Loading...
HomeMy WebLinkAboutPS 04-185; Sonoma Valley Market; Sign Permits/Programs (PS)I F City of Carlsbad Carlsbad, CA 92008 (760) 602-4600 ** 1635 Faraday Avenue SIGN PROGRAMFEE RECEIPT NO. REVIEW FOR SIGN PERMIT Planning Department All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. 3. 4. 5. Location of existing buildings or structures, parking areas, and vehicular access points to the property. Location of all existing and proposed signs for the property. Distance to the property line($ for all proposed freestanding sign(s). Provide an elevation for all proposed sign(s) which specifies the following: A. B. C. Source of Illumination. D. Proposed sign copy. Dimensions and area for all existing and proposed sign(s). Materials the sign(s) will be constructed of. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:OO P.m. Average processing time: 2 weeks OF PRwi3~: So Mo u- iA - ASSESSOR PARCEL NUMBER 20 3- I 7 4 1 RELATED PLANNING CASE NUMBER(S): TYPE OF DEVELOPMEW. a Residential (e) Service Station (i) Public Park Commercial (0 Prof.Care (j) ProduceStand (h) Govt/Church (1) P-U/OS Zone (c) Officehdustrial (g) Theater (k) Nursery 4% (d) HoteYMotel SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes No 0 Specific Plan Number VILLAGE REDEVELOPMENT AREA Yesd No 0 Requires VR Approval SIGN ORDINANCE: EXISTING SIGNS: p0wL TYPE MAXIMUM NUMBER MAXIMUM NUMBER PROPOSED SIGN ALLOWED AREA Pole Monument \ Wall 6s.a.35 Suspended Directional Canopy Freestanding (Project [dentity) ------ TYPE I NUMBER PROPOSED MAXIMUM PROPOSED SIGN SIGN SIGN AREA HEIGHT HEIGHT c 44 30 ps SIGN AREA I SIGNHEIGHT 1 TYPE MAXIMUM NUMBER MAXIMUM NUMBER PROPOSED SIGN ALLOWED AREA Construction For Sale Banner I I I I I I 4 PROPOSED MAXIMUM PROPOSED SIGN SIGN SIGN AREA HEIGHT HEIGHT Pole . Monument Wall ~~ Suspended ~~ Directional I I t Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes No c] Date PROPOSED PERMANENT SIGNS: PROPOSED TEMPORARY SIGNS: *t*t***ttt***ttt*ttt*t**tt**t**tt*t~ **t Form 10 Revised 01/04 . Page 2 of 3 P EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL, BUILDING STREET FRONTAGE ft. TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) sq. ft. e sq. ft. REUAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN sq. ft. sq. ft. sq. ft. OWNER I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. APPLICANT mok, MAILING ADDRESS QAbd b~\\&q4 Oc TELEPHONE CITYANDSTATE ZIP 'I ,AI f; Cb qZoOg (Uzf)LL(Z-ML I CERTIFY THAT I AM THE REPRESENTATIVE OF THE THAT ALL THE ABOVE INFORMA- CORRECT TO THE BEST OF MY 3. 4. Location: *:+ In right-of-way 5. 6. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. Jn visibility triangle at comer *3 Pole and monument signs to be checked by Traffic Engineering, for visibility issues. When approved route copy to Data Entry APPROVED: Planner: Date: 11 t**t*********ttt*****************t*~*** Form 10 Revised 01/04 Page 3 Of 3 Nov 10 2004 12r5S HP LASERJET 320 - i L /' /--- u P. 2 Fu: 909.944.8081 Fu: 858-527-0440 P.O. Box 26188, Sm Dbm, CA 921%-0188 (858) 527-0330 Offi, (858) 527-0640 Fax @.&&&~,CO~ Q Io I I I I YIyPo. B --+ KI I Aluminum Channel letter slgn(illuminated) I 79' * I 1 Total Size: 1.33' x 22' = 29.25 Square feet sign: @ , SCALE i/21i =ICY Letters mounted to 8" tall x 7" deep x 22' raceway, painted to match building face. Aluminum Channel Letter DETAILS 1. Each letter axlstnrcfedfrMT10.50ted aluminum sheets &coil. Letters to have White interior and Black Exterior. 2. Illuminated by 15 millimeter 6500 Whik neon @ tubing burning at a milliamps. 3. Facescutfrom #507 GREEN acrylicplastic retained by 3/4" trim cap, BLACK in cd~r. yp 4. ~ettersm~lntedtoraceway: with a minimum of 4 bolts 114" X 1" with nutsnockwashers Raceway mounted to wall: With 12 - 318" x 3.3 lag bolts, lagged into structural wood shrds. AU ~RS U.L APPROMD 5. All elecbical interconnections taken through U.L listed ANDMLED conduit to a raceway (if required) or to a transformer box. LOCATED ELEcnucAL ON DISCO"ECT SDE U.L. 2120 Transformers, U.L. listed elecbode caps and OF FIRST LElTER U.L "Sleave Ex' GTO are to be used for connectiarts. System will be connected to an appmved electrical sign arcuit within 10 feet of sign at the time of installation.ln accocdace wlth national electric code. @ landlord approval: SITE PLAN APPROVED E I * a a 6? &3 e e Llc.#737465 s- 1952 Alondra Ct, Ontario Ca. 91764 a DUA ions OR7 c;inc; CAY& ma OAA Rnm I 300 Carsbad Vlllaae Dr. #I07 CITY APPROVAL I DATE d 4 ~~ ~ ~~- I PROJECT TITLE I SCALE I