Loading...
HomeMy WebLinkAboutPIP 93-02B; Callaway Golf Test Facility Elevator; Planned Industrial Permit (PIP)- CITY OF CARLSBAD LAND USE REVIEW APPLICATION FOR PAGE 1 OF 2 I 1) APPLICATIONS APPLIED FOR: (CHECK BOXES) (FOR DEkT USE ONLY) Master Plan Specific Plan Precise Development Plan Tentative Tract Map Planned Development Permit Non-Residential Planned Development Condominium Permit Special Use Permit Redevelopment Permit Obtain from Eng. Dept Administrative Variance Administrative Permit - 2nd Dwelling Unit General Plan Amendment Local Coastal Plan Amendment Site Development Plan Zone Change Conditional Use Permit Hillside Development Permit Environmental Impact Assessment Variance Planned Industrial Permit Coastal Development Permit Planning Commission Determination List any other applications not spccificed (FOR DEPT USE ONLY) 2) LOCATION OF PROJECT: ON THE (NORTH, SOUTH EAST, WEST) (NAME OF STREET) Dryden Place South SIDE OF BETWEEN Palomar Oaks Way 1 (NAME OF STREET) (NAME OF STREET) 3) BRIEF LEGAL DESCRIPTION: I Carlsbad Tract 81-46, Unit 1, Lots 21 and 22 I 4) ASSESSOR PARCEL NOIS). 212-091-04 and 212-091-05 J 5) LOCAL FACILITIES MANAGEMENT ZONE 8) EXISTING ZONING In/al DESIGNATION 6) EXISTING GENERAL PLAN n/a 7) PROPOSED GENERAL PLAN DESIGNATION 11) PROPOSED NUMBER OF RESIDENTIAL UNITS OF LOTS cl 12) PROPOSED NUMBER pj 13) TYPE OF SUBDIVISION (RESIDENTIAL, COMMERCIAL ,INDUSTRIAL) 14) NUMBER OF EXISTING RESIDENTIAL 1-1 UNITS 15) PROPOSED INDUSTRIAL OFFICElSQUARE FOOTAGE SQUARE FOOTAGE 16) PROPOSED COMMERCIAL LAND USE REvlMI APPUCATION FORM PAGE 2 OF 2 17) PERCENTAGE OF PROPOSED PROJECT IN OPEN SPACE 18) PROPOSED SEWER USAGE IN EQUIVALENT DWELLING UNITS 1-1 19) PROPOSED INCREASE IN AVERAGE DAtLY TRAFFIC I n/a I 20) PROJECT NAME:' Callaway Golf Test Facility Elevator 21) BRIEF DESCNPTION OF PROJEff. I . Addition of elevator and storage areas to first and second floors of existing building. 22) IN THE PROCESS OF REVIEWING THIS APPLICATION IT MAY BE NECESSARY FOR MEMBERS OF CITY STAFF, PMNING COMMISSIONERS, DESIGN REVIEW BOARD MEMBERS, OR CITY COUNCIL MEMBERS TO INSPECI' AND ENTER THE PROPERTY THAT IS THE SUBJECT OF THIS APPUCATION. I/WE CONSENT M ENTRY FOR THIS SIGNATURE 23) OWNER 24) APPLICANT NAME (PRINT OR TWE) NAME (PRINT OR WE) CALLAWAY GOLF SMITH CONSULTING ARCHITECTS MUNG ADDRESS WNG ADDRESS 2285 Rutherford Road 5355 Mira Sorrento Place, Suite 750 ClTT AND STATE ZIP TUEPHONE CrR AND STATE ZIP TUEPHONE FEE COMPUTATION: APPUCA'IlON TYPS FEE REQUIRED r d TOTAL FEE REQUIRED ' DATE FEE PAID I qonod I I 7-20 -75" I RECEIPT NO. I CITY OF CARLSBAD 1200 CARLSBAD VILLAGE DRIVE CARLSBAD, CALIFORNIA 92008 434-2867 REC'D FROM ACCOUNT NO. DESCRIPTION I AMOUNT RECEIPT NO. 16464 ~intcd on recycled paper. NOT VALID UNLESS VALIDATED BY CASH REGISTER , I . , /. j< 2 ' ,i .Ti7 - CITY OF CARLSBAD 1200 CARLSBAD VILLAGE DRIVE CARLSBAD, CALIFORNIA 92008 434-2867 REC'D FROM E ACCOUNT NO. DESCRIPTION 1 AMOUNT NOT VALID UNLESS VALIDATED BY CASH REGISTER ". CITY OF CARLSBAD 1200 CARLSBAD VILLAGE DRIVE CARLSBAD, CnLlFORNlA 92008 434-2867 REC'D FROM DATE /a -/- 75 ACCOUNT NO. DESCRIPTION AMOUNT RECEIPT NO. 25521 NOT VALID UNLESS VALIDATED BY @ ~inted on recycled paper. CASH REGISTER -_ .*. - I___y_I -,' ri. , . . . , I. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 GENERAL INFOR.MATIOP$ A. B. C. D. E. F. G. H. Name, address and telephone number of the applicant, owner and Engineer or Architect who prepared the plan. North arrow and scale. Vicinity map showing major cross streets. Date of preparatiodrevisions. Project Name and Application Types submitted. Name of sewer, water and schwl districts providing service to the project. All facilities labeled as "existing" or "proposed". A summary table of the following: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Street address and assesso~s parcel number. Site acreage. Existing zone and land use. Proposed land use. Total building coverage. JUL 2 0 1995 Building square footage. Percent Landscaping. Number of parking spaces required/provided. Square footage of required employee ea- area. Square footage of proposed employee eating area (intexior and eiterior eating area). FRMm5 1w92 Page 1 of 4 11. ,-verage Daily Traffic generated by the yject broken down by separate bises. 1. 2. 3. 4. 5. 6. 7. a. Approximate location of existing and proposed buildings and permanent structures on site and within 100 feet of site. Location of all major vegetation showing size and type. Location of railroads. Bearings and distances of each exterior boundary line. Distance between buildings and/or structures. Building set backs (front, side and rear). Location, height and materials of walls and fences. Indicate top and bottom and worst condition elevations for all walls and fences at each end and in the middle of the wall. Indicate on site plan improvements and ammenities in the interior/exterior employee eating areas. (Le.? Benches, tables, trash cans etc.) B. Street and Utilities 1. 2. 3. 4. 5. d 7. a. 9. 10. The hation, width and proposed name of all streets within and adjacent to the proposed project. Show street grades and centerline radii. Name, location and width of existing adjacent streets and alleys. Include medians and adjacent driveway locations. mical street cross sections for. all adjacent and streets within project. Width, location, and use of all existing and/or proposed public or private easements. Public and private streets and utilites clearly identified. Show distance between all intersections and dum and high use driveways. Clearly show parking stall and isle dimensions and truck turning radii for all Parking areas. Show access points to adjacent undeveloped lands. Show all existing and proposed street lights and utilities (sewer, water, major gas and fuel lines, major electric and telephone facilities) within and adjacent to the project. Show location of all fire hydrants within 300 feet of site. FRMms 10192 Page 2 of 4 , h '0 0 0 0 0 0 1. 2. 3. 4. 5. 6. C. Grading and I'"~gc Approximate contours at 1' intervals for slopes less than 5%, 2' intd for slopes between 5% and lo%, and 5' intervals for slopes over 10% (both existing and proposed). Existing and proposed topographic contours within a 100 foot perimeter of the boundaries of the site. Fdisting onsite trees; those to be removed and those to be saved; Earthwork volumes; cut, fill, import and export Spot elevations at the cornen of each pad. Method of draining each lot. Include a typical cross section taken parallel to the frontage for lots with less than standard frontage. Location, width and/or size of all watercourses and drainage facilities within and adjacent to the proposed subdivision. Show location and approximate size of any proposed detentionhetention basins. Clearly show and label the 100 year flood line for the before and after conditions for any project which is within or adjacent to a FEMA flood plain. h-n (10) preliminary landscape! plans prepared on 24" x 36" sheet(s) folded to 8 1/2" x 11". A. Landscape zones per the City of Carlsbad Landscape Manual. B. Typical plant species, quantity of each species, and their size for each planting zone (Use symbols). C. An estimate of the yearly amount of irrigation (supplemental) water required to maintain each zone. D. Landscape maintenance responsibility (private or common) for all areas. E. Percent of site used for landscaping. F. Water Conservation Plan. Ten (10) building elevation and floor plans prepared on 24" x 36" sheet(s) folded to 8 1/2" x 11". The Building Elevation and floor plans shall include the following information: k %or plans with square footage included. B. Lacation and size of storage areas. C. AIl buildings, stntctures, walls and/or fences, sips and ataior lights. D. Screening of Toof equipma Show roof parapet and any roof appurtenances (Le., mechanical equipment, ventilating fans etc.) that extend above the parapet.) E. Scale F. Indicate the height on all building elevations. FRMooo5 1w92 Page 3 of 4 0 12. 13. One (1) copy of 8 l/c 11" location map (suggested scale 2(x - vi- maps on the site plan are not acceptable). Environmental Impact Assessment Form (Separate Fee Required). Public Facility Agreement: Two (2) copies: One (1) notarized original and one (1) reproduced copy. (Separate fee required). Three (3) copies of Preliminary Title Report (current within the last six months). One copy of colored elevation Plan. All projects must evaluate their potential impacts on the regional transportation system, including the costs of mitigating the associated impacts, as required by the SANDAG Congestion Management Program (CMP). For projects with an average daily traffic (ADT) generation rate greater than 500 vehicles per day - or 200 or more peak-hour vehicle trips: Submit two (2) copies of a Circulation Impact Analysis for the project The analysis must be prepared by a Registered Traffic Engineer or Registered Civil Engineer. The analysis must show project impacts to all intersections and road segments identified as impacted within the included Local Facilities Management Plan or as otherwise determined in discussions with staff. The following minimum information should be included with the study: a) 8 1/2" x 11" or 8 1/2" x 14" plats showing zone impacted roads, background and project AM and PM peak hour impacts and traffic distriiution. b) Project traffic generation rates and traffic assignment. C) Necessary calculations and/or analysis to determine intersection and road segment levels of service. d) Any proposed mitigation requirements to maintain the public facility standards. e) On Collector streets and above, an analysis of the need or a traffic signal will be required. "Large" projects: Any project which, upon its completion will be expected to generate either an equivalent of 2,400 or more average daily vehicle trips x 200 or more peak-hour vehicle trips, including Luge projects that may have already been reviewed under CEQA but require additional local discretioxmy actions, is defined as a large project" under the SANDAG Congestion Management Program (CMP) and will be subject to enhanced CEQA review as specified in the CMP. Dependins upon the complexity of the project, the City of Carfsbad rcsuye~ the fight to a traffir study on any project Provide color board showing material and color samples of glass, reveals, aggregate, wood etc. Provide roof plans (plan view) indicating the location and height of roof appute-ces, vents, mechanical equipment etc. Completed "project DesaiptioxVExplanation" sheet. Deposit for Publication of Notices - See Fee Schedule for amount. lW92 Page 4 of 4