Loading...
HomeMy WebLinkAboutCT 99-08; Spyglass II; Tentative Map (CT) (76)COMMENTS Date: July 27.1999 Planning Department City of Carlsbad 2075 Las Palmas Drive Carlsbad, California 92009 TO: FROM: Van Lynch Kelly Weaver Efimoff CMWD NO. 89-C.310 SUBJECT: Spyglass SDP 99-04/SUP 99-04/TM 99-08 APN 167-090-69 Corner Carlsbad Village Drive and El Camino Real The District is responding to the Review and Comment Memo dated June 28. 1999. We are unable to further clarify issues identified in our Comment Memo dated April 6, 1999 because the Developer has not provided any additional information in response to our concerns. All comments made in the April Memo still apply. The following is a brief summary of significant issues which should be resolved prior to conditioning: 4. All District pipelines, pump stations, pressure reducing stations and appurtenances required for this project by the District shall be within public right- of-way or within minimum 20' wide easements granted to the District or the City of Carlsbad. A wider easement may be required for the sewer running down the hillside into El Camino Real. 5. Sequentially, the Developer's Engineer shall do the following: A. Meet with the City Fire Marshal and establish the fire protection requirements. Page 2 Planning Department Date: April 6, 1999 B. Prepare and submit a colored recycled water use area map and submit this map to the Planning Department for processing and approval by the District. C. Prior to the preparation of sewer, water and recycled water improvement plans, the Developer shall submit preliminary system layouts to the District for review, comment and approval. 5. All potable water and recycled water meters shall be placed within public right of way. The Developer will be responsible for showing the locations of such meters in relationship to the driveways and the edge of right of way. All sewer cleanouts shall be placed at property line in a location approved by the District. 6. No more than 19 homes shall be served on a single potable water distribution pipeline. The connections for the looped pipeline system will include a connection in Appian Way and in Carlsbad Village Drive. The Developer will be responsible for construction of sufficient potable water pipeline in Carlsbad Village Drive to connect to the existing 446 HGL Zone near the intersection of El Camino Real. 7. The Developer will be responsible for connecting to the existing sewer system in Carlsbad Village Drive. If you have any questions, please contact the undersigned. Kelly Efimoff Associate Engineer KJE:kje