Loading...
HomeMy WebLinkAboutMS 13-02; King Property; Minor Subdivision (MS) (5)HYDROLOGY & HYDRAULICS REPORT FOR KING TENTATIVE PARGEL MAP 1600 BUENA VISTA WAY APN 156-142-40 PREPARED FOR Bill and Robin King 5120 Avenida Encinas - Suite 100 Carlsbad, CA 92008 PREPARED BY Robert O. Sukup 4322 Sea Bright Place Carlsbad, CA 92008 RCE 28302 August 25, 2013 Revised November 26, 2013 RECEIVED DEC 10 2ai3 CITY OF CARLSBAD PLANNING DIVISION HYDROLOGY DISCUSSION The proposed 5 lot subdivision is at the top of a knoll. There are single family homes to the north and the other three sides of the property are bordered by streets. No offsite water enters the property. In the existing condition about two thirds of the proposed Remainder Parcel fiows to Arland Road and the rest toward James Drive. The new design has about .07 acres of its new backyard diverted back to Arland Road. This small diversion will not create any issues. Two proposed "bioretention basins" on the Remainder Parcel will help provide mitigation that presently doesn't exist. Proposed Parcels 1, 2, 3 and 4 will continue to flow easterly to existing James Drive with a gross area of 1.16 acres. This property was evaluated under M.S. 98 -16. A copy of this report is in Exhibit "A". A review of the Improvement Plans for James Drive [ CT 98 -16, Drawing No. 382 - 9, Sheet 2] shows an 18" RCP at .7% grade going across James Drive. A check using the Manning Equation indicates an 18" RCP pipe at .7% grade can handle 8.81 cfs. The hydrology report referenced above shows 4.8 cfs in the pipe going across James Drive. My calculations that follow show 3.29 cfs going into the pipe (2.73 from the project and .56 cfs from our half street width of James Drive). To be conservative I used a Q of 4.8 cfs to make sure the proposed 5' long catch basin opening would be adequate I did an independent hydrology calculation using the updated San Diego County charts. The farthest point for the water to travel is from just east of the existing house. Based on a 90' initial start for the drainage at a 1% grade with a C of .5 yields a Ti of 9.5 min. [Figure 3-3]. I will use this as my Tc. The previous report used a Tc of 11 minutes so I have taken a slightly more conservative approach. Per the 100 year Isopluvial Charts and Figure 3-1, we get an I of 4.7. The calculated Q = CxlxA=.5x4.7x1.16 acres = 2.73 cfs. The half street of James Drive that flows into the catch basin on the west side of the street contributes .56 cfs (1.0 C value x 4.7 x .12 Ac). The total projected post development 0100 is 3.29 cfs. The new lots will require the widening of James Drive, Buena Vista Way and the installation of a new catch basin on James Drive that will replace the existing temporary catch basin. The catch basin is a sump condition and needs to handle about .96 cfs per lineal foot of opening. The total Q it has to handle is 4.8 cfs. Per the attached nomograph, the proposed 5' wide catch basin will work fine. I have also included, after this discussion, a copy of the City's aerial topo for the developments to the north of this property. It is difficult to read it but the existing houses just north of the terminus of James Drive flow to the north/northwest to an elevation of about 158. They do not flow southeasterly to existing James Drive. They flow to a sump condition with no outlet. They do not contribute drainage waters to our project. I have included a copy of the proposed grading portion of the TPM as my Hydrology Map for the project. San Diego Connty Hydrology Manual Date: June 2003 Section: 3 6 of 26 Table 3-1 RUNOFF COEFFICIENTS FOR URBAN AREAS LandUse Ranoff CoefBioait "C" NRCS Elements County ElemKits % IMPER. Undistuibed Natural Terrain (Natural) Low Drasity Residential (LDR) Low Doisity Residential (LDR) Low Density Residential (LDR) Medium Density Residential (MDR) Medium Doisity Residentiai (MDR) Medium Density Residential (MDR) Medium Density Residential (MDR) High Density Residential (HDR) High Density Residential (HDR) Commercial/Iadustrial (N. Com) Commercial/Industrial (G. Com) Commercial/Industrial (O.P. Com) Commercial/Industrial (Limited L) Commercial/bidustrial (General L) Peimanoit Open Space ResidentiaL 1.0 DU/A or less ResidentiaL 2.0 DU/A or less ResidentiaL 2.9 DU/A or less ResidentiaL 4.3 DU/A or less ResidentiaL 7.3 DU/A or less ResidentiaL 10.9 DU/A or less ResidentiaL 14.5 DU/A or less ResidentiaL 24.0 DU/A or less Residential, 43.0 DU/A or less Neighboiliood Commercial General Commercial OflRce Professional/Commercial Limited Industrial General Industrial 0* 10 20 25 30 40 45 50 65 80 80 85 90 90 95 0.20 0 27 0.34 0.38 0.41 0.48 0.52 0.55 0.66 0.76 0.76 0.80 0.83 0.83 0.87 Soil Type B 0.25 0.32 0.38 0.41 0.45 0.51 0.54 0.58 0.67 0.77 0.77 0.80 0.84 0.84 0.87 0.30 0.36 0.42 _ 0.45 0.48 0.54 0.57 0.60 0.69 0.78 0.78 0.81 0.84 0.84 0.87 0.35 0.41 0.46 U5EC-.56 0.52 0.57 0.60 0.63 0.71 0.79 0.79 0.82 0.85 0.85 0.87 *The values associated with 0% impervious may be used for direct calculation of tiie runoff coefficient as described in Section 3.1.2 (representing the pervious luaofT coefiBcien^ Cp, for tbe soil type), or for areas tbat will remain undisturbed in perpetuity. Justification must be givoi tibat Ibe area will remain natural forever (e.g., the area is located in Cleveland National Forest). DU/A = dwelling units per acre NRCS = National Resources Conservation Service 3-6 100 h-UJ Ul LL Ui O z w o UJ CO Qt Z) 8 (£ UJ I EXAMPLE: Given: Watercourse Distance (D) = 70 Feet Sk^(s)=1.3% Runoff Coefficient (C) = 0.41 Overland Row Tinie (T) = 9.5 Minutes KXJRCE: ^rport Drainage, Federal Aviatkin Adnr^nistration, 1965 .p_ 1.8 (1.1-C) VD" FIGURE Rational Fonnula - Overiand Time of Flow Nomograph (ft u. o o e 5 4 O Jli. u. o X (9 UJ J (JL o I-o o u. K W 0. o a < o r 2 r I.Q - ,6 .5 .4 .3 .2 .08 .oe .05 .04 L- .03 - ,4 4 L H I *-~-UPCOl dtpriMlPn <») - - .8 L- .19 EtEVATION SECTION NOMOGRAM -CAPACITY. CURB INLET AT SAG 2.6-0651 Plate http://gisweb/ser\'let/com.esri.esrirnap.Esrirnap?Ser\iceNarne=ovrnap<S:ClientVersion=3.... 01/24/2005 Orarige Riverside Cotsity- County of San Diego Hydrology Manual Rainfall Isopluvials 1 on Year Rainfall Eveat - 6 Hours Isopluviai (inches) GIS mmM -E SSS ' 3 0 3 M iles County of San Diego Hydrology Manual 111-^9 IMwcBons for AppMetfhm; (1) Rom pfedpiMoTHn^ datemww 6 )ir anl 24 tv ainoiffife ftjrtbe setected frec|oerx:y. These maps are induded in Itie County HydixAigy Mawal (10,50, and 100 yr maps included in ttie Design and Procedwe Maiuai). (2) Atlgust 6 hr predpitation <if necessary) so tfiat itis wilNn the range of 45% to^% of tfie 24 hr (vet^Mtafion (m^ appHc^e to D^ert). (3) Plot 6 hr pned{xtaijon on the lig^t side of the chart. (4) Diaw a line through ihe paM pwaHel to the (doUed tines. (5) This line is tile intensfty-duratnn curve for the Iccafion l>er r--:lyzed. AppliaUonFonn: (a) S^cted frequem^ year (c) AdHisted PgP' = (d) t^=^.S nm. (6)1= All inJlr. 24 in. N(te: TNs chst replaoes the Int^i^ty-Duration-Ffequency curves used since 196S. P6 ! i 2 , 23 ; a ~ SLS : I 5 2JB3 (3.9SsS.g7. 6.S9 j7.90:9.2a;10.5*:n.gT3L17lt4.48»t&B1 7i 2.t2 i3.18[4a«' S.30T6:»'7.4aT8jy ; 9St j 1060 ItJ6j 12.78 ;253!3.37! 4.21:5.05;5J0! 6.74 f 7«1 9.4Zl 9Sf 1! 15 20 2S I i I I S3 ; < I 1 1.S8 '1.30 ii.»i2JS9\3MtSJB9i«S*i 5.19^1^84 I 6.4»; :iaii 0J3 1J62!Z15' 2J9j3.28^3.77i 4.31 ' \ 539 7.13; 77» 1.40i1J7:a33r2,B0i3^7i3.ra I 440 ! 4JL 90 o.eo asa 1.03; 1J», ose'Ci.te] JOB 034 0126 "oi? 0.17 080! 1.06 i 061)0.82: i.TOjeo7:2.4i 1.49,Tre ;2.<»; r.M|T»; 1.861 "i.oeiijs3:i:4Si 0.51 [QB! 085 hi>a: iia 0.44|0£8: O73|O8S!i.03 2.78 i aio 2.12 T 2.39 iJ3Tri4 4.15; 3-4|] 2XH 5L13 &60 4.56 I 4:98 179 8^ O39ift58iO65i0.7810.91 ft,33|0.43i eaio.36 054^0:851076 047|SsStoSg a25i033l 0.421050 0.58 1.38M.S3i i.70: 1.8? 1.1B 1 1.32 I IJH I 1.18 1.311 1.62 1.44 0.87 098 1 1.Ce> 1.19 0JS ;O» i 094 j 1.03 0J7 ' 075 i QMi tt9g 4JS 1:58 118 2^ 2.04 1.78 1.S7 1J30 1.13 1.00 F 1 G P R g Inlensfty-DBraftm Design Chart - Tenylate EXHIBIT "A" A L^ND SPACE ENC3INEERING, INC. PLANNING — CIVIL ENGINEERING — SURVEYING 201 EAST GRAND AVE.. SUITE 2-F • ESCONDIDO. CA 92025 PHONE (760) 741-2689 FAX (760) 741-2616 -6 HYDROLOGY 5C HYDRAULICS REPORT PROJECT CARLSBAD TRACT M.S. 98-1 6 JAMES DRIVE, CARLSBAD DATE: 7/28/99 •pro ALEKSANDAI^ PANTICH R.C.E. 32734 EXP. 06-30-02 C:\LSQSeOS\H I .GOV KUANNiNS - CIVIL-ENGINEERING - SURVEYING 201 EAST SfUfC AVE.. SUITE 2-F. ESCOfCIOa CA S202S PHONE (613) 741-26B9 SHEET NO. CALCULATED GY. CHECKED BY SCALE OF DATE. OATE. rti/- -A ! I /•7^ \ \ ^/^^ Wfeo ^ 5.S7 ' • : i ; • ; , ^ i • ' : • : ' i = ^ • • -i " ; SAN DIEGO COUNTY DEPARTMENTOF SPECIAL DISTRICT SERVICES DESJGN M/\NUAL , APPROVED '^'••^'-'^•<>T URBAN AREAS OVERLAND TiME OF FLOW CURVES DATE Z Jl/l/£Z—\ APOENDIX X-C ;ou;fry OF SAN DIEGO DEPARTMENT OF SANITATION g. FLOOD CONTROL 100-YEAR Q-mm pmrnmidii "20.^ ISOPLUVIALS OF lOO-YEAR G-HOUR 2-5° lo' 33' PREctrnvsTiori in mnw^ cr AH I;:C!I I Prtpn ' U.S. DEPARTMEN .Br,.... . OCEANIC ANO AT.-fPECJAL STUDIES DHANCII, OFFICE OF II I 116* COUNTY OF SAH DIEGO DEPARTMENT OF SANITATION & FLOOD CONTROL '•5' 30' 15' 2^^- lo' 33' '•5' ! U.S. DEPARTMEN NATIONAL OCKAMC AND AT: SPECIAL STUDICS UKANCII. OFFICE OF II 100-YEAR 24-IIOl|R PnECIPITATION '"20-/ISOPLUVIALS OF IQG -YEAR 24-tlQUn PnECIPITATION IM EMTliS OF AN INCH 30' -I hf r OF COMMERCE USniCNIC AUMINISTRATIOM UliOLOCY. NATIONAL WEATHER SERVICE IK I" /|f;« . 0 30' IS) 117' .in« M6- INTENSrTy-DUKATlli^t.iGN CHART March 1902 Directions for Application: 1) From precipitation naps detennine 6 hr. and 24 hr. amounts for the selected frequency. j These maps are printed in the County Hydrolotjy Manual (10, 50 and 100 yr. maps included in tHe Design and Procedure Manual). j 2) Adjust 6 hr. precipitation (if necessary) so that it is within the range of 45% to 65% of the 24 hr. precipitation. (Not Applicable to Desert) 3) PlDt 6 hr. precipitation on the right side, of the chart. 4) Draw a line through the point parallel to the plotted lines. 5) This line is the intensity-duration curve for the location being analyzed. Application Form: 0) Selected Frequency /QO yr. 1) Pfi • ^'<S in.. P24= . *P. = S'S V 2) Adjusted *Pg= 3) t^ = min. 4) 24 in. in/hr. *Not Applicable to Desert Region 30 40 50 1 APPENDIX XI IV-A-14 O.P 0 3 —1 I 3 0.4 0506 oe lon-nip ? 4 5 _l L_ .OB 0.1 .2 "T—I—I—r- .5 .6 ,7 .$ r~\— 1.0 T B IO _l I I I ZO I 30 40 50 eo eo —I I • 1 • • • —r- 2 —r- 3 -I—r- 4 -I 1—I—I—n— sere lo 20 -1 1—I—r— 30 40 I File: S802.WSN SCudy Data: 7-2S-99 Tloa: 20: 6:24 LANS SPACE ENGIHEERINO Planning - Civil Engineering - Surveying 201 E. Grand Ave., See 2-F Escondido, California 92025 Telephone (619) 741-2669 W S F C H - CIVILDESIGN Vera 6.1 File: 9602.WSN Srudy Data: 7-26-99 Time: 20: 6:24 WATEH SUEFACE PROFILE LISTING CAELSBAD MS.98-16 JAMES ORTVE 18" STOKM DHAIN PASS 1 Dato: 7-26-1999 Time:20: 8:18 Station L/EleD .00 2.73 2.73 HYDRAULIC 2.73 1.19 3.92 3.34 7.27 .72 9.99 2.24 12.23 i.ee 14.09 1.S5 15.65 1.27 Invert Elev Cb Slope 149.22 .12050 149.5S JUHP 119.55 .12050 149.69 .12050 150.10 .12050 150.42 .12050 150.69 .12050 150.92 .12050 151.11 .12050 Deptb (FT) **«««*«« 2.670 2.400 .en .626 .aci .933 .972 1.013 Water Elev 151.890 151.949 150.366 150.521 150.957 151.320 151.627 151.891 152.118 (CFS) 13.6 13.6 13.6 13.6 13. £ 13.6 13.6 13.6 13.6 Val Vel 1 Energy | Super | Critical j Plow Top | Height/|Baae Wt| |Ho >. (FPS) Bead I Grd.El. I Elev | Depth | Width |Dla.-FT|or I.D.| 2L )PrB/Plp -1- -1- -1- -1- -I- -1- -1- -I- 1. SF Ave{ EF jSE DpthlFroude NjNora Dp | *N' | | ZR jType Ch I j «*«««»*** I Kltai**** I I j I I ******* I I I I I I II 7.70 .920 152.810 .00 1.370 .00 1.50 .00 .00 1 .0 -I- .019441 .05 2.67 .000 .661 .014 I I I I I I i I 7.70 .920 152.868 .00 1.370 .00 1.50 - I- .00 FIPB .00 .00 1 .0 13.63 2.959 153.335 I I I II .00 1.370 1.49 1.50 .00 .00 1 1--1- -I- -I- -1- -I- -1- -I- .057174 .07 .62 3.004 .661 .014 .00 PIPS 13.5a 2.863 153.384 .00 1.370 1.49 1.50 .00 .00 I •1-•I- .00 PIPE .052534 .16 .83 2.920 .661 .014 I II I llll 12.SS 2.603 153.560 .00 1.370 1.48 1.50 .00 .00 1 .0 -I-•I- .046438 .13 .00 PIPE 12.34 2.366 153.606 -I- ,|. _|. .041106 .09 .90 2.514 .US 2.711 .661 .014 I IIM .00 1.370 1.47 1.60 .00 .00 J .0 .661 .014 .00 FIFE 11.77 2.151 153.778 - .00 1.370 1.45 1.50 .00 .00 1 .0 .036437 .00 PIPE .07 .93 2.327 .661 .014 I II I llll 11.22 1.955 153.846 .00 1.370 1.43 1.50 ,00 .00 1 .0 -I-•I- I- .032346 .05 .97 2.150 .661 .014 .00 PIPE I II I llll 10.70 1.776 153.896 .00 1.370 1.40 1.50 .00 .00 1 .0 .028786 .04 1.01 1.982 .661 .014 .00 PIPE W S P G N - CIVILCESIGN Vera 6.1 File: 9802.WSN Study Date: 7-26-99 Time: 20: 6:24 WATER SURFACE PROFILE LISTING CARLSBAD KS.98-16 JAMES DRIVE 18" STORM DRAIN FAGS Date: 7-26-1999 Tiaa:20i 8:20 Station L/Eleo 16.92 1.03 17.95 .83 18.78 .64 19.41 .42 19.83 20.00 JUHCT OTH 24.00 46.66 70.66 UHCT BTR 74.66 Invert Elev Ch Slope 151.26 .12050 151.38 .12050 151.48 .12050 151.56 .12050 151.61 .12050 151.63 .07000 151,91 .00686 152.23 .00750 152.26 Depth (FT) **«««««« 1.058 238.47 .00700 1.107 1.160 1.218 1.286 1.370 2.402 2.436 2.435 Watar Elev 152.317 152.490 152.643 152.777 152.896 153.000 154.312 154.666 154.695 Q (CFS) 13.6 13.6 13.6 12.6 13.6 13.6 8.3 8.3 8.3 Val Vel I Energy | Super | Critical j Flow Top | Belght/1 Base Wt| |Bo Wth (FPS) Head I Grd.El. I Elev | Depth | Width |Dia.-FTjor I.D.| ZL |Fra/Plp -1- -I- -1- -I- -I- -I- -I- -1- I- SP Avej HP |SE Dpth|Froud« NjNom Dp | *N" | |, ZR |Typo Ch I 10.20 1.616 153.933 .00 1.370 •I- 1.37 1.50 -1- .00 .00 1 -1-1- .025711 .00 PIPE .03 1.06 1.821 .661 .014 I II I llll 9.73 1.469 153.959 .00 1.370 1.32 1.50 .00 ,00 1 .0 •I-•I-•I- .023056 .02 1.11 I I I 9.27 1.336 153.978 1.665 00 1.370 .661 .014 1.26 1.50 .00 PIPE .00 .00 1 •I- .661 .014 .00 PIPE .020779 .01 1.16 1.513 I II I llll 8.84 1.214 152.992 .00 1.370 1.17 1.50 .00 .00 1 .0 •t-•I- .00 PIPE .018899 .01 1.22 1.360 .661 .014 I II I Iill 8.43 1.104 154.000 .00 1.370 1.05 1.50 .00 .00 1 .0 -I- -1- -1- -I- -I- -I- -I- -1- I- .017503 0.00 1,29 1.198 .661 .014 .00 PIPE I II I llll 0-03 1.002 1!I4.0Q: .00 1.370 .04 1.50 .00 .00 1 .0 .012081 -I- -I- .05 1.37 1.000 -I- -1- -I- I- .014 .00 PIPE I II I llll 4.69 .342 154.654 .00 1.115 .00 1.50 .00 .00 1 .0 .007223 -I- -I- -I- -I- .34 2.40 .000 1.268 .014 .00 PIPE 4.69 .342 155.008 .00 1.115 .00 1.50 .00 .00 1 .007223 .03 2.44 .000 4.69 .342 155.037 .00 1.115 ,014 .00 1.50 .00 PIPE .00 .00 1 .0 .007223 1.72 2.43 .000 1.252 .014 I- .00 PIPE W S P G N - CIVILDESIGN Vers 6.1 File: 9802.WSN Study Data: 7-26-99 Siaa: 20: 6:24 WATER SURFACE PROFILE LISTING CARLSBAD MS.98-16 JAMES DRIVE 18' STORM DRAIN PAGE 3 Data: 7-26-1999 T1IM:20: 8:23 **i^HIRi*ik****«*«««********«*****ft*«»«*«*»«.«*«**M***«*««*******a«*ii*i>*******«**************"****************************«****a*^ 1 Invert | Depth | Water | Q | Vel Vel | Energy | Super | Critical | Flow Top | Height/1 Baae Wt| |No Wth Station 1 Elev | (FT) j Elev | (CFS) | (FPS) Head | Grd.El. j Elev ) Depth | Width |Dla.-FT|or I.D.j ZL |Pr»/Plp L/ElBB ***««*»»* Ch Slope ******** III SF Ave !*«**«*«*a 1*******1 ******** llll HF 1 1 SE Dpth 1 Froude N|Nom Dp | *******!********!**»**«*«1 •H" ******* 1 ******* 1 1 ZR ***** jTypa Ch 1 ******* 313.13 153.93 llll 2.505 156.435 8.3 4.69 .342 1 156.776 1 .00 1 1.115 1 .00 1 1.50 1 1 .00 .00 1 .0 JUNCT STR .00750 .004843 llll .02 1 2.50 1 .000 1 1 .014 1 1 1 .00 PIPS 317.13 153.96 llll 2.944 156.904 4.8 2.74 .116 1 157.021 1 .00 1 .846 i .00 1 1.50 1 1 .00 .00 1 .0 37.00 .00676 .002462 .09 1 2.94 1 .000 1 .841 1 .014 1 1 1 .00 FIPB 354.13 154.21 llll 2.791 157.001 4.8 2.74 .116 1 157.118 1 .00 1 .846 1 .00 1 1.50 1 1 .00 .00 1 .0 JUNCT STR .00750 .001539 .01 1 2.79 1 .000 1 1 .014 1 1 1 .00 PIPE 358.13 154.24 2.942 157.182 2.4 1.37 .029 1 157.211 1 .00 1 .589 1 .00 1 1.50 1 1 .00 .00 1 .0 1 _ ^'-'—1-.-^ CUI tASi s«AHj AVE.. SUITE c-f. ESCOWIOa CA 32025 PHONE (6191 741-2689 CALCULATED BY. CHECKED BY SCALE QF DATE- DATE. i33diS N0S1IM K1 to CO o ^ 4