Loading...
HomeMy WebLinkAboutPIP 89-16; Creekside; Planned Industrial Permit (PIP) (5)January 72, 7990 Ronald Young 9252 Chesapeake Drive San Diego, CA 921 23 SUBJECT: PIP 89-7 6 Thank you for applying for Land Use Permits in the City of Carlsbad. The Planning Department has reviewed your Planned Industrial Permit, application no. PIP 89-76, as to its completeness for processing. The application is incomplete. Attached are two lists. The first list is information which must be submitted to complete your application. All list items must be submitted simultaneouslv at the Communitv Development Building counter, and to the attention of Erin Letsch. A COPY of this list must be included with your submittal. No processing of your application can occur until the application is determined to be complete. The second list is issues of concern to staff. When all required materials have been submitted as outlined above, the Cify has 30 days to make a determination of completeness. If the application is determined to be complete, processing for a decision on the application will be initiated. In addition, please note that you have six months from the date the application was initially filed, December 12, 1989, to either re-submit the application or submit the required information. Failure to resubmit the application or to submit the materials necessary to determine your application complete shall be deemed to constitute withdrawal of the application. If an application is withdrawn or deemed withdrawn, a new application must be submitted. Please contact your staff planner, Anne Hysong, at (679) 438-7 767 extension 4328, if you have any questions or wish to set up a meeting to discuss the application. Sincerely, MICHAEL J. HOUMILLER Planning Director MJH:AH/lh c: Gary Wayne CrystallAngelina Erin Letsch Bob Wojcik Data Entry 2075 Las Palrnas Drive - Carlsbad, California 92009-4859 - (619) 438-1 161 LIST OF ITEMS NEEDED TO COMPLETE APPUCXTION: NO. PIP 89-16 PUNNING: 1. Submit roof plan and screening proposed for any roof mounted equipment. ENGINERING: 1. 2. 3. 4. 5. 6. 7. All facilities labeled as “existing“ or “proposed‘. (call out) Typical street cross sections of all adjacent and streets within project. Show typical section for: 1) Camino Vida Roble and 2) your onsite driveway. Width, location and use of all existing andlor proposed public or private easements. Show water easement through entire site. Clearly show parking stall and isle dimensions and truck turning radii for all parking areas and loading areas (407E) 42 ft. radius. Show all existing and proposed street lights and utilities (sewer, water, major gas and fuel lines, major electric and telephone facilities) within and adjacent to the project. Show existinglproposed water and sewer laterals (show onsite systems). Approximate contours at 1 ’ intervals for slopes less than 5%, 2’ intervals for slopes between 5% and lo%, and 5’ intervals for slopes over 10% (both existing and proposed). Existing and proposed topographic contours within a 100 foot perimeter of the boundaries of the site. Existing onsite trees; those to be removed and those to be saved. Location, width andlor size of all watercourses and drainage facilities within and adjacent to the proposed subdivision show location approximate size of any proposed detentionlretention basins. /SUES OF CONCERN PUNNING: 1. ARCHITECTURE: a) Submit samples of aggregate to be used on exterior and color sample of reveals. Loading doors should match or contrast with aggregate. b) Break up roof line on buildings 1 and 2 using same treatment as Building 3. P ISSUES OF CONCERN - PLANNING - (CONTINUED): 2. Loading door nearest to eastern property line may be visible from street. Provide graphic showing line of sight from center line of street to building loading door. 3. Show 2 required handicap parking spaces (see attached requirement). 4. Provide a walk wider than 5' with 2 112 foot overhangll7.5 foot parking space 5. CC8R's are required for multi-tenant buildings addressing outdoor storage of 6. Loading bays at western end of project have a back-up conflict. 7. Loading bay at eastern end of project interferes with eating area. Relocate if &r provide full length 20' parking space with wheel stop. m equipment. loading bay remains. e ENGINEERING: 1. Your driveway entrance needs to be widened (as shown on the plan) to provide Caltrans 407E (42 ft. radius) truck access. 2. Need to provide truck access and circulation onsite to and from your truck loading areas and trash dumpsters for Caltrans 407E (42 ft. turning radius). Copy of template included. What you are proposing does not work. 3. Your proposed sign nearest Camino Vida Roble needs to be relocated to provide the required corner sight distance, as shown on the plan. 4. You are proposing drainage swales between your parking lot aisles. This is discouraged. Tipped sections with concrete curb and gutters are preferred. 5. Need to direct your onsite drainage into your proposed 0-24, not out your driveway. 6. You need to provide for a failsafe overflow for the drainage system along the west side of the project. This is in the event the 2 existing inlets on the adjacent southerly property plug-up. You might want to consider keeping the existing concrete drainage swale instead of changing to the 2-8" plastic drain pipes and then also have to provide the failsafe overflow also. 7. Need to provide for the drainage from the southerly slope adjacent to building #3. You need to provide something like a 0-75 type C drainage ditch and indicate the direction@) of flow. 8. You will need to get a letter from Carlsbad Municipal Water District approving your proposed improvements within their easement. 9. To be forwarded next week is a redlined No. "1" check print of the site plan. This plan should be given to the applicant for corrections and changes as noted. Please return the redlined print with the corrected site plan to assist us in our continued review.