HomeMy WebLinkAboutPIP 00-01; MV Technical; Planned Industrial Permit (PIP) (2)March 1, 2001 Kenneth D Smith Architects Suite B 435 W Bradley Av El Cajon CA 92028 SUBJECT: PIP 00-01 - MV TECHNICAL Thank you for applying for Land Use Permits in the City of Carlsbad. The Planning Department has reviewed your resubmittal of the Planned Industrial Permit, application no. PIP 00-01, as to the issues of concern to staff You should also be aware that some Engineering Department issues still remain. These issues, listed below, must be addressed before a final determination can be made on the application. In addition, the City may, in the course of processing the application, request that you clarify, amplify, correct, or otherwise, supplement the basic information required for the application. Please contact your staff planner, Michael Grim, at (760) 602-4623, if you have any questions or wish to set up a meeting to discuss the application. Sincerely, Planning Director MJH:MG:mg C: Chris DeCerbo Jeremy Riddle - 1635 Faraday Avenue Carlsbad, CA 92008-7314 (760) 602-4600 FAX (760) 602-8559 w.ci.carlsbad.ca.us @ I ISSUES OF CONCERN NO. PIP 00-01 - MV TECHNICAL Engineering: 1. 2. 3. 4. 5. 6. 7. 8. 9. On the site plans, revise waterline connection near the easterly driveway so that it is centered in the propose driveway and connects to the existing public main in the street as described in the first review comments. The existing 8-inch stub was not installed in the same location as the driveway proposed by this project. The resubmitted plans now depict a proposed public main installed in the parkway in the “dry” utility area under drainage structures. Please note this alignment will not be permitted. On the site plan, include quantity of remedial earthwork. This information has been added to the preliminary grading plans, but is also required on the project data area on the site plan. On the site plan, add a note regarding storm water quality stating that all inlets collecting water from within paved areas of the parking lot will be fitted with fossil filters or approved alternative. Clarify how storm run-off will be intercepted and conveyed from the 30-foo high rear slopes. Add a note to the site plan that indicates the minimum sight distance required per CalTrans Standards (30 mph x 11 = 330 feet). This will help clarify the distances you have added to the site plan meet the minimum requirements. On the site plan, add the cross-section of the retaining wall along the easterly property line. Although a notation was added for the cross-section, it does not appear to be on the exhibits. On the site plan, clarify that the turning radius is for a 60-foot radius vehicle per 407-0. On the site plan, remove the proposed easement line within the City right-of-way as shown on the returned plans. A redlined check print is enclosed for the applicant’s use in making the requested revisions. This check print must be returned with the plan revisions to facilitate continued staff review.