HomeMy WebLinkAboutPIP 88-10; Carlsbad Oaks East Lot 30; Planned Industrial Permit (PIP) (4)" 2075 US PALMAS DRIVE CARLSBAD, CA 92009-4859 TELEPHONE (619) 438-1161 aittf af (aarlsbab PLANNING DEPARTMENT October 26, 1988 Krommenhoek/McKeown & Associates 1515 Morena Boulevard San Diego, CA 92110 Thank you for applying for Land Use Permits in the City of Carlsbad. The Planning Department has reviewed your Planned Industrial Permit, application no. PIP 88-10, as to its completeness for processing. The application is incomplete, as submitted. Attached are two lists. The first list is information which must be provided to complete your application. The second 1 ist is issues of concern to staff. To help speed processing of the application, it is suggested that each item on the lists be rectified or addressed in a letter to your staff planner. You should be aware that no processing of your application can occur until the application is determined to be complete. Please contact you staff planner, Lance Schulte, at (619) 438-1161, if you have any questions or wish to set up a meeting to discuss the application. Sincerely, MICHAEL J. HOLZMILLER /q P1 anni ng Director MJH: LBS/af cc: Charles Grimm Mark Granich Clyde Wickham LIST OF ITEMS NEEDED TO COMPLETE APPLICATION: PIP 88-10 PLANNING: 1. Location of all buildings within 100 feet not provided. 2. Clear indication of area devoted to manufacturing, warehouse land use on floor plans and table. 3. Clear indication of number of vehicles used in conjunction with manufacturing and warehouse spaces and/or area as per 21.44.020(30 and 32) on site plan and table. 4. Signage not shown on building elevations. ISSUES OF CONCERN PLANNING: \ 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Use of retaining wall. Adequacy of lunch areas as per 21.34.070(3). Intrusion of road without bermed screening into 35’ setback as required by SP-200. Justification for use of 2’ overhang for standard parking spaces. Need to create unique yet unified identity for each building through site design, building graphics and landscaping. Legal mechanism to assure proposed 1 and use, ADT and parking demands. Quantity of proposed 1 andscapi ng . Colors and detailing of buildings. Show compliance with Specific Plan-200; specifically, E. Architectural Guidelines, page 14. Concern over site plan’s abil i ty to accommodate intended uses. COMPLETENESS REVIEW AND ISSUES STATEMENT FOR The Engineering Department has completed its review of the subject project for application completeness. The application and plans submitted for this project are: Complete and suitable for continued Engineering review. Incomplete and unsuitable for further review for the following reasons: x - 1. R== m S~ECIFIL s~orj~mm w *I.?. APPL~~O~. * 6Lw 2. WdkUTTme €iWA.W I' I' 3. w1q. 8 pmPQW0 COWOR* ~M~PILL~ v\Ud\M WM -c- G.---+ In addition the Engineering Departmen -7 made a preliminary review of the project for Engineering issues. (See attached initial review and assessment checklist.) Major engineering issues which will need to be resolved or adequately addressed for this project are as follows: 2. 3. A1 so attached is a red1 ined check print of the site plan. This plan should be given to the applicant for corrections and changes as noted. Please have the applicant return the redlined print with the corrected site plans to assist us in our continued review. c: Project PI anner LANGE hPECIFIC REOULBEMENTS 'Y 1. Four (4) copies 1 ude -the 'fo name and etc., and L3G. of site plan (24" x 36" folded to 8 1/2 x 11") shall Ilowing information: address of applicant, their registration numberq and/or architect, all easements 't dimensioned location of: distances between buildings and/or structures building setbacks (front, rear and. sides) location, height, aneof walls and fences location of freestanding signs all driveways, alleys and streets (with street names) to scale on adjacent and across the street properties for a distance of 100 feet beyond the 1 imits of subject site existing curbs, gutters, sidewalks and existing paving widths within 100 feet on adjacent and across the street properties / watercourses I/ typical street sections @ existing contours and proposed contours in 2' intervals /any existing median island within 100 feet of subject site nearest cross streets on both sides with plus or minus distances from subject Ii drainage te facilities and/or flow lines @ location of all buildings within 100 feet of subject properties 8 @ grading quantities VLL ?? a vicinity map showing major cross streets existing utilities within 100 feet of subject properties @ label all facilities as "existing" or proposed" north arrow and scale Page 1 of 2