HomeMy WebLinkAboutPS 00-41; No Fear; Sign Permits/Programs (PS)City of Carlsbad
1 635 Faraday Avenue
Carlsbad, CA 92008
(760) 602-4600
PLANNING PG W-Y 1
REC'D BY AM
DATE
SIGN FEE
4" Y c_n -0
SIGN PROGRAM FEE c
RECEIPT NO.
f0 /
REVIEW FOR SIGN PERMIT
Planning Department
All plans submitted for sign permitdsign programs shall consist of a minimum of a site plan and sign
elevations containing the following information:
1. North arrow and scale.
2.
3.
4.
5.
Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
Location of all existing and proposed signs for the property.
Distance to the property line(s) for all proposed freestanding sign(s).
Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE.
The awlication must be submitted Drior to 4:OO D.m. Average processing time: 2 weeks
NAMEOFPROJECT: N/o fc
ADDRESS OF PROJECT: 5cao PvQCpb dJ &;.t (07
ASSESSOR PARCEL NUMBER: 3 I Iaaa- aa
RELATED PLANNING CASE NUMBER(S):
SIGNTYPE: &aG (b) Industrial (c) Residential
(d) Real Estate (e) Freeway (f) Marquee
(g) Community identity (h) Service Stn. Prices (i) Campaign
SIGN PROGRAM AND/OR
SPECIFIC PLAN CRITERIA Yesm No [7 Specific Plan Number
VILLAGE REDEVELOPMENT AREA Yes No 0 Requires VR Approval
SIGN ORDINANCE: Yeso NO 0
COASTAL ZONE:
.......................................
Page 1 of 2 Form10 01/00
EXISTING SIGNS: Type Number Size (In Square Feet) d+- (a) Pole
PERMITS ISSUED FOR EXISTING SIGNS: Yes [7 No 0 Date
TOTAL BUILDING STREET FRONTAGE
TOTAL SIGNAGE ALLOWANCE
EXISTING SIGNAGE (SQ. FT.)
Bed sq. ft. -e sq. ft.
REMAINING SIGN ALLOWANCE AT PRESENT €3 sq. ft.
PROPOSED SIGNAGE (SQ. FT.) fa .7>- sq. ft.
REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN $?.a>- sq. ft.
OWNER II
11 NAME (PRINT OR TYPE)
LING ADDRESS
TELEPHONE
P acct
wc 1- SZboO
WJW-Et CITY AND STATE ZIP
I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND
CORRECT TO THE BEST OF MY KNOWLEDGE
II [ SIGNATURE DATE
APPLICANT
NAME (PRINT OR TYPE) 7A- Jl. a‘ L!*
J 7Y70dy74
MAILING ADDRESS
CITY AND STATE ZIP TELEPHONE
CL %?pi, 90 F-LX’-/o 6
1 CERTIFY THAT I AM THE REPRESENTATIVE OF THE
LEGAL OWNER AND THAT ALL THE ABOVE INFORMA-
TION IS TRUE AND CORRECT TO THE BEST OF MY
KNOWLEDGE
r SIGNATURE DATE
PLANNER CHECK LIST:
1. Field check by planner.
2. Within maximum length, area.
3.
4. Location: *:* In right-of-way
Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
In visibility triangle at comer *:*
*:* On roof
5. Pole and monument signs to be checked by Bob Johnson, Traffic Engineer, for visibility issues.
6.
APPROVED: Planner: Date:
When approved route copy to Data E
*********t~**********t**~t*ttt**t***t** Form 10 01/00 Page 2 of2
I
I APPROVED BY I DATE 1 PLANNING
i BUILDING I I
Pllll rpl" cp c
I I I
'*7 i
BUILDING SIGNAGE
PRODUCE (1) INTERNALLY lLLUMINATED/HALO-ILLUMINATED ,090 ALUMINUM LETTERBOX
POWDER-COATED BLACK W/ 3/16" WHITE LEXAN PUSH-THROUGH LETTERS & LOGO.
CALON II #25 SUNFLOWER YELLOW TRANSLUCENT VINYL SURFACE APPLIED
TO LOGO PRODUCING YELLOW ILLUMINATION. SIGN IS MOUNTED 2" OFF THE BUILDING
FACIA PRODUCING WHITE HALO-ILLUMINATION.
MOUNTED TO ALUMINUM CAN
CRODUCINB
HALO-ILLUMINATION
BUILDING 1200 ELEVATION = WEST
SCALE: 1/4” = 1 ’ - 0”
I
1 0’- 1 0” 1
1 I
“STORE FRONT”
NEON & INSTALLATION
! ! ! !
!
! ! ! ! ! /I ! [
\I ! ! ! !
! ! ! ! !
! ! ! ! ! !
! !
!
!
-
- -- -
S P E C I FI CAT1 0 N S
NTERNALLY I LLU MI NATED/HALO-ILLU MI NATED LETTERBOX
VOTE: ALL BUILDING PENETRATION TO BE SEALED WATERTIGHT.
UL 5TlCKER5 CONCEALED FROM VIEW (TOP OF D15PLAy)
5TUD WALL
SHEET METAL
RACEWAY 1
CONDUIT\ \----
TO POWER
electrical to be
brought to sign
by others
TRAN5FORMER //
disconnect switch on
outside of raceway
FLEX CONDUIT
\\
c
c
\
3/8" LEXAN
PU 5 H -TH KOUGH
LETTER5 - NEONTUBES
"ALL CONDUIT & STAND-
OFF5 MUST BE PAINTED
TO MATCH BUILDING FACIA
DOUBLE BACK W/
ELECTROBIT HOUSINC
!
I ! ! ! ! ! ! ! ! \
! !
-U.L. APPROVED \ LEXAN BACK5
REQUIRED
ALUM. RETURN5
& FACIA PAINTED
BLACK
W/ GTO WIRING "WEEPS IF REQUIRED
MU51 BE BAFFLED
TO PREVENT LIGHT LEAKAGE
r( 0 '0 .
4 0 d e
e N N
a N
0 4
..
0 0 \ d 0 \ e 0
CARLSBAD COMPANY STORES
A I- OF.