Loading...
HomeMy WebLinkAboutPIP 91-02; H. A. Lavezzi Distributing Corporate Headquarters; Planned Industrial Permit (PIP) (5)/- December 9, 1991 Ware 81 Malcomb Architects 6125 Cornerstone Court, Suite 200 San Diego, CA 921 26 Attention: Jim Edwards RE: PIP 91-2 - H.A. LAVEZZI DISTRIBUTING CORPORATE HEADQUARTERS This is to inform you that the items previously requested to make your Planned Development Permit, application no. PIP 91-2, complete have been received and reviewed by the Planning Department. It has been determined that the application is now complete for processing. Although the initial processing of your application may have already begun, the technical acceptance date is acknowledged by the date of this communication. Please note that although the application is now considered complete, there may be issues that could be discovered during project review and/or environmental review (see attached list of issues). Any issues should be resolved prior to scheduling the project for public hearing. In addition, the City may request, in the course of .processing the application, that you clarify, amplify, correct, or otherwise supplement the information required for this application. The Planning Department will begin processing your application, as of the date of this communication. Please contact Anne Hysong, at (619) 438-1161 extension 4477, if you have questions or wish additional information. Sincerely, MICHAEL J. HOLZMILLER Planning Director MJH:AH:vd cc: Gary Wayne Robert Green Erin Letsch Bob Wojcik File Copy Data Entry Marjorie/Steve ISSUES OF CONCERN NO. PIP 91-2 - H. A. MVEZZI DISTRIBUTING CORPORATE HEADOUARTERS PLANNING: 1. Standard parking spaces are 20’ in length. A 2.5’ overhang is permitted only when the overhang does not encroach into the required side or rear yard setbacks. Standard spaces shown along the rear property line include a 2.5’ overhang which encroaches into the required lo’ setback. Revise the site plan to show the full 20’ of length for these spaces outside the setback. The space adjacent to the planter requiring an additional 5’ of back-up distance cannot be accommodated at this location. Change the Site Notes on Sheet 2, Item 9, as follows: Compact spaces are 8’ x 15’ with no overhang. 2. Page 15 of the Carlsbad Oaks Specific Plan calls for solid concrete or masonry walls to screen equipment including delivery trucks. The delivery truck parking area must be screened with a masonry wall; the proposed black vinyl coated chainlink fence around the remainder of the lot with heavy landscaping to screen is acceptable. Resubmit plans showing the continuation of the masonry screen wall facing Loker Avenue along the northern property line to the end of the truck parking area. The wall shall be stepped down from 12’ to 8’ (include a detail of the stepped design on the plans). 3. The painted concrete accent with sand blasted aggregate as shown on the attached print is an acceptable alternative to your proposal. Please resubmit plans showing this combination of sandblasted aggregate and painted concrete on the side and rear building elevations. 4. On Sheet 5, Sections A and B are provided, however, the locations of these sections has not been identified on the site plan. Please indicate the locations on the site plan. 5. It will be necessary to reduce the visual impact of the proposed 12’ screen walls facing Loker Avenue with landscaped berms (maximurn 3:l). Resubmit plans showing berms at these locations. This will require the relocation or elimination of the 5 parking spaces proposed along the northern property line. Please return the Landscape Plan check print with your next submittal; landscape plans will not be reviewed by our Landscape Consultant until the check print is returned.) 6. There is area available to provide the full 20’ parking spaces with no overhang along the south side of the building. This change will allow the full utilization of the 5.5’ wide planter. 7. Provide a graphic detail of the proposed security gates. The gates shall be a solid metal material which is architecturally compatible with the building and screen wall. To visually enhance the screen wall, the Planning Department is recommending that pilasters be added on each side of the gates (see attached check print of Sheet 7). 8. All plans must be consistent; the delivery truck spaces which were deleted on the site plan must also be deleted from the grading plan. 1. Site drainage is not to City Standard of 1% minimum grade. Several areas have 0.70% and one area near loading docks have 0.50% grades. 2. The site plan shows no provision for urban pollutant mitigation. Please return all redlined checkprints to facilitate prompt review.