HomeMy WebLinkAboutCT 94-04; Poinsettia Shores PA 1; Tentative Map (CT) (13)JANUARY 23, 1995 TO: ASSOCIATE PLANNER, ERIC MUNOZ FROM: Associate Engineer, Davis VIA: PRINCIPAL CIVIL ENGINEER FOR LAND USE CT 94-04, PUD 94-03, POINSETTIA SHORES PLANNING AREA A-1 we have reviewed the last submittal. we have identified some issues that need resolution. When these issues are resolved we will be able to finalize our conditions of approval that have already been drafted. The issues follow: 1. The elevations of the pads adjacent to Area B-1, Lot 5 average approximately five feet above the Area B-1 elevations. No slope or retaining wall is shown on either this tentative map or the last submitted TM for are B-1. we will not be able to support a resolution that has a slope on the existing drainage easement between the two areas. 2. Show a method of obtaining fail safe overflow from the northwest corner of this project, it appears that street "B" in Area B-1 will need to be the fail safe path for overflow from this project, Area A-1. Also it appears that failsafe overflow for Area B-1 will need to be the railroad right-of-way. A hold harmless agreement regarding drainage will be needed for both areas. H:\library\eng\wpdata\davis\ct942lss.grd.