flow southward toward the southwest corner of the lot. However, the topography shown does not support this direction of flow. Please clarify whether the contour lines shown on the site plan are existing or proposed? If any changes in the grade are proposed, then show said changes. Also, provide spot elevations to identify proposed topography, especially at the rear of the lot. Provide percent grade next to each drainage arrow. If drainage is to concentrate at the southwest corner of the property as currently shown on the site plan, then show detail of how this drainage will be concentrated and how the increased energy from these concentrated flows will be controlled (i.e. threw an energy dissipator). One option to consider is to place a berm and unlined swale parallel with the western property line and direct drainage at a low grade (i.e. one percent grade if achievable) to a drain inlet at the corner of the property. The pipe to this inlet could daylight at the base of the slope and discharge into a riprap energy dissipator or longitudinal perforated pipe, all which must be placed within the property. Another option to consider is placing a small detention basin at the southwest corner of the property. Whatever design is used, the post development rate of runoff cannot exceed the existing rate of runoff. 4. If any grading is proposed, regardless of how insignificant, provide quantities in cubic yards. Also, illustrate the change of grade on the site plan. 5. On the site plan; a. Show the neighbor's retaining wall to the west and indicate its height. b. Add the pad elevations of the garage and dwelling. c. Provide a cross section of the rear yard, including the neighbor's retaining wall. d. Add a brief legal description. e. Show location of water service and sewer lateral. f. Provide street cross section of Pio Pico Drive, identifying right-of-way width, edge of pavement, and street centerline. Enclosed is a redlined print to help you make your revisions. Please return this print with your next submittal. If you or the applicant has any questions, please either see or contact me at 602-2781. DAVID RICK Assistant Engineer Engineering Development Services Division