HomeMy WebLinkAboutPIP 98-01; Palomar Crest Corporate Center; Planned Industrial Permit (PIP) (2)City of Carlsuad 98073 Fire Department a Bureau of Prevention Plan Review: Requirements Category: Fire Conditions Date of Report: Thursday, March 5,1998 Reviewed by: hi PpJ Contact Name Greg Fisher I ', , -. . ,'% Address / City, State CA .. .' ,. . ; i. ! Bldg. Dept. No. Planning No. PiP98-01 Job Address Loker Ste. or Bldg. No. Approved - The item you have submitted for review has been approved. The approval is based on plans; information and/or specifications provided in your submittal; wd therefore any changes to these items after this date, including field modifica- tions, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. 0 Disapproved - Please see the attached report of deficiencies. Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. For Fire Depattment Use Only Review 1 st 2nd 3rd CFD Job# 98073 File# Other Agency ID 1 1 2560 Orion Way Carlsbad, California 92008 (619) 931-2121 .. . 7 Requirements Caregory Fire Conditions -. 98073 Deficiency Item: P e n d I n g 01 Building Permits Prior to the issuance of building permits, complete building plans shall be approved by the Fire Department. $ Proposed language: Prior to issuance of building permits, the Fire Department shall evaluate building plans for conformance with applicable fire and life safety requirements of the state and local Fire Codes. Deficiency Item: P e n d i n g 02 Hydrants Additional on-site public water mains and fire hydrants are required. Proposed change for Industrial and multi family: Provide additional public fire hydrants at intervals of 300 feet along public streets and private driveways. Hydrants should be located at street intersections when possible, but should be n 100 feet from terminus of a street or driveway. te 1 Deficiency Item: P e n d i n g 03 Site Plan/Hydrants Applicant shall submit a site plan to the Fire Department for approval, which depicts location of required, proposed and existing public water mains and fire hydrants. The plan should include off-site fire hydrants within 200 feet of the project. Deficiency Item: P e n d i n g 04 Site plan/access Applicant shall submit a site plan depicting emergency access routes, driveways and traffic circulation for Fire Department approval. I Deficiency Item: P e n d i n g 05 Access during construction An all weather, unobstructed access road suitable for emergency service vehicles shall be provided and maintained during construction. When in the opinion of the Fire Chief, the access road has become unserviceable due to inclement weather or other reasons, he may, in the interest of public safety, require that construction operations cease until the condition is corrected. Deficiency Item: P e n d i n g 06 Combustible construction materials on site All required water mains, fire hydrants and appurtenances shall be operational before combustible building materials are located on the construction site. I I I [ Deficiency Item: P e n d i n g 08 Fire lanes Prior to building occupany, private roads and driveways which serve as required access for emergency service vehicles shall be posted as fire lanes in accordance with the requirements of section 17.04.020 of the Carlsbad Municipal Code. I I Page 2 Mar 5,1998 + ,t Requirements Category" Fire Conditions - 98073 Deficiency Item: P e n d i n g 10 Fire protection systems- sprinklers, alarms, standpipes Plans and/or specifications for fire alarm systems, fire hydrants, automatic fire Sprinkler systems and other fire protection systems shall be submitted to the Fire Department for approval Prior to construction. Proposed language All buildings having an aggregate floor area in excess of 10,000 square feet must be protected by automatic fire sprinkler systems. Plans and specifications must be approved by the fire department, and a permit obtained prior to installation. Proposed multifamily residential buildings must be protected by fire alarm systems. Plans and specifications must be approved, and a permit obtained prior to installation. Deficiency Item: P e n d i n g 11. Sprinklers required for buildings over 10,000 sq ft in area An approved automatic fire sprinkler system shall be installed in buildings having an aggregate floor area exceeding 10,000 square feet. Delete Page 3 03/05/98