HomeMy WebLinkAboutCT 98-17; Hadley Property; Tentative Map (CT) (21)W Date: May 3. 1999 Planning Department City of Carlsbad 2075 Las Palmas Drive Carlsbad, California 92009 TO: Van Lynch FROM: Kelly Efimoff CMWD NO. 99-510 SUBJECT: Hadlev Property CT 98-17 The District is providing conditions on the subject project dated April 14. 1999. The District has reviewed the subject project, based on our review of the project, we have the following conditions regarding potable water, recycled water and sewer systems: 1. Sequentially, the Developer's Engineer should do the following: A. Meet with the City Fire Marshal and establish the fire protection requirements. B. Prepare and submit a colored recycled water use area map and submit this map to the Planning Department for processing and approval by the District Engineer. C. Prior to the preparation of sewer, water and recycled water improvement plans, the Developer shall submit preliminary system layouts to the District Engineer for review, comment and approval. 2. The Developer will be expected to provide detailed information to the District Engineer regarding water demand, irrigation demand, fire flow demand in gallons Page 2 "**- ^ Planning Department Date: May 3, 1999 per minute, and projected sewer flow in million gallons per day at the time of first formal plan check submittal. 3. The entire potable water system, recycled water system and sewer system shall be evaluated in detail by Developer and District Engineer to insure that adequate capacity, pressure and flow demands can be met. The Developer/Developer's Engineer shall meet with the District Engineer or his representative for a preliminary review of potable water, recycled water and sewer facility requirements. 4. All District pipelines, pump stations, pressure reducing stations and appurtenances required for this project by the District shall be within public right- of-way or within minimum 20-foot wide easements granted to the District or the City of Carlsbad (minimum 30-foot wide for General Utility easements). 5. All potable water and recycled water meters shall be placed within public right of way. 6. No more than 19 homes shall be served on a single potable water distribution pipeline. For those locations with more than 19 homes, a looped potable water pipeline system shall be designed for each pressure zone. The Developer will be required to provide a connection to the potable water system in "G" Street, Aviara Phase III and in Black Rail Road. 7. The Developer will be required to provide and obtain a minimum 20-foot wide sewer easement for sewer main necessary to serve the east end of the subject property. The sewer will connect to the existing sewer main in "G" Street, Aviara Phase III. The water and sewer connections to "G" Street may be provided for within a 30-foot General Utility easement with the approval of the District Engineer. If you have any questions, please contact the undersigned. Kelly Efimoff Associate Engineer KJE:kje DENSITY CALC