Loading...
HomeMy WebLinkAboutCT 99-01; Carlsbad Beach Estates; Tentative Map (CT) (21)Merit Group, Inc. 2171 El Camino Real, Suite 202, Oceanside, CA 92054 Tel: (760)721-6499 Fax: (760)721-6498 December 15,1999 Ms. Elaine Blackburn CITY OF CARLSBAD PLANNING DEPARTMENT 2075 La Palmas Drive Carlsbad, California 92009-1576 SUBJECT: CT 99-01/SDP 99-02/PUD 99-01/CDP 99-02 - CARLSBAD BEACH ESTATES CORRECTED PAGES PER YOUR CONVERSATIONS WITH THE ARCHITECT AND ENGINEER. Dear Elaine: I hope these changes make our project compliant to your satisfaction. Sincerely, MERIT GROUP, INC. H. David Buckmaster President Enclosures: 1 . 5 Sets of corrected pages from civil engineer 2. 5 Sets of corrected pages from architect 3. 1 Architectural Guideline Compliance Summary ARCHITECTURAL GUIDELINE COMPLIANCE SUMMARY CARLSBAD BEACH ESTATES GUIDELINE 1 . Where (3) two-story units occur in a row and they are situated less than 15 feet apart, at least one unit must have a single-story building edge not less than 10 feet in depth. 2. Where (3) two-story units occur in a row and they are situated 15 to 20 feet apart, at least one unit must have a single-story building edge not less than 5 feet in depth. 3. Per project, 33% of all units shall have a single- story building edge a minimum of 40% of the total perimeter. 4. Per project, 50% of all units with a lot frontage greater than 45 feet must have 4 separate building planes on the front elevation. 5. Per project, 50% of all units with a lot frontage greate than 45' must have four separate building planes on the street side elevation. 6. Per project, 50% of all units shall have one side elevation with a 7' average sideyard setback 7. Three-car garages are limited to 75% of the total units where average lot size is 5,000 s.f. or less. Three-car garages shall incorporate a mixture of 2-door, 30-door and 2-door offset designs. 8. 50% of exterior door and window openings shall be projected or recessed a minimum of 2 inches. WIN. STD. N/A N/A 1of4 N/A • N/A 2of4 3of4 RESULTS Unit B at Lots 2 and 3 have a single-story building edge 12 feet deep at the first floor, which exceeds standards. Unit A at Lot 1 is more than 20 feet away from Unit B at Lot 2. Lots 2 and 3 each have a 12 foot deep single-story building edge, which exceeds standards. Of the four units, the Lot 4 unit is 100% single-story, exceeding the standard. Units at Lots 2 and 3 are 37% single-story, which exceeds the standard beyond the min. reqmt. Lot 4 exceeds 45' but is existing with two building planes. Lot 1 is new and has three planes but has less than 45' of frontage. Lots 2 and 3 have less than 45' frontage but have four planes each. All exceed the standard. Lot 4 exceeds 45' frontage, but has no street side elevation. Lot 1 does not exceed 45' Frontage but has four planes on the street side elevation. Lot 2 does not exceed 45' frontage but has five planes on the street side elevation. All exceed the standard. Lot 1 has one side elevation with a 7 foot setback. Lot 4 has one side elevation with an 1 1' average sideyard setback, exceeding the standard. No three-car garages are proposed, exceeding the standard. 100% of exterior door and window openings are recessed 2 inches, exceeding the std..