TO: ANNE HYSONG, ASSOCIATE PLANNER
FROM: Associate Engineer Quon
COMPLETENESS REVIEW AND INITIAL ISSUES STATEMENT
WORTHING SUBDIVISION, CT 98-16
The Engineering Department has completed its review of the subject project for application
completeness. The application and plans submitted for this project are incomplete and
unsuitable for further engineering review due to the following missing or incomplete items:
1 . Lot line dimensions on Lot 1 .
In addition, the Engineering Department made a preliminary review of the project for
Engineering issues. Engineering issues which need to be resolved or adequately addressed
prior to conditioning of the project are as follows:
1. Existing and proposed right-of-way widths for both Buena Vista Avenue and James
Drive, along with proposed dedications, should be clearly shown on the tentative map.
2. The plan view appears to show curb, gutter, and sidewalk on the west side of James
Drive to be included with this project, while the typical street section shows these
improvements to be done in the future. Please clarify.
3. The right-of-way width for James Drive can be reduced to 56', with a curb-to-curb width
of 36'. Required street improvements will be half-street width plus 12' of additional
paving.
4. The minimum grade of James Drive is to be 1%, as opposed to the 0.5% proposed on
the plans.
5. It is unclear as to why the Line Data tables and Curve Data tables are shown on the
tentative map.
Attached is a redlined check print set of the project. Please forward this plan set to the
applicant for corrections and changes as noted. The applicant must return this plan set with the
corrected plans to assist us in our continued review. If you have questions regarding any of the
comments above, please contact me at extension 4380.
KENNETH W. QUON
Associate Engineer
c: Public Works Director
Bob Wojcik, Principal Civil Engineer
COMMUNITY: WORTHING ENG ISSUES