Loading...
HomeMy WebLinkAboutCT 93-10; Seapointe Resort; Tentative Map (CT) (23)January 16, 1995 ^ Carlsbbd Municipal Water District 5950 El Camino Real, Carlsbad, CA 92008 Engineering: (619) 438-3367 Administration: (619) 438-2722 Fax: (619) 431-1601 George O'Day O'Day Consultants 7220 Avenida Encinas Suite 204 Carlsbad, California 92009 SUBJECT: SEAPOINTE RESORT, C.T. NO. 93-10 - CMWD PROJECT NO. 94-202 Dear George: The District has completed the potable water, sewer and reclaimed water analysis on subject project and has established the following conditions: POTABLE WATER SYSTEM 1. Install a 12" diameter line in Anacapa Road from La Costa Blvd. northerly to proposed cul de sac. 2. Install a 12" diameter line in Descanso Blvd. from Anacapa Road. 3. Install a 12" diameter line in Carlsbad Blvd. from Descanso Blvd. northerly approximately 650 feet. Included in this item is a future pressure regulating station. Developer shall provide a site off the roadway and sidewalk area and will provide a level, graded, vehicular accessible 20' wide X 40' long area and install electrical, telephone and pressure relief discharge drain appurtenances. 4. Install 6 -12" gate valves (as shown). 5. Install 2 fire hydrant assemblies (as shown). 'Serving Carlsbad for over 35 years" Page 2 George O'Day, O'Day Consultants January 16, 1995 6. Install 2 future fire hydrant stubs in Anacapa Road (as shown). (See City improvement plan La Costa Downs, SP-201, Dwg. No. 331-8, Sheet 1 of 4). Stub shall include 12" X 6" tee, 6" FL. G.V. and 6" BL. FL. 7. The 12" line in Anacapa Road must agree with the City's approved La Costa Downs SP- 201, Dwg. No. 331-8 plans to insure no conflicts horizontally or vertically. The Developer can request in writing that the District review reimbursement possibilities for this project. SEWER SYSTEM 1. Install an 8" gravity line in Franciscan Road from La Costa Blvd. to Descanso Blvd. 2. Install an 8" gravity line in Descanso Blvd. from Franciscan Road to Anacapa Road. 3. Install an 8" gravity line in Anacapa Road from Descanso Blvd northerly to cul de sac. 4. The gravity 8" line must agree with the City's approved La Costa Downs SP-201, Dwg. No. 331-8 plans to insure no conflicts horizontally or vertically. RRTT.AlMtD lyATKR SYSTEM 1. There is no public system required. 2. Developer will install private system for future reclaimed water use. If you have any questions, please contact the undersigned. Very truly yours, William E. Plummer, P.E. District Engineer WEP:jm CC: Christer Westman, City Planning Dept. Ben Ellorin, City Engineer '"" #77 $ S./: RRILRORD (MORTHBOWD) CRRLSBRD CASEMENT TABLE TITLE COHPANT PRELIMINARY TITLE REPORT C.MW.D* PART ITEM FORPOSE ONHER RET 2' POLE EASEMENT SDGtE ' Sf 722/138 3/14/17 REMAI* POLE I PIPE LINES K.H. ELLIS BK 1589/30 2/21/29 REMAIN (LOCATION ONKNOWI) ** ISl9H»iSI tf/3/tt 4BMMT POLE EASEMENT SOGIE BX 4254/254 10/4/51 REMAIN ACCESS RIGHTS BX 4332/306 12/31/91 HOD I FT PIPELINE SDGtE BX 4341/481 1/11/52 REMAIN SEWER CARLSBAD FILE NO. 44080 3/15/68 REMAIN PIPELINE • STATE CA FILE HO. 181479 10/17/68 REMAIN sW *&' * CMWD? PART C.T. NO. 93-10 Jt-\w EXIST. W"S£U£ir ftP iCUO-SfU£lf HI. z TENTATIVE MAP FOR SEAPOINTE RESORTCAKLS0AD COWOIT«HT3 NOV15S94 DATE PRINTED REVISED 8-2-94REVISED 7-19-94REVISED 6-30-94REVISED 6-6-94 REVISED 3-14-94 . /s CMWO? PART t*C.T. NO. 93-HO 34-2OZ