Loading...
HomeMy WebLinkAboutPS 05-26; Christian Books & Gifts; Sign Permits/Programs (PS)PLANNING DEPARTMENT REVIEW FOR SIGN PERMITS All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: - 1. North arrow and scale. — - 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding signs. 5. Provide an elevation for all proposed signs which specifies the following: A. Dimensions and area for all existing and proposed signs. B. Materials the sign(s) will be constructed of. C. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. Average processing Time: 2 weeksfee S8ts»i&e<$ snor to .- *• «. {"-vS" NAME OF PROJECT: ADDRESS OF PROJECT: ASSESSOR PARCEL NUMBER: RELATED PLANNING CASE NUMBER(S): SIGN TYPE: (d) Real Estate _ (g) Community identity (b) Industrial (e) Freeway _(hX5§rv_jge_ Jtn, Prices (c) Residential (f) Marquee (i) Campaign SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes No SPECIFIC PLAN NUMBER VILLAGE REDEVELOPMENT AREA Yes _ **REQUIRES VR APPROVAL COASTAL ZONE:Yes No ^COASTAL PERMIT Yes No i^FRMOOOlO Page 1 of 2 EXISTING SIGNS: TYPE Pole Monument Wall Suspended Directional Canopy Freestanding (Project Identity) NUMBER SIGN AREA SIGN HEIGHT PERMITS ISSUED FOR EXISTING SIGNS: Yes PROPOSED PERMANENT SIGNS: NoQ Date TYPE Pole** Monument** Wall Suspended Directional Canopy Freestanding** (Project Identity) MAXIMUM NUMBER ALLOWED ±_ NUMBER PROPOSED n_ ,. MAXIMUM SIGN AREA HS PROPOSED SIGN AREA 3M.3 MAXIMUM SIGN HEIGHT rao£ PROPOSED SIGN HEIGHT 5^3 M PROPOSED TEMPORARY SIGNS: TYPE Construction** For Sale** Banner MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT - **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. »«««««»*» Form 10 Revised 12/04 Page 2 of4 •4 f- — - EXISTING SIGNS:Type Number Size (in square feet) (a): Pole _,. (b) Monument (c) WaU PERMITS ISSUED FOR EXISTING SIGNS: Yes No _2SDate TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN O .ft- . sq. ft. . sq. ft. . sq. ft. . sq. ft. . sq. ft. OWNER APPLICANT NAME (PRINT OR TYPE Pn\\\EV ^ ^• " NAME (PRINT OR MAILING ADDRES I MAILING 365(0 CITY AND STATE ZIP TELEPHONE CITY AND STATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE SIGNATURE DATE SIGNATURE DAT Z-/ PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: In right-of-way In visibility triangle at corner On roof 5. Pole and monument signs to be checked by Bob Johnson, Traffic Engineer, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner FRMOOOIO 8/92 -Page 2 of 2 City of Carlsbad 1635 Faraday Avenue Carlsbad CA 92008 Applicant: STANFORD SIGN & AWNING Description Amount PS050026 40.00 Receipt Number: R0048278 Transaction Date: 02/28/2005 Pay Type Method Description Amount Payment Check 5748 40.00 Transaction Amount: 40.00 >J 00°2 01 02 CGP 40-00 48' FRONTAGE- CHRISTIAN BOOKS & GIFTS HEW INTERNALLY ILLUMINATED & NON-ILLUMINATED LETTER DISPLAY SCALE: y.-=1'-0" MANUFACTURE AND INSTALL ONE SET OF INTERNALLY AND NON ILLUMINATED LETTERS. DOVE AND CHRISTIAN LETTERS: REVERSE-RAN CHANNEL LETTERS FACES AND SIDES ARE ALUMINUM PAINTED GLOSS BLACK. ILLUMINATION TO BE 6500 WHITE NEON. BOOKS & GIFTS: W PVC FLAT CUT OUT LETTERS PAINTED GLOSS BLACK FLUSH-MOUNTED TO FASCIA. ,M. NEW LETTERS SCALE: 1/8"=1'-0" VVPVC- STUD MOUNT RUSH- AGAINSTWALL (V«'HN. CLEAR ROW BCTTW SIGH SYSTBTO gQUiRBmrreroB aecTRtCM. nuuimittnoifc PRW1ART ELECTOCAl TO SIGN LOCATIONS 5 TO BE PROVIDE BY OTHERS A DEDICATED CifiCUfTWnH NO SHARED NEUTRALS AND A GROUND RE1URMN3 TO THE PAN& 5 REQUIRED FCR ALL NSTAliAUCNS Required By UL Standard #216? And Western. All Irenstocmers shafl SB. (OR} Orcun0^A-fntsrrup{aa Alt signs have -Dedicated Branch Circuit• Three wires: Line, Neiara & Ground• Wire Size: Mnimum a 12 Qa. THHN Coppsr Wire Alw NctR Gauge tf Wre is deiermlnej tiyira ler^h d run & amperage as per NEC article 3oa• Ground Wre must be ccnDnuos and go Iron the sign to the paneftoard ground bus. • conduit can not be used as ground pan.• Power to sign must be done by a licensed electrician or Electrical contractor. APPROVED INSTALLATION DETAILFLAT CUT OUT LETTERS 1'- V-(T UL APPROVED INSTALLATION DETAIL REVERSE CHANNEL LETTER WITH REMOTE TRANSFORMER 1' = 1'-0n Client signature WEST E/RN p. S ION gjLj "YBTBMa MEMBER OF E' PSOJECT TiTit: CARLSBAD VILUGE CHRISTIAH BOOKS S 6IFTS 540 CARLSBAD VILLAGE PR. CARLSBAD. CA 92008 WESTERN SIQN SYSTEMS 1010 UNDA VISTA DR, SAN MARCOS CA. 92078 PHONE- 760 -736-6070 FAX- 760-736-6073 E-MAIL: saln@wnlrnsign.com PBfSfNTEDBK nFFAlY DEL 6ATTO DMWNSK P.PFOHlBUBTDMBR APPI RCWSIOM D/ITE. 10/07/04 SHEET: 1 OF 2 FILE NUMBER 04-322 ANGELS ARE FROM HEAVEN CO LJLJ £CO THE VILLAGE CORNER LOCATION CARLSBAD VILLAGE DR.