Loading...
HomeMy WebLinkAboutPIP 97-07; Newton Business Center; Planned Industrial Permit (PIP) (35)June 25,1997 J. R. Wetsal Industrial Developments International 181 01 Von Karmen Avenue, Suite 1040 Irvine, CA 92612 SUBJECT: PRELIMINARY REVIEW 97-34 - NEWTON DRIVE BUSINESS PARK APN: 21 2-05043 A preliminary review of your project was conducted on June 19, 1997. Listed below are the issues raised by staff. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. The preliminary review does not represent an in-depth analysis of your proiect. Additional issues of concern may be raised after your application is submitted and processed for a more specific and detailed review. Planninq: 1. A Planned Industrial Permit (PIP) and Coastal Development Permit is required for the proposed development and environmental review of the project would be required due to proposed grading and potential disturbance to sensitive habitat located on the site. A biological survey and analysis would be required as part of the application submittal. 2. The configuration of the parcel proposed for development is not shown accurately on the site plan. Please show the property lines of the subject parcel and the adjacent properties. It is impossible to determine setbacks without property lines. 3. To reduce visual impacts and ensure compatibility, the proposed structure should incorporate enhanced architectural elements more similar to an offtce than a warehouse facility due to its location adjacent to future residential development. 4. The required front yard setback is an average of 35’ with a minimum of 25’ in the P- M Zone. The setback, which is measured from the Newton Drive right-of-way line, must be entirely landscaped and irrigated. Required side yard setbacks are 10’ with no parking overhang and the required rear yard setback is 20’ (IO’ of which must be entirely landscaped). 5. The proposed location of the industrial development immediately adjacent to residentially designated property requires a very sensitive design to avoid potential impacts. The proposed loading bays on the west side of the structure (as depicted on the plan) would not be compatible with future residential development. Please orient the building so that the loading bay faces the industrial area and ensure that a 2075 Las Palmas Dr. - Carlsbad, CA 92009-1 576 - (61 9) 438-11 61 - FAX (G19) 438-0894 @ - PRE 97-34 - NEWTON Dt,,\/E BUSINESS PARK JUNE 25,1997 PAGE 2 6. 7. 8. 9. solid landscape screen ’is provided to screen loading areas and the parking lot from surrounding properties. The project could be subject to conditions of approval which restrict hours of operation and noise levels to ensure compatibility with surrounding residential development. A minimum of three hundred square feet of outdoor eating area is required for each 5,000 square feet of building area. (50% of the required area may be provided inside). Employee eating areas are not shown on the plan. The parking standard for office and warehouse uses is as follows: Office: 1 space/250 square feet of gross floor area Warehouse: 1 space11 ,000 square feet of gross floor area The floor plan must reflect the areas to be used for each use or the project should be parked at the office standard (1 space/250 square feet). Standard parking spaces are 8.5’ x 20’ and compact spaces are 8’ x 15’. No overhang is permitted within any required setback for standard spaces and no overhang is permitted for compact spaces. Please show the dimensions on site plans submitted for review. Ennineerinn: 1. 2. 3. 4. 5. 6. 7. .. Please indicate all existing and proposed utilities (i.e., storm drain, water, sewer, etc.) for on-site and off-site along Newton Drive to Faraday Avenue. Indicate gravity flow sewer facilities with inlet elevations. Show on-site surface runoff draining towards Newton Drive. The proposed cul-de-sac design does not meet City design standards. Any and all required street improvements must meet City Standards. Please be advised, in accordance with Item No. 2 above, depending on property boundary, project design and traffic circulation patterns, construction of a full standard cul-de-sac, with any requisite off-site property acquisition and improvements, may be required. Delete any proposed parking spaces that are directly adjacent to a proposed driveway. Delete the proposed parking space which is being shown directly adjacent to the proposed gate. Provide a Vicinity Map on the site plan. Submit the site plan at either a 1” = 40’, or, 1” = 20’ scale. The preliminary drainage study which was submitted (Bartolome J. Pastor of ALTA Consultants, correspondence to C. Wickham, dated: May 7, 1997) indicates the following: e PRE 97-34 - NEWTON DI ..JE BUSINESS PARK JUNE 25,1997 PAGE 3 8. 9. IO. 11. 12. 13. 14. 15. a) The existing 18”’storm drain in Newton Drive is not of sufficient size to handle the additional flow from the proposed development; and, b) all manholes and inlets in Newton Drive, and south of Newton Drive along Faraday Avenue, will overtlow. City Standards require the following: Drainage facilities shall be designed to carry the IO-year, 6-hour storm underground, the 50-year, 6-hour storm between the tops of the curb lines, and, the 100-year, 6-hour storm between the right of way. This project will be required to meet this standard design criteria. This may include installation of additional inlets/storm drain, pressure pipe and/or on-site retention. Are the proposed slopes, on or off-site. If they are located off-site, a private slope easement must be obtained from the adjacent property owner. As previously indicated (Assistant Planning Director, Gary Wayne, correspondence to SPT Holdings, LLC, dated: April 3, 1997), one (1) 30’ wide driveway is acceptable for this proposed project. If two (2) driveways are going to be proposed, depending on property boundaries, the second driveway must be a 36’ wide (not 40’) shared driveway, with the adjacent property. As previously indicated (Assistant Planning Director, Gary Wayne, correspondence to SPT Holdings, LLC, dated: April 3, 1997), adequate queuing area must be shown at the driveway entrances. Where gates are proposed, 20’ of queuing must be provided for each 1000 Average Daily Traffic (ADT). Additionally, turning areas must be provided before the gate so that a standard “P” vehicle can turn around on-site without backing into, or, utilizing the public street. Indicate all existing and proposed improvements. Show typical street sections for Newton Drive and Faraday Avenue. Indicate existing and proposed improvements on the typical sections. Dimension the site plan. Drive aisles must have a minimum width of 24’. Unless they are adjacent to a parallel loading area, then the drive aisle must have a minimum width of 32’. Please. indicate the amount of grading proposed for the project in cubic yards of cut/fill and importlexport. A recent Preliminary Title Report (PR) (issued within 6 months of formal application submittal) will be required for the proposed project. PRE 97-34 - NEWTON Dh. JE BUSINESS PARK JUNE 25,1997 PAGE 4 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. All easements and encumbrances as identified in Schedule "B" of the PR must be indicated on the site plan. The future disposition of any easements and encumbrances must also be identified. The complete property boundary must be shown on the site plan, which must include all bearings and distances. All property areas must be identified as proposed or future development, or, as areas of open space. Please indicate 42' (CalTrans 407-E) and 60' (CalTrans 407-D) turning radii for the proposed 12' x 14' "drive-in door" and "truck courtyard," respectively. Indicate how a 60' radius truck will circulate throughout the site to the loading areas. Please be advised, truck circulation throughout the site is a major staff issue of concern. Indicate how National Pollutant Discharge Elimination System (NPDES) criteria will be met. This could include, but not be limited to, doing one or a combination of the following: directing surface run-off through vegetated swales prior to discharge to a storm drain or the public right of way, constructing a gravel/sand/fossil filter system, constructing depollutant basins, etc. Also, any loading areas that are located in a sump must have pump facilities to direct drainage to a pollutant mitigation area. Show all existing and proposed topography and drainage patterns for the site. Please be advised, this property may be located in College Boulevard Assessment District 85-2. This can be verified with the PR for the property. Please be advised, this property is located in the Cannon Road West Facility Fee Area of Benefit. Therefore, the applicant will be required to sign a consent and waiver agreement for payment of a facilities fee, as well as, pay the facilities fee, prior to any building permits being issued on the property. The current rate for this fee is $73/ADT, and is subject to change. Indicate future access from Newton Drive to any and all other developable lots in the vicinity of the project (e.g., APN's: 212-050-41 , 36-39). Please provide 5' offsets at proposed parking stalls which are located at 90° adjacent to each other. Indicate the project's proposed ADT, on the site plan. The preliminary site plan indicates the area for the site as 9.58 ac. The assessor's parcel book indicates the site area as 14.28 ac. Please verify and revise. This preliminary review does not constitute a complete review of the proposed project, additional items of concern may be identified upon formal project application submittal. ~ ~~~~ P PRE 97-34 - NEVVTON Dh! 4 E BUSINESS PARK JUNE 25,1997 PAGE 5 28. A red-lined check print is enclosed for the applicants use in making the requested revisions. This check print must be returned with the formal application submittal to facilitate continued staff review. Please contact Anne Hysong at (760) 438-1 161, extension 4477, if you have any questions. Assistant Planning Director GRN:AH:kr C: Michael J. Holzmiller Bobbie Hoder Don Neu File Copy Data Entry