HomeMy WebLinkAboutPS 00-14; Fred Meyer Jewelers; Sign Permits/Programs (PS)City of Carlsbad
2075 Las Palmas Drive
Carlsbad, CA 92009
(619) 438-1 161
PlANNING APPLICATION # 75.- 1q
REX'D BY Dl-a DATE Z/3lOD
SIGN FEE 30.06
SIGN PROGRAM FEE
RECEIPT NO.
PLANNING DEPARTMENT
REVIEW FOR SIGN PERMITS
All plans submitted for sign permitdsign programs shall consist of a minimum of a site plan and sign
elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to
the property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding signs.
5. Provide an elevation for all proposed signs which specifies the following:
A.
B.
C. Proposed sign copy.
Dimensions and area for all existing and proposed signs.
Materials the sign(s) will be constructed of.
APPLICANT MUST SUBMJT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE.
Average processing Time: 2 weeks
NAME OF PROJECT: F@D MLCfkZ bLd5
ADDRESSOFPROJECT: xzs Lx g.'QBL *I67
ASSESSOR PARCEL NUMBER: !cih 50 2 -87
RELATED PLANNING CASE NUMBER(S):
SIGN TYPE: (a) Commercial (b) Industrial (c) Residential
(d) Real Estate (e) Freeway (f) Marquee
(g) Community identity (h) Service Stn. Prices (i) Campaign
SIGN PROGRAM AND/OR
SPECIFIC PLAN CRITERIA
VILLAGE REDEVELOPMENT AREA Yes - No - **REQUIRES VR APPROVAL
SIGN ORDINANCE:
COASTAL ZONE:
Yes - No - SPECIFIC PLAN NUMBER
Yes - No -
Yes - No -/COASTAL PERMIT Yes - No -
FRMOOOlO 2/96 Page 1 of 2
.. EXISTING SIGNS: Number - Size (in square feet)
OWNER
(a) Pole - (b) Monument -
(c) Wall -
APPLICANT
PERMITS ISSUED FOR EXISTING SIGNS: Yes - No - Date
I/ SIGNATURE DATE
TOTAL BUILDING STREET FRONTAGE ft.
TOTAL SIGNAGE ALLOWANCE sq. ft.
EXISTING SIGNAGE (SQ. FT.) sq. ft.
REMAINING SIGN ALLOWANCE AT PRESENT sq. ft.
PROPOSED SIGNAGE (SQ. FT.) sq. ft.
REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN sq. ft.
SIGNATURE DATE
11 NAME (PRINT OR TYPE1 NAME (PRINT OR TYPE)
11 CITY AND STATE ZIP TELEPHONE I CITY AND STATE ZIP TELEPHONE
I CERTIFY THAT 1 AM THE LEGAL OWNER
AND THAT ALL THE ABOVE INFORMATION
MY KNOWLEDGE
IS TRUE AND CORRECT TO THE BEST OF
I CERTIFY THAT I AM THE REPRESENTATIVE OF THE
LEGAL OWNER AND THAT ALL THE ABOVE
INFORMATION IS TRUE AND CORRECT TO THE BEST OF
MY KNOWLEDGE
It I
PLANNER CHECK LIST: RECeNED
1. Field check by planner.
2. Within maximum length, area.
FEB 0 3 2000
3.
4. Location: In right-of-way
Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
In visibility triangle at comer
On roof
5. Pole and monument signs to be checked by Bob Johnson, Traffic Engineer, for visibility issues.
6. When approved route copy to Data Entry
APPROVED: Planner: Date: 7-7do
FRMOOOlO 8/92 Page 2 of 2
City of Carlsbad
1635 Faraday Avenue Carlsbad CA 92008
Applicant: INTEGRATED SIGN ASSOCIATES
Description
PS000014
Amount
9081 02/03/00 0001 01 02
30.00 C-PRMT 30.00
Receipt Number: ROO09714
Transaction Date: 02/03/2000
Transaction Amount: 30.00
GENERAL NOTES:
1. Sign tu be wnstrwted of incombustible materials, and approved
2. Structural steel shall conform tu A.S.T.M. A.36.
3. Steel pipe shd wnform to A.S.T.M. A.53-B or A.P.I. SL-B.
4. All welding by certified welders in shop of licensed fabriutor.
5. Concrete tu be 1:2 1/2:31/2 with 71/2&. water max per bag
6. Auconncctions 1/2“dia. boltsexceptasnuted. Edgedearanwfor
7. Contractor to veri@ all dimensions and wnditbns onjob.
8. U.L. label affixed.
9. ~nstall diswnnect switch.
10. A[[ metd surfices tu have non-corrosive finith.
11. 5quaretubesteels~~wnfurm toA.S.T.M.AS01.
acrylic pkttic (I/# min.).
of cement. Required strength at Z& days. ZOOOPSI.
bolts shd wnform to A.I.S.C. specifications.
RETAINERS 4
3/8” X 3 1 /2” LAGS
FLOURESCENT LAMPS
PUSHED-THRU
ACRYLIC LETTERS
BALLAST
1 1/2”X 1 1/2X3/1Gt1ANGLES -
ALUMN UM FACE 4
I SHEET9 1
WOOD CONSTRUCTION
WALL- PLASTER FACING
SINGLE FACED WALL SIGN DETAIL (FLOURESCENT LIGHTING ONE LINE OF COPY)
NOT TO SCALE
I I GENERAL NOTES:
1. Sign to be wnstructed of incombustible materials, and approved
2. Structural steel shall conform to A.S.T;M. A.36.
3. Steel pipe shall wnform to A.S.T;M. A.53-B or A.P.I. SL-B.
4. All welding by certified welders in shop of licensed fabricator.
5. Concrete to be 1:2 1/2:31/2 with 71/2pk. water m per bag
6. All wnnections 1/2" dia. bolts wept as noted. Edge chance for
7. Contractor to verify all dimensions and conditions onfob.
(1. U.L. label am.
9. Instdl diwnnect switch.
10. MI metal surfacer to have non-corrosive finish.
11. Square tube steel shall conform to A.5.T.M Mol.
acrylic plastic (1/8" min.).
of cement. Required strength at ~8 days. ~0c)c)PsI.
bolts sM1 wnform to A.1.S.C. specifiutiuns.
1 /2" ACRYLIC LETTERS
W/3/1G" Cff EMETAL LAMINATED
FACE ATTACffEV TO WALL WITff
STUDS &SILICONE
3/1G"STUVS, 4" LONG
AVERAGE (4) PER LETTER
- WALL
TYPICAL NON-ILLUMINATED FABRICATED PLASTIC LETTER DETAIL
NOT TO SCALE