HomeMy WebLinkAboutCUP 00-17B; North Coast Christian Fellowship; Conditional Use Permit (CUP) (3)CITY OF CARLSBAD REVIEW AND COMMENT MEMO DATE: September 27, 2001 REVISED PLANS 0 * * * * * * TO: ENGINEERING DEPARTMENT POLICE DEPARTMENT - ATTN: J. SASWAY FIRE DEPARTMENT - MIKE SMITH BUILDING DEPARTMENT - PAT KELLEY RECREATION - MARK STEYAERT PUBLIC WORKS DEPARTMENT (STREETS) - HEIDI HEISTERMAN LANDSCAPE PLANCHECK CONSULTANT - LARRY BLACK NORTH COUNTY TRANSIT DISTRICT - PLANNING DEPARTMENT SEMPRA ENERGY - LAND MANAGEMENT WATER DISTRICT * Carlsbad * * * Carlsbad SCHOOL DISTRICT * CALTRANS (send anything adjacent to 1-5) Always Send Exhibits * FROM: Planning Department REQUEST FOR REVIEW AND COMMENT ON APPLICATION NO. CUP 00-17 (B) NOTE: Please use this number on all correspondence. PROJECT TITLE: North Coast Christian Fellowship Staff Contracting Inc. APPLICANT: PROPOSAL: Two modular structures for classrooms Please review and submit written comments and/or conditions to , the Project Planner in the Planning Department at 1635 Faraday Avenue, by NOV. 12,2001 . (If you have “No Comments”, please so state.) If not received by the date indicated, it will be assumed that you have no comment and the proposal has your endorsement as submitted. If you have any questions, please contact Christer Westman at 602- 4614 . The request for conditions will follow at the appropriate time. Christer Westman PLANS ATTACHED FRM0020 06/01 (8. --/;; CII .,a CARLSBAD REVIEW AND COMME T MEMO c/ A7 Q( DATE: September 27, 2001 TO: ENGINEERING DEPARTMENT * * * POLICE DEPARTMENT - ATTN: J. SAS FIRE DEPARTMENT - MIKE SMITH * * * * * * * * * BUILDING DEPARTMENT - PAT KELLEY %‘ i ,‘ RECREATION - MARK STEYAERT PUBLIC WORKS DEPARTMENT (STREETS) - HEIDI HEISTERMAN Car lsbad WATER DISTRICT LANDSCAPE PLANCHECK CONSULTANT - LARRY ‘BLACK Carlsbad SCHOOL DISTRICT NORTH COUNTY TRANSIT DISTRICT - PLANNING DEPARTMENT SEMPRA ENERGY - LAND MANAGEMENT CALTRANS (send anything adjacent to 1-5) Always Send Exhibits FROM: Planning Department REQUEST FOR REVIEW AND COMMENT ON APPLICATION NO. CUP 00-17 (B) NOTE: Please use this number on all CorresDondence. PROJECT TITLE: North Coast Christian Fellowship Staff Contracting Inc. APPLICANT: PROPOSAL: Two modular structures for classrooms Please review and submit written comments and/or conditions to ! the Project Planner in the Planning Department at 1635 Faraday Avenue, by NOV. 12,2001 . (If you have “No Comments”, please so state.) If not received by the date indicated, it will be assumed that you have no comment and the proposal has your endorsement as submitted. If you have any questions, please contact Christer Westman at 602- 4614 . The request for conditions will follow at the appropriate time. Christer Westman THANK YOU COMMENTS: PLANS ATTACHED FRM0020 06/01 CARLSBAD FIRE DEPARTMENT Fire Protection Services PRELIMINARY REVIEW REPORT PROJECT NAME: North Coast Christian Fellowship 3254 Eureka Place Date: March 13, 2002 Project number: CUP 00-17 (B) Preliminary comments: (Note: This commentary identifies missing information that must be included with the official project submittal. It may also identify fire protection issues associated with the project.) Fire Department access roadway per CFC Section 902.2.1 is required to provide access within 150 feet of all portions of the exterior walls of both classrooms. A fire hydrant must be available within 150 feet of all portions of the exterior walls of both classrooms. The hydrant may be on the public street or on-site. Provide a site plan showing all existing nearby hydrants. If instruction is provided for more than four hours in one day or 12 hours per week, the classrooms will be classified as an “E” occupancy. All E occupancies must be provided with a manual fire alarm system per CBC 305.9. la. DEPARTMENT OF PUBLIC WORKS ENGINEERING/DEVELOPMENT SERVICES MEMORANDUM September 5,2001 TO: SENIOR PLANNER - CHRISTER WESTMAN FROM: Project Engineer - Engineering/Development Services CUP 00-178: NORTH COAST SEVENTH DAY ADVENTISTS COMPLETENESS REVIEW & INITIAL ISSUES STATEMENT Engineering Department staff have completed a review of the above-referenced project for application completeness. The application is complete as submitted. However, prior to staff making a determination on the project, the following engineering issues of concern must be adequately resolved/addressed: Traffic & Transportation 1. Please add a typical street cross-section to the site plan for Eureka Place. 2. Please be advised, a Neighborhood Improvement Agreement (NIA) will be required for the potential future street improvements along the project‘s Eureka Drive frontage, as a condition of approval for the project. Improvements & Utilities 1. Please label all existing surface improvements (i.e., street light standards, sidewalks, etc.) and surface, and subsutface, utilities (i.e., sewer laterals, waterlines, cleanouts, etc). 2. Please show existing fire hydrants located within and adjacent to the project. 3. Are there any restrooms provided in the two new coaches? If so, please show how sewer and water facilities will be accessed. 4. Please supply documentation from the City Fire Marshall that not sprinkling the two new coaches is acceptable. Land Title & Mapping 1. Please be advised, a 5ft. street dedication will be required along the project’s Eureka Place frontage, as a condition of approval for the project. 2. Please show all easements and encumbrances as indicated in Schedule “B” of the Preliminary Title Report (PR). Schedule “B” Item No. 4, indicates that there may be some existing easements and servitudes. These encumbrances must be listed in Schedule “B,” or, this item should be removed from the PR, if there are know easements or encumbrance. Also, please label the future dispositions of any easements and encumbrances (e.g., “to remain,” quitclaim,” etc.). I. b CUP 00-17B: NORTH COAT SEVENTH DAY ADVENTISTS COMPLETENESS REVIEW & INITIAL ISSUSE STATEMENT C. WESTMAN MEMO; SEPTEMBER 5,2001 Gradinn & Drainage 2 1. Please indicate the amount of grading proposed for the project. If no grading is being proposed, then indicate this on the site plan. M iscel I aneou s 1. Please show how National Pollutant Discharge Elimination System (NPDES) and San Diego Regional Water Quality Control Board (SDRWQCB) criteria will be met. This shall include utilizing Best Management Practices to eliminate or reduce on-site surface pollutants. Please submit a preliminary Storm Water Pollution Prevention Plan (SWPPP) that is in compliance with current requirements and provisions established by the SDRWQCB. The SWPPP shall address measures to reduce, to the maximum extent possible, storm water pollutant runoff at both construction and post-construction phases of the project. At a minimum, the plan shall: a) Identify existing and post-development on-site pollutants; b) Recommend source control Best Management Practices (BMP’s) to filter said pollutants (buy utilizing a combination of vegetated swales, filters, oil/water separators, etc.); c) Establish specific procedures for handling spills and routine clean up. Special considerations and effort shall be applied to employee education on the proper procedures for handling clean up and disposal of pollutants; d) Ensure long-term maintenance of all post constructed BMP’s in perpetuity; * Please be advised, pollutant mitigation is major staff issue of concern. 2. Enclosed is a redlined check print of the proposed project. This check print must be returned with the revised plans to facilitate continued staff review. If you or the applicant have any questions, please contact me at 760/602-2400, extension 1420. evelopment Services M evelopment Services Attachment Cc: Senior Civil Engineer - Engineering/Development Services Administrative Permit - 2nd Dwelling Unit Administrative Variance Coastal Development Permit Conditione1 Use Permit Condominium Permit Environmental impact Assessment General Plan Amendment Hillside Development Permit Local Coanai Plan Amendmenr Master Plan Non-ResideMia! PIanned Development manned Development Permit (FOR DEPARTMENT 0 0 D U 0 Precise Devefo Site Development Plan Special Use Permit Specific Plan e- Obrain from Engineering Depamnt , Tentative Tract Map Variance Zone Change List other applications not -- I specified 1 J 205- ~JS-& 2) ASSESSOR PARCEL NOW.: 3) PROJECT NAME: ’4) BRIEF DESCRIPTION OF PRQJE ATlVE OF THE 7) BRIEF LEGAL DESCRIPTION A/& 5 vi&,;t-&?38”T /A; hfr ufgT /w- ax/ 47yy U NOTE: A PROPOSED PROJECT REWIRING ONLY ONE APPLICATION BE RLED. MUST BE SIIBMrlTl!O PRIOR TO 4:OO P.M. A PROPOSED PROJECT REQUIRJNB MULTIPLE APPUCAflONS BE HLED, MUST BE SUBMl7TED PRlOR TO 3:30 P.M. PAGE 1 OF 2 Forin 16 CITY OF CARLSBAD REVIEW AND COMMENT MEMO # DATE: September 27, 2001 REVISED PLANS u REQUEST FOR REVIEW AND COMMENT ON APPLICATION NO. CUP 00-17 (B) NOTE: Please use this number on all correspondence. TO: t * * * * * * * * * ENGINEERING DEPARTMENT POLICE DEPARTMENT -ATTN: J. SASWAY FIRE DEPARTMENT - MIKE SMITH BUILDING DEPARTMENT - PAT KELLEY RECREATION - MARK STEYAERT PUBLIC WORKS DEPARTMENT (STREETS) - HEIDI HEISTERMAN Carlsbad LANDSCAPE PLANCHECK CONSULTANT - LARRY BLACK Carlsbad SCHOOL DISTRICT NORTH COUNTY TRANSIT DISTRICT - PLANNING DEPARTMENT SEMPRA ENERGY - LAND MANAGEMENT WATER DISTRICT CALTRANS (send anything adjacent to 1-5) Always Send Exhibits FROM: Planning Department PROJECT TITLE: North Coast Christian Fellowship Staff Contracting Inc. APPLICANT: PROPOSAL: Two modular structures for classrooms Please review and submit written comments andlor conditions to 9 the Project Planner in the Planning Department at 1635 Faraday Avenue, by NOV. 12,2001 . (If you have “No Comments”, please so state.) If not received by the date indicated, it will be assumed that you have no comment and the proposal has your endorsement as submitted. If you have any questions, please contact Christer Westman at 602- 4614 . The request for conditions will follow at the appropriate time. Christer Westman THANK YOU COMMENTS: m/7G .A 7- z7-0 f PLANS ATTACHED FRM0020 06/01 1 1998 CALIFORNIA BUILDING CODE APPENDIX CHAPTER 29 TYPE OF BUILDING OR OCCUPANCY' Appendix Chapter 29 MINIMUM PLUMBING FIXTURES WATER CLOSETS5 LAVATORIES6 (flxtuma per person) BATHTUB OR SHOWER (fixtures per person) MALE FEMALE MALE FEMALE (flxtuma per person) SECTION 2905 - GENERAL number of fixtures are the minimum required as shown in Table A-29-A and are assumed to be based on 50 percent male and 50 percent female. The occupant load factors shall be as shown in Tab'e A-29-A. including provisions for accessibility in accordance with Chapter 11. Plumbing fixtures shall be provided for the type of building occu- pancy with the minimum numbers as shown in Table A-29-A. The EXCEPTION: Where circumstances dictate that a different ratio is needed, the adjustment shall be approved by the building official. For the occupancies listed below, use 30 square feet (2.78 mz) per occupant for the group A "onference rooms, dining rooms, drinking 1 : 1-25 1:l-25 :stablishments, exhibit rooms, 2:26-75 2:26-75 gymnasiums, lounges, stages and similar 3:76-125 3:76-125 uses including restaurants classified as 4 126-200 4: 126-200 &up B Occupancies 5:20 1-300 5 :201-300 6301-400 6301400 Over 400, add one fixture for each additional 200 males or 150 females. minimum number of plumbing fixtures. one for each water closet up to four; then one for each two additional water closets For the occupancies listed below, use 200 square feet (18.58 mZ) per occupant for the minimum number of plumbing fixtures. Assembly places- Auditoriums, convention halls, dance floors, lodge rooms, stadiums and casinos Group B Offices or public buildings 1:l-50 3:l-50 1:1-200 1:l-200 251-100 451-100 2:201-400 2:201-400 3:lOl-150 6:101-200 3~401-750 3401-750 4 151-300 8:201-400 Over 750, add one fixture for each Over 300 males, add one fixture for each additional 200, and over 400 females add one for each 125. additional 500 persons. 1:1-15 1:1-15 2~16-35 2:16-35 3:36-55 3:36-55 Over 55, add one for each 50 cersons. Worship places Principal assembly area Worship places Educational and activitv unit one per two water closets one per 150 one cer 125 one per 75 one mr 75 one per two water closets one mr two water closets Group E Schools-for staff use All schools Education Facilities other than Group E Others (colleges, universities, adult centers, etc.) one per 40 one per 30 Schools-for student use Day care one per 40 one per 40 1:l-20 1:l-20 221-50 221-50 Over 50, add one fixture for each additional 50 cersons. one per 40 one per 40 1:l-25 1:l-25 226-50 226-50 Over 50, add one fixture for each additional 50 wrsons. 1-397 APPENDIX CHAPTER 29 TYPE OF BUILDING OR OCCUPANCY4 For the occupancies listed below, use 2,000 Group F Workshop, foundries and similar establishments, and Group H Occupancies 1998 CALIFORNIA BUILDING CODE WATER CLOSETS5 LAVATORIES~ (flxtures per person) BATHTUB OR SHOWER (fixtures per person) MALE FEMALE MALE FEMALE (flxtures per perron) 1:I-lO 1:l-IO one for each two water closets one shower for each I5 2:ll-25 2:ll-25 persons exposed to excessive 3:26-50 3:26-50 heat or to skin contamination 451-75 45 1-75 with irritating materials 5:76-100 5:76-100 Over 100, add one fixture for each additional 300 persons. square feet (185.8 mZ) per occupant for the minimum number of plumbing fixtures. Hospitals Patient room Ward room Jails and reformatories Cell Exercise room Other institutions (on each occupied floor) Group I Hospital waiting rooms Hospital general use areas one per room one per room one per room one per eight patients one per IO patients one per cell one per cell one per exercise room one per exercise room one per 25 one per 25 one per 10 one per IO one per eight one per 20 patients one per room (usable by either sex) 1:1-15 1:1-15 2:16-35 3: 16-35 3:36-55 436-55 Over 55, add one fixture for each additional 40 persons. For the occupancies listed below, use 200 square feet (18.58 m2) per occupant for the Group M Retail or wholesale stores 1:l-50 1:1-50 2:51-100 2:51-100 3:101-400 3:lOl-200 4:201-300 5:301-400 Over 400, add one fixture for each additional 500 males and one for each 150 females. one per room one per each two water closets minimum number of plumbing fixtures. one for each two water closets Group R Dwelling units Hotel guest rooms Congregate residences For the occupancies listed below, use 5,000 Group S Warehouses NOTE: Occupant loads over 30 shall have one drinking fountain for each 150 occupants. *The figures shown are based on one fixture being the minimum required for the number of persons indicated or any fraction thereof. 2Drinking fountains shall not be installed in toilet rooms. 3When the design occupant load is less than 10 persons, a facility usable by either sex may be approved by the building official. 4Any category not mentioned specifically or about which there are any questions shall be classified by the building official and included in the category which it most 5Where urinals are provided, one water closet less than the number specified may be provided for each urinal installed, except the number of water closets in such 6Twenty-four inches (610 mm) of wash sink or 18 inches (457 mm) of a circular basin, when provided with water outlets for such space, shall be considered equiva- nearly resembles, based on the expected use of the plumbing facilities. cases shall not be reduced to less than one half of the minimum specified. lent to one lavatory. one per dwelling unit one per guest room one per 10 one per 8 one per 12 one per 12 one per eight Add one fixture for each additional 25 males and one for each additional 20 females. additional 15 females 20. 1:1-10 1:1-10 one per 40 occupants of each sex one shower for each 15 2:ll-25 2: 11-25 persons exposed to excessive 3:26-50 3:26-50 heat or to skin contamination 451-75 45 1-75 with poisonous, infectious or 5:76-100 576- 1 00 imtating materials Over 100, add one for each 300 males and females. one per dwelling unit one per guest room Over 12, add one fixture for each additional 20 males and one for each one per dwelling unit one per guest room For females, add one bathtub per 30. Over 150, add one per square feet (464.5 m2) per occupant for the minimum number of plumbing fixtures. 1-398