Loading...
HomeMy WebLinkAboutPIP 86-07; Kaiser Electro Optics; Planned Industrial Permit (PIP) (6)PLANNlNG DEPARTMENT f -. 6 F)LE P/P E? 6-7 2075 LAS PALMAS DRIVE CARLSBAD, CALIFORNIA 920094859 (619) 438-1161 d January 22, 1987 Krommenhoek/McKeown & Associates P.0 Box 82208 San Diego, California 92137-2088 RE: PIP 86-7 The Community Development Director, the City Engineer and the Planning Director have reviewed the application you submitted for the above-referenced project. Based upon this review, it has been determined that there are major problems associated with your application which must be addressed before this application can be scheduled for a hearing. The problems or issues are listed below. Also, the name of the project planner and project engineer is provided. You should setup a meeting to discuss the issues with the appropriate staff member. Until these issues are resolved your application will be determined as incomplete. PROBLEMS/ISSUES PROJECT PLANNER Parking lot landscape inadequate Ed Ruiz lot coverage. dept. policy (warehouse use) ti overhang. " . Bob Wo j c ik / Parking inadequate pursuant to PROJECT ENGINEER Queuing area (stacking) Location of loading area. Elevations - break up 'Driveway location to be per S.P. 200 - condition for joint access to lot 7. Show grading, contours, utilities, " "_ . drainaee. etc. SEE ATTACHED "CHECKLIST FOR SITE PLANS" _. ' CITY OF CARLSBAD -'NGINEERING DEPARTRENT " PRELIflINARY PROJECT REVIEW CHECKLIST FOR SITE PLANS PROJECT NAME: . PROJECT ID: LOCATION: PROJECT ENGINEER: PROJECT PLANNER: DATE OF REVIEW: PLAN QUALITY Name and address of the owner whose property is proposed to be devel- oped. Name and address of developer. Name, address, and registration num- ber of the Architect or Registered Civil Engineer who is in responsible charge of the project. North point and scale of the plan. Date of preparation and revision of the plan. The street eddress(es) and Asses- sor's Parcel Number(s) of the lot(s) proposed to be developed. Location of the following facilities and physical featuures, labeled "existing" or "proposed" that are within 100 feet of the project: A. Driveways and Alleys B. Street Intersections C. Curb and Gutter 0. Sidewalks E. Roadway Position and Name F. Roadway Cross-Section G. Median Islands H. Buildings I. . Utility facilities 3. Existing Contours: 1' intervals for slopes less than 52; 2' intervals for slopes between 5% and 10%; and 5' intervals for slopes over 10%. K. Proposed Contours: 1' intervals for slopes less than 5%; 2' intervals for slopes between 5% and 10%; and 5' intervals for slopes over 10%. L. Drainage Facilities M. Water Courses N. Traffic Control Facilities 0. Other Improvements (swimming The location of the following facilities and phyaical features labeled "existing" or "proposed" on the project site: A. Items enumerated in Item ' 7 8. Major vegatation with size and C. Free-standing signs D. Parking stalls and facilities E. Landscaping Location(s) and use(s) of pools, retaining wall, etc.) above type COMMENTS easements. I. Quantities of soil import, export, and total quantity moved in cubic yards I. A Vicinity Map.