Loading...
HomeMy WebLinkAboutMCUP 07-05; Sprint Nextel SD03x0145; Conditional Use Permit (CUP)THE LATEST BJTKW OT THE AMERICAN INSTITUTE OT ARCHITECTS OOCUWENTuai tcxui CONDITIONS or THE CONTRACT FOR CONSTRUCTION- AREMCLUOEB * THESE SPEOOCATQNS AS F COMPLETELY REPRODUCED HEREIN. ORAJWR ARE «OI TO BE SCALED. MVTTEN OUEXSiONS TAKE PRECEDENCE. AND WS SET Of PLANS S NTENDEO TO 8t USED FOR OUCRAMMATB PURPOSES ONLY. t*USS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF 10BX SHALL MCLUOE FURMSHINC ALL MATERIALS, EOUPUEHT. LABOR, (6UMKX AND ANTTHNS ELSE DEEMED NECESSARY TO COUPLETE NSTAUATDISa OTSCRBED KEREN. PRO) TO THE SUBUSSlO* OF MS. THC CONTRACTORS PARTICIPATIHC SHALL VISn T« JOB SHE ANO rAMLMOtt THEMSELVES «T1H ALL CONOTDONS AFFECTMC WE PROPOSED PROJECT. «TTH THE CONSTRUCTION ANO CONTRACT DOCUMENTS. FOLD CONDITIONS AMD CONFWW THAT THE PROJECT MAT BE teawPLSKD AS SOWN PRIOR TO PROCCEQINC WITH CONSTRUCTION. SHOULD ANY ERRORS. OMBSCNS. OR DISCREPANCIES K FOUND. THE GENERAL CONTRACTORSHALL uuauEur Ncrrrr THE Jm TEUECOU PROJECT MANAGER AND THE ARCHTTECT M lOVmC. • THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL WCLUOE THE MORE COSTLY OR EXTDCVE WORK IN THE BO. UNLESS SPECFCALLY DIRECTEDOTHERWISE- f A DSCREPANCr EXISTS AND THE PROJECT MANAGER AND ARCHTECT All "CO KOTOTCD. THE CtNERAL CONTRACTOR SHALL BE MOO^^ BLE FO> Aa COSTS MCURRED TO REPAIR OR CORRECT AU.\ ma MSULT. ODNTRACTOR OR SUBCONTRACTOR SHOULD NEGLECT TOJOt PROPERLY K ACCORDANCE WTIH PLANS ANO OR FAJL TO PERFORM ANY APPLICABLE PROvlSOKS OfMB TELECOM PROJECT MANAGER ATTER THRCE DAYS WRITTENIERAL COKTRACTOK WAY MAKE GOOO SUCH OCrtOENaES COST FROM THE PAYMENT DUE THC GENERAL CONTRACTOR. THE cOtBAT COWTVCTCW SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLT DEMD W THE COKSTRuaiON DRAMNCS/CONTRACT DOCUMENTS. THE CEKDM. eanWCTOR SHALL SUPERVTSE AND DIRECT THE PROOECT HERON. THE CONTCACTCR SHALL BC SOULY RESPONSIBLE FDR All CONSTRUCTION UUAS. METHODS. TECHMOUES. SEQUENCES AND PROCEDURES AKO FOB OXHUUIHC ALL PORTIONS OF THE WORK UKDER THE CONTRACT. WORKUANSHP IHROUCHOUT SHALL BE OF THE BEST QUALITY OF THE TRADEWYOLVtD. «0 a«U. MEET OR EXCEED THE FOLLOWING MINIMUM REnTSTANDARDS FOR OUALTTY AND PROFESSIONAL CONSTRUCTION PRACTICE: NRCA lUnMAL ROOTING CONTRACTORS ASSOOAnoNOtVSE VITERKATIONAL CLK1W 10355 W. HICCENS ROAD. SUITE 000 KSQOMT. L 60018 P>O5> 2*8-9070 SWCKA aaa METAL ANO AIR axprncwNC CONTRACTORSHUIONAL ASSOCIATIONUSn LAFAYETTE CENTER DRIVE OWlLf, XA 22021-12OJ (70i> B03-1SSO ItLP NTERMTIONAL INSTITUTE TOR LATH AND PLASTER ttt TRANSFER ROADST. PAUL MN SSI14-t40S (612) 654-0206 AIM AOHESXE kUNUFACTURERS ASSOCWTIONWl WRTH MlCrtCAN AVWUE. SUHE 2400OXACC, IL 60611 (J12) 644-6S10 THE SENERAL COKntCTOR SHALL INSTALL AU EQUIPMENT ANO MATERIALS M SKOflC COVPLWCE «™ UANUFACTURER'SACNOOR'S SPECFCATIONS UNLESS NOTED OTKERMSC OR IVCRE LOCAL COOES OR ORDINANCES TAKE PRECEDENCE. VICINITY MAP ASSESSOR'S PARCEL NUMBER: 212-092-23 THE 1996 THOMAS GUIDE PAGE 1127 CJ 9 ALL WOS* PEKVnO ON PfiOOEa AKD MATERIALS INSTALLED SHALL BE W STRICT ACCORONCE WTH ALL APPUCABLE CODES. REGULATIONS, ANOORDNANCES WCLUDMB OSHA AND STATE SAFCTY ORDERS. THE GENERAL CONTRAOOR S«a WE All. VIOTCES «W) COMW.1 WITH AU. LAWS. ORDIHANCES. RULES. UCUUrOKS ANO LAMIA. ORDERS OF ANY PU8UC AUTHORITY. MUNICIPALANO UTUTY CCUPHfl SPEOFICATDNS. AND LOCAL ANO STATE JUfBSOICnONAL COOES 8EARK ON THE PERFORMANCE OF THE WORK. 10. THE CCNCRAL COMIIACTDR SHALL GUARANTEE THC WORK IN GENERAL FOR ONE YEAR AFTER TENANTS FINAL ACCEPTANCE OF THE WORK. II THE GENERAL OOKTOCTOR SHALL MMMN AT THE PROJECT SITE A. FU1 SEtor cotsTRucncK OOCUMENTS UPDATED WTH THE LATEST REVISIONS AND ADDENDA OR OWTtXTIONS FOR THE USE BY ALL PERSONNEL INVOLVED WTH THE PROJECT. M. QCtAILS WajJOffi KRE3N ARE MtCXOEO TO SHOW END RESULT Of OESRK.UNOR uoorcuioc MAY BE REQUIRED TO sun JOB coNomoNS oft STtUATOC. SUCH KOdFCATWS SHALL BE INCLUDED AS PART OF THC SCOPE OF «OK MB SHALL BC CLEARLY MQTED ON AS-BUILT ORAmtGSOEUVOSD TDM lOECOM H COUPLEnON OF CONSTRUCTION. IX THE STRUCTURE OHIPONEKTS OF 7H5 PRQJta SITE AND FACILITY ARE NOT TO BE ALTERED UNLESS K>in> OTHERWISC. M. EUCTRKAL SlSTOI SHAa BE GROUNDED PER NEC ARTICLES 290 AND BIO. IS. ALL NEW OPEKM2 H TIC EXTERIOR ENVELOPE SUCH AS AT WALL AND ROOT PWETRATBNS SHALL BC CAULKED OR StALBD TO U«T INFITRATIOM OF AM»KO KQSTURt. 10. SEAL AU PDCTMtNS TMROUCH FRE-RATED AREAS WITH U.L LISTED OR FIRE UARSKALL APPMtfD UATERULS IF AND KXERt APPIJCABLE TO THE FACtrTY AND PROJECT SITE. 17; P«OV»£ A IWABOI FTRE EJfflMCUISHER WTH A RATWC OF NOT LESS THAW 2-AOR l-AIOBC «H» » FOI TRAVEL OSIAHCE TO AU. PORTIONS OT THE PSDJECTMCA oaac easnacnm. IK THE COCXAL OOtmCTOIt SHALL HAKE NECESSARY PR<X1S<0«S TO PROTECT EtKTMC.KpRovoens, SUM AS LAUJSCAPK. PAVMG. OXSMG. ETC ouao CONSTRUCTION.UPON COmCTIM OT WORK. CONTRACTOR SHAU RCPAJR ANY OAMACE THAT UAY HAVE OCOLBRtt OUC TO CONSTRUCTION ON OR AaOUT THE PROPeRTY. tO. IKE COOAL OXTWTOR SHALL XT ALL TWO MAINTAIN IKE WORK AREA CLEAN ANOHAZAROfWZ CUOC COWTRUCnON AMD SHALL OSfOSC. OF ALL OKI. DtBaB. RUBBBH AND «OOe COXMUT NOT SPtCKD AS RBMNMB ON THE PMPOm. PMKBB SHAU K LOT M CLEAN COMDinON ANO FBJZ FROM MMTSPOTS, DUST, otauwes or ANY NATURE. 5858 EDISON PLACE CARLSBAD. CA 92008 GENERAL SPECIFICATIONS (CONTD) 20. THE ARCHITECTS AMD ENGINEERS HAVE UADE EVERY ETFORT TO SH FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COKPLETE SCOPE OF WORK. CONTRACTORS BOOKS THE JOB ARE NEVERTHOESS CAUTIONED THAT UMOR OUSSIONS OR ERRORS H THE DRA41NCS AND OR SPEaFCAIBNS SHALL NOT EXCUSE SAO CONTRACTOR FTMU COMPLEnNC THE PROJECT ANO IMPROVEMENTS M ACCORDANCE WITH THE NTENT Of THESE DOCUMENTS. 21. THE CENESAL CONTRACTOR KUST PERFORM WORK OW"? OWNER'S PREFERREDHOURS TO AVDO OtSTURBWS NfiRUAL BUSINESS TENANTS. PROJECT SUMMARY INSTAUATtON OF A BASE TRANSCEIVER STATION (BTS) LOCATED ON GRADE ON THE SOUTH SIDE OF AN EXISTING BUILDING INSTALLATION OF ANTENNA ARRAYS ON SOUTH,WEST ANO EAST ELEVATIONS OF THE EXISTING BUILDING. 3 ARRAYS/3 ANTENNAS PER ARRAY/9 TOTAL ANTENNAS SHALL BE WALL MOUNTED INSTALLATION OF TWO 4" GPS ANTENNAS COAXIAL CABLE RUNS FROM BTS TO ANTENNAS A NEW TELEPHONE SERVICE RUN TO BTS A NEW 100A ELECTRICAL SERVICE TO BTS NEW MANUAL TRANSFER SWITCH AND GENERATOR PLUG FOR EMERGENCY POWER BTS AREA IS APPROXIMATELY 168 SQUARE FEET SHEET INDEX COr-TACTS gtt cnuuiumcnoHS PCS. 16200 VW KARMAN (RVME.CA BW1J TEL (714) 6W-3000 NOT APPLICABLE TO THIS PROJECT __ I COMMUMCTICHS PCS.. L.P.IS200 VON KAMAN 10. (714) WJ-5000 m renuuuNCATONS |JNB ratcoM, INU Mfi SECOND STREET. SUITE ft EMQMTAS. CA B2024(7W) 7SJ-OM7 ttttMKCt: BOOTH * SUAREZ AKCHTlrCTURC PLMINMGPA BOX 4651 CAftLSSAO. CA MOOB (780) 4J4-M74 SID SAM MARCOS BLVD.. SUITE 201 SAM UARCO3. CA. »2O89 (61») 744-221S SALEM * SALCH W A STREET HOtSAN oeco. CA. 93101 TIME OORPORATION 5698 EOEON PLACECARLSBAD. CA 62OOB T-1 TFTLE SHEET A-1 SITE PLAN A-2 ENLARGED SfTE PLAN A-3 ROOF PLAN A-4 NORTH 4 £>ST ELEVATIONS A-5 SOUTH & WEST ELEVATIONS A-6 DETAILS S-I ROOF FRAMING PLAN &EQUIPMENT BOLT HOLE CONFIGURATION S-2 DETAILS E-1 ELECTRICAL. NOTES & SYMBOLS E-2 LmUTY SERVICE RUNS & POWER PLAN E-3 POWER SINGLE LINE DIAGRAM & ELECTRICAL DETAILS E-4 GROUNDING DIAGRAMS E-5 GTOUNDINC OETAILS 9/10/97 DRAWN BY: RJR CHECKED BY: WB REVISIONS CATC IWTVM. BUILDING DATA OCCUPANCY COSTM: BULDMC: OCCUPANCY PROPOSED PROJECT: TTPt OF CONSTRUCTDM (OOSTMC): AREA WOPOfKO STORKS (EXSTTNC): B * Ft 8 V-M. $P*MCl£t<EO 2«0 SF ONE APPLICABLE CODES AU. WORK SHAU. COMHY WITH THE FOLLOWING APPUCABUT COOES BUCDWC OOOC TITLE 24 CODE. 1M4 EDOIOH fMTONAt OtCTTOCAL COOC 1MJ OXTlON APPROVAL SIGN OFF OF WORKING DRAWINGSPATE SOUTH PALOMAR 58M DJSON PLACE CARLSGAD. CA 92006 JOB# SO145 TITLE SHEET CASE NUMBER T-1 SWALE SECTION A SOLE: t'-10'-0M PROPOSED COX COMMUNICATIONS ANTENNA ARRAYS. TOTAL OF 3 ARRMS/3 ANTENNAS PER ARRAY EXISTING 10-O* SEWEREASEMENT aow PROPOSED COX COMMUNICATIONS EQUIPMENT CABNETS (BTS) AT GRADE LEVEL SEE SHEET A-2 EXISTING SEWER EASUENT EXISTING DRAINAGE PATTERN. DRAINAGE PATTERN AND ALIGNMENT SHALL NOT BE CHANGED. A CONCRETE- Wttl DC ADDED OH PC BAKE- «.or SITE PLAN PROJECT DESCRIPTION INSTALLATION OF A BASE TRANSCEVER STATION (BTS)LOCATED ON GRADE ON THE SOUTH SOX. OF AN EXETINC BUOJDINC IHSTAUATION OF ANTENNA. ARRAYS ON SOUTH. WEST AND EAST ELEVATIONS OF THE EXISTING BUILDING. 3 ARRAYS/3 ANTENNAS PER ARRAY/8 TOTAL ANTENNAS SHALL BE WALL MOUNTED INSTALLATION OF TWO 4* GPS ANTENNAS COAXIAL CABLE RUNS FROM BTS TO ANTENNAS A NEW TELEPHONE SERVICE RUN TO BTS A NEW 100A ELECTRICAL SERVICE TO BTS NEW MANUAL TRANSFER SWITCH AND GENERATOR PLUG FOR EMERGENCY POWER BTS AREA S APPROXIMATELY 1«S SQUARE FEET LEGAL DESCRIPTION PARCEL 2 OF PARCEL MAP NO. 16687. IN THE CITY OF CARLSBAD. COUNTY OF SAN DIEGO. STATE OF CALIFORNIA. FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY. ON MAY 30. 1989 ASRLE/PAGE NO. 89-283195 OF OFFICIAL RECORDS. PROJECT STATISTICS SITE AREA: AREA OF EXISTING BUILDING: ZONING: 85.408.0 SF - 2.0 ACRES/ 10,5*8.0 SF PW PLANKED BUILDING DATA OCCUPANCY EXISTING BUILDING: OCCUPANCY PROPOSED PROJECT: TYPE OF CONSTRUCTION (EXISTING): AREA PROPOSED PROJECT: STORIES (DOSTNC): B ft n 8 V-N. SPRNKLERED 168 SF ONE 9/10/97 DRAWN BY: RJR CHECKED BT: WB REMSIONS DATE OESOaPTION SOUTH PALOMAR sasa EOSON PUCE CARLSBAD, CA 92000 OB# SD145 SITE PLW CASE NUMBER A-1 v-o- TOP OF SLOPE KEYED NOTES:CONSTRUCTION PLAN <& SMOOTH STUCCO FINISH ON r-0" HIGH ^ SCREEN WALL. SEE ELEVATIONS FOR REGLETS <& NEW «'-6' HIGH CHABttttK GATES WOK SCREEMHC ^ SLATS. DROP-PtNS AND PADLOCK HARDWARE. GATES AND SLATS SHALL BE PAINTED TO MATCH EXISTING BUILDING <S> CONCRETE SLAB WITH 6* HIGH CURB AT BIS EDUPKEHT. ^ WASP 1/8* PER FOOT TOWARDS OWE ft OMNMX SW1£ ^O ANTENNA CABLE COVER ASSEMBLY PRIMARY BASE TRANSCEIVER STATION(BTS) LOCATION EXPANSION CABINET PRIMARY POWER CABINET BATTERY CABINET AUXILIARY CABINET COAXW. CABLE TRAY \2' STEP OOWN TO CONCRETE WALK EXISTING CURB O LOADING DOCK WORK LIGHT 3-1/2' THICK CONCRETE WALK EXTENDED TOEDGE OF PARKING. PROVIDE 2x4 REDWOODSLEEPERS O 4'-0' O.C. GPS ANTENNA EXISTING BUILDING EXISTING PRIVATE SEWER EASEMENT CENTERUNE OF EXISTING EARTH DRAINSWALE TO REMAIN APPROXIMATE LOCATION OF EXBTINGBELOW GRADE EXBTING ROOF DRAIN OUTLETS TO MANUAL TRANSFER SWITCH REVERSE SERVICE GENERATOR RECEPTACLE ELECTRICAL DISCONNECT CONDUIT TO REVERSE SERVICEGENERATOR RECEPTACLE 8* STEEL PIPE STANDARD FOR GATE 9/10/97 DRAWN BY: RJR CHECKED BT: WB REVISIONS OATC OCSCRFTON SOUTH PALOMAR sasa EOGON PUCE CARLSSAD. CA 92006 JOB# SD145 ENLARGED SITE PLAN CASE NUMBER ENLARGED SITE PUN A-2 EXISTING ROOF HATCH (TYPICAL) PROPOSED COX COMMUNICATIONS ANTENNA ARRAYS. TOTAL OF (3 ARRAYS/3 ANTENNAS PER ARRAY/ 9 ANTENNAS TOTAL) ANTENNAS ARE 4'-3- HIGH AND SHALL BE PAINTED TO MATCH ADJACENT WALL SURFACES LINE OF EXTERIOR WALL (TYPICAL) EXISTING SKYUTES (TYPICAL) SECTOR 3 2W EXISTING ROOF VENTILATOR (TYPICAL) PROPOSED COX COMMUNICATIONS GPS ANTENNA PROPOSED COX COMMUNICATIONS COAXIAL CABLE TRAY ANCHORED TO PARAPET F SECTOR 2 1251 ANTENNA AND COAXIAL CABLE SCHEDULE SECTOR 1 2 3 DR. N.E- S£. WEST COAX. CABLE LENGTH(+ / - s1) 116' 140' 183* JUMPER LENGTH (* / - 30 8' 8* 8' AZIMUTH 43T 12S- 289 COAX SIZE 7/B- 1-1/4* 1-5/8" PROPOSED COX COMMUNICATIONS EQUIPMENT CABINETS (BTS) AT GRADE •FIELD VERffY ALL CABLE LENGTHS PRIOR TO ORDERtNO CABLE SECTOR 1 45" PROPOSED CABLE TRAT OVER PARAPET 9/10/97 DRAWN BY: RJR CHECKED BY: W8 REVISIONS DATE DESCRIPTION MTIAL 50UTH PALOMAR S6SB EDISON PIACC CARLSBAD. CA 92006 OB# S0145 ROOF PLAN CASE NUMBER ROOF PLAN SCALE A-3 EXISTING TU.T-UP CONCRETE BUILDING WITH CAST IN DECORATIVE GROOVES (TYPICAL) PROPOSED COX COMMUNICATIONS ANTENNAS UOUNTEO TO HALL (3 ARRAYS OF J ANTENNAS EACH / ANTENNAS ON THS ELEVATION ARE 4'-3* TALL) PAINT ANTENNAS AND BRACKETS TO MATCH WAUL (TYPICAL) TOP OF PARAPET O-2P---8 —^ TOP OF PARAPET OF ANTENNA OF CONCRETE WING OF PARAPET NORTH ELEVATION PROPOSED COX COMMUNICATIONS ANTENNAS MOUNTED TO WALL (3 ARRAYS OF 3 ANTENNAS EACH / ANTENNAS ON THIS ELEVATION ARE 4'-3~ TALL) PAINT ANTENNAS AND BRACKETS TO MATCH WALL (TYPICAL) r-o* r-or EXISTING LOADING DOCK AREA OF PARAPET \rft'-. PROPOSED COX COMMUNICATIONS •errs EQUIPMENT BEHIND CONCRETE BLOCK SCREEN WALL. WALL SHALL BE FWBHED WTH SMOOTH STUCCO AND TRrREGLET REVEALS TO CONTINUEBUUNMO'IRU PATTERN AS SHOWN. j PHUT PANELS. COMPATIBLE WITH SCHEME EAST ELEVATION NOTEi ELEVATIONS NOTED («) ARE SHOWN ABOVE LOWEST ADJACENT COSTING GRADE ACCOROMG TO TOPOGRAPHIC MAP DATED 11/12/86 PROVIDED TO BOOTH Sc SUAREZ BY JU CONSULTtNO GROUP ANDCAIVADA SURVEYING 9/10/97 DRAWN BY: RJR CHECKED BY: WB o«E DescHPnoN mwi SOUTH PALOMAR 5858 EDISON PtACC CARLSBAD. CA 92008 OB# SD145 _ . . , . NORTH AND EAST ELEVATIONS CASE NUMBER NORTH AND EAST ELEVATIONS SCALEr-20'A-4 •-*!. EXISTING TILT-UP CONCRETE BUILDING WITH CAST IN DECORATIVE GROOVES (TYPICAL) TOP OF PARAPETO— --^ 25*-6' TOP OF CONCRETE WING TOP OF PARAPET 9" PROPOSED COX COMMUNICATIONS ANTENNAS MOUNTED TO WALL (3 ARRAYS OF 3 ANTENNAS EACH / ANTENNAS ON THIS ELEVATION ARE 4'~f TALL) PAINT ANTENNAS AND BRACKETS TO HATCH WALL (TYPICAL)PROPOSED COX COMMUNICATIONS OPS ANTENNA. PAINT TO WATCH EXISTING ADJACENT SURFACES. - PROPOSED COX COMMUNICATIONS COAXIAL CABLE TRAY UP WALL * OVER PARAPET PAINT TRAY TO MATCH COSTING COLOR SCHEME SOUTH ELEVATION PROPOSED COX COMMUNICATIONS ANTENNAS MOUNTED TO WAUL (3 ARRAYS OF 3 ANTENNAS EACH / ANTENNAS ON THIS ELEVATION ARE 4'-3* TALL) PAINT ANTENNAS AND BRACKETS TO MATCH WALL CTTPICAL) PROPOSED COX COMMUNICATIONS BTS ENCLOSURE WITH 6f-6" HIGH CHAIKUNK GATES WITH SCREENING SLATS. DROP-PINS AND PADLOCK HARDWARE. GATES SHALL BE PAINTED TO MATCH EXISTING BUILDING COLOR SCHEME TOP OF CONCRETE _ _ TOP OF PARAPET O 1C - - —9 TOP OF PARAPET PROPOSED COX COMMUHCATONS BTS EQUIPMENT BEHIND CONCRETE BLOCK SCREEN WALL WALL SHALL BE FINISHED WITH SMOOTH STUCCO AND TRY* REGLET REVEALS TO CONTINUE BUILDING TRIM PATTERN AS SHOWN. PAINT PANELS COMPATIBLE WITH BUILDING COLOR SCHEME WEST ELEVATION NOTE: ELEVATIONS NOTED («) ARE SHOWN ABOVE LOWEST ADJACENT EXISTING GRADE ACCORDING TO TOPOGRAPHIC MAP DATED 11/12/96 PROVIDED TO BOOTH & SUAREZ BY JM CONSULTING GROUP AND CALVADA SURVEYING 9/10/97 DRAWN B1: RJR CHECKED BY: W8 . REVISIONS DATE OESCRFnON WTW. SOUTH PALOMAR sasa QXSON PLACE CARLSBAD. CA 92006 JOB# SDU5 SOUTH AND WEST ELEVATIONS CASE NUMBER SOUTH AND WEST ELEVATIONS SCALE A-5 DOWN TILT WHERE REQUIRED PCS SECTOR ANTENNAATTACH TO PIPE MOUNT WITH SUPPLIED ANTENNA HARDWARE STANDARD ANTENNA PIPE MOUNT CABLE TRAYSEE PLAN_AND DETAIL CORE r« MAX. HOLE FOR CABLE. SEAL AS REQUIRED 1/2"» COAX JUMPER PROVIDE MINIMUM 5" BEND RADIUS L 3 x 3 x 1/4 MOUNTS SEE APPLICATION DETAIL FOR ANCHORAGE EXISTING CONCRETE STRUCTURE NOTE:INSTALLATION OF COAXIAL CABLE AND ANTENNAS BY OTHERS PIPE MOUNT SHALL I BE INSTALLED PLUMB 3/8" THICK PLATEWITH 11/18"« HOLES 2V SCHEDULE 40 (Z-3/8V 0.0.) x 48' LONG PIPE MOUNT ENTIRE UOUNl SHALL BE HOT-DIP GALVANIZED 11/16'* HOLES 4*nt I y x r K 1/4' STEEL V 1-1/2 5/8'* HLTI KWK BOLT II ANCHORS (ICBO |4827) TYPCAL NO SPECIAL INSPECTION REOUREO 1-1/2' PIPE MOUNT SCALE . •»1-1/2'-V-0" -5 5/8** HLTI KWtK BOLT I ANCHORS (K80 fW27) TYPICAL NO SPECW. INSPECTION REQUIRED 2-3/4'EMBED r- B-UNE {OR EQUAL) SERIES V^ \ 248 HOT WP GALV f HIGH / \ \ STER CABLE TRAY WITH ' | \COVER EXSTWC CONCRETE WALL / PARAPET COAXIAL ANTENNA CABLE UNISTRUT P1000 O 4'-0' O.C. SET IN URETHANE CAULKING THE INfOROMlON CONTAINO) H THIS SET OFCONSTRUCTION DOCUMENTS IS PSOPRIETART BT NATURE ANT USE OS OSCLOSURt OTHER TMHN TVV.T WCM ROMC TO COS COyWUSCkTOC, PCS. U>. IS STRCTLY PROHIBITED. 3" K 3" STEEL V MOUNT 1t/1«*« HOLES 3/8** HLTI KWtK BOLT II ANCHORS (ICBO #4627) TYPICAL. NO SPECIALMSPECnON REQUIRED SET ENTIRE PLATE IN URETHANE CAULKING EXISTING CONCRETEWALL S25 PIPE MOUNT SCALE 3"-1*-0* PAINT TO MATCH ADJACENT WALL SURFACE •NELSON* CMP FRESTOP COMPOUND (UL *1479) EMT CONDUIT EXISTING CONCRETEWALL CORE HOLE 9/10/97 DRAWN BY: RJR CHEEKED BY: WB REVISIONS OWE DESCRIPTION WT1H. ANTENNA DETAIL 3/4^-0-STANDARD ANTENNA PIPE MOUNT 1-1 VERTICAL CABLE TRAY SUPPORT SCALEr-r-o*CONDUIT SEALANT SCALEN.T^. Jf=- (2)1/2"« MOLLY BOLTS PER SECTION AT STUD WALLS (2) 1/2"» HILTI KWIK BOLTS D ANCHORS (ICBO J4«27). NO SPECIAL INSPECTION REQUIRED AT CONCRETE WALLS PROPOSED POWER. TELCO * GROUNDING CONDUCT WITH { )» WPE CLAMPS TO UNISTRUT , ^~*J ASSEMBLY. PAINT TO MATCH ADJACENT WALL SURFACE LONG UNISTRUT P1000 Oo.c. EXISTING WALL EXISTING WOOO- FRAUED ROOF 4 « 4 SUB-PURLINS 3/8'< LAC SCREWS V \- 2-1/4* EMBED O HLTI ANCHORS O CONCRETE WALLS NEW 12' LONG UNISTRUT PI 000 CONDUIT wrm CLAMPS #8 SELF TAPPING SHEET METAL SCREWS O 6* O.C. COAXIAL ANTENNA CABLE B-UNE (OR EQUAL) SERIES 248 HOT DIP GALVANIZED 4" HIGH STEEL CABLE TRAY WITH COVER 4' SQUARE PVC. W RATED. SLEEPER O 4'-0' O.C. (VERIFY) EXISTING ROOFING- TO REMAIN DPI CAO£ TRAY MOTH 44* SOUTH PALOMAR 8838 EOSON PUCE CARLSBAD. CA 02006 JOB# SD145 DETAILS CASE NUMBER SCALE ANCHOR BOLTS (TYPICAL)T a'-c:8' 3-1/21 r—5-1/7' WCH RAISED \ CONCRETE CURB =r~rr—— 'i _±-L_ MANUAL. iwuu-ME BY OTHERS. INSTALLATION CONTRACTOR SHALL VERffY BOLT LAYOUT WITH JN8 TELECOM. WC. PROJECT MANAGER PRIOR TO INSTALLATION. ALL ANCHOR BOLTS SHALL B£ "WUTI KWIK-BOLT II 1/2* DIAMETER WITH MINIMUM J-1/4 EMBEDMENT. 1.08.0. f«27 NO SPECIAL INSPECTION REQUIRED EQUIPMENT KEY ^4-3/4- EQUIPMENT CABINETS ABOVE SHOWN DASHED AUXILIARY CABINET BATTERY CABINET PRIMARY POWER CABINET PRUARY BTS UNIT EXPANSION CABINET CABLE COVER EQUIPMENT BOLT HOLE CONFIGURATION SCALE fl'-2 1/2 6' THICK CONCRETE SLAB WITH #4 REBAft O 16" 0X5. EACH WAY CENTERED IN SLAB OVER 4* THICK CLEAN SAND FILL OVER COMPACTEDEARTH OUTLINE OF EXISTING ADJACENT BUILDING 5-1/2* HIGH CONCRETE CURB FOR EQUIPMENT SLOPE SLABlomau CTYPBAU OUTLINE Of BTSEQUIPMENT ABOVE 8P THICK CONCRETE BLOCK WALL CONCRETE WALK SEE SHEET A-2 ^C FOUNDATION PLAN GENERAL NOTES 1. THE CONTRACTOR SHALL EXAMINE THE STRUCTURAL DRAWINGS AND SHALL NOTIFY THE JNB TELECOM. INC. PROJECT MANAGER AND THE ARCHITECT IN WRITING SHOULD ANY DISCREPANCIES BE FOUND PRIOR TO PROCEEWNC WITH WORK. 2. THE DRAWINGS AND SPECIFICATIONS REPRESENT THE COMPLETED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES AND MEANS NECESSARY TO PROTECT PERSONS AND THE EXISTING STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE BUT NOT BE LIMITED TO. BRACING, SHORING. ETC. VISITS BY THE ARCHITECT SHALL NOT INCLUDE INSPECTION OF THESE ITEMS. 3. ALL WORK NOT DETAILED OR NOTED SHALL BE CONSTRUCTED IN ACCORDANCE WITH OTHER SIMILAR WORK AND TYPICAL DETAILS SHOWN ON THE DRAWINGS, DIMENSIONS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. NO PIPES OR DUCTS SHALL BE PLACED IN SLABS OR WALLS UNLESS SPCCtnCALLY OETA/LED OR APPROVED BY THE ARCHITECT. 4. ALL WORK PERFORMED ON PROJECT AND MATERIALS MSTAUJED SHALL BE N STRICT ACCORDANCE WITH ALL APPUCABUI CODES. REGULATIONS. ANDORDINANCES MCLUDMC OSHA AND STATE SAFETY ORDERS. THE GENERAL CONTRACTOR SHALL OVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES,RULES. REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, KUMOPALAND unjrr COMPANY specmcxnoNs, AKO LOCAL AND STATE JURSOCTKIKALCODES BOOHS ON THE PERFORMANCE OF THE WORK. FOUNDATION NOTES & SPECIFICATIONS 1. THIS SHE REOURES PREPARATION THAT NCLUDES BUT IS NOT LOOTED TO REMOVAL OF LOOSE SURFIOAL SOILS AND OTHER DELETERIOUS MATERIAL TO A DEPTH OF IB* BEIOW THE PROPOSED SLAB. 2. ALLOWABLE SOLS BEARING VALUE 1000 PSF. EXPANSION INDEX UNKNOWN 3. PRIOR TO THE CONTRACTOR REQUESTING A BUILDING DEPARTMENT FOUNDATION INSPECTION, THE SOLS ENGINEER SHALL ADVISE THE BULDMC OFFeiAL IN WRTTWC THAT: A. THE EQUFUENT PAD WAS PREPARED M ACCORDANCE: WITH CITY OF CARLSBAD STANDARDS. B. THE UnUTY TRENOCS HAVE BEEN PROPERLY BACKFILLED AND COUP; C. THE FOUNDATION EXCAVATION. FORUNG AND REINFORCEMENT COMPLYAPPROVED PLAN 4. THE CONTRACTOR 9MU. COOROWTE THE UXXTO6 OF ALL UEO ITEMS WTK THE EDUFUEHT AKO ELECTRICAL RAKS AND SHALL VEHPf IDCAIOH OF AW IMXRSLAB COMMIT POOR TO POURPK CONCRETE AND StWL NOTPT THE JKB TOOMM PROJECT UMAGER M WRITING F 5. RE8W REMORCEKENT M SLAB9MLL BE SUPPORTED ON CHARS AT 24* OC. EACH WAY TO WSURE RSNFORCOOir S CENTERED M SLAB. 8. FOOTM aosHsms SHOW CM THE OEMS ARE MMM* AND KUST BE MOEASEO AMD/ORSTEPPED BY THE CONTRACTOR ««RE REQUBSD 8Y SPEOFC FOB COOmONS AND AS REQURtD BY THE SOLS BCMEEft. THE COXIRACT08 SHALL NCdlFr ARCHTECT N VRITMG WEN AND «HBI SUCH H3SASES OCCUR, 7. SLOPE FMSHED GRADE AWT FROM ALL FOOTMCS. SUBS AM) OTHER STRUCTURES UNULM f t4 FNE FEET 8. CURB SURFXZ SHU. BE LEVEL. APRON «OW AfiEA SHMI SLOPE UNUUU 1% DOWN AKDAWar FROK EOUPUEKT CURB 9. ALL COKOlir STUB8ED THROUGH FW> (EXCEPT TELCO GHXM>> SHALL GE FLUSH WIN SURFACE OF PAD. MATERIAL SPECIFICATIONS CONCRETE: 2000 PS! OR BETTER REN^ORCWC BAft GRADE 40 OR BETTER 9/10/97 DRAWN BY: RJR ' CHECXEO fff: W8 REVISIONS DATE OESCftPTION NTIUL SOUTH PALOMAR S8S8 EDISON PUCE CARLSBAD, CA 92006 OB# SD145 TOUNDATION PLAN & EQUIPMENT FRAME CASE NUMBER S-1 COX COMMUNICATION (OTS) EQUIPMENT ABOVE SHOWN DASHED J-1/2' THICK CONCRETEWUX SEE SHEET A-2 UNE OF EXISTING BUILDING .EQUIPMENT CURB -EXtSTlNG GRADE 6* THICK CONCRETE SLAB WITH f 4 REBAR O 16* O.C. EACH WAY CENTERED SLAB OVER 4* THCK CLEAN SAND flL OVER COUPMCTED EARTH COMPACTED EARTH WALL SHALL BE FINISHED WITH SMOOTH STUCCO AND TRY* RECLET REVEALS TO CONTINUE BUUMNG TRIM PATTERN AS SHOWN. PANT PANELS COMPATIBLE WITH BUUMNG COLOR SCHEME 6- x 8* x 16' CONCRETE BLOCK GROUTED O STEEL CELLS ONLY O 24* O.C. HORC. «5 O 16' O.C. VERTICAL STAGGERED f5 O 16* O.C. VERTICAL DOWELS STAGGERED . DOWELS WITH 8' LEGS O 24' O.C. r\j -NEW 12" DEEP \^ CONTINUOUS / CONCRETE FOOTING/ /WTTH (3) #4 CONTINUOUS . BLOCK WALL SCALE1/2'-r-o' 8*« GALVANIZED STANDARD STEEL PIPE COLUMN FINISH GRADE VERTICAL WITH 13 TTES O 12' 9/10/97 DRAWN BT: RJR CHEEKED BY: WB REVISIONS DATE DESCWTKW mm. SOUTH PALOMAR S8S8 EDISON PLACE JWLS8AD. CA 92008 OB# SD145 STKUCTURAL DEJAILS CASE NUMBER EQUIPMENT SECTION BLOCK WALL S-2 V«TV- ^&. CODE. CHAPTER Zi AND GUIDELINE FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS AND PLUMBING PIPING SYSTEMS'. PUBLISHED BT SMACNA AND PPIC. OR THE SUPERSTRUT-SEISMIC - OR.-THE KIN-LINE SEISMIC RESTRAINT SYSTEM. 2. ALL ELECTRICAL IWTERIALS AND EQUIPMENT SHALL BE NEW AND SHALL BE LISTED BY UNDERWRITER'S LABORATORIES (UL) AND SEAR THEIR LABEL OR LSTEO AND CERTIFIED BY A NATIONALLY RECOGNIZED TESTING AUTHORITY WHERE UL DOES NOT HAVE A LISTING. CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTUREER ATTESTING TO ITS SAFETY. IN ADDITION. THE MATERIALS. EQUIPMENT, AND INSTALLATION SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING CODES AND REGULATIONS: AMERICAN SOCEIY OF TESTING MATERIALS (ASTM) INSULATED POWER CABEL ENGINEERS ASSOCIATION (IPCEA) NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) AMERICAN STANDARD ASSOCIATION (ASA) NATIONAL FIRE PROTECTION AGENCY (NFPA) AMERICAN NATIONAL STANDARD INSTITUTE (ANSI) NATIONAL ELECTRICAL CODE (NEC) CALIFORNIA CODE OF REGULATIONS TITLE 24 (CCR) /NST/7VTE OF ELECTRICAL AND ELECTRONIC ENGINEERS (IEEE) ALL LOCAL COOES HAVING JURISDICTION WHERE THE COOES HAVE DIFFERENT LEVELS OF REQUIREMENTS. . THE MOST STRINGENT CODE SHALL APPLY. 3 THE CONTRACTOR SHALL VISIT THE SITE INCLUDING ALL AREAS INDICATED ON THE DRAWINGS. HE SHALL THOROUGHLY FAMILIARIZE HIMSELF MTH THE EXISTING CONDITIONS AS WELL AS THE ELECTRICAL AND GROUNDING REQUIREMENTS OF THIS PROJECT AND BY SUBMITTING A BIO, ACCEPTS THE CONDfTIONS UNDER WHICH HE SHALL BE REQUIRED TO PERFORM HIS WORK. 4. fT SHALL BE THE CONTRACTORS RESPONSIBLE TO OBTAIN A COMPLETE SET OF CONTRACT DOCUMENTS. ADDENDA. DRAWINGS AND SPECIFICATIONS AS WELL AS THE LATEST EDITIONS OF THE COX/SPRINT PCS SfTE DESIGN SPECIFICATIONS MANUAL AND THE BTS tELCO INTERCONNECT CONDUIT REQUIREMENTS. HE SHALL CHECK THE DRAWINGS OF THE OTHER TRADES •ANB SHAH. CAREFULLY READ THE ENTIRE SPECIFICATIONS AND DETERMINE HIS RESPONSIBILITIES. FAILURE TO 00 SO SHALL NOT RELEASE THE CONTRACTOR FROM DOING THE WORK IN COMPLETE ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS. 5. THE CONTRACTOR SHALL COORDINATE HIS WORK WTTH OTHER TRADES AT THE SITE. ANY COSTS TO INSTALL WORK TO ACCOMPLISH SAID COORDINATION «HCK DIFFERS FROM THE WORK AS SHOWN ON THE DRAWINGS. SHALL, BE. INCURRED- BY THE - CONTRACTOR. ANY DISCREPANCIES.- AHBCUIT1ES OR CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE JNB TELECOM PROJECT MANAGER AND THE ARCHITECT IN WRITING PRIOR TO SUMBITTINC A BIO. ANY SUCH CONFLICTS NOT CLARIFIED PRIOR TO BID SHALL BE SUBJECT TO THE INTERPRETATION OF THE ARCWTECT AT NO ADDITIONAL COST TO THE OWNER. 5. THE CONTRACTOR SHHL OBTAIN AND KEEP UP-TO-DATE A COMPLETE RECORD SET OF DRAWINGS. UPON COMPLETION OF THE WORK. A SET OF REPRODUCIBLE CONTRACT DRAWINGS SHALL 9E OBTAINED FROM THE JNB TOiCOM PROJECT MANAGER. AND ALL CHANGES AS NOTED ON THE RECORD SET OF DRAWINGS SHALL BE INCORPORATED THEREON BY THE CONTRACTOR WITH BLACK INK IN A NEAT. LEGIBLE. UNDERSTANDABLE AND PROFESSIONAL MANNER. FAILURE TO KEEP RECORD DRAWINGS UP-TO-OATE SHALL CONSTITUTE CAUSE FOR WITHHOLDING OF PROGRESS PAYMENTS. 7. ALL INTERRUPTION OF ELECTRICAL POWER SHALL BE "KEPT TO A MINIMUM. HOWEVER. WHEN AN INTERRUPTION IS NECESSARY, THE SHUTDOWN MUST BE COORDINATED WITH THE OWNER AND THE LANDLORD 14 DAYS POOR TO DC OUTAGE. ANY OVERTIME PAY SHALL BE INCLUDED IN THE CONTRACTOR'S BID. WORK IN EXISTING SWITCHBOARDS OR PANELBOARDS SHALL BE COORDINATED WTTH THE LANDLORD PRIOR TO REMOVING ACCESS PANELS OR DOORS. 8. SHOP DRAWINGS SHALL BE SUBMITTED FOR ITEMS INDICATED ON PLANS. SHOP ORAIBNCS SHALL INCLUDE ALL DATA WITH CAPACITIES. SIZES. DIMENSIONS. CATALOG NUMBERS AND MANUFACTURER'S BROCHURES, 9 AFTER ALL REOUREMENTS OF THE SPECIFICATIONS AND/OR THE DRAWINGS HAVE 8EEN FULLY COMPLETED. REPRESENTATIVES OF COX COMMUNICATIONS PCS. LP WILL INSPECT THE WORK. THE CONTRACTOR SHALL PROVIDE COMPETENT PERSONNEL TO DEMONSTRATE THE OPERATION Of ANY ITEM OR SYSTEM TO THE FULL SATISFACTION OF THOSE REPRESENTATIVES. FINAL ACCEPTANCE OF THE WORK WILL BE MADE Bt COX COMMUNICATIONS PCS. LP AFTER RECEIPT OF APPROVAL AW RECOMMENDATION OF ACCEPTANCE FROM EACH REPRESENTATIVE. 10 THE CONTRACTOR SHALL FURNISH A ONE YEAR WRITTEN GUARANTEE ' OF MATERIALS AHD WORKMANSHIP FROM THE DATE OF SUBSTANTIAL COMPLETION. 12. COORDINATE WITH OTHER TRADES AS TO THE EXACT LOCATION OF THEIR RESPECTIVE EQUIPMENT. SUPPLY POWER AND MAKE CONNECTION TO EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS REVIEW THE DRAWINGS Of OTHER TRADES AND LOCATION OF EQUIPMENT. 13. EXACT METHOD AND LOCATION OF CONDUIT PENETRATIONS AND OPENINGS IN CONCRETE WALLS OR FLOORS OR STRUCTURAL STEEL MEMBERS SHALL BE AS DIRECTED BY THE STRUCTURAL ENGINEER. PERFORM CORING. SAWCUTTINC. PATCHING. AND REFINISHING OF EXISTING WALLS AND SURFACES WHEREVER IT IS NECESSARY TO PENETRATE. OPENINGS SHALL BE SEALED IN AN APPROVED METHOD TO MEET THE FIRE RATING OF THE PARTICULAR WALL. FLOOR OR CEILING. EXACT METHOD AND LOCATIONS OF CONDUIT PENETRATIONS AND OPENINGS N CONCRETE WALLS OR FLOORS SHALL BE UL APPROVED. 14. CONNECTIONS TO VIBRATING EQUIPMENT AND SEISMIC SEPARATIONS: UQUIO-nCHT FLEXIBLE STEEL CONDUIT IN DRY INTERIOR LOCATIONS AND IN AREAS EXPOSED TO WEATHER, DAMP LOCATIONS. CONNECTIONS TO TRANSFORMER ENCLOSURES. AND FINAL CONNECTIONS TO MOTORS. PROVIDE A SEPARATE INSULATED GROUNDING CONDUCTOR IN FLEXIBLE CONDUIT RUNS. MAXIMUM LENGTH SHALL BE SIX FEET UNLESS OTHERWISE NOTED. 15. ROUTE EXPOSED AND CONCEALED CONDUIT PARALLEL AND PERPENDICULAR TO WALLS AND ADJACENT PIPING. ARRANGE CONDUIT TO MAINTAIN HEADROOM AND TO PRESENT A NEAT APPEARANCE. 16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAWCUTTING. TRENCHING. BACKFILLING. COMPACTION AND PATCHING OF CONCRETE AND ASPHALT AS REQUIRED TO PERFORM HIS WORK. ATTENTION IS CALLED TO THE FACT THAT THERE ARE EXISTING UNDERGROUND UTILITY LINES. THE CONTRACTOR IS RESPONSIBLE FOR NOTIFICATION AND COORDINATION WITH ALL PROPERTY OWNERS. UTILITIES AND APPROPRIATE "DIG-ALERT" UNDERGROUND MARKING AGENCIES AND COMPANIES. THE CONTRACTOR SHALL ALWAYS USE EXTREME CAUTION WHEN TRENCHING FOR HIS WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER AND APPROVED REPAIR OF ANY AND ALL DAMAGES CAUSED BY HIM OR HIS WORK. 17. WHENEVER A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT. WIRE.EQUIPMENT DEVICES. CIRCLVT BREAKERS. GROUND FAULT PROTECTIONSYSTEMS. ETC. (ALL MATERIALS). ARISES ON THE DRAWINGS ORSPECIFICATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FORPROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THESTRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONSTO ENSURE COMPELTE AND OPERABLE SYSTEMS AS REQUIRED BYCOX COMMUNICATIONS PCS. LP AND THE ARCHITECT/ENGINEER. 18. UTILITY PENETRATIONS OF ANY KIND IN FIRE AND SMOKE PARTITIONSAND CEILING ASSEMBLIES, SHALL BE FIRESTOPPED AND SEALED WITHAN APPROVED MATERIAL SECURELY INSTALLED. 19. STRAIGHT FEEDER. BRANCH CIRCUIT. AND CONDUIT RUNS SHALL BEPROVIDED WITH SUFFICENT WEATHER PROOF PULL BOXES OR JUNCTIONBOXES TO LIMIT THE MAXIMUM LENGTH OF ANY SINGLE CABLEPULL TO 100 FEET. PULL BOXES SHALL BE SIZED PER CODE ORPER THE LATEST EDITIONS OF THE COX/SPRINT PCS SITE DESIGNSPECIFICATIONS MANUAL AND THE BTS TELCO INTERCONNECT CONDUITREQUIREMENTS WHICHEVER IS MOST RESTRICTIVE. LOCATIONS SHALLBE DETERMINED IN THE FIELD OR AS INDICATED ON THE DRAWINGS. 20. MAXIMUM NUMBER OF CONDUCTORS IN OUTLET OR JUNCTION BOXESSHALL CONFORM 70 THE NATIONAL ELECTRICAL CODC AMD ALLAPPLICABLE LOCAL CODES. 21. IDENTIFICATION NAME PLATES SHALL BE MICARTA 1/8 INCH THICKAND OF APPROVED SIZE WITH BEVELED EDGES AND ENGRAVED WHITELETTERS A MINIMUM OF 1/4 INCH HIGH ON BLACK BACKGROUND.NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICEDISTRIBUTION AND POWER DISTRIBUTION SWITCH BOARDS OR PANELBOARDS. DISCONNECTING SWITCHES. TRANSFORMERS. TERMINAL CABINETS.TELEPHONE CABINETS, ETC. ALL NAMEPLATES SHALL BE ATTACHEDWITH SCREWS. PULL BOXES. JUNCTION BOXES. AND DEVICE BOXESSHALL BE MARKED WITH A PERMANENT MARKER. 22. THE EXACT LOCATION OF ALL ELECTRICAL DEVICES AND EQUIPMENTSHALL BE COORDINATED WITH THE PLANS AND DETAILS. PRIORTO INSTALLATION. 23. DRAWINGS ARE DIAGRAMMATIC ONLY. ROUTING OF RACEWAYS SHALL8E AT THE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTEDAND SHALL BE COORDINATED WITH OTHER SECTIONS. DO NOT SCALETHE ELECTRICAL DRAWINGS FOR LOCATIONS OF ANY ELECTRICAL,ARCHITECTURAL. STRUCTURAL. CMU OR MECHANICAL ITEMS OR FEATURES. GROUNDED. PIN AND~SLEEVE TYPE WITH MOUNTING BOX (APPLETON /ADJA I033-150RS). 25 RIGID GALVANIZED STEEL CONDUIT FITTINGS SHALL BE FULL WEIGHT THREADED TYPE. ELECTRICAL METALLIC TU8INC (EMT) MAY BE USED IN WALLS OR CEILING SPACES WHERE NOT SUBJECT TO MECHANICAL DAMAGE. PVC SCHEDULE 80 MAY BE INSTALLED BENEATH SLAB OR BELOW GRADE. AN EQUIPMENT GROUNDING CONDUCTOR SHALL 8E PROVIDED IN ALL CONDUIT RUNS. 26. RIGID GALVANIZED STEEL CONDUIT FITTINGS SHALL BE THREADED AND THOROUGHLY GALVANIZED. ELEOBCAL METALLIC TUBING (EMT) CONDUIT FITTINGS SHALL BE STEEL. RAINTIGHT THREADLESS COMPRESSION TYPE. DIE CAST, SET SCREW. OR INDENTER TYPES ARE NOT ACCEPTABLE. SET SCREW TYPE IS NOT ACCEPTABLE. 27. ALL TELCO CONDUIT INSTALLATIONS AND OTHER EMPTY CONDUIT RUNS AND STUBS SHALL INCLUDE A 3/8' POLYPROPYLENE PULL STRING. 28. ALL CONDUCTORS SHALL BE COPPER #12 AWC MINIMUM SIZE. TYPE THHN/THWN THERMOPLASTIC. 600 VOLT. 75 DEGREES CELSIUS WET AND 90 DEGREES CELSIUS DRY AND UL LISTED UNLESS NOTED OTHERWISE. CONDUCTORS *12 AWG AND SMALLER SHALL BE SOLID. CONDUCTORS #10 AWG AND LARGER SHALL BE STRANDED. 29. JUNCTION AND PULL BOXES: FOR INTERIOR DRY LOCATIONS. BOXES SHALL BE GALVANIZED ONE-PIECE. DRAWN STEEL, KNOCKOUT TYPE WITH REMOVABLE MACHINE SCREW SECURED COVERS. FOR OUTSIDE. DAMP. OR SURFACE LOCATIONS, BOXES SHALL BE HEAVY CAST ALUMINUM OR CAST IRON WITH REMOVABLE. GASKETED. NON-FERROUS MACHINE SCREW SECURED COVERS. BOXES SHALL BE SIZED FOR THE NUMBER AND SIZES OF CONDUCTORS AND CONDUIT ENTERING THE BOX AND EQUIPPED WITH PLASTER EXTENSION RINGS WHERE REQUIRED. BOXES SHALL BE LABELED TO INDICATE PANEL AND CIRCUIT NUMBER. OR TYPE OF SIGNAL OR COMMUNICATIONS SYSTEM. 30. ALL OUTDOOR ELECTRICAL DEVICES OR EQUIPMENT SHALL BE OF WEATHERPROOF TYPE. 31. ALL EQUIPMENT, MONOPOLE. FRAME. CABLE TRAY AND ANTENNA GROUND WIRE CONNECTIONS TO GROUND BUSSES SHALL BE MADE WITH CRIMP TYPE COMPRESSION CONNECTIONS TO CONNECTORS (MINIMUM 2 HOLE LUGS WITH FULL BOLTING). BUSS SHALL BE PRE-DR1LLED TO ACCOMMODATE ALL CONNECTORS. ALL GROUNDING SHALL BE PER N.E.C. SECTION 250 AND 810 AND THE GROUNDING REQUIREMENTS OF THESE DRAWINGS AND THE COX/SPRINT PCS SITE DESIGN SPECIFICATIONS MANUAL. 33. ALL GROUND WIRE CONNECTIONS BETWEEN GROUND BUSSES AND OTHER GROUND BUSSES AND GROUND RODS SHALL BE CADWELOEO OR IRREVERSIBLE COMPRESSION TYPE CONNECTORS. 34. ALL METAUC GROUND WIRE CONDUIT SHALL BE GROUNDED TO THE GROUND WIRt' USING SET SCREW CONNECTIONS AT CONDUIT END CAPS AND CRIMP CONNECTIONS AT WIRE. SEE DETAIL 35. COAT ALL BOLTED LUC it BUSS GROUND CONTACT SURFACES WITH KOPR-SHIELD. NO-OX. OR EQUAL PRIOR TO ATTACHMENT. 36. MAIN CIRCUIT BREAKER SHALL BE RATED FOR STANDARD A.I.C. RATING HIGHER THAN INCOMING A.I.C. 37. ALL EQUIPMENT SHALL 8E U.L LISTED. 38. ALL EQUIPMENT SHALL BE BRACED FOR STANDARD A.I.C. RATING HIGHER THAN INCOMING FROM UTILITY CO. 39. ALL CORING CLEARANCES SHALL BE FIELD VERIFIED AND ALL CONDUIT ROUTING SHALL BE COORDINATED WITH BUILDING OWNERS REPRESENTATIVE. 40. ALL CONNECTIONS TO EXISTING MAIN SW1TCHCEAR INCLUDING -BUS-TAPS' AND/OR "HOT-TAPS' REQUIRE CERTIFICATION AND APPROVAL FABRICATION AND CERTIFICATION SHALL BE FURNISHED BY A CONTRACTOR APPROVED BY THE APPLICABLE UTILITY. 41. CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANIES FOR FINAL AND EXACT WORK AND MATERIAL REQUIREMENTS. CONSTRUCT TO UTILITY COMPANIES ENGINEERING PLANS AND SPECIFICATIONS ONLY. 42. ALL BROCHURES. OPERATION MANUALS. CATALOGS. SHOP DRAWINGS. ETC. SHALL BE TURNED OVER TO THE JNB TELECOM CONSTRUCTION MANAGER AT THE COMPLETION OF WORK. CONDUIT RUN UNDERGROUND (LINE WEIGHT VARIES) 3 CONDUIT STUBBED OUT AND CAPPED —T— TELEPHONE CONDUIT RUN WITH PULL STRING IN PLACE Q) PROTA8LE GENERATOR RECEPTICAL U I DISCONNECT SWITCH (•) GROUND ROD •<J>- LIGHT FIXTURE r°~1 MANUAL TRANSFER SWITCH AND REVERSE GENERATOR RECEPTACLE FUSED DISCONNECT MANUAL TRANSFER SWITCH TELEPHONE TERMINAL BACKBOARD "TTB". 3/4' SANDED AND PAINTED CDX PLYWOOD. UNLESS NOTED OTHERWISE. A "AMPS" AFF ABOVE FINISHED FLOOR AGB ANTENNA GROUND BUS BAR AtC "AMPERES INTERRUPTING CAPACITY" C. "CONDUIT. WITH CONDUCTORS AS REQUIRED BY DRAAWINGS OR SPECIFICATIONS C.O. "CONDUIT ONLY". PROVIDE MINIMUM (l) PULL STRING IN EACH EMPTY CONDUIT GND GROUND (j) JUNCTION BOX KVA "KILOVOLT - AMPERES" KW "KILOWATT MGB MAIN GROUND BUS BAR MTS MANUAL TRANSFER SWITCH O.C. "ON CENTER" SGB SECTOR GROUND BUS BAR UNO UNLESS NOTED OTHERWISE V "VOLTS" WP WEATHERPROOF. NEMA 3R 9/10/97 DRAWN BY: RJR CHECKED BY: W8 REVISIONS DATE OeSCRFTlON IWT1AL PROPRIETARY INFORMATION IX MTOfeMDOM CammtO N IMS SET OFCOtSTRUCnON DOCUMENTS 8 PBOPWtTARr BY NATURC. Mff USE OH OOCUMUtt OTHER TWINwcjwoj BLOB meat catueuaxt PCS. LP.s snacnr cramm. SOUTH PALOMAR 5858 GDSQN PLACE CARLSBAD, CA 92006 JOB# SO145 ELECTRICAL NOTES SYMBOLS CASE NUMBER E-1 NEW TRANSFORMER NEW SOG*E MEIER AHO EXISTINGTOCOUPOE DUSTING MAIN SWITCHBOARD 2* SCHEDULE 80 PVC TELEPHONE SERVICE CONDOtT WITH 1/8" PULL SIRING DOWN ADJACENT WALL TO TELEPHONE JUNCTION BOX ACROSS CQUNC THROUGH WAREHOUSE ELEVATION ± 23* DOWN AD4ACEKT WALL TO MANUAL TRANSFER SWITCH AND GENERATOR RECEPTACLE SEE POWER PLAN BELOW -LOCATE GROUND RODSIN PLANTER AREA SEE POWER PLAN BELOW UTILITY RUN PLAN SEE UTILITY RUN ABOVE -FOR TELCO SERVICE SEE UTTUTY RUN ABOVE FORELECTRICAL SEKriCE KEYED NOTES: CONSTRUCTION & SEE POWER SINGLE LINE DIAGRAM^ SHEET E-3 <^> ELECTRICAL SERVICE FROM METER ^> 1* PVC CONDUIT FOR GROUND <4> EXISTING CURB O LOADING DOCK ^5> PRIMARY BASE TRANSCEIVER STATIONNX (BTS) LOCATION < <6> EXPANSION CABINET < <9> PRIMARY POWER CABINET < <|> BATTERY CABINET < <j£> AUXILIARY CABINET < <^> ANTENNA COVER ASSEMBLY <^J> COX COMMUNICATIONS GPS ANTENNA ^ UNISTRUT PI 001 ATTACHED WITH 1/2'«^^ M.B. TO OtSTHC OBNET LFTNG HOLES <N ACCOnMNCE WITH COX/SPRWT PCS SITE 0€S10N SPCCtnCADOMS MMWM. <{^> PROVIDE LIGHT FIXTURE. ENCLOSED AND ^ GASKETED. ISO WATT INCANDESCENT LAMP.GLASS GLOBE AND GUARD. MOUNTED ONWEATHERPROOF JUNCTION BOX PROVIDEVf C-2 112 * \ |12 CND TO KNOCKOUT <IN SIDE OF PRIMARY POWER CABINET 2CM-1P BRANCH ORCUT BREAKER SECTION < rffe Q£CrmCAL OeCONHECT SWITCH ON <v UNISTRUT ANCHORED TO WALL rfb MANUAL TRANSFER SWITCH CM UMSTRUT^^ ANCHORED TO WALL PLAN $> REVERSE SERVICE GENERATOR fi> CONOWT TO MANUAL TRANSFER SWITCH (p IB"" COAXIAL CABLE TRAY.^- (^ r SCHEDULE 80 TOEPHONE SERVICE^ WITH 3/8* PUU STRING AND TRUI MEASURING STRIP x 3 *S- Pt** CONCRETE EQUIPMENT CURB AND SLAB »'-«• HGH CHMKLIKK GATES W/PAD LOCK CONCRETE BLOCK WALL CONCRETE WALK & LANDING EXTENDED TO EDGE OF PARKING EXISTTNC ROOF ORAIN OUTLETS TO REMAIN UAJN GROUND BUS (MOB) 3/4' PVC SgCDULC 80 CONDUIT WITHSOLO M COPPER STRANDED TELCO GROUNDNGWRE. STUB ABOVE LOWER SHELF OF AWOLWffCABIHET. TERMINATE WIRE AT UAIH GROUND BUS WTTH APPROVED DOUBLE LUC CONNECTION AND LEAVE 5' OF THE *« COILED AT THE AUXILIARY CABINET FOR TELCO INSTALLATION GROUND ROD TEST BOX (TYPICAL) GROUND ROCS (TYPICAL) EXTERIOR WALL OF EXISTING BUILDING SOUTH PALOMAR sasa EDSON PLACE CARLSBAD. CA 92008 JOB# SD145 POWER PLAN CASE NUMBER POWER PLAN E-2 2* C- 3 fl.t 13 CRO EXISTING MAM SWITCH BOARD LIQUID TIGHT FLEXIBLE CONDUIT EXISTING SERVICE GROUND 3/4* C- 2 f 6.1 |10 GRO 2*C 3 fl.1 |6 GRD PRIMARY POWER CABINET POWER SINGLE LINE DIAGRAM NOTES (T) ELECTRICAL SERVICE COMBINATION METERING AND MAM DISCONNECT. ^ 100 AMPERE. 277/480 VOLT. THREE PHASE. 3 POLE. 4-WRE. ALWALT 1217 MTBP MS-IS COMMERCIAL METER-PULLOUT COMBNATTON SAFETY BOX AND TEST BY-PASS FACfUTIES. MANUAL PULL-OUT 40 AMPERE CLASS T FUSES IN PHASES *A* * "B' ONLY. BUSSUANN fJJS. C.L, FA 42.000 A.I.C NEMA 1 ENCLOSURE (2) 100 AMP. 240 VOLT. 2 POLE. DOUBLE THROW. NON FUSED. MANUAL ^ TRANSFER SWITCH. SQUARE "0* fOTU 223 NRB, NEMA 3R ENCLOSURE. (3) 100 AMP. 240 VOLT, 2 POLE, HEAVY DUTY FUSED DISCONNECT SWITCH. ^ SIEMENS fNR 323 SERIES A. NEMA 3R ENCLOSURE CLASS RK1 FUSES. BUSSMANN TYPE KWN-R. CJ_. FA. 100 AMP (7) 100 AMP. 2 POLE, 3 WIRE. 240 VOLT REVERSE SERVICE WEATHERPROOF^ RECEPTACLE 'APPLETON* fADJA t033-124RS. (?) DRY TYPE TRANSFORMER. 25 KVA 480 VOLTS. SINGLE PHASE TO ^ 120/240 VOLTS SINGLE PHASE, 3 WIRE SQUARE 0 CO. |25S40F 20' HIGH x 16* WIDE x 14* DEEP 300 POUNDS. MOUNT ON BRACKET ABOVE METER (?) TAP EXISTING 800 AMPERE 277/480 VOLT. 3 PHASE, 4 WIRE MAMs-^ SWITCHBOARD UNDERGROUND PULL-SECTION BUS TAPS REQUIRE CERTIFICATION AND APPROVAL. FABRICATION AND CERTIFICATION SHALL BE FURNISHED BY PACIFIC ELECTRIC CO. TEMECULA. CA DON CARTWRK3HT. (909) 676-3374 (7) PREVIOUS YEAR'S PEAK DEMAND LOAD x 1.25 + NEW LOAD TOTAL IS ^ UNDER 660 AMPERES (a) COX COMMUNICATIONS PCS. INC. PRIMARY POWER CABINET (?) FINAL CONNECTION WITH 36' OF 2* UQUID TIGHT FLEXIBLE METAL CONDUIT. (fo) TRANSFORMER GROUNDING. 3/4* C - 1 f4 ft (1) 3/4* x 10' COPPER ^ CLAD STEEL GROUND ROD PER CODE (jj) LOCATE SWITCH ADJACENT TO TRANSFORMER . (12) SERVICE GROUND: 3/4*C - 1 f4 BOND TO EXISTING BUHJXNG MAIN ^ SWITCHBOARD SERVICE POWER SINGLE LINE DIAGRAM/ INSIDE EDGE (TYPICAL) MOUNTING HOLES (VERIFY) PUCE 3/4* BACKBOARD IN FRONT OF MOUNTING CHANNEL. BACKBOARD SHALL BE PLACED BY COX FIELD TECHNICIAN TELCO BACKBOARD CABINET MOUNTING CHANNEL GROUNDCONDUIT NOTE: THE SECOND SHELF IN THE AUX CABINET WILL REQUIRE TWO CUTOUT PENETRATIONS TO MATCH THE HOLES CUT IN THE BOTTOM OF THE CABINET TO SUPPORT TELCO AND GRD. THE TELCO CONDUIT HOLE SIZE SHOULD BE A MINIMUM 2*. THE GRO CONDUIT CUTOUT SHOULD BC A MINIMUM OF 3/4*. PLEASE NOTE THAT THESE MEASUREMENTS PROVIDED ARE 'CENTERUNE MEASUREMENTS. OTHER SIZE MODIFICATIONS OF THE SHELF CUTOUTS COULD BE APPLICABLE. PENDING APPROVAL BY COX INTERCONNECT ENGINEER. IT IS MANDATORY TO MAKE SURE THAT THE CONDUIT PENETRATIONSARE IN FRONT OF THE TELCO BACKBOARD IN THE AUX CABINET. INSIDE EDGE (TYPICAL) 9/10/97 DRAWN BY: RJR CHECKED BY: WB REVISIONS DATE OESCfflPTON NflMi. «ICXIT<CTI>»< H runtime IOUTH PALOMAR 5858 EDISON PLACE CMLS8AD. CA 92006 OB# SO145 SINGLE UNE DIAGRAM ELECTRICAL CLOSET CASE NUMBER AUXILIARY CABINET 1/2*-E-3 THIS SCHEMATIC DIAGRAM IS SHOWN TO ILLUSTRATE GENERALSYSTEM RELATIONSHIPS AND CONNECTION DESCRIPTIONS.ACTUAL INSTALLATION DETAILS. LENGTHS OF CABLES ANDCONDUCTORS, MOUNTING POSITIONS AND ROUTES MAY VARYDUE TO SJTE SPECIFIC CONOTONS. CABLE TRAY SECTIONS (TYPICAL) COAXIAL CABLE RUNSTO CABINETS VIA CABLETRAY (TYPICAL)ui m "AGB" 3* x 12' x 1/+" GROUND BUS MOUNTED ON PORCELAININSULATORS ON OR NEAR BASEOF BUILDING WALL 1 12 AWC STRANDED INSULATED PROVIDE 1 feCOPPER JUMPERS WITH (2) HOLE LUGS ORCOX APPROVED JUMPERPLATES BETWEEN EACHSECTION OF CABLE TRAY GROUND FORCOAXIAL CABLEPER MANUFACTURERSRECOMMENDATIONS COAXIAL CABLE RUNS TO BTS CABINETS VIACABLE TRAY / i i i i / f 2 AWC STRANDED INSULATED TOCABLE TRAY t f2 AWCSTRANDEDINSULATED BURNDY YGHC ZC2 CONNECTOR O O |2 AWG STRANDED INSULATED TO CABLE TRAY 1 f2 AWG STRANDEDINSULATED BURNDY YGHC •2C2 CONNECTOR JZ AWG STRANDEDINSULATED TOCABLE TRAY MGB' COPPER 4* x 18' x~ \/f 7 GROUND BUS MOUNTED ON / PORCELAIN INSULATORS ON/UNtSTRUT POSTS / ALL GROUNDING OF CABINETS-AND EQUIPMENT INCLUDING, SIZE.'TYPE 4 LOCATION SHALL BE BY OTHERS COX BTS EQUIPMENT CABINETASSEMBLY MAIN GROUND LEAD1* C-1 #2/0 STRANDEDINSULATED BURNDY YCH TYPE CONNECTORS (TYPICAL) MAIN GROUND LEAD TO TESTBOX AT GROUNDING RING 9/10/97 DRAWN BY: RJR GROUND FOR COAXIAL CABLEPER MANUFACTURERS RECOMMENDATIONS (2) HOLE LUC CONNECTION (TYPICAL) "SGB1 • COPPER 2* x 6' x 1/4* GROUND BUS MOUNTED TO CABLE TRAY ONPORCELAIN INSULATORS (TYPICAL OF 3) 1 f2 AWG STRANDEDINSULATED GROUNDLEAD FROM FARTHESTANTENNA LOCATION TOANTENNA GROUND BUS(ACB) VIA CABLE TRAY CHECKED BY: W8 REVISIONS DATE OESCRFTWN CROUKDMC RMO LOCATEDAT GRADE TEST BOX SOUTH PALOWAR 5BS8 EDISON PLACE CARLSBAD. CA 92000 JOB# SD145 GROUNDING NOTES & DETAILS CASE NUMBER GROUNDING SCHEMATIC MOT TO SOU E-4 EQUIPMENTGROUND(TYPICAL) BY COMPRESSIONLUC (OR EQUAL) COPPER GROUND BUS BAR. AS MANUFACTURED BY BURNDY, NEWTON. B-UNE OR EQUAL COMPRESSIONLUC (OR EQUAL) MOUNTHCHOUI FDR SUPPORT BRACKET WITH PORCELAIN MSULATOR (TYPICAL) |2 SOLID COPPERTO EQUIPMENTSUPPORT FRAME(TYPICAL) 12/0 STRANDEDCOPPER TOBUILDING STEELOR GROUND RODS (TYPICAL) ' TYPICAL DETAIL SCALEr-r-o' 5/8* «•• (TYPICAL) 5/8'» (TYPICAL OF 2) ANTENNA GROUND BUS BAR "AGB" SET SCREW CLAMP ON END CLAMP EMT CONDUT GROUND WIRE CU. CRIMP CONNECTION WEATHER PROTECTED TAPE BALL END CAP 4' r-1-3/4* (TYPICAL OF 1/2"# (TYPICAL OF 6} 5/8'* (TYPICAL OF 2) MAIN GROUND BUS BAR "MGB" 5/8" TYPICAL—^ SPACING BOTH ^^ WAYS •BURNDY TYPE YA2CL-2TCU LUG (OR EQUAL) 5/«*» (TYPICAL OF 2) 1/4'» (TYPICAL OF 12) STRANDED GROUND FARTHEST ANTENNA -BURNDY TYPE YCHC2C2 CONNECTOR (OR EQUAL) SECTOR GROUND BUS BAR "SGB".1-1/2 - 1-0 CHAtNUNK GATE ASSEMBLY ALL STia FENCE AND ALL HNCE POSTS ADJACENT TO GATES (TYPICAL) MECHANICAL TYPE CONNECTOR WITH BRACED COPPER JUMPER TO GATE POST. BURNDY TYPE GG (OR EQUAL) MECHANICAL TYPE CONNECTOR TO HINGE POST OR FENCE POST. BURNDY TYPE CAR (OR EQUAL) '** GRADE f 2 SOU) COPPER. 12* RADIUS CONCRETE FOOTWC O FENCE POST (TYPICAL) FINISH GRADE f 2 SOLID BARE COPPER (TYPICAL) BURNDY TYPE YGHP-S8C2W-2TN CONNECTOR (TYPICAL) NOTE: . : GROUND RODS SHALL HAVE A CONCRETE BOX AT ALL TEST POINTS (SEE DETAIL '6/E5*) GROUNDING RING SCALE N.T.S. MAM GROUND BUS ON PORCELAM MSUATORS SEE OETAB. "2/tS'. CENTER BEHMD PRMARY POWER CASKET EQUPUEMT CURB S/T# BOLT WITH VB* SHWG NUTS CROUND BUS CONCRETE APftON SLAB BROOKS CONCRETEDBox-e s/v wsioe DIA,x12* DEEP BURNOY TYPE YGMP-58C2W-2TN CONNECTOR 12 SOLID BARE COPPER TO NEXT GROUND ROD 5/8' x e'-fl' COPPQ? CLAD STEEL GROUND SOD f2/0 SOUD BARE OOPP0TTHNSmCN TO f2/D STRANDED COPPER AT «* ABOVE GRADE WITH BYRNDYTYPE YGHP- SBC2V-2TN CONNECTOR NOTE: Ail CONDUT BELOW CRATE SHALL BE PVC SCHEDULE 40 GROUNDING GENERAL NOTES FOR DFTAILS j 5 k 6 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL GROUNDING INSTALLATION AND MOUNTING MAY VARY DUE TO SITE SPECIFIC CONDfllONS. 2. GROUND ROD SHALL BE COPPER CLAD STEEL '5/8* DIAMETER. 8 FEET LONG. PROVIDEMINIMUM OF FOUR (4) GROUND RODS TOACHIEVE 5 OHMS OR LESS GROUND RESISTANT. 3. CONTRACTOR SHALL MEGGAR GROUND RESISTANCE AT MSB" TO VERFYTHAT RESISTANCE SHALL NOT EXCEED S OHMS AND SHALL SUBMITAN,INDEPENDENT TESTMC REPORT WDKATNG RESISTANCE VALUES .,OBTAINED:- CONTRACTOR SHALL PROVIDE GROUND RODS. MAXIMUM(4) TOTAL AT NO ADD010NAL COST. AS REQUIRED TO ATTAIN TWSVALUE OR LESS. WHERE MULTFLE GROUND RODS ARE INSTALLED.THEY SHALL NOT BE LESS THAT 8 FEET NOR MORE THAN 16 FEETAPART UNLESS APPROVED BY MB TELECOM PROJECT MANAGER, 4. TESTING: PERFORM FALL OF POTENTIAL TESTPER IEEE STANDARD NO. 81. SECTION 9.04 ONTHE MAIN GROUNDING ELECTRODE. 5. CONCRETE PRECAST BOX WITH TRAFFIC COVER (BROOKS/1 -RT)TYPE TO FIT CWR THE GROUND CONNECTION. COVER SHAILBE OF CAST RON AND SHALL BE ENGRAVED "SIGNAL GROUND*. 6. USE MINIMUM J2/0 AWG COPPER CONDUCTORFOR COMMUNICATION SERVICE GROUNDINGCONDUCTOR. 7. INSTALL GROUNDING AND BONDING CONDUCTORS WITHSUFFICIENT SLACK TO AVOID BREAKING DUE TOAND MOVEMENT OF CONDUCTOR AT ATTACHED POINTS. GROUND WELL TEST BOX NOT TO SCALE IX INrOKUMWH CCIftNNtD K TWS SO OfcoNSiaucnoN DOCUMENTS s PWOPHTWT BY MMURL «NT list OK OGCUSUK ODCR TKUt THUWHICH RtlATCS TO COX COMMUNICATIONS PCS. UP. IS SITOCUT PdOHBtTOX 9/10/97 DRAWN BY: RJR CHECKED BT: WB REVISIONS DATE OeSCRPTION NTtlALJ OUTH PALOMAR 5858 EDtSCN PLACEJWLSBAD. CA 92006 OB# SDL45,-- -to..jr -^feijaip-viy-- GROUNDING DETAILS CASE NUMBER CONDUIT GROUND CONNECTION SCALE M.T.S.FENCE GROUNDING MAIN GROUND BUS ANCHOR | 3-!^- | 9 10 F-5