Loading...
HomeMy WebLinkAboutPS 05-67; Starbucks; Sign Permits/Programs (PS)City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-4610 PLANNING APPLICATION #"PS Q5REC'D BY jUiA^ja DATE 5-1 ft- SIGN FEE JEW Q SIGN PROGRAM FEE RECEIPT NO. REVIEW FOR SIGN PERMIT Planning Department All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4;00 p.m. Average processing time: 2 weeks NAME OF PROJECT: ADDRESS OF PROJECT: _ ASSESSOR PARCEL NUMBER: &L / W - RELATED PLANNING CASE NUMBER(S): TYPE OF DEVELOPMENT: (a) Residential fw) Commercial (c) Office/Industrial (d) Hotel/Motel SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA VILLAGE REDEVELOPMENT AREA YesQ SIGN ORDINANCE: YesQ COASTAL ZONE: YesD Form 10 Revised 12/04 Page 1 of 4 (e) (f) (g) 00 Service Station Prof. Care Theater Govt/Church (i) Public Park (j) Produce Stand (k) Nursery (1) P-U/OSZone Specific Plan Number Requires VR Approval No EXISTING SIGNS: TYPE Pole Monument Wall Suspended Directional Canopy Freestanding (Project Identity) NUMBER 3/ '//? / / SIGN AREA - SIGN HEIGHT PERMITS ISSUED FOR EXISTING SIGNS: Yes PROPOSED PERMANENT SIGNS: No Date TYPE Pole** Monument** Wall Suspended Directional Canopy Freestanding** (Project Identity) MAXIMUM NUMBER ALLOWED ? NUMBER PROPOSED 2, li^deniMvg ^ MAXIMUM SIGN AREA ff PROPOSED SIGN AREA /£#JULt 3M>PI MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT PROPOSED TEMPORARY SIGNS: TYPE Construction** For Sale** Banner MAXIMUM NUMBER ALLOWED ^/ '//} / NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. Form 10 Revised 12/04 Page 2 of 4 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument,-and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Traffic Engineering Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. Show building /s P/L \-J.i fi • i * Show all property lines | ; XYJ-1 • ^ i • i •* • • /• S curb line •* , • Sight Visibility 1 i Sight Distance Requirem i 1 how setbacks from all cu I 1 1 Street Name(s) 1 i ent irbs North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. «»»«««»»«»«««««•««»««««« Form 10 Revised 12/04 Page 3 of 4 City of Carlsbad 1635 Faraday Avenue Carlsbad CA 92008 Receipt Applicant: SYMONS JIM Description Amount PS050067 40.00 Receipt Number: R0050030 Transaction ID: R0050030 Transaction Date: 05/18/2005 Pay Type Method Description Amount Payment Check 109731 40.00 Transaction Amount: 40.00 8617 05/18/05 0002 01 02 CGP 40. DONAHUE May 5, 2005 SCHRIBGR STARBUCKS COFFEE COMPANY Attn: Cindy Freels, Seth Parker 17700 Newhope Street, Suite 200 Fountain Valley, CA 92708 Via UPS Overnight # 1Z 8A9 3V9 01 9805 9622 RE: STARBUCKS COFFEE POINSETTIA VILLAGE CARLSBAD, CALIFORNIA Dear Ms. Freels & Mr. Parker: The sign submittal, revised date 4/7/05, for the Starbucks Coffee at our Poinsettia Village center has been reviewed and approved by this office subject to the comments noted on the submittal and described as follows. The original red-lined submittal has been forwarded to Superior Electrical Advertising, your sign contractor, per their request. A copy of the red-lined submittal is enclosed with this letter. 1. All signs shall be reviewed for conformance with the sign criteria and overall design quality and is not a plan check for dimensional errors, code violations or any other restrictions to the property. Approval or disapproval of sign submittals based on aesthetics of design shall remain the sole right of the Landlord/Manager. 2. Prior to the installation and manufacture of any sign, the Tenant shall provide Landlord with a copy of the sign permit from the governmental agency having jurisdiction. 3. Each tenant shall be responsible to repair any damage to any surface caused by the signage or its installation. 4. Landlord reserves the right to periodically hire an independent electrical engineer, at Tenant's sole expense, to inspect the installation of all Tenants' signs. Tenants shall be required to have any discrepancies and/or code violations corrected at Tenant's expense. Any code violations, requests for sign removals, or discrepancies not corrected within fifteen (15) days of notice, may be corrected by the Landlord at Tenant's expense. 5. Upon vacancy, Tenant shall remove sign and restore fascia to original condition at Tenant's sole cost and expense within fifteen (15) days of expiration of term or earlier termination of Tenant's lease. 6. Exposed junction boxes, transformers, lamps, tubing, conduit, raceways or neon crossovers of any type are NOT PERMITTED. 7. Sign manufacturer's names, stamps, or decals may not be visible from the street or normal viewing angles. ,nn c B , c +a a 200 E. Baker Street Suite 100 Costa Mesa, CA 92626 (714) 545-1400 FAX: (714) 545-4222 http://www.donahueschriber.com STARBUCKS COFFEE COMPANY Attn: Cindy Freels, Seth Parker May 5, 2005 Page 2 8. Tenant's sign contractor shall install and connect sign display and primary wiring at sign location approved by Landlord. Signs are to be connected to the J-box provided by the Landlord, which is connected to the Landlord's house panel, and shall be wired to Landlord's control at Landlord's timer for uniform control of hours of illumination unless otherwise directed by Landlord. 9. Tenant shall install service door signage. The purpose of this signage is to identify service door for delivery and emergency purposes only.—Sign shall be XX" (XXXXX inch) high by XX" (XXXXX inch) long shoot metal plaque affixed to the rear door with a minimum of X (XXX) self-tapping sheet metal screws.—Plaque shall be painted to match door color. Letters may be maximum X" (XXXX inches) high. Sign is to be centered on the door with bottom edge located 4'-6" (XX XXX XXX inches) from floor. 10. Prior to sign installation, we require a copy of your sign contractor's insurance certificate naming Donahue Schriber Realty Group, L.P., a Delaware limited partnership, and Poinsettia Associates, a California general partnership, as additional insureds (with additional insured endorsement page attached) and a copy of the permit and the contractor's license. Should any other contractor provide installations or other work on the site, please call Pat Snow, the Property Manager, at (858) 793-5757 or myself at (714) 966-6475 to coordinate insurance requirements. 11. The return and trim cap color shall be painted to match letter color. 12. Signs are to be pegged 1/4" off he face of the wall. 13. Horizontal centerline is to be centered between bottom of rafter tail and the top of the arch and the vertical centerline is to be as depicted on the submittal. 14. Please submit any proposed vinyl lettering for approval. 15. Tenant shall provide listing on applicable Directory sign, per Sign Criteria. Please call me with any questions you may have. Sincerely, DONAHUE SCHRIBER REALTY GROUP, L.P. Clint Knox Project Manager CK:ca Encs. cc: Superior Electrical Advertising, (w/ encs.), via UPS # 1Z 8A9 3V9 01 9797 0639 Pat Snow, Property Manager, DSRG (w/out encs.) File 1700 West Anaheim Street Long Beach, California 90813-1195 phone: 562.495.3808 facsimile: 562.435.1867 www.superiorsigns.com design@superiorsigns.com Project: STARBUCKS COFFEE AVENIDA ENCINAS & POINSETTIA Address: 7130 AVENIDA ENCINAS SUITE E102 CARLSBAD CALIFORNIA / * Account Manager: JIM STERK Designer: JUNE O'NEILL Scale: AS NOTED Design No.: 05-03-5860-05 2.00 Date: 03/11/05 Reg. No.: Revisions: R1 jg 4-7-05 reduce CL to 12'.'/." standoffs. add dim. per sign program R2 jg 6.06.05 delete sign -B'(14' CL) sign "C" (blade sign) is now called sign •B" R3jg 6.09.05 move sign "B" R4 JEO 06/15/05 Remove blade sign R5 JG bnng back one set 14' CL No blade sign VICINITY MAP NORTH Scale: NTS SITE PLAN Of: 05 origin aJiunpublished drawing y Supefer Electrical Advertising fo^your approval It is noi wn lo aflyor* outside of your ion. norfe it to be reproduced, exhibited in any fashion The of colorfe, sizes, materials or 3n melhijfl does not alter the design Ownershipiof this design is held Advertsing. Inc use this design in any fashion must be obtained in writing from Superior Electrical Advertising. Inc ©SEA 2005 Note The Colors depicted here are a graphic representation. Actual colors may vary See color specifications NORTH Scale: NTS SIGN POSITIONS TO BE VERIFIED WITH FIELD SURVEY »,, «-,- ..«' /•'••' /Yu/ . . SITE PLAN 1700 West Anaheim Street Long Beach, California 90813-1195 phone: 562.495.3808 facsimile: 562.435.1867 www.superiorsigns.com design@superiorsigns.com Project: STARBUCKS COFFEE AVENIDA ENCINAS & POINSETTIA Address: 7130 AVENIDA ENCINAS SUITE E102 CARLSBAD CALIFORNIA Account Manager: JIM STERK Designer: JUNE O'NEILL 2.00 Scale: AS NOTED Design No.: 05-03-5860-05 Date: 03/11/05 Reg. No.: Revisions: R1 jg 4-7-05 reduce CL to 12",'// standoffs . add dim. per sign program KL jg 606.05 delete sign "B'(14r CL). sign *C~ (blade sign) is now called sign 'B~ R3jg 6.09.05 move sign "B". R4 JEO 06/15/05 Remove blade sign R5JG bring back one set 14" CL No blade sign Page: 02 Of: 05 This Is an original unpublished drawing created by Superior Electrical Advertising i! is submitted for your approval, if is no! to be shown to anyone outside of your organization, nor is it to be reproduced, copied or exhibited in any fashion. The changing of colors, sizes, materials or illumination method does not alter the design. Ownership of this design is held by Superior Electrical Advertising, Inc Authorization to use this design in any fashion must be obtained in writing from Superior Electrical Advertising. Inc ©SEA 2005 Note: The Colors depicted here are a graphic representation AcSuaf colors may vary See color specifications NORTH Scale: NTS NOTE: VERIFY ALL CONDITIONS AND MEASUREMENTS PRIOR TO FABRICATION STARBUCKSCOFEQ 35'-9 1/2"STARBUCKS LEASE SPACE WEST ELEVATION ONE 12" GREEN FACE LIT CHANNEL LETTERS 16.00 SQ. FT. 1700 West Anaheim Street Long Beach, California 90813-1195 phone: 562.495.3808 facsimile: 562.435.1867 www.superiorsigns.com design@superiorsigns.com ••••^H Project: STARBUCKS COFFEE AVENIDA ENCINAS & POINSETTIA Address: 7130 AVENIDA ENCINAS SUITE E102 CARLSBAD CALIFORNIA Account Manager: JIMSTERK Designer: JUNE O'NEILL 2.00 Scale: AS NOTED Design No.: 05-03-5860-05 Date: 03/11/05 Reg. No.: Revisions: R1 jg 4-7-05 reduce CLto 12".'// standoffs. add dim. per sign program R2 jg 606.05 delete sign -B-(14' CL) sign "C" (blade sign) is now called sign 'B" R3jg 6 09.05 move sign "B". R4 JEO 06/15/05 Remove blade sign R5JG bring back one set 14'CL No blade sign SCALE: 1/8" = 1'Page: 03 Of: 05 This is an original unpublished drawing created by Superior Electrical Advertising II is submitted for your approval. It is not to be shown lo anyone outside of your organization, nor is it to be reproduced, copied or exhibited in any fashion The changing of colors, sizes, materials orillumination method does not alter thedesign. Ownership of this design is heldby Superior Electrical Advertising. IncAuthorization lo use this design in anyfashion musf be obtained in writing fromSuperior Electrical Advertising, tnc ©SEA 2005 Note The Colors depicted here are agraphic representation Actual colorsmay vary See color specifications EQ - ^-v-,-,*-»-^->.-.--, -* ? =» T *—i r^ * * | - » •>-• j. tf- E -?- tl ~W" "T 11 o u STJMIBflCmi r- '—r~"- • "~* '——. I'-O" 20'-0" 60'-7" (V.I.F.) NORTH ELEVATION G) ONE 12" GREEN FACE LIT CHANNEL LETTERS 16.00 SOFT SCALE: 1/8" = 1700 West Anaheim Street Long Beach, California 90813-1195 phone: 562.495.3808 facsimile: 562.435.1867 www.superiorsigns.com design@superiorsigns.com Project: STARBUCKS COFFEE AVENIDA ENCINAS & POINSETTIA Address: 7130 AVENIDA ENCINAS SUITE E102 CARLSBAD CALIFORNIA •".» Account Manager: JIM STERK Designer: JUNE O'NEILL 2.00 Scale: AS NOTED Design No.: 05-03-5860-05 Date: 03/11/05 Reg. No.: Revisions: R1 jg 4-7-05 reduce CL to 12','// standoffs . add dim per sign program R2 jg 6.06.05 delete sign "B"(1<T CL). sign "C* (blade sign) is now called sign V. R3 jg 6.09.05 move sign "B" R4 JEO 06/15/05 Remove Wade sign R5 JG bring back one set 14" CL. No blade sign Of: 0504 This is an original unpublished drawing created by Superior Electrical Advertising It is submitted for your approval. I! is nof to be shown to anyone oulside of your organization, nor is it to be reproduced, copied or exhibited in any fesrti'on. The changing of colors, sizes, materials or illumination method does not alter the design. Ownership of this design is held by Superior Electrical Advertising, inc AulhorizatJon to tsse this design in any fashion must be obtained in writing from Superior Electrical Advertising, inc ©SEA 2005 Noie: The Colors depicted here are agraphic representation Actual colorsmay vary See color specifications. SINGLE LINE FACE-LIT INDIVIDUAL LETTER SPECIFICATION TAG # 5410 / 12"(305mm) LETTER 9'-8"6'-0" All SIGN ELEVATION / INTERNALLY ILLUMINATED GREEN FACE LIT CHANNEL LETTERS PEG MOUNTED OFF WALL QUANTITY: TWO (2) SET REQUIRED SPECIFICATIONS: INTERNALLY ILLUMINATED CHANNEL LETTERS TO BE FABRICATED FROM 0.040 / 3003 ALUMINUM WITH PRE PAINTED WHITE INTERIORS AND PAINTED SATIN FINISH BLACK POLYURETHANE EXTERIORS, 5"(127MM) DEEP. LETTERS BACKS TO BE ALUMINUM POP-RIVETED TO SIDEWALLS AND SEALED. FACES TO BE 3/16"(5MM) WHITE ACRYLIC WITH 1"(25MM) BLACK TRIMCAP RETAINER EDGING. IF GREEN FACES ARE REQUIRED, CENTER OF FACES TO BE 1ST SURFACE 3M SCOTCHCAL #3630-76 HOLLY GREEN VINYL WITH WHITE SHOW THRU SCRATCH BORDERS. INTERNALLY ILLUMINATE LETTERS WITH 30 M.A., DOUBLE-TUBE OF 15mm BRILITE #4500 / EGL 8300 WHITE NEON GLASS. POWER WITH 120V FRANCE TRANSFORMERS. TRANSFORMERS TO BE LOCATED WITHIN REMOTE METAL TRANSFORMER BOX(ES) MOUNTED REMOTELY BEHIND WALL REMOTE TRANSFORMER BOX(ES) TO BE FABRICATED FROM 24 GAUGE SHEET METAL CONSTRUCTION. FASTEN LETTERS PEG MOUNTED VS OFF WALL FOR WATER DRAINAGE. SIGN MUST BE APPROVED BY THE NATIONAL ELECTRICAL CODE, UNDERWRITERS LABORATORY, CUL, AND ALL APPLICABLE LOCAL CODES. I Tag S410 Size Sq.Ft.1 Sq.M.1 Sq.Ft.2 Sq.M.2 12" (305mm) 16.12 1.5 13.76 1.28 Volts Amps | 120 8 1: Figured as one rectangular area 2 : Figured as individual tetter areas Note to All Contractors 1120V Sign Voltage In the utilization of GFI transformers, and in accordance with NEC and UL guidelines, it is required that primary circuits to each sign must have: 1. Dedicated circuits with proper ground from main panel - and must be bonded. a. ANY equipment or lighting that is added/shared to the primary sign circuit will cause GFI transformers to trip "Off". b. Neutral to ground should not exceed 3 volts to prevent GFI from tripping. Not adhering to these specifications will cause electrical outages resulting in costly service calls. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. SCALE: 3/4" = 1'-0" Exposed white border r1/4" 5" Deep channel letter 1" Black Trimcap with square head screws %" Rivet-nut wall attachments or equal as required (4) min. With Vi" standoff. Tube support Aluminum Letter Back 1/2"(13mm)EMT conduit Liquid tight connection — Brilite #4500 / EGL 8300 White 15 mm neon glass Electro bit Double Tube Neon Detail - NTS Disconnect switch in primary to be within sight of sign (sign includes power supply enclosure) REF: NEC 110-3 [B] 600-2, 600-4 Primary electrical source (1/2" conduit minimum) REF: NEC T/ 600-6, 600-21 (by others) Neon Power Pro Neon Sign Cable Prmary Safety Ground Connection i Ltr.Ht. !! Border \ 12"(305mm)3/8"(10mm) IMPORTANT NOTE: NEVER ADD AN INLAY TO THE LETTERS Always use the green letter Wordmark version with the proper inlay already set. To produce white letters, delete green inlay. 3/16" White acrylic with 1st surface 3M vinyl inset Weep Holes @ Bottom Remote transformer box with 30ma, 120v, transformers within 6' of sign. Neon Sign Cable (type NSC/NSC) Alternate cables for this application type NSC and "See General notes at bottom of page Letter - Section View Neon POWER PRO Cable Fitting Installation of Neon Power Pro Neon Sign Cable' UU Listed Sealing Ring Clean surfaces to ensure metal to metal contact N.L. Grounding type locknut or listed grounding ring could be used it enclosure is non-metallic, (i.e. lexan back) 1/2" trade size locknutUL Enclosure with 7/8" hole—/ Wet Side of Enclosure —'' Sealing Ring only required in WET location. All wall penetrations to be sealed with UL Listed silicone sealant Scale n.t.s. ** General notes: Type NSC/NGL Sign Cable - Use UL Listed Liquid-Tight Flexible Cord Connector identified for use with a cord of .390 to .560 inch diameter as marked on the connector or the smallest unit shipping carton. Secure the N.L. end of the cable with the connector. For dry locations, a non- liquid tight UL Listed Flexible Cord Connector may be used. 1700 West Anaheim Street Long Beach. California 90813-1195 phone: 562.495.3808 facsimile: 562.435.1867 www.superiorsigns.com design@superiorsigns.com Project: STARBUCKS COFFEE AVENIDA ENCINAS & POINSETTIA Address: 7130 AVENIDA ENCINAS SUITE E102 CARLSBAD CALIFORNIA Account Manager: JIM STERK Designer: JUNE O'NEILL Scale: AS NOTED 2.00 Design No.: 05-03-5860-05 Date: 03/11/05 Reg. No.: Revisions: R1 j'g 4-7-05 reduce CL to 12".'// standoffs. add dim. per sign program R2 jg 6.06.05 delete sign 'B"(14" CL) sign "C* {biade sign) is now called sign"V. R3jg 6.09.05 move sign 'B' R4 JEO 06/15/05 Remove blade sign R5 JG bring back one sel 14" CL No Wade sign Page: 05 Of: 05 This fe an original unpublished drawing created by Superior Electrical Advertising II is submitted for your approval it is not to be shown to anyone oulside of your organization, nor is it to be reproduced, copied or exhibited in any fashion The changing of colors, sizes, materials or illumination method does no! alter the design. Ownership of this design is held by Superior Etectricaf Advertising, inc. Authorization to use this design in any fashion must be obtained in writing from Superior Electrical Advertising. Inc ©SEA 2005 Note: The Colors depicted here are a graphic representation Actual colors may vary. See color specifications • 1 ••HI IB™ •I AVENIDA ENCINAS & POINSETTA - CARLSBAD. CA {Approved as Noted: D Not Approved!, Returned for Corrections Rosubtnit. Sign to be Pegged Wall VICINITY MAP NORTH Scale: NTS SITE PLAN , Painted Painted Inm Cap to be Returns to be All Installations must Conform to Catena. an\nRD &PV REVISED 1700 West Anaheim Street Long Beach, California 90813-1195 phone: 562.495.3808 facsimile: 562.435.1867 •:'.^^B^^MBI^MMMB^BMi www.superiorsigns.com design@superiorsigns.com Project STARBUCKS COFFEE AVENIDA ENCINAS & POINSETTA Address: 7130 AVENIDA ENCINAS SUITE E102 CARLSBAD CALIFORNIA --'^aSBMi^MM^^M^M^^^BI^^H Account Manager: JIMSTERK Designer: JUNE O'NEILL 2.00 >^'S!EaffiBK^HHn^MMm^^^^H Scale: AS NOTED Design No.: 05-03-5860-01 Date: 03/11/05 Reg. No.: Revisions: R1 jg 4-7-05 reduce CLto 12T, '/.' standoffs, add dim. per sign program 1.50 01 Of: 06 This is an original unpublished drawng created by Superior Beclrical Advertising II is subrritted for your approval. II is nol to be shown to anyone outside oFycur organization, nor is it to be reproduced, copied or exhibited in any fashion. The changing of colors, sizes, materials or illumination meihod does not alter the design. Ownership of this deagn is held by Superior Electrical Advertising, Ire Authorization b use ihs design in any fashion must be obtained in wiling fom Superior Elecfical Advertising, hie ©SEA 2005 Note: The Colors depicted here are a graphic representation. Actual colors may vary See color specifications NORTH Scale: NTS SIGN POSITIONS TO BE VERIFIED WITH FIELD SURVEY \ SITE PLAN 1700WestAnaheimSlreet Long Beach, California 90813-1195 phone: 562.495.3808 facsimile: 562.435.1867 www.superiorsigns.com design@superiorsigns.com Project: STARBUCKS COFFEE AVENIDAENCINAS& POINSETTA Address: 7130AVENIDAENCINAS SUITE E102 CARLSBAD CALIFORNIA Account Manager: JIM STERK r. JUNE O'NEILL 2.00 Scale: AS NOTED Design No.: 05-03-5860-01 Date: 03/11/05 Reg. No- Revisions: R1 jg 4-7-05 reduce CLto 12", %• standofiis, add dim. per sign program 1.50 02 Of: 06 This is an original unpublished drawng created by Superior Electrical Advertising. It is submitted for your approval. Ilisnol lo be shown lo anyone outside of your organization, nor is it to be reproduced, copied or exhibited in any fashion. The changing ofcdors, sizes, materials or illurrinafion melhod does not alter the design. Ownerahip of this design is held by Superior Electrical Advertising, Ire Authorization to use this design in any fashion must be obtabed in writing torn Superior Bectxal Advertising, Inc ©SEA 2005 Note The Colors depicted here are a graphic representation. Actual cobrs may vary. See color specifications NORTH Scale: NTS NOTE: VERIFY ALL CONDITIONS AND MEASUREMENTS PRIOR TO FABRICATION 3'-0"- EQ 16'-0",EQ 3'-0" 7'-5" *fA!*!***!*f«!I!<m£K*mmm*m §r* w«a«(igSfefJ IT tniMNICKi C0PPII i jr. - .J__ > 'wvacwL ^saam \ I j 1 I — | J J 221/2" nf 35'-91/2"STARBUCKS LEASE SPACE I WEST ELEVATION ONE 12" GREEN FACE LIT CHANNEL LETTERS 16.00 SQF ONE 36" ILLUMINATED BLADE SIGN 7.07 SQ FT T SCALE: 1/8" = V 1700 West Anaheim Street Long Beach, California 90813-1195 phone: 562.495.3808 facsimile: 562.435.1867 www. superiorsigns.com design@superiorsigns.com Project: STARBUCKS COFFEE AVENIDAENCINAS& POINSETTA Address: 7130AVENIDAENCINAS SUFTE E102 CARLSBAD CALIFORNIA Account Manager: JIMSTERK Designer JUNE O'NEILL 2.00 Scale. AS NOTED $EOM^HHBHB^B^^^^^ Design No.: 05-03-5860-01 Date: 03/11(05 Reg. No.: Revisions: R1 jg 4-7-05 reduce CL to 12", V standoffs, add dim. per sign program 1.50 03 Of: 06 This is an original unpublished drawing created by Superior Electrical Advertising His submitted for you approval. Ilisnol to be shown to anyone outside of your organization, nor is it to be reproduced, copiedor exhibited in any fashion The changing of colors, sizes, materials or illumination meJhod does not alter the design Ownership of Ihis design is held bySuperior Electrical Advertising, Ire Authorization b use His design in any fashion must be obtained in writing fom Superior Hectical Advertising, Inc ©SEA 2005 Note: The Colors depicted here are a graphic representation. Actual colors may vary. Seecolor specifcalions D 0 O D STARBUCKS €@PPII NORTH ELEVATION 13 ONE 12" GREEN FACE LIT CHANNEL LETTERS 16.00 SQ FT SCALE: 1/8" = 1' 1700 West Anaheim Street Long Beach, California 90813-1195 phone: 562.495.3808 facsimile: 562.435.1867 www.superiorsigns.com design@superiorsigns.com Project. STARBUCKS COFFEE AVENIDA ENCINAS & POINSETTA Address: 7130 AVENIDA ENCINAS SUITE £102 CARLSBAD CALIFORNIA Account Manager: JIM STERK Designer JUNE O'NEILL 2.00 Scale: AS NOTED Design No.: 05-03-5860-01 Date. 03/11/05 Reg. No.: Revisions: R1 jg 4-7-05 reduce CLto 12", 'ff standoffs , add dim. per sign program 1.50 04 Of: 06 This is an original unpublished drawng created by Superior Bectrica1 Advertising. I! is submitted for your approval. II is not to be shown to anyone outside of your organization, nor is it to be reproduced, copied or exhibited in any fashion. The changing of colors, sizes, materials or illumination method does not alter [he design. Ownership of this design is held bySuperiorEteclricatAdvertising, Ire. Authorization b use IHs design in any fashion must be obtained in wiling from Superior Becfrical Advertising, Inc ©SEA 2005 Note: The Colors depicted here are a graphic representation. Actual colors may vary Seecolorspecifications SINGLE LINE FACE-LIT INDIVIDUAL LETTER SPECIFICATION TAG # S410 / 12"(30Smm) LETTER 9'-8"6'-0" TAB AIB SIGN ELEVATION / INTERNALLY ILLUMINATED GREEN FACE LIT CHANNEL LETTERS PEG MOUNTED OFF WALL QUANTITY: TWO (2) SET REQUIRED SPECIFICATIONS: INTERNALLY ILLUMINATED CHANNEL LETTERS TO BE FABRICATED FROM 0.040 / 3003 ALUMINUM WITH PRE PAINTED WHITE INTERIORS AND PAINTED SATIN FINISH BLACK POLYURETHANE EXTERIORS, 5"(127MM) DEEP. LETTERS BACKS TO BE ALUMINUM POP-RIVETED TO SIDEWALLS AND SEALED. FACES TO BE3/16"(5MM) WHITE ACRYLIC WITH 1"(25MM) BLACK TRIMCAP RETAINER EDGING. IF GREEN FACES ARE REQUIRED, CENTER OF FACES TO BE 1ST SURFACE 3M SCOTCHCAL #3630-76 HOLLY GREEN VINYL WITH WHITE SHOW THRU SCRATCH BORDERS. INTERNALLY ILLUMINATE LETTERS WITH 30 M.A., DOUBLE-TUBE OF 15mm BRILITE #4500 / EGL 8300 WHITE NEON GLASS. POWER WITH 120V FRANCE TRANSFORMERS. TRANSFORMERS TO BE LOCATED WITHIN REMOTE METAL TRANSFORMER BOX(ES) MOUNTED REMOTELY BEHIND WALL REMOTE TRANSFORMER BOX(ES) TO BE FABRICATED FROM 24 GAUGE SHEET METAL CONSTRUCTION. FASTEN LETTERS PEG MOUNTED 1/*" OFF WALL FOR WATER DRAINAGE. SIGN MUST BE APPROVED BY THE NATIONAL ELECTRICAL CODE, UNDERWRITERS LABORATORY, CUL, AND ALL APPLICABLE LOCAL CODES. | Tag Size Sq.Ft. 1 S410 12" (305mm) 16.12 Sq.M.1 Sq.Ft.2 Sq.M.2 Volts Amps | 1.5 13.76 1.28 120 8 1: Figured as one rectangular area 2 : Figured as individual letter areas Note to All Contractors 120VJ Sign Voltage In the utffization of GFI transformers, and in accordance rrrtti NEC and UL guidelines, It Is required that primary circuits to each sign must have: 1. Dedicated circuits with proper ground from main panel - and must be bonded. a. AN Y equipment or lighting that Is addedfshared to the primary sign circuit nil cause GFI transformers to trip -OFF". b. Neutral to ground should not exceed 3 volts to prevent GFI from tripping. Not adhering to these specifications will cause electrical outages resulting in costly ! SCALE: 3/4" = 1'-0" Exposed white border 5" Deep channel letter 1" Black Trimcap with square head screws %" Rivet-nut wall attachments or equal as required (4) min. With %" standoff. Tube support Aluminum Letter Back 1/2"(13mm)EMTconduit Liquid tight connection Brilite #4500 / EGL 8300 White 15 mm neon glass Electro bit 3/16" White acrylic with 1 st surface 3M vinyl inset Weep Holes @ Bottom Remote transformer box with 30ma, 120v, transformers within 6' of sign. Neon Sign Cable (type NSC/NSC) Alternate cables for this application type NSC and "See General notes at bottom of page Letter - Section View Double Tube Neon Detail - NTS Disconnect switch in primary to be within sight of sign (sign includes power supply enclosure) REF: NEC 110-3 [B] 600-2, 600-4 Primary electrical source (1/2" conduit minimum) REF: NEC 600-6, 600-21 (by others) Neon Power Pro Neon Sign Cable Prmary Safety Ground Connection LtrHt. I Border 12"(305mm)3/8"(10mm) IMPORTANT NOTE: NEVER ADD AN INLAY TO THE LETTERS Always use the green letter Wordmark version with the proper inlay already set. To produce white letters, delete green inlay. Neon POWER Cable Fitting Installation of "Neon Power Pro Neon Sign Cable" Listed Sealing Ring Clean surfaces to ensure metal to metal contact N.L Grounding type locknut or listed grounding ring could be used If enclosure is non-metallic (i.e. lexan back) 1 /2" trade size locknutUL Enclosure with 7/8" hole- Wet Side of Enclosure • Sealing Ring only required in WET location. THs sign is intended to be installed hi accordance with the Electrical Code and/or other applicable local codes. This bit of Article 600 of the National grounding and bonding at the sign. Scale n.ts. " General notes: Type NSC/NGL Sign Cable - Use UL Listed Liquid-Tight Flexible Cord Connector identified for use with a cord of .390 to .560 inch diameter as marked on the connector or the smallest unit shipping carton. Secure the N.L. end of the cable with the connector. For dry locations, a non- liquid tight UL Listed Flexible Cord Connector may be used. All wall penetrations to be sealed with UL Listed sihcone sealant 1700 West Anaheim Street Long Beach, California 90813-1195 phone: 562.495.3808 facsimile: 562.435.1867 www.superiorsigns.com design@superiorsigns.com Project: STARBUCKS COFFEE AVENIDAENCINAS& POINSETTA Address: 7130AVENIDAENCINAS SUITE E102 CARLSBAD CALIFORNIA •-•'.^•MHBMHHMHHHBMHHHHI Account Manager: JIM STERK Designer: JUNE O'NEILL 2.00 •^•^•••••••••^•^MH^^^H Scale: AS NOTED Design No.: 05-03-5860-01 Date: 03/11(05 ^'^•OMBlMMM^BH^HMHHi^ Reg. No.: Revisions: R1 jg 4-7-05 reduce CLto 12", %" standoffs, add dim. per sign program 1.50 Page: 05 Of: 06 This is an original unpublished drawing created by Superior Eleclricat Advertising. It is submJtied for you approval. Ilisnol to be shown to anyone outside of yourorganization, nor is it to be reproduced,copied or exhibited in any fashion Triechanging of colors, sizes, materials orillurrinafion melhcd does not alter the design. Ownership of (his design is held by-Superior Electrical Advertising, IreAuthorization to use ths design in any fashion must be obtained in wiling fom Superior Elecfrical Advertising, he ©SEA 2005 Note: The Colors depicted here are agraphic representation. Actual colorsmay vary. See color specifications DOUBLE FACE ILLUMINATED LOGO SPECIFICATION TAG # S262 / 36"(914mm) LOGO scale 1/2" = 1'-0" -{ 1/4" THICK PLATE (x) 6" WIDE 6" MOUNTING PLATE PAINTED BLACK !" (X) 4" RECTANGULAR ALUMINUM SUPPORTS PAINTED BLACK o o o o -1/2" RIGID CONDUIT PAINTED BLACK 2" (x) 4" FABRICATED ALUMINUM CHANNEL PAINTED BLACK Base Plate Detail Scale: 1'^r-O" 1700 West Anaheim Street Long Beach, California 90813-1195 phone: 562.495.3808 facsimile: 562.435.1867 www.superiorsigns.com design@superiorsigns.com Project: STARBUCKS COFFEE AVENIDAENCINAS& POINSETTA Address: 7130AVENIDAENCINAS SUITE E102 CARLSBAD CALIFORNIA Account Manager: JIM STERK Designer JUNE O'NEILL 2.00 Scale: AS NOTED Design No.: 054)3-5860-01 Date: 03/11/05 Reg. No.: 7.07 TOTAL SQ. FT. SIGN ELEVATION / MANUFACTURE & INSTALL ONE (1) DOUBLE-FACED INTERIOR-ILLUMINATED P QUANTITY: ONE (1) SIGN REQUIRED CHANNEL LOGO SPECIFICATIONS: LOGO RETURN DEPTH: 4" CUSTOM FABRICATED ALUMINUM CHANNEL LOGO CABINET: 36" DIAMETER CUSTOM FABRICATED ALUMINUM CABINET SIGN TRIMCAP COLOR: 1" BLACK TRIM CAPPING FACES: #7328 WHITE ACRYLIC FACES WITH 1ST SURFACE TRANSLUCENT SCOTCHCAL 3M #3630-76 HOLLY GREEN VINYL OVERLAY. LOGO TO BE 3M #230-22 BLACK VINYL OVERLAY. ALL WHITE TO SHOW THRU WHITE ACRYLIC PLASTIC BACKGROUND RETURNS: PAINTED BLACK SATIN FINISH ILLUMINATION: 15mm BRILITE #4500 / EGL 8300 WHITE , 30 ma, NEON GLASS WITH TRANSFORMERS MOUNTED INTERNALLY CUSTOM BRACKET: PAINTED BLACK TO MATCH CABINET ATTACH: USING ANCHOR BOLTS AS REQUIRED All wall penetrations to be sealed with UL Listed silicone sealant Note to All Contractors Sign Voltage In the utilization of GFI transformers, and in accordance with NEC and UL guidelines, it is required that primary circuits to each sign must have: 1. Dedicated circuits with proper ground from main panel - and must be bonded. a. ANY equipment or lighting that is added/shared to the primary sign circuit will cause GFI transformers to trip "OFF". b. Neutral to ground should not exceed 3 volts to prevent GFI from tripping. Not adhering to these specifications will cause electrical outages resulting in costly service calls. Tag Size Sq.Ft. Sq.M. Volts Amps Trans.Size S262 36" (914mm) 7.07 0.66 120 2.4 9000/30 This sign is intended to be instated hi accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the 9 Revisions: R1 jg 4-7-05 reduce CL to 12", '/.' standoffs, add dim. per sign program 1.50 06 Of: 06 This is an original unpublished drawngcreated by Superior Beclrical Advertising.It is submitted for your approval, it is nolto be shown to anyone outside of yourorganization, nor is it to be reproduced,copied or exhibited in any fashion. Thechanging of colors, sizes, materials orillumination method does nol alter thedesign. Ownership oflhis design is heldby Superior Etecirical Advertising, IreAufoorization to use Iris design in anyfashion must be obtained in witing fromSuperior Electrical Advertising, Inc ©SEA 2005 Note- The Colors depicted here are a graphic representation. Actud colors may vary. See color specificaiions