Loading...
HomeMy WebLinkAboutPIP 97-06; Carlsbad Crest Corporate Center; Planned Industrial Permit (PIP) (15)April 7, 1997 Smith Consulting 2820 Willow Creek, Suite 400 San Diego, CA 921 31 SUBJECT: PRE by-%? - CARLSBAD AIRPORT CENTER - LOT 41 APN: 21 2-092-05 A preliminary review of your project was conducted on April 3, 1997. Listed below are the issues raised by staff. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. The preliminary review does not represent an in-depth analysis of your project. Additional issues of concern may be raised after your application is submitted and processed for a more specific and detailed review. Planning: 1. 2. 3. 4. 5. 6. 7. A 30-foot landscaped setback is required from Camino Vida Roble and Palomar Oaks Way. The proposed project does not meet ordinance parking requirements. Please revise plans to reflect the following parking ratios: Office 1 :250 Manufacturing 1 :400 Warehousing 1:lOOO Spec. Building 1 :250 Provide employee eating areas equal to 300 building area. No parking is permitted within 30-feet of Roble. All loading areas must be screened from Palomar Oaks Way. square feet per 5,000 square feet of Palomar Oaks Way view from Camino or Camino Vida Vida Roble and The project site is located adjacent to Palomar Airport. The proposed project must comply with the Comprehensive Land Use Plan (CLUP) for the airport. Noise impacts to the property are estimated to exceed 75 CNEL on the site. The CLUP for the airport identifies industrial uses as not compatible with noise impacts in excess of 75 CNEL. Revise plans to move buildings out of the 75 CNEL noise contour to the extent possible. Please contact the airport regarding potential airport issues relating to the proposed project, including required FAA permits. An avigation easement will be required on the subject site. Landscaping on the project must comply with the City’s Landscape manual. -.. 2075 Las Palmas Dr. - Carlsbad, CA 92009-1 576 - (61 9) 438-1161 - FAX (1319) 438-0894 @ __ PRE 97-21 - CARLSBAD AIRPORT CENTER - LOT 41 APRIL 7, 1997 PAGE 2 a. All rooftop equipment must be screened from Palomar Oaks Way and Camino Vida Roble. 9. No elevations were submitted for the proposed project. The architecture must comply with the Carlsbad Airport Center Specific Plan design standards. Building designs are to include a variety of building materials and colors, include building architectural accent features and varied building roof heights and roof overhangs. Engineering: 11. 12. 13. 14. This project will require a Minor Subdivision to divide th lots. Additionally, a condition of this Minor Subdivision will be to record a Covenant of Easement to assure that the proposed joint access will be provided and maintained to both lots. The site layout, as proposed, is unable to accommodate truck access and circulation as required by City standards, which require providing access and circulation for a 42’ truck turning radius, in accordance with Figure 407E of the California Department of Transportation Highway Design Manual. If loading docks are to be included with this project, then the site must be able to accommodate a maximum 3-point turn for a standard size passenger vehicle. Dead-end parking aisles with lengths that exceed 150’ are required to have turn- around areas at the aisle terminus to accommodate a maximum 3-point turn for a standard size passenger vehicle. A tangent length of 50‘, measured from the curb face, is required at the proposed driveway access on Camino Vida Roble. Future plans should show the grade of the proposed driveway access on Palomar Oaks Way. The maximum allowed grade is 12% along with sufficient sight distance. Please contact Teresa Woods at (760) 438-1 161 , extension 4447 if you have any questions. Assistafit Planning Director GEW:TW:bk C: Michael J. Holzmiller Bobbie Hoder File Copy Data Entry