Loading...
HomeMy WebLinkAboutPS 00-71; Plastic Surgeon Skin Care; Sign Permits/Programs (PS)City of Carlsbad 1 63 5 Faraday Avenue Carlsbad, CA 92008 (760) 602-4610 SIGN PROGRAM FEE RECEIPT NO. I90 17-v DATE RECEIPTNO. 0 17- REVIEW FOR SIGN PERMIT Planning Department All plans submitted for sign permitshign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the ,property. 3. Location of all existing and proposed signs for the property. 4. 5. Distance to the property line(s) for all proposed freestanding sign(s). Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGNBITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The aDuiication must be submitted Drior to 4:OO D.m. Average processing time: 2 weeks NAME OF PROJECT: ADDRESS OF PROJECT: ASSESSOR PARCEL NUMBER: 2’03 J~z-/C-~D RELATED PLANNING CASE NUMBER@): SIGN TYPE: (a) Commercial (b) Industrial (c) Residential (d) Real Estate (e) Freeway (0 Marquee (g) Community identity (h) Service Stn. Prices (i) Campaign ’ SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yeso No a Specific Plan Number VILLAGE REDEVELOPMENT AREA Yes651 No 0 Requires 100 SIGN ORDINANCE Yeso NO COASTAL ZONE: YesQ No 0 CoastalPennit Yes 0 No ***t***~*t******t******t**,**,.4**t******* Form 10 01/00 Page 1 of2 EXISTING SIGNS: Type Number Size (In Square Feet) (a) Pole 0 (b) Monument 0 . (c) Wall 0 PERMITS ISSUED FOR EXISTING SIGNS: Yes 0 No 0 Date d/ (sc TOTFLL BUILDING STREET FRONTAGE 33 5 ft. TOTAL SIGNAGE ALLOWANCE 33s sq. ft. EXISTING SIGNAGE (SQ. FT.) 0 sq. ft. REMAINING SIGN ALLOWANCE AT PRESENT 330s sq. ft. PROPOSED SIGNAGE (SQ. FT.) 3.1. '3 sq. ft. REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN cg sq. fi. I1 OWNER I APPLICANT RINT OR TYPE) 4?6A a;%-A* LLhL MAILING ADDRESS MAILING ADDRESS TELEPHONE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. in visibility triangle at comer ' 4. Location: *:* In right-of-way *:* 0:. On roof 5. Pole and monument signs to be checked by Bob Johnson, Traffic Engineer, for visibility issues. 6. When approved APPROVED: Planner: Date: **********************t****t********.*** Form 10 01/00 Page 2 of 2 Address: . 2907 Carlsbad Blvd, Carlsbad, CA92008 APN: 203-232- 15-00 Legal: Parcel 8, Block 8 & 9, Map 368, County of San Diego ’SITE ___~ ~ GRAND AVENUE -I I Illuminated Slgnage, Installed -_ __ 235 Engcl Street, Escondido, CA 92029 760.737.74 14 Client- __ - - fax 760.737.7418 Scale-- __ Dale n lhh dfawlng on4 Iho concopls II rcprrronls ow the sole ornrlv 1 0'-0" Continous "L" bracket (at top and bottom of raceway) mounted to wall with #10 screws, Raceway behind oval aluminum background panel Halo illuminated aluminum logo panels with custom fade on faces, stud mounted. Neon tube into PK fitting. Fade from blue (PMS 2945) to white, Halo neon is "Sparkling Blue". Blue (PMS 2945) painted letters on white panel. Cut-out aluminum letters, painted, stud mounted, Transformer mounted in raceway with UL approved disconnect switch. I Section Illuminated Logo Signage: Plastic Surgeon Skin Care Cut out aluminum lettering with reverse halo logo elements. 3/4% 1 '-0" 1 275 Sq, Ft, I