Loading...
HomeMy WebLinkAboutPS 04-117; Charles Schwab; Sign Permits/Programs (PS)City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-4600 SIGN FEE SIGN PROG- RECEIPT NU. REVIEW FOR SIGN PERMIT Planning Department AI1 plans submitted for sign permjts/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1, North mow and scale. 2. 3. 4. 5. Location of Cxistmg buildings or structures, parlung areas, and vehicular access points to the ProPCrty, Location of all existing and proposed signs for the property. Distance to the property line(s) for all proposed freestanding sign(s). Provide an elevation €or all proposed sign($ which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGNISITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The n~aliration must be submitted orior to 4:OO p.m. Average processing time: 2 weeks NAME OF PROJECT: M- h ADDRESS OF PROJECT: a 3 90 f ASSESSOR PARCEL MJMBER: - RELATED PLANNING CASE NUMBER(S): TYPE OF DEVELOPMENT: (a) Residential (e) Service Station (i) Public Park (f) Prof. care (j) Produce Stand (g) Theater (k) NUNry (h) Govu'Church (1) P-U/OS Zone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA YJJ NO 0 Specific plan Number COASTAL ZONE: Yeso No 0 Pale Monument Wall EXISTING SIGBS: ~ ~- (a) 13 Sr, FT elk" i MAXIMUM SIGN AREA rTYFE I NUrMBER 1 SIGN AREA 11 SIGNHEIGHT PROPOSED MAXIMUM PROPOSED SIGN SIGN 1 SIGN AREA HEIGHT HEIGHT TYPE MAWMUM NUMBER (MAXIMUM ~ NUMBER PROPOSED SIGN ALLOWED AREA ~ - Canopy Freestandlng (Proled Identity) PROPOSED MAXIMUM PROPOSED' SIGN SIGN SIGN AREA HEIGHT HEIGHT - PERMITSISSUEDFOREXISTINGSIGNS: Yes No Date PROPOSED PERMANENT SIGNS: Construction MAXIMUM I hWMBER PROPOSED Monument Suspended Freestanding (Project Identity) For Sale Banner I 8oo/zoo @ aue-~a-aee4 02?11 Pn VESE~ P. 02 I City of Carlsbad 1635 Faraday Avenue Carlsbad CA 92008 Applicant: TURNER TOM Description PS040117 Amount 40.00 Receipt Number: ROO44403 Transaction Date: 08/12/2004 Transaction Amount: 40.00 8/9/2004 11:52AM Structural Engineering Calculations for: Charles Schwab 2390 Faraday Ave Carlsbad, California Monument Sign, 3-0" OAH Index Title .................. 1 Specifications ................. .2 Wind Loads .................. 3 Steel Column .................. 4 Footing .................. 5 Drawing .................. 6 Young Electric Sign Company By: Carl Meyers Check: BJ Sign Engineering 3.1 (C) 1998 Young Electric Sign Company 8/9/2004 11:49AM WIND LOADS Project: Charles Schwab Descript: Monument Sign, 5’4” OAH Ref: Uniform Building Code 7997 Basic Wind Speed= 70 mph, UBC figure 16-1 Exposure= C flat terrain, generally open for 1/2 mile. Cq= 1.4 signs, flagpoles and lightpoles, UBC table 16-H Calculation of Design Wind Pressures Height (ft): (qs) (Ce) (Cq) = Wind Pressure 15 20 25 30 40 60 80 100 120 160 200 300 400 12.5 1.06 12.5 1.13 12.5 1.19 12.5 1.23 12.5 1.31 12.5 1.43 12.5 1.53 12.5 1.61 12.5 1.67 12.5 1.79 12.5 1.87 12.5 2.05 12.5 2.19 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 18.6 psf 19.8 psf 20.9 psf 21.6 psf 23.0 psf 25.1 psf 26.9 psf 28.3 psf 29.3 psf 31.4 psf 32.8 psf 36.0 psf 38.5 psf Sign Engineering 3.1 (C) 1998 Young Electric Sign Company SPECIF ICA TIONS Project: Charles Schwab Descript: Monument Sign, 5'4" OAH Steel.. . Design and fabrication according to AISC-ASD, 9th edition. Round pipe: ASTM A53 Grade B or equivalent, Fy = 35 ksi. Machine bolts: ASTM A307 Welding ... Design and fabrication according to AWS DI. 1, current edition. AWS certification required of all structural welders. E70XX electrodes for SMAW processes. F7X-EM electrodes for SAW processes. Concrete ... Design and construction according to ACI 318-95. Compressive strength at 28 days, fc= 2,500 psi minimum. Concrete poured into constrained earth excavations must cure under proper conditions for 4 days prior to sign box installation. ( Exception: if the overall height of the sign is less than 20 feet and the sign pole is adequately braced against wind loads for a minimum of 4 days, the sign box may be installed the same day as the as the footing is poured. ) For pier and caisson footings, concrete must be poured against undisturbed earth. Maintain a minimum 3" concrete cover over all steel embeded in concrete below grade. Sign Engineering 3.1 (C) 1998 Young Electric Sign Company 8/9/2004 11:53AM STEEL COLUMN DESIGN Project: Charles Schwab Descript: Monument Sign, SO" OAH Ref: Manual of Steel Construction, AlSC 9th Edition Areas Subject to Wind Forces Calculation of Design Forces at Critical Heights y (ft) M (#) v (#) y (ft) M (#') v (#) @grade 2,327 931 Column Support Design Table #of Column Column Length Start End Sleeve Sact tb Cols Type Size €lev €lev Depth (e TS) (rt) (rt) (rt) (in) (inA3) (ksi) 1 P 3(.216) 8.75 -3.75 5.00 N/A 1.72 16.2 Allowable Bending Stresses Column Column Criteria Stress increase factor= 1 .OO P 3"( .216) d/t <3300/Fy so ... Fb= 0.66Fy= 23.1 ksi Type Size Sign Engineering 3.1 (C) 1998 Young Electric Sign Company 8/9/2004 11:49AM LATERAL BEARING PIER AND CAISSON FOOTINGS Project: Charles Schwab Descript: Monument Sign, 5'-0" OAH Ref: Uniform Building Code 7997 (Sec. 7806.8) #Footings= 1 MomentlFooting, M= 2,327 Ib-ft Pass lat soil res, q= 200 psf Composite Centroid, h= 2.50 ft Equiv Concentrated Load, P= M/h= 931 Ib Round Caisson Diameter, b= 2.00 ft, round augered hole Depth, D= (A/2)(1+ SQR(1 + (4.36h)/A))= 3.79 ft Actual Depth 4.0 ft S1= (q)(2)(D/3)= 495 psf A= (2.34 P) / (Sl)(b)= 2.20 Concrete Volume Outside Width of Column= 3.5 in Depth of Column in Footing= 3.75 ft Volume of Concrete per Footing= 0.4 cubic yards (+-) Total Order Volume of Concrete= 0.4 cubic yards (+-) Sign Engineering 3.1 (C) 1998 Young Electric Sign Company JOB NO. 144- SHTLOF I DESCRIPTION sescQs UBC 7Omph C L 10' - 0" 1 .= I 3"(.216) PIPE I ASTM A34 B I 8' 4" LONG 0 C U d n 7 d 4 n 4 DETAIL UBC SOIL CLASS 4: -I i /--I ! /-I -1 1 /E++3-4 i I'TCLAYEY SAND I ROUND FOOTING, CONCRETE STRENGTH (NO SPECIAL INSPECTION Ffc'=2500 psi 28 DAYS -I - E REQUIRED) \MAINTAIN 3'1 COVER ON ALL EMB. STEEL 04\Charles Sbwob SCALE : l/2" l'-O'' 9960 dwg Sheet Letter Lost Vodtiied Aug 09. L El Cmino Real 4- -- -sting Charles Schwab 2390Faraday Ave. Carlsbad, CA 92008 q: existin 25’ 265’ \ Faraday