Loading...
HomeMy WebLinkAboutPS 00-114; Net Synergy at Carlsbad Corporate Plaza; Sign Permits/Programs (PS). City of Carlsbad 2075 Las Palmas Drive Carlsbad, CA 92009 (619) 438-1 161 SIGN PROGRAM FEE RECEIPT NO. PLANNING DEPARTMENT REVIEW FOR SIGN PERMITS All plans submitted for sign permitdsign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access pdints to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding signs. 5. Provide an elevation for all proposed signs which specifies the following: A. B. C. Proposed sign copy. Dimensions and area for all existing and proposed signs. Materials the sign(s) will be constructed of. APPLICANT MUST SUBlMT THREE (3) SETS OF SIGNBITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. Average processing Time: 2 weeks NAME OF PROJECT: Carlsbad Corporabe Plaza ADDRESSOFPROJECT: 6183 & 6185 PaSeO Del Norbe, Carlsbad, CA 2110401800 ASSESSOR PARCEL NUMBER. RELATED PLANNING CASE NUMBER(S): SIGN TYPE: (a) Commercial (b) Industrial (c) Residential (d) Real Estate (e) Freeway (f) Marquee (g) Community identity (h) Service Stn. Prices (i) Campaign PS99-49 SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes No - SPECIFIC PLAN NUMBER VILLAGE REDEVELOPrnT AREA Yes - No - **REQUIRES VR APPROVAL SIGN ORDINANCE: Yes - No - COASTAL ZONE: Yes - No -/COASTAL PERMIT Yes - No - FRMOOOlO 2/96 Page 1 of 2 ~~ ~~ EXISTING SIGNS: Number - Size (in square feet) - - (a) Pole (b) Monument I c- - (c) Wall 3 PERMITS ISSUED FOR EXISTING SIGNS: Yes No - Date TOTAL BUILDING STREET FRONTAGE 1 ft. TOTAL SIGNAGE ALLOWANCE I sq. ft. EXISTING SIGNAGE (SQ. FT.) sq. ft. REMAINING SIGN ALLOWANCE AT PRESENT sq. ft. PROPOSED SIGNAGE (SQ. FT.) 49 809 sq. ft. REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN sq. ft. OWNER I APPLICANT NAME (PRINT OR TYPE) Carlsbad Corporate LLC NAME PRINTORWE) SignMatrix, Inc. d Charlaine Architectural Signage MAILING ADDRESS c/o business Real Estate Mgmt.CO. 6183 Padeo Del Norte, #280, MAILING ADDRESS 8815 Production Avenue CITY AND STATE ZIP TELEPHONE Carlsbad, CA 92009 760-931-1134 ~___ CITYAND STATE ZIP TELEPHONE $an DIego, CA 92121 858-566-8868 I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORREfl TO THE BEST OF MY KNOWLEDGE I CERTIFY THAT 1 AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT W THE ABOVE INFORMATION IS TRUE AND CORRECT M THE BEST OF MYKNOWLEDGE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. 4. Location: In right-of-way Style consistent with Sign Program and/or Specific Plan criteria, if applicable. In visibility triangle at comer On roof 5. Pole and monument signs to be checked by Bob Johnson, Traffic Engineer, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: Date: a FRMOOOlO 8/92 Page 2 of 2 City of Carlsbad 1635 Faraday Avenue Carlsbad CA 92008 Applicant: CHARLAINE ARCHITECTURAL Description PS000114 S I GNAGE Receipt Number: ROO15457 Transaction Date: 09/29/2000 Pay Type Method Description Amount Payment Check 8172 30.00 --__-___-- __________ ________________ __________ Transaction Amount: 30.00 SIGN TYPE A-2 QUANTITY: ONE (1) SET OF LETTERS & LOGO FOR EXTERIOR SOUTH ELEVATION. SPECIFICATIONS: LETTERS: 3/4l THICK CUT OUT ALUMINUM PRIME AND PAINT #41-33 VOC 281-313 DARK BRONZE. COPYRElTERSTYLE: AS SHOWN. PIN MOUNT WITH 1/8" PROJECTION APPROX 14-0l FROM GRADE TO SIGN LOCATION ALUMINUM PRI TO BE OPEN TO 281-313 DARK B I\ NERATED VINYL - RAPHIC LINES w,de DE TO SIGN LOCATION. NETSY NERGY JOB NAME NETSYNERGY - R FILE -&IT 4WLE DATE DESCRIPnON APPROVAL: OOKasis @K with corrections or changes as noted. 0 Make corrections/changes as indicated and show revised. (After any applicable corrections are made, your SI nature releases Charlaine Architectural tignage from res&on:ibility for errors appearing on this su mittal that may be discovered after job is completed.) APPROED: p51GNA~UKl?/DATE . .- TYPICAL HALO / REVERSE CHANNEL LETTER ATTACHMENT i -I #, 8 screw & nylon anchers -. t- -I I