HomeMy WebLinkAboutMCUP 13-07; Taylormade Verizon Wireless; Conditional Use Permit (CUP) (3)VICINITY MAP
SITE
I
THOMAS GUIDE PAGE: 1127 -D1
ADDRESS
5541 FERMI COURT
CARLSBAD, CA 92008
DIRECTIONS:
(FROM VZW'S OFFICES IN IRVINE): FROM 15505 SAND CANYON
AVENUE, IRVINE, CA 92618, HEAD TOWARD WATERWORKS WAY
ON SAND CANYON AVENUE, TAKE 1-405 SOUTH. EXIT PALOMAR
AIRPORT ROAD AND TURN LEFT. TURN SHARP LEFT ON COLLEGE
BLVD, TURt-1 RIGHT ONTO SALK AVEt-IUE, TURN LErT ON fERMI
COURT. BUILDING WILL BE ON THE LErT SIDE AT THE END OF
CUL-DE-SAC. TRIP TAKES APPROXIMATELY 55 MINUTES.
CffY OF CARLSBAD
Administrative Permit
........ )If ........................ ·.· .. .
CaseNo. CUP /3-0?
•
1re ess
TAYLORMADE
5541 FERMI COURT
CARLSBAD, CA 92008
CONSULTANT TEAM
ARCHITECT:
BOOTH 1: ~SUAREZ ARCHITECTURE, INC.
325 CALSBAD VILlAGE DRIVE, SUITE D2
CARLSBAD, CA 92008
(760) 434-8474
(760) 434-8596 (FAX)
LEASING/PLANNING:
M&M TELECOM INC.
LEASING
NICOLE MEYERS
6886 MIMOSA DRIVE
CARLSBAD, CA 9 2011
(619) 602-5600
nlcole.meyersOmmtelecomlnc.com
PlANNING
DOUG MUNSON
PO BOX 55
POWAY, CA 92064
(760) 390-7727
doug.munsonOmmtelecomlnc.com
SURVEYOR:
JRN CIVIL ENGINEERS
232 AVENIDA FABRICANTE, SUITE 107
SAN CLEMENTE, CA 92672
(949) 2481-4685
PERMITS REQUIRED
e MINOR USE PERMIT
SCALE
THE DRAWING SCALES SHOWN IN THIS SET REPRESENT THE
CORRECT SCALE ONLY WHEN THESE DRAWINGS ARE PRINTED IN A
24" ~ 36" FORMAT. IF THIS DRAWING SET IS NOT 24" x 36", THIS
SET IS NOT TO SCALE. ALL DRAWINGS ARE SCHEMATIC. DO NOT
SCALE DRAWINGS TO DETERMINE OR VERIFY ANY 011-AENSIONS.
DRAWINGS OF ANY SIZE SHALL NEVER BE SCALED FOR ANYTHING
OTHER THAN GENERAL REFERENCE.
PROJECT SUMMARY
APPLICANT: VERIZON WIRELESS
15505 SAND CANYON AVENUE
IRVINE, CA 92618
CONTACT: NICOLE MEYERS, MI:M TELCOM INC.
PHONE: (619) 602-5600
OWNER: FERMI COURT L.P.
1800 THIBODO RD. #320
VISTA, CA 92081
SITE CONTACT: STEVE CHATFIELD
OF GREENE PROPERTIES, INC.
(619) 708-3302
(760) 727-6888 x1167
PROJECT DESCRIPTION:
e PROPOSED VERIZON WIRELESS TELECOMMUNICATIONS
EQUIPMENT RACKS INSIDE A NEW EQUIPUENT ROOM
ON 1ST FLOOR OF EXISTING BUILDING
e INSTALlATION OF" VERIZON WIRELESS MECHANICAL UNITS
BEHIND NEW SCREENED ENCLOSURE ON ROOF Of EXISTING
BUILDING
e INSTALlATION OF (3) THREE VERIZON WIRELESS ANTENNA
SECTORS, Of (4) FOUR ANTENNAS EACH (TOTAL Of (12)
TWELVE ANTENNAS) MOUNTED INSIDE A NEW ANTENNA TOWER
BEHIND RF" TRANSPARENT SCREENS.
e INSTALlATION OF FOUR (4) VERIZON WIRELESS RRU UNITS PER
SECTOR (TOTAL OF TWELVE (12) RRU'S) MOUNTED INSIDE A
NEW ANTENNA TOWER.
e INSTALlATION OF ONE (1) VERIZON WIRELESS 2'-0"11
MICROWAVE DISH ANTENNA (FOR TELCO SERVICE FEED)
MOUNTED INSIDE-A NEW ANTENNA TOWER BEHIND
Rf TRANSPARENT SCREENS.
e INSTALlATION OF TWO (2) VERIZON WIRELESS E/911 GPS
ANTENNAS
e INSTALlATION OF A 30kW ENCLOSED EMERGENCY GENERATOR
WITH A 148 GALLON DIESEL TANK ON A CONCRETE PAD
WITIH A CONTAINMENT CURB INSIDE A NEW CONCRETE BLOCK
WALL ENCLOSURE.
e INSTALlATION OF NEW 200 AMP ELECTRICAL SERVICE FROio! AN
EXISTING ELECTRICAL ROOM AT 1ST FLOOR FLOOR
e INSTALlATION OF" A NEW TELCO SERVICE CONNECTION FROM AN
EXISTING TELCO ROOM AT 1ST FLOOR
e NO LANDSCAPE OR IRRIGATION IS PlANNED FOR THIS PROJECT
PROJECT ADDRESS: 5541 FERMI COURT
CARLSBAD, CA 92008
ASSESSORS PARCEL NUMBER: 212-130-50-00
EXISTING ZONING: C-IA
TOTAL SITE AREA: 160,082 S.F. = 3.67 ACRES
PROPOSED EQUIPMENT
ROOM AREA: 248 s.F.
PROPOSED GENERATOR
ENCLOSURE AREA: 144 s.F.
EXISTING OCCUPANCY:
PROPOSED OCCUPANCY:
EXISTING TYPE Of
CONSTRUCTION:
PROPOSED TYPE Of
CONSTRUCTION:
B
B
TYPE V-B
(SPRINKLERED)
TYPE V-B
NOTE: THERE ARE NO EXISTING TELECOMMUNICATION FACILITIES ON
THIS PROPERTY
SHEET SCHEDULE
T-1 TITLE SHEET AND PROJECT DATA
A-0 SITE PIAN
A-1 GENERA TOR PIAN
A-2 EQUIPUENT FLOOR PIAN
A-3 ROOF PIAN
A-4 ANTENNA PlANS
A-5 EXTERIOR ELEVATIONS
A-6 EXTERIOR ELEVATIONS
A-7 GENERATOR ELEVATIONS
C-1 TOPOGRAPHIC SURVEY
APPLICABLE CODES
ALL WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES:
CALIFORNIA STATE BUILDING CODE, TITLE 24, 2010 EDITION
CALIFORNIA PLUMBING CODE, 2010 EDITION
CALIFORNIA MECHANICAL CODE, 2010 EDITION
CALIFORNIA ELECTRICAL CODE, 2010 EDITION
CALIFORNIA FIRE CODE, 2010 EDITION
CALIFORNIA ENERGY CODE, 2010 EDITION
IN THE EVENT OF CONFLICT, THE MOST RESTRICTIVE CODE
SHALL PREVAIL
ACCESSIBILITY DISCLAIMER
THIS PROJECT IS AN UNOCCUPIED WIRELESS PCS
TELECOMMUNICATIONS FACILITY ANO, ACCORDING TO WRITTEN
INTERPRETATION FROM THE CALIFORt-IIA DEPARTMENT OF THE STATE
ARCHITECT, IS EXEMPT FROM DISABLED ACCESS REQUIREMENTS.
~RCHITECTURE II INCOIHORIITED
3~5 CARlSDAD VIllAGE DRIVE. SUITED~
CAHSDAD. CA 9~008 (760) 434·6474
============= == ==============
PREPARED FOR
P.O. BOX 19707
IRVINE, CA 92623-9707
(949) 286-7000
.. ..
APPROVALS
A&:C DATE
RE DATE
RF DATE
INT DATE
EE/IN DATE
OPS
EE/OUT
DATE
DATE
•• ••
PROJECT NAME
TAYLORMADE
5541 FERMI COURT
CARLSBAD, CA 92008
SAN DIEGO COUNTY
================ ===============
03/27/13
04/16/13
04/19/13
04/22/13
04/25/13
06/17/13
DRAWING DATES
80% ZD (se)
90% ZD (se)
100% ZD (se)
1 A CERT. 1 DDX ZD (rd)
OWNER REV. 1 DO% ZD (rd)
PLANNING R£\1, 100% ZD (rd)
================ ===============
SHEET TITLE
TITlE SHEET
&
PROJECT DATA
================ ===============
PROJECTS\ \IERIZON\ 13127
===== == ====
T-1
I
SETBACKS:
NO FRONT OR SIDE YARD
SETBACK IS REQUIRED
LAND DOES NOT INCLUDE RIGHTS ----.._
OF ACCESS TO OR FROM STREET
ABUTTING SAID LAND
EXISTING EASEMENT------..__
FOR WATER FACILITIES
EXISTING LANDSCAPE AREA ---.._
PROPOSED VERIZON WIRELESS ANTENNAS
MOUNTED INSIDE A NEW ANTENNA TOWER t---~
BEHIND RF TRANSPARENT SCREENS.
PROPOSED ELECTRICAL CONDUITS FOR -----
GENERATOR ROUTING ABOVE CEILING
IN 1ST FLOOR
PROPOSED ELECTRICAL CONDUITS FOR ----
GENERATOR ROUTING INSIDE EXISTING
BUILDING COLUMN TO GRADE
PROPOSED UNDERGROUND ------
ELECTRICAL CONDUIT TRENCH
EXISTING ASPHALT---------
PAVED PARKING LOT
PROPOSED VERIZON WIRELESS ENCLOSED --..__
EMERGENCY GENERATOR INSIDE A NEW
CONCRETE BLOCK WALL ENCLOSURE WITH I
A CHAIN UNK LID I
I
I
~/
*' 411 il
411 ~I _,I
8t
I
SEE SHEET A-1 FOR 1--'
GENERATOR PLAN
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I t
I
I
I
I
I
I
I
BETA SECTOR
AZIMUTH 21 0'
~------A
I v-----
I
I
I
I
I
I
----
MICROWAVE DISH
AZIMUTH T.B.D. -
~-LAND DOES NOT INCLUDE RIGHTS
Of ACCESS TO OR FROM STREET
ABUTTING SAID LAND
EXISTING TELCO ROOM AT 1ST
FLOOR OF EXISTING BUILDING
(PROPOSED TELCO P.O.C.)
EXISTING
0 TWO STORY
BUILDING
PROPOSED 4"111 TELCO CONDUIT ABOVE __ .J
CEILING IN 1ST FLOOR CORRIDOR
(TELCO LENGTH = ±95' -01
PROPOSED ELECTRICAL CONDUITS------'
FOR GENERATOR ROUTING ABOVE
CEILING IN 1ST FLOOR CORRIDOR
----SALK AVENUE -------------
PROPOSED VERIZON WIRELESS 2'-0"11
r --1 MICROWAVE DISH ANTENNA MOUNTED
INSIDE A NEW ANTENNA TOWER
BEHIND RF TRANSPARENT SCREENS.
I APN: 212-130-050-00 I'---
' I
EXISTING DRIVEWAY
FOR INGRESS/EGRESS
SEE SHEET A-2 FOR r---1 EQUIPMENT FLOOR PLAN
---
N74'25'15"W
41.29'
-
A-55'55'30"
R~60.00'
L~58.56'
\
~~ I~ -\o 10 \~
I
\
I
\
I
\
I
)
I
I
I _____________________ JL __
SITE PLAN
PROPOSED \!ERIZON WIRELESS ANTENNAS
_..----1 MOUNTED INSIDE A NEW ANTENNA TOWER
BEHIND RF TRANSPARENT SCREENS.
PROPOSED \!ERIZON WIRELESS
~--1 EQUIPMENT ROOM ON 1ST FLOOR Of
EXISTING BUILDING (SHOWN SHADED)
.,---EXISTING ELECTRICAL ROOM AT 1ST
FLOOR OF EXISTING BUILDING
(PROPOSED ELECTRICAL P.O.C.)
-----
ALPHA SECTOR
AZIMUTH 90' •
EI\SEMENTS:
EASEMENTS SHOWN REFLECT PRELIMINARY RECORDS RESEARCH
OF RECORDED PARCEL IJ.APS & PRELIMINARY TITLE REPORT.
EASEMENTS ARE SUBJECT TO REVIEW Of FINAL TITLE REPORT.
SEE SHEET C-1 FOR ADDITIONAL INFORMATION ON NON
PLOTTABLE EASEMENTS
BOUNDARY NOTE:
THE PROPERTY BOUNDARY LINES SHOWN ON THIS DRAWING
ARE FOR REfERENCE ONLY. A BOUNDARY SUR\!EY WAS NOT
PERFORMED
A~CHITECTURE •• •• I NCOI\PO!l.IHED
:?1'25 CtULSDI1D VIllAGE DRIVE, SUITE P'l
C~RlSDAD. C~ 9~006 (760) 434-84,_
====================
PREPARED FOR
wireless
P.O. BOX 19707
IRVINE, CA 92623-9707
(949) 286-7000
======== :: ========
APPROVALS
A&C DATE
RE DATE
RF DATE
INT DATE
EE/IN DATE
OPS DATE
EE/OUT DATE
•• ••
PROJECT NAME
TAYLORMADE
5541 FERMI COURT
CARLSBAD, CA 92008
SAN DIEGO COUNTY
======== :: ========
03/27/13
04/16/13
04/19/13
04/22/13
04/25/13
06/17/13
DRAWING DATES
80% ZD (se)
90% ZD (se)
100% ZD (se)
1 A CERT. 100% ZD {rd)
OWNER REV. 100% ZD (rd)
PLANNING REV. 1 DO% ZD (rd)
======== :: ========
SHEET TITLE
SITE PLAN
============================
PROJECTS\ VERIZDN\ 13127
======== :: ========
A-0
• -------136~--'1 ..,
136.33' F.S.
4'-o•
------137--1-----------+----
'o
, 38,----~ -. +------
0 .;,
139~---~~~~---==~======~~~[Jl:~
I "N
147.83' T.O.W.
CLR •.
12'-0"
EXISTING
TRASH
ENCLOSURE
GAP
GENERATOR PLAN
SCALE: 114'•1'-G'
EXISTING
MECHANICAL
ENCLOSURE
(E) 136.97' F.S.
EXISTING
TRASH
ENCLOSURE
I
I
I
I
I
I
I
I
I
I L _____ _
\
\
\
GENERATOR PLAN NOTES:
PROPOSED VERIZON WIRELESS 30kw ENCLOSED EMERGENCY GENERATOR WITH
A 148 GALLON DOUBLE WALL SUBBASE FUEL TANK ON A POURED-IN-PLACE
CONCRETE PAD. "KOHLER" 30REOZJC-VER GENERATOR UNIT OR EQUIVALENT
SIZED UNIT WITH A SINGLE UNIT SOUND PRESSURE LEVEL OF 65 dBA AT A
REFERENCE DISTANCE OF 23 FEET.
PROPOSED CONCRETE CONTAINMENT CURB
PROPOSED CONCRETE BLOCK WALL ENCLOSURE.
FINISH AND PAINT TO MATCH EXISTING MECHANICAL ENCLOSURE.
PROPOSED ciNDERGROUND ELECTRICAL CONDUIT TRENCH
PROPOSED CHAINUNK LID
PROPOSED 3' -0" WIDE STEEL GATE W/ FRAME & SIGNAGE
INSTALL 3" LAYER OF 3/ 4" CRUSHED GRAVEL OVER FIBER
GROWTH BARRIER WITHIN ENTIRE EQUIPMENT COMPOUND
PROPOSED CONCRETE LANDING
PROPOSED 36" X 48" LOUVERED VENT WITH 12" THICK
ACOUSTIC LOUVERS OR UNIT WITH SIMILAR OR GREAT:ER
NOISE CONTROL CAPABILITIES
PROPOSED FUEXIBLE DUCT
PROPOSED CRIB WALL
EXISTING CONCRETE SIDEWALK
EXISTING LANDSCAPE AREA
EXISTING CONCRETE CURB
EXISTING ASPHALT PAVED PARKING LOT
EXISTING RETAINING SCREEN WALL
EXISTING PAIR CHAIN LINK GAllES
EXISTING PAIR STEEL TRASH ENCLOSURE GAllES
EXISTING CONCRETE TRASH ENCLOSURE WALL
EXISTING CONCRETE PAD
PROPOSED KNOX BOX
PROPOSED EXTERNAL POWER SHUT-OFF FOR THE GENERATOR.
FUSED DISCONNECT SWITCH UNISTRUT MOUNTED TO WALL
PROVIDE AND INSTALL (1) WALL MOUNTED CLASS "ABC" FIRE EXTINGUISHER
INSIDE A NEMA 3R CABINET
PROPOSED GENERATOR SIGN WITH NFPA 704 PLACARD
MOUNTED TO STEEL GATE
ARCHITECTURE •• •• INCORPORATED
3~5 CARLSBAD VILLAGE DRIVE, SUITED~
CAHSDAD. CA 9~006 (760) 4 H-5 474
=============== ==============
PREPARED FOR
• vertlR_ftwireless
P .0. BOX 19707
IRVINE, CA 92623-9707
(949) 286-7000
=============== ==============
APPROVALS
A&C DATE
RE DATE
RF DATE
INT DATE
EE/IN DATE
OPS DATE
EE/OUT DATE
•• ••
PROJECT NAME
TAYLORMADE
5541 FERMI COURT
CARLSBAD, CA 92008
SAN DIEGO COUNTY
======================
03/27/13
04/16/13
04/19/13
04/22/13
04/25/13
06/17/13
DRAWING DATES
80% ZD (so)
90% ZD (ss)
100% ZD (se)
1 A CERT. 100% ZD (rd)
OWNER REV. 1 00% ZD (rd)
PLANNING REV. 100% ZD (rd)
==============:: ==============
SHEET TITLE
GENERATOR PLAN
============== :: =============
PROJECTS\ VERIZON\ 131 27
=========================
A-1
EXISTING
1ST FLOOR
EXIT CORRIDOR
r-_
I ' I I
I I I I I
PROPOSED \IERIZON ---.,.
WIRELESS EQUIPMENT
ROOI.t (B-OCCUPANcv) I I --~[~ /
EXISTING
TENANT SPACE
(B-OCCUPANcv)
To• c -7·
I
I
I
l
I
I
I
I
-._J
----------
1
EXISTING
TENANT SPACE
SUITE 1508
(B-OCCUPANCY)
EQUIPMENT FLOOR PLAN
9CALE: :w". 1'-o'
------
----
EXISTING
TENANT SPACE
(B-OCCUPANcv)
" ~ -------4------~~
~-----
---------
------
----
--
-----
--/ ----_ ...... ----
......____
)
/
I
I
I
/
-~·-·---...... -
-...._.
NOTE: ADD SIGNAGE TO THE VERIZON EQUIPMENT ROOM WHICH SHALL
STATE THE fOLLOWING:
1. THE ROOM CONTAINS ENERGIZED BATTERY SYSTEMS.
2. THE ROOM CONTAINS ENERGIZED ELECTRICAL CIRCUITS.
3. THE BATIERY ELECTROLYTE SOLUTIONS, WHERE PRESENT, ARE
CORROSIVE LIQUIDS
EQUIPMENT FLOOR PLAN NOTES:
PROPOSED \IERIZON WIRELESS TELECOMMUNICATIONS EQUIPMENT INSIDE A NEW
EQUIPMENT ROOM ON 1ST fLOOR Of EXISTING BUILDING
PROPOSED \IERIZON WIRELESS NORTEL COMA EQUIPMENT RADIO RACK (RR)
29" WIDE K 64" HIGH K 25" DEEP. WEIGHT: 1200 LBS.
0 PROPOSED VERIZON WIRELESS NORTEL COMA EQUIPMENT RACK (DR)
29" WIDE K 64" HIGH x 25" DEEP. WEIGHT: 1000 LBS.
PROPOSED \IERIZON WIRELESS PCS EQUIPMENT RACK (DR)
29" WIDE x 84" HIGH x 25" DEEP. WEIGHT: 1000 LBS.
<$ PROPOSED \IERIZON WIRELESS BATTERY RACK, (TYPICAL OF 2)
27-5/B" WIDE x 57" HIGH x 22-1/2" DEEP. WEIGHT: 2918 LBS.
PROPOSED \IERIZON WIRELESS TOLL RACK.
24" WIDE x 57" HIGH x 15" DEEP. WEIGHT: 500 LBS.
PROPOSED AIR HAINDLERS
PROPOSED FUSED DISCONNECT SWITCH MOUNTED TO WALL
PROPOSED AUTOMATIC TRANSFER SWITCH MOUNTED TO WAILL
PROPOSED MANUAL TRANSFER SWITCH MOUNTED TO WAILL
PROPOSED 200 AMP ELECTRICAL PANEL MOUNTED TO WALL
PROPOSED MAIN GROUND BUS BAR TO BE MOUNTED TO WALL
PROPOSED 3' -0" WIDE STEEL DOOR AND FRAME & VERIZON WIREU::SS SIGNAGE
PROPOSED ALUMINUM THRESHOLD
PROPOSED OVERHEAD 18" CABLE LADDER 0 +7'-6" (SHOWN DASHED)
PROPOSED SURFACE MOUNTED FLORESCENT LIGHT FIXTURES (TYPICAL Of 4)
PROPOSED WALL MOUNTED TELCO BOARD
PROPOSED 12" x 12" x 1/8" VINYL FLOOR TILES. EXCELON #51973 MONO
WHITE WITH 4" COVER BASE
PROVIDE AND INSTAUL (1) WAILL MOUNTED CLASS "ABC" fiRE EXTINGUISHER
PROVIDE AND INSTAUL (1) BATIERY ACID SPILL KIT
PROPOSED VERIZON WIRELESS REVERSE SERVICE GENERATOR RECEPTACLE
FOR EMERGENCY GENERATOR CONNECTION MOUNTED TO WAILL
PROPOSED REFRIGERANT LINE ROUTING ABOVE CEILING IN CORRIDOR
PROPOSED TELCO CONDUIT ROUTE ABOVE CEILING IN CORRIDOR
PROPOSED ELECTRICAL CONDUIT ROUTE ABOVE CEILING
PROPOSED (6) 6"111 CONDUITS FOR COAX CABLE &
(1) 1-1/2"111 CONDUIT FOR GROUND
PROPOSED COAXIAL CABLE ROUTE ABOVE CEILING IN CORRIDOR
(SHOWN DASHED)
PROPOSED COAX CABLE CONDUIT AND REf UNE PENETRATIONS
THRU fLOOR ABOVE (TYPICAIL)
PROPOSED METAL STUD WALL (SHOWN SHADED)
EXISTING METAL STUD WAUL (TYPICAIL)
EXISTING CONCRETE EXTERIOR WAILL
EXISTINIG EXTERIOR DOOR (TYPICAL)
EXISTING WINDOW (TYPICAL)
EXISTING INTERIOR DOOR
EXISTING ELECTRICAL TRANSFORMER
EXISTING SWITCHGEAR INSIDE ELECTRICAL ROOM
AT FIRST FLOOR OF EXISTING BUILDING
EXISTING 2000A, 277/480V, 3-. 4W PUUL SECTION
(PROPOSED ELECTRICAL P .D.C.)
PROPOSED \IERIZON WIRELESS ELECTRICAL METER OPTION "A"
USE EXISTING 200A, 277/480V SPARE METER SOCKET
(ONLY NEED 100 AMP)
PROPOSED VERIZON WIRELESS ELECTRICAL METER OPTION "B"
1 00 AMP, 277/480V ELECTRICAIL METER MOUNTED TO WALL
PROPOSED ELECTRICAL CONDUITS FOR GENERATOR ROUTING
ABOVE CEILING IN CORRIDOR
EXISTING CONCRETE GUTIER
EXISTING CONCRETE CURB
EXISTIN'G CONCRETE SIDEWALK
EXISTING LANDSCAPE AREA
EXISTING IRRIGATION CONTROL BOX
EXISTING UTILITY VAULT
EXISTING FIRE HYDRANT
EXISTING ASPHALT PAVED PARKING LOT
PROPOSED STEP-DOWN TRANSFORMER
EXISTING TIMER CLOCK RELAY BYPASS PANEL
EXISTING ELECTRICAL DISTRIBUTION PANELS
EXISTING BUSSED GUTIER (SHOWN DASHED)
PROPOSED 8ATIERY "CAUTION" SIGN ON DOOR.
NFPA 704 PLACARD SHAILL BE APPLIED ON THE FRONT Of THE STRUCTURE OR
EACH ACCESS TO A ROOM OR AREA. THE PLACARD SHAUL IDENTIFY THE
HAZARDS OF HEAILTH, fLAMMABIUTY AND INSTABIUTY PER NFPA 704. A SIGN
IDENTIFYING THE ELECTRICAIL POWER SHUTOFF SHALL BE POSTED TO THE
SATISFACTION Of THE FIRE DEPARTMENT. EMERGENCY CONTACT INFORMATION
SHAUL BE LABELED ON THE EQUIPMENT ROOM DOOR
BATTERY SUMMARY
BATTERY RACK:
(24) NORTH STAR NSB 170 FT (VRLA)
AT 131.2 LBS PER BATIERY
24 x 131.2 LBS
TOTAL BATTERY WEIGHT = 3148.8 LBS
PER MATERIAL SAFETY DATA SHEET
ELECTROLYTE (SULFURIC ACID) ~ 17:!:
WEIGHT PER 8ATIERY x 17%
TOTAL SUUFURIC ACID = 535.30 LBS
GALLONS TO POUNDS
1 US GAIL = 10.66 LBS
TOTAL GALLONS = 50.22 GALLONS
OF SULFURIC ACID
SUMMARY:
+ 50.22 GAULONS > 50 GAILLONS
+ THIS SITE MUST COMPLY WITH THE
REQUIREMENTS SET FORTH IN SECTION
608 OF THE CALIFORNIA FIRE CODE.
(EXCEEDS 50 GAIL MAXIMUM)
+ 50.22 GAULONS < 55 GAILLONS
• COUNTY Of SAN DIEGO HAZMAT
BUSINESS PLAN IS NOT REQUIRED
ARCHITECTURE •• .. INCORPORATED
3~5 CARlSBAD ~ILLAGE DRIVE. SUITE D2
CARLSBAD, CA 9200a (760) 434·8474
======== :: ========
PREPARED FOR
P.O. BOX 19707
IRVINE, CA 92623-9707
(949) 286-7000
======== :: ========
APPROVALS
A&C DATE
RE DATE
RF DATE
INT DATE
EE/IN DATE
OPS
EE/OUT
DATE
DATE
•• ••
PROJECT NAME
TAYLORMADE
5541 FERMI COURT
CARLSBAD, CA 92008
SAN DIEGO COUNTY
======== :: ========
03/27/13
04/16/13
04/19/13
04/22/13
04/25/13
06/17/13
DRAWING DATES
80% ZD (se)
90% ZD (se)
100% ZD (se)
1,6. CERT. 100% ZO (rd)
OWNER REV. 100% ZD (rd)
PLANNING REV. 100% ZD (rd)
======== :: ========
SHEET TITLE
EQUIPMENT
FLOOR PLAN
======== :: ========
PROJECTS\ VERIZON\ 13127
··==== ••
A-2
,I
BETA SECTOR
AZIMUTH 21 0'
GAMMA SECTOR
AZIMUTH 330' •
MICROWAVE DISH
AZIMUTH T.B.O. -
-------------........ ' \
I
I
I
I
I
ROOF PLAN
~--ISEE SHEET A-4 FOR
-" ANTENNA PLAN A
-------~ -~
•
ROOF PLAN NOTES:
PROPOSED COAX CABLE CONDUIT AND REF LINE ROUTING
FROM FLOOR BELOW (TYPICAL)
PROPOSED COAXIAL CABLE ROUTE SUSPENDED
UNDER ROOF ASSEMBLY BELOW (SHOWN DASHED)
PROPOSED REFRIGERANT UNE ROUTING SUSPENDED
UNDER ROOF ASSEMBLY BELOW 0 PROPOSED "TRAF-WALK" PADS
<$> EXISTING LOW PARAPET WALL
<§> EXISTING HIGH PARAPET WALL
0 EXISTING UPPER PARAPET WALL
~ EXISl'ING BUILT-UP ROOF
0 EXISTING ROOF ACCESS HATCH
q} EXISl'ING ROOF DRAIN
~ EXISTING VENT
~1;.
I
I
/ ...-
...---ISEE SHEET A-4 FOR
ANTENNA PLAN 8
ALPHA SECTOR
AZIMUTH 90' ..
PROPOSED VERIZON WIRELESS ANTENNAS
MOUNTED INSIDE A NEW ANTENNA TOWER
BEHIND RF TRANSPARENT SCREENS.
ARCHITECTURE •• •• INCORPORATED
325 CARLSBA~ VIllAGE D~IVE. SUITE ~2
CARLSCA~. CA 92008 (760) H ~-BV4
================
PREPARED FOR
wireless
P.O. BOX 19707
IRVINE, CA 92625-9707
(949) 286-7000
==========:: =============
APPROVALS
A&C DATE
RE DATE
RF DATE
INT DATE
EE/IN DATE
OPS
EE/OUT
DATE
DATE
•• ••
PROJECT NAME
TAYLORMADE
5541 FERMI COURT
CARLSBAD, CA 92008
SAN DIEGO COUNTY
=============================
03/27/13
04/15/13
04/19/13
04/22/13
04/25/13
06/17/13
DRAWING DATES
80% ZD (sa)
90% ZD (so)
100% ZD (se)
1 A CERT. 100% ZD (rd)
OWNER REV. 100% ZD (rd)
PLANNING REV. 100% ZD (rd)
======== == =======
SHEET TITLE
ROOF PLAN
============== ============
PROJECTS\ VERIZON\ 13127
================ =============
A-3
SECTOR G1 -G4
AZIMUTH 330"
\
\
'
•
• .... o ,'J.
\
\
\
\
\
\
\
I
SECTOR B1-B4
AZIMUTH 21 0"
\
\
' \
\
\
\
\
\
I ...
I I
4'-o ..
I
I
I
I
I
I
I
I
I
I
I
I
I
MICROWAVE DISH
AZIMUTH T.B.D. -
I
I
I
,,, ,, I .....
I
ANTENNA PLAN A
BCALE: w·-1'-cr
ANTENNA AND COAXIAL CABLE SCHEDULE
SECTOR DIRECTION AZIMUTH ANJ'ENNA MODEL NUMBER DDWmlLT SKEW SIZE
ANTENNA ANGUE
ALPHA1 COMMSCOPE: SBNH-10656511 50.91' L X 11.85' w • 7.1' D
ALPHA2 M' L x 12' W x B' D ERICSSON: />JR
ALPHI\.3 EAST 90' COUMSCOPE: SBNH-10656511 r:t N/A 50.91' LX 11.85' w • 7.1' D
ALPHM CDMMSCOPE: SBNH-10656511 50.91' L x 11.85' W x 7.1' D
SETAl COMMSCO?E: SBNH-1 0656511 50.91' L x 11.85' W x 7.1" D
BETA2 ERICSSON: />JR 54' L x 12' W x 8' D
SOUTHWES 210' 0' N/A BETA3 COMMSCOPE: SBNH-10656511 50.91' l x 11.85' W x 7.1' D
BETM COMMSCOPE: SBNH-1 0656511 50.91' L x 11.85' W x 7.1" D
GAMMA1 COMMSCOPE: S8NH-1D6565A 50.91' L K 11.85' w • 7.1" D
GAMt.IA2 ERICSSON: />JR M' l x 12' W x 8' D N/A NORTHWEST 330' r:t 50.91' L K 11.65' w. 7.1' D GAMUA3 COIAMSCOPE: SBNH-1 0656511
GAMMA4 COIAMSCOPE: SBNH-106565A 50.91' l x 11.85" W x 7.1" D
MICROWAVE DISH T.B.D. T.B.D. --2' o· OIAUETER
~0
NUUBER COAX. ~LE JUMPER COAX SIZE
OF CABLES UENGTH UENGTH
PER SECTOR (+ I -s') (+ I -3')
B COAX
+ 7/B' FIBER 12s·-o· e·-o·
(T.B.D.)
B COAX
+ 365'-0' s·-o· 1 5/8' FIBER
(T.B.D.)
B COAX
+ FIBER 370'-0' s·-o· 1 5/8"
(T.B.D.)
1 375'-o· -1 1/4'
~0
ANTENNA PLAN B
9CftLE: 114"•1'-G"
ANTENNA PLAN NOTES:
~
<:9
0 ~
PROPOSED VERIZON WIRELESS ANTENNAS MOUNTED INSIDE
NEW ANTENNA TOWER BEHIND RF TRANSPARENT SCREENS
PROPOSED VERIZON WIRELESS RRU MOUNTED BEHIND
ANTENNA INSIDE NEW ANTENNA TOWER
PROPOSED UNISTRUT
PROPOSED VERIZON WIRELESS 2' -0'111 MICROWAVE DISH
ANTENNA MOUNTED INSIDE NEW ANTENNA TOWER BEHIND
RF TRANSPARENT SCREENS.
PROPOSED RF TRANSPARENT SCREEN
4 x 4 RF TRANSPARENT FIBERGLASS TUBE FRAMING
4 x 4 RF TRANSPARENT DIAGONAL BRACE
4 x 4 RF TRANSPARENT ANGLE BRACING ABOVE
(SHOWN DASHED)
,, ,,,
I
0
~
~ q}
PROPOSED VERIZON WIRELESS E/911 GPS ANTENNAS MOUNTED
TO PROPOSED BRACE (TYPICAL OF 2)
4}
~
PROPOSED s"• NON-COMBUSTIBLE SLEEVES AT
ROOF PENETRATION (SHOWN DASHED)
PROPOSED 24" x 24" COAX CABLE HATCH
PROPOSED COAX CABLE TRAY ON 4 x 4 PVC SLEEPERS
PROPOSED COAXIAL CABLE ROUTE SUSPENDED
UNDER ROOF ASSEMBLY BELOW (SHOWN DASHED)
PROPOSED REFRIGERANT LINE ROUTING SUSPENDED
UNDER ROOF ASSEMBLY BELOW
I
I
I
I
' 0 I ·v
• 0 I
'=.t
' 0 I '=.t
PROPOSED PITCH POCKET
PROPOSED MECHANICAL UNITS ON PVC SLEEPERS (TYPICAL OF 2).
"CARRIER" AIR CONDITIONING UNITS MODEL 38HDR060 OR
EQUIVALENT SIZED UNITS.
PROPOSED REFRIGERANT LINES ON PVC SLEEPERS
PROPOSED "TRAF -WALK' PADS
EXISTING LOW PARAPET WALL
EXISTING HIGH PARAPET WALL
EXISTING BUILT -UP ROOF
EXISTING ROOF DRAIN
SECTOR A 1 -A4
• AZIMUTH 90" 0 I • 0.
~
ii~CHITECTU~E •• •• I NCORPOR!ITEP
325 c•~LSD"D Vlll.GE D~IVE. SUITE D2
CARLSDAD, CA 9~008 (760) 434-8474
========n========
PREPARED FOR
P.O. BOX 19707
IRVINE, CA 92623-9707
(949) 286-7000
•• ••
APPROVALS
A&C DATE
RE DATE
RF DATE
INT DATE
EE/IN DATE
OPS DATE
EE/OUT DATE
•• ••
PROJECT NAME
TAYLORMADE
5541 FERMI COURT
CARLSBAD, CA 92008
SAN DIEGO COUNTY
=============== :: ==========
03/27/13
04/16/13
04/19/13
04/22/13
04/25/13
06/17/13
DRAWING DATES
BO% ZD (so)
90% ZD (se)
100% ZD (se)
1 A CERT. 100% ZD (rd)
OWNER REV. 1 00" ZD (rd)
PLANNING REV. 1 00" ZD (rd)
=============:: =========
SHEET TITLE
ANTENNA PLANS
=============== :: ==============
PROJECTS\ VERIZON\ 13127
====================
A-4
PROPOSED VERIZON WIRELESS ANTENNAS
MOUNTED INSIDE A NEW ANTENNA TOWER
BEHIND RF TRANSPARENT SCREENS.
, 139. 76' F.F.
• It)
I
Co "'
·~
• 'l'
"' "'
"" '"' F.G.
IIl I'='-w
' !
!
SOUTH ELEVATION
SCALE: IJNif • I • -11'
fl:
1'/ ', ·, ~
\~ ~
139.63' F.S.
PROPOSED VERIZON WIRELESS ANTENNAS
~--. MOUNTED INSIDE A NEW ANTENNA TOWER
BEHIND RF TRANSPARENT SCREENS.
·~
~ A., LOW PARAP ..... • ~.· .l'.' .· i.~1.J,J i.~ 1--_ _j_ _ ----"<" (NEW)'-1' ~ 171.68' T.O.P. --'k---f:=========~:'-.t-__ ..::_V_:~-----~~-~..----_:~_~i--= ___ ~ ~J,_ --ll.J.,::"~~;.~a.J-
(HIGH PARAPET) -- ------~ ... --··· ---II -----~-~~ -_-_:__!' "M
1 39.76'
F.F.
• ":
139.29' F.G.
Ea. 1-,--,.--~ ~ , m m
'
I
.
I
!
I
I I \ i I il
j l \ \ ;' I
~~ 13~. I ~
EAST ELEVATION
SCALE: IJNif. ,._,.
.11--0
l---<5
• • 1{)1
co, ~ ~
\ .' '-------'-"13""8.:§"96~' ~~ ~
F.G. '-/"
139.76' F.F.~
\
~
-<9 ~
II-
.
I I
I
II
I \,
\
\ \ \
'4 ~ -0 ~
ELEVATION NOTES:
0 PROPOSED VERIZON WIRELESS ANTENNAS MOUNTED INSIDE
NEW ANTENINA TOWER BEHIND RF TRANSPARENT SCREENS
CENTERUNE OF VERIZON WIRELESS ANTENNAS
PROPOSED RF TRANSPARENT SCREEN ANTENNA TOWER
(SHOWN SHADED)
EXISTING PORTION OF UPPER PARAPET TO BE REMOVED
FOR RF TRANSPARENT SCREEN (SHOWN DASHED)
EXISTING CONCRETE BUILDING WALL
EXISTING RIEVEAL (1YPICAL)
EXISTING INSET TILE (1YPICAL)
EXISTING STOREFRONT DOOR (1YPICAL)
EXISTING STOREFRONT WINDOW (1YPICAL)
EXISTING W'INDOW (1YPICAL)
EXISTING GIRADE
EXISTING RrOOF SURFACE (SHOWN DASHED)
• ~
~
I .
~ "'
r 139.76' ~
\ F.F. '-/"
1 ~" ~"·
F. G.'
ARCHITECTURE •• •• INCORPORATED
325 CARLSDAD VILLAGE DkiVE, SUITE D2
CARLSDAD, CA 92006 (760) •H·&•7•
=============:: ==============
PREPARED FOR
P .0. BOX 1 9707
IRVINE, CA 92623-9707
(949) 286-7000
.. ..
APPROVALS
A&C DATE
RE DATE
RF DATE
INT DATE
EE/IN DATE
OPS DATE
EE/OUT DATE
•• ..
PROJECT NAME
TAYLORMADE
5541 FERMI COURT
CARLSBAD, CA 92008
SAN DIEGO COUNTY
============================
03/27/13
04/1 S/13
04/19/13
04/22/13
04/25/13
06/17/13
DRAWING DATES
80% ZD (se)
90% ZD (se)
100% ZD (se)
1 A CERT. 100% ZD (rd)
OWNER REV. 1 00% ZD (rd)
PlANNING REV. 100% lD (rd)
================ =============
SHEET TITLE
EXTERIOR
ELEVATIONS
==============:: =============
PROJECTS\ VERIZON\ 13127
==============:: =============
A-5
'F.F.
• ~
~
I . -"'
• 1 38.96'
1 F.G.
'lo ' ;.,.174. ~ T.O.P.
H -~
~ -I
I
I I i
<$-~ ~ ~ <9-
NORTH ELEVATION
PROPOSED VERIZON WIREllSS ANTENNAS
MOUNTED INSIDE A NEW ANTENNA TOWER 1----,
BEHIND RF TRANSPARENT SCREENS.
rlo.139.76' F.F.
V r • 00 I . -
'F.G.
I-~---
WEST ELEVATION
8CAU!: 1132" •1'-G"
// '..__
f ~,. ~'
~ <b--1
J31M5' f.S.
H H
PROPOSED VERIZON WIRELESS 2' -0"16
MICROWAVE DISH ANTENNA MOUNTED
INSIDE A NEW ANTENNA TOWER
BEHIND RF TRANSPARENT SCREENS.
~
A:-,
'"' ro I I ·..,
I')
I') "'
''" "' F.G.
ELEVATION NOTES:
¢ PROPOSED VERIZON WIRELESS ANTENNAS MOUNTED INSIDE
NEW ANTENNA TOWER BEHIND RF TRANSPARENT SCREENS
CENTERUNIE OF VERIZON WIRELESS ANTENNAS
PROPOSED RF TRANSPARENT SCREEN ANTENNA TOWER
(SHOWN SHADED) <9 EXISTING PORTION OF UPPER PARAPET TO BE REMOVED
FOR RF TRANSPARENT SCREEN (SHOWN DASHED)
~ EXISTING CONCRETE BUILDING WALL
~ EXISTING REVEAL (lYPICAL)
0 EXISTING INSET TILE (1YPICAL)
~ EXISTING STOREFRONT DOOR (lYPICAL)
~ EXISTING STOREFRONT WINDOW (lYPICAL)
~ EXISTING WINDOW (lYPICAL)
~ EXISTING GRADE
~ EXISTING ROOF SURFACE (SHOWN DASHED)
1~0 7R' F.F . .J-...
'-f'
)
~
ARCHITECTURE •• •• I NCORPORI1TED
3125 CARLSBtH> VILLI1GE Dll.IVE, SUITE 1>2
CARLSDAD. CA 92008 (760) ~J~·5474
========================
PREPARED FOR
wireless
P.O. BOX 19707
IRVINE, CA 92623-9707
(949) 286-7000
.. ••
APPROVALS
A&C DATE
RE DATE
RF DATE
INT DATE
EE/IN DATE
OPS DATE
EE/OUT DATE
•• ..
PROJECT NAME
TAYLORMADE
5541 FERMI COURT
CARLSBAD, CA 92008
SAN DIEGO COUNTY
============================
03/27/13
04/1 5/13
04/19/13
04/22/13
04/25/13
06/17/13
DRAWING DATES
80% ZD (se)
90% ZD (se)
100% ZD (se}
1 A CERT. 1 DO% ZD (rd)
OWNER REV. 1 DO% ZD (rd)
PLANNING REV. 100% ZD (rd)
====================
SHEET TITLE
EXTERIOR
ELEVATIONS
============================
PROJECTS\ VERIZON\ 13127
============================
A-6
-----
NORTH ELEVATION
;.~·';>\:
-,( 1; ,1;
• ..::._ ,;>1 ' I
' " \: '~
'' ::··;/~:;··)(~ ~
I
I
-____ _:::~L-------------~=:====~~==~==:::::::::=:::::="~::"~~::-= c--
_____ L_ __ _
8
WEST ELEVATION
8CH.E: 114". 1'4'
I • I I I I 1 --1--_j _ _J
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I _ _j
/ (
I , __
7
147 .83' T.O.W.
• 'f ·,
~::J ___ _j -------------~--''k---'1"'36,.,.,33.,_'_,F~.s,.,.I"W-
• .... I ;,
~ 147.83' r.o.w.$ "
'"' I .
~ -
GENERATOR ELEVATION NOTES:
0 PROPOSED VERIZON WIRELESS ENCLOSED EMERGENCY
GENERATOR ON A POURED-IN-PLACE CONCRETE PAD
(SHOWN DASHED)
PROPOSED CONCRETE BLOCK WALL ENCLOSURE.
FINISH AND PAINT TO MATCH EXISTING MECHANICAL ENCLOSURE
PROPOSED 3'-0" WIDE STEEL GATE W/ FRAME & SIGNAGE
PROPOSED REVEAL TO MATCH EXISTING (TYPICAL)
PROPOSED INSET TILE TO MATCH EXISTING (TYPICAL)
PROPOSED 36" X 4B" LOUVERED VENT WITH 12" THICK
ACOUSTIC LOWERS OR UNIT WITH SIMILAR OR GREATER
NOISE CONTROL CAPABIUTIES
PROPOSED CRIB WALL
PROPOSED CONCRETE LANDING
EXISTING CONCRETE MECHANICAL ENCLOSURE
EXISTING REVEAL (TYPICAL)
EXISTING TILE INSET (TYPICAL)
EXISTING CHAINLINI< LID
EXISTING CONCRETE SIDEWALK
EXISTING CONCRETE PAD
EXISTING CONCRETE CURB
EXISTING ASPHALT PAVED PARKING LOT
EXISTING RETAINING SCREEN WALL
EXISTING PAIR snEEL TRASH ENCLOSURE GATES
EXISTING CONCRETE TRASH ENCLOSURE WALL
EXISTING LANDSCAPE AREA
EXISTING GRADE
PROPOSED KNOX BOX
PROPOSED EXTERNAL POWER SHUT -OFF FOR THE GENERATOR.
FUSED DISCONNECT SWITCH UNISTRUT MOUNTED TO WALL.
PROPOSED GENERATOR SIGN NFPA 704 PLACARD MOUNTED TO STEEL GATE
ARCHITECTURE •• .. I NCORWRI1TED
325 CII~LSB~D VILLAGE D~IVE. SUITE D2
CA~LSOAD. CA 92008 (760) 434-8H4
================= ===============
PREPARED FOR
wireless
P.O. BOX 19707
IRVINE, CA 92623-9707
(949) 286-7000
=============== :: ===============
APPROVALS
A&C DATE
RE DATE
RF DATE
INT DATE
EE/IN DATE
OPS DATE
EE/OUT DATE
•• ••
PROJECT NAME
TAYLORMADE
5541 FERMI COURT
CARLSBAD, CA 92008
SAN DIEGO COUNTY
================================
03/27/13
04/16/13
04/19/13
04/22/13
04/25/13
06/17/13
DRAWING DATES
80% ZD (se)
90% ZD (se)
100% ZD (se)
1 A CERT. I 00% ZD (rd)
OWNER REV. 1 DO" ZD (rd)
PLANNING REV. 100% ZD (rd)
===============================
SHEET TITLE
GENERATOR
ENCLOSURE
ELEVATIONS
=============== == ==============
PROJECTS\ VERIZOI'I\ 13127
==========================
A-7
SCALE:
I
1 "
I
I
I
I
;v~ I
tj
II -..II
I
I
I
/51 'l.
,:r ....
d!:l
I
I
I
-~~~ ~ • 0)
JJ I
I
·vi /~
.& ~I ~I
I
I
..... ,'\'33"
S).J oo· ,.r ,..'),.~· 66 • v~ t..O·
?--""
COORDINATES: +
Alpha Sector
LATITUDE:
LONGITUDE:
Beta
33"08'31.74" N
1 17'16'55.02" w + Gamma
LATITUDE: 33'08'32.49" N
LONGITUDE: 1 1 7' 1 6'57.70" W
<CCESS
HATCH
--------------7~
---- ----- ----- -331.57''--' ------------....., __ N-8T34'17"E
LEGEND:
CL -CENTER LINE
Dl -DRAIN INLET
E. -EAST
EP -EUECTRIC PULLBOX
FF -FINISH FLOOR
FG -FINISH GRADE
FH -FIRE HYDRANT
FS -FINISHED SURFACE
ICB -IRRIGATION CONTROL BOX
N. -NORTH
NE. -NORTHEAST
NG -NA TIURAL GROUND
NW. -NORTHWEST
PO -POST
RS -ROOF SURF ACE
S. -SOUTH
SCO -SEWER CUEANOUT
SDMH -STORM DRAIN MANHOLE
SE. -SOUTHEAST
SLPB -STREET LIGHT PULLBOX
SW. -SOUTI-IWEST
TC -TOP OF CURB
T.O.W. -TOP OF WALL
TP -TOP OF PARAPET
TR -TREE
UV -UTILITY VAULT
VIN -VENT
W. -WEST
YN-WATER VALVE
DATUM STATEMENT:
BASIS OF BEARINGS:
PARCEL 1
PARCEL MAP NO. 17830
BASIS OF BEARINGS FOR THIS SURVEY IS THE CALIFORNIA COORDINATE SYSTEM
ZONE 6, NAD 83, EPOCH 2010.00, AS DERIVED LOCALLY THROUGH STATIC GPS
OBSERVATIONS CONSTRAINED TO THE FOLLOWING"CGPS" "CORS" NETWORK STA TlONS:
"P472" AND "P482"
BENCHMARK:
BENCHMARK FOR TI-llS SURVEY IS TI-lE GEOID 12A ORTI-IOMETRIC ELEVA TlON AT
"CGPS" "CORS" NEWTWORK STATION, BEING CALCULATED AT 566.83.
DATIUM: NAVDBB
Sectors
---
BOUNDARY NOTE:
THE BOUNDARY SHOWN HEREON IS BASED ON RECORD
INFORMATION AS COLLECTED FROM TI-lE ASSESSORS PARCEL
MAP, IT IS NOT THE RESULT OF A COMPLETE BOUNDARY
SURVEY, IT HAS BEEN PROVIDED FOR INFORMATIONAL
PURPOSES ONLY.
LINE TABLE
LINE
L1
L2
L3
L4
L5
L6
L7
LB
--
BEARI'JG LENGTH
N 00'02' 23"E 241 .25'
571'03' 38"E 85.97'
518'56'22"W 64.50'
N71'03' 3B"W 8.50'
518'56'22"W 18.12'
571'03' 38"E 8.50'
51 8'56'22"W 145.16'
N74'25'1 3"W 7.84'
l-3o.o'-l
.... I 11.&.1
I~ .... ~I .... I ....
I
I
_.j
'C-.! --~·p
8 'C-JZ
It)
-.i-
1")
LS. NO. 6379
Dlf
0 n co
I'
n· 0
_jZ w u()_
~x:<t:
<{::?'
()__j
w u
IY <{
()_
ITEMS CORRESPONDING TO SCHEDULE "B":
BY: FIDELITY NATIONAL TilLE COMPANY
1300 DOVE SffiEET, STE. 310
NEIWORT BEACH, CA 92660
(949) 622-5000
COMMITMENT NO.: 997-23022260-PP2
TilLE OFFICER: PATTI PORTER
DATED: FEBRUARY 27, 2013
THE FDLLO'MNG ITEMS IOERE FOUND IN SAID COMMITMENT AND ARE REFERENCED ON THIS MAP.
COVENANTS AND AGREEMENTS LISTED HEREON CONTAIN NUMEROUS ITEMS THAT AFFECT THE
SUBJECT PROPERTY, CONTENTS SHOULD BE REVIE\OED TO DISCERN SPECIFICS
r:%\_ THE HEREIN DESCRIBED PROPERTY LIES WITHIN THE BOUNDARIES OF A MELLO-RODS COMMUNITY
~ FA<CILITIES OISffiiCT (CFO) AS FOLLOWS, RECORDING DATE DECEt.IBER 19, 1990, RECORDING NO.:
90-0674118, OFFICIAL RECORDS. A NOTICE OF SPECIAL TAX LIEN WAS RECORDED MAY 20, 1991,
AS FILE NO. 91 -0236959 OF OFFICIAL RECORDS. THIS ITEt.l AFFECTS THE SUBJECT PROPERTY,
BLANKET IN NATURE AND IS NOT PLOTTIED HEREON.
It;\_ MATTERS CONTAINED IN THAT CERTAIN DOCUMENT, ENTilLED A HOLD HARt.IUESS AGREEt.IENT,
~ RE<CORDING DATE NOVEI.IBER 3, 1986, RECORDING NO: 86-501526, OFFICIAL RECORDS. THIS ITEII
AFFECTS THE SUBJECT PROPERTY, BLANKET IN NATURE AND IS NOT PLOTTED HEREON.
(";\_ COVENANTS, CONDITIONS AND RESlRICTIONS, RECORDING DATE: JUNE 29, 1988 RECORDING NO:
~ 88-313420, RECORDING DATE: AUGUST 8, 1988 RECORDING NO: 88-387706, RECORDING DATE:
DECEMBER 8, 1992, RECORDING NO: 92-0786590, RECORDING DATE: JUNE 1, 1995, RECORDING
NO' 95-0230848, RECORDING DATE: SEPTEMBER 18, 2001, RECORDING NO: 2001-0671492,
RE<CORDING DATE: FEBRUARY 8, 2012 RECORDING NO: 2012-0073464, OFFICIAL RECORDS. THIS
ITE~ AFFECTS THE SUBJECT PROPERTY, BLANKET IN NATURE AND IS NOT PLOTTIED HEREON.
®--MATTERS CONTAINED IN THAT CERTAIN DOCUMENT, ENTilLED A HOLD HARMLESS AGREEMENT,
RECORDING DATE: MAY 6, 1991 RECORDING NO: 91-0208521, OFFICIAL RECORDS. THIS ITEM
AFFECTS THE SUBJECT PROPERTY, BLANKET IN NATURE AND IS NOT PLOTTED HEREON.
®-AN AGREEMENT BE1WOEN OWNER, DEVELOPER AND THE CITY OF CARLSBAD FOR THE PAYMENT OF
A PUBLIC FACILITIES FEE FOR INSIDE THE BOUNDARIES OF COMt.IUNITY FACILITIES DISffiiCT NO. 1,
RECORDED DECEt.IBER 23, 1996 AS FILE NO. 1996-0641 413 OF OFFICIAL RECORDS. THIS ITEI.I
AFFECTS THE SUBJECT PROPERTY, BLANKET IN NATURE AND IS NOT PLOTTED HEREON,
/.iri\_ THE OWNERSHIP OF SAID LAND DOES NOT INCLUDE RIGHTS OF ACCESS TO OR FROM THE SffiEET,
~HIGHWAY, OR FREEWAY ABUTTING SAID LAND, SUCH RIGHTS HAVING BEEN REUNQUISHED BY SAID
t.IAP /PLAT. THIS ITEM AFFECTS THE SUBJECT PROPERTY AND IS PLOTTED HEREON.
r.::'\_ THE OWNERSHIP OF SAID LAND DOES NOT INCLUDE RIGHTS OF ACCESS TO OR FROM THE SffiEET,
~ HIGHWAY, OR FREEWAY ABUTTING SAID LAND, SUCH RIGHTS HAVING BEEN REUNQUISHED BY SAID
MAP/PLAT. THIS ITEIIt AFFECTS THE SUBJECT PROPERTY AND IS PLOTTIED HEREON.
~ EASEMENT FOR STORt.l DRAIN, SHOWN ON PARCEL MAP NO. 17830. THIS ITEt.l AFFECTS THE
~ SUBJECT PROPERTY AND IS PLOTTED HEREON.
~ RESffiiCTIONS SET OUT IN NOTES I AND J ON THE NON-MAPPING DATE SHEET 5 TO THE
~ PARCEL MAP REFERRED TO IN THE UEGAL DESCRIPTION. THIS ITEIIt AFFECTS TI1E SUBJECT
PROPERTY, BLANKET IN NATURE AND IS NOT PLOTTED HEREON.
t:G\__ EASEMENT FOR STORM DRAIN, RECORDING DATE: APRIL 25, 1997, RECORDDING NO. 97-0191489,
\!.::!~" OFFICIAL RECORDS. THIS ITEIIt AFFECTS THE SUBJECT PROPERTY AND IS PLOTTED HEREON.
f.!?._ THE PROVISIONS CONTAINED WITHIN A NOTICE CONCERNING AIRCRAFT ENVIRONMENTAL IMPACTS
~ CI\SE NO. PM 96-09 RECORDED MAY 16, 1997 AS FILE NO. 1997-0226867 OF OFFICIAL
RE•CORDS. THIS ITEI.I AFFECTS THE SUBJECT PROPERTY, BLANKET IN NATURE AND IS NOT
PLOTTED HEREON.
(.;cl_ A COVENANT AND AGREEt.IENT, RECORDING DATE: MARCH 31, 1996, RECORDING NO: 96-0177180, ~ OFFICIAL RECORDS. THIS ITEf.l AFFECTS THE SUBJECT PROPERTY, BLANKET IN NATURE AND IS
NOT PLOTTED HEREON.
~A COVENANT AND AGREEt.IENT, RECORDING DATE: NOVEI.IBER 17, 1998
~ RE,CORDING NO: 98-0745398, OFFICIAL RECORDS. THIS ITEhl AFFECTS THE SUBJECT PROPERTY,
BLANKET IN NATURE AND IS NOT PLOTTED 11EREON.
t:tb\_ A COVENANT AND AGREEt.IENT, RECORDING DATE: NOVEMBER 17, 1998 RECORDING NO:
~ 98;-0745399, OFFICIAL RECORDS THIS ITEhl AFFECTS THE SUBJECT PROPERTY, BLANKET IN
NA. TURE AND IS NOT PLOTTIED HEREON.
/.iri\_ EASEMENT FOR CONSlRUCT, RECONSffiUCT, OPERATE, MAINTAIN AND REPAIR FACILITIES DESIGNED
~ FOR THE GENERAL PURPOSE OF COLLECTING, STORING, ffiANSPORTING, PUMPING AND ffiEA TING
ALL WATER, INCLUDING SURFACE WATER, SffiEAt.l WATER, FLOOD WATER AND GROUND WATER
FLOWING INTO SAID FACIUTIES AND ALL NATURAL AND ARTIFICIAL DRAINAGE DITCHES AND
STRUCTURES OF ANY KINO, WHETI1ER ABOVE OR BELOW THE SURFACE OF THE GROUND,
RECORDING DATE: MAY 24, 1999, RECORDING NO: 99-0353557, OFFICIAL RECORDS. THIS ITEf.l
AFFECTS THE SUBJECT PROPERTY AND IS PLOTTED HEREON.
~ TERMS, COVENANTS, CONDITIONS AND PROVISIONS, RECORDING DATE: JANUARY 20, 2006
~ RECORDING NO: 2D06-DD44258, OFFICIAL RECORDS. THIS ITEt.l AFFECTS THE SUBJECT PROPERTY,
BLANKET IN NATURE AND IS NOT PLOTTED HEREON.
~ MATTERS CONTAINED IN THAT CERTAIN DOCUt.IENT, ENTilLED ENCROACHMENT AGREEMENT,
~RECORDING DATE: MARCH 18, 2011 RECORDING NO: 2011-0146538, OFFICIAL RECORDS. THIS ITEhl
AFFECTS THE SUBJECT PROPERTY, BLANKET IN NATURE AND IS NOT PLOTTED HEREON.
ITEMS #'S SHOWN HEREON ARE STATED AS EXCEPTIONS ON ABOVE REFERENCED COMMITMENT. NO
RESPONSIBILITY FOR THE COMPUETENESS, ACCURACY, OR CONTENT OF SAID REPORT IS ASSUMED
BY THIS MAP.
ITEMS CORRESPONDING TO SCHEDULE "B":
THE LAND REFERRED TO HEREIN BELOW IS SITU A TED IN THE CITY OF CARLSBAD, COUNTY OF SAN
DIEGO, STATE OF CALIFORNIA, AND IS DESCRIBED AS FOLLOWS:
PARCEL 2 OF PARCEL MAP NO. 176JO, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO,
STATE OF CALIFORNIA, FILlED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY
MARCH 21, 1997 AS FILE NO. 1997-0129122 OF OFFICIAL RECORDS.
EXCEPT THAT PORTION OF SAID PARCEL 2 DESCRIBED AS FOLLOWS:
BEGINNING AT THE NORTHEAST CORNER OF SAID PARCEL 2, SAID CORNER BEING A POINT ON
THE SOUTHERLY RIGHT-OF-WAY LINE OF EL CAt.IINO REAL (126.00 FEET WIDE): THENCE ALONG
THE NORTHERLY UNE OF SAID PARCEL 2 AND SAID RIGHT-OF-WAY UNE, NORTH 7~' 25' 24"
WEST 7.84 FEET; THENCE UEAVING SAID NORTHERLY LINE AND SAID RIGHT-OF-WAY LINE, SOUTH
18' 56' 11" WEST 145.16 FEET: THENCE SOUTH 71' 03' 49" EAST 8.50 FEET: THENCE SOUTH 18'
56' 11" IOEST 18.12 FEET; THENCE NORTH 71' OJ' 49" IOEST 8.50 FEET: THENCE SOUTH 18' 56'
11" IOEST 64.50 FEET; THENCE SOUTH 71' OJ' 49" EAST 85.97 FEET TO THE EASTERLY LINE OF
SAID PARCEL 2; THENCE ALONG SAID EASTERLY LINE NORTH 00' 02' 12" EAST 241.25 FEET TO
THE POINT OF BEGINNING.
SAID UEGAL DESCRIPTION IS MADE PURSUANT TO CERTIFICATE OF COMPLIANCE RECORDED MAY
11, 1999 AS FILE NO. 1999-0321010, OFFICIAL RECORDS OF SAID COUNTY.
APN: 212-130-50
ASSESSOR'S PARCEL NUMBER:
212-130-50
DATE OF SURVEY:
APRIL 9, 2013
I
®
VICINITY MAP
NO SCALE
CITY OF
CARLSBAD
ARCHITECTURE •• •• PLIINNING
WilLI .. 1\ IOOTH. •lCIIIICT .01101 l SI.IIIIIL UCIITICT
P.Q.IOI 46£1. c•oL&U~ COL ftOI& (7l0) 4U•&474
======== :: ========
PREPARED FOR
• vertzonwire/ess
P.O. BOX 19707
IRVINE, CA 92623-9707
(949) 222-7000
======== == ========
CONSULTANT
JRN
CIVIL ENGINEERS
232 AVENIDA FABRICANT£,
SUITE 107
SAN CLEMENTE, CA 92672
(949) 248-4685
==========
PROJECT NAME
TAYLOR MADE
5541 FERMI COURT
CARLSBAD, CA 92008
SAN DIEGO COUNTY
======== :: ========
DRAWING DATES
3/7/'1.013
4/11/201.3
DRAWING JRN
DRAWING JRN
==========
SHEET TITLE
TOPOGRAPHIC SURVEY
======== == ========
PROJECTS\ VERtZON\ 12551-A
======== :: ========
C1