HomeMy WebLinkAboutPIP 93-02A; Callaway Golf Test Facility; Planned Industrial Permit (PIP) (3)i i- May 26, 1995 Mark mgan Smith Consulting Architects 5355 Mira Sorrento Place, Suite 750 San Diego, CA 92121 SUBJECT: PRE 95-16\Callaway Golf Test Facility APN: 212091-04 & 5 Preliminary review of your project was conducted on May 25,1995. Listcd below are the kues raised by staff. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. The Dreliminan review does not remesent an in- deDth analvsis of vour Droiect. Additional issues of concern mav be raised aner your amhation 1. 1. The propod building addition which includes the first and secd floor storage areas and the elevator requires an amendment of Planned Industrial Permit - 9342(A). As a reminder note for any future amendment application, all building elevations rn- be illustrated to show compliance with building height standards 2. The Planning Department calculates packing space demand for a project by gross floor area, which constitutes the area within the building walls, including closet and utility anas, stairways, comdors, bathrooms, and crawl spaces, therefore, the first floor am of the elevator must be counted in the square footage totals for the propod building addition. The nqucsted building addition (approximately 610 square feet) would created the demand for 3 additional onsite parking spaces, based on the City’s Parking Ordinance requirement of one (1) parking space per every 250 square feet of grca floor area for a testarch and development land use. The Planning Department does not support a variance from the lPS0 quam feet parking standard and recommends that the additional parking spaces be placed at the west end of the long linear parking area between the entrance gate and the end packing space. 3. The planning Department recommends that large two-story buildings maintain a fiftan (15) foot setback from the top of slope, however, in this case, since only the comer of the propod building addition encroaches two (2) feet into the fifteen (15) foot slope setback area, and the building addition is not highly visible from public streets, the Planning Department can support your request 2075 Las Palmas Drive - Carlsbad, California 92009-1 576 - (61 9) 438-1 161 @ c PRE 95-16 - Callaway Golf Test Facility May 26,1995 Page 2 Engineering: 1. Engineering Department staff are of the'understanding that Planning Department staff will require three (3) additional parking spaces to be provided for this project. Due to site constraints, a location where these additional parking spaces could be provided is directly west of and adjacent to the existing parking spaces This location is acceptable to Engineering staff provided that a minimum queuing distance of 20 feet is provided to the end of the southerly entrance gate (as it swings open) of the entrance gate mechanism, which is now being shown. 2. A field review indicated that a curb opening which was supposed to be provided along the southerly curb lii of the am= driveway to allow on-site drainage (which does not sheet flow from the actual parking spaces) to discharge through the golf green, for pollutant elimination purposes, was not provided As a condition of approval for this project amendment, this curb opening will be requid 3. The security gates which an now being shown wen not shown on prior plans An these gates proposed or currently constructed? Regardlcs, in accordance with City Stan- a minimum 20 feet queuing distance from the back of sidewalk (or rightd-way line if there is no sidewalk) to the gate is required. Please contact Jeff Gibson at (619) 438-1 161, extension 4455 if you have any qucstim . Assistant Planning Director C: Bobbie Hodet File copy Data Entry