Loading...
HomeMy WebLinkAboutPIP 98-05; Cornerstone Corporate Center; Planned Industrial Permit (PIP) (9)July 13, 1998 TO: VAN LYNCH, ASSISTANT PLANNER FROM: Associate Engineer Quon CONDITIONS TRANSMITTAL CORNERSTONE CORPORATE CENTRE - BUILDING A, PIP 98-05 The Engineering Department has completed its review of the subject project. The Engineering Department is recommending that the project be approved subject to the following conditions: General 38. Prior to issuance of any building permit, the developer shall comply with the requirements of the City’s anti-graffiti program for wall treatments if and when such a program is formerly established by the City. 46. Prior to hauling dirt or construction materials to or from any proposed construction site within this project, the developer shall submit to and receive approval from the City Engineer for the proposed haul route. The developer shall comply with all conditions and requirements the City Engineer may impose with regards to the hauling operation. FeeslAnreements 50. The developer shall pay all current fees and deposits required. 56. Prior to approval of any grading or building permits for this project, the owner shall give written consent to the annexation of the area shown within the boundaries of the subdivision plan into the existing City of Carlsbad Street Lighting and Landscaping District No. 1 on a form provided by the City. + Prior to issuance of building permit, the applicant shall provide documentation, to the satisfaction of the City Engineer, of a reciprocal easement with the adjacent lot to the south for ingress, egress, circulation, and drainage, including provisions for maintenance and liability. Grading 61. No grading for private improvements shall occur outside the limits of the project unless a grading or slope easement or agreement is obtained from the owners of the affected properties and recorded. If the developer is unable to obtain the grading or slope easement, or agreement, no grading permit will be issued. In that case the developer must either amend the site plan or modify the plans so grading will not occur outside the project site in a manner which substantially conforms to the approved site plan as determined by the City Engineer and Planning Director. Dedicationsllmprovements 70. The developer shall comply with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The developer shall provide best management practices as referenced in the "California Storm Water Best Management Practices Handbook" to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer. Said plans shall include but not be limited to notifying prospective owners and tenants of the following: a. All owners and tenants shall coordinate efforts to establish or work with established disposal programs to remove and properly dispose of toxic and hazardous waste products. b. Toxic chemicals or hydrocarbon compounds such as gasoline, motor oil, antifreeze, solvents, paints, paint thinners, wood preservatives, and other such fluids shall not be discharged into any street, public or private, or into storm drain or storm water conveyance systems. Use and disposal of pesticides, fungicides, herbicides, insecticides, fertilizers and other such chemical treatments shall meet Federal, State, County and City requirements as prescribed in their respective containers. c. Best Management Practices shall be used to eliminate or reduce surface pollutants when planning any changes to the landscaping and surface improvements. 75. The structural section for the access aisles must be designed with a traffic index of 5.0 in accordance with City Standards due to truck access through the parking area and/or aisles with an ADT greater than 500. The structural pavement design of the aisle ways shall be submitted together with required R-value soil test information and approved by the City as part of the building site plan review. Code Reminder The project is subject to all applicable provisions of local ordinances, including but not limited to the following: 79. If you 4380. The developer shall exercise special care during the construction phase of this project to prevent offsite siltation. Planting and erosion control shall be provided in accordance with the Carlsbad Municipal Code and the City Engineer. have questions regarding any of the comments above, please contact me at extension KENNETH W. QUON Associate Engineer C: Public Works Director Bob Wojcik, Principal Civil Engineer