Subject: Geotechnical Update, Proposed Redevelopment of 2531 - 2589 State
Street, Carlsbad, California
References: California Building Standards Commission (CBSC), 2013, California
Building Code (CBC)
Leighton and Associates, Inc., 2005, Preliminary Geotechnical
Investigation, Proposed Redevelopment of 2531, 2541, and 2551 State
Street, Carlsbad, California, Project No. 041742-001, dated December 7,
2005
Leighton and Associates, Inc., 2014, Phase I and Limited Phase II
Environmental Site Assessment for 2531 through 2601 State Street,
Carlsbad, California, Project No. 10552.001, dated January 9, 2014
RBF Consulting, 2014, Preliminary Grading Plans for State Street
Townhomes, Carlsbad, California, Sheet C5, dated January 2014
In accordance with your authorization, this letter presents Leighton's geotechnical
update for the proposed State Street residential redevelopment, located at 2531 -2589
State Street, in Carlsbad, California. The purpose of this update study was to review our
previous geotechnical report and site environmental documentation (Leighton, 2006 and
2014), and to provide seismic design parameters in accordance with the 2013 CBC. We
also performed a site visit on January 31, 2014 to observe current conditions. Currently,
the site, approximately 1.89 acres, is utilized as commercial and light industrial property.
3934 Murphy Canyon Road, Suite B205 • San Diego, OA 92123-4425
858.292.8030 • Fax 858.292.0771 •www.leightongeo.com
10552.004
As background, Leighton performed the Initial geotechnical investigation of the subject
site in 2005 (Leighton, 2005). Recently, Leighton performed a Phase I and Limited
Phase II Environmental Site Assessment (ESA) Report for the site. The purpose of the
Limited Phase II ESA was to assess the soil and soil vapor throughout the subject site
for the presence of contaminants originating from current and historical site uses, such
that the potential health risks can be evaluated prior to residential development. The
environmental study included eight (8) subsurface borings across the subject site. For
the findings and results of the environmental study, please refer to referenced document
(Leighton, 2014).
Based on our understanding of the site conditions and review of the referenced
geotechnical and environmental documents, the geotechnical conditions of the subject
site have not changed. Therefore, it is our professional opinion that the geotechnical
recommendations presented in the referenced geotechnical report are still applicable for
its intended use, provided the following recommendations are incorporated into the
design and construction ofthe proposed buildings and improvements.
In addition, the following items should be noted:
• The undocumented fill associated with the former development is potentially
compressible and should be removed down to the dense competent formation
material. The depth ofthe removal is generally anticipated to be on the order of 3
to 5 feet below the existing ground surface. However, deeper undocumented fill
associated with buried utilities, old septic systems, basements and underground
storage tanks should be anticipated.
• Impacted soil may be encountered during grading. Please refer to the referenced
environmental study (Leighton, 2014). Note that special handling and waste
profiling may be required for the excavation and disposal ofthis impacted soil.
Seismicitv
The following seismic design parameters for the site (latitude 33.164299,
longitude-117.35299) are the risk-targeted spectral acceleration parameters for the
project determined in accordance with the 2013 California Building Code (CBSC, 2013)
and the USGS Worldwide Seismic Design Values tool (Version 3.1.0).
4 -2-
Leighton
10552.004
Table 2
2013 CBC Risk-Targeted Mapped Spectral Acceleration Parameters
Site Class D
Site Coefficients Fa = 1.035
Fv = 1.554
Mapped MCER Spectral Accelerations Ss = 1.163g
Si = 0.446g
Site Modified MCER Spectral Accelerations SMS = 1.203g
SMI = 0.693g
Design Spectral Accelerations SDS = 0.802g
SDI = 0.462g
Utilizing ASCE Standard 7-10, in accordance with Section 11.8.3, the following
additional parameters for the peak horizontal ground acceleration are associated with
the Geometric Mean Maximum Considered Earthquake (MCEQ). The mapped MCEG
peak ground acceleration (PGA) is 0.463g for the site. For a Site Class D, the FPGA is
1.037 and the mapped peak ground acceleration adjusted for Site Class effects (PGAM)
is 0.48g for the site.
Site Grading
All undocumented fill associated with the former development should be removed down
to the dense competent formation material. To reduce the potential for differential
settlement beneath the proposed buildings (i.e., cut/fill transitions), we recommend the
entire buiiding pad be overexcavated at least 3 feet below the lowest foundation and
replaced with properly compacted fill. In addition, we recommend that the overexcavation
extend laterally at least 10 feet beyond the building perimeter or footprint.
Imported soil, if needed to raise the site grades, should be granular and have an
expansion index less than 50 (per ASTM Test Method D4829). Import soils and/or the
borrow site should be evaluated by the geotechnical consultant prior to importation.
Leighton
10552.004
Foundation and Slab Desian for Residential Buildings
The proposed residential buildings may be supported by conventional, continuous or
isolated spread footings. Footings should extend a minimum of 24 inches beneath the
lowest adjacent soil grade. At these depths, footings may be designed for a maximum
allowable bearing pressure of 2,000 pounds per square foot (psf) if founded in properly
compacted fill soils. The allowable pressures may be increased by one-third when
considering loads of short duration such as wind or seismic forces. The minimum
recommended width of footings is 18 inches for continuous footings and 24 inches for
square or round footings.
The interior and garage slab-on-grade floors for the residential buildings should be at
least 4 inches and 5 inches thick, respectively, and be reinforced with No. 3 rebars 18
inches on center, each way (minimum), placed at mid-height in the slab. Slabs should
be underlain by a 2-inch layer of clean sand (sand equivalent greater than 30), which is
in-turn underlain by a minimum 10-mil plastic sheeting (moisture barrier) and an
additional 2 inches of clean sand. We recommend that control joints be provided across
the slab at appropriate intervals as designed by the project architect. Some moisture
sensitive flooring may require additional measures to mitigate moisture migration
through the slab as designed by the project architect.
Limitations
Recommendations contained in this limited report are based on our site
reconnaissance, background review, and present knowledge of the proposed
construction. It is possible that soil conditions vary between or beyond the points
explored. If soil conditions are encountered during grading or foundation excavation,
which differ from those described in the original geotechnical reports, our firm should be
notified immediately in order that a review may be made and any supplemental
recommendations provided.
Our firm has performed our services in substantial accordance with the generally
accepted geotechnical engineering practice as it exists in the site area at the time of our
study. No warranty is made or intended.
4 -4-
Leighton
10552.004
We appreciate the opportunity to be of service on this project. Should you have any
questions related to this report, please contact our office at your convenience.
Respectfully submitted,
LEIGHTON and ASSOCIATES, INC
William D. Olson, RCE 45283
Associate Engineer
Michael R. Stewart, CEG 1349
Vice President / Principal Geologist